High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

Similar documents
Lightning Speed superb acceleration rates with temperature shock test chambers

Maintaining Mobility. Test systems for lithium batteries

Environmental simulation chamber for cyclical temperature

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

KBWF 240 (E5.1) - Plant growth chamber with optimal climatic conditions

Anyvib Vibration Test Chambers

Solar Simulation Chambers Sun Event

The Stress Limit for your products. Temperature Shock Test Chamber Model TS 130. Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik

Solar Simulation Chambers SunEvent

Climate Test Chambers ClimeEvent

Global Partner for Environmental Test Chambers. VCE Emission Test Chambers. to Characterize Volatile Organic Compounds - VOC

Benchtop Temperature Test Chambers Lab Event

Temperature Shock Test Chambers Shock Event

TEMPERATURE CHAMBER (+5 C +180 C) TK-50 CK TK-105 CK TK-190 CK TK-340 CK TK-500 CK TK-1000 CK

Model BF 720 Incubators Avantgarde.Line with forced convection

Low Temperature Check. Automatic instrument for the determination for both TR TEST and BRITTLENESS POINT

Emission Test Chambers EmissionEvent VOC

Model KT 115 Cooling incubators with thermoelectric cooling

Model FDL 115 Safety drying chambers for limited quantities of solvent

GETINGE HS55 HOSPITAL STERILIZER. Always with you

LOTOS. Optical 3D measuring systems K O C O S A U T O M A T I O N [ ENG ]

GETINGE HS44 STERILIZERS FOR HIGH CAPACITY AT POINT OF USE. Always with you

CYTOPERM 2 CO 2 - AND CO 2

Model BF 260 Incubators Avantgarde.Line with forced convection

Model BF 56 Standard-Incubators with forced convection

CHL Laboratory refrigerators

Getinge HS55 Hospital sterilizer

Corrosion Chambers with Recirculating Air and Alternating Climate Control Salt Event SC/UKWT

FITOCLIMA WALK-IN STABILITY

FITOCLIMA WALK-IN STABILITY

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

Corrosion Alternating Test Chambers SC and SC/KWT

Redattore. Environmental Test Chambers Range of Production

Getinge HS44 sterilizer for high capacity at point of use

Corrosion Alternating Test Chambers Salt Event SC/KWT

T U R B O B L O W E R S

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

BPS X9 Maximum Precision at Record Speed

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

SECURE.GUARD Ultra low temperature freezer

Model KB 720 Cooling incubators with compressor technology

MIR COOLED INCUBATORS

Getinge HS66 Turbo Combi steam sterilizer for ordinary. Always with you

Low Temperature Testers

Model KB 23 Cooling incubators with compressor technology

Schleibinger Geräte Teubert u. Greim GmbH

testo 175-T1 testo 175-T2 1 channel temperature logger with internal sensor 2 channel temperature logger with internal sensor/external probe socket

400 C WHT 4/30 WHT 4/60 WHT 4/ C WHT 5/30 WHT 5/60 WHT 5/ C WHT 6/30 WHT 6/60 WHT

Pressure Transmitter STK136,STK136Q

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

Corrosion Alternating Test Chambers SaltEvent SC/KWT

Corrosion Alternating Test Chambers SaltEvent SC

Thermo Scientific Heraeus Cytoperm 2 CO 2 and CO 2 /O 2 Incubator

EN STERILINE 9.5. Class B and S sterilisation systems in compliance with international standards

Process assurance and monitoring in GMA welding Heinz Hackl, Wels

MATERIAL SPECIFICATION FOR UNINTERRUPTIBLE POWER SUPPLY SYSTEMS FOR LED TRAFFIC SIGNALS

INNOVATIVE LIFE-CYCLE CONCEPTS FOR MEDIUM-VOLTAGE SWITCHGEAR ON BROWN COAL SURFACE MINING DEVICES

Sterilization. Euronda Spa t (+39) m euronda.com

SPECIAL SPECIFICATION 8783 Border Safety Inspection Facility Transponder Reader System

6010 DIGITAL MOISTURE METER

HALT and HASS Test Equipment For Highly Accelerated Life Test and Stress Screen Applications. Weiss Umwelttechnik GmbH Simulationsanlagen Messtechnik

FITOCLIMA 600 & 1200 BIO

Perfect weighing of packaged goods... Bizerba Checkweigher CWF

SPECIAL SPECIFICATION 6683 Border Safety Inspection Facility Transponder Reader System

SPECIAL SPECIFICATION 8772 Border Safety Inspection Facility Transponder Reader System

D YNAMIC CHECKWEIGHING

Largo & Allegro. Air Compressors. Largo & Allegro

Continuous Gas Measurements Greater Measuring Accuracy Lower Maintenance Costs Reliable Measurement. From ENOTEC

All boilers with touch screens. Log Wood

Constant climate chambers KBF KBF P KBF LQC KMF

Fast. Easy to use. Secure traceability.

Universal cooler in individual design BASELINE BL 006 BL Customized refrigeration technology Made in Germany

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

Innovation in distillation. Pam v2. Automatic Distillation

BAUSCH + STRÖBEL. Technical Specification SP100/200 SP3060. Filling machine for bottles Page 1 of 6

B.O.D. INCUBATOR. Model no.: ACM I TECHNOLOGIES PVT. LTD.

Furnaces for Research and Laboratory. Testing Drying Ashing Tempering Preheating Sintering Firing Annealing

Best Selection for Your Business. Electronic Pricing Scale. User s Manual. (Model: TP-31)

v mw One turbine for one world vestas.com

Testing and Optimization

OXITEC Oxygen Analyser Systems. Maximum Efficiency and Supreme Quality for the World Market ENOTEC

Section II -Technical Specification

64C Amplification Block. Instruction Manual

Response Schedule 2 Decontamination: Multichamber Washer Disinfector of 12.

Rollair. Air Compressors ROLLAIR 150E AND ROLLAIR 150V-180V-240V

FITOCLIMA 600 & 1200 BIO

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications

Weigh it up! OCS Checkweighers for the Industrial Environment. Competence in dynamic weighing. A Wipotec Brand

Thermal processing equipment for laboratories

Totally Integrated Power NXAIR. Flexible in Application, Consistent in Safety. Air-Insulated Medium-Voltage Switchgear NXAIR.

30 years of experience one system: The comprehensive solution for your energy management needs. Your one-stop-shop.

MODEL NO. - ACM Q SEROLOGICAL WATER BATH

E9 Med. The strength of simplicity. Classification:

V MW. One turbine for one world. vestas.com

Laboklav. Type 55 to 195 Liter. Technical Datasheet. Dampfsterilisatoren Steam sterilizers

Thermal Shock Test Chambers TS Series

AUSTRACK -Accelerated Pavement Tester (APT)

Reliable, low-maintenance process heating

Thermoforming packaging machine R 145 with MULTIVAC Clean Design. Maximum process reliability and cleanroom suitability

Temperature Control. Whitepaper. for Chemical Research and Production. high precision thermoregulation. Temperature Control

Transcription:

High Speed... Rapid Temperature Change Rates with VTS & VCS Stress Screening Systems

Tested for absolute reliability... The testing of individual components ensures the reliability of your final product. 2 ESS

Safety reliability and much more... In critical situations we must fully rely on the safety systems functioning at all conditions. 3

photo ACOME Put reliability to the test... 4 Today, at the beginning of global communications we take fault-free operation for granted.

ESS... and don't leave anything to chance You can only successfully market a perfectly functioning product. 5

ESS...and why? Environmental Stress Screening (ESS) is a process which induces latent flaws in a product before it leaves the factory. Hence, ESS is always applied if the reliability of a product requires enhancing. The application of temperature shock cycling is the most effective method of creating premature failure in the production phase. Therefore it's possible to more rapidly detect weak points in design, material or in the production of electronic assemblies. F 5 K/min, 10 K/min and 15 K/min are the preferred change rates. For special applications we produce test chambers with temperature change rates up to 30 K/min. Temperature shock cycling for accelerated inspections are determined by test tailoring, with regard to both temperature extremes and the rapidity at which change occurs. Highly rapid temperature change rates create mechanical and thermal stress in specimens. 1 2 3 A t Life time graph of electronic components A = ESS moves these failures from field to factory F = Failures t = Time 1 = Infant mortality 2 = Operational lifetime 3 = Wear out phase T2 T Z ESS comprises the processes HALT (High Accelerated Life Testing) and HASS (High Accelerated Stress Screening) for the support of production development and quality assurance. Tu 1-30 K/min HALT is a process which generates an accelerated simulation of the product service life. Detection of weaknesses or errors in product design is extremely successful using this method. 6 T1 Changing temperature according IEC 60068-2-14, Test Nb T 1 = Temperature T u = Ambient temperature T 1 = Low temperature Z = N-cycles T 2 = High temperature t = Time t HASS, in contrast, is a process which induces latent flaws in a product, thus identifying premature failures before it leaves the factory.

1.0 0.8 A 10 20 30 40 50 Z 15 K/min 10 K/min 5 K/min 0.6 B 0.4 t=40 K t=20 K 0.2 C 50 100 150 t Effectiveness of thermal cycles and of high temperature storage for preconditioning of circuit boards A = Effectiveness, B = Thermal cycles, C = High temperature storage, Z = Cycles, t = Time t = Increased temperature to max. temperature for use Effectiveness of different environmental screening methods Temperature cycling Random vibration High temperature Electrical stress Thermal shock Sine vibration, fixed frequency Low temperature Sine vibration, sweep frequency Combined environmental Mechanical shock Humidity Acceleration Altitude A = Weighted Rank A 7

8

ESS... in practice Temperature and climatic test systems in the VTS & VCS series fill the gap between the wellproven VT/VC series and shock test systems. The test systems, which are equipped to offer greater power, are available in stylish designs. Various power modules heating, cooling and circulating air form the basis of tailor-made model ranges. Test chamber volumes from 190 to 1540 litres in a temperature range from -70 C to +180 C enable us to meet practically all customer requirements. Current climatic test standards are realised with the VCS series. Test systems in the VTS & VCS series are the true all-rounders among test systems. The speedy systems enable you to move into the overtaking lane with regard to the safety and reliability of your products. The integration of different power modules result in first-rate test systems to suit application specifications. Constant temperatures, constant climatic conditions, temperature changes and climates enhanced by rapid temperature changes confirm the "all inclusive" definition. The technology employed (which impresses through its sophisticated simplicity) leads to the achievement of results with the new VTS & VCS series which are extremely convincing as regards their value. Comprehensive services become comprehensive solutions. Touch panel for self-guiding, simple "touch and go" operation High-performance 32 bit control and monitoring system Specimen protection with independent measurement of temperature Automatically wetted, selfcleaning humidity sensor Service-friendly construction Optimum air flow 9

Function and technology in detail Due to direct temperature and climatic systems energy is transformed into power and not released. The high-gloss polished stainless steel test space is vapour-tight welded, with rounded edges and moulded shelf supports. It is resistant to corrosive attack and can be easily cleaned. Emissions from the system itself are minimized. Integrated illumination can be directly activated, and provides excellent light for the test chamber. It will, when necessary, be switched off automatically. The temperature systems provide high change rates in the range from -70 C to +180 C. High air flow rates ensure that temperature and humidity distribution is balanced. It goes without saying that it complies with the most common temperature and climatic test standards. The basis of the humidification and dehumidification system in climatic tests is the humidification bath. This technology ensures that water consumption is kept low, along with rapid reaction times and a high degree of long-term constancy. The measuring system required for humidity is considerably improved by an automatically wetted humidity sensor. This method of wetting leads to self-cleaning of the sensor and, as a result, an enormous increase in the service life of the psychrometric measuring principle. Other measuring systems are optionally available. 10

... and operation free of stress The control and communications system provides the highest level of operating convenience. A high-performance 32 bit control system provides the basis for the monitoring and control of the test systems. The removable touch panel has a graphics LCD-display with backlighting and with 1/4 VGA resolution. Process cycles, system states and other process diagrams can be represented as graphs thanks to self-explanatory pictograms and can be designed and operated intuitively in a manner so far not possible. Extensive test programs can be easily and reliably created, safeguarded and reactivated. A touch is sufficient and the desired functions are actuated. Climatic test programs compatible with current test standards are stored in our software. External control via the RS 232 interface is, of course, provided. The possibility to operate the system using a "laptop" is optionally available. The communication link to the chamber contains the basic functions emergency OFF, test specimen protection (min/max), serial and parallel interface and analogue and digital port for I/O signals. What would a highly developed, high-performance system be without software which is clear and easy to operate, enabling you to master the flow of information. It is called SIMPATI and determines the optional operating parameters for systems and test specimens. In addition to the well-known windows standards, the software can also be integrated into networks. Operation of test systems becomes simple and time-saving. System operating reliability is assured, thanks to the integrated monitoring routines. Evaluation and documenting of test cycles and the integration of special measuring data guarantees an improved standard. 11

Stress Screening Systems VTS & VCS 5 K/min Type VTS/VCS Test space volume litres Performance for temperature tests Temperature range C Temperature fluctuation temporal 1) K Deviation in space K Temparature gradient 1) K Temperature rate of Cooling K/min change acc. to IEC (1) Heating K/min Heat compensation at +20 C W at -20 C W Calibrated values Performance for climatic tests Temperature range C Temperature fluctuation temporal 1) K Deviation in space K Temperature gradient 1) K Humidity range % r. h. Humidity fluctuation % r. h. Dew point range C Heat compensation (2) W Calibrated values Test space dimensions Width mm Depth mm Height mm External dimensions Width mm Depth mm Height mm Noise level - 1 m distance from the front (3) db(a) Electrical connection Rated power kw Cooling water consumption (4) max. m 3 /h 4018-5 7018-5 4034-5 7034-5 4060-5 7060-5 4100-5 7100-5 4150-5 7150-5 190 190 335 335 600 600 990 990 1540 1540-40 -70-40 -70-40 -70-40 -70-40 -70 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 ±0.1 to ±0.5 ±0,5 to ±2.0 1 to 4 8.0 7.5 6.8 6.7 6.5 6.0 6.7 6.0 6.3 5.0 7.0 7.5 6.5 6.8 6.0 6.0 6.1 6.1 6.0 6.0 4000 3000 4000 3000 5000 5000 5000 5000 5000 5000 1500 3000 1500 3000 2000 5000 2000 5000 2000 5000 +23 C and +80 C only VCS +10 to +95 ±0.1 to ±0.3 ±0.5 to ±1.0 1 to 2 10 to 98 ±1 to ±3-3 to +94 400 400 400 400 500 500 500 500 500 500 +23 C / 50 % r. h. and +95 C / 50 % r. h. 580 580 580 580 800 800 1100 1100 1100 1100 450 450 765 765 800 800 950 950 1475 1475 750 750 750 750 950 950 950 950 950 950 870 870 870 870 1090 1090 1390 1390 1390 1390 1280 1280 1595 1595 1660 1660 1855 1855 2380 2380 1775 1775 1775 1775 1995 1995 1995 1995 1995 1995 61 64 61 64 66 69 72 73 72 73 3/N/PE AC, 400 V ±10 %, 50 Hz 8 10 8 10 11 16 23 26 23 26 1.9 1.4 1.9 1.4 2.7 2.1 3.5 3.0 3.5 3.0 Performance data refer to +25 C ambient temperature. (1) Temperature change rate according to IEC 60068-3-5, measured in the supply air stream. (2) At +25 C to +95 C, humidity up to max. 90 % r. h. is maintained. (3) At free field measurement according to DIN 45635, part 1, accuracy class 2. Standard equipping, perfect right down to the smallest detail... Touch control panel Microprocessor monitoring and control unit SIMCON/32 Digital I/O, potential-free 24 V, 4 freely available I/O Independent adjustable temperature limiter t min /t max Adjustable software temperature limiter min./max. Humidity input and display in % rel. humidity *) Centronics printer interface Serial interface RS 232 Potential-free contact for switching-off of test specimens Water-cooled refrigeration unit Aerosol-free humidification and dehumidification *) Psychrometric humidity measuring system *) Water supply tank for humidification water with level indication *) Automatic water replenishment with low water alarm *) European socket Calibration of 2 temperature values Calibration of 2 climate values*) 2 Entry ports 1 Shelf made of stainless steel *) only VCS 12

VTS & VCS 10 K/min VTS & VCS 15 K/min 4027-10 7027-10 4048-10 7048-10 4080-10 7080-10 4130-10 7130-10 4027-15 7027-15 4048-15 7048-15 4080-15 7080-15 4130-15 7130-15 270 270 480 480 800 800 1300 1300 270 270 480 480 800 800 1300 1300-40 -70-40 -70-40 -70-40 -70-40 -70-40 -70-40 -70-40 -70 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 +180 ±0.3 to ±1.0 ±0.3 to ±1.0 ±0.5 to ±2.0 ±0.5 to ±2.0 1 to 4 1 to 4 12.5 14.5 12.5 11.0 12.0 12.0 11.5 10.5 16.0 18.0 18.0 15.0 18.0 15.5 17.0 14.5 10.0 10.0 10.0 10.0 12.0 12.0 12.0 11.0 16.0 17.0 16.0 17.0 16.0 16.0 16.0 16.0 6000 6000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 2000 6000 3000 8000 3000 8000 3000 8000 3000 8000 3000 8000 3000 8000 3000 8000 + 23 C and +80 C + 23 C and +80 C only VCS only VCS +10 to +95 +10 bis +95 ±0.2 to ±0.5 ±0.2 to ±0.5 ±0.5 to ±1.0 ±0.5 to ±1.0 1 to 2 1 to 2 10 to 95 10 to 95 ±1 to ±3 ±1 to ±3-3 to +94-3 to +94 400 400 500 500 500 500 500 500 400 400 500 500 500 500 500 500 +23 C / 50 % r. h. and +95 C / 50 % r. h. +23 C / 50 % r. h. and +95 C / 50 % r. h. 580 580 800 800 1100 1100 1100 1100 580 580 800 800 1100 1100 1100 1100 620 620 650 650 800 800 1325 1325 620 620 650 650 800 800 1325 1325 750 750 920 920 920 920 920 920 750 750 920 920 920 920 920 920 870 870 1090 1090 1390 1390 1390 1390 870 870 1090 1090 1390 1390 1390 1390 1895 1895 2480 2480 2675 2675 3200 3200 1895 1895 2480 2480 2675 2675 3200 3200 1775 1775 2025 2025 2020 2020 2020 2020 1775 1775 2025 2025 2020 2020 2020 2020 68 73 72 73 73 73 73 73 70 73 72 73 73 73 73 73 3/N/PE AC, 400 V ±10 %, 50 Hz 3/N/PE AC, 400 V ±10 %, 50 Hz 8.0 14 16 17 28 34 28 34 12 16 20 24 35 44 35 44 2.4 3.8 3.5 4.2 4.2 5.5 4.2 5.5 3.5 4.2 6.1 6.3 7.0 8.0 7.0 8.0 (4) At cooling water temperature of +28 C and a temperature difference of 5 K, water temperature +12 C to max. +28 C. We reserve the right of changes in construction resulting from technical progress. The most important options... Some of the illustrated systems contain optional extras. Software Simpati Laptop Control unit Adjustable circulating air quantity Analogue transducer card I/O Measuring data acquisition system Temperature measuring on test specimen Interface converter RS 232 RS 422/485 or IEEE488 Interface RS 422/485 (Network card for test cabinet) Printers UV and/or IR-Irridation unit GN 2 - Inerting Compressed air dryer Water sprinkling device *) Demineralization unit *) Shock cooling with LN 2 Additional insert shelves Door with window Door with window and 2 handholes Notch Mobile design Special voltages Other options upon request *) only VCS 13

ESS... under stringent conditions Extremely rapid temperature cycling rates with 2 or 3 chamber method. Enhanced assignment conditions via combination of temperature cycles and vibration. 14

ESS... Special applications 15

Lightning Speed... Vibration and und mehr more... Environmental Simulation Beethovenstraße 34 72336 Balingen-Frommern Germany Telefon: +49 (0) 74 33 / 303-0 Telefax: +49 (0) 74 33 / 303-41 12 info@v-it.com www.v-it.com www.voetsch.info Nr. VIT-E 5/06A 6C 10.03 VN HD DIN EN ISO 9001 : 2000 www.dkd-temperatur-feuchte.de