Installation manual ValkTriple EN-UK

Similar documents
Installation manual ValkTriple UK

User manual ValkDouble

Installation manual ValkFlat East West - Portait

Installation manual ValkPro+

ValkDouble. Installation manual. Van der Valk Solar Systems. Solar Mounting Systems. Version 07 EN

ValkQuattro. Installation manual. Van der Valk Solar Systems. Solar Mounting Systems. Version 07 EN

Installation manual ValkPro+ East West

Installation manual ValkPro+ East West

Installation manual ValkField - Single Row

Installation manual Flat Roof Insert System

Installation manual Pitched Roof Insert System

Installation manual Field System - Double Row

ValkPitched - Clamp. Installation manual. Van der Valk Solar Systems. Solar Mounting Systems. Version 17 EN

ValkPitched - Standing Seam

ValkPitched - Bitumen

ValkFlat East West - Portrait

ValkPro- Massblock. Installation manual. Van der Valk Solar Systems. Use in combination with the installation manual of the ValkPVplanner

ValkFlat East West - Landscape

ValkPro+ East West. Installation manual. Van der Valk Solar Systems. Use in combination with the Project Report of the ValkPVplanner

ValkPro+ East West. Installation manual. Van der Valk Solar Systems. Use in combination with the Project Report of the ValkPVplanner

ValkPro+ East West. Installation manual. Van der Valk Solar Systems. Use in combination with the Project Report of the ValkPVplanner

ValkPro+ Installation manual. Van der Valk Solar Systems. Use in combination with the Project Report of the ValkPVplanner. Solar Mounting Systems

ValkPitched - Insert

ValkPitched - Clamp. Installation manual. Van der Valk Solar Systems. Use in combination with the Project Report of the ValkPVplanner

Mounting systems for solar technology

Conergy SolarFamulus II

INSTALLATION GUIDE Sika SolarMount 1 Exposition East West

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

PATENT PENDING FLAT ROOF PV SYSTEM. FDGlight

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

MOUNTING SYSTEMS APPLICATIONS OVERVIEW

Mounting systems for solar technology

On-roof system Tau Installation manual

ConSole, ConSole+ Flat-roof mounting system for PV-modules and -laminates. From visions to solutions

BISOL EasyMount Structures

Rack-in-a-BoxTM INSTALLATION MANUAL

EASY ROOF FLAT PV FIXING SYSTEM FOR FLAT ROOF

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

mounting systems applications overview

Mounting systems for solar technology

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

Mounting instructions. novotegra for trapezoidal metal - roof parallel

Mounting systems for solar technology

Installation instructions

Mounting instructions

installation instructions English

Installation instructions

MANUAL FLATFIX FUSION MOUNTING SYSTEM FOR FLAT ROOFS

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

Mounting systems for solar technology

Solar products. Schüco mounting system MSE 210 flat roof

MOUNTING SYSTEMS PRODUCT CATALOG

PRODUCT OVERVIEW PV FLAT ROOF MOUNTING SYSTEMS

Installation Guide EcoFoot5D High Density 5-Degree Ballasted Racking System Document No. ES10560

ConSole. Installation instructions

MANUAL FLATFIX FUSION MOUNTING SYSTEM FOR FLAT ROOFS

Substructures for PV power plants

Mounting Systems South. Information

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

Protective Capony RTC-16

MANUAL FLATFIX FUSION MOUNTING SYSTEM FOR FLAT ROOFS

Statics. Stability. Safety. Photovoltaic mounting system

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. D-Dome System.

Mounting System MCG 1.1 Membrane-Connected Glass. System description

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

Professional Photovoltaic Solutions.

INSTALLATION INSTRUCTIONS AS 2.1 CORRUGATED ETERNIT ROOF

User instructions for photovoltaic modules 60Pxxx-V 60Mxxx-V 72Pxxx-V 72Mxxx-V 60Pxxx 60Mxxx 72Pxxx 72Mxxx

STP Mount Series. Installation Manual. STP-LSCR-MAN 2017 Edition v1.0. For models: STP-SCR/045 STP-SCR/060 STP-SCR/070 STP-LCR/090 STP-LCR/120

Mounting instructions. novotegra for folded seam roof

INSTALLATION INSTRUCTIONS TRI-STAND East-West. energy for a better world. Mounting system for PV systems with east-west orientation on flat roofs

ifix INSTALLATION MANUAL PV flat roof installation system Version

HELIOSTAR 252, 218 HORIZONTAL, FREE INSTALLATION

Radiant PV-RoofTopRac System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

AluGrid product sheet

Sub-construction for Wall-mounted Longlight

YINGLI SOLAR TWINMAX MODULES Installation and User Manual

00MK-MA0160-EN00. Mounting System ASSEMBLY INSTRUCTIONS. Little Plan and Little Plan Light systems, for corrugated sheet metal roof

installation instructions English

Model m x 1.98 m NPRM with Roof Pads For 1.2 m Antenna Systems

INSTALLATION INSTRUCTIONS ENGLISH

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. SpeedRail System.

MANUAL. portrait set-up. landscape set-up. ClickFit Evo mounting system for sloping roofs with roof tiles for solar panels

Radiant PV-Solar Tripod System Planning and Installation With Australia AS/NZS1170.2:2011 AMDT

Wind uplift testing on the Click Fit PV mounting system to MCS012. Prepared for: Gary Bowden Cleaner Air Solutions UK Ltd.

Installers Guide. Item

Highways Square Trolley Pole. HSTP Range. Sales Direct: +44 (0) w: e: Highways Square Trolley Pole

Ground Mounting System I Installation Manual

RAPID Column Formwork For the highest requirements on concrete surfaces and edge formation. Product Brochure Issue 10/2017

GroundTrac. Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

Infix ProLine Installation manual

Original Scandinavian rainwater system

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

Installer Guide. Item

Solar Panel Mounting Kits

Installation Guide EcoFoot2+ 10-Degree Ballasted Racking System Document No. ECO-002_850. Rev 1.6, January 2018

Mounting System MCG 3.0 Membrane-Connected Glass. System description

PV-ezRack SolarMatrix Pro

Transcription:

Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Installation manual ValkTriple EN-UK Version 08

EN General user instructions Solar mounting systems Congratulations on buying a Van der Valk Solar Systems mounting system and on helping the environment by deciding to install solar panels. This document must be seen in addition to the installation manual and installation instructions. * The general user instructions describe general installation and safety instructions. * The installation manual shows you how to install the solar mounting system. * The installation instruction gives you specific measures of the engineered mounting system as a result of the 1-2-3 PV Planner. The instructions provided in these user instructions must be observed at all times. Read these instructions carefully and keep them in a safe place for future reference. lso follow the instructions stated in the manuals and instructions for the other system components that are a part of the overall PV system. ll current structural, safety and building regulations must be observed. Van der Valk Solar Systems B.V. will never be liable for any direct and/or indirect intangible or consequential loss ensuing from or connected to the failure to observe the instructions provided in these user instructions. Safety instructions for roofs Solar mounting systems installed on roofs will be exposed to wind and snow. The building in question will be subject to a greater load as a result of the PV system. design calculation must be used to establish whether or not the building in question will be able to withstand the extra load. Where necessary, modifications need to be made. The standards applied (if applicable for specific solar mounting system) EN 1990 Basis of structural design EN 1991-1-3 ctions on structures / Snow loads EN 1991-1-4 ctions on structures / Wind actions EN 1993-1-1 Design of steel structures / General rules for buildings EN 1993-1-3 Design of steel structures / Supplementary rules for cold formed members EN 1997 Geotechnical design EN 1998-1 Design of structures / General rules, seismic actions and rules for buildings EN 1999-1-1 Design of aluminium structures NEN 7250 Solar systems - Integration in roofs and facades - Building aspects (pending) BS EN 1991-1-4 British Standard pplication To calculate the needed strength, ballast and foundation of the solar mounting system, according the Eurocodes, the specific location details have to be determined, e.g. wind zone, snow zone and height of the building. These need to be entered in the 1-2-3 PV Planner. Foundations and strength of field systems are calculated with SolarTop. Type of solar panel The Van der Valk Solar Systems mounting systems are universal mounting systems for solar panels. lmost any solar panel with of without an aluminium frame, possibly with mounting holes, can be mounted. Types of roof Type of roof covering: bitumen, EPDM, PVC, concrete and other roof coverings. For ballast calculations the exact roof covering must be known. Before installing the solar mounting system, make sure that you carefully sweep the roof area. The ballast calculation for flat roofs only applies for roofs with a slight pitch of up to 5. bove this roof pitch, the system needs to be attached to the roof securely. Ballast Flat roof systems can be attached to the roof or need to be supported by ballast, to make sure that the system is unable to move, lift or tip over. The components supplied do not fully include the ballast required, which will be a number of tiles with a certain measurement and weight. The number of tiles required per position, per type of solar panel, per roof area and per building height is calculated via the 1-2-3 PV Planner and can be seen in the installation instructions and foundation adivse. The number of tiles specified per position will be vital to ensure that the mounting system can be used safely. Position Restrictions also apply for the position of the system on a roof. The solar panels must be installed at a certain distance from the edge of the roof. Follow the scheme in the installation manual calculated by the 1-2-3 PV Planner. Guarantee The guarantee provided is subject to the guarantee conditions stated in the general terms and conditions stipulated by Van der Valk Solar Systems BV. Our terms and conditions can be found on our website: www.valksolarsystems.nl. The mounting system is a product that has been produced by: Van der Valk Solar Systems B.V., Registered with the chamber of commerce for Haaglanden under number 27355116. Internet: www.valksolarsystems.nl Issue date : May 2014 Version: General user instructions v2 EN

EN GB User manual ValkTriple Universal installation system for flat roofs Congratulations on buying the ValkTriple mounting system and on helping the environment by deciding to install solar panels. The ValkTriple mounting system is an universal mounting system that can be used to install 3 standard solar panels in a landscape set-up one above the other, with a tilt angle of 10, on a flat roof with a height up to 10 m. The components supplied do not include the additional ballast required, which will be a number of tiles. The weight of tiles required per position, per type of solar panel, per roof area and per building height is specified in the tables on page 8 of this document. Safety instructions The ValkTriple mounting system shall be installed on roofs and will be exposed to wind and snow. The building in question will be subject to a greater load as a result of the solar system. design calculation must be used to establish whether or not the building in question will be able to withstand the extra load. Where necessary, modifications need to be made. When installing the ValkTriple mounting system, the instructions provided in this user manual must be observed at all times. Read this manual carefully and keep it in a safe place. lso follow the instructions stated in the manuals for the other system components that form part of the overall solar system. ll current structural, safety and building regulations must be observed. Van der Valk Solar Systems B.V. will never be liable for any direct and/or indirect intangible or consequential loss ensuing from or connected to the failure to observe the instructions provided in this manual. Starting points The following starting points apply for the ValkTriple mounting system: The standards applied NEN-EN 1990 : Eurocode Basis of structural design NEN-EN 1991-1-4 : Eurocode 1: ctions on structures - Part 1-4: General actions Wind actions NVN7250 : Solar energy systems Integration in roofs and facades Constructional aspects BS EN 1991-1-4 : British Standard

Type of solar panel The ValkTriple mounting system is an universal mounting system for solar panels. The following starting points apply: Panel design : Standard solar panels with an aluminium frame. Panel length : pprox. 165 cm Panel width : 98-101 cm Thickness of the aluminium frame : 28-50 mm Panel weight : pprox. 20 kg Types of roof The ValkTriple mounting system can be used to mount panels on flat roofs. The following starting points apply: Type of roof covering: bitumen, EPDM and concrete (for the ballast applicable per type of roof covering, see the tables on page 8 of this document). Before installing the ValkTriple mounting system, make sure that you carefully sweep the roof area. The ballast calculation for the ValkTriple mounting system (see page 8 of the manual) only applies for flat roofs and roofs with a slight pitch of up to 5. bove this roof pitch, the system should be attached to the roof securely. Ballast The ValkTriple mounting system needs to be supported by ballast, to make sure that the system is unable to move, lift or tip over. See page 8 of this document for details of how many ballast should be used for each type of solar panel, each region, each type of roof covering and for each building height (subject to a maximum of 10 m). The weight specified per position will be vital to ensure that the mounting system can be used safely. To achieve this, follow the instructions on the ballast required on page 8 of this document. Position Restrictions also apply for the position of the system on a roof. The solar panels must be installed at a certain distance from the edge of the roof. ccording to the current standard, NEN-EN 1991-1-4, this free edge zone is 1 / 5 of the height of the roof. So, if a roof is 6 metres high, a free edge zone of 120 cm will be necessary. Guarantee The guarantee provided is subject to the guarantee conditions stated in the general terms and conditions stipulated by Van der Valk Solar Systems B.V. Our terms and conditions can be found on our website: www.valksolarsystems.nl. The ValkTriple mounting system is a product that has been produced by: Van der Valk Solar Systems B.V., Registered with the chamber of commerce for Haaglanden under number 27355116. Internet: www.valksolarsystems.nl Issue date: July 2014 Version: VLK-USER-EN/GB-ValkTriple Flat Roof-2014-05

Ballast requirements General The ValkTriple mounting system must be weighted down by tiles, which will be placed at positions G2 and G3. Start by choosing the wind area in which the system will be installed from the overview on page 8. Next, look at the table for the panel length in question. In this table, you will choose the relevant type of roof covering. Bitumen and EPDM have a higher frictional resistance and it will be possible to use less ballast for this type of roof covering. Next, choose the table for the wind area in question and the row for the building height applicable. This will show you the weight necessary for positions G2 and G3.

Selection table: Minimum number of kilograms per position G2 and G3. Based on: * Category: Town (sites more than 1km inside town boundary - area where at least 15% of the surface is covered with buildings with an average height above 15m) * Distance to shoreline: >10km * Maximum height above sea level: <100m

Van der Valk Solar Systems TRCKING ND FIXED SOLR MOUNTING SYSTEMS Please Note This manual is not project specific. This manual is not legally binding. No rights may be derived from this manual. Check Datasheet Cable management for cable suggestions. The system is placed in the middle zone of the roof. Table of contents General user instructions Page - Necessary tools Page - Measurements Page 01 Coupling of the roof carriers Page 02 Front mass block Page 03 Rear mass block Page 04 -frame connector Page 05 Push-rods Page 06 Subassembly profile Page 07 Mounting subassembly Page 08 Push-rods Page 09 Ballast Page 10 End clamp Page 11 Panel clamp Page 12 DC cable clamp Page 13

Necessary tools for ValkTriple Wrench 13 Socket 13 Torx bit T-30 Cordless drill (for socket 13 and bit T-30)

10 677 Measurements (mm) ValkTriple 3109 Panel thickness 28-50 825 1700 600 2700 Panel length dvised pitch measure 5000 (Based on sun angle of 14,5 ) 3128 01

Coupling of the roof carriers 74.18.01000 74.18.01600 Detail 77.42.21 B Detail B The groove of the bolt correponds with the orientation of the bolt head. 1600 1000 825 02

Front mass blocks 75.05.20 Detail 72.96.10 M8x65 77.40.65 M8 77.40.08 825 3rd hole of roof carrier 03

Rear mass blocks 75.05.20 Detail 72.96.10 M8x220 74.79.74 M8 M8 77.40.06 77.40.08 1st hole from end of roof carrier 825 7th hole from end of roof carrier 04

-frame connector 72.44.20 Mount hole to the front Detail 4th hole from end of roof carrier The groove of the bolt correponds with the orientation of the bolt head. 2200 825 2nd hole of roof carrier 05

G13.03.22.0825.00.00 Push-rods Detail M8x20 77.42.20 M8 77.40.06 3rd hole from end of roof carrier The groove of the bolt correponds with the orientation of the bolt head. 2100 825 4th hole of roof carrier 06

Subassembly profile 72.7.1010 72.7.2100 Detail B Detail C 00.48.50 72.44.50 Detail 72.44.14 C M8x20 77.40.20 B M8 77.40.06 07

Mounting subassembly profile Subassembly profile Detail M8x70 77.40.71 M8 77.40.06 08

G13.05.77.0380.0000 Push-rods G13.03.22.0865.65.65 Detail M8x70 77.40.71 M8 77.40.06 Detail B B B 09

Ballast 72.51.40 Detail M8 77.40.06 Not included Tile Tile 300x300x45 mm Refer to the ballast table in front of this manual. 2 extra tiles 4 extra tiles 6 extra tiles 8 extra tiles Turn tile clamp upside down. 10

End clamp 72.15.52 1 Detail Detail 2 3 Take the End Clamp out of it's slot to make the assembly easier. The End Clamp can only be turned clockwise, so make sure that the End Clamp is placed the right way. 4 Detail 8Nm 5 Put the End Clamp in the right slot to continue the assembly. 11

Panel clamp 72.15.50 Detail 4 1 (To mount end clamp see page 11.) 5 3 8Nm 2 4 12

73.20.01 Max. cable diameter Ø 9 mm DC cable clamp Mount cable clamp on the panel. 13

Van der Valk Solar Systems Van der Valk Solar Systems is a specialist company that is fully focused on developing and producing mounting systems for use with solar panels. To this end we work in close collaboration with Van der Valk Systemen, our sister company. Van der Valk Systemen has been a well-known name in the field of moving systems and stationary components for the greenhouse horticultural sector and industry throughout the world since 1963. Van der Valk Systemen s high quality products have been individually developed from a scientific approach and produced with mathematical precision. They are made to be low-maintenance and to stand out thanks to their durability, reliability, functionality and ease of assembly. Both Van der Valk Systemen and Van der Valk Solar Systems only introduce innovative products to the market. Our shared business complex consists of 20,000 m 2 of offices and production facilities, in which modern machinery and the latest technologies facilitate development, manufacturing and testing that is fast, flexible and precise. Developer and producer of solar mounting systems for: Open Fields Pitched Roofs Flat Roofs Greenhouses Water Features