HUS-HR / HUS-CR Screw anchor

Similar documents
Hilti HUS3 SCREW ANCHOR. Technical Datasheet Update: Oct-18

HUS3 SCREW ANCHOR. Technical Datasheet Update: May-18

HSC UNDERCUT ANCHOR. Technical Datasheet Update: Jul-18

HST-3 EXPANSION ANCHOR. Technical Datasheet Update: Apr-18

HST-3 EXPANSION ANCHOR. Technical Datasheet Update: Apr-18

HUS3-H 8 / 10 / 14 Carbon steel concrete screw with hexagonal head. HUS3-C 8 / 10 Carbon steel concrete screw with countersunk head

HST2 Expansion anchor Everyday standard expansion anchor for cracked concrete

HSA Carbon steel with DIN 125 washer. HSA-R Stainless steel A4 with DIN 125 washer. HSA-R2 Stainless steel A2 with DIN 125 washer

Anchor Fastening. Technology Manual HUS3. Screw Anchor HUS3-H 6/8/10/14 HUS3-C 6/8/10 HUS3-HF 8/10/14 HUS3-A 6 HUS3-I 6 HUS3-P 6 HUS3-PS 6 HUS3

HILTI HSC UNDERCUT ANCHOR. Technical Datasheet Update: Sep-18

HVZ (HVU-TZ+HAS-TZ) adhesive anchor system Anchor design (ETAG 001) / Rods&Sleeves / Concrete

HIT-ICE INJECTION MORTAR. Technical Datasheet Update: Jun-18

Hilti HIT-HY 200 A (R) mortar with HIT-V rods

HDA UNDERCUT ANCHOR. Technical Datasheet Update: Dec-17

HLC. Hex head nut with pressed-on washer HLC-H. Bolt version with washer HLC-L. Torx round head HLC-SK. Torx Counter sunk head HLC-EC

HRD PLASTIC ANCHOR. Technical Datasheet Update: Dec-17

HRD PLASTIC ANCHOR. Technical Datasheet Update: Aug-18

HIT-RE 500 V3 INJECTION MORTAR. Technical Datasheet Update: Dec-17

HKD redundant FLUSH ANCHOR. Technical Datasheet Update: Mar-18

HIT-HY 200 INJECTION MORTAR. Technical Datasheet Update: Dec-17

HIT-HY 200 INJECTION MORTAR. Technical Datasheet Update: Mar-18

HST3 Metal expansion anchor

HIT-HY 200 INJECTION MORTAR. Technical Datasheet Update: Aug-18

HIT-HY 200-A/R INJECTION MORTAR. Technical Datasheet Update: Oct-18

Intended uses of the construction product, in accordance with the applicable harmonized technical specification as foreseen by the manufacturer:

Hilti HIT-RE 500 V3 mortar with HIT-V rod

HIT-HY 170 INJECTION MORTAR. Technical Datasheet Update: Dec-17

HIT-HY 170 INJECTION MORTAR. Technical Datasheet Update: Apr-18

Anchor HSA Fastening. Technology Manual HSA. Stud anchor. Version /

Anchor Fastening Technology Manual. HIT-HY 170 mortar with rebar (as anchor) Hilti HIT-HY 170 mortar with rebar (as anchor) Version

Hilti HIT-RE 10 mortar Economical epoxy mortar for concrete

Hilti HST3 Metal Expansion Anchor

DECLARATION OF PERFORMANCE

HST Carbon steel. HST-R Stainless steel HST-HCR High corrosion resistance steel. Fire resistance

HKD Push-in anchor, Single anchor application

DECLARATION OF PERFORMANCE

HKD Push-in anchor, Single anchor application

Frame fixing SXS-F US

The high-performance frame fixing with SX-technology VERSIONS. zinc-plated steel stainless steel BUILDING MATERIALS

HTR-P / HTR-M Insulation fastener

HRD-U 10 / - S 10 / -U 14 Frame anchor

HRD Frame anchor, Redundant fastening

HVU with HAS/HAS-E rod adhesive anchor system

HKD Push-in anchor, Single anchor application

AC100-PRO. AC100-PRO Vinylester 160ML AC100-PRO Vinylester 300ML AC100-PRO Vinylester 360ML AC100-PRO Vinylester 410ML AC100-PRO 160ML AC100-PRO 300ML

HRD-U 10 / - S 10 / -U 14 Frame anchor

PF18 CHEMICAL ANCHOR CHEMICAL INJECTION SYSTEM

EJOT Concrete screws. ETA-approved concrete screws for cracked and non-cracked concrete

Hilti HIT-CT 1 with HIT-V

DECLARATION OF PERFORMANCE No. HSL-3_B-1109-CPR-0002

SINGLE ANCHOR USE FOR NON-CRACKED CONCRETE

Permissible loads of a single anchor in cracked normal concrete (concrete tension zone) of strength class C20/25 ( B25) Permissible tensile load

Hilti HIT-HY 200-R 500 ml foil pack (also available as 330 ml foil pack) Static mixer

Hilti HIT-HY 170 mortar with HIT-V rod. Anchor Fastening Technology Manual. Hilti HIT-HY 170 with HIT-V HIS-(R)N 03 / /

Universal frame fixing SXR-T

English translation prepared by CSTB - Original version in French language PB-PRO & PB-SS-PRO

Hilti HVU-TZ foil capsule. HAS-TZ HAS-R-TZ HAS-HCR-TZ rod. Shock

DECLARATION OF PERFORMANCE

SIMPLY THE BEST HEAVY DUTY SELF-UNDERCUTTING ANCHOR IN THE WORLD

PRODUCT DATA SHEET SAFETY BOLT

Hilti-HY 110 available in 330ml and 500ml foil packs. Static mixer HIT M1. Rebar BSt 500 S

English translation prepared by CSTB - Original version in French language. Tecfi S.p.A. SS Appia km 193 Pastorano (CE) 81050, Italia

Declaration of Performance

Concrete screw BSZ Steel/steel zinc flake coated

Designated according to Article 29 of Regulation (EU) No 305/2011 and member of EOTA (European Organisation for Technical Assessment)

Hilti HIT-HY 270 mortar for masonry Ultimate performance hybrid mortar for all masonry materials

Internal dry conditions Static or quasi-static loads Seismic actions for Performance Category C1 and C2 Fire exposure

PRODUCT DATA SHEET THROUGH BOLTS S-KA S-KAK S-KAH A4 S-KAH HCR S-KAR A2 HHA A2

European Technical Approval ETA-08/0058

English translation prepared by CSTB - Original version in French language. Injection system Hilti HIT-RE 500 V3

PRODUCT DATA SHEET THROUGH BOLTS. facebook.com/sormat youtube.com/sormatfixing SORMAT Product data sheet 1217

Declaration of Performance No1109-CPD-0080 According to the Regulation EU No 305/2011

Concrete screw BSZ A4

DECLARATION OF PERFORMANCE

M6 M8 M10 M12 M16 M20

English translation prepared by CSTB - Original version in French language. Throughbolt PTB-ETA7-PRO

HDA-P HDA-PR HDA-PF Anchor for presetting. HDA-T HDA-TR HDA-TF Anchor for through-fasting. Nuclear power plant approval

Hilti HIT-HY150 Injection Adhesive with HAS-E/ER/EF/HCR and HIS-N/RN

European Technical Assessment. ETA-12/0398 of 29/12/2017. General Part. Instytut Techniki Budowlanej. Technical Assessment Body issuing the

English translation prepared by CSTB - Original version in French language

HIT-HY 270 INJECTION MORTAR. Technical Datasheet Update: Jul-18

EKSPLOATACINIŲ SAVYBIŲ DEKLARACIJA

Approvals / Certificates:

English translation prepared by CSTB - Original version in French language. Injection system Hilti HIT-RE 500 V3

European Technical Assessment. ETA-11/0336 of 17 July English translation prepared by DIBt - Original version in German language.

Zinc-plated steel Stainless steel Hot-dip galvanised steel BUILDING MATERIALS

Hilti HIT-RE 100 mortar with rebar (as anchor)

1 Input data. Profis Anchor Company: Specifier: Address: Phone I Fax: Page: Project: Fastening Point: Date: 19/04/2016

Declaration of Performance No. DPGEB1006 v2.1

English translation prepared by CSTB - Original version in French language. Simpson Strong-Tie ZAC. Les 4 chemins Sainte-Gemme-la-Plaine France

EJOT Through Bolts. Premium-quality through bolts for fixing in cracked and non-cracked concrete.

R-RBP Rawlbolt - Bolt Projecting for use in cracked and non-cracked concrete

ETA-11/0141 of 08/08/2016. European Technical Assessment. General Part. Technical Assessment Body issuing the. Instytut Techniki Budowlanej

This Technical Assessment meets the testing requirements stipulated in Standards Australia Technical Specification: SA TS101:2015

R-RBL Rawlbolt - Loose Bolt for use in cracked and non-cracked concrete

Declaration of Performance No1109-CPD-0079 According to the Regulation EU No 305/2011 HXE01 - HXE02 - HXE12 - HXE85 - HXE03

Declaration of Performance

Drop-in Anchor E / ES Steel, zinc plated

Drop-in Anchor E / ES Steel, zinc plated

fischer fixing compass Cracked concrete.

Transcription:

HUS-HR / HUS-CR Screw anchor Anchor version Benefits HUS-HR (M8-M14) HUS-CR (M8-M14) - High productivity- less drilling and fewer operations than with conventional anchors - ETA approval for cracked and noncracked concrete - ETA approval for Seismic C1 - Technical data for reusability in fresh concrete (fck,cube = 10/15/20 Nmm 2 ) for temporary applications Base material Load conditions Concrete (non-cracked) Concrete (cracked) Installation conditions Solid brick Autoclaved aerated concrete Static / quasi-static Other information Seismic ETA-C1 Fire resistance Small edge distance and spacing European Technical Assessment CE conformity Corrosion resistance PROFIS Anchor design software Approvals / certificates Description Authority / Laboratory No. / date of issue European Technical Assessment DIBt, Berlin ETA-08/0307 / 2015-08-27 Fire test report DIBt, Berlin ETA-08/0307 / 2015-08-27 Fire test report ZTV Tunel (EBA) MFPA, Leipzig PB III / 08-354 / 2008-11-27 a) All data given in this section according ETA-08/0307 issue 2015-07-27. 1 Oct-17

Static and quasi-static resistance (for a single anchor) All data in this section applies to: - Correct setting (See setting instruction) - No edge distance and spacing influence - Steel failure - Minimum base material thickness - Concrete C 20/25, fck,cube = 25 N/mm² Effective anchorage depth for static Nominal embedment depth hef [mm] 50 a) 60 b) 80 c) 60 a) 70 b) 90 c) - 70 b) 110 c) a) Extra reduced embedment (Hilti Technical Data) b) Reduced embedment depth according to ETA-08/0307. c) Standard embedment depth according to ETA-08/0307. Mean ultimate resistance Non-cracked concrete Tension NRu,m [kn] 12,0 a) 16,0 21,3 16,0 a) 21,3 33,3-25,2 53,6 Shear VRu,m [kn] 31,5 a) 34,7 34,7 41,9 a) 44,0 44,0-50,4 102,7 Cracked concrete Tension NRu,m [kn] 6,7 a) 8,0 16,0 10,0 a) 12,0 21,3-16,0 33,3 Shear VRu,m [kn] 22,5 a) 30,9 34,7 30,0 a) 38,2 44,0-36,0 76,6 a) Hilti Technical Data Characteristic resistance Non-cracked concrete Tension NRk [kn] 9,0 a) 12,0 16,0 12,0 a) 16,0 25,0-18,9 40,2 Shear VRk [kn] 23,6 a) 26,0 26,0 31,4 a) 33,0 33,0-37,8 77,0 Cracked concrete Tension NRk [kn] 5,0 a) 6,0 12,0 7,5 a) 9,0 16,0-12,0 25,0 Shear VRk [kn] 16,9 a) 23,2 26,0 22,5 a) 28,6 33,0-27,0 57,4 a) Hilti Technical Data Design resistance Non-cracked concrete Tension NRd [kn] 5,0 a) 6,7 8,9 6,7 a) 8,9 13,9-10,5 22,3 Shear VRd [kn] 15,7 a) 17,3 17,3 21,0 a) 22,0 22,0-25,2 51,3 Cracked concrete Tension NRd [kn] 2,8 a) 3,3 6,7 4,2 a) 5,0 8,9-6,7 13,9 Shear VRd [kn] 11,2 a) 15,5 17,3 15,0 a) 19,0 22,0-18,0 38,3 a) Hilti Technical Data Oct-17 2

Recommended loads b) Non-cracked concrete Tension NRec [kn] 3,6 a) 4,8 6,3 4,8 6,3 9,9-7,5 16,0 Shear VRec [kn] 11,2 a) 12,4 12,4 15,0 15,7 15,7-18,0 36,7 Cracked concrete Tension NRec [kn] 2,0 a) 2,4 4,8 3,0 3,6 6,3-4,8 9,9 Shear VRec [kn] 8,0 a) 11,0 12,4 10,7 13,6 15,7-12,9 27,3 a) Hilti Technical Data b) With overall partial safety factor for action = 1,4. The partial safety factors for action depend on the type of loading and shall be taken from national regulations. Seismic resistance All data in this section applies to: - Correct setting - Seismic design according to TR045 - The following data are based on ETA-08/0307 issue 2015-08-27 - Concrete C20/25 to C50/60 Effective anchorage depth for seismic C1 Nominal anchorage depth range hnom [mm] 80 90 110 Characteristic resistance for seismic C1 Characteristic tenstion to steel failure Characteristic resistance NRk,s,seis [kn] 34,0 52,6 102,2 Partial safety factor Ms,seis [-] 1,4 Characteristic pull-out resistance in cracked concrete C20/25 to C50/60 Characteristic resistance NRk,p,seis [kn] 7,7 12,5 17,5 Partial safety factor Ms,seis [-] 1,8 Concrete cone resistance and splitting resisance Partial safety factor Ms,seis [-] 1,8 Characteristic resistance for seismic C1 1) Characteristic shear resistance to steel failure Characteristic resistance VRk,s,seis [kn] 11,1 17,9 53,9 Partial safety factor Ms,seis [-] 1,5 Concrete pryout resistance and concrete edge resistance Partial safety factor Mc,seis [-] 1,5 1) Reduction factor gap = 1,0 when using the Hilti Dynamic Set. 3 Oct-17

Fire resistance All data in this section applies to: - Correct setting - No edge distance and spacing influence - Minimum base material thickness - The following technical data are based on: ETA-08/0307 issue 2015-08-27 Nominal embedmenth depth for resistance to fire Type HUS- HR HR HR Nominal anchor. embedmenth depth hnom [mm] 60 80 70 90 70 110 Recommended resistance to fire Type HUS- HR HR HR Steel failure for tension and shear load (F Rec,s,fi =N Rec,s,fi =V Rec,s,fi) Recommended tensile and shear load R30 FRec,s,fi [kn] 9,3 5,0 18,5 41,7 R60 FRec,s,fi [kn] 6,3 3,6 12,0 26,9 R90 FRec,s,fi [kn] 3,2 2,2 5,4 12,2 R120 FRec,s,fi [kn] 1,7 1,5 2,4 5,4 R30 M 0 Rec,s,fi [kn] 8,2 6,3 19,4 65,6 R60 M 0 Rec,s,fi [kn] 5,5 4,6 12,6 42,4 R90 M 0 Rec,s,fi [kn] 2,8 2,8 5,7 19,2 R120 M 0 Rec,s,fi [kn] 1,5 1,9 2,5 8,5 Pull-out failure R30 Recommended ressitance R60 R90 R120 NRec,p,fi NRec,p,fi [kn] [kn] 1,5 1,2 3,0 2,4 2,3 1,8 4,0 3,2 3,0 2,4 6,3 5,0 Concrete cone failure Edge distance R30 to R120 ccr,n [mm] 2hef Spacing R30 to R120 scr,n [mm] 4hef Concrete pry-out failure R30 to R120 k [-] 2,0 2,0 2,0 a) The recommended loads under fire exposure include a safety factor for resistance under fire exposure Ms,fire =1,0 and the partial safety factor for action Ms,fire =1,0. The partial safety factors for action shall be taken from national regulations. Materials Mechanical properties Nominal tensile strength fuk [N/mm 2 ] 870 950 690 Yield strength fyk [N/mm 2 ] 745 815 590 Stressed cross-section As [mm 2 ] 39 55,4 143,1 Moment of resistance W [mm 3 ] 34 58 255 Design bending resistance M 0 Rd,s [Nm] 36 66 193 Oct-17 4

Material quality Part Material Hexagonal head concrete screw Stainless steel (grade A4) Anchor dimensions Anchor size M8 M10 M12 Core diameter dk [N/mm 2 ] 7,05 8,4 12,6 Shaft diameter ds [mm 2 ] 10,1 12,3 16,6 Stressed section As [mm 3 ] 39,0 55,4 143,1 Screw length and thickness of fixture for HUS-HR Embedmenth depth h nom1, h nom2 [mm] 60 80 70 90 70 110 Thickness of fixture t fix1 t fix2 t fix1 t fix2 t fix1 t fix2 Length of screw [mm] 65 5 - - - - - 75 15-5 5 10-80 - - - - - - 85 25 5 15 - - - 90 - - - - - - 95 35 15 25 5 - - 100 - - - - - - 105 45 25 35 15 - - 110 - - - - - - 115 - - 45 25 - - 120 - - - - 50 10 130 - - - - - - 135 - - - - 65 25 140 - - 60 40 - - Screw length and thickness of fixture for HUS-CR Anchor size M8 M10 Embedmenth depth h nom1, h nom2 [mm] 60 80 70 90 Thickness of fixture t fix1 t fix2 t fix1 t fix2 Length of screw [mm] 75 15 - - 5 80 - - - - 85 - - 15-90 - - - - 95 35 15 - - 100 - - - - 105 45 25 35 15 5 Oct-17

Setting information Setting details Type HUS- HR, CR a) HR, CR a) HR Nominal anchorage depth hnom [mm] 50 60 80 60 70 90 70 110 Efective anchorage depth hef [mm] 38 47 64 46 54 71 52 86 Nominal diameter of drill bit d0 [mm] 8 10 14 Cutting diameter of drill bit dcut [mm] 8,45 10,45 14,5 Clearance hole diameter df [mm] 12 14 18 Depth of drill hole h1 [mm] 60 70 90 70 80 100 80 120 Wrench size SW [mm] 13 15 21 Diameter of countersunk head(cr) dh [mm] - 21 - Installation torque Concrete Tinst [Nm] 35 - a) - a) 45 c) 65 Solid m, Mz 12 Tinst [Nm] - b) 16 16 - b) 20 20 - b) - b) Solid m, KS 12 Tinst [Nm] - b) 16 16 - b) 20 20 - b) - b) Aerated concrete Tinst [Nm] - b) 8 8 - b) 10 10 - b) - b) a) Hand setting in concrete base material not allowed ( machine setting only) b) Hilti does not recommend this setting process for this application. c) Installation torque refer to HUS-HR only HUS-HR (hexagonal head) M8,M10 and M14 HUS-CR (countersunk) M8 and M10 Installation equipment Rotary hammer TE 2 TE 30 Drill bit TE-C3X 8/17 TE-C3X 10/22 TE-C3X 14/22 Socket wrench insert S-NSD 13 ½ (L) S-NSD 15 ½ (L) S-NSD 21 ½ (L) Torx (CR type only) S-SY TX 45 S-SY TX 50 - Impact screw driver Hilti SIW 22 T-A Oct-17 6

Setting parameters Nominal anchorage depth hnom [mm] 50 60 80 60 70 90 70 110 Minimum base material thickness hmin [mm] 100 100 120 120 120 140 140 160 Minimum spacing smin [mm] 45 45 50 50 50 50 50 60 Minimum edge distance cmin [mm] 45 45 50 50 50 50 50 60 Critical spacing for splitting failure scr,sp [mm] 114 114 192 166 194 256 187 310 Critical edge distance for splitting failure ccr,sp [mm] 57 71 96 83 97 128 94 155 Critical spacing for concrete cone failure scr,n [mm] 114 114 192 166 194 256 187 310 Critical edge distance for concrete cone failure ccr,n [mm] 57 71 96 83 97 128 94 155 For spacing (edge distance) smaller than critical spacing (critical edge distance ) the design loads have to be reduced (see system design resistance ). Critical spacing and critical edge distance for splitting failure apply only for non-cracked concrete. For cracked concrete only the critical spacing and critical edge distance for concrete cone failure are decidive. Setting instructions *For detailed information on installation see instruction for use given with the package of the product Setting instruction 1. Make a cylinder hole 2. Clean the borehole 3. Install the screw anchor by impact screw driver 4. Ensure that the fixture is caught 7 Oct-17

Basic loading data (for a single anchor) in solid masonry units All data in this section applies to: - Load values valid for holes drilled with TE rotary hammers in hammering mod - Correct anchor setting (see instruction for use, setting details) - The core/material ratio may not exceed 15 % of a bed joint area - The brim area around holes must be at least 70mm - Edge distances, spacing and other influences, see below - All data given in this section according to Hilti Technical Data Nominal embedmenth depth Anchor size M8 M10 Nominal embedmenth depth hnom [mm] 60 70 Recommended loads for HUS-HR / HUS-CR Anchor size M8 M10 Solid clay brick Mz 12/2,0 DIN 105 / EN 771-1 fb a) 12 N/mm 2 Solid sand-lime brick Mz 12/2,0 DIN 106/EN 771-2 fb a) 12 N/mm 2 Aerated concrete PPW 6-0,4 DIN 4165/EN 771-4 fb a) 6 N/mm 2 Tension NRec [kn] 1,0 1,1 Shear NRec [kn] 2,0 2,3 Tension NRec [kn] 0,6 1,0 Shear NRec [kn] 1,1 1,7 Tension NRec [kn] 0,2 0,4 Shear NRec [kn] 0,4 0,9 Permissible anchor location in brick and block walls Edge distance and spacing influence - The technical data for HUS-HR anchors are reference loads for MZ 12 and KS 12. Due to the large variation of natural stone slid bricks, on site anchor testing is recommended to validate technical data - The HUS-HR anchor was installed and tested in center of solid bricks as shown. The HUS-HR anchor was not tested in the mortar joint between solid bricks or in hollow bricks, however a load reduction is expected - For brick walls where anchor position in brick can not be determined, 100 % anchor testing is recommended - Distance to free edge free edge to solid masonry (Mz and KS) units 170mm - Distance to free edge free edge to solid masonry (autoclaved aerated gas concrete) units 170mm - The minimum distance to horizontal and vertical mortar joint (cmin) is started in drawing below - Minimum anchor spacing (smin) in one brick/block is 2*cmin Limits - Applied load to individual bricks may not exceed 1,0 kn without compression or 1,4 kn with compression - All data is for multiple use for non-structural applications - Plaster, graveling, lining or levelling courses are regarded as non-bearing and may not be taken into account for the calculation of embedment depth Oct-17 8