Causes and Remediation of Corrosion Failure of Duplex Stainless Steel Equipment in a PVC Plant

Similar documents
Factors Influencing Materials Selection in Condensing Economizers

STRESS CORROSION CRACKING OF STAINLESS STEELS IN HIGH PRESSURE ALKALINE ELECTROLYSERS

SANDVIK 3RE60 TUBE AND PIPE, SEAMLESS

Corrosion Properties of Enhanced Duplex Steel UNS S32304

Forta SDX 2507 EN , ASTM UNS S32750

Ultra 6XN EN , ASTM UNS N08926

STAINLESS STEEL SELECTION FOR FLUE GAS DESULFURIZATION EQUIPMENT

SANDVIK 254 SMO TUBE AND PIPE, SEAMLESS

Sandvik SAF 2205 (Billets)

Forta SDX 100 EN , ASTM UNS S32760

Forta LDX 2101 EN , ASTM UNS S32101

Forta SDX 100 EN , ASTM UNS S32760

Overmatching Superalloy Consumable Inco-weld 686CPT Broadens its Applications to Include Welding Super Austenitic and Super Duplex Stainless Steels

Moda 430/4016 EN , ASTM TYPE 430 / UNS S43000

Sensitization & Corrosion Behaviour of Austenitic Stainless Steel 304 & 316

family of stainless steels can be divided into five (5) categories:

Ultra 654 SMO EN , ASTM UNS S32654

Ultra 904L EN , ASTM UNS N08904

ATI 2205 ATI Technical Data Sheet. Duplex Stainless Steel GENERAL PROPERTIES. (UNS S31803 and S32205)

Good welding practice Stainless Steels

Outokumpu 2507 UNS S32750

Results are presented in Table 1. The tube was fabricated from a Type 347 and no unusual conditions were noted.

SANDVIK SPRINGFLEX SF SPRING WIRE WIRE

Crack Initiation and Crack Propagation of Pre-corroded Ni-16Cr Alloy in 4.5%NaCl Aqueous Solution

SANDVIK SAF 2304 TUBE AND PIPE, SEAMLESS

Corrosion Resistance and Weldability a Challenge for Duplex Filler Metals

SANDVIK SPRINGFLEX STRIP STEEL

Nominal Composition. Weight %

North American Stainless

UR 2202 is a low nickel, low molybdenum stainless steel designed to match the corrosion resistance of 304L in most environments.

Sandvik SAF 2205 (Tube and pipe, seamless)

A Study on the Corrosion Characteristics of Welded Stainless Steels Used in the Fabrication of Brine Circulating Pumps

Stainless Steel & Stainless Steel Fasteners Chemical, Physical and Mechanical Properties

Sandvik 316 (Plate and sheet)

Industry news. Recent findings on pitting and crevice corrosion: comparing SAF 2707 HD

SANDVIK SPRINGFLEX STRIP STEEL

Stress Corrosion Cracking of a Vinyl Chloride Stripper Vessel

Effects of Surface Finishes on Corrosion Resistance of Welded Stainless Steels

Therma 310S/4845 EN , ASTM TYPE 310S / UNS S31008

Chemical characteristics The chemical composition is shown in Table 1. Outokumpu EN ASTM

Technical Data & Welding Guidelines for Ferralium 255SD50 Super Duplex Stainless Steel

Moda 410L/4003 EN , ASTM UNS S40977

Effect of Modified AA5356 Filler on Corrosion Behavior of AA6061 Alloy GTA Welds

SANDVIK 5R60 FOR WIRELINES WIRE

MMFX 2 (ASTM A 1035, GRADE 100) STEEL REBAR CORROSION PERFORMANCE TESTING IN ACCORDANCE WITH AASHTO MP 18M/MP MMFX Technologies Corporation

Don t Repeat Mistakes! An SWRO Plant Case Study

AN OVERVIEW ON SHIELDED METAL ARC WELDING (SMAW) OF STAINLESS STEEL (SS)

Forta FDX 27 ASTM FDX 27 / UNS S82031

GUIDE TO STAINLESS STEELS AND DESALINATION

GUIDE TO STAINLESS STEELS AND DESALINATION

CORRMET LIMITED, 189 St. Georges Terrace, Level 8, Unit 2, Perth, Western Australia 6000,

CHAPTER 7 STUDIES ON CORROSION RESISTANCE OF STAINLESS STEEL CLADDINGS

A CORROSION MANAGEMENT AND APPLICATIONS ENGINEERING MAGAZINE FROM OUTOKUMPU 3-4/2013. The two phased optimization of duplex stainless steel

NITRONIC 19D LEAN DUPLEX STAINLESS STEEL

Therma 314/4841 EN , ASTM TYPE 314

CHAPTER-4 EXPERIMENTAL DETAILS. 4.1 SELECTION OF MATERIAL FOR CC GTAW & PC GTAW OF 90/10 & 70/30 Cu-Ni ALLOY WELDS

WHAT IS THE ACTUAL COST OF YOUR COMMERCIAL WATER HEATER? LOOKING BEYOND EFFICIENCY INCREASING ROI THROUGH WATER HEATER MATERIAL SELECTION

Standard Test Methods for Detecting Detrimental Intermetallic Phase in Duplex Austenitic/Ferritic Stainless Steels 1

Technical Data. Technical Data CS2205

Duplex Stainless Steel

PAGE 1/6 ZAPP PRECISION WIRE INCOLOY ALLOY 27-7MO (UNS S31277)

SANDVIK NANOFLEX STRIP STEEL

UR 2304: A 23Cr free Mo duplex stainless steel with PREN 24. C Cr Ni Mo N Thermal conductivity (W.m - 1.K - 1 ) Resistivity

SANDVIK SAF 2507 TUBE AND PIPE, SEAMLESS

Hastelloy C-2000 (UNS N06200)

NITRONIC 19D LEAN DUPLEX STAINLESS STEEL. Excellent Stress Corrosion Cracking Resistance. Improved Welding Characteristics

ASTM Standards for Pipe & Fittings

SANDVIK 3R60 TUBE AND PIPE, SEAMLESS

SANICRO 30 TUBE AND PIPE, SEAMLESS

Annex to the Accreditation Certificate D-PL according to DIN EN ISO/IEC 17025:2005

ATI ATI 2205 Alloy (UNS S31803 and S32205) Duplex Stainless Steel. Technical Data Sheet

Supra 316plus EN , ASTM UNS S31655

Stainless Steel. Patrick Ho, P.Eng, Senior Engineer, Applied Materials

WELDING TECHNOLOGY AND WELDING INSPECTION

SANDVIK 3R65 TUBE AND PIPE, SEAMLESS

Duplex Stainless Steel

GLORIA STEEL LIMITED Web: Fax: (UNS S32205/S31803) EN duplex stainless steel

Nonmagnetic stainless steels Amagnit

High-performance age hardenable nickel alloys solve problems in sour oil & gas service

Therma 4828 EN

Characterization of Oxide Film Formed on Ck45 Steel by Plasma Electrolytic Oxidation Method

SANDVIK 3R12 FOR MEDICAL APPLICATIONS TUBE AND PIPE, SEAMLESS

Electrochemical Corrosion Behavior of Tubing Alloys in Simulated Space Shuttle Launch Pad Conditions

Guidelines for the Construction of Pressure Vessel Type Tanks Intended for the Transportation of Anhydrous Ammonia at Ambient Temperatures

The Effect of Shot Peening on The Pitting Corrosion Resistance of Ferralium 255-SD50 and Uranus 45N in Acidified Carnalite and Sylvanite Solutions

AL 29-4C AL 29-4C. Technical Data Sheet. Stainless Steel: Superferritic INTRODUCTION (UNS S44735)

IPC TECHNICAL PAPER SERIES NUMBER 74 LOCALIZED CORROSION OF STAINLESS STEELS IN PAPER MACHINE WHITE WATER DAVID F. BOWERS FEBRUARY, 1979

Prevention Strategies Design and Coatings

Nonmagnetic stainless steels Magnadur

Density, lb/in g/cm Table 3 - Thermal and Electrical Properties

Duplex stainless steels for chemical tankers

CHROMESHIELD 22 STAINLESS STEEL

Influence of rapid cooling rates for HIP on mechanical and corrosion properties of UNS S32205

316/316L STAINLESS STEEL

C Cr Ni Mn Mo N < 2 > Thermal conductivity (W m - 1 K - 1 ) Resistivity

Welding duplex stainless steel the ESAB way

EFFECT OF FILLER ELECTRODES ON MICROSTRUCTURE AND MECHANICAL PROPERTIES OF DISSIMILAR WELD SS 316L AND SDSS 2507

Stainless Steel St St Introduction

MICROSTRUCTURE AND WELDABILITY EVALUATION OF DISSIMAILAR METAL JOINT USING PASTE TECHNIQUE FOR BUTTERING LAYERS

Thermal conductivity (W.m - 1.K - 1 )

Transcription:

acom AVESTA SHEFFIELD CORROSION MANAGEMENT AND APPLICATION ENGINEERING 3-2000 Causes and Remediation of Corrosion Failure of Duplex Stainless Steel Equipment in a PVC Plant Dr. Michael Davies, CARIAD Consultants, and Gerhard Potgieter, Polifin Group Engineering An existing PVC plant was modernised by the installation of a VCM stripper and two spiral heat exchangers, all made of 2205 duplex stainless steel (S21803). The purpose was to increase production and reduce VCM content of the product. After only nine months of service all equipment items suffered corrosion. After corrosion testing it was decided to replace the heat exchangers, using 6Mo austenitic stainless steel, while the stripper was repaired by welding. INTRODUCTION During modifications to an existing polyvinyl chloride (PVC) plant new stripping equipment was installed to increase production and reduce residual vinyl chloride monomer (VCM) in the product. This equipment included two spiral heat exchangers and stripping columns fabricated from type 2205 duplex stainless steel (UNS S31803). The top cones of the columns were 316L (UNS S31603). The duplex stainless steel was selected on the basis of resistance to localized corrosion and followed designs adopted by other PVC producers. After only nine months operation an inspection revealed corrosion in all the equipment items. On each of the two production streams, A & B, there is a stripping column with an associated spiral heat exchanger. The operating conditions are: Temperatures: Stripping columns: 95 C in at top, 105 C out at bottom Spiral exchangers: 105 C hot side 50 C cold side Process fluid: PVC/VCM/steam Process conditions: ph 2.5 5 Chlorides >50 ppm Low oxygen levels, 4 ppm is worst case. (See Figure 1). 40 m 3 AUTOCLAVE PVC REACTION AND STRIPPING BLOW DOWN VESSEL STRIPPING COLUMN SLURRY STOCK TANK SLURRY STOCK TANK TO DRYING SPIRAL HEAT EXCHANGER Figure 1. Schematic diagram of PVC stripping section showing stripper and spiral heat exchanger.

INSPECTION AND REPAIR OF COLUMNS In column A no cracking or other corrosion was found in the duplex column sections. There was some slight pitting on the 316L top cone. No remedial action was required. In column B many cracks and pits were observed in the top cone and in the shell sections and bottom cone. The cracking was usually associated with welds. Ultrasonic testing indicated cracks between 4 and 6 mm deep. This column was judged to be repairable. Since there was some danger in making the cracking worse as a result of weld repairs only those cracks considered dangerous to the operation of the column were repaired. The column was repaired using the following procedure: 1. Cracks were ground out to a smooth contour and dye penetrant tested to ensure their complete removal. 2. Ground out areas were thoroughly cleaned and visually inspected. 3. Areas to be repaired were preheated to 200 C and built up to original dimensions using GTAW (Gas Tungsten Arc Welding) followed by SMAW (Shielded Metal Arc Welding). Figure 2. Crack across weld in spiral heat exchanger. 4. Welded areas were ground flush and polished with a flapper wheel. 5. Repaired areas were shot peened with clean, new glass beads (800 microns), pickled using a proprietary paste and then passivated with nitric acid. 6. The column was pressure tested and put back into service. INSPECION OF SPIRAL HEAT EXCHANGERS Visual examination of the two exchangers detected 10 cracks on unit A and 5 cracks on unit B. Numerous pits were also observed on both units and the cracks were often initiated at corrosion pits, welds and locations where weld spatter was present on the surface. All cracking was on the hot side of the exchangers, none on the cold side. Crack length was up to 29 mm on unit A and 20 mm on B. Replicates taken of some of the cracks did not show branching. The spacer pins, which separate adjacent sheets of the exchanger, were also seen to be cracking and corroding. These pins were also 2205 and were attached by CDSW (Capacitor Discharge Stud Welding). It was concluded that neither of the exchangers could be repaired and both should be replaced. A typical crack across a weld is shown in Figure 2. MECHANISM OF CORROSION ATTACK Since the equipment was still in operation it was not possible to cut out sections to carry out exhaustive metallurgical examination which could determine the precise corrosion mechanisms operating. However, based on consideration of the process conditions, together with results of the inspection, it is probable that the mechanism was chloride stress corrosion cracking (SCC) combined with chloride pitting. The replicates taken of cracks were seen to be mainly straight rather than branched. This observation was suggested to be evidence that SCC was not the mechanism. However, in duplex alloys not all stress corrosion cracks are branched. Stress corrosion cracking in duplex alloys often is transgranular in the ferritic phase and intergranular in the austenite-austenite phase and austenite-ferrite grain boundaries. This process can result in brittle, transgranular cracks through the ferrite grains with complete dissolution of the austenite grains in between. The overall effect is a single, straight crack with fuzzy edges in regions of corrosion of the austenite, especially in replicates. The presence of SCC and pitting on the 2205 duplex alloy in these equipment items indicates that its corrosion resistance was marginal under the prevailing operating conditions. Similar cracking in PVC equipment has been reported previously where the association of cracking and welding was also reported and concluded to be due to the anodic polarization effect of the HAZ (Heat Affected Zone) by the weld due to the higher alloy content (1). The association of weld and cracking in this current case is probably due to rapid weld cooling because: a) Column B had SCC, column A did not. Column B was welded with FCAW (Flux-Cored Arc Welding) and column A with GTAW. Depending on the production rates and heat inputs it is likely that FCAW would produce more rapid cooling and thus unfavourably high ferrite contents. b) Since the spiral exchangers are constructed of thin plate it is again 2

likely that rapid cooling would occur locally during welding. c) The spacer pins on the heat exchangers which were also cracking/ corroding were attached using CDSW which uses low heat input and produces rapid cooling. d) Weld spatter on the hot side of the exchangers also promoted attack. Spot welds, tack welds and weld spatter are detrimental to the corrosion behaviour of duplex alloys because of their rapid cooling and higher ferrite content formed. INVESTIGATION OF OPTIONS FOR THE EXCHANGERS Both exchangers needed to be replaced. If the same material were to be used then the operating conditions would need to be altered to make the environment less aggressive to this duplex alloy. If the operating conditions were kept the same then a more resistant material would be required for the replacement exchangers. Both of these approaches were investigated. Changes in operating conditions Less aggressive operating conditions would require some combination of lower chloride content, temperatures and tensile stresses or increased oxygen content. The high chlorides are an essential component of the process so can not be reduced. Similarly, both operating temperature and pressures (thus tensile stress) are essentially fixed. The only possible factors that might be changed to reduce attack are ph or oxygen content. The ph would need to be consistently raised to at least 5 to enable 2205 to operate without significant corrosion. The methods available to increase ph are to change the catalyst, which is expensive, and/or lower oxygen level, which creates reaction problems and would increase corrosion. An added complication is that in some product grades high ph causes deposition in the strippers. Replacement spiral heat exchanger materials Since the plant could not operate continuously and consistently under conditions that would ensure no appreciable corrosion of 2205 it was decided to upgrade the materials of construction for the replacement heat exchangers. A number of candidate materials were considered, including SAF 2507, Inconel 625, Incoloy 825, Avesta Sheffield 254 SMO, Krupp VDM 1925 hmo, INCO alloy 25-6MO and Avesta Sheffield 654 SMO. Typical analyses of these materials are given in Table 1. It is probable that any of these alloys would be adequate but based on ease of fabrication and cost a super-austenitic stainless steel containing 6% molybdenum was selected as the primary candidate for further evaluation. Published information shows that 254 SMO is more resistant than SAF 2205 in standard pitting tests. An indication of the relative behaviour under SCC conditions is shown in Figure 3 (2). These published Table 2. Published data on pitting resistance (2). Alloy PRE CPT CPT IM NaCl 6% FeCl 3 316L 26 >15 <5 2205 36 >50 35 254 SMO 46 >90 75 PRE pitting resistance equivalent factor based on alloy composition CPT lowest temperature at which pitting occurs in these tests CPT in NaCl determined by polarization measurements CPT in FeCl 3 ASTM Standard G48A (3) TTF,h 600 400 200 316 2205 904L 254 SMO 0 0 20 40 60 80 100 Applied stress Rp 0.2 at 200 C x 100 Figure 3. Comparison of SCC behaviour of 2205 and 254 SMO (3). data from the NaCl drop evaporation test compare time to failure (TTF) in hours with applied stress levels for various alloys. These data are a bit misleading since the applied stress is related to the proof stress which is Table 1. Typical composition of alloys. Common Werkstoff UNS Cr Ni Mo Cu N C Other Name No. No. max. 316L 1.4404/35 S31603 17 12 2.7 0.03 2205 1.4462 S31803 22 5.5 3 0.17 0.03 2507 1.4410 S32750 25 7 4 0.27 0.03 I 625 2.4856 N06625 22 61 9 0.10 <5Fe,3.6Nb I 825 2.4858 N08825 21.5 42 3 2.3 0.05 0.9Ti 254 SMO 1.4547 S31254 20 18 6.2 0.7 0.2 0.02 1925 hmo 1.4529 N08926 20 25 6.2 0.8 0.2 0.02 I 25-6MO 1.4529 N08925 25 20 6.5 1.2 0.15 0.02 654 SMO 1.4652 S32654 24 22 7.3 0.5 0.5 0.01 3Mn 3

higher for 2205 than for the austenitics. Allowing for this strength factor would reverse the order of 2205 and 904L in this curve but 254 SMO would still have a longer TTF than the other two alloys. Since the corrosion behaviour of the 6% Mo super austenitic alloys commercially available are not necessarily the same it was decided to test the two principal candidates being considered, viz. 254 SMO and 1925 hmo. The replacement studs were to be I 625 welded on to the 6% Mo austenitic shell in the production of the replacement spiral exchangers. There was a possibility that this combination might reduce corrosion resistance due to precipitation of alloying elements, particularly molybdenum and chromium, and consequent depletion of these elements in the matrix. Such depletion can lead to a serious reduction in resistance to localized corrosion, i.e. pitting and crevice corrosion. This combination of stud and plate was tested with the alternate shell materials. 2 mm thick test plates were prepared from 254 SMO and 1925 hmo. I 625 studs, 5 mm diameter, were welded on to the plates using production stud welding equipment. All samples were then pickled and passivated. Corrosion testing There are a number of standard methods used to determine resistance to localized corrosion including immersion testing in various solutions and electrochemical techniques. Probably the most commonly used standard electrochemical method for this type of testing is ASTM G 61 (4). This standard cyclic potentiodynamic polarization method was used. However, since experience has shown that this standard test is often not severe enough to show differences in behaviour in modern, highly corrosion resistant alloys it was decided to include a more stringent test in addition to the ASTM G 61. This more severe test determines pitting potentials by polarizing samples at 80 C in a 1M NaCl solution, acidified to ph 2.2 with HCl, continuously oxygenated and stirred. Samples are first equilibrated for 1 hour with potential monitoring then scanned from 50 mv below the free corrosion potential at a scan rate of 0.17 mv/sec. The scan rate is reversed once a current density of 1000 µa/cm2 is reached. Potentials are measured against SCE (Saturated Calomel Electrode). The equipment used for all test work was an EG&G Model 273 Potentiostat/ Galvanostat. SOFTCORR Corrosion Software was used for the potential scans. Duplicate samples were tested using both methods for welded plates using each shell material, i.e. a total of eight tests. ASTM G 61-86 RESULTS In all four tests, i.e. for both shell materials, the samples were polarized well into the transpassive zone without exhibiting any signs of pitting. In the terms of this test all samples passed, i.e. were resistant to localized attack. THE ADVANCED ALLOY TEST RESULTS 254 SMO samples The pitting potentials measured were: Sample 1. 680 mv Sample 2. Transpassive without pitting. Pitted on reverse scan. 1925 hmo samples The pitting potentials measured were: Sample 1. 500 mv Sample 2. 493 mv Thus, there was good agreement between samples of the same material with the 254 SMO material showing some 200 mv improvement in pitting resistance over the 1925 hmo material in this test. Chromium Molybdenum Sample 3-254 SMO Sample 3-254 SMO Sample 4-254 SMO Sample 4-254 SMO Figure 4. Section through sample of 1925 hmo plate, weld and I 625 stud. Figure 5. Digital X-ray map of 254 SMO showing distribution of chromium and molybdenum in 2 samples. The plate material is at the top of each image. 4

Scanning electron microscopy (SEM) examination Sections were taken through studs and shell materials and mounted in epoxy resin. These sections were then prepared using standard metallographic techniques. All specimens were carbon coated and examined in a Phillips SEM fitted with Link Analyzer. Sections were examined for uniformity of weld and presence of defects or precipitates. The weld profiles were irregular in all four samples examined, see for example 1925 hmo in Figure 4. At higher magnification no gross precipitation was evident in the weld area. There was, however, some lack of bonding at the plate-weld interface in some areas. This weld profile variability and lack of bonding was not dependent on the shell material, (see Figure 4). X-ray analyses were carried out on stud, shell and weld material. Digital X-ray maps were also produced at low magnification to cover all areas of the sectioned joint (Figure 5). These analyses did not detect any areas of depletion or concentration of the key alloying elements in the weld or heat affected zone. No alloy-rich precipitated particles were detected (seefigure 5). DISCUSSION OF RESULTS FROM MATERIALS TESTING The electrochemical investigation has shown that the resistance of these alloys to localized corrosion by chlorides has not been diminished by the stud welding process, which is probably too fast to permit precipitation of alloy-rich particles. All samples passed the standard ASTM G 61 test and show acceptably high pitting potentials in the more severe test. The results obtained in this test compare well with the body of data generated previously for these alloys and with good service experience. There were, however, differences between the two shell materials as indicated by the advanced alloy test; the 254 SMO alloy showed higher pitting resistance than the 1925 hmo alloy. The reason for this difference was not investigated but is likely to be caused by the higher nickel content in Figure 6. Replacement spiral heat exchanger in 6% molybdenum austenitic stainless steel. the 1925 hmo and/or differences in processing the sheet during manufacture. The SEM examination showed no appreciable segregation of molybdenum or chromium. This correlates well with the pitting resistance behaviour. Lack of fusion at the edge of the stud welds was observed in some of the samples. This seemed to be related to the positioning of the stud over the plate prior to welding. Further evidence for this effect was found in the difference in weld reinforcement from one side of the stud to the other. Based on these results and prior experience it was recommended that the replacement exchangers should be fabricated from 254 SMO with I 625 spacer pins. In fact, both candidate alloys were used with 254 SMO in the hottest sections and 1925 hmo for the remainder. Quality assurance procedures were improved to eliminate the variability of adhesion and reinforcement found in some of the test pieces. Some changes were also made in the design of the spiral exchangers. The central inlet was modified changed to incorporate a patented design that gives better velocity distribution, eliminates dead spaces, produces less fouling and makes the exchangers easier to clean. One of the replacement exchangers is shown in Figure 6. CONCLUSIONS The duplex stainless steel 2205 is not suitable for this application in which it is exposed to hot solutions of chloride at low ph and oxygen content. The welding procedures and processes used for some of the fabrication exacerbated the corrosion problem. The corroded stripping column has been repaired under carefully controlled conditions and will be inspected regularly. The spiral heat exchangers could not be repaired so have been replaced using austenitic stainless steels containing 6% molybdenum. Corrosion tests showed that similar 6% Mo alloys do not give identical results. In order to further protect against corrosion in the columns and exchangers the process will be run at as high a ph as possible. In practical terms this means that this part of the plant will operate a ph of between 4 and 7 and preferably between 5 and 6. The oxygen content will be increased to around 35 ppm. 5

REFERENCES 1. M.J.G. Notten, Stainless Steel Europe, April, pp. 24-31 (1991) 2. Avesta AB Sweden, Avesta Information No. 9063, p. 4 3. ASTM Standard G48, (1997) 4. ASTM Standard G 61, (1986) ACKNOWLEDGEMENTS The authors wish to thank John Rodda and Chris Butcher of McMaster University for the electrochemical and metallographical examinations, respectively. This paper was originally presented at the 14th ICC Congress in Cape Town, September 1999, and it has also been published in revised form in Materials Performance, May 2000. 6

Although Avesta Sheffield has made every effort to ensure the accuracy of this publication, neither it nor any contributor can accept any legal responsibility whatsoever for errors or omissions or information found to be misleading or any opinions or advice given. 7

acom is distributed free of charge to persons actively involved in process industry development and other areas where stainless steels are important. acom appears four times a year, and we welcome applications from all interested parties for additions to our mailing list. Name: Please type or write legibly. Position: Company activity: Company: Mailing address: Postcode/City: Country: Please, add my name to your mailing list I have changed my address as shown above. My previous label is enclosed. acom 3.2000 All rights reserved. Comments and correspondence can be directed to Jan Olsson, Technical Editor, Avesta Sheffield AB, R&D, SE-774 80 Avesta, Sweden. Tel. +46 (0)226 812 48. Fax +46 (0)226 813 05. Avesta Sheffield AB Research and Development SE-774 80 Avesta, Sweden Tel. +46 (0)226 810 00 Fax +46 (0)226 813 05 www.avestasheffield.com ISSN 1101 0681. Teknisk information/centrumtryck Avesta 2000