Thermo-Lag E100. Epoxy Intumescent Fireproofing

Similar documents
Coatings - Linings - Fireproofing. Thermo-Lag E100. Epoxy Intumescent Fireproofing

Coatings - Linings - Fireproofing. Thermo-Lag E100. Epoxy Intumescent Fireproofing

A/D Firefilm III PRODUCT DATA SHEET

Thermo-Lag E100 S PRODUCT DATA SHEET

Thermo-Lag E100. Epoxy Intumescent Fireproofing

How Passive Fire Protection (PFP) Works

International Fireproof Technology Inc.

A two component, 100% solids epoxy based intumescent coating. Aesthetics can be improved by trowel and back rolling.

*Aesthetics can be improved by trowel and back rolling. Use FP-Fiberglass Mesh or High Temp Mesh depending on design.

*Aesthetics can be improved by trowel and back rolling ft² at 1 mil (149 m² at 25 microns)

International Fireproof Technology Inc.

*Aesthetics can be improved by trowel and back rolling ft²/gallon at 1 mil (38 m²/liter at 25 microns)

SECTION INTUMESCENT FIREPROOFING

ARCHITECTURAL SPECIFICATION

SECTION INTUMESCENT MASTIC FIREPROOFING

SYSTEM. decorative fire protection FOR ON-SITE & OFF-SITE APPLICATION. FOR STRUCTURAL STEEL external and internal use

3MTM FireDamTM Intumescent Coating WB Installation Manual. Thinner is. Better

HEMPACORE. Passive Fire Protection

SECTION (07810) - APPLIED FIREPROOFING

Intumescent Coatings for Commercial Infrastructure

Tnemec Fluid Applied Thermal Break Long Form Specification

Request for Information (RFI) - 52

A. Section includes Sprayed Fire-Resistive Materials: (SFRM) A. Pre-Installation Conference: Conduct conference at Project Site.

NFCA 400 Field Quality Assurance Procedure for Application of Mastic and Thin-Film Intumescent Fire Resistive Coatings

Property Test/Standard Description Solids by volume. ISO 3233 Flash point ISO 3679 Method 1 VOC-US/Hong Kong US EPA method 24 (tested)

fireshieldcoatings.com

Life Hall Renovation Issued: July 9, 2014 Montclair State University Addendum No. 1 Owner's Project No Cannon Design Project No

STRUCTURAL STEEL FIRE PROTECTION INTUMESCENT COATINGS SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: APPLIED FIREPROOFING REPORT HOLDER: CARBOLINE COMPANY

POLYURETHANE COATINGS ON STEEL OR DUCTILE IRON PIPE

DIVISION: CONCRETE SECTION: MAINTENANCE OF CONCRETE REPORT HOLDER: STRUCTURAL TECHNOLOGIES, LLC

DRAFT - MOCA STANDARD for Fiber-Reinforced Magnesium Cement Board

Pacific Polymers Elasto-Deck 5000MR Guide Specification

FIRETEX FX Systems. Cellulosic Passive Fire Protection

Aesthetically pleasing and durable options for finishing walls and ceilings. Aesthetic

HEAT-FLEX HI-TEMP 1200 Coating Under Insulation

PRODUCT SPECIFICATIONS

FLEXMAR 3-Coat High-Build Colored Quartz System

Protective & Marine Coatings Europe, Middle East, Africa & India

DATASHEET: FIRECUT F-1 (EXTERIOR) SPRAY-APPLIED FIRE RESISTIVE MATERIALS

A. This Section includes traffic coatings for the following applications:

FABRICATED FIREPROOFED STEEL COLUMNS

CHARTEK 1709 FIREPROOFING INSTALLATION PROCEDURE

Florock Seamless Flooring Systems

Protective & Marine Coatings Europe, Middle East, Africa & India

3,Rothwell Street, Timaru, South Canterbury. ; : Phone or

First Class Building Products, Inc.

MANUFACTURER S (SHORT FORM) SPECIFICATION / SECTION

MANUFACTURERS (SHORT FORM) SPECIFICATION / SECTION

RESINOUS FLOORING

RECOMMENDED DESIGN SPECIFICATION

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

Typically used in the oil, gas and energy industries. Suitable for both offshore and onshore environments.

Application Guide. Steelmaster 1200WF. Intumescent Coating

CUSTOM BRICK. Custom Brick Finish Polymer System Specifications For Use On Vertical Walls DS151. Architectural Finish for Use on Vertical Walls

PERM-FLEX (JC) ASSEMBLY DIRECT APPLICATION TO CEMENT BOARD SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION STRUCTURAL METAL FRAMING

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

IFTI - Master Specification Section <IssueDate> Rev. June 2018

Structural Steel Fire Protection Advanced Intumescent Technology

Intumescent Fire Protection Solutions for Structural Steel

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

1/16 Single Broadcast Polymer Flooring System

Pyrocrete 240 High Yield

Solventless, two-component, cross-linked epoxy. Epoxies lose gloss, discolour and eventually chalk in sunlight exposure.

TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

Solventless two-component crosslinked epoxy

high-performance coatings for commercial spaces.

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

Pacific Polymers Elasto-Deck BT Guide Specification

Section Shotcrete

PERFORMANCE, 100% SOLIDS,

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

THERMO-LAG E100 / THERMO-LAG E100 S. Fire Barrier System Application Manual. Commercial / Light Industrial Market ASTM E119 (UL 263 / NFPA 251)

Intumescent Coatings and Spray Polyurethane Foam

Innovative Coatings Technologies

High Strength LITE Gypsum Board

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

FIRETEX Hydrocarbon Series. Epoxy Passive Fire Protection

Food Service FDA Title 21 CFR

Industrial Fireproofing. System Guide. High Density Cementitious Epoxy Intumescent Electrical Cable Fireproofing Epoxy Syntactic Insulation

PROLINE MID-TEMPERATURE VINYL ESTER LINING INSTALLATION GUIDE ProLine 4865T with optional 4822S Gel Coat Food Service FDA Title 21 CFR 175.

Broadcast Parking Garage System

SECTION TILT-UP PRECAST CONCRETE SANDWICH PANELS. A. Work includes, but is not limited to, the following:

A. ASTM C 150 Standard Specification for Portland Cement. B. ASTM C 595 Standard Specification for Blended Hydraulic Cements.

STRUCTURAL STEEL FRAMING

Refer to Substrates & Surface Preparation.

Innovative Coatings and Linings Technology for Rail Cars. Vijay Datta MS, International Paint LLC and Mike O Donoghue, PhD

TECHNICAL BULLETIN. Recommended Levels of Finish for Paper-Faced Gypsum Board

SECTION EPOXY MOSAIC COMPOSITION FLOORING Dex-O-Tex Cheminert Terracolor

Vapor-Clear. The high-performance, low-cost, eco-friendly, aesthetically-pleasing alternative to high-build epoxy floors and boring

GigaCrete Specification PlasterMax

PRODUCT DATA SHEET Sika Unitherm Platinum

Galvanized Steel Bead Accessories for Stucco and Plaster Installations ALABAMA METAL INDUSTRIES CORPORATION. Contract Number:

GUIDE SPECIFICATION SECTION 07576

ICC-ES Evaluation Report Reissued December 1, 2011 This report is subject to renewal in two years.

EDGEWATER, FLORIDA JUNE 14, 2010

Refer to Substrates & Surface Preparation.

SECTION EPOXY FLOORING SYSTEMS

Transcription:

Thermo-Lag E100 Epoxy Intumescent Fireproofing

Thermo-Lag E100 is an epoxy intumescent fireproofing system with an advanced formulation eliminating the need for a mesh reinforcement layer. It was specifically designed to provide 1-3 hour cellulosic fire protection for commercial structural steel. Benefits of Thermo-Lag E100 Certified to UL 263/ASTM E119/NFPA 251/CAN/ ULC S 101-07 up to 3 hours Most efficient epoxy intumescent in the industry Self reinforced, no mesh needed Saves application time, high film build, fast cure Rated for exterior and interior use LEED compliant Easy to apply, 1:1 mix ratio Highest quality aesthetics Applications Commercial buildings Light industrial facilities Clean rooms Manufacturing plants Factories and warehouses Stadiums and convention centers Airport terminals Museums

Thermo-Lag E100 is a tough, durable material that can deliver lasting physical performance. It is the ideal solution for both onsite and offsite application, providing the ultimate in design flexibility and enhanced project scheduling. ON-SITE TIME AND LABOUR SAVINGS 1 2 3 4 5 6 COMPLETE up to 60% faster application Thermo-Lag E100 can be applied up to 200 mils per day, most projects are complete in two days. COMPLETE Competitor water based intumescent can take up to six days to complete. Offsite Speed and Durability Fast application and shop throughput Hard, durable material resistant to damage High flexural strength High quality finish in less time Connections are easily fireproofed onsite

Thermo-Lag E100 saves lives and assets. When exposed to a fire it intumesces or swells, producing a heat blocking char which insulates the steel from exposure to high temperatures. This allows more time for people to exit and firefighters to respond. APPLICATION PROPERTIES THERMO-LAG E1O0 THERMO-LAG E100 S Construction Phase Offsite Onsite or Offsite Recoat Time 30 Min 4 Hrs Volume Solids 100% 95% Film Build (Per Coat) 60-200 Mils (1.5-5Mm) 60-120 Mils (1.5-3Mm) Application Method Plural Component Trowel Plural Component Trowel Single Component Trowel PERFORMANCE DATA Prepared Steel Hardness (ASTM D2240) >Shore D 60 Primer Impact Resistance (ASTM D2794) 0.75 ft. lbs/in Thermo-Lag E100 Bond Strength (ASTM D4541) Compressive Strength (astm d695) Flexural Strength (astm d790) Surface Burning (astm e84) >1,200 psi (>8.2 Mpa) >2,330 psi (>16 MPa) >1,220 (>8.4 MPa) Class A Topcoat Thermo-Lag E100 System is an easy to apply three step process, with no mesh required. Its high film build and fast cure characteristics make it an excellent choice when time is critical.

UL Environmental Testing Thermo-Lag E100 is in full compliance with the acceptance criteria for the UL Environmental Test Program and is rated by UL and Intertek for both exterior and interior use. Certifications Thermo-Lag E100 has undergone extensive third-party testing, and is certified in accordance to UL 263/ASTM E119/NFPA 251/CAN/ULC S 101-07. It offers 1-3 hour cellulosic fire protection for: Restrained/unrestrained beams I-section columns Tubular columns Pipes

Thermo-Lag E100 Finish Levels Choosing the Right Finish This guide provides architects options to select and clearly define the needed aesthetic level for a project and describes the application techniques required. It is always good practice to produce a representative sample which should be used as the quality standard for the project. LEVEL 1 Standard Finish (Spray Applied and Minimal Back Rolling) LEVEL 2 Commercial Finish (Spray Applied and Back Rolled) Definition Definition Standard sprayed finish applied to specified DFT requirements with surface irregularities. Surface has a textured appearance. Procedures Spray application with airless equipment. Surface is left as sprayed with hand tooling or back rolling on edges only. Suggested Use Areas where surface appearance is not of primary concern or not visible such as, mechanical rooms, parking garages, and light industrial applications. Sprayed and back rolled finish applied to specified DFT requirements with some surface irregularities. Uniform, light texture with minimal surface defects. Procedures Spray application with airless equipment. Surface is then back rolled to smooth high points and surface defects. Back rolling/hand tooling are required on flanges and angles. Material must be applied in a consistent manner with lighter coats. This will maintain the best possible finish prior to any secondary surface finishing. Suggested Use Visible areas where a uniform texture and an upgrade from a Level 1 Finish is desired.

Thermo-Lag E100 is used on many projects where surface finish and aesthetics are important. A high quality surface finish is easy to obtain with Thermo-Lag E100. There are a range of finish levels that can be achieved depending on requirements and the aesthetics desired. LEVEL 3 Architectural Finish (Spray Applied, Back Rolled and Sanded) LEVEL 4 High Quality Architectural Finish (Spray Applied, Back Rolled and Sanded Smooth) Definition Definition Spray applied to specified DFT requirements, back rolled and sanded. Some slight texture visible. Uniform appearance with minimal surface defects. Procedures Spray application with airless equipment. Surface is then back rolled to smooth high points and surface defects. Back rolling and hand tooling are required. Surface is then sanded to minimize texture. Material must be applied in a consistent manner with lighter coats. This will maintain the best possible finish prior to any secondary surface finishing. Suggested Use Areas with high visibility where high quality finish is desired. Spray applied to specified DFT requirements, back rolled and sanded. No texture visible. Uniform smooth appearance with no surface defects. Surface shall be smooth and free of tool marks and ridges. Procedures Spray application with airless equipment. Surface is then back rolled to smooth high points and surface defects. Back rolling and hand tooling are required. Surface is then sanded smooth to eliminate orange peel texture. Material must be applied in a consistent manner with lighter coats. This will maintain the best possible finish prior to any secondary surface finishing. Suggested Use Areas where highest quality finish is desired. Application Considerations It is important to understand that application time and labour required will increase with higher finishing levels. Carboline is not responsible for determining what finish is acceptable. The level of finish achieved will depend on: experience of the applicator, ambient conditions, application method and equipment, access to steel, size and configuration of steel structure.

CANADIAN SALES & DISTRIBUTION LOCATIONS CARBOLINE HEAD OFFICE 95 SUNRAY ST. WHITBY, ON L1N 9C9 PHONE: 877.393.3303 WWW.CARBOLINE.CA #4158-08/14