NITEC CRYSTAL 1. Elektrolyt to achieve uniform and non reflective Nickel deposits

Similar documents
DURNI-COAT DNC

SurTec 759 Acidic Bright Zinc Process

SurTec 717 Alkaline Zinc/Nickel Electroplating Process (Electrolyte based on Sodium)

SurTec 712 Alkaline Cyanide-Free Zinc/Iron Process

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

SurTec 704 Cyanide-Free Alkaline Bright Zinc Process of the New Generation

SurTec 704 Cyanide-Free Alkaline Bright Zinc Process of the New Generation

Tinmac Stannolyte Bright Acid Tin Solution

Lead free electroless plating nickel bath for high wear resistant applications

TriPass ELV 1500LT Iridescent Trivalent Chromium Passivate

Lead-free electroless plating nickel bath for high wear and corrosion resistant applications

Manufactured for North America exclusively by Automated Chemical Solutions, Inc E. Roeser Road Phoenix, Arizona 85040

HAVALLOY Z-C ACID CHLORIDE ZINC / COBALT PROCESS

SurTec 717 R Alkaline Zinc/Nickel Process

TECHNICAL DATA SHEET CUPROBRITE Revolutionary & New generation Bright Acid Copper Plating Process

SurTec 881 Trivalent Decorative Chromium Process

SILVERON TM GT-101 Bright Silver Cyanide-Free Bright Electrolytic Silver For Electronic, Decorative and Industrial Finishing Applications

Lumina. Bright, leveled deposits in less time Excellent ductility Good chromium reception Very low additive consumption rate. Nickel Plating System

NON-CYANIDE ZINC NICKEL PROCESS

NICKEL GLEAM BR 220 BRIGHT NICKEL PROCESS

NB SEMIPLATE AG 100 Ag electroplating process

Immersion Tin SN 30 1

Bright Tin CULMO 20. Bright Tin CULMO 20 is extraordinary stable and easy to handle.

SurTec 609 EC Pre-Treatment prior to E-Coat

COPPER GLEAM RG 11 Acid Copper Plating Process

NiClipse. Zinc Alloy Plating NiClipse

Enerox Nickel Additive E 66 Product Code: Revised Date: 02/28/2012. Enerox Nickel Additive E 66 High End Rack Plating

4831 S. Whipple Avenue Chicago IL Phone: Fax:

Alkzinc 818. Mirror bright finish Good zinc deposit distribution Very good adhesion and ductility Excellent chromate receptivity

4831 S. Whipple Avenue Chicago IL Phone: Fax:

NiClipse C. Ammonium chloride free

HyProTec. Hexavalent free RoHS, ELV and WEEE compliant. HyPro System

RONOVEL C AUROSPEED CVD

AURALL 305M Electrolytic Gold For Electronic Finishing Applications

High Throw Bright Acid Copper for Rack and Barrel Plating

COMPLETE BARREL. ZINC PLATING SYSTEMS ZCl K3 MAINTENANCE

PALLAMET 500 Palladium-Nickel

DE-88K. Ammonia free Temperature tolerance up to 110 F (43 C), reducing cooling costs. Zinc Plating System

HAVACHROME CR3 TRIVALENT BRIGHT CHROMIUM PROCESS

PavCoTing. Chromium appearance and corrosion resistance Ease of plating bath control Wide current density range

Enerox Nickel Additive E 44 Product Code: Revised Date: 09/26/2007

NON-CYANIDE ZINC-IRON PROCESS ZI NF E R S

PALLAMERSE SMT 2000 For PWB Metallization Applications

Brass Plating Process

SILVER GLO 3KBP. With SILVER GLO 33BP Silver Plating Process For Electronic Finishing Applications. Silver M etal as Silver: Cyanide (80.

NB SEMIPLATE AU 100 Bright Au electroplating process, sulfite based, arsenic grain refiner

Non-Cyanide Alkaline Silver Plating

SOLDERON SC Process. For Electronic Finishing Applications. Deposits meet or exceed Military Specification Method 202F, Method 208F.

Luster-On Products. Technical Data Sheet LUSTER-ON CADMIUM SPECIAL

NB SEMIPLATE CU 150 Copper electroplating process

Zinc Alloy Plating Ziniloy

Metal Finishing Products and Service META-MATE ZINCATE 40 "A CONCENTRATED LIQUID ZINCATE FORMULATION FOR THE PRETREATMENT OF ALUMINUM AND ITS ALLOYS"

NB SEMIPLATE AU 100 TH Bright Au electroplating process, sulfite-based, arsenic-free

SurTec 680 Chromiting Chromitierung

P.T. SINAR CEMARAMAS ABADI

CIRCUPOSIT 71 Full Build Electroless Copper Nitrate Bath (Generic Concentrates) For Electronic Finishing Applications

CHAPTER 3 DEVELOPMENT OF ELECTROPLATING SETUP FOR PLATING ABS AND POLYAMIDES

TECHNICAL DATA SHEET GARDOBOND G 4040

Technical Process Bulletin

ZCl K3. Ammonia free Temperature tolerance up to 110 F (43 C), reducing cooling costs. Zinc Plating System

Ultrex EDM Product Code: Revised Date: 07/26/2006. Ultrex EDM Heavy Duty Alkaline Product Derusting - Descaling - Activation

Laser EX 50 Product Code: Revised Date: 03/17/2009. Laser EX 50

TINGLO CULMO Bright Acid Tin Electroplating (with Starter/Brightener 2.5X) For Electronic Finishing Applications

-.O oz/gal. It is again desirable to have some means of mechanical agitation.

Ultrex CAA Product Code: Revised Date: 10/09/2006. Ultrex CAA Heavy Duty Alkaline Product Derusting - Descaling - Activation

NIPOSIT PM-980 W Semi-Bright Electroless Nickel Process For Industrial Finishing Applications

E-Brite 30/30. Non-Cyanide Alkaline Copper Plating

ELECTRONIC GRADE SULFAMATE NICKEL Document ID: EFM1409

Technical Data Sheet. Physical Specifications

NB SEMIPLATE CU 200 Copper electroplating process

E-Brite Ultra Cu-Mg. Non-Cyanide, Non-Pyrophosphate Alkaline Copper Plating

PALLADURE 200 Pure Palladium Process

CIRCUPOSIT Electroless Copper (USING CUPOSIT Z AND Y-1) For PWB Metallization Applications

ZINC PLATING SYSTEMS ZCL NH4

SILVER GLO 3K Silver Process

SurTec 650 chromital TCP

is a two component, water soluble, low ammonia zinc plating system suitable for either rack or barrel plating operations. ZCl NH 4

Non-Cyanide, Non-Pyrophosphate Alkaline Copper Plating

ELECTROPOSIT 1100 B-2 Acid Copper Additive

Plating Systems Hex - A - Gone

SurTec 650 chromital TCP

GB/T Translated English of Chinese Standard: GB/T NATIONAL STANDARD OF THE PEOPLE S REPUBLIC OF CHINA

E-Chrome Ultra Yellow 600

Smart Zinc. Zinc Plating System

BONDERITE 1070F CLEANER/COATER PROCESS FOR MULTIMETALS

SOLDERON ST-200 For Electronic Finishing Applications

Use vigorous air agitation while adding the components in the order shown: 2.7% by volume CIRCUPOSIT LC-9100C Electroless Copper

METAL FINISHING. (As per revised VTU syllabus: )

PROBLEM CAUSE SOLUTION

ZINC PLATING SYSTEMS NH4 Zn/Co

I. CUSTOMER INFORMATION: REPORT NO

ENVIRO/Etch Replenisher

SOLDERON BLS For Electronic Finishing Applications

Hex-A-Gone. Hexavalent chromium-free Less energy consumption compared to hexavalent chromium solutions. Plating System

Application Notes for COD Analysis DETERMINATION OF CHEMICAL OXYGEN DEMAND (COD) IN WATER AND WASTE WATER.

HOUGHTO-PHOS 6300 LOW TEMPERATURE MANGANESE PHOSPHATE

Ziniloy Zinc Alloy Plating

PREPOSIT Etch 748. For PWB Metallization Applications. For use in the CIRCUPOSIT 3000 Process. Bath Make-up Metric (for 100 liters)

Technical Data Sheet

Alkaline Non-Cyanide Zinc Plating Process

Transcription:

Postfach 169 CH-9545 Wängi TG 25.07.2014 NITEC CRYSTAL 1 Elektrolyt to achieve uniform and non reflective Nickel deposits In contrast to bright nickel, the NITEC CRYSTAL electroplating process produces non-reflective, satin, fine crystalline nickel deposits. Even on polished surfaces are these deposits non-reflective. Properties Uniform mat deposits across the whole current density range Very active surface condition for subsequent coatings Excellent metal deposit thickness distribution Make up Range Optimum Nickel sulphate (NiSO 4 x 6 H 2 O) 410 460 g/l 435 g/l Nickel chloride (NiCl 2 x 6 H 2 O) 20 40 g/l 30 g/l Boric acid (H 3 BO 3 ) 40 45 g/l 42 g/l NITEC Crystal Carrier W 15 22 ml/l 20 ml/l NITEC Crystal Carrier S 3 10 ml/l 6 ml/l NITEC Crystal Additive 1 0.3 0.8 ml/l dep. on Finish ph-value 4.1 4.5 4.2 Important The satin nickel effect is dependent on daily additions of NITEC Crystal Additive 1. Any other additions are not recommended. Page 1 / 7

Operating values Nickel (Ni 2+ ) 100 110 g/l 105 g/l Chloride (Cl - ) 7 13 g/l 10 g/l Boric acid (H 3 BO 3 ) 40 45 g/l 42 g/l Make up A separate tank is filled with deionised water to 2/3 of the final volume. The water is then heated to at least 60 C after which the chemicals are added and the tank is filled to final volume with deionised water. To remove contaminants 0.5 ml/l Hydrogen peroxide is added and the solution is stirred for at least one hour. This is followed by addition of 3 5 g/l RIASORB activated carbon and mixing for another 30 minutes. After settling, preferably overnight, the electrolyte needs to be transferred to the working tank by filtration. Finally, the correct undiluted volumes of NITEC Crystal Carrier W and NITEC Crystal Carrier S are added. The NITEC Crystal Additive 1 must be diluted 1: 20 with deionised water and mixed well prior to tank addition whilst stirring. All additions should be made ½ 1 hour before starting the electroplating. Important Notice No other organic chemicals (wetting agents etc.) must be added to the electrolyte. The drag-in of other electrolytes could result in bright plating and an increased requirement for NITEC Crystal Additive 1. The pre-plating water rinse should also be deionised water. The ph is corrected by additions of 10 % Sulphuric acid or Nickel carbonate. Operating Parameters Temperature 52 C (50 55 C) The temperature should be maintained above 35 C during idle times ph-value 4.2 (4.1 4.5) Cathodic current density 1.5 5.0 A/dm 2 Anodic current density 1 3 A/dm 2 Tank voltage Rectifier 4 10 Volt < 5 % Ripple Current efficiency < 100 % Deposit rate Anodes Agitation Tanks Agitation at 5 A/dm 2 ca. 1 µm/min Minimum purity 99.7 % Ni. We recommend polypropylene anode bags Cathode Movement 2 3 m/min Plastic or lined steel Cathode movement (3 dimensional) 2-3 m/min with shaking action NITEC Crystal 1 Page 2 / 7

Filtration Heating Cooling Fume extraction Contacting ph-value setup Maintenance It is important not to use filtration during plating! Filtration can be carried out through 5 µm plate or cartridge filters at 4 times bath volume per hour for ca. 8 hours after production. Immersion heaters but thermostatic control is essential not required Recommended Maximal 10 seconds after immersion. Uniform mat coatings are achieved by connecting the work as soon as possible after immersion. To lower the ph chem. pure Sulphuric acid (10 %) is added. To raise the ph only Nickel carbonate must be used. Ammonia or ammonia compounds must not be added. The brightener consumption will increase if the ph is above 4.5 while reduced levelling is noticed at a ph lower than 4.0. Nickel sulphate, nickel chloride and boric acid should be analysed and corrected regularly. Additions of NITEC Crystal Carrier W and NITEC Crystal Carrier S are made via ampere-hour consumption. Metallic contamination can be removed by frequent selective plating-out at 0.1 0.3 A/dm 2. The filter pump should be on with the filter outlet directed at the panels. This will ensure thorough electrolyte circulation and essential agitation at the same time. Minimal thickness Additive consumption The mat effect requires a minimum layer thickness of 3 5 µm. The additives are consumed during electrolytic reactions as well a dragout losses and the use per 10 kah can therefore vary. NITEC Crystal Carrier W NITEC Crystal Carrier S 0.5 1.5 L/10 kah 0.5 0.8 L/10 kah Too low concentrations of the Nitec Crystal Carriers reduce the crystal mat effect. The nickel concentration should be maintained within close operating parameters to achieve optimum crystal mat deposits. The NITEC Crystal Additive 1 can also be replenished during plating. This will ensure uniform quality deposits and 1: 20 diluted additions of up to 50 % of the original concentration can be made at 4 hours interval. The mentioned values are guidelines and may vary slightly in praxis. Equipment The NITEC Crystal Additive 1 process can be operated on a production basis without problems but relevant plant changes must first be considered.our technical team is ready to advise you accordingly. A trouble-shooting guide is available on request. NITEC Crystal 1 Page 3 / 7

Function of the Additives NITEC Crystal Additive 1 The function of this additive is to ensure non-reflective deposits. Increasing the concentration will intensify this mat effect. Overdosing (> 1 ml/l) results in porosity at high current densities. Prior to adding the NITEC Crystal Additive 1 has to be diluted 1: 20 with deionised water. The mixture is then added carefully whilst stirring. The operational window lies between 8 14 hours depending on plant technology. Thereafter the electrolyte must be filtered to remove the NITEC Crystal Additive 1 residue and we recommend activated carbon filtration for duration of approximately 6 8 hours. NITEC Crystal Carrier S The NITEC Crystal Carrier S concentration can be determined by analysis and we recommend maintaining operational limits at all times. A too low concentration causes porosity during plating while overdosing results in poor crystal mat formation. Regular additions according to the data sheet must be made. NITEC Crystal Carrier W The NITEC Crystal Carrier W concentration can also be determined analytically and we recommend maintaining the minimum level at all times. While too low concentrations cause bright plating, slight overdosing is not detrimental. Regular additions must be made according to the data sheet. The NITEC Crystal W- and S can be mixed for use in automatic dosing systems. Important The filter pump must be switched off prior to NITEC Crystal Additive 1 additions and during plating otherwise the NITEC Crystal Additive 1 is removed from the electrolyte. Nickel additive NITEC Z Zinc-die casting processing in rack mode often leads to zinc and copper electrolyte contamination. This can be treated by additions of 0.1 0.5 ml/l NITEC Z. The volume NITEC Z to be added depends on contamination levels. Stabiliser F Iron contamination (pitting) can be removed effectively by additions of Stabiliser F. The maximum concentration of 0.5 g/l should not be exceeded. The salt is first dissolved in hot water and the iron is removed via the filter. Nickel Concentration The nickel concentration has only a limited effect on deposit appearance as long as the operational concentration is maintained above 100 g/l nickel. Lower values tend to reduce the mat-effect and must be adjusted by nickel sulphate additions accordingly. NITEC Crystal 1 Page 4 / 7

Chloride Concentration Too high concentration results in a slight brightening effect while lower values do not affect deposit quality. Boric acid The Boric acid concentration has, within operational limits, little influence on deposit quality. However, too low values tend to cause deposit burning or pitting. Activated Carbon The NITEC Crystal Additive 1 is removed by filtration and activated carbon treatment is beneficial during this stage for the removal of organic breakdown products as well. For this we recommend our dust-free product RIASORB SF that has an active surface area of 1500 m 2 /g. Environmental considerations and product safety All concentrates, rinse waters and waste solution must be treated and discharged in accordance with local effluent control regulations. Information can be gleaned from the material safety data sheets. Chemicals shall not be stored below 10 C. Liability This instruction manual was compiled with reference to the state of the art and all current standards, and is based on the long-term knowledge and experience of RIAG. However, RIAG cannot monitor compliance with this instruction manual and the methods described herein at the customer/end-user's premises. Work carried out with RIAG products must be adapted accordingly to meet local conditions. In particular, RIAG cannot accept liability for damage, loss or cost incurred due to a failure to adhere to this instruction manual, improper application of the methods, unauthorised technical modifications, insufficient maintenance or the absence of maintenance in respect of the requisite technical hardware or equipment, or in the event of use by unqualified personnel. RIAG is not liable for damage or loss caused by RIAG or its employees except where intention or gross negligence can be proved. RIAG furthermore reserves the right to make changes in relation to products, methods and the instruction manual without prior notice. Our goods and services are subject to the General Terms and Conditions for Delivery of the Association of Surface Technology Suppliers (VLO), which can be viewed at www.ahc-surface.com (link "General Terms and Conditions", document " (Wängi, Switzerland) 50 KB", version 1/2014), which we would be glad to send to you on request. This transaction is governed by material Swiss law (Law of Obligations), excluding private international law (conflict of laws) and intergovernmental treaties, specifically the CISG. Murgstrasse 19a CH- 9545 Wängi Tel. + 41 (0) 52 / 369 70 70 Fax + 41 (0) 52 / 369 70 79 www.ahc-surface.com info.waengi@ahc-surface.com NITEC Crystal 1 Page 5 / 7

Analysis (Analytical Methods) Sample preparation: The sample must be taken from a well-mixed point and allowed to cool down to 25 C. Boric acid Reagents: Sodium hydroxide solution 0.1 mol/l Bromcresol purple (1 % in Ethanol) Mannitol Procedure: 10 ml bath are transferred via pipette into a 100 ml measuring flask and filled up to the mark with deionised water followed by mixing well. 10 ml of this mixture is given into a 250 ml beaker via pipette followed by 100 ml deionised water addition. 2 3 g Mannitol is added followed by addition of 10 drops Bromcresol purple. Titration with 0.1 mol/l Sodium hydroxide from yellow to green, to dark green and finally to blue-violet. Calculation: Boric acid (g/l) = consumption of ml NaOH x 6.18 Nickel chloride Reagents: Silver nitrate solution 0.1 mol/l Potassium dichromate solution 5 % Procedure: 5 ml bath are transferred into a 250 ml glass beaker and diluted with 50 ml deionised water. 10 drops of Potassium dichromate solution are added. Titration with 0.1 mol/l Silver nitrate solution from white yellow to a light brown end point. Calculation: Nickel chloride (g/l) = consumption of ml AgNO 3 x 2.380 Chloride (g/l) = consumption of ml AgNO 3 x 0.709 NITEC Crystal 1 Page 6 / 7

Nickel Reagents: Buffer solution ph 10 Komplexon III solution 0.1 mol/l Murexide (Sodium chloride 1: 100) Procedure: 10 ml bath are transferred via pipette into a 100 ml measuring flask and filled- up to the mark with deionised water and mixed well 10 ml of this mixture is given into a 250 ml glass beaker by pipette followed by 15 ml Buffer solution addition 100 ml deionised water and 1 spatula tip of Murexide are added The sample colour should then be deep yellow Titrate immediately with the Komplexon III 0.1 mol/l solution to a blue- end- point. Calculation: Nickel (g/l) = consumption of ml Komplexon III x 5.869 Nickel sulphate (g/l) = [A (B x 0.247)] x 4.48 A = Nickel concentration in g/l B = Nickel chloride conc. in g/l NITEC Crystal 1 Page 7 / 7