High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers. The world leader in serving science

Similar documents
A highly sensitive and robust 150 µm column to enable high-throughput proteomics

Next Generation Technology for Reproducible and Precise Proteome Profiling

Simultaneous Quantitation of a Monoclonal Antibody and Two Proteins in Human Plasma by High Resolution and Accurate Mass Measurements

Thermo Scientific Q Exactive HF Orbitrap LC-MS/MS System. Higher-Quality Data, Faster Than Ever. Speed Productivity Confidence

Pushing the Leading Edge in Protein Quantitation: Integrated, Precise, and Reproducible Protein Quantitation Workflow Solutions

Quality Control Measures for Routine, High-Throughput Targeted Protein Quantitation Using Tandem Capillary Column Separation

New Approaches to Quantitative Proteomics Analysis

Improving Retention Time Precision and Chromatography of Early Eluting Peptides with Acetonitrile/Water Blends as Solvent B

Top reasons to upgrade to a Q Exactive HF-X hybrid quadrupole-orbitrap mass spectrometer

for water and beverage analysis

A Highly Accurate Mass Profiling Approach to Protein Biomarker Discovery Using HPLC-Chip/ MS-Enabled ESI-TOF MS

A Complete Workflow Solution for Intact Monoclonal Antibody Characterization Using a New High-Performance Benchtop Quadrupole- Orbitrap LC-MS/MS

ProMass HR Applications!

timstof Pro powered by PASEF and the Evosep One for high speed and sensitive shotgun proteomics

Application Note 639. Daniel Lopez-Ferrer 1, Michael Blank 1, Stephan Meding 2, Aran Paulus 1, Romain Huguet 1, Remco Swart 2, Andreas FR Huhmer 1

Introduction. Benefits of the SWATH Acquisition Workflow for Metabolomics Applications

A Unique LC-MS Assay for Host Cell Proteins(HCPs) ) in Biologics

Increasing Throughput and Efficiency with Exactive LC/MS and Triple Quadrupole LC/MS/MS

timstof Pro with PASEF and Evosep One: Maximizing throughput, robustness and analytical depth for shotgun proteomics

A Novel Screening Method for Anthropogenic Sewage Pollutants in Waste Water, Ground Water and Drinking Water Samples by LC HRAM Analysis

An Integrated Approach to Metabolomics Studies: Discovery to Quantitation on a Single Platform

ProteinPilot Report for ProteinPilot Software

Important Information for MCP Authors

Enabling Systems Biology Driven Proteome Wide Quantitation of Mycobacterium Tuberculosis

Accelerating Throughput for Targeted Quantitation of Proteins/Peptides in Biological Samples

Quantitative LC-MS Analysis of 14 Benzodiazepines in Urine Using TraceFinder 1.1 Software and High Resolution Accurate Mass

Liver Mitochondria Proteomics Employing High-Resolution MS Technology

Spectronaut Pulsar X. Maximize proteome coverage and data completeness by utilizing the power of Hybrid Libraries

Appendix. Table of contents

Thermo Scientific EASY-Spray Technology. Plug-and-spray with. State-of-the-art performance

Využití cílené proteomiky pro kontrolu falšování potravin: identifikace peptidových markerů v mase pomocí LC- Q Exactive MS/MS

Thermo Scientific EASY-nLC 1200 System. Leading in simplicity. and performance

Expand Your Research with Metabolomics and Proteomics. Christine Miller Omics Market Manager ASMS 2017

Confirmatory Determination of Buprenorphine and Norbuprenorphine in Urine Using A High-Throughput LC-HRAM-MS/MS Forensic Methodology

The Importance of High Speed Data Acquisition in the Design and Implementation of GC/MS Applications

Xevo G2-S QTof and TransOmics: A Multi-Omics System for the Differential LC/MS Analysis of Proteins, Metabolites, and Lipids

Thermo Scientific EASY-nLC 1000 System. Effortless, split-free nanoflow UHPLC Top performance in LC/MS

Strategies for Quantitative Proteomics. Atelier "Protéomique Quantitative" La Grande Motte, France - June 26, 2007

Thermo Scientific Solutions for Intact-Protein Analysis. Better, Faster Decisions for. Biotherapeutic Development

Thermo Scientific Proteomics & Metabolomics Seminar Tour

timstof Innovation with Integrity Powered by PASEF TIMS-QTOF MS

Using HRAM Survey Analysis Combined with Rapid MS2 Data to Develop a Fragmentation Based Detection Workflow for Structure ID Acquisition

Generating Automated and Efficient LC/MS Peptide Mapping Results with the Biopharmaceutical Platform Solution with UNIFI

Thermo Scientific Orbitrap Fusion Lumos Tribrid Mass Spectrometer. Breakthrough Gains for Quantitative Biology. Sensitivity Transformed

The Agilent Metabolomics Dynamic MRM Database and Method

Fourier-Transform MS for Top Down Proteomics

Improved Analysis of Biopharmaceutical Samples Using an MS-only Orbitrap Mass Spectrometer

Quantification of Host Cell Protein Impurities Using the Agilent 1290 Infinity II LC Coupled with the 6495B Triple Quadrupole LC/MS System

SGS Delivering Excellence in Compliant Extractables and Leachables Testing

Application Note # ET-20 BioPharma Compass: A fully Automated Solution for Characterization and QC of Intact and Digested Proteins

Jet Stream Proteomics for Sensitive and Robust Standard Flow LC/MS

More Capabilities, New Possibilities in Mass Spectrometry

Monoclonal Antibody Characterization on Q Exactive and Oribtrap Elite. Yi Zhang, Ph.D Senior Proteomic Marketing Specialist Oct.

Supporting Information. Scanning Quadrupole Data Independent Acquisition Part A Qualitative and Quantitative Characterization

Chromatographic Workflows for Biopharmaceutical Characterization

Isotopic Resolution of Chromatographically Separated IdeS Subunits Using the X500B QTOF System

LC/MS Based Quantitation of Intact Proteins for Bioanalytical Applications

Fast and Efficient Peptide Mapping of a Monoclonal Antibody (mab): UHPLC Performance with Superficially Porous Particles

Faster, easier, flexible proteomics solutions

TurboMass GC/MS Software

Proteomics-Based Biomarker Discovery Study in Human and non-human Plasma Using a Two-Pass Workflow

Thermo Scientific EASY-Spray LC Columns Optimization - Red flags to watch for and how to troubleshoot your workflow Estee Toole

See More, Much More Clearly

Proteins. Patrick Boyce Biopharmaceutical Marketing Manager Waters Corporation 1

Rapid Peptide Mapping via Automated Integration of On-line Digestion, Separation and Mass Spectrometry for the Analysis of Therapeutic Proteins

The Overview of LC-MS Quantitative Solutions for Biotherapeutic Analysis

Spectrum Mill MS Proteomics Workbench. Comprehensive tools for MS proteomics

PLRP-S Polymeric Reversed-Phase Column for LC/MS Separation of mabs and ADC

Antibody subunit analysis workflow on a quadrupole-orbitrap mass spectrometer: from optimized sample preparation to data analysis

LTQ Orbitrap XL Hybrid FT Mass Spectrometer Unrivaled Performance and Flexibility

Nano LC at 20 nl/min Made Easy: A Splitless Pump Combined with Fingertight UHPLC Nano Column to Boost LC-MS Sensitivity in Proteomics

: presented at ASMS 2015

Universal Solution for Monoclonal Antibody Quantification in Biological Fluids Using Trap-Elute MicroLC-MS Method

Development and evaluation of Nano-ESI coupled to a triple quadrupole mass spectrometer for quantitative proteomics research

Filter-based Protein Digestion (FPD): A Detergent-free and Scaffold-based Strategy for TMT workflows

Rapid Soft Spot Analysis using the SCIEX Routine Biotransform Solution

iprg-2016 Proteome Informatics Research Group Study: Inferring Proteoforms from Bottom-up Proteomics Data

Analysis of Illegal Dyes in Food Matrices Using Automated Online Sample Preparation with Liquid Chromatography-Mass Spectrometry

For Routine Applications

Targeted and Untargeted Screening of Microcystins in Lake Water Samples Using High Resolution Mass Spectrometry INTRODUCTION

LC-MS workflows for emerging contaminants Dwain Cardona Environmental Marketing Manager, Thermo Fisher Scientific

Parallel LC with Capillary PS-DVB Monolithic Columns for High-Throughput Proteomics

IMPLEMENTATION OF PANORAMA INTO DAILY WORKFLOWS AND QUANTITATIVE PROTEIN PK ANALYSIS IN THE PHARMACEUTICAL SETTING

Key Words Pesticides analysis, food safety, TSQ Endura, TraceFinder, MRL, tsrm, residue analysis

impact Innovation with Integrity Maximum Impact Definitive Answers UHR-TOF MS

Advanced QA/QC characterization MS in QC : Multi Attribute Method

SUPPLEMENTARY INFORMATION

Spectral Counting Approaches and PEAKS

Enhanced Analysis of Host Cell Proteins Using the Agilent 6545XT AdvanceBio LC/Q-TOF

High-throughput capillary-flow LC-MS proteomics with maximum MS utilization

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Multiplexing Two Different Food Residue Methods using HILIC and Reversed Phase Chromatography in the Same LC-MS/MS Run

Understanding life WITH NEXT GENERATION PROTEOMICS SOLUTIONS

Ultra-Sensitive Quantification of Trastuzumab Emtansine in Mouse Plasma using Trap-Elute MicroLC MS Method

Characterization of intact monoclonal antibody with microfluidic chip electrophoresis mass spectrometry

Rapid Peptide Catabolite ID using the SCIEX Routine Biotransform Solution

Supplementary Fig. 1. S-1. Supplementary Fig. 2. S-2. Supplementary Fig. 3. S-3. Supplementary Fig. 4. S-4. Supplementary Fig. 5.

Agilent Software Tools for Mass Spectrometry Based Multi-omics Studies

Analysis of Nucleosides Using an Agilent Infinity II High Speed UHPLC with the 6130 Single Quadrupole Mass Selective Detector

Combination of Isobaric Tagging Reagents and Cysteinyl Peptide Enrichment for In-Depth Quantification

Transcription:

High Resolution Accurate Mass Peptide Quantitation on Thermo Scientific Q Exactive Mass Spectrometers The world leader in serving science

Goals Explore the capabilities of High Resolution Accurate Mass for Peptide Quantitation Balancing the benefits of speed, selectivity, and number of analytes Go through an example of peptide quantitation workflow Discovery-based, data dependent MS for target selection Setting up the targeted SIM (single ion monitoring) or PRM (parallel reaction monitoring) method Data evaluation Tips and tricks for optimal performance Best practice techniques for acquiring reliable data Reference guides for HRAM MS set-up 2

HRAM Peptide Quantitation on Q Exactive Series Mass Specs Q Exactive MS instruments have several key features: High resolution precursor measurements High resolution fragment measurements Efficient precursor window isolation Multiplexing capabilities Targeted quantitation experiment possibilities: Full MS t-sim PRM (with and without MS scan) Untargeted quantitation DIA 3

HRAM Peptide Quantitation on Q Exactive Series Mass Specs Q Exactive MS instruments have several key features: High resolution precursor measurements High resolution fragment measurements Efficient precursor window isolation Multiplexing capabilities Targeted quantitation experiment possibilities: Full MS t-sim PRM (with and without MS scan) Untargeted quantitation DIA 4

An Example HRAM Experiment: Discovery to Quan Top 20 dd-ms2 Screen Database Search Relative Abundance 21.44 100 22.97 90 20.45 80 18.95 17.99 24.16 70 9.09 13.87 14.07 26.78 60 12.12 27.23 50 27.95 40 11.84 29.31 31.23 11.43 30 20 31.51 32.20 10 32.80 37.05 1.56 2.83 6.31 8.64 37.82 0 0 5 10 15 20 25 30 35 4 Time (min) Import.msf file into Skyline software Generate spectral library Peptide Selection Select and refine peptide list in Skyline for proteins you would like to quantify Balance RT windows and number of targets Adjust MS parameters for best cycle time Quan Method RT: 7.97-36.17 23.34 NL: 100 21.44 2.88E8 95 19.66 TIC MS 062916_QE 90 HF_tPRM_3 61prec_1-85 000_fmol_0 27 80 75 14.45 23.39 13.41 20.30 70 22.55 65 60 18.50 14.95 16.63 55 Relative Abundance 50 9.24 16.66 45 40 35.16 17.05 35 35.11 15.98 30 12.20 23.75 30.80 17.08 28.95 25 32.26 34.05 17.19 24.09 20 31.66 33.72 25.52 26.89 15 24.43 11.76 25.98 32.38 10 11.59 27.39 10.88 30.46 32.79 5 29.41 10.71 8.71 0 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time (min) 5

Define the Experiment What are your goals? Are you trying to quantitate 1000 peptides? Is absolute quantitation of only 5 targets your priority? Are you interested in only targeting, or do you also want to survey the sample? There will always be a sacrifice within the targeted experiment Choose the right balance for your experiment Difficulty Experimental Design Speed Precision Sensitivity Accuracy 6

Considerations for Number of Targets As numbers of peptide targets increase: LC method may need to be longer for best separation Affects method throughput Fewer measurements can be made for each target May affect reproducibility, sensitivity and accuracy More targets means RT scheduling Choosing RT window widths and balancing concurrent precursors can be challenging Method Performance Characteristic Speed Precision Sensitivity Accuracy Difficulty Number of Peptide Targets in Method 7

An Example HRAM Experiment: Discovery to PRM Top 20 dd-ms2 Screen Database Search Relative Abundance 21.44 100 22.97 90 20.45 80 18.95 17.99 24.16 70 9.09 13.87 14.07 26.78 60 12.12 27.23 50 27.95 40 11.84 29.31 31.23 11.43 30 20 31.51 32.20 10 32.80 37.05 1.56 2.83 6.31 8.64 37.82 0 0 5 10 15 20 25 30 35 4 Time (min) Import.msf file into Skyline software Generate spectral library Peptide Selection Select and refine peptide list in Skyline for proteins you would like to quantify Balance RT windows and number of targets Adjust MS parameters for best cycle time Quan Method RT: 7.97-36.17 23.34 NL: 100 21.44 2.88E8 95 19.66 TIC MS 062916_QE 90 HF_tPRM_3 61prec_1-85 000_fmol_0 27 80 75 14.45 23.39 13.41 20.30 70 22.55 65 60 18.50 14.95 16.63 55 Relative Abundance 50 9.24 16.66 45 40 35.16 17.05 35 35.11 15.98 30 12.20 23.75 30.80 17.08 28.95 25 32.26 34.05 17.19 24.09 20 31.66 33.72 25.52 26.89 15 11.76 24.43 25.98 32.38 10 11.59 27.39 10.88 30.46 32.79 5 29.41 10.71 8.71 0 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time (min) 8

An Example HRAM Experiment: Discovery to PRM Top 20 dd-ms2 Screen Database Search 100 21.44 22.97 Relative Abundance 90 80 70 60 50 40 30 20.45 18.95 17.99 13.87 24.16 9.09 14.07 26.78 12.12 27.23 27.95 11.84 29.31 31.23 11.43 20 31.51 32.20 10 32.80 37.05 1.56 2.83 6.31 8.64 37.82 0 0 5 10 15 20 25 30 35 4 Time (min) Peptide Selection 9

Example Experimental Design: Data Dependent Acquisition Sample Details Thermo Scientific Pierce HeLa Protein Digest Standard (Part #88328) 0.5 µg/µl Thermo Scientific Pierce Peptide Retention Time Calibration Mixture (Part #88320) Response curve from 25 amol -100 fmol/µl Light versions spiked at a fixed 10 fmol/µl 6 5 LC-MS/MS Peptide Reference Mix (Promega, Madison, WI, Part #V7495) 20 amol 200 fmol/ul MS Qual/Quant QC Mix (Sigma, Saint Louis, MO, Part #MSQC1-1VL) 14 light and heavy peptides at various L:H ratios Thermo Scientific Q Exactive HF Mass Spectrometer Conditions Top 20 data dependent acquisition Full MS resolution: 120k Full MS AGC target: 3e6 MS2 Resolution: 15k MS2 max injection time: 20 ms MS2 AGC target: 1e5 NCE: 27 10

Example LC Conditions EASY-nLC 1000 Trap-Elute configuration Trap column: Thermo Scientific Acclaim PepMap 100 C18 (100 µm ID x 2 cm L, 5 µm particle) Analytical column: Thermo Scientific EASY-Spray C18 (75 µm ID x 25 cm L, 2 µm particle) Gradient A = 2% ACN/0.1% formic; B = 90% ACN/0.1% formic Time per injection: 60 minutes 11

Proteome Discoverer Identifying Peptide Candidates Search discovery data in Thermo Scientific Proteome Discoverer Software Processing workflow 12

Proteome Discoverer Identifying Peptide Candidates Search discovery data in Proteome Discoverer Consensus workflow 13

An Example HRAM Experiment: Discovery to PRM Top 20 dd-ms2 Screen Database Search Relative Abundance 21.44 100 22.97 90 20.45 80 18.95 17.99 24.16 70 9.09 13.87 14.07 26.78 60 12.12 27.23 50 27.95 40 11.84 29.31 31.23 11.43 30 20 31.51 32.20 10 32.80 37.05 1.56 2.83 6.31 8.64 37.82 0 0 5 10 15 20 25 30 35 4 Time (min) Import.msf file into Skyline software Generate spectral library Peptide Selection Select and refine peptide list in Skyline for proteins you would like to quantify Balance RT windows and number of targets Adjust MS parameters for best cycle time Quan Method RT: 7.97-36.17 23.34 NL: 100 21.44 2.88E8 95 19.66 TIC MS 062916_QE 90 HF_tPRM_3 61prec_1-85 000_fmol_0 27 80 75 14.45 23.39 13.41 20.30 70 22.55 65 60 18.50 14.95 16.63 55 Relative Abundance 50 9.24 16.66 45 40 35.16 17.05 35 35.11 15.98 30 12.20 23.75 30.80 17.08 28.95 25 32.26 34.05 17.19 24.09 20 31.66 33.72 25.52 26.89 15 11.76 24.43 25.98 32.38 10 11.59 27.39 10.88 30.46 32.79 5 29.41 10.71 8.71 0 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time (min) 14

An Example HRAM Experiment: Discovery to PRM Import.msf file into Skyline software Generate spectral library Peptide Selection Select and refine peptide list in Skyline for proteins you would like to quantify 15

Evaluate Targets in Discovery Data with Skyline Raw files from discovery experiments can be re-analyzed to observe selected peptides from MS1 data in Skyline Once peptide targets are selected, import discovery data to ensure peptide is detected and to verify RT and isotopic correlation 16

Proteotypic Peptide Selection Refining the List Proteotypic peptides are defined as the peptides that uniquely identify each protein and are consistently observed when a sample mixture is interrogated by a (tandem) mass spectrometer. 1 Key Criteria for peptide selection: Unique sequence for target protein Length of 6-25 amino acids Not too hydrophilic or hydrophobic No PTMs No Missed cleavages Ionizes well Fragments generated are a variety of ions (i.e. not just 3-4 ions) Not too close to N or C terminus (exoproteases) 1. Mallick, P. et al. Nat. Biotechnol. 25, 125 131 (2007). 17

Generating a Q Exactive MS Inclusion List from Skyline Once you have refined your list, you can export the isolation list to set up your PRM instrument method. 18

Generating a Q Exactive MS Inclusion List from Skyline Once you have refined your list, you can export the isolation list to set up your PRM instrument method. Choose your instrument type and make sure to set method type to Scheduled if you have a high number of targets. 19

An Example HRAM Experiment: Discovery to PRM Top 20 dd-ms2 Screen Database Search Relative Abundance 21.44 100 22.97 90 20.45 80 18.95 17.99 24.16 70 9.09 13.87 14.07 26.78 60 12.12 27.23 50 27.95 40 11.84 29.31 31.23 11.43 30 20 31.51 32.20 10 32.80 37.05 1.56 2.83 6.31 8.64 37.82 0 0 5 10 15 20 25 30 35 4 Time (min) Import.msf file into Skyline software Generate spectral library Peptide Selection Select and refine peptide list in Skyline for proteins you would like to quantify Balance RT windows and number of targets Adjust MS parameters for best cycle time Quan Method RT: 7.97-36.17 23.34 NL: 100 21.44 2.88E8 95 19.66 TIC MS 062916_QE 90 HF_tPRM_3 61prec_1-85 000_fmol_0 27 80 75 14.45 23.39 13.41 20.30 70 22.55 65 60 18.50 14.95 16.63 55 Relative Abundance 50 9.24 16.66 45 40 35.16 17.05 35 35.11 15.98 30 12.20 23.75 30.80 17.08 28.95 25 32.26 34.05 17.19 24.09 20 31.66 33.72 25.52 26.89 15 11.76 24.43 25.98 32.38 10 11.59 27.39 10.88 30.46 32.79 5 29.41 10.71 8.71 0 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time (min) 20

An Example HRAM Experiment: Discovery to PRM Balance RT windows and number of targets Adjust MS parameters for best cycle time Quan Method RT: 7.97-36.17 23.34 NL: 100 21.44 2.88E8 95 19.66 TIC MS 062916_QE 90 HF_tPRM_3 61prec_1-85 000_fmol_0 27 80 75 14.45 23.39 13.41 20.30 70 22.55 65 60 18.50 14.95 16.63 55 Relative Abundance 50 9.24 16.66 45 40 35.16 17.05 35 35.11 15.98 30 12.20 23.75 30.80 17.08 28.95 25 32.26 34.05 17.19 24.09 20 31.66 33.72 25.52 26.89 15 11.76 24.43 25.98 32.38 10 11.59 27.39 10.88 30.46 32.79 5 29.41 10.71 8.71 0 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 Time (min) 21

Keys to a Successful Quantitation Experiment Reproducibility!! Reproducibility in retention time Reproducibility in overall signal within replicates Obtaining adequate scans across the peak This is critical for accurate quantitation Tip: 10 scans across the peak for a middle level target will result in enough scans across the peak at your limit of detection Sample complexity Interferences will dictate your limit of detection 22

Keys to a Successful Quantitation Experiment Reproducibility in nanolc Applications Whichever method you choose, optimization of nanolc can improve RT consistency and throughput Short gradients May be optimal for low-complexity samples Throughput can be significantly increased S/N can benefit from sharper, taller chromatographic peaks Ensure you can achieve sufficient separations Ensure you can acquire enough points across the shorter peaks Thermo Scientific UltiMate 3000 RSLCnano System Thermo Scientific EASY-nLC 1000 23

Setting up a Quan Method Questions Before Starting: How wide are my chromatographic peaks? How many targets do I have? What is the complexity of my sample? The answers to these simple questions will greatly impact the design of your targeted instrument method 24

Benefits of HRAM Resolution is the key to selectivity HR/AM targeted peptide quantitation on a Q Exactive MS. Zhang et al., Thermo Scientific Application Note 554 25

Always Think About Total Cycle Time! Thermo Scientific Q Exactive and Q Exactive Plus Mass Spectrometers Resolving Power at m/z 200 Approximate scan speed (Hz) Transient length (ms) Suggested Max Fill Time (ms) 17,500 13 64 50 35,000 7 128 110 70,000 3 256 240 140,000 1.5 512 500 Q Exactive HF MS Resolving Power at m/z 200 Approximate scan speed (Hz) Transient length (ms) Suggested Max Fill Time (ms) 15,000 18 32 20 30,000 12 64 50 60,000 7 128 110 120,000 3 256 240 240,000 1.5 512 500 26

Always Think About Total Cycle Time! 128 ms Total Cycle Time ~1 sec Detection HCD 1 HCD 2 HCD 3 HCD 4 HCD 5 HCD 6 HCD 7 HCD 8 Fill Represents varying fill times with a max IT of 110 ms to match the selected 35K resolution setting Total Cycle time is the length of time it takes to cycle through your entire target list This determines how many scans across the peak are obtained Sufficient amount of data points defines the peak to increase quantitative reproducibility 27

Setting up a Quantitative Method Questions Before Starting: How wide are my chromatographic peaks? How many targets do I have? What is the complexity of my sample? 28

Scheduled or Unscheduled? Q Exactive HF MS Example How many targets? 29

Scheduled or Unscheduled? Q Exactive HF MS Example < 10 How many targets? > 10 Unscheduled method recommended Scheduled method recommended 30

Scheduled or Unscheduled? Q Exactive HF MS Example < 10 How many targets? > 10 Unscheduled method recommended Scheduled method recommended Desired = 10 scans across peak 31

Scheduled or Unscheduled? Q Exactive HF MS Example < 10 How many targets? > 10 Unscheduled method recommended Scheduled method recommended Desired = 10 scans across peak Example: 10 sec wide peaks Example: 20 sec wide peaks 32

Scheduled or Unscheduled? Q Exactive HF MS Example < 10 How many targets? > 10 Unscheduled method recommended Scheduled method recommended Desired = 10 scans across peak Example: 10 sec wide peaks Example: 20 sec wide peaks Total cycle time should be 1 sec Total cycle time should be 2 sec 33

Scheduled or Unscheduled? Q Exactive HF MS Example < 10 How many targets? > 10 Unscheduled method recommended Scheduled method recommended Desired = 10 scans across peak Example: 10 sec wide peaks Example: 20 sec wide peaks Total cycle time should be 1 sec Total cycle time should be 2 sec PRM Method 30K Res (12 Hz) 12 targets at a time t-sim Method 240K Res (2 Hz) 2 targets at a time PRM Method 30K Res (12 Hz) 24 targets at a time t-sim Method 240K Res (2 Hz) 4 targets at a time 34

Scheduled or Unscheduled? Scheduled acquisition increases the number of possible targets Narrow RT windows further increase the number of possible targets Insufficient LC reproducibility can result in lost data if RT windows are too narrow Balance RT window size to maximize number of targets without exceeding desired cycle time 35

Incomplete Scheduling Often, the data-dependent acquisitions can provide accurate retention times Not all targets may be acquired, though, due to interferences Constructing an incomplete scheduled list can help acquire the RTs of those not detected in ddms2 runs The RTs included on the list will mitigate lost cycle time that would result from a completely unscheduled target list Sensitivity for the undetected targets is increased as they are scanned for during each cycle RTs for the previously unscheduled targets can then be added to the targeted list optimizing cycle time to get sufficient sampling across the peak 36

Worst case scenario: too many concurrent precursors RT: 20.00-22.00 Relative Abundance 100 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20.22 20.27 20 20.33 20.84 10 20.10 20.15 20.24 21.78 20.38 20.53 21.75 20.57 20.75 21.02 21.61 21.06 21.19 21.32 21.45 21.49 0 21.82 20.0 20.2 20.4 20.6 20.8 21.0 21.2 21.4 21.6 21.8 Time (min) 21.24 21.29 21.48 21.52 20.52 20.56 20.88 20.93 21.70 21.33 21.66 20.19 20.29 21.20 20.08 20.51 20.36 20.66 20.84 21.09 20.97 21.48 21.53 21.76 21.80 21.13 21.85 20.29 20.89 20.93 20.97 TIC XIC for m/z 773.9 NL: 4.03E8 TIC MS 062916_QEHF_tPRM_361 prec_100-0_fmol_053 NL: 3.95E7 TIC F: FTMS + c NSI Full ms2 773.90@hcd27.00 [106.33-1595.00] MS 062916_QEHF_tPRM_361 prec_100-0_fmol_053 For a 361 precursor method, the 20 minute mark had too many concurrent precursors scheduled, and could only generate ~6 points across the chromatographic peak with a 2 minute RT window. 37

Same data, in Skyline 38

Setting up a Quantitative Method Questions Before Starting: How wide are my chromatographic peaks? How many targets do I have? What is the complexity of my sample? 39

Method Selection Flowchart Background Complexity Low High t-sim Peak Width 5s 20s 10s Max # of Simultaneous Scan Events PRM Peak Width 5s 20s 10s Max # of Simultaneous Scan Events 1 target @ 240k 2 targets @ 120k 2 targets @ 240k 4 targets @ 120k 4 targets @ 240k 8 targets @ 120k 4 targets @ 60k 8 targets @ 30k 8 targets @ 60k 16 targets @ 30k 16 targets @ 60k 32 targets @ 30k Multiplex and/or schedule as needed for # of targets Remember to balance max inject time(s) with transient lengths! 40

Method Selection Flowchart Background Complexity Low t-sim Peak Width 5s 20s 10s Max # of Simultaneous Scan Events 1 target @ 240k 2 targets @ 120k 2 targets @ 240k 4 targets @ 120k 4 targets @ 240k 8 targets @ 120k Multiplex and/or schedule as needed for # of targets 41

Method Selection Flowchart Background Complexity High PRM Peak Width 5s 20s 10s Max # of Simultaneous Scan Events 4 targets @ 60k 8 targets @ 30k 8 targets @ 60k 16 targets @ 30k 16 targets @ 60k 32 targets @ 30k Multiplex and/or schedule as needed for # of targets Remember to balance max inject time(s) with transient lengths! 42

Method Selection Flowchart Background Complexity Low High t-sim Peak Width 5s 20s 10s Max # of Simultaneous Scan Events PRM Peak Width 5s 20s 10s Max # of Simultaneous Scan Events 1 target @ 240k 2 targets @ 120k 2 targets @ 240k 4 targets @ 120k 4 targets @ 240k 8 targets @ 120k 4 targets @ 60k 8 targets @ 30k 8 targets @ 60k 16 targets @ 30k 16 targets @ 60k 32 targets @ 30k Multiplex and/or schedule as needed for # of targets Remember to balance max inject time(s) with transient lengths! 43

HRAM: Sensitivity Gain Through High Resolution and MS2 PRM (t-ms2) provides the same sensitivity as t-sim analysis, but with more selectivity RP 70,000 @ m/z 200 SDLAVPSELALLK m/z 682.40 Urine digest matrix RP 140,000 @ m/z 200 Targeted Proteomic Quantification on Quadrupole Orbitrap Mass Spectrometer Gallien et al., MCP 2012, O112.019802 44

Different Scan Mode Options Quantitation by Full MS t-sim (targeted-selected Ion Monitoring) PRM (Parallel Reaction Monitoring or t-ms2) Combination of MS1 with PRM (both MS1 and MS2 data can be evaluated) All Scan modes utilize high resolution and accurate mass (HRAM) Extract ions with narrow mass window (<5ppm) 45

Global Quantitation: Full MS Complexity: High charge density (AGC 1e6 to 3e6) High resolution across dynamic range (up to 240K on Q Exactive HF MS) Option of acquiring confirmatory MS2 Qualitative Attributes: RT, accurate mass, and isotopic distribution Quantitative Attribute: Peak areas of precursor isotopes 46

Scan Mode: t-sim Use the highest resolution setting to resolve your target from co-eluting species in the isolation window Select number of isotopes for quantitation post acquisition Option of multiplexing (MSX) to maximize cycle time Qualitative Attributes: RT, accurate mass, and isotopic distribution Quantitative Attribute: Peak areas of precursor isotopes 47

t-sim Method Q Exactive HF MS Example 48

t-sim Method Q Exactive HF MS Example These parameters are a good starting point! Highest resolution setting (240K), balanced Max IT (500 ms), 1e5 AGC Target Note: 15 targets are scheduled with 2 peptides/ time segment. At 240K resolution, that is ~2 scans/sec Tip: Reaching max IT is your goal! 49

t-sim Method: Multiplexing Multiplexing (MSX) of t-sim scans can optimize cycle times for quantitation of co-eluting peptides Q Exactive MSX function allows up to 10 precursors to be analyzed in the Orbitrap simultaneously Only one transient required However, each precursor has a separate injection time Thus, we recommend MSX of four or fewer precursors to ensure cycle times remain optimal 50

MSX Functionality and Parallel C-Trap Filling AGC Standard Operation Orbitrap FTMS Acquisition AGC Orbitrap FTMS Acquisition Inject to C-Trap Inject to C-Trap Spectrum Multiplexing AGC Orbitrap FTMS Acquisition AGC Orbitrap FTMS Acquisition Inject to C-Trap Inject to C-Trap Inject to C-Trap Inject to C-Trap Inject to C-Trap Inject to C-Trap Multiplexing Maximizes the Cycle Time of the Q Exactive 51

MSX Functionality and Parallel C-Trap Filling Things to consider When multiplexing, the AGC setting and max IT is for each fill event. Higher order multiplexing require lower max IT (max IT)/(multiplex count) = per target max IT Target Value Recommendations for t-sim (240K Resolution) Targeting without multiplexing (Target Value: 1e5-2e5) Multiplexing 2-5 Targets (Target Value: 1e5) Multiplexing 5-10 Targets: (Not recommended due to fill time/scan time relationship) Spectrum Multiplexing AGC Orbitrap FTMS Acquisition AGC Orbitrap FTMS Acquisition Inject to C-Trap Inject to C-Trap Inject to C-Trap Inject to C-Trap Inject to C-Trap Inject to C-Trap Multiplexing Maximizes the Cycle Time of the Q Exactive MS 52

PRM (t-ms2) Generates high resolution full mass range MS2 spectra Flexibility to choose the specific fragment ions for quantitation post-acquisition Since it is a high resolution scan, you can extract your ion with a narrow ppm mass window achieving high selectivity The Orbitrap analyzer permits parallel detection of all target product ions in one, concerted high resolution mass analysis Qualitative Attribute: RT, fragment accurate mass, and fragment ion ratios Quantitative Attribute: Peak areas of selected fragment ions 53

PRM Method Q Exactive HF MS Example Note: The charge state in the table will affect the applied NCE and the high end of the scan range 54

PRM Method Q Exactive HF MS Example These parameters are a good starting point! 30K resolution with balanced Max IT (50 ms), 1e5 AGC Target Note: 10 targets are not scheduled. At 30K resolution, 0.64s cycle time will generate ~15 scans across a 10 sec FWHM peak 55

NCE Optimization TargetInfusion_100fmolul_300ulmin_769_SIM_MS2 #1625-1668 RT: 1.94-1.99 AV: 44 NL: 1.01E6 T: FTMS + p ESI Full ms2 769.10@hcd27.00 [150.00-1800.00] 385.3424 100 z=1 Relative Abundance TargetInfusion_100fmolul_300ulmin_769_SIM_MS2 #965-990 RT: 1.16-1.19 AV: 26 NL: 1.71E6 T: FTMS + p ESI Full ms2 769.10@hcd17.00 [150.00-1800.00] 385.3424 100 z=1 464.7297 z=2 Relative Abundance 80 60 40 20 0 80 60 40 20 0 209.1647 z=1 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 m/z 209.1647 z=? 237.1599 z=? 322.3104 z=1 322.3106 z=1 386.3454 z=1 480.1869 z=1 524.4410 z=1 842.3951 z=2 z=1 960.9708 z=2 1376.8217 z=1 621.4956 465.2315 z=2 760.8632 465.7321 z=2 621.4956 z=1 696.3412 z=2 688.9158 z=2 760.8622 z=2 928.4532 z=1 799.4097 z=1 829.3857 z=? 929.4546 z=1 930.4582 z=1 1041.5367 z=1 1100.6739 z=1 1204.5980 z=1 1263.7400 z=1 z=2 843.3969 961.4737 z=2 z=2 1263.7357 z=1 1100.6762 z=1 1391.6703 z=1 1520.7134 z=1 1505.8632 z=1 NCE = 27% Typical setting used for global peptide identification 1683.7815 z=1 NCE = 17% Setting used to achieve maximum sensitivity 1683.7792 z=1 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 m/z 56

NCE Optimization 57

NCE Optimization NCE = 19 NCE = 25 58

NCE Optimization NCE = 19 NCE = 25 NCE = 19 NCE = 21 NCE = 23 NCE = 25 59

Isolation Window Optimization Triplicate injections at each isolation width 0.7 m/z iso 0.4 m/z iso 1.2 m/z iso Narrower isolation widths reduce interferences, but may compromise sensitivity 60

Isolation Window Optimization Triplicate injections at each isolation width 0.4 m/z iso 0.7 m/z iso 1.2 m/z iso Interferences in the 1.2 m/z isolation window prevents target detection 61

Example: Quantitation using PRM Peak areas are calculated from the extracted ion chromatograms of parent fragment ion JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60mi... 11/20/13 12:08:35 50ng HeLa + 10fmol PRTC JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60min_01 #7822 RT: 32.38 AV: 1 NL: 2.15E6 F: FTMS + p NSI Full ms2 773.90@hcd28.00 [100.00-1600.00] 215.1392 100 Relative Abundance 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 0 299.1716 384.2328 497.3170 615.3174 660.3824 761.4282 876.4550 975.5262 1032.5466 1119.5782 1231.6125 1304.6576 200 400 600 800 1000 1200 1400 1600 m/z [M+2H] 2+ of ELGQSGVDTYLQTK[ 13 C 6 15 N 2 ] RT: 30.93-33.72 SM: 7G Relative Abundance 100 80 60 40 20 0 100 80 60 40 20 0 100 80 60 40 20 0 100 80 60 40 20 0 100 80 60 40 20 MA: 4496620 MA: 14299637 MA: 9837574 MA: 11533285 MA: 40330952 MA: 4496620 SN: INF MA: 14299637 SN: INF MA: 9837574 SN: INF MA: 11533285 SN: INF MA: 40330952 SN: INF 0 31.0 31.5 32.0 32.5 33.0 33.5 Time (min) NL: 6.10E5 m/z= 1304.6507-1304.6637 F: FTMS + p NSI Full ms2 773.90@hcd28.00 [100.00-1600.00] MS JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60min_01 773.90 1304.65 NL: 1.85E6 m/z= 1119.5728-1119.5840 F: FTMS + p NSI Full ms2 773.90@hcd28.00 [100.00-1600.00] MS JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60min_01 773.90 1119.57 NL: 1.29E6 m/z= 1032.5406-1032.5510 F: FTMS + p NSI Full ms2 773.90@hcd28.00 [100.00-1600.00] MS JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60min_01 773.90 1032.54 NL: 1.54E6 m/z= 876.4505-876.4593 F: FTMS + p NSI Full ms2 773.90@hcd28.00 [100.00-1600.00] MS JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60min_01 773.90 876.45 NL: 5.26E6 m/z= 876.4505-876.4593+1032.5406-1032.5510+ 773.90 876.45, 1032.54, 1119.57, 1304.65 1119.5728-1119.5840+1304.6507-1304.6637 F: FTMS + p NSI Full ms2 773.90@hcd28.00 [100.00-1600.00] MS JH_20Nov13_EZ_50ngHeLa_tMS2_25cm_60min_01 62

Example: Skyline PRTC Peptide SSAAPPPPPR 63

Summary You have options when deciding which instrument method to use. Pick which one best suits your needs. Full MS t-sim Low complexity PRM (t-ms2) High complexity Deciding on how many targets you want to go after will greatly affect your experiment set up Number of targets will affect: Scheduled vs unscheduled Retention time windows, if scheduled Scanning resolution The complexity of your sample will also affect your experiment set up: Resolution Maximum injection times 64

Tips, Tricks and Troubleshooting Help The world leader in serving science

Order of Operations (example of 5 targets) Type and number of experiment nodes will affect how the instrument scans Scan 1: MS2 of target 1 Scan 2: MS2 of target 2 Scan 3: MS2 of target 3 Scan 4: MS2 of target 4 Scan 5: MS2 of target 5 Scan 6: MS2 of target 1 Scan 1: Full MS Scan 2: MS2 of target 1 Scan 3: Full MS Scan 4: MS2 of target 2 Scan 5: Full MS Scan 6: MS2 of target 3 Etc. 66

Order of Operations (example of 5 targets) Type and number of experiment nodes will affect how the instrument scans Scan 1: Full MS Scan 2: MS2 of target 1 Scan 3: MS2 of target 2 Scan 4: MS2 of target 3 Scan 5: MS2 of target 4 Scan 6: MS2 of target 5 Scan 7: Full MS Scan 8: MS2 of target 1 Etc. 67

Order of Operations (example of 40 targets) Type and number of experiment nodes will affect how the instrument scans Scan 1: Full MS Scan 2: MS2 of target 1 Scan 3: MS2 of target 2 Scan 4: MS2 of target 3 Scans 5 40: MS2s of targets 4 39 Scan 41: MS2 of target 40 Scan 42: Full MS 68

Method Optimization Are you reaching max IT @ apex? No Yes Is your target low level? Do you have 10 scans across your peak? No Adjust timing or increase msx No Yes All is well! Yes Troubleshoot for low level target Did you detect your target? No Yes Increase AGC if <2E5 and/or troubleshoot interference Troubleshoot interference Did you detect your target? No All is well! Yes Do you have 10 scans across your peak? Yes No Decrease max IT or AGC if >1E5 69

Method Troubleshooting Interference in your isolation window? Decrease isolation width Switch from t-sim to t-ms2 Adjust gradient conditions Target is low level and close to limit of detection? If you are reaching target value, increase target to 2e5 If you are not reaching target, then increase max IT as high as peak width allows Play close attention to the timing of your targets. If you have very reproducible RT, then try to narrow your time segments which can allow you to increase your max IT. 70

Acknowledgements Tara Schroeder Josh Nicklay Susan Abbatiello Brad Groppe Kent Seeley Katie Southwick Scott Peterman Yue Xuan 71

Where to get help! Technical Support-North America Priority issues: Call 800-532-4752, Select option 2 Non-urgent issues: Webform: http://www.unitylabservices.com/contact.php Email: US.Techsupport.Analyze@ThermoFisher.com Enter serial number in subject line Provide brief Description of Issue Technical Support-Europe Email:EU.techsupport.CMS@thermofisher.com 72