TaqPath ProAmp Master Mixes

Similar documents
TaqPath ProAmp Master Mixes

TaqMan SNP Genotyping Assays

Applied Biosystems Real-Time PCR Rapid Assay Development Guidelines

Validate with confidence Move forward with reliable master mixes

QuantiNova proven compatibility with various real-time cyclers in gene expression analysis

Touchscreen (standalone capabilities, PIN-protected user accounts, and dye calibration/rnasep functionality)

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

APPLICATION NOTE. The QuantStudio 12K Flex Real-Time PCR System

myt KRAS qpcr primers for detection of seven human KRAS codon 12/13 mutations:

MOLECULAR SOLUTIONS FOR BIOTECHNOLOGY


PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

Simple, Complete Workflows for Gene Expression Analysis without RNA Purification

3 r. ProbeSure Genotyping Master Mix User Guide. Cbioscience. Page 1 ProbeSure User Guide v1.4

Applied Biosystems 7500 Fast Real-Time PCR System

AmpFlSTR Identifiler PCR Amplification Kit

GreenMasterMix (2X) b i o s c i e n c e. G E N A X X O N b i o s c i e n c e. High ROX (500nM)

3C bioscience. ProbeSure Genotyping Master Mix User Guide. P a g e 1 ProbeSure User Guide v1.0

ProNex DNA QC Assay Calibration Kit, 7500

QuantStudio 3 and QuantStudio 5 Real-Time PCR Systems. Connect to your data anytime, anywhere

Escherichia coli_o104: H4

QuantStudio 3D Digital PCR System

M. tuberculosis_mpb64/is611. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

MAXimum results. Minimum effort.

Table of Contents. I. Kit Components...2. Storage...2. Principle...2. IV. Precautions for operation...3. V. Protocol : reverse transcription...

Maize CaMV promoter & NOS terminator (GMO)

USB HotStart-IT. for increased specificity and consistent results. PCR, qpcr and qrt-pcr

Cat. # RR391A. For Research Use. Probe qpcr Mix. Product Manual. v201610da

TaqMan Sample-to-SNP Kit

Love Bird (Agapornis) Sexing Sex chromosome specific spindlin gene. Advanced Kit. 150 tests. For general laboratory and research use only

Detection of FactorV Leiden (R506Q)

MAXimum results. Minimum effort.

HID Real-Time PCR Analysis Software v1.3

Precise quantification of Ion Torrent libraries on the QuantStudio 3D Digital PCR System

NOS terminator (GMO) genesig Advanced Kit. NOS terminator. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Thermo Scientific Direct PCR

TaqMan Advanced mirna Assays

Tamiflu resistance detection kit

User Manual. NGS Library qpcr Quantification Kit (Illumina compatible)

PrimeScript RT Master Mix (Perfect Real Time)

PERFORMANCE MADE EASY REAL-TIME PCR

Simply greater performance for all your qpcr needs. qpcr Master Mixes

Applied Biosystems 7500 Fast, 7500 and 7300 Real-Time PCR Systems

Internal DNA extraction control

FMV 35S promoter (GMO) Advanced Kit. FMV 35S promoter. 150 tests. For general laboratory and research use only

Epstein Barr Virus (Human Herpes virus 4)

Introducing a new generation of affordable choices from the leader in real-time PCR. Applied Biosystems 7500 Fast Real-Time PCR System

RealHelix TM qrt-pcr Kit [Intercalator type]

winter savings one place High Quality Costs Less Look inside to find great deals on Thermo Scientific products for all your molecular biology needs

TaqPath 1-Step Multiplex Master Mix

SYBR Green Realtime PCR Master Mix

Pistacia vera. Introduction to Pistacia vera. 100 tests. Techne qpcr test. For general laboratory and research use only

Merkel Cell Polyomavirus

Acinetobacter baumannii

hpsc Genetic Analysis Kit

Techne qpcr test. A graveolens. NADPH-dependent mannose 6- phosphate reductase (m6pr) 100 tests

Techne qpcr test. Pisum sativum. Ribosomal protein S12 (rps12) gene. 100 tests

Mycobacterium genus (all species)

Fully Automated Library Quantification for Illumina Sequencing on the NGS STAR

Primerdesign Ltd. High risk Human Papillomavirus. Multiplex screening kit. genesig kit. 100 tests. For general laboratory and research use only

Genomic DNA quantification assay. Quantification of genomic DNA by real-time PCR

Internal RNA extraction control. Instructions for use of RNA real-time PCR internal extraction control kit

Premix Ex Taq (Probe qpcr)

Detection of CFTR(F508) MyBioSource.com. Real-time PCR mutation detection/allelic discrimination kit. For general laboratory and research use only

Antibiotic resistance OXA -48 Carbapenem-hydrolyzing β- lactamase (blaoxa-48) gene. genesig Advanced Kit. 150 tests.

Lactobacillus 16S Ribosomal RNA. genesig Advanced Kit. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Functional Genomics Research Stream. Research Meeting: June 19, 2012 SYBR Green qpcr, Research Update

Real-Time PCR Validations

Human Papillomavirus 16

Human Herpes Virus 1 (Herpes simplex type 1)

Accurately and reproducibly quantify as little as 20 fg of bacterial DNA using real-time PCR.

Mycobacterium Tuberculosis

White Paper: High Throughput SNP Genotyping Using Array Tape in Place of Microplates

Detection of Prothrombin (G20210A)

BRCA MAQ USER GUIDE Version 1.0


Arachis hypogaea A.hypogaea. genesig Allergen detection Kit. 100 tests. Primerdesign Ltd. For general laboratory and research use only

TaqMan Advanced mirna Assays

Mycobacterium Tuberculosis


Aureobasidium pullulans

Lactobacillus. 16S Ribosomal RNA. 150 tests. Quantification of Lactobacillus genomes. Advanced kit handbook HB

Protocol for Creating Custom RT and Preamplification Pools using TaqMan MicroRNA Assays

A Recommended Procedure for Real-Time Quantitative TaqMan PCR for Roundup Ready Canola RT73 Monsanto Biotechnology Regulatory Sciences

SYBR Green Realtime PCR Master Mix -Plus-

Frequently Asked Questions

Acinetobacter baumannii

myt BRAF - Ultra qpcr Primers for Ultra-sensitive Detection of Human BRAF V600E/K For Research Use Only

Adenovirus Type C. Hexon gene. 150 tests. Quantification of Adenovirus Type C genomes. Advanced kit handbook HB Published Date: 28/11/2017

3color RT HS-PCR Mix SYBR Ready-to-use mix for real-time Hot Start PCR with SYBR Green. Dedicated for white reaction tubes and plates.

Choose Your Own PCR/qPCR Path

An Introduction to Digital PCR. The world leader in serving science

Accurately and reproducibly quantify as little as 20 fg of human DNA using real-time PCR.

Multiplex SNP Genotyping of Field Corn Crude Samples with Probe-Based Assays using the IntelliQube from Douglas Scientific INTRODUCTION

Equus caballus Horse Speciation Kit

Staphylococcus epidermidis

Internal RNA extraction control. Instructions for use of RNA real-time PCR internal extraction control kit

Mycoplasma felis. Elongation factor Tu (tuf) gene. 150 tests

Epstein Barr Virus (Human Herpes virus 4)

High specificity and sensitivity for fungal DNA allows reliable quantification in a background of nonfungal. Contents

Transcription:

PRODUCT BULLETIN es es Applied Biosystems TaqPath ProAmp Master Mixes are versatile master mixes developed for high-throughput genotyping and copy number variation (CNV) analysis protocols that require accurate results from samples containing PCR inhibitors. TaqPath ProAmp Master Mixes are designed to deliver sensitive and reproducible results from genomic DNA targets. The simple genotyping and CNV analysis workflow (Figure ) and reproducible performance even in the presence of inhibitors offer confidence in results. We offer two formulations for different throughput needs:, which includes ROX passive reference dye TaqPath ProAmp Multiplex Master Mix, which includes Mustang Purple passive reference dye for multiplexing up to 4 targets Both mixes enable measurement of FAM, VIC, ABY, and other dyes with similar emission wavelengths. The multiplex version also allows the use of JUN dye, or other dyes with similar emission wavelengths, in the channel typically used to measure ROX dye for single nucleotide polymorphism (SNP) genotyping and other highermultiplex applications. These two formulations expand our line of Applied Biosystems TaqPath general purpose reagents to include master mixes for genotyping and CNV analysis in addition to qpcr and RT-qPCR master mixes, all of which are manufactured in an ISO 3485 certified facility with stringent production and process controls to help ensure excellent manufacturing consistency. With over 5 years of technology leadership in real-time PCR, we are committed to continually providing laboratories with trusted, versatile, and innovative tools for the future of molecular diagnostics. Combine assays and master mix Add mix to plate containing purified genomic DNA or crude lysate (genotyping) 3 Run on Applied Biosystems real-time PCR instrument 4 Analyze using genotyping or CopyCaller software Figure. Workflow for.

Features of Exceptional data quality high specificity, dynamic range,* and reproducibility for genotyping and copy number determination, even in the presence of inhibitors Tolerance to inhibitors compatible with samples prepared from human or animal sources (buccal swabs, blood, and card punches) 7-hour pre-pcr benchtop stability flexible plate setup for automated workflows, enabled by our Dual-Lock Taq DNA polymerase s hot-start mechanism Multiplexing breadth two formulations that enable detection of up to four targets per reaction Excellent manufacturing consistency manufactured in an ISO 3485 certified facility to help ensure excellent manufacturing consistency High-accuracy genotyping Accuracy in genotyping is important where limited amounts of samples are available, for example in clinical diagnostic testing. has been optimized to yield accurate and reproducible results, even in lowvolume reactions, with ng input per reaction. Figure shows a comparison of genotyping accuracy between and other commercial master mixes for the same set of Applied Biosystems TaqMan Drug Metabolism SNP Genotyping Assays** using crude lysate from blood samples. has been optimized to provide high specificity for allelic discrimination, as demonstrated by excellent cluster separation in genotyping plots, whether the sample is purified genomic DNA or crude lysate. TaqPath ProAmp Master Mix Supplier B Supplier K SNP SNP SNP 3 Figure. Genotyping results from vs. other commercial master mixes. Crude lysates were prepared from blood samples and diluted 0-fold. Results are shown for three TaqMan Drug Metabolism SNP Genotyping Assays run under standard conditions. TaqPath ProAmp Master Mix consistently produced accurate genotype calls and excellent cluster resolution across multiple assays. Dark blue, green, and red colors correspond to data with genotype calls assigned by the Thermo Fisher Cloud Genotyping application. Light blue corresponds to no template (no DNA) controls, yellow corresponds to samples with signal too low to assign genotype calls, and black corresponds to samples of undetermined genotype.

High-accuracy copy number quantitation The versatile TaqPath ProAmp Master Mix can also be used for highly accurate CNV analysis using purified genomic DNA samples. Figure 3 shows a comparison of CNV results using and two other commercial master mixes. TaqPath ProAmp Master Mix can accurately determine copy number in samples with up to 4 copies (data not shown). High reproducibility Clinical diagnostic testing requires high reproducibility in genotyping and copy number results. TaqPath ProAmp Master Mix has been optimized to achieve low standard deviation in C t values, enabling highly reproducible results with both fast and standard ramp rates, even with samples containing PCR inhibitors. Figure 4 shows a comparison of C t standard deviations derived from the use of and three other commercial master mixes with an RNase P gene assay that typically serves as a reference in CNV quantitation. The results demonstrated high reproducibility from. A B Copy number Copy number 0 4 3 0 -copy samples Sample 3-copy samples Sample -copy samples Sample Sample 3 Sample 4 Sample 5 Sample 6 Sample 7 Sample 8 Sample 9 Sample 0 Sample Sample Sample 3 Sample 4 Sample 5 Supplier K -copy samples -copy samples Sample Sample 3 Sample 4 Sample 5 Sample 6 Sample 7 Sample 8 Sample 9 Sample 0 Sample Sample Sample 3 Sample 4 Sample 5 Figure 3. CNV analysis using vs. other commercial master mixes. yields copy number results closer to expected integer values. (A) Copy number quantitation results for CYPD6 intron, based on assays run using TaqPath ProAmp Master Mix (green) and mix (blue). Genomic DNA purified from buccal swabs using the Applied Biosystems MagMAX DNA Multi-Sample Kit was used at an input of 0 ng per well, 4 replicates per sample. (B) Copy number quantitation results for CYPD6 intron 6, based on assays run using (green) and Supplier K mix (blue). Genomic DNA from blood was purified and used as described in (A). Annotations in orange ( -copy samples, 3-copy samples ) highlight samples that demonstrate the superior accuracy and reliability of TaqPath ProAmp Master Mix, in comparison to the alternative supplier s product..5 Supplier K genotyping mix gene expression mix TaqPath ProAmp Master Mix.0 C t standard deviation.5.0 0.5 0.0 0.0 0.0 0.3 0.0 0.0 0.0 0.3 0.0 0.0 0.0 Final sample to reaction volume ratio 0.3 0.0 0.0 0.0 0.3 0.0 Figure 4. Mean C t standard deviations for vs. other commercial master mixes. Results are based on 8 replicate qpcr reactions using an RNase P gene assay and increasing ratios of blood sample volume to reaction volume. has a low standard deviation for C t values, relative to the other commercial master mixes, at the recommended 0.0 input ratio and across all ratios up to 0% of reaction volume.

Multiplexing Both and TaqPath ProAmp Multiplex Master Mix can be used for multiplex reactions, allowing additional exogenous or endogenous controls or targets to be assayed simultaneously for quality control or increased efficiency. Both versions of the mix can be used in conjunction with Applied Biosystems TaqMan probes** with FAM, VIC, and ABY reporter dye labels and QSY quenchers to provide detection of 3 targets and ROX dye as a passive reference in a single reaction. Figure 5 demonstrates the performance of in a 3-plex experiment using DNA from dried blood on filter paper to detect 3 targets simultaneously: T cell receptor excision circles (TREC) with FAM dye, kappa-deleting recombination excision circles (KREC) with VIC dye, and the endogenous control gene RPPH (RNaseP) labeled with ABY dye. TaqPath ProAmp Multiplex Master Mix also allows use of a fourth probe with JUN dye and Mustang Purple dye as a passive reference dye. These dyes are optimized to work together in both formulations of the master mix with minimal spectral overlap for optimal performance. Inhibitor tolerance Unlike other master mixes on the market, the unique proprietary formulation of TaqPath ProAmp Master Mix enables reproducibly accurate performance even in the presence of substances that normally inhibit PCR, such as heparin, EDTA, and sodium citrate, increasing your 0 0. 0.0 0.00 Amplification Plot confidence when working with a variety of complex clinical samples. Figure 6 depicts the enhanced performance of TaqPath ProAmp Master Mix in the presence of two common inhibitors, in comparison with two other commercial master mixes. 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 4 44 TREC (FAM-QSY) RNaseP (ABY-QSY) KREC (VIC-MGB) Figure 5. Multiplex PCR. Applied Biosystems TaqMan Gene Expression Assays** were used in a 3-plex experiment targeting TREC with a FAM QSY probe, KREC with a VIC MGB/NFQ probe, and RNaseP (endogenous control gene) with an ABY QSY probe. The Applied Biosystems DNA Extract All Reagents Kit was used to extract DNA in 3 minutes from a mm filter paper containing dried blood. A 5 μl volume of stabilized solution prepared with the DNA Extract All Reagents Kit was used in a 0 μl qpcr reaction with. 0 0 0 Supplier K 0. 0. 0. 0.0 0.0 0.0 0.00 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 0.00 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 0.00 4 6 8 0 4 6 8 0 4 6 8 30 3 34 36 38 40 Figure 6. Inhibitor tolerance of and other commercial master mixes. Crude lysates of blood samples isolated in sodium citrate (green), EDTA (red), or heparin (blue) Vacutainer tubes were used in the experiment and constituted 30% of reaction volume. Eight replicate genotyping reactions were run to assess the magnitude and standard deviation of C t values in the presence of these PCR inhibitors. Amplification plots for reactions are shown. yields lower C t values in the presence of inhibitors, and lower standard deviation for replicates. No amplification was observed using Supplier K s mix with the heparin-containing sample.

Manufacturing production and process controls With established controls from purchasing through QC release, the manufacturing of TaqPath products is designed to deliver consistent performance across multiple lots. Figure 7 demonstrates that lot-to-lot consistency of C t is preserved across multiple samples at the same target levels. 30 5 0 Lot 3 Broad instrument compatibility can be used in either fast or standard cycling conditions with equivalent performance across a wide variety of real-time PCR systems, including Applied Biosystems qpcr platforms (e.g., 7500, 7500 Fast, and 7500 Fast Dx systems; QuantStudio 3, 5, 6 Flex, 7 Flex, K Flex, and Dx systems; ViiA 7 system).** General purpose reagents TaqPath master mixes are general purpose reagents manufactured in an ISO 3485 certified facility and labeled For Laboratory Use. TaqPath master mixes are part of the TaqPath general purpose reagents product line, which includes: TaqPath qpcr Master Mix, CG includes ROX passive reference dye C t 5 0 5 0 3 Lot Figure 7. Consistency of C t across multiple assays for three unique lots of. Genomic DNA was analyzed using the Applied Biosystems TaqMan Copy Number Reference Assay** for RNase P and three distinct lots of on a panel of 3 DNA samples. Mean C t values for each lot are shown with error bars representing one standard deviation; the standard deviations for lots,, and 3 were 0.99, 0.55, and 0.78, respectively. Excellent C t concordance was seen across the three lots, and copy number values were 00% concordant across all lots tested with 0 assays, 3 samples, and 4 replicates per assay/sample combination. TaqPath -Step RT-qPCR Master Mix, CG includes ROX passive reference dye TaqPath -Step Multiplex Master Mix includes Mustang Purple passive reference dye TaqPath -Step Multiplex Master Mix (No ROX) does not include a passive reference dye TaqPath ProAmp Master Mix includes ROX passive reference dye TaqPath ProAmp Multiplex Master Mix includes Mustang Purple passive reference dye

Ordering information Product Reactions Quantity Cat. No. 00 x ml A30865,000 x 0 ml A30866 4,000 x 0 ml A3087 0,000 x 50 ml A30867 0,000 x 50 ml A3087, evaluation samples 00 x ml A3704 00 x ml A30868,000 x 0 ml A30869 TaqPath ProAmp Multiplex Master Mix 4,000 x 0 ml A30873 0,000 x 50 ml A30870 0,000 x 50 ml A30874 TaqPath ProAmp Multiplex Master Mix, evaluation samples 00 x ml A3705 Find out more at thermofisher.com/proamp * Dynamic range is a property of both the assay and template concentration in the sample, as well as the formulation of the master mix; thus, individual results may vary. ** TaqMan Assays and probes, 7500, 7500 Fast, and ViiA 7 Real-Time PCR Systems, as well as QuantStudio 5, 6 Flex, 7 Flex, and K Flex Real-Time PCR Systems are for Research Use Only. TaqPath master mixes are For Laboratory Use. For Laboratory Use. 06 Thermo Fisher Scientific Inc. All rights reserved. All trademarks are the property of Thermo Fisher Scientific and its subsidiaries unless otherwise specified. TaqMan is a registered trademark of Roche Molecular Systems, Inc., used under permission and license. Vacutainer is a trademark of Beckton, Dickinson and Company. COL33 096