KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...
|
|
- Jerome Anthony
- 6 years ago
- Views:
Transcription
1 All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : l/h l/h water 5 - Nl/h Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection: O ¼" NPT thread ( valve) Material: stainless steel S1 O O Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA Phone: ; Fax: Sales@cabriggs.com - KOBOLD Messring GmbH Nordring D Hofheim/Ts. Head Office: +49(0) (0) info.de@kobold.com 1
2 Function The flows from bottom to top through the meter tube of the flow meter. The float is lifted until an annular gap between the measuring cone and the float is produced which corresponds to the flow. The forces acting on the float are in equilibrium. Technical Details Materials Measuring cone, float, armature: Sealing: stainless steel other materials on request (special on request) The height of the float resulting from the flow rate is transmitted by the permanent magnet in the float through the magnetic tracking system in a rotation to the pointer axis of the analog indicator unit. The variable-area flowmeter consists of a stainless steel device with an integrated conical stainless steel measuringtube and a vertically movable float. The valve for setting the flow rate is built-in (only -K/C). Application The meter is suitable for flow measurement of liquid or gaseous products in pipes. It shows the current flow rate in volume or mass per unit in time. Areas of Application Flow measurement of liquids and gases Dosing Can be used in the chemical industry or in medical or laboratory engineering Robust mechanical system with a low rate of wear The devices are available with additional electrical equipment for process monitoring and control. Design for horizontal and vertical connections available A variety of sealing materials Wall mounting possibility (-C) Flow Controller () High pressure application () Process connection: ¼" NPT (F), adapter for other connections available special connections on request Nominal pressure: PN 40 (-K, C) PN 63 (-S) al up to 420 bar (-S) Accuracy liquid/gas: ±3 % q G acc. VDE/VDI 3513 Process temperature: -40 C C ( switch/electronic) limit switch: NJ 1, 5-6, 5N -25 C C NJ 2-11 SN C -40 C C (c/w electronic -... E) Ambient temperature: -25 C C Weight: Protecion: 0.65 kg IP 65 (EN60529) Certificate and Approval Explosion protection: BVS 03 ATEX H/B 113 Pressure drop: [H 2 O/mbar] -S... -K/C... A 6 6 B C D 8 10 E 9 12 F G H I J 20 - K 28 - Reference condition: according to IEC 770, water at 20 C complete opened valve 2
3 Display: Electrical outputs: Limit s: Analogue output (- E): %- measuring range Ambient temperature: -25 C C 1 up to max. 2 inductive limit s, NAMUR (Pepperl & Fuchs NJ N); 8.2 V (R i ~1 KΩ) (NJ SN); 5 25 V DC ( wiring) ma, 2-wire, passive; V; burden max. 0 Ω version Ex (intrinsically safe) electrical connection via M12 plug Certification and Approvals Explosion protection: NJ1,5-6,5N PTB 00 ATEX 2048 X II 2G Ex ia IIC T6-T4 NJ 2-11SN PTB 00 ATEX 2049 X II 2G Ex ia IIC T6-T4 ZELM 03 ATEX 0128 X II 1D Ex iad 20 T... C -(E) II 2G Ex ib IIC T4 Gb, II 2D Ex ib IIIC T 135 C Db CE-Marking: Explosion Protection Directive 94/9/EC, PED 97/23/EG Electromagnetic compatibility for add-on electrical sensors: SIL: EMC-Directive 2004/108/EG EN :2006 SIL conformity acc. IEC-618-2:2000 and IEC-618-2:2010, declaration of conformity as separate document available Connection vertical -S... (Example: -SA P 30 A 00) l/h Nl/h SA SB SC SD SE SF SG SH SI SJ SK... A = % B = H 2 O C = E = MR- F = double s 4-20 ma 1/
4 Connection horizontal -K... (Example: -KA P 30 A 0 0) l/h Nl/h KA KB KC KD KE KF... 4, KG KH KI... U0 = ¼ NPT bottom O0 = ¼" NPT top A = % B = H 2 O C = E = MR- F = double acc. to s 4-20 ma Connection horizontal for wall mounting -C... (Example: -CA P 30 A 0 0) l/h Nl/h CA CB CC CD CE CF CG CH CI... U0 = ¼ NPT bottom O0 = ¼" NPT top A = % B = H 2 O C = E = MR-Scale F = double acc. to s 4-20 ma 4
5 Dimensions (mm) -K, C min. 92 max. 102 ¼" NPT D: 1000 kg/m³ T: 20 C V: 1m/Pas P: 40 bar über ¼" NPT S ¼"NPT D - D (1 : 1) D SW D: 1000kg/m³ T: 20 C V: 1 m/pas P: 40 bar über D 1/ Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA Phone: ; Fax: Sales@cabriggs.com - 5
TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max
Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless
More informationTSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max
Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless
More informationDiaphragm pressure gauge
Diaphragm pressure gauge with switch function, NS 00/60,Type series BE2 Features Diaphragm pressure gauge with switch function High quality case with bajonet ring NS 00/60 per EN 837-3 S, alternative safety
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up
More informationDMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm
Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output
More informationXMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor
Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output
More informationLMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request
More informationILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.
ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma
More informationFlow measurement of Liquids and Gases
Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.
More informationField case for temperature transmitter Model TIF11
Electrical temperature measurement Field case for temperature transmitter Model TIF11 WIKA data sheet TE 62.02 Applications Plant construction Process engineering General industrial applications Energy
More informationMagnetic float switch For vertical installation Model FLS for nuclear power plants
Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationLiquid level switch BW 17
KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level
More informationBypass Level Indicator / Functional description
Bypass Level Indicator / Functional description Functional description Bypass level indicators form an integral part of the pressure vessel. Via two process connections a standpipe ( bypass ) is mounted
More informationO O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers)
ypass Level Indicators ATEX or GL Approval measuring monitoring analysing NK -ATEX,-GL -03, -06, -07, -10 O O Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart O O Pressure:
More informationx act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.
Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output
More informationDiaphragm pressure gauge per EN 837-3,
Diaphragm pressure gauge per EN 837-3, chemical design, NS 100/160,Type series BA2 Features Diaphragm pressure gauge Nominal ranges -400 mbar to -1...24 bar, 0 25 mbar to 0 25 bar High quality case with
More informationPlastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases
Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or
More informationOPTIMASS 7400 Technical Datasheet
OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used
More informationMeasuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600
Bypass Level Indicators ATEX or GL Approval measuring monitoring analysing NBK -ATEX,-GL -03, -06, -07, -10 Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart Pressure: max.
More informationData Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.
Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ
More informationSITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview
Overview Design and operation The main components of the Tubux variable area meters are the glass variable-area flow tube with float, the fitting and the connection parts. The flow is displayed directly
More informationTURBINE METER RQ Series 1 and 2
1. IDENTIFICATION Manufacturer Bopp & Reuther Messtechnik Am Neuen Rheinhafen 4 67346 Speyer / Germany Phone: +49 6232 657-0 Fax: +49 6232 657-505 Product type Indirect volume meter Product name Turbine
More informationTTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma
Thermocouple Thermometers Ignition Protection Exd measuring monitoring analysing TTL-Exd T2 O O Measuring ranges: max. 1100 C OO NiCr-Ni or Fe-CuNi thermocouples OO Output: sensor or analogue 4-20 ma O
More informationLIQUID METER TYPE FMO
LIQUID METER TYPE FMO INNOVATORS IN FLOW TECHNOLOGY FLUX LIQUID METER TYPE FMO OVAL ROTOR DESIGN FLUX liquid meters type FMO are positive displacement flowmeters according to the oval rotor design. They
More informationOM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid
Screw-Type Volumetric Flow Meter for Viscous Media measuring monitoring analysing OM... Measuring ranges: 0.-0... 0-000 l/min liquid OMeasuring O accuracy: ± 0.% of span : 00 ± 0.% of span : 0 p max :
More informationOPTIMASS 7400 Technical Datasheet
OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used
More informationDON. Oval Wheel FIowmeter. for low and high viscous liquids. Measuring range: l/h und l/min
Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DON Measuring range: 0.5 36 l/h und 150 2500 l/min Viscosity range: 0 0 cp (higher on request) Accuracy: ±0,2 % 1% of
More informationKAL-K & KAL-A COMPACT THERMAL FLOW SENSOR
KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR Flow Pressure Level Temperature measurement monitoring control Revolutionary Microprocessor-Based Drift Stabilization NPT and 3-A Compliant Sanitary Fittings Non-Corrosive
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through
More informationSITRANS P measuring instruments for pressure
Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han
More informationVersaFlow Coriolis 200 Sensor for Mass Flow Specifications
VersaFlow Coriolis 200 Sensor for Mass Flow Specifications 34-VF-03-12 June 2011 The Solution for Bulk Mass Flow Measurement The VersaFlow Coriolis 200 has been developed to meet the demanding transfer
More informationDMH. Magnetic Inductive Flowmeter. for conductive fluids
Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C Connection:
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationTechnical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications
Technical Datasheet Pressure Switch Models: CS2 & CS4 Key Features Compact and rugged design. Stainless steel weatherproof enclosure IP66 / NEMA 4X Hermetically sealed SPDT or microswitch ATEX / IECEx
More informationDMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.
Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C O
More informationMAN-U. Differential Pressure Gauges. for high static pressures up to 200 bar. Housing: 100 mm, 150 mm
Differential Pressure Gauges for high static pressures up to 200 bar measuring monitoring analysing MAN-U Housing: 100 mm, 150 mm Material Housing: stainless steel Connection: stainless steel Movement:
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationA BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries
A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries 2 TSHY RESISTANCE THERMOMETER FOR THE FOOD AND BEVERAGE INDUSTRIES
More informationTOPAS PMG / PMH Hydraulic sensor Hot water
TOPAS PMG / PMH Hydraulic sensor Hot water Applications The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Features Insensitive to turbulences
More informationIntrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables
Data Sheet 907025 Page 1/12 Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables The hygrothermal transducers measure the relative air humidity and temperature
More informationMFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. : +200 C OScrew O thread: G ¼... G 4. t max. Rp 1...
Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN 40 OO t max : +200 C OScrew O tread: G ¼... G 4 OScrew O tread: Rp 1... Rp 2 OFlanges: O DN 50... DN 200 OSolder
More informationVersaFlow Coriolis 1000 Mass Flow Sensor Specifications
VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available
More informationTOPAS PMG Hydraulic sensor hot water
TOPAS PMG Hydraulic sensor hot water O f c c b a b d a d 5657244 5657264 565139.4 The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Applications
More informationRHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits
RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty
More informationWP-SDC COPPER CAN REGISTER WOLTMAN WATER METER
WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial
More informationRHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits
RHM60 Coriolis Mass Flow Meter with Uncompromising Performance Features Standard pressure ratings up to 490 bar (7107 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters
No. SS2-GTX00G-0100 (Rev.9) AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent
More informationWith uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.
průmyslová elektronika Capacitive level meters CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and
More informationProsonic Flow B 200. For reliable flow measurement of biogas without limitations
Prosonic Flow B 200 For reliable flow measurement of biogas without limitations Specially designed ultrasonic flowmeter for measuring biogas, landfill or digester gas One-of-a-kind direct measurement of
More informationPressure transducers DMU 02 Vario (flush)
Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load
More informationPresented By. NicolScales.com Contact Us
Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of
More informationVersaFlow Coriolis 6000 Sensor for Mass Flow Specifications
VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications 34-VF-03-27, July 2017 The Solution for extended temperature applications A high level of performance, together with a wide operating temperature
More informationIOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates
Data sheet DS/FPD510 EN IOMaster FPD510 Compact integral orifice flowmeter Low-cost measurement of small flowrates Compact flowmeter for small pipelines & flowrates available for pipe sizes 1 /2, 1 and
More informationProline Prosonic Flow B 200 For reliable biogas flow measurement without compromise
HAASE Energietechnik AG, Neumünster Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise Process monitoring and energy balancing made easy Innovative measurement industry-optimized
More informationAT9000 Advanced Transmitter Gauge Pressure Transmitters
No. SS2-GTX00G-0500 (Rev.3) AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent
More informationMechatronic pressure measurement. Applications. Special features. Description
Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data
More informationFLUIDISTOR GAS FLOWMETER GD 100 (EX)
FLUIDISTOR GAS FLOWMETER GD 100 (EX) for measuring of all technical and medical gases DN25 - DN400 Oscillating measuring principle, without moving parts Resistent to dirt, e.g. oil and rust residues in
More informationLarge selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm
Bi-metal Thermometers all Stainless Steel Construction measuring monitoring analysing TBE Fast response times Large selection of standard versions Special versions at customer request Nominal sizes: 100,
More informationdigitalyewflo Series Vortex Flowmeter Installation Manual
User s Manual digitalyewflo Series Vortex Flowmeter Installation Manual Manual Change No. 17-0024-E Please use the attachment sheets for the (2nd). No. Page / Addition/Correction Description Section 1
More informationsira IECEx Certificate of Conformity
IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:
More informationP430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information:
P430 Series Glass Tube Variable Area Flow Meter Parker P Series glass tube flowmeters deliver unsurpassed performance and value in a wide variety of gas and liquid applications. P430 Series flow meters
More information4-Beam-Turbidity Meter ITM-4
SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring
More information4-Beam-Turbidity Meter ITM-4
SENSORS FOR AND BIOPHARMA. Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase
More informationALTOFLUX IFS 4000/4005
KROHNE 03/2002 7.02351.22.00 GR ALTOFLUX IFS 4000/4005... result of more than 40 years experience with electromagnetic flowmeters Liner made of KROHNE Teflon -PFA or other fluorines Dimensionally stable,
More information8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.
SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional
More informationEE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationHazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb)
Spec-01168 Hazardous Location Enclosures Hazardous Location Enclosures and Accessories Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb) APPLICATION Hazloc cable glands provide strain relief,
More informationTRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY
Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationTurbine Meter. P e
Turbine Meter P 402.003e Turbine Flow Meters Table of Contents Applications of the Turbine Meter RQ Series Page 3 Type RQ for Liquids Page 4 RQ Turbine Meter with UST Universal Transmitter Page 7 RQ Turbine
More informationEE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationCATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.
CATALOG Variable Area Flowmeter EASYFLOW www.sedflowcontrol.com SMART IN FLOW CONTROL. Easyflow Applications Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment
More informationSentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications
GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available
More informationCAPACITIVE LEVEL METERS CLM 36
CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by
More informationThermometer in stainless steel with vertical stem in stainless steel
Ed.18.01 Design Thermometer in stainless steel with in stainless steel 1.4571 Design EN 13190 Case diameter Dim 63, 100 eller 160 mm Accuracy Class 1,0% acc.to DIN EN 13190 Type Case Glass 5500 = case
More informationVARIABLE AREA FLOWMETER EASYFLOW.
VARIABLE AREA FLOWMETER EASYFLOW www.sedflowcontrol.com EASYFLOW APPLICATIONS Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment Plant Reverse Osmosis System Water
More informationCLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories
CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid
More informationCoriolis Mass Flow Meter
Coriolis Mass Flow Meter P Series High Precision Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;
More informationVLM10 In-line Vortex Mass Flow Meter
VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process
More informationModel 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas
Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas Thermo Scientific insertion turbine flowmeters have provided highly accurate and repeatable flow measurements for large pipeline applications
More informationHLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features
HLX300ExHT The HLX300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone
More informationEletta Flow Monitor for use in explosive atmospheres
NEWThe V-Ex Eletta Flow Monitor for use in explosive atmospheres For some time there has been a demand from the market to offer explosion proof versions. An increasing number of customers and end users
More information4-Beam-Turbidity Meter ITM-4
1 Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Authorizations Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase separation
More informationSI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:
SI-02 Electromagnetic Flowmeter for General Applications Description: Features / Universally applicable / Separate or compact measuring transmitter / Variety of lining material / DN15 to DN2000 / DIN-
More informationVibranivo Mononivo. Series VN 4000 MN Series. Instruction manual
Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de
More informationAPT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)
Range and Sensor Limits Refer to Table 1 Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum
More informationTUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU
TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact
More informationVortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)
Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet
More informationRotating Vane Level Monitor
Rotating Vane Level Monitor measuring monitoring analysing Fixed shaft or cable shaft Bulk materials: 0.2 to 2.5 t/m 3 Max. particle sizes: 50 mm Temperature: max. 85 C Max. filling level: 5 m pmax: 0
More informationThermometer in stainless steel with capillary for mounting in thermowell or for direct mounting
Ed.17.02 Design Type Case diameter in stainless steel for mounting in thermowell or for direct mounting F73 Dim 100 mm or 160 mm Accuracy Class 1,0% DIN EN 13190 Case Glass Stainless steel with bayonet
More informationContact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications
Force Pressure Temperature Switch Contact thermometer Bimetal- or Gas actuated thermometer - Inductive contacts - Sliding contacts - Snap action contact - Class 1 acc. to DIN EN 13190 - Optional with liquid
More informationTuffy II Liquid Level Controls with Electric Switches
Tuffy II Liquid Level Controls with Electric Switches D E S C R I P T I O N The Tuffy II Liquid Level Switches are float-actuated devices designed for horizontal mounting in a tank or vessel through threaded
More informationMicro Motion LNG Series Meters
Product Data Sheet PS-002079, Rev B February 2018 Micro Motion LNG Series Meters Global industry standard for liquefied natural gas metering A complete, dedicated Coriolis meter solution for LNG dispensing
More informationLoad cell Pendeo Process and mounting kits
Load cell Pendeo Process and mounting kits Digital weighing technology for maximum transparency and precision The digital compression load cells in the Pendeo Process series are specially designed for
More informationVersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.
VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet 34-VF-03-12 October 2009 Specification The solution for bulk mass flow measurement The VersaFlow Coriolis 200 has been developed to meet
More informationU6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS
ORIFICE PLATE FLOW INDICATOR U6 SERIE - Mounting in all positions - Construction: cast iron or stainless steel - For pipes from ND 40 up to ND 300 mm - Scale amplification from 2 to 10 - Accuracy: ± 2.5
More informationModels A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership
Data sheet DS/6/6EN Rev. K Models 600 & 600 Purgemaster SNP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength stainless steel body the body is corrosion
More informationType Type 2000 Transducers. I/P & E/P Transducers
Type 2000 I/P & E/P Description Principle of Operation The Type 2000 I/P and E/P transducers utilize closed-loop pressure feedback-control for precision pressure output and minimized effects of temperature,
More information