Bottom Hinged Flood Barrier Operation & Maintenance Manual

Similar documents
Pedestrian Flood Door

To Contact PS DOORS:

PEDESTRIAN FLOOD DOOR

SINGLE SWING DOOR PAIRED SWING DOOR

Pallet Gate Installation Instructions and Operators Manual

Installation Instructions/Operation and Maintenance Manual. Models PLG-60 PLG-72. PS DOORS Contact Information. Website psdoors.

To Contact PS DOORS:

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

Installation Instructions/Operation and Maintenance Manual

HATCHSAFE Installation Instructions/Operation and Maintenance Manual Models: All Models

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION A. Product Data: Manufacturer's data sheets on each product to be used, including:

SECTION WATERTIGHT FLOOD PLANKS. A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

SECTION WATERTIGHT DOORS. A. Horizontal Sliding Flood Barrier with frame and hardware.

LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

PAIRED LADDER SAFETY GATE Installation Instructions/Operation and Maintenance Manual

Installation Instructions/Operation and Maintenance Manual

Installation Instructions/Operation and Maintenance Manual

Installation Instructions/Operation and Maintenance Manual

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

PalletPal Low Profile Disc Turntable

SECTION VERTICAL MEZZANINE GATE U.S. Patent No:

SECTION WATERTIGHT GATES & BARRIERS FOR FLOOD & SPILL CONTROL

TrueClean ToteTilter TM

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

BASIC LOUVER INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS

SERIES H2R ACCESS COVER With Retro-Grate

SECTION / STC 52 METAL SOUND CONTROL DOORS

SERIES H1W ACCESS COVER. With Grating Panel

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

SECTION Motor Operated Horizontal Sliding Sound Control Door

Elevation Station MODEL: ES.02-16

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

Mechanical Post Lift. Owner s Manual

BBL-4 FORK-MOUNTED BULK BAG LIFTER USE AND MAINTENANCE MANUAL

BILCO TYPE FR FIRE RATED FLOOR DOOR

SECTION SOUND CONTROL DOORS

Model 5200 Cargo Lift Installation and Operation Manual

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

SERIES W1S & W2S ACCESS COVERS. With Grating Panels

SPECIFICATIONS SECTION FLOOD CONTROL GATES. A. ASTM C 39 - Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens.

SERIES S1R & S2R ACCESS COVERS

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

55-Gallon Tilting Drum Ring

117-Bin Wire Shelf Storage Rack

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

Model 5000 Cargo Lift Installation and Operations Manual

INSTALLATION GUIDE MODELS DMV2402 / DMV3002 / DMV3602

66-Bin Wire Shelf Storage Rack

Installation Instructions For Overly Acoustical / Bullet Resistant Window

Pneumatic PalletPal Level Loader

OPERATION AND MAINTENANCE MANUAL. (For Owner s Use Only)

Model 5200 Cargo Lift Installation and Operation Manual

CYL-LP Series Cylinder Storage Cabinets Assembly and Maintenance Manual

Universal Tactical Light

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE

INSTALLATION GUIDE MODELS DMV2401 / DMV3001 / DMV3601 DMV4801 / DMV6001 / DMV60DS / DMV72DS

AUTOMATIC FOLDING DOOR

Double-Drum Forklift Gripper

OWNERS MANUAL Welcome to the Galaxy Family

RAY-CORE Structural Insulated Roof and Wall Panels

Pallet Puller. Owner s Manual

Aero Tec Models 700 & 750 (115 vac)

SECTION TRANSPARENT BULLET RESISTANT ASSEMBLIES

Model Defibrillator Platform OPERATIONS/MAINTENANCE MANUAL. IMPORTANT Keep manual on file at all times.

Quick-Start Operating Guide Document No Exhaust Fume Hood Copyright 2010 Terra Universal Inc. All rights reserved. Revised September 2010

A M E R I C A N A R C H I T E C T U R A L M A N U F A C T U R E R S A S S O C I A T I O N

SAVE THESE INSTRUCTIONS

SERIES G1A, G1B & G1C SLIDE GATES

Owner s Manual & Safety Instructions

Aluminum Bi-Fold Pet Ramp

MODEL GEK E3 Guard Enclosure Kit. Operator s Manual for Morse Guard Enclosure Kit Model GEK E3 for Can Tumbler Model E3

MODEL GEK E1 Guard Enclosure Kit. Operator s Manual for Morse Guard Enclosure Kit Model GEK E1 for Can Tumbler Model E1

Gun Safe 6720F / 6740F. Operation & Installation Guide. FIRE 30minutes /1100ºF RATED THEFT. Manual # M

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

CDM Network Programmer for CCT100x

Union County Vocational - Technical Schools Scotch Plains, New Jersey

executive safe with Override Key Limited Warranty Operation & Installation Guide Read These Instructions Very Carefully! ENGLISH

Edge-of-Dock Leveler 'BA' - 'BX' Series. Owner s Manual and Installation Instructions

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

Residential Home Limited Warranty

A. OSHA 1910, Subpart D, Fixed Industrial Ladders. C. ANSI A14.3, Safety requirements for Fixed Ladders

RHE3 Dock Leveler Installation Manual

ARCHITECTURAL DESIGN SPECIFICATIONS CRB CRASH BEAM VEHICLE BARRIER. PART I General

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

SECTION / / BULLET RESISTANT SOUND CONTROL WINDOWS

NVD-40 NEAR VERTICAL DRUM LIFTER INSTRUCTION MANUAL

Transcription:

Rev. 091416 Bottom Hinged Flood Barrier Operation & Maintenance Manual Model BH-590 Table of Contents Product Information...2 Inspection & Maintenance...5 Inspection & Maintenance Log...8 Warranty Information...9 PS DOORS Contact Information Mail PS DOORS Attn: PS Flood Barriers 1150 South 48th Street Grand Forks, ND 58201 Local Phone 701.746.4519 Toll Free Phone 877.446.1519 Website www.psdoors.com Email 4psinfo@psdoors.com Hours of Operation 8 A.M. to 5 P.M. CST Monday Friday IMPORTANT! Read entire Instruction and Operations Manual to become familiar with the product. NOTICE This product is a flood protection product. The effectiveness of the product is directly related to the proper installation and operation of this product. Failure to properly maintain this product will affect performance. Publication Notice This manual has been compiled and published covering the latest product descriptions and specifications. The contents of this manual and the specifications of this product are subject to change without notice. PS DOORS reserves the right to make changes without notice in the specifications and materials contained herein and shall not be responsible for any damages (including consequential) caused by reliance on the materials presented, including but not limited to typographical and other errors relating to the publication.

If you need to contact Customer Service Please complete the following information and retain for future reference: Serial Number: Purchase Date: PS DOORS Job Number: Project Name: Safety Precautions The following icons are used throughout this Manual. DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderated injury. NOTICE Indicates manufacturer s statement of additional information. IMPORTANT! Indicates a required action. CRITICAL Indicates a vital component to product performance. Bottom Hinged Flood Barrier; Model BH 590 The BH-590 is a specially designed Bottom Hinged Flood Barrier capable of providing flood protection. The BH-590 is specifically manufactured to meet the opening dimensions and Water Protective Height (WPH) of each customers specific site requirements. DUE TO THE CUSTOM NATURE OF EACH BH-590 FLOOD BARRIER, THEY DO NOT ALL LOOK THE SAME, NOR LATCH OR OPERATE EXACTLY THE SAME. REFER TO INSTALLATION AND CONSTRUCTION DRAWINGS FOR YOUR SPECIFIC INSTALLATION AND OPERATION. Please keep these instructions for later reference and read them before attempting any maintenance or operation of the product. NOTICE Additional Information 1. No additional allowances have been included for hydrodynamic loads, debris impact loads or wave loads, unless specifically detailed in additional documentation provided. 2. All water pressure loads, impact loads, and operating loads are transferred to the building structure. Building structure design, capacity to accept loads from flood barriers, and evaluation of loads applied to structure is by others, not PS DOORS. 3. PS DOORS recommends that the owner implement an regular maintenance and operation testing program to inspect the gaskets and barrier panels. This program may require the replacement of gaskets; touch up painting and accounting for of all the latching devices and proper operation. 4. If the water height exceeds the level of any door penetrations or water protective design height, leakage will occur. 5. This product is equipped with compressible seals, which are not dependent on inflation devices. 6. PS DOORS recommends a flood preparedness plan be developed, trained on, and implemented to be activated during times of potential flooding conditions. 7. PS DOORS AND/OR ITS RESPECTIVE SUPPLIERS MAY MAKE IMPROVEMENTS AND/OR CHANGES IN THE PRODUCT(S) OR SERVICE(S) OFFERED AND/OR THE PROGRAM(S) AT ANY TIME WITHOUT NOTICE. IMPORTANT! Read entire Operations & Maintenance Manual to become familiar with the product. NOTICE This product is a flood protective barrier. The effectiveness of the product is directly related to the proper installation and maintenance of this product. Failure to properly maintain this product will affect performance.

Bottom Hinged Flood Barrier; Model BH 590 IMPORTANT! Read entire Operations & Maintenance Manual to become familiar with the product. Product Description The PS DOORS Bottom Hinged Flood Barrier, Model BH-590 is to be constructed in accordance with PS DOORS standard design, specification, and fabrication methods for Custom Flood Barriers. The following components, in accordance with description provided, are included: 1. Flood Barrier Panel: To be fabricated as a welded structural frame, and sheeted one or both sides with flat sheeting welded in place. Flood door panel to be designed for maximum water height requested above Finished Floor Elevation (FFE). All loads transferred to adjacent structure. This design is subject to a uniformly increasing fluid pressure (hydrostatic pressure loading of water at 62.5 pcf). 2. Flood Barrier Frame: To be of PS DOORS design, for field installation on existing structure and/or embedded within structure. Frame members to be fabricated from structural shapes and formed members. Field grouting is/may be required. 3. Gaskets: To be factory mounted to the flood barrier or frame. Gaskets to be compressible rubber type, field replaceable. 4. Flood Barrier Panel and Frame Finish: Finish on all exposed surfaces to be one of the following: A. Mild steel, one (1) shop coat of manufacturer s standard shop primer (S-W Kemflash Primer E61-R-26), and two (2) coats of Standard Industrial Enamel (S-W Industrial and Marine Coatings B54 Series) applied in accordance with manufacturer recommendations and instructions. (Note: Touch up of finish will be required as scratches will occur during shipment, handling, and installation). B. Aluminum or Stainless Steel, Mill Finish, welds ground not polished. 5. Hardware: To be of appropriate size, type and provided by manufacturer unless noted otherwise. Finish as indicated on drawings. 6. Installation Hardware: PS DOORS includes all sealants, water-stop, anchors, and hardware necessary for installation, latching and retaining flood doors as designed. Note: Anchors are engineered for load design and shall not be changed without factory authorization. 7. Warranty: PS DOORS warrants this product and components to be free from manufacturing defects for a period of one (1) year from date of shipment. See warranty document on page 7 of this document. The following information is available upon request: Structural Calculations: A copy of PS DOORS design calculations by a qualified engineer, to verify the flood barrier s ability to withstand the design loading, is available upon request. The following optional services are available upon request: Optional: Registered professional engineer stamped calculations from within the state or territory where the building will be constructed or substantially improved are available at additional cost. PS DOORS AND/OR ITS RESPECTIVE SUPPLIERS MAY MAKE IMPROVEMENTS AND/OR CHANGES IN THE PRODUCT(S) OR SERVICE(S) OFFERED AND/OR THE PROGRAM(S) AT ANY TIME WITHOUT NOTICE. NOTICE This product is a flood protective barrier. The effectiveness of the product is directly related to the proper installation and maintenance of this product. Failure to properly maintain this product will affect performance.

Bottom Hinged Flood Barrier; Model BH 590 NOTICE Unauthorized modification of this product voids the PS DOORS Limited Product Warranty. Accordingly, you can expect any request for warranty repair to be charged to you, if it requires service after modification. Authorized modifications, received in writing from PS DOORS, as long as the modification is accomplished strictly in accordance with PS DOORS instructions, does not void warranty. To request product modifications contact PS DOORS. I. General Information This manual contains information regarding operation and maintenance of custom water resistant flood barrier assemblies. This product is manufactured to specific guidelines. Unauthorized alteration in any way will result in voiding Factory Warranty, and may cause product to fail. II. Operation Guidelines The following procedures and information are supplied for the operation of the BH-590 Bottom Hinged Flood Barrier assemblies. Operation in a manner other than designed could result in damage or less than acceptable performance at time of need, for which the manufacturer will not be held responsible. Always plan for potential leakage and condensation that can occur during flooding conditions. WARNING The flood protective barrier panels MAY BE heavy, verify panel weights and use appropriate lifting procedures and equipment. III. Safety Precautions A. Flood barriers may operate with or without warning. Precautions must betaken to ensure people are clear of barriers during operation. B. Ensure opening is clear of all obstructions or debris during operation. C. Do not force panels or components if they do not operate freely. D. If removing panels or hardware for maintenance, consult documents for panel weights, and use appropriate hoisting equipment. Protect all gaskets and hardware. Always consult original factory drawings for all installation dimensions, details, hardware, and specifications. - Flood barrier operation could cause severe injury IV. Operation Under Flooding Conditions A. Pre-flooding or Potential Flooding Conditions: 1. At a minimum, conduct Inspection and Maintenance activities as described in this Operations & Maintenance Manual. 2. Ensure BH-590 Hinged Flood Barrier is operational prior to flood waters reaching the opening. B. Flooding Conditions Present: 1. Ensure BH-590 Hinged Flood Barrier is not undeployed at any time when flooding conditions are present. 2. If feasible, check BH-590 Hinged Flood Barrier for leakage or condensation accumulation. CAUTION When placing barrier keep clear of pinch points at all times. C. To Manually Deploy BH-590 For Flooding Condition (without electricity): 1. Clean sill, and jambs of any debris. 2. Locate lift points on face of panel, remove any covers that may be in place. 3. Using proper lifting equipment or appropriate manpower, lift panel into position. 4. Inspect gasket to ensure proper position and compression, if not adjust accordingly.

Bottom Hinged Flood Barrier; Model BH 590 D. To Manually Deploy BH-590 For Flooding Condition (with electricity): 1. Inspect gaskets, repair or replace as needed. 2. Clean sill, and jambs of any debris. 3. Initiate flood gate closing sequence by one of the following methods: a. Locate key switch at opening, insert key and turn b. Locate control panel in utility closet and press close button corresponding to each gate that needs to be deployed. 4. Inspect gasket to ensure proper position and compression, if not adjust accordingly. E. Flood Gates to Automatically Deploy if the Following Conditions Are Present: 1. Buoyant Activation a. If a high water condition occurs, standing flood water will deploy the panel once it has accumulated enough depth inside the pan. 2. Electrical/Sensor Activation a. Provided power is present to the control panel, a high water sensor located inside the flood gate pan will detect standing water and initiate a close sequence through the control panel. The flood gate will then deploy using electrical actuators at each opening. NOTICE PS DOORS recommends all facilities subject to flooding conditions, and employ any type of flood protection have a Flood Preparedness Plan in place for activation prior to, or in times of flooding conditions. IMPORTANT! Consult drawings before replacing fasteners, as most have specific design load requirements. Inspection and Maintenance V. Inspection and Maintenance A. Sills, Frames, and Embedded items: 1. Inspect items for damage and misalignment. Adjust, repair, or replace as needed, to meet original design tolerances. 2. Check all embedded connections, making sure they meet original design standards (refer to original product drawings). B. Fasteners and mechanical connections: 1. All fasteners must be in place and adjusted to their original design standards. Replace any damaged components (refer to original product drawings). C. Sealants: 1. Inspect all sealants used on frames and connections to insure their effectiveness. Replace any cracked, loose, or otherwise non-performing sealants. 2. Use only factory approved/supplied products. D. Gasketing: Check all gaskets around perimeter of opening. 1. Inspect for gasket and corner splice damage, and for continuous adhesion to the attached surface. 2. Visually inspect all gaskets for proper positioning and continuous compression when barrier is deployed. 3. Replace or repair if damage or deterioration to gaskets has occurred. 4. Use only factory approved materials (refer to installation drawings/information). CRITICAL Gaskets are a critical component of the flood protective barrier performance and must meet minimum compression tolerances in the latched position. E. Latching (If required): 1. Operate all latching hardware to ensure smooth, uninhibited movement of all mechanical components. 2. Place flood barrier and check latches for proper engagement. If gaskets are not properly positioned and properly compressed, unlatch barrier panel and adjust latching accordingly.

Inspection and Maintenance Continued F. Finishes: 1. Inspect and clean finishes periodically. 2. Touch-up repair finishes, or refinish as necessary to protect the structural integrity of the product. G. Labels and Placards: 1. Inspect all labels and placards. Replace any labels and placards which are unreadable. H. Housekeeping: 1. Clean sill and jambs of any debris and keep the area clean throughout barrier opening. 2. Keep pan free of debris and ensure barrier can freely rotate into deployed position without impending interference. 3. All gas springs and actuators useful life depends on deployment cycles, local climate, and other factors. Test all components of system prior to potential flood hazards to ensure proper function of system components. 4. PS DOORS recommends simulating flooding conditions within the pan of the BH-590 to test passive buoyancy deployment, electric deployment and water sensor function. Allow sufficient time before potential flooding hazards to replace system components if necessary. WARNING THIS IS A FLOOD PROTECTION BARRIER. NEVER ATTEMPT TO UNDEPLOY BARRIER DURING ANY FLOODING CONDITIONS AS WATER LEAKAGE WILL OCCUR AND YOU MAY NOT BE ABLE TO RECLOSE THE BARRIER. I. Procedure to lower flood barrier into undeployed position: 1. With the BH-590 in the deployed position the barrier can be lowered into the concealed position with a minimum of two people. 2. If the gas spring actuated float assembly is in the upright position it must be reset, or lowered into the bottom of the pan before the flood barrier can be lowered. 3. It may be necessary to manually remove all standing water in the pan to allow the gas spring actuated float assembly to be reset into its lowered position. 4. The panel can then be lowered flush with ground level to complete the procedure. J. Procedure to test buoyant operation: 1. Take precautions to direct pedestrian traffic away from the immediate area of testing. 2. Manually lift barrier open and plug groundwater intake in the pan to enable it to be filled with water. 3. Follow procedure to properly lower barrier into concealed position. 4. Disable electric actuators by turning off power to electric control panel. 5. Use a water supply to fill the pan with water. 6. The barrier will automatically deploy before the water level reaches ground surface level. 7. Unplug groundwater intake to drain the pan. 8. Follow procedure to properly lower barrier into concealed position. 9. It may be necessary to manually remove all standing water to allow the gas spring actuated float assembly to be reset into its lowered position. K. Procedure to test AUTOMATIC-ELECTRIC deployment of barrier: 1. Take precautions to direct pedestrian traffic away from the immediate area of testing. 2. Procedure for testing is specific to each site. PS Doors recommends that the building manager develop a testing procedure to simulate flooding conditions and test the function of the remote water sensor and control system to automatically deploy the flood barrier. 3. Follow procedure to properly lower barrier into concealed position. L. Procedure to test MANUAL-ELECTRIC deployment of barrier: 1. Take precautions to direct pedestrian traffic away from the immediate area of testing. 2. Inspect gaskets, repair or replace as needed. 3. Clean sill, and jambs of any debris.

Inspection and Maintenance Continued 4. Initiate flood gate closing sequence by one of the following methods: a. Locate key switch at opening, insert key and turn. b. Locate control panel in utility closet and press close button corresponding to each gate that needs to be deployed. 5. Inspect gasket to ensure proper position and compression, if not adjust accordingly.

Inspection & Maintenance Log CRITICAL Periodic Inspection and Maintenance Required. Date Purchased: Product: Model Number: Door Identifier / Number: Serial Number: Location: DATE INSPECTED INSPECTED BY (Print & Sign) INSPECTION ITEMS NOTED CORRECTIVE ACTION CORRECTED BY (Print & Sign)

PS DOORS Limited Warranty Limited Warranty - Fill out warranty registration and return to PS DOORS. PS DOORS warrants this product and components to be free from defects in material and workmanship for a period of one (1) year from date of shipment. If within the term of this warranty, any Bottom Hinged Flood Barrier or component is found to be defective upon inspection by an authorized PS DOORS representative, PS DOORS will replace or repair, at PS DOORS discretion, any part found to be defective. Any field labor charges incurred are the sole responsibility of the customer. To make a claim under this warranty, contact PS DOORS at the address shown below. PS DOORS Attention: Warranty 1150 S. 48th Street Grand Forks, ND 58201 Toll Free: 877.446.1519 Phone: 701.746.4519 Fax: 701-746-8340 E-mail: 4psinfo@psdoors.com Unauthorized modification of or to this product voids the PS DOORS Limited Warranty. Accordingly, you can expect any request for warranty repair to be charged to you, if the product requires service after unauthorized modification. Authorized modifications, received in writing from PS DOORS, as long as the modification is accomplished in strict accordance with PS DOORS instructions, does not void warranty. To request product modifications contact PS DOORS, 1150 S. 48th Street, Grand Forks, ND 58201, phone 877.446.1519, email: 4psinfo@psdoors.com. PS DOORS SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES. All other warranty s, express or implied including any warranty of merchantability, are expressly excluded. Some states do not allow the exclusion or limitation of consequential or incidental damages, so the above limitation or exclusion may not apply to you. WARRANTY DOES NOT APPLY TO ANY DAMAGE OR DETERIORATION CAUSED BY MODIFICATION, ABUSE, APPLIED PAINT FAILURE OR FAILURE TO PROVIDE REASONABLE AND NECESSARY MAINTENANCE. This warranty gives you specific legal rights, and you may also have other rights, which vary, from state to state. Exclusions: Gaskets are a wear item and are not covered by the limited warranty. IMPORTANT! ACTION REQUIRED! Warranty Registration - Do not cut this out of the manual. Make a copy. (There is information on the back.) In order to Validate your Warranty the following information must be completed and returned to PS DOORS, failure to completely fill out this information, or to return information to PS DOORS may void warranty. Owner Name: Company: Address: City: State/Providence: Postal Code: Country: Please answer the following questions: 1. has the installed product been tested? Yes No Product: Model: Serial Number(s): Date Installed: Warranty Registration must be returned to: PS DOORS 1150 South 48th Street Grand Forks, ND 58201 Fax: 701.746.8340 Email: 4psinfo@psdoors.com 2. Test witnessed by, Name: Date: 3. Product initial inspection by, Name: Date: Warranty Registration Information will be used for activation of product warranty only.