ESU-150. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

Similar documents
ESU-130. Thin-line Louver Thin-line Blade. Application and Design. Standard Construction. Options (at additional cost)

ESF-145. Thin-line Louver Flat Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-154. Thinline Louver Thinline Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-153. Thinline Louver Thinline Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-154. Thinline Louver Thinline Blade. Application and Design. Standard Construction. Options (at additional cost)

ESU-130S. Thin-line Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

ESID-430. Intake/Discharge Specialty Louver Stationary Blades. Application and Design

ESU-154S. Thinline Louver Frameless. Application and Design. Standard Construction. Options (at additional cost)

ESJ-202. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

ESJ-401. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

ESJ-401RM. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

EDK-402. Stationary Louver K Blade. Application and Design. Standard Construction. Options (at additional cost)

EDJ-401. Stationary Louver J Blade. Application and Design

EDJ-202. Stationary Louver J Blade. Application and Design

ESD-202. Stationary Louver Drainable Blade. Application and Design

ESD-403. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

EDD-401. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

ESD-635. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

VASJ-6. Stationary Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

EDD-601. Stationary Louver Dual Drainable Blade. Application and Design. Standard Construction

EHM-601. Hidden Mullion Louver Dual Drainable Blade. Application and Design

SED-501. Sightproof Louver Drainable Blade. Application and Design

ESD-435. Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

AFJ-601. Acoustical Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

ECD-601. Combination Louver/Damper Drainable Blade. Application and Design. Standard Construction

EVH6. Wind-Driven Rain Louver Vertical Blade. Application and Design. Standard Construction. Options (at additional cost)

EHH-401. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost)

EVH-602. Wind-Driven Rain Louver Vertical Blade. Application and Design. Standard Construction. Options (at additional cost)

EHH-501. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost)

EVH-501. Wind-Driven Rain Louver Vertical Blade. Application and Design. Standard Construction. Options (at additional cost)

EAH-690. Adjustable Louver J Blade. Application and Design. Standard Construction. Options (at additional cost)

EVH-501. Wind-Driven Rain Louver Vertical Blade. Application and Design. Standard Construction. Options (at additional cost)

AFA-801. Acoustical Louver Airfoil Blade. Application and Design. Standard Construction. Options (at additional cost)

EHH-401. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost)

EHH-201. Wind-Driven Rain Louver Horizontal Blade. Application and Design. Standard Construction. Options (at additional cost)

EACA-601. Combination Louver/Damper Airfoil Blade. Application and Design. Standard Construction

EACC-601. Combination Louver/Damper Concealed Actuator. Application and Design. Standard Construction

EAD-401. Adjustable Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

EAC-401. Combination Louver/Damper Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

FSJ-602. Fabricated Steel Stationary Louver J Blade. Application and Design

FSJ-402. Fabricated Steel Stationary Louver J Blade. Application and Design

EHV-901. Wind-Driven Rain Louver Dual Module. Application and Design. Standard Construction. Options (at additional cost)

EAD-601. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

EAC-601. Combination Louver/Damper Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

FSJ-402. Fabricated Steel Stationary Louver J Blade. Application and Design

EAD-635. Adjustable Louver Drainable Blades. Application and Design. Standard Construction. Options (at additional cost)

VAVH-5. Wind-Driven Rain Louver Vertical Blade. Application and Design. Standard Construction. Options (at additional cost)

FDS-602. Fabricated Steel Stationary Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

VACC-4. Combination Louver/Damper Drainable Blade. Application and Design

VAAD-6. Adjustable Louver Drainable Blades. Application and Design

AFJ-601D. Miami-Dade Qualified Acoustical Louver. Application and Design. Standard Construction. Options (at additional cost)

ESD-603D. Miami-Dade Qualified Drainable Blade Louver. Application and Design. Standard Construction. Options (at additional cost)

EVH-660D. Miami-Dade Qualified Wind-Driven Rain Louver. Application and Design. Standard Construction. Options (at additional cost)

Miami-Dade Qualified Drainable Blade Louvered Penthouse

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

FAD-402. Fabricated Steel Adjustable Louver Drainable Blade. Application and Design. Standard Construction. Options (at additional cost)

ESD-435X. Florida Product Approved Drainable Blade Louver. Application and Design. Standard Construction. Qualified Shapes

EVH-660D. Miami-Dade Qualified Wind-Driven Rain Louver. Application and Design. Standard Construction. Options (at additional cost)

EACA-601D. Miami-Dade Qualified Combination Louver

Stationary Louvers. Product Type Model Description EDD-401, 601 ESD-202, 403, 435, 603, 635 EDJ-202, 401, 430, 601 EDK-402, 430, 602 ESID-430

SCV501MD Florida Product Approval No.: Miami-Dade, FL NOA No.: , EXP. 8/6/2020 Maximum Wind-Load: 130 PSF

K6746X Florida Product Approval No.: FL7708.2, UL Classified: R25376

K6746PD Florida Product Approval No.: Miami-Dade NOA No.: , EXP. 6/19/23

Florida Product Approval No.: FL Miami-Dade, FL NOA No.: , EXP. 12/7/16. Visible Mullion Louver Type... SCV602MD

6 Drainable Louver. Update to Louvers Catalog C-1.0. Catalogue Page 2 Page 7. Page LP-13. Submittals Drawing

SCV602MD Florida Product Approval No.: FL Miami-Dade, FL NOA No.: , EXP. 12/7/16 TDI Approval No.: LVR-05

Louvers Selection, Design Considerations and Details Written by Matt Trentham, R.L. Craig Company, Inc.

EHH-601D. Miami-Dade Qualified Wind-Driven Rain Louver

WIND-DRIVEN RAIN LOUVER MODEL LE-36

LOUVERS ACOUSTICAL BRICK VENT COMBINATION DRAINABLE EQUIPMENT SCREENS FORMED METAL NON-DRAINABLE OPERABLE PENTHOUSE SAND LOUVER WIND-DRIVEN RAIN

LOUVER PRODUCTS. Architectural Blade Louvers Drainable Blade Louvers Wind-Driven Rain Louvers Sightproof Louvers Acoustical Louvers Thinline Louvers

LOUVERS GENERAL PRODUCT OVERVIEW

10200/ARR Buyline 4822 ARROW LOUVERS. The Preferred Line PUBLICATION

ELM6375DX DRAINABLE ADJUSTABLE LOUVER EXTRUDED ALUMINUM

Ruskin model ELF375X with 5/8" 0.40 aluminum bird screen and Baked Enamel Finish to Match

LC-1250, LM-1250, LV-1250, LV-1251, and LV-1800 Louvers

SafidLouvers. Sand Trap Louver STL STL STL Construction Standard STL STL STL Optional Extras

LOUVERS TABLE OF CONTENTS. Page No.

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

EME6325D WIND-DRIVEN RAIN RESISTANT STATIONARY LOUVER

SECTION E INDEX CURTAINWALL FRAMING SYSTEMS

ELF6375DXD DRAINABLE STATIONARY LOUVER

Acoustic Louvers ABSORPTIVE ACOUSTIC LOUVERS

SPECIFICATION SECTION PART 1 GENERAL

ELF6375DXD DRAINABLE STATIONARY LOUVER

PART 1 GENERAL 1.04 Quality Assurance

TMW 450 TECHNICAL MANUAL

SECTION SHOP-APPLIED METAL FINISHES

TMS 152 / 152T / 152XT TECHNICAL MANUAL

SPECIFICATION SECTION PART 1 GENERAL

A. This Section includes ceiling- and wall-mounted diffusers, registers, grilles and louvers.

TMS 114 XT TECHNICAL MANUAL

SPECIFICATION SECTION PART 1 GENERAL

SPECIFICATION SECTION PART 1 GENERAL

SPECIFICATION SECTION PART 1 GENERAL

SPECIFICATION SECTION PART 1 GENERAL

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

Wall Louvers (10200)

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

Brise Soleil Fixed Sunshades

Transcription:

Application and Design Thin-line Blade is a thin-line stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into curtainwalls, windows, doors, or as air conditioning grilles. Standard Construction Frame........Heavy gauge extruded 6063T5 aluminum, 1 ½ in. x 0.063 in. nominal wall thickness Blades........Thin-line style, heavy gauge extruded 6063T5 aluminum, 0.063 in. nominal wall thickness, positioned at 52º angles on approximately ¾ in. centers Finish.........Mill Minimum Size..13.5 in. W x 10 in. H (without fl ange) 13.5 in. W x 12 in. H (with fl ange) Maximum Single Section Size...96 in. W x 48 in. H Options (at additional cost) A variety of bird and insect screens Anchor brackets Captivated frame Extended sill Flanged frame Glazing adaptor A variety of architectural finishes including: Clear anodize Integral color anodize Baked enamel paint Kynar paint *Width and height dimensions furnished approximately ¼ inch under size.

PERFORMANCE DATA Free Area Chart (Sq. ft.) Louver Louver Width in Inches Height Inches 10 12 18 24 30 36 42 48 54 60 66 72 78 84 90 96 10 0.18 0.24 0.41 0.60 0.78 0.97 1.15 1.34 1.47 1.66 1.84 2.03 2.23 2.34 2.53 2.72 12 0.22 0.30 0.51 0.74 0.97 1.20 1.43 1.67 1.83 2.06 2.29 2.52 2.78 2.92 3.15 3.38 15 0.28 0.38 0.66 0.95 1.25 1.55 1.85 2.14 2.35 2.65 2.95 3.25 3.58 3.75 4.05 4.35 18 0.35 0.47 0.80 1.17 1.53 1.89 2.26 2.62 2.88 3.24 3.61 3.97 4.38 4.59 4.95 5.32 21 0.41 0.55 0.95 1.38 1.81 2.24 2.67 3.10 3.41 3.83 4.26 4.70 5.17 5.43 5.86 6.29 24 0.47 0.64 1.10 1.59 2.09 2.59 3.08 3.58 3.93 4.43 4.92 5.42 5.97 6.27 6.76 7.26 27 0.54 0.72 1.24 1.81 2.37 2.93 3.50 4.06 4.46 5.02 5.58 6.15 6.77 7.11 7.67 8.23 30 0.60 0.81 1.39 2.02 2.64 3.27 3.90 4.53 4.97 5.60 6.23 6.86 7.56 7.93 8.56 9.18 33 0.66 0.89 1.53 2.23 2.92 3.62 4.31 5.01 5.50 6.19 6.89 7.58 8.36 8.77 9.46 10.16 36 0.72 0.98 1.68 2.44 3.20 3.96 4.72 5.49 6.02 6.78 7.54 8.31 9.16 9.61 10.36 11.13 39 0.79 1.06 1.83 2.65 3.48 4.31 5.14 5.96 6.55 7.37 8.20 9.03 9.96 10.44 11.27 12.10 42 0.85 1.15 1.97 2.87 3.76 4.65 5.55 6.44 7.08 7.87 8.86 9.76 10.76 11.28 12.17 13.07 45 0.91 1.23 2.12 3.08 4.04 5.00 5.96 6.92 7.60 8.56 9.52 10.48 11.55 12.12 13.08 14.04 48 0.98 1.32 2.27 3.29 4.32 5.34 6.37 7.40 8.13 9.15 10.18 11.21 12.35 12.96 13.98 15.01 Airflow Resistance (Standard Air -.075 lb/ft 3 ) Pa 200 in. wg 1 0.9 0.8 0.7 0.6 0.5 Test Size 48 in. x 48 in. Standard Air -.075 lb/ft 3 100 90 80 70 60 0.4 0.3 Static Pressure Drop 50 40 30 20 0.2 0.1 0.09 0.08 0.07 Exhaust Intake This half intentionally left blank. 0.06 0.05 10 9 0.04 8 7 0.03 6 5 0.02 ft/min 200 300 400 500 600 700 800 900 1000 2000 3000 m/s 2 3 4 5 6 7 8 9 10 Free Air Velocity Model resistance to airflow (pressure drop) varies depending on louver application (air intake or air exhaust). Free area velocities (shown) are higher than average velocity through the overall louver size. See louver selection information.

INSTALLATION DETAILS Maximum Size and Installation Information Maximum single section size for model is 96 in. W x 48 in. H. Larger openings require field assembly of multiple louver panels to make up the overall opening size. Individual louver panels are designed to withstand a 25 PSF wind-load (please consult Greenheck if the louvers must withstand higher wind-loads). Structural reinforcing members may be required to adequately support and install multiple louver panels within a large opening. Structural reinforcing members along with any associated installation hardware is not provided by Greenheck unless indicated otherwise by Greenheck. Additional information on louver installation may be found in AMCA Publication #501, Louver Application Manual. Minimum Single Section Size 13.5 in. W x 10 in. H (without flange) 13.5 in. W x 12 in. H (with flange) Maximum Single Section Size 96 in. W x 48 in. H

PRODUCT DETAILS

OPTION DRAWINGS FINISHES Finish Type Description/Application Color Selection Standard Warranty (Aluminum) 2-coat 70% KYNAR 500 /HYLAR 5000 AAMA 2605 Dry film thickness 1.2 mil. (AKA: Duranar, Fluoropon, Trinar, Flouropolymer, Polyvinylidene Fluoride, PVDF2) Best. The premier finish for extruded aluminum. Tough, long-lasting coating has superior color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Standard Colors: Any of the 24 standard colors shown can be furnished in 70% or 50% KYNAR 500 /HYLAR 5000 or Baked Enamel. 10 Years (Consult Greenheck for availability of extended warranty) 2-coat 50% KYNAR 500 /HYLAR 5000 AAMA 2604 Dry film thickness 1.2 mil. (AKA: Acroflur, Acrynar ) Baked Enamel AAMA 2603 Dry film thickness 0.8 mil. (AKA: Acrabond Plus, Duracron ) Better. Tough, long-lasting coating has excellent color retention and abrasive properties. Resists chalking, fading, chemical abrasion and weathering. Good. Provides good adhesion and resistance to weathering, corrosion and chemical stain. 2-Coat Mica: Greenheck offers 9 standard 2- coat Mica colors. Other colors are available. Consult Greenheck for possible extra cost when selecting non-standard colors or special finishes. 5 Years 1 Year Integral Color Anodize AA-M10C22A42 (>0.7 mil) Clear Anodize 215 R-1 AA-M10C22A41 (>0.7 mil) Clear Anodize 204 R-1 AA-M10C22A31 (0.4-0.7 mil) Industrial coatings Mill Two-step anodizing is produced by following the normal anodizing step with a second, colorfast process. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Clear, colorless and hard oxide aluminum coating that resists weathering and chemical attack. Light, Medium or Dark Bronze; Champagne; Black Clear Clear Greenheck offers a number of industrial coatings such as Hi-Pro Polyester, Epoxy, and Permatector. Consult a Greenheck Product Specialist for complete color and application information. Materials may be supplied in natural aluminum or galvanized steel finish when normal weathering is acceptable and there is no concern for color or color change. 5 years 5 years 1 Year Consult Greenheck Finishes meet or exceed AAMA 2605, AAMA 2604, and AAMA 2603 requirements. Please consult www.greenheck.com for complete information on standard and extended paint warranties. Paint finish warranties are not applicable to steel products. n/a July 2007 Rev. 4 Copyright 2007 Greenheck Fan Corporation Greenheck Fan Corporation reserves the right to make product changes without notice.