Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output signals -wire: 4... 0 ma others on request Special characteristics turn-down :0 two chamber aluminium die cast case or stainless field housing internal or flush welded diaphragm HART -communication IS-version: Ex ia = intrinsically safe for gases and dusts Optional versions IS-version:Ex d = flameproof enclosure integrated display and operating module special materials as Hastelloy and Tantalum cooling element for media temperatures up to 300 C The process pressure transmitter XMP i has been especially designed for the process industry as well as food and pharmaceutical industry (version stainless steel field housing) and measures vacuum, gauge and absolute pressure ranges of gases, steam, fluids up to 00 bar. Different process connections such as threads and flanges with an internal or flush welded diaphragm are available and can be combined with a cooling element for media temperatures up to 300 C.The transmitter is as a standard equipped with HART -communication; the can choose between a two chamber aluminum die cast case or a stainless field housing. Preferred areas of use are Oil and gas industry / Chemical and petrochemical industry Food / Pharmaceutical industry Material and test certificates material mill test report 3. according EN 004 test report. to EN 004 74-0 BD SENSORS GmbH BD-Sensors-Straße Tel: +49 (0) 9 35 / 98-0 www.bdsensors.com D - 9599 Thierstein Fax: +49 (0) 9 35 / 98 - info@bdsensors.de
Pressure ranges Nominal pressure gauge / abs. 0.4 4 0 0 40 00 00 400 00 Overpressure 5 0 0 40 80 05 0 00 000 000 Burst pressure 3 7,5 5 5 50 0 0 40 000 50 50 On request we adjust the devices within the turn-down-possibility by software to the required pressure ranges. absolute pressure possible from bar Vacuum ranges Nominal pressure gauge -0.4 0.4 - - - 4-0 Overpressure 5 0 0 40 Burst pressure 3 7,5 5 5 50 Output signal / Supply Option Current consumption Performance Accuracy 3 Perfomance after turn-down -wire: 4... 0 ma IS-intrinsically safe version with HART -communication / V S =... 8 V DC IS version flameproof enclosure / VS = 3 8 V DC max. 5 ma ± 0. % FSO - turn-down :5: no change - turn-down > :5: The accuracy is calculated as follows 0. + 0.05 x (turn-down - 5) % FSO e.g. turn-down 9: 0. + 0.05 x (9-5) % FSO = 0. % FSO Permissible load R max = [(V S V S min) / 0.0 A] Ω load during HART communication: R min = 50 Ω Influence effects supply: 0.05 % FSO / 0 V permissible load: 0.05 % FSO / kω Long term stability ± 0. % FSO / year at reference conditions Response time 00 msec without consideration of electronic damping measuring rate 0/sec Adjustability electronic damping: 0 00 sec offset 0... 90 % FSO; turn-down of span up to :0 3 accuracy according to IEC 0770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal errors / Permissible temperatures Tolerance band 4, 5 Permissible temperatures Permissible temperature medium for cooling element 300 C 0. % FSO x turn-down (in compensated range -0 85 C) medium: -40... 5 C for filling fluid silicone oil -0... 5 C for filling fluid food compatible oil without display: environment: -40... 80 C storage: -40... 80 C with display: environment: -0... 70 C storage: -30... 80 C filling fluid silicone oil overpressure: -40 300 C low pressure: -40 50 C filling fluid food compatible oil overpressure: -0 50 C low pressure: -0 50 C 4 an optional cooling element can influence thermal effects for offset and span depending on installation position and filling conditions 5 for flange- and DRD-version: tolerance band offset ±. % FSO / tolerance band span ± 0. % FSO max. temperature of the medium for nominal pressure gauge > 0 bar: 50 C for 0 minutes with a max. environmental temperature of 50 C (without cooling element). Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 3 Mechanical stability Vibration 5 g RMS (5... 000 Hz) according to DIN EN 008-- Shock 00 g / msec according to DIN EN 008--7 Filling fluids silicone oil Options for process connections food compatible oil (with FDA approval) (Mobil SHC Cibus 3; Category Code: H; NSF Registration No.: 4500) Halocarbon and others on request Materials Pressure port stainless steel.4404 (3L) Housing aluminium die cast, powder-coated or stainless steel.4404 (3L) Cable gland brass, nickel plated Viewing glass laminated safety glass Seals (media wetted) thread: standard: FKM option: FFKM (min. permissible temperature from -5 C, possible for nominal pressure ranges P N 00 bar); others on request option: welded version for pressure ports according to EN 837 with P N between and 40 bar DRD and flange: none, not included in the scope of delivery Diaphragm Options for process connections stainless steel.4435 (3 L) Hastelloy C-7 (.489), Tantalum (possible from bar) on request Media wetted parts pressure port, seal, diaphragm pressure and level
Explosion protection Approval AX-XMP i IBExU 05 ATEX 0 X stainless steel field housing: zone 0 / 0: II G Ex ia IIC T4 Ga / II D Ex ia IIIC T85 C Da aluminium die cast case: zone / 0: II G Ex ia IIB T4 Gb / II D Ex ia IIIC T85 C Da Safety technical maximum values U i = 8 V, I i = 98 ma, P i = 80 mw, C i = 0 nf, L i = 0 µh, C GND = 7 nf Approval AX7-XMP i IBExU ATEX 045 X (flameproof enclosure) aluminium die cast case: zone : II G Ex d IIC T5 Gb Permissible temperatures for in zone 0: -40... 0 C with p atm 0.8 bar up to. bar environment zone or higher: -40... 70 C (intrinsically safe version); -0... 70 C (flameproof enclosure) Connecting cables (by factory) capacitance: signal line/shield also signal line/signal line: 0 pf/m inductance: signal line/shield also signal line/signal line: µh/m Miscellaneous Display (optionally) LC-display, visible range 3.5 x.5 mm; 5-digit 7-segment main display, digit height 8 mm, range of indication ±9999; 8-digit 4-segment additional display, digit height 5 mm; 5-segement bargraph; accuracy 0.% ± digit Ingress protection IP 7 Installation position any (standard calibration in a vertical position with the pressure port connection down; differing installation position have to be specified in the order) Weight min. 400 g (depending on housing and mechanical connection) Operational life > 00 x 0 pressure cycles CE-conformity EMC Directive: 004/08/EC Pressure Equipment Directive: 97/3/EC (module A) 7 7 This directive is only valid for devices with maximum permissible overpressure > 00 bar Wiring diagram P supply + VS I supply Pin configuration Electrical connections Supply + Supply Test Shield Housing designs 8 () aluminium die cast case aluminium die cast case: terminal clamps (clamp section:.5 mm ) IN+ IN- Test stainless steel field housing stainless steel field housing: terminal clamps (clamp section:.5 mm ) IN+ IN- - M0x,5 (for cable-ø 5 up to 4 mm) 74-0 M0x.5 (for cable-ø 5 up to 4 mm) Display (optional) * without display and operating module marked dimensions decrease by 9 mm (with aluminium case) for nominal pressure P N > 400 bar increases the length of devices by 39 mm 8 aluminium case is horizontally rotatable as standard www.bdsensors.com
pressure ports () SW7 G/" DIN 385 G/" flush (DIN 385) G/" EN 837 /" NPT bar P N 40 bar M0x.5 Process connections up to 40 bar () 9 Inch thread (DIN 385) DRD 9 Flange (DIN 50) G" flush ( 400 bar) Cooling element temperature range 300 C Membrane ( 5 bar) Flange (ANSI B.5) Clamp (DIN 37) Varivent (DN 40/50) P N 5 bar size ¾ DN5 DN3 DN50 A 4 3 3 45 B 5 50,5 50,5 4 4 8 74-0 0,5 flush diaphragm E Flush diaphragm E mounting flange is included in the delivery (already pre-assembled) HART is a registered trade mark of HART Communication Foundation; Hastelloy is a brand name of Haynes International Inc. Windows is a registered trade mark of Microsoft Corporation 74-0 size DN5 DN50 DN80 D 5 5 00 E 30 89 89 k 85 5 0 b 8 0 0 n 4 4 8 d 4 8 8 40 40 size "/50 lbs 3"/50 lbs D 5,4 90,5 E 8 89 g 9,9 7 k 0,7 5,4 b 9, 3,9 n 4 4 d 9, 9, 0 0 05 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials. pressure Tel: and level +49 (0) 9 35 / 98-0 www.bdsensors.com Fax: +49 (0) 9 35 / 98 - info@bdsensors.de XMP i_e_75
- - - - - - - - - - Pressure gauge 5 absolute 5 Input 0... 0.4 4 0 0 0 0... 0 0 0... 0 0 0... 4 4 0 0 0... 0 0 0 0 0 0 0 0... 40 4 0 0 0... 00 0 0 3 0... 00 0 0 3 0... 400 4 0 0 3 0... 00 0 0 3-0.4 0.4 S 4 0 0 - S 0 -... V 0-4 V 4 0-0 V 0 3 9 9 9 9 consult Design Aluminium die cast case with display A 0 without display A N Stainless steel field housing with display without display F V F N 9 9 consult Output Intrinsic safety 4 0 ma / -wire with HART -communication I Intrinsic safety Ex d 4 0 ma / -wire (flameproof enclosure) G with HART -communication 9 consult Accuracy 0. % Electrical connection terminal clamp alu housing terminal clamp field housing A K 0 8 8 0 9 9 9 consult Mechanical connection pressure connections G/" DIN 385 0 0 G/" with flush 3 welded diaphragm (DIN 385) Z 0 0 G/" EN 837 /" NPT 0 0 N 0 0 Process connections (up to 40 bar) G" with flush welded diaphragm (DIN 385) Z 3 Flange DN 5 / 40 (DIN 50) Flange DN 50 / 40 (DIN 50) Flange DN 80 / (DIN 50) F 0 F 3 F 4 Flansch DN " / 50 lbs (ANSI B.5) 4 F 3 Flansch DN 3" / 50 lbs (ANSI B.5) 4 F 3 3 DRD Ø 5 mm 5 Clamp DN 5 / " (DIN 37) / 3A Clamp DN 3 / /" (DIN 37) / 3A Clamp DN 50 / " (DIN 37) / 3A Clamp 3/4" (DIN 37) / 3A Varivent DN 40/50 / 3A D R D C C C 3 C 9 P 4 Diaphragm Stainless steel.4435 (3L) Hastelloy H Tantalum, 7 T consult Seals Inch thread: FKM FFKM 8 7 EN 837: without (welded version) 9 DRD, flange: without 0 Filling Fluids Silicone oil food compatible oil Halocarbon C consult 9 consult Special version standard 0 0 0 with cooling element up to 300 C 0 0 special compensation -40 +0 C 0 0 if setting range shall be different from nominal range please specify in your order absolute pressure possible from bar only possible in combination with aluminium die cast case 3 only possible for P N bar up to 40 bar 4 "/50 lbs and 3"/50 lbs possible for nominal pressure ranges P N 0 bar 5 mounting flange is included in the delivery (already pre-assembled) only possible with process connections 7 tantal diaphragm possible with nominal pressure ranges from bar 8 min. permissible temperature from -5 C, possible for nominal pressure ranges P N 00 bar 9 possible with pressure ranges between bar and 40 bar 0 option for version without display Ordering code XMP i HART is a registered trade mark of HART Communication Foundation; Hastelloy is a brand name of Haynes International Inc. 7.07.05 05 BD SENSORS GmbH The specifications given in this document represent the state of engineering at the time of publishing. We reserve the right to make modifications to the specifications and materials.