DATA SHEET AUTOMATED MEMBRANE SOLUTION FOR SMALL SCALE WATER TREATMENT

Similar documents
PRO. Safe, clean drinking water on tap anywhere, anytime with UF-PRO Ultrafiltration Units...

SkyHydrant-MAX. SkyHydrant-GEM. Nominal 6,000 litres per day Height - 82 cm Depth - 18 cm Width - 25 cm Mass (dry) - 9 kg Mass (wet) - 21 kg

AQUAVENDOR AUTO. Ultrafiltration Unit SETUP OPERATING INSTRUCTIONS

OPERATING & MAINTENANCE MANUAL

ULTRAFILTRATION UNIT POD - USER INFORMATION GUIDE & DATA SHEET. Cluster and Small Community Safe Water Filtra4on unit SPOD.

MEMCOR MEMBRANES FOR DRINKING WATER APPLICATIONS

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

REVERSE OSMOSIS WATER TREATMENT

Reverse Osmosis Desalinators

The Basics. Reverse Osmosis is a process that is used to remove. Front Side 1. Controller

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s].

Purite Water Purification Systems

PedalPure The Portable Ultra-Filtration Water Treatment System

AQpure. water treatment systems COMMUNITY WATER SUPPLY MODULAR AND AUTOMATED ULTRAFILTRATION WATER TREATMENT FOR SUSTAINABLE DRINKING WATER

Trident. Package Water Treatment System

A NEW MEMBRANE FILTRATION PLANT FOR GIRGARRE. Geoffrey Frost. Geoffrey Frost, Principal Water Engineer, Parsons Brinckerhoff Australia P/L

Aqua-Recycling-Control 80B Plus

U-Version. Incoming City Water

PRIMARY GRADE WATER L A B W A T E R. PURELAB TM Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Reclamation of Sand Filter Backwash Effluent using HYDRAcap LD Capillary UF Membrane Technology

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

PRIMARY GRADE WATER. PURELAB Prima. Primary Grade Water Purification Systems. The Laboratory Water Specialists

Cl500/Cl1000 BROCHURE

W O C H H O L Z R E G I O N A L W A T E R R E C L A M A T I O N F A C I L I T Y O V E R V I E W

We are a leader in renewable energy powered water treatment systems.

Ultrafiltration Technical Manual

Systems. Barnstead MIX AND MATCH...WITH BARNSTEAD YOU HAVE A CHOICE

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids

R.O water vending machine (USER MANUAL)

Membrane Technique MF UF NF - RO

PureBallast. Ballast water treatment system

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

PRODUCTS CATALOGUE. Solar powered desalination and water purification

Akiki Engineering Est.

Puroxi Pure Water Global Inc. Shield 500/1000 Drinking Water System (DWS)

For Safe and Delicious Water

Improved Membrane Design Addresses Integrity Issues for the City of Yuba City Water Treatment Plant

Recent Advances in Membrane Technologies Peter D Adamo, Ph.D., P.E Spring Conference Wilmington, NC April 13, 2015

HUBER Vacuum Rotation Membrane VRM Bioreactor

HYUNDAI MIRO-3A. Address: , Gongreung-Dong, Nowon-Ku, Seoul, Korea Tel) Fax) Homepage:

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

PSP Series Water Purification Systems

Commercial Reverse Osmosis System

MICRODYN-NADIR. MICRODYN isep 500 Ultrafiltration Modules. Product Manual. Product Manual

RC400G FC400G RESIDUAL CHLORINE ANALYZER RC400G NON-REAGENT FREE CHLORINE ANALYZER FC400G RESIDUAL CHLORINE ANALYZER

PURELAB Chorus. Solutions for Type I Ultrapure Water

ANIMAL SOLUTIONS LIGHTING CONTROL ENVIRONMENTAL MONITORING AUTOMATED WATERING V.2 WIRELESS VALIDATION. An ISO 9001:2000 Company

Make Water Anywhere with Pall Integrated Membrane Systems

Innovative concept for Ultrafiltration systems: Integration of ultrafiltration cartridges and strainer in a single vessel

rios Water Purification system The standard for laboratory-grade water

Membrane Systems. Featuring Aqua MultiBore Membranes

ULTRAFILTRATION UNIT

MBR System KD 40. Recycle Water - Technical Water/ Replacement for Clarifiers Watch Product Video

PURELAB Chorus. Solutions for Type I Ultrapure Water

OLTRE CAP V- SERIES OUTSIDE IN AIR SCOUR ULTRAFILTRATION MEMBRANES

Q45WQ. Water Quality Monitoring System. 6 Iron Bridge Drive Unit 1 & 2 Gatehead Business Park

AQpure. water treatment systems RAINWATER HARVESTING

AstroBoy Quick install guide

A. This section includes the requirements for the following chemical feed systems:

flow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow

Pall Aria System Rescues Bottled Spring Water Producer from Plant Closure

HIGH-CAPACITY ULTRAFILTRATION ENGINEERING GUIDE

Pora. A Host of Latest Water Membrane Technologies

Product Description / Equipment Specifications FlowMAX Reverse Osmosis Products FM Horizontal Pump Series

Technical Specification Industrial Series - IS2 to IS48 Systems. CapDI Benefits. Feed Water Quality. Design and Scope of Supply.

Zero Liquid Discharge Project Extends Potable Water Supplies

OPERATION AND MAINTENANCE MANUAL UF-6-HF ULTRAFILTRATION SYSTEM

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

PURELAB CHORUS SYSTEMS

RiOs Essential 5, 8, 16, 24 Water Purification Systems

Low Pressure Membrane Filtration System Operations

Demineralisation. PUROTAP expert. Installation Function Operation Service. Demineralised heating water.

DRINKING WATER CONDITIONERS WATER PURIFIERS U.V. STERILIZERS REVERSE OSMOSIS GELPUR FILTER 113 GELPUR FILTER SI 113 GELPUR SL

THE LEELA PALACES & RESORTS PVT. LTD. AGRA

Boss Water Systems Australia Reverse Osmosis System Model 021-4P-GM

Seawater Desalination Plant General Specification

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

Advanced water purifier system operation manual and setup guide

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters

NOTES P: 888-H2O-LOGIC ( ) F:

Membrane Bioreactor. Highest level of effluent standards

Dental Unit Water and Waterlines Chemical-Free Disinfection Handbook. Biofilm Removal & Prevention Water Disinfection Infection Control

Hollow Fiber and Tubular UF Pilot Testing Procedures & Case Studies

REVERSE OSMOSIS SYSTEM INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Cartwright Consulting Co.

KTDA SEMINAR WATER TREATMENT PRESENTATION. John Waema

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

General Specifications

CASE STUDIES AND LEARNINGS FROM TREATMENT INCIDENTS AT RECYCLED WATER PLANTS. Renwick Chan. Department of Health, Victoria

Cartwright Consulting Co.

NEW LOGIC RESEARCH. Case Study

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Welcome to the Pureit family World s largest selling purifier INSTRUCTION MANUAL. Classic - S X B 6 1 Classic - S Y B 6 1

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

Containerized Ultrafiltration (UF) Water Treatment Plant

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration

Transcription:

ULTRAFILTRATION UNIT DATA SHEET AUTOMATED MEMBRANE SOLUTION FOR SMALL SCALE WATER TREATMENT

1 DATA SHEET The - Series of ultrafiltration units provide stand alone capability requiring no additional operating equipment other than water pump, plumbing and tanks. Connections are plug-in requiring no hard-wiring of mains power. - Series provide pathogen-free water at low cost with minimal operator attendance. MULTI-MODULE AUTOMATED ULTRA FILTRATION UNITS P100MONO (20-25 kl/day) Single (1) module automated P200DUAL (40-50 kl/day) Dual (2) module automated P300TRI (60-70 kl/day) Tri (3) module automated P400QUAD (80-100 kl/day) Quad (4) module automated The - affords practical, small-scale potable water treatment using proven ultrafiltration () membrane technology. The system controller provides continuous, automatic water production via a TM ECO-FLUSH CLEAN CYCLE, with minimal operator input. The low-pressure hollow fibre () membrane filtration module is mounted inside moulded food grade polyethylene pressure housing. It is compact, tough, easy to transport and simple to install. The barrier filtration process provides primary disinfection by removing pathogens and particulates to supply safe drinking water from the majority of non saline surface and ground waters. Additional post filtration treatment including ultra violet (UV) or chlorine disinfection, or MIOX can be utilised if desired. Note: Design, data and dimensions are subject to modification without notice. TYPICAL APPLICATIONS Decentralised water treatment systems Community and rural small scale systems Remote mining and resource communities Point-of-entry filtration Emergency and temporary water supplies Hotels / restaurants / resorts Bottled water production RO (reverse osmosis) pre-treatment

- OPERATING DESCRIPTION Raw water flows into the auto ultrafiltration unit under minimal pressure. There is an option to utilise existing system pressure supply or an external feed pump. Feedwater passes through the porous walls of the hollow fibre membranes (outside to inside) and contaminates are retained on the membrane surface. The auto ultrafiltration unit is suitable for use in either pumped feed or gravity feed applications. Flow is regulated at a constant rate by a flexible orifice flow control valve supplied with the system. TM ECO-FLUSH Clean Cycle The key feature for successful operation of the auto ultrafiltration unit is the effectiveness of its patented backwash process, which uses low pressure aeration to maintain a clean membrane surface. The patented shell-scour protocol does not rely on conventional inside-outside reverse flush backwash operation. Neither air or water reverse flow is engaged during the backwash cycle. The low energy linear air pump provides the energy source for the intermittent purge of contaminants. SIMPLIFIED CLEANING CESS A simple automated low pressure aerated backwash sequence (patent pending) together with periodic chemical cleaning ensure high capacity and stable performance at low differential pressure, even with highly turbid feedwaters. Note: Design, data and dimensions are subject to modification without notice. LONG-TERM, HIGH PERFORMANCE FILTERS The membrane filtration modules use MEMCOR high permeability, low fouling PVDF hollow fibre membranes for optimum performance and long life. Our modules are simple in design and easy to install and maintain. Thousands of membrane plants globally rely on MEMCOR membrane modules for their water filtration requirements. 2 DATA SHEET 2 The controller initiates the backwash automatically, typically every 15, 30 to 60 minutes during filtration (as preset by operator). The system controller fully automates operation of the filtration and backwash cycles. Provision is made for a level switch input from a feed supply tank and a level switch input from a filtrate storage tank. These inputs may be used to pause the filtration operation as the liquid levels in the feed or filtrate storage systems change. This feature can be used to minimise operator attendance requirements during normal filtration service. The unit periodically requires a chemical clean or CIP (Clean In Place) cycle. This removes residual fouling that cannot be removed by the backwash process alone and helps to limit biological growth in the system. Sodium hypochlorite solution (household bleach or chlorine) is typically the chemical used for cleaning. Citric Acid is also used periodically (when iron is present in supply water). The system controller 200DUAL - 2 Module Unit

3 DATA SHEET TECHNICAL DATA SPECIFICATIONS Filtration of potable surface water, groundwater or seawater. Note: Not suitable for use with Typical Application water sources containing chemical or mineral contaminants such as heavy metals. Typical auto ultrafiltration unit production capacity treating clean surface water (per module housing) 1 Model Number -100-MONO Single Module Unit -200-DUAL -300-TRI -400-QUAD Membrane Module Details Materials of Construction: Module Housing Assmbly Valves Seals and Gaskets Pipe andffittings Filter Mode Operation Standard Flow Control Device Dual Module Unit Triple Module Unit Quad Module Unit Litres/min 18 36 54 Net kl/day 20 40 60 MEMCOR S10V membrane filtration module polyvinylidene fluoride (PVDF) hollow fibre ultrafiltration membrane with nominal pore size 0.04 μm Food grade polyethylene (PE) Various including PVC and PP EPDM typical Various including PE, ABS, Nylon and PVC Litres/day 20,000 40,000 60,000 US Gallons/day 5,200 10,400 15,654 72 80 80,000 20,872 Pressurised outside to inside filtration. Automatic standby on feed and filtrate storage levels via level switch inputs (where fitted). Automatic backwash at preset filtration intervals. Fixed flow rate flexible orifice flow control valve (FCV) (nominal instantaneous flow rate approx 18 litres per minute) OPERATING CRITERIA Typical Feed Inlet Pressure Range for Pumped Feed or High Head Gravity Feed (FCV fitted) Typical Feed Inlet Pressure Range for Low Head Gravity Feed (FCV not fitted) Maximum Housing Operating Pressure Feed Pre-screen Mesh Size Requirement 2 Maximum Recommeded Feed Turbidity 3 Filtered Water Turbidity Typical Log Reduction Value 10 m to 15 m (100-150 kpa) to 18 litres per minute per module housing. 20 m (200 kpa) maximum shut-off head 2 m (minimum) to 10 m (maximum) at 18 litres per minute (flow control manually adjusted). 200 kpa 500 μm or finer 50 NTU (typically) < 0.1 NTU > 4 LRV (for particles 2 5 μm) Operating Feed Temperature Range > 0 to 35 C ( > 32 to 95 F) Temperature Range for Transportation and Storage Feed ph Range Allowable ph Range for Cleaning Backwash Aeration Air Blower > 0 to 35 C ( > 32 to 95 F) 6.0 to 9.0 ph Note: Exposure to chlorine or chloramines is not recommended in feeds below 6.5 ph. 2 10 ph typical Note: Occasional brief exposure during chlorine cleans to 10.5 ph is acceptable. Automatically initiated and controlled, using low pressure air scour and feed flush. Compact linear air pump: ALITA AL-150 standard series high capacity air pump, single-phase AC power supply with rated performance 170 180 L/minute at 20 kpa (0.2 bar, 2.9 psig), approximately 140-Watts power consumption. 1 Capacity based on standard size flow control valve (FCV), standard configuration settings and no cleaning cycle. Feed water quality will affect production capacity. 2 Unscreened or coarsely screened raw water may reduce membrane-operating life. 3 Capacity and backwashing/cleaning frequency will typically vary with feed turbidity.

TIME SINCE LAST CHEMICAL CLEAN Waste Water Volume per Backwash CHEMICAL CLEANING CYCLE Concentrate and volume required Typical target chlorine concentration CITRIC ACID CLEANING CYCLE Concentrate and volume required Typical target acid concentration Electricity Supply Required Nominal 30 litres (maximum 36 litres) every backwash cycle per module housing. Gravity drain waste outlet to be provided adjacent to unit. Typically household liquid bleach is used. For sodium hypochlorite 5 % (or 5.0 g/l) concentration, approximately 100 150 ml will be used. Note: Cleaning solution waste may require further treatment, such as neutralisation, prior to disposal. 300 to 500 mg/l / 300 to 500 ppm Typically about 300 grams of citric acid powder will be used. 2.0 to 2.2 ph (not less than 2.0 ph) 2 DATA SHEET 4 220 260 VAC, 50 or 60 Hz single phase and earth (full sine wave only from DC to AC inverters other inverter wave forms not suitable) 110 130 VAC, 60 Hz option also available INSTALLATION CRITERIA Piping Terminations Recommended minimum clearances (for operation and Maintenance Access) Recommended Installation Location 25 BSP - NS (typical) Front and both sides 1,000mm Installed under cover with protection from direct sunlight and rainfall. System Controller INLET Sv1 OUTLET Sv2 WASTE Sv3 AIR Sv4 SYSTEM CONTROLLER Sv5 RINSE AIR PUMP WATER PUMP Microprocessor controlled by memory functions with LCD graphic display. Push button function keys for operator input by menu selection. Sealed polycarbonate enclosure with sealed external terminal and electrical connections. Hours Mins Secs MODE OK YES NO PRESS TO PRESS TO PRESS TO PRESS TO CHANGE COMMENCE RESUME STOP / PAUSE FILTRATION CHEMICAL OPERATION OPERATION MODE CLEAN Backwash intervals Mode 1: Every 60 min. Mode 2: Every 30 min. CONFIRM CONFIRM CONFIRM Mode 3: Every 15 min. CHOICE CHOICE CHOICE Flashing light indicates CHEMICAL CLEAN required (every 150 accumulated hours) CHEMICAL CLEAN STEPS PRESS OK to commence and follow screen prompts as below: PRESS YES - to confirm you wish to proceed (or NO to exit). Press A for chlorine or Press B for Citric Acid (when selecting chemical type). PRESS OK when chemical solution has been added to chemical tank (see User Guide for amount of chemical to use). PRESS OK when chemical tank cap has been replaced and firmly tightend. The unit will now automatically complete the chemical clean process. This will take 4 hours for a chlorine clean or 12 hours for a citric acid clean. Once completed the unit will automatically return to filtration mode. A B Built in switched power supply powers electronics, LCD, discrete inputs and 24 VDC solenoid valve and relay outputs. Advanced controller protection for electronics provided plus replaceable fuse. 24 VDC powered discrete inputs provided for feed level switch and filtrate level switch. 24 VDC powered discrete outputs for auto ultrafiltration unit mounted solenoid valves. Outputs provided for feed pump call to run and aeration blower call to run at same voltage and frequency as power incomer. NOTES: When displayed on LCD screen: STBY - system is in standby mode CLN - system is in cleaning mode The shell is the outer casing of the water filter. See USER GUIDE for detailed operation and fault diagnostics. WEIGHT & DIMENSIONS UNIT Dimensions & Mass (Approximate) Model Number Height (cm) Depth (cm) Width (cm) Mass (kg-dry) Mass (kg-wet) 100MONO - Single Module 161 34 51 50 75 200DUAL - Dual Module 161 34 71 70 100 300TRI - Triple Module 161 34 91 90 135 400QUAD - Quad Module 161 34 111 110 170 SHIPPING Dimensions & Mass (Approximate Shrink Wrapped Carton) Model Number Height (cm) Depth (cm) Width (cm) Weight(kg) 100MONO - Single Module 63 38 165 57 200DUAL - Dual Module 83 38 165 78 300TRI - Triple Module 110 38 165 100 400QUAD - Quad Module 124 38 165 145

5 DATA SHEET TYPICAL REQUIREMENTS FOR AUTO ULTRAFILTRATION UNIT OPERATION The auto ultrafiltration unit forms the core component of a membrane filtration system. Ancillary equipment external to the unit is required to complete connections to the system. Requirements vary from site to site but typically the client or end user must supply the following: 1) A suitable operating location Plus assembly and set up of the auto ultrafiltration unit. 2) Raw water feed delivery system Gravity feed or feed pump system within the specified flow and pressure range (including any external power supply requirements plus call to run signal connection via the system controller, if necessary); Feed tank (where required) and feed storage level switch (where fitted, plus connection to system controller); Feed supply pipe or hose connections and valves; Feed strainers/pre screens; Any other feed pre treatment requirements (such as ph correction). 3) The filtrate storage or distribution system A filtrate storage tank and filtrate storage level switch (where fitted, plus connection to system controller); Filtrate outlet pipe or hose connections and valves; Filtrate disinfection system (for potable water); Any other filtrate post treatment requirements. 4) The waste disposal system Free venting of air out of the waste outlet/vent termination point, allowing free discharge of aeration air from the top of the module housing; A freely draining pipe, pit or channel that removes liquid waste, without returning it to the feed water source; Pipe or hose connections from waste outlets on the unit to the waste disposal system; A means of neutralising cleaning solution waste liquid. 5) Electrical installation Power connection to the system controller from a protected (with external circuit breaker or fuse) single-phase power supply and earth. This also supplies the aeration blower output and the feed pump output (where used); Protected single phase (typically) power connection through the designated system controller relay contact to operate the feed pump (where used); Protected single phase (typically) power connection through the designated system controller relay contact to operate the aeration blower; Installation and connection of the feed level switch (where used) to the system controller; Installation and connection of the filtrate level switch (where used) to the system controller. 6) An operator to monitor unit operation and to perform cleaning cycles when necessary Please refer to the standard auto ultrafiltration unit process and instrumentation diagram and the typical system controller process and instrumentation diagram for operating process requirements.

ULTRAFILTRATION SYSTEMS Designed & manufactured in Australia by: AquaSynergy Solutions Pty Ltd ABN: 32 134 373 676 5/23 Enterprise Ave, Tweed Heads South NSW 2486 Australia Telephone Tel: +61 7 55 233 888 Email info@aquasolutions.com.au Website www.aquasolutions.com.au The information provided in this literature contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of the contract. Registered International Patent c Copyright 2015 AquaSynergy Solutions Pty Ltd