Part Rod Design Maximum Iron. No. Size B C Load Pipe Size Per UL Approx. Wt./100. Part Rod Design Maximum Iron

Similar documents
Beam Clamps. B303-B309 - Beam Clamps. Fig. B321 - Series Beam Clamps. Size Range: 1 /4"-20 thru 5 /8"-11 rod

Part Rod Size Setscrew C T Design Load Approx. Wt./100 No. A Size in. (mm) in. (mm) Lbs. (kn) Lbs. (kg)

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Fire protection solutions

TOLCO Fire Protection Support Systems. Pipe Hangers Supports Seismic Bracing. UL Listed FM Approved for Fire Sprinkler Installations

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt

Fig. 1 - Standard Clevis Hanger

Fig Beam Clamp Retaining Strap (B-Line B3367)

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

1 1 4" FRAMING SYSTEM

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

Planning, Development & Facilities 349 Magnolia Avenue Glendale, California Tel: Fax: TRANSMITTAL

Seismic bracing products

SEISMIC SWAY BRACING

1470 Dale Court Austell, GA Phone: Fax:

ANVIL PIPE HANGERS AND SUPPORTS

PIPE HANGERS AND SUPPORTS PRICE LIST AND CONDENSED CATALOG

Pipe hangers & supports

Seismic Restraints. Cent-R-Rail Supplement* SYSTEMS THAT MAKE SENSE

PIPE HANGERS AND SUPPORTS PRICE LIST AND CONDENSED CATALOG

Electrical Metallic Tubing (EMT) Fittings

FS and FD Cast Hub Device Boxes UNILETS for use with Threaded Rigid Conduit and IMC. All device boxes have ridge top construction.

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

ANVIL PIPE HANGERS AND SUPPORTS PRICE LIST AND CONDENSED CATALOG

Pipe hangers & supports

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

Specifications Electrical Metallic Tubing (EMT)

Electrical Metallic Tubing (EMT) Fittings

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

CITY OF LOS ANGELES CALIFORNIA

DIVISION 15-MECHANICAL SECTION SUPPORTS AND ANCHORS PN PART 1 - GENERAL 1.01 SECTION INCLUDES. A. Pipe and equipment support systems.


SECTION HANGERS AND SUPPORTS FOR PLUMBING

TECHNICAL DATA OBSOLETE

COIN QR UPRIGHT FUSIBLE ELEMENT SPRINKLER VK901 (SPECIFIC APPLICATION) TECHNICAL DATA

STRUT METAL FRAMING SYSTEMS

B. American Society for Testing and Materials: 1. ASTM F708 - Standard Practice for Design and Installation of Rigid Pipe Hangers.

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

SECTION 16xxx NON-CONTINUOUS CABLE SUPPORTS FOR HIGH-SPEED TRANSMISSION CABLES (CATEGORY 5 AND HIGHER, AND OPTICAL FIBER CABLES)

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

MICROFAST COIN TM QUICK RESPONSE UPRIGHT SPRINKLER SIN VK900 (SPECIFIC APPLICATION) TECHNICAL DATA

Gas Station & C Store SECTION CWM Job No

COIN QUICK RESPONSE UPRIGHT SPRINKLER VK900 (SPECIFIC APPLICATION) TECHNICAL DATA

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SPRINKLER SYSTEM INSTALLATION GUIDELINES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION SEISMIC CONTROL OSHPD

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DOORS/HATCHES DOORS/HATCHES LET US KNOW YOUR REQUIREMENTS WATERTIGHT DOORS HATCHES SCUTTLES PORT LIGHTS PHONE FAX

Technical and Dimensional Data. Saf-T Vent SC

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

. SECTION HANGERS AND SUPPORTS

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Certificate of Compliance

B B B B3104 CT B3104CT CT B3104CT B3100C AS B422 Right Angle Clamp

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

A. Pipe Supports: ANSI B 31.1, Power Piping. B. Automatic Sprinkler Pipe Supports: Refer to Section

Suggested Materials and Tools:

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

Interior Hangers. Application

SECTION STANDPIPE AND HOSE SYSTEMS

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

TDC46M Carbon Steel Thermodynamic Steam Trap with Maintainable Seat

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT


Suspension System Data Center Ceiling Solutions

B52 CHANNEL & COMBINATIONS

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Project No

Conduit and Accessories. The Ultimate in Corrosion Protection! Nominal Wall Thickness. Nominal Wall Thickness. in. (mm)

Grape St. Denver, CO

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

PROJECT SUBMITTAL. Power-Stud TM. Wedge Expansion Anchor PROJECT SUBMITTAL CONTENTS APPROVALS AND LISTINGS

PRELUDE. 24 MAX TM Suspension System Data Centre Ceiling Solutions. Assembly and Installation Instructions

Suggested Materials and Tools:

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

TECHNICAL DATA COIN QUICK RESPONSE UPRIGHT SPRINKLER VK950 (SPECIFIC APPLICATION)

HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

DURA-BLOK Rooftop Supports


SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Bollard Chain Eye 3/8" (Powder Coated) Quick Link Connector 5/16" (Powder Coated) Optional Accessories:

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

1. Hangers and supports for electrical equipment and systems.

SRS-02 NEW SEISMIC RESTRAINTS. Multi-Directional Bracing For Electrical Conduit, Cable Tray And Mechanical Piping Systems SYSTEMS THAT MAKE SENSE

Superstrut. Metal Framing. Pipe Straps, Pipe Clamps and Hangers

STRUCTURAL STEEL FRAMING

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping inside the building.

Water & Industrial Products Catalog

SECTION NON-PENETRATING PORTABLE ROOFTOP SUPPORTS AND WALKWAYS. For best results, display hidden notes to specifier.

Transcription:

eam lamps 351L - Steel -lamp With Locknut (TOLO ig. 64) Size Range: 3 /8"-16 thru 7 /8"-9 rod Material: Steel unction: or attachment to I-beams, channels, and wide flange beams where the thickness does not exceed 3 /4" (19.0mm). Hardened set screw secures lamp to beam. pprovals: 351L ( 3 /8-16 - 3 /4-10), is Underwriters Laboratories Listed. onforms to ederal Specification WW-H-171 & --1192, Type 23 and Manufacturers Standardization Society NSI/MSS SP-69 & SP-58, Type 23. inish: Plain. ontact -Line for alternative finishes and materials. Note: When retaining strap is required, order 3362 thru 3365 separately. See page 29. Order y: Part number and finish Part Rod esign Maximum Iron No. Size Load Pipe Size Per UL pprox. Wt./100 in. (mm) in. (mm) in. (mm) Lbs. (kn) in. (mm) Lbs. (kg) 351L- 3 /8 3 /8"-16 2 3 /8" (60.3) 2 3 /8" (60.3) 3 /4" (19.0) 300 (0.89) 4" (100) 41 (18.6) 351L- 1 /2 1 /2"-13 2 3 /8" (60.3) 2 3 /8" (60.3) 3 /4" (19.0) 380 (1.69) 6" (150) 41 (18.6) 351L- 5 /8 5 /8"-11 2 3 /8" (60.3) 2 1 /4" (57.1) 3 /4" (19.0) 550 (2.44) 6" (150) 60 (27.2) 351L- 3 /4 3 /4"-10 2 3 /8" (60.3) 2 1 /4" (57.1) 3 /4" (19.0) 630 (2.80) 6" (150) 71 (32.2) 351L- 7 /8 7 /8"-9 3" (76.2) 3 1 /4" (82.5) 1" (25.4) 1200 (5.34) -- -- 184 (83.4) eam lamps 3036L - Malleable Iron -lamp With Locknut Size Range: 3 /8"-16 thru 3 /4"-10 rod Material: Malleable Iron unction: esigned for attaching a hanger rod to the flange of a beam. pprovals: 3036L is Underwriters Laboratories Listed. omplies with ederal Specification WW-H-171 & --1192 Type 23 and Manufacturers Standardization Society NSI/MSS SP-69 & SP-58 Type 23. inish: Plain or lectro-galvanized Order y: Part number and finish. When retaining strap is required, order 3362 thru 3365 separately. See page 29. 3/4" (19.0) Part Rod esign Maximum Iron No. Size Load Pipe Size Per UL pprox. Wt./100 in. (mm) in. (mm) Lbs. (kn) in. (mm) Lbs. (kg) 3036L- 3 /8 3 /8"-16 1 3 /4" (44.4) 1 3 /4" (44.4) 300 (0.89) 4" (100) 41 (18.6) 3036L- 1 /2 1 /2"-13 1 3 /4" (44.4) 1 3 /4" (44.4) 380 (1.69) 5" (125) 41 (18.6) 3036L- 5 /8 5 /8"-11 2" (50.8) 1 7 /8" (47.6) 530 (2.36) 6" (150) 60 (27.2) 3036L- 3 /4 3 /4"-10 2" (50.8) 2" (50.8) 530 (2.36) 6" (150) 71 (32.2) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 28

eam lamps 3362, 3363, 3364, 3365 - Retaining Strap Size Range: 6 (152.4mm) to 12 (304.8mm) lengths Material: Steel (Stainless Steel available) inish: Pre-Galvanized unction: esigned for use with 351L and 3036L -lamps. Order y: Part number, length 'L', (add 1" (25.4) minimum to flange width), and finish. Note: Requires field forming on beam. lange Width Length L in. (mm) in. (mm) 3-5 (76-127) 6 (152.4) 5-7 (127-178) 8 (203.2) 7-9 (178-228) 10 (254.0) 9-11 (228-279) 12 (304.8) 3/4" (19.0) L Material Thickness 12 Gauge (2.7) pprox. Wt./100 for Length 'L' of Part or Use With 6" (152.4) 8" (203.2) 10" (254.0) 12" (304.8) No. in. (mm) in. (mm) Lbs. (kg) Lbs. (kg) Lbs. (kg) Lbs. (kg) 3362-L 351L- 3 /8 & 1 /2 1 1 /4" (31.7) 7 /16" (11.1) 27 (12.2) 35 (15.9) 44 (19.9) 52 (23.6) eam lamps 3363-L 351L- 5 /8 & 3 /4, 1 1 /4" (31.7) 5 /8" (15.9) 26 (11.8) 35 (15.9) 43 (19.5) 52 (23.6) 3036L- 3 /8 & 1 /2 3364-L 3036L- 5 /8 & 3 /4 1 1 /4" (31.7) 11 /16" (17.4) 26 (11.8) 35 (15.9) 43 (19.5) 52 (23.6) 3365-L 351L- 7 /8 1 1 /2" (38.1) 3 /4" (19.0) 32 (14.5) 42 (19.0) 52 (23.6) 62 (28.1) 3037 - Z-Purlin Malleable -lamp Material: Malleable Iron unction: esigned for attaching a 3 /8"-16 hanger rod to the bottom flange of a Z-purlin. pprovals: Underwriters Laboratories Listed for up to 4 (100mm) pipe. onforms to ederal Specification WW-H-171 & --1192, Type 23 and Manufacturers Standardization Society NSI/MSS SP-69 & SP-58, Type 23. inish: Plain or lectro-galvanized Order y: Part number and finish. Weight: pprox. Wt./100 90 Lbs. (40.8kg) esign Load: 400 Lbs. (1.78kN) 3" (76.2) Throat Opening 31/32" (24.6) ottom Threads 3/8"-16 3 13 /32" (86.5) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 29

eam lamps 3031-3 /8 - Light uty Malleable -lamp Material: Malleable Iron unction: esigned for attaching a 3 /8"-16 hanger rod to the top or bottom flange of a beam or bar joist when setscrew is in the down position as shown. pprovals: Underwriters Laboratories Listed for up to 4 pipe. onforms to ederal Specification WW-H-171 & --1192, Type 19 and Manufacturers Standardization Society NSI/MSS SP-69 & SP-58, Type 19. inish: Plain or lectro-galvanized Order y: Part number and finish. When retaining strap is required, order ig. 69 separately. See Page 37. Weight: pprox. Wt./100 25 Lbs. (11.3kg) esign Load: 350 Lbs. (1.55kN) 1 1 /2" (38.1) 3/4" (19.0) 1 7 /8" (47.6) Throat Opening 11/16" (17.5) 3033 - Wide Jaw Reversible -lamp (TOLO ig. 68) Size Range: 3 /8"-16 thru 3 /4"-10 rod Material: ast Malleable Steel with hardened cup point set screw and jam nut unction: or attachment to structural shapes requiring wider throat especially under roof with bar joist construction. This clamp may be used with the set screw in the up or down position. pprovals: Underwriters Laboratories Listed (culus) and actory Mutual ngineering pproved (M). onforms to ederal Specification WW-H-171 Type 19 & --1192, Type 19 & 23 and Manufacturers Standardization Society NSI/MSS SP-69 & SP-58, Type 19 & 23. inish: Plain. ontact -Line for alternative finishes and materials. Order y: Part number, rod size and finish Note: o not over tighten set screw. Throat Opening 1 1 /4" (31.7) for 3033-3 /8 & 1 /2 1 5 /16" (33.3) for 3033-5 /8 & 3 /4 eam lamps Top lange ttachment pplications ottom lange ttachment pplications Part Rod esign Load with Setscrew Maximum Iron pprox. No. Size Up own Pipe Size Per UL Wt./100 in. (mm) in. (mm) in. (mm) Lbs. (kn) Lbs. (kn) in. (mm) Lbs. (kg) 3033-3 /8 3 /8"-16 2 1 /4" (57.1) 2" (50.8) 1 1 /8" (28.6) 610 (2.71) 610 (2.71) 4" (100) 54 (24.5) 3033-1 /2 1 /2"-13 2 5 /16" (58.7) 2 3 /16" (55.6) 1 1 /4" (31.7) 750 (3.33) 1130 (5.02) 8" (200) 51 (23.1) 3033-5 /8 5 /8"-11 2 5 /8" (66.7) 2 1 /2" (63.5) 1 3 /8" (34.9) 750 (3.33) 1130 (5.02) 8" (200) 70 (31.7) 3033-3 /4 3 /4"-10 2 11 /16" (68.3) 2 1 /2" (63.5) 1 7 /16" (36.5) 750 (3.33) 1130 (5.02) 10" (250) 98 (44.4) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 30

eam lamps 3034 - -lamp Size Range: 3 /8"-16 thru 3 /4"-10 rod Material: ast Malleable Steel with hardened cup point set screw and jam nut unction: Recommended for hanging from steel beam where flange thickness does not exceed 3 /4" (19.0mm). eatures: May be used on top or bottom flange of the beam. eveled lip allows hanging from top flange where clearance is limited. may be installed with the set screw in the up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. The rear window design permits inspection of thread engagement. pprovals: Underwriters Laboratories Listed and actory Mutual ngineering pproved for 3 /8-16 and 1 /2-13 rod sizes. onforms to ederal Specification WW-H-171 & --1192, Type 19 & 23 and Manufacturers Standardization Society NSI/MSS SP-69 & SP-58, Type 19 & 23. 3 /8"-16 is (culus) Listed to support up to 4" (100mm) pipe with the set screw in the down position, up to 3" (75mm) pipe with the set screw in the up position. 1 /2"-13 is (culus) Listed to support up to 8" (200mm) pipe with the set screw in the down position, up to 6" (150mm) pipe with the set screw in the up position. inish: Plain. ontact -Line for alternative finishes and materials. Order y: Part number and finish 3034-3 /8" and 3034-1 /2" sizes ttach only as shown. eam lamps Throat Opening 3/4" (19.0) Top lange ttachment pplications 3034-5 /8" and 3034-3 /4" sizes ttach only as shown. Throat Opening 3/4" (19.0) ottom lange ttachment pplications Part Rod esign Load with Setscrew Maximum Iron pprox. No. Size Up own Pipe Size Per UL Wt./100 in. (mm) in. (mm) in. (mm) Lbs. (kn) Lbs. (kn) in. (mm) Lbs. (kg) 3034-3 /8 3 /8"-16 1 5 /8" (41.3) 2" (50.8) 7 /8" (19.0) 610 (2.71) 610 (2.71) 4" (100) 30 (13.6) 3034-1 /2 1 /2"-13 1 13 /16" (46.0) 2 3 /16" (55.6) 1 3 /16" (30.2) 750 (3.33) 1130 (5.02) 8" (200) 47 (21.3) 3034-5 /8 5 /8"-11 1 3 /4" (44.5) 2 1 /8" (54.0) 1 1 /4" (31.7) 750 (3.33) 1130 (5.02) -- -- 58 (26.3) 3034-3 /4 3 /4"-10 2" (50.8) 2 1 /4" (57.2) 1 1 /4" (31.7) 750 (3.33) 1130 (5.02) -- -- 77 (35.0) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 31

ig. 68S - Reversible Malleable eam lamp 3 /4 (19.0mm) Throat Opening ig. 68W - Reversible Malleable eam lamp 1 1 /4 (31.7mm) Throat Opening (bottom of page) Size Range: 3 /8"-16 rod sizes thru 7 /8"-9 rod sizes eam lamps Material: ast Malleable Steel with hardened cup point set screw and jam nut unction: Recommended for hanging from steel beam where flange thickness does not exceed 3 /4 (19.0mm) on ig. 68S or 1 1 /4 (31.7mm) on ig.68w. eatures: May be used on top or bottom flange of beam. eveled lip allows hanging from top flange where clearance is limited. May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. The rear window design permits inspection of thread engagement. pprovals: actory Mutual ngineering pproved. Underwriters Laboratories Listed. onforms to ederal Specification WW-H-171, Type 23 and Manufacturers Standardization Society SP-58, Type 19. ig. 68S- 3 /8 is culus Listed to support up to 4 (100mm) pipe with the set screw in the down position and up to 3 (80mm) pipe with the set screw in the up position. ig. 68S- 1 /2 is culus Listed to support up to 8 (200mm) pipe with the set screw in the down position and up to 6 (150mm) pipe with the set screw in the up position. ig. 68W- 3 /8 is culus Listed to support up to 4 (100mm) pipe with the set screw in the down position and up to 4 (100mm) pipe with the set screw in the up position. ig. 68W- 1 /2 is culus Listed to support up to 6 (150mm) pipe with the set screw in the down position and up to 6 (150mm) pipe with the set screw in the up position. actory Mutual ngineering approved only with the set screw in the down position. (OSHP). or additional load spacing and placement information relating OSHP projects, please refer to the Seismic Restraint System Guidelines. inish: Plain. ontact -Line for lectro-galvanized or HG finishes. ig. 68W Order y: Part number and finish ig. 68S ig. 68S = epth of Throat eam lamps ig. 68W ig. 68S Max Rec. Load Max Rec. Load pprox. Part Rod Size Min. Set Screw Up Set Screw own Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Lbs. (kn) Lbs. (kn) Lbs. (kg) 68S- 3 /8 3 /8-16 1 9 /16 (39.7) 3 /4 (19.0) 1 1 /8 (28.6) 7 /16 (11.1) 7 /8 (22.2) 610 (2.71) 610 (2.71) 32 (14.5) 68S- 1 /2 1 /2-13 1 5 /8 (41.3) 3 /4 (19.0) 1 (25.4) 7 /16 (11.1) 1 1 /8 (28.6) 750 (3.33) 1130 (5.02) 54 (24.5) 68S- 5 /8 5 /8-11 1 9 /16 (39.7) 3 /4 (19.0) 1 (25.4) 9 /16 (14.3) 1 1 /8 (28.6) 750 (3.33) 1130 (5.02) 50 (22.7) 68S- 3 /4 3 /4-10 1 3 /4 (44.4) 3 /4 (19.0) 1 1 /8 (28.6) 9 /16 (14.3) 1 1 /4 (31.7) 750 (3.33) 1130 (5.02) 81 (36.7) 68S- 7 /8 7 /8-9 1 3 /4 (44.4) 3 /4 (19.0) 1 1 /8 (28.6) 9 /16 (14.3) 1 5 /16 (33.3) 750 (3.33) 1130 (5.02) 75 (34.0) ig. 68W Max Rec. Load Max Rec. Load pprox. Part Rod Size Min. Set Screw Up Set Screw own Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) Lbs. (kn) Lbs. (kn) Lbs. (kg) 68W- 3 /8 3 /8-16 1 9 /16 (39.7) 1 1 /4 (31.7) 1 1 /8 (28.6) 7 /16 (11.1) 7 /8 (22.2) 610 (2.71) 610 (2.71) 41 (18.6) 68W- 1 /2 1 /2-13 1 9 /16 (39.7) 1 1 /4 (31.7) 1 (25.4) 5 /8 (15.9) 1 1 /8 (28.6) 750 (3.33) 1130 (5.02) 66 (29.9) 68W- 5 /8 5 /8-11 1 1 /2 (38.1) 1 1 /4 (31.7) 1 (25.4) 9 /16 (14.3) 1 1 /8 (28.6) 750 (3.33) 1130 (5.02) 68 (30.8) 68W- 3 /4 3 /4-10 1 3 /4 (44.4) 1 1 /4 (31.7) 1 1 /8 (28.6) 3 /8 (19.5) 1 1 /4 (31.7) 750 (3.33) 1130 (5.02) 110 (49.9) 68W- 7 /8 7 /8-9 1 3 /4 (44.4) 1 1 /4 (31.7) 1 1 /8 (28.6) 9 /16 (14.3) 1 5 /16 (33.3) 750 (3.33) 1130 (5.02) 98 (44.4) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 32

eam lamps ig. 65 - Reversible Steel -Type eam lamp 3 /4 (19.0mm) Throat Opening ig. 65XT - Reversible Steel -Type eam lamp 3 /4 (19.0mm) Throat Opening (bottom of page) eam lamps Size Range: ig. 65-1 /2"-13 rod sizes, and 5 /8"-11 rod sizes ig. 65XT - 3 /8"-16 rod size (see below) Material: Steel with hardened cup point set screw and jam nut unction: Recommended for hanging from steel beam where flange thickness does not exceed 3 /4 (19.0mm). eatures: ll steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (eveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. pprovals: Underwriters Laboratories Listed in the US (UL) and anada (cul). xceeds requirements of the National ire Protection ssociation (NP), pamphlet 13, 3 /8"-16 rod will support 1 /2 (15mm) thru 4 (100mm) pipe 1 /2"-13 rod will support 1 /2 (15mm) thru 8 (200mm) pipe Included in the Seismic Restraints atalog approved by the State of alifornia Office of Statewide Health Planning and evelopment (OSHP). or additional load spacing and placement information relating OSHP projects, please refer to the Seismic Restraint System Guidelines. inish: Plain. ontact -Line for alternative finishes and materials. Order y: Part number and finish ig. 65 Patent #4,570,885 omponent of State of alifornia OSHP pproved Seismic Restraints System Part Rod Size No. in. (mm) in. (mm) in. (mm) in. (mm) 65-1 /2 1 /2-13 1 1 /2 (38.1) 3 /4 (19.0) 1 (25.4) 9 /16 (14.3) 65-5 /8 5 /8-11 1 1 /2 (38.1) 3 /4 (19.0) 1 (25.4) 9 /16 (14.3) Part Mac Rec. Load * pprox. Wt./100 No. in. (mm) in. (mm) in. (mm) 65-1 /2 1 1 /4 (31.7) 1130 (5.02) 55 (24.9) 65-5 /8 1 1 /4 (31.7) 1130 (5.02) 55 (24.9) * Maximum loads for clamp with set screw in up or down position. ig. 65XT- 3 /8 - eam lamp eature: xtruded holes allow for more thread engagement of threaded rod and set screw. Weight: pprox. Wt./100-28.0 Lbs. (12.7kg) esign Load: 730 Lbs (3.25kN) inish: Plain or lectro-galvanized Order y: Part number and finish pprovals: Underwriters Laboratories Listed and M pproved for uo to 4 (100mm) pipe. 3/4" (19.0) 1 3 /8" (34.9) 1 1 /8" (28.6) 1 9 /16" (39.7) 7/8" (22.2) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 33

eam lamps ig. 66 - Reversible Steel -Type eam lamp 1 1 /4 (31.7mm) Throat Opening Size Range: 3 /8"-16, 1 /2"-13 rod sizes, and 5 /8"-11 rod sizes Material: Steel with hardened cup point set screw and jam nut unction: Recommended for hanging from steel beam where flange thickness does not exceed 1 1 /4 (31.7mm). eatures: ll steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. (eveled lip allows hanging from top flange where clearance is limited.) May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. Open design permits inspection of thread engagement. pprovals: Underwriters Laboratories Listed in the US (UL) and anada (cul). xceeds requirements of the National ire Protection ssociation (NP), pamphlet 13, 3 /8"-16 rod will support 1 /2 (15mm) thru 4 (100mm) pipe 1 /2"-13 rod will support 1 /2 (15mm) thru 8 (200mm) pipe Included in the Seismic Restraints atalog approved by the State of alifornia Office of Statewide Health Planning and evelopment (OSHP). or additional load spacing and placement information relating OSHP projects, please refer to the Seismic Restraint System Guidelines. inish: Plain. ontact -Line for alternative finishes and materials. Order y: Part number and finish omponent of State of alifornia OSHP pproved Seismic Restraints System eam lamps Part Rod Size No. in. (mm) in. (mm) in. (mm) in. (mm) 66-3 /8 3 /8-16 1 3 /16" (30.2) 1 1 /4 (31.7) 1 (25.4) 7 /16 (11.1) 66-1 /2 1 /2-13 1 1 /2 (38.1) 1 1 /4 (31.7) 1 (25.4) 9 /16 (14.3) 66-5 /8 5 /8-11 1 1 /2 (38.1) 1 1 /4 (31.7) 1 (25.4) 9 /16 (14.3) Part Mac Rec. Load * pprox. Wt./100 No. in. (mm) in. (mm) in. (mm) 66-3 /8 1 (25.4) 610 (2.71) 28 (12.7) 66-1 /2 1 1 /4 (31.7) 1130 (5.02) 55 (24.9) 66-5 /8 1 1 /4 (31.7) 1130 (5.02) 55 (24.9) * Maximum loads for clamp with set screw in up or down position. ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 34

eam lamps ig. 67SS - Stainless Steel Reversible -Type eam lamp 3 /4 (19.0mm) Throat Opening ig. 68SS - Stainless Steel Reversible -Type eam lamp Wide Mouth Size Range: 3 /8"-16 and 1 /2"-13 rod sizes Material: Stainless Steel (Type 316 or 304) unction: Recommended for hanging from steel beams where flange thickness does not exceed 3 /4 (19.0mm) for ig. 67SS or 1 1 /4 (31.7mm) for ig. 68SS. eatures: ll steel construction eliminates structural deficiencies associated with casting type beam clamps. May be used on top or bottom flange of beam. May be installed with set screw in up or down position. Offset design permits unlimited rod adjustment by allowing the rod to be threaded completely through the clamp. pprovals: Underwriters Laboratories Listed in the US (UL) and anada (cul). onforms to Manufacturers Standardization Society NSI/MSS SP-69 & SP-58, Type 19. Meets or exceeds requirements of the National ire Protection ssociation (NP), pamphlet 13. 3 /8"-16 rod will support 1 /2 (15mm) thru 4 (100mm) pipe 1 /2"-13 rod will support 1 /2 (15mm) thru 8 (200mm) pipe Order y: Part number and stainless steel type. G eam lamps ig. 67SS Part Rod Size Pipe Size No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) 67SS- 3 /8 3 /8-16 1 /2" - 4 (15-100) 3 (76,2) 7 /8 (22.2) 1 (25.4) 1 5 /8 (41.3) 67SS- 1 /2 1 /2-13 5" - 8 (125-200) 3 (76,2) 7 /8 (22.2) 1 (25.4) 1 5 /8 (41.3) Part G Test Load pprox. Wt./100 No. in. (mm) in. (mm) in. (mm) in. (mm) 67SS- 3 /8 1 5 /8 (41.3) 1 1 /8 (28.6) 1500 (6.67) 84 (38.1) 67SS- 1 /2 1 5 /8 (41.3) 1 1 /8 (28.6) 4050 (18.01) 170 (77.1) ig. 68SS Part Rod Size Pipe Size No. in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) 68SS- 3 /8 3 /8-16 1 /2" - 4 (15-100) 2 1 /16 (52.4) 1 1 /8 (28.6) 3 /4 (19.0) 1 1 /4 (31.7) 68SS- 1 /2 1 /2-13 5" - 8 (125-200) 2 1 /4 (57.1) 1 1 /4 (31.7) 13 /16 (20.6) 1 1 /4 (31.7) Part Test Load pprox. Wt./100 No. in. (mm) in. (mm) in. (mm) 68SS- 3 /8 2 (50.8) 1500 (6.67) 84 (38.1) 68SS- 1 /2 2 1 /4 (57.1) 4050 (18.01) 170 (77.1) ll dimensions in charts and on drawings are in inches. imensions shown in parentheses are in millimeters unless otherwise specified. 35