KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

Size: px
Start display at page:

Download "KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h..."

Transcription

1 All Metal Variable Area Flowmeter for liquids and gases measuring monitoring analysing : l/h l/h water 5 - Nl/h Nl/h Accuracy: ±3 % of full p max : 420 bar; t max : 130 C OConnection: O ¼" NPT thread ( valve) Material: stainless steel S1 O O Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA Phone: ; Fax: Sales@cabriggs.com - KOBOLD Messring GmbH Nordring D Hofheim/Ts. Head Office: +49(0) (0) info.de@kobold.com 1

2 Function The flows from bottom to top through the meter tube of the flow meter. The float is lifted until an annular gap between the measuring cone and the float is produced which corresponds to the flow. The forces acting on the float are in equilibrium. Technical Details Materials Measuring cone, float, armature: Sealing: stainless steel other materials on request (special on request) The height of the float resulting from the flow rate is transmitted by the permanent magnet in the float through the magnetic tracking system in a rotation to the pointer axis of the analog indicator unit. The variable-area flowmeter consists of a stainless steel device with an integrated conical stainless steel measuringtube and a vertically movable float. The valve for setting the flow rate is built-in (only -K/C). Application The meter is suitable for flow measurement of liquid or gaseous products in pipes. It shows the current flow rate in volume or mass per unit in time. Areas of Application Flow measurement of liquids and gases Dosing Can be used in the chemical industry or in medical or laboratory engineering Robust mechanical system with a low rate of wear The devices are available with additional electrical equipment for process monitoring and control. Design for horizontal and vertical connections available A variety of sealing materials Wall mounting possibility (-C) Flow Controller () High pressure application () Process connection: ¼" NPT (F), adapter for other connections available special connections on request Nominal pressure: PN 40 (-K, C) PN 63 (-S) al up to 420 bar (-S) Accuracy liquid/gas: ±3 % q G acc. VDE/VDI 3513 Process temperature: -40 C C ( switch/electronic) limit switch: NJ 1, 5-6, 5N -25 C C NJ 2-11 SN C -40 C C (c/w electronic -... E) Ambient temperature: -25 C C Weight: Protecion: 0.65 kg IP 65 (EN60529) Certificate and Approval Explosion protection: BVS 03 ATEX H/B 113 Pressure drop: [H 2 O/mbar] -S... -K/C... A 6 6 B C D 8 10 E 9 12 F G H I J 20 - K 28 - Reference condition: according to IEC 770, water at 20 C complete opened valve 2

3 Display: Electrical outputs: Limit s: Analogue output (- E): %- measuring range Ambient temperature: -25 C C 1 up to max. 2 inductive limit s, NAMUR (Pepperl & Fuchs NJ N); 8.2 V (R i ~1 KΩ) (NJ SN); 5 25 V DC ( wiring) ma, 2-wire, passive; V; burden max. 0 Ω version Ex (intrinsically safe) electrical connection via M12 plug Certification and Approvals Explosion protection: NJ1,5-6,5N PTB 00 ATEX 2048 X II 2G Ex ia IIC T6-T4 NJ 2-11SN PTB 00 ATEX 2049 X II 2G Ex ia IIC T6-T4 ZELM 03 ATEX 0128 X II 1D Ex iad 20 T... C -(E) II 2G Ex ib IIC T4 Gb, II 2D Ex ib IIIC T 135 C Db CE-Marking: Explosion Protection Directive 94/9/EC, PED 97/23/EG Electromagnetic compatibility for add-on electrical sensors: SIL: EMC-Directive 2004/108/EG EN :2006 SIL conformity acc. IEC-618-2:2000 and IEC-618-2:2010, declaration of conformity as separate document available Connection vertical -S... (Example: -SA P 30 A 00) l/h Nl/h SA SB SC SD SE SF SG SH SI SJ SK... A = % B = H 2 O C = E = MR- F = double s 4-20 ma 1/

4 Connection horizontal -K... (Example: -KA P 30 A 0 0) l/h Nl/h KA KB KC KD KE KF... 4, KG KH KI... U0 = ¼ NPT bottom O0 = ¼" NPT top A = % B = H 2 O C = E = MR- F = double acc. to s 4-20 ma Connection horizontal for wall mounting -C... (Example: -CA P 30 A 0 0) l/h Nl/h CA CB CC CD CE CF CG CH CI... U0 = ¼ NPT bottom O0 = ¼" NPT top A = % B = H 2 O C = E = MR-Scale F = double acc. to s 4-20 ma 4

5 Dimensions (mm) -K, C min. 92 max. 102 ¼" NPT D: 1000 kg/m³ T: 20 C V: 1m/Pas P: 40 bar über ¼" NPT S ¼"NPT D - D (1 : 1) D SW D: 1000kg/m³ T: 20 C V: 1 m/pas P: 40 bar über D 1/ Order from: C A Briggs Company 622 Mary Street; Suite 101; Warminster, PA Phone: ; Fax: Sales@cabriggs.com - 5

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max Flap Flowmeter for liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max

TSK. Flap Flow Meter for Liquids. Range: m 3 /h Accuracy: ± 2.0 of reading p max Flap Flow Meter for Liquids measuring monitoring analysing TSK Range: 0.5-3.5 200-1500 m 3 /h Accuracy: ± 2.0 of reading p max : PN 40, t max: -40 +300 C Connection: wafer flange DN 25 500 Material: stainless

More information

Diaphragm pressure gauge

Diaphragm pressure gauge Diaphragm pressure gauge with switch function, NS 00/60,Type series BE2 Features Diaphragm pressure gauge with switch function High quality case with bajonet ring NS 00/60 per EN 837-3 S, alternative safety

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm DMP P Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 00 mbar up

More information

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm Industrial Pressure Transmitter Process Connections With Flush Welded Stainless Steel accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO from 0... 00 mbar up to 0... 0 bar Output signals

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 00 bar Output

More information

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor Precision Pressure Transmitter for the Process Industry with HART -Communication Stainless Steel Sensor accuracy according to IEC 0770: 0. % FSO Nominal pressure from 0... 00 mbar up to 0... 00 bar Output

More information

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request

More information

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO. ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma

More information

Flow measurement of Liquids and Gases

Flow measurement of Liquids and Gases Flow measurement of Liquids and Gases Metallic construction Operates horizontally or vertically DN 40 to DN 500 Flow rate: - Water: 0.8 m 3 /h up to 1600 m 3 /h. - Air: 45 Nm 3 /h up to 24000 Nm 3 /h.

More information

Field case for temperature transmitter Model TIF11

Field case for temperature transmitter Model TIF11 Electrical temperature measurement Field case for temperature transmitter Model TIF11 WIKA data sheet TE 62.02 Applications Plant construction Process engineering General industrial applications Energy

More information

Magnetic float switch For vertical installation Model FLS for nuclear power plants

Magnetic float switch For vertical installation Model FLS for nuclear power plants Level measurement Magnetic float switch For vertical installation Model FLS for nuclear power plants KSR data sheet FLS for NPP for further approvals see page 3 Applications Level measurement for almost

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Liquid level switch BW 17

Liquid level switch BW 17 KROHNE 09/2001 7.02369.21.00 GR/PRINTO Liquid level switch Status: 10/99 Variable area flowmeters Vortex flowmeters Flow controllers Electromagnetic flowmeters Ultrasonic flowmeters Mass flowmeters Level

More information

Bypass Level Indicator / Functional description

Bypass Level Indicator / Functional description Bypass Level Indicator / Functional description Functional description Bypass level indicators form an integral part of the pressure vessel. Via two process connections a standpipe ( bypass ) is mounted

More information

O O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers)

O O Pressure: max. PN 100 / Class 600. O O Temperature: -40 C C (ceramic rollers) 0 C C (PP-rollers) ypass Level Indicators ATEX or GL Approval measuring monitoring analysing NK -ATEX,-GL -03, -06, -07, -10 O O Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart O O Pressure:

More information

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0. Precision Pressure Transmitter for Food ndustry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to EC 60770: 0. % FSO Nominal pressure from 0... 400 mbar up to 0... 40 bar Output

More information

Diaphragm pressure gauge per EN 837-3,

Diaphragm pressure gauge per EN 837-3, Diaphragm pressure gauge per EN 837-3, chemical design, NS 100/160,Type series BA2 Features Diaphragm pressure gauge Nominal ranges -400 mbar to -1...24 bar, 0 25 mbar to 0 25 bar High quality case with

More information

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases Low cost, excellent readability and light weight Simple installation (flanged, threaded or socket ends for solvent or

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

Measuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600

Measuring length: single-part max mm über 5500 mm two-part or multipart. Pressure: max. PN 100 / Class 600 Bypass Level Indicators ATEX or GL Approval measuring monitoring analysing NBK -ATEX,-GL -03, -06, -07, -10 Measuring length: single-part max. 5500 mm über 5500 mm two-part or multipart Pressure: max.

More information

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420.

Data Sheet. Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology. Vortex meter trikon EDZ 420. Data Sheet Measuring System trikon Vortex Flow Meter EDZ 420 in Microprocessor Technology Application Metering and recording of volume or mass flow of gases, liquids and steam. Vortex meter trikon EDZ

More information

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview Overview Design and operation The main components of the Tubux variable area meters are the glass variable-area flow tube with float, the fitting and the connection parts. The flow is displayed directly

More information

TURBINE METER RQ Series 1 and 2

TURBINE METER RQ Series 1 and 2 1. IDENTIFICATION Manufacturer Bopp & Reuther Messtechnik Am Neuen Rheinhafen 4 67346 Speyer / Germany Phone: +49 6232 657-0 Fax: +49 6232 657-505 Product type Indirect volume meter Product name Turbine

More information

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma

TTL-Exd. Thermocouple Thermometers. Ignition Protection Exd. NiCr-Ni or Fe-CuNi thermocouples. Output: sensor or analogue 4-20 ma Thermocouple Thermometers Ignition Protection Exd measuring monitoring analysing TTL-Exd T2 O O Measuring ranges: max. 1100 C OO NiCr-Ni or Fe-CuNi thermocouples OO Output: sensor or analogue 4-20 ma O

More information

LIQUID METER TYPE FMO

LIQUID METER TYPE FMO LIQUID METER TYPE FMO INNOVATORS IN FLOW TECHNOLOGY FLUX LIQUID METER TYPE FMO OVAL ROTOR DESIGN FLUX liquid meters type FMO are positive displacement flowmeters according to the oval rotor design. They

More information

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid Screw-Type Volumetric Flow Meter for Viscous Media measuring monitoring analysing OM... Measuring ranges: 0.-0... 0-000 l/min liquid OMeasuring O accuracy: ± 0.% of span : 00 ± 0.% of span : 0 p max :

More information

OPTIMASS 7400 Technical Datasheet

OPTIMASS 7400 Technical Datasheet OPTIMASS 7400 Technical Datasheet Sensor for mass flow The optimum meter for demanding applications A single straight measuring tube Choice of 4 tube materials The documentation is only complete when used

More information

DON. Oval Wheel FIowmeter. for low and high viscous liquids. Measuring range: l/h und l/min

DON. Oval Wheel FIowmeter. for low and high viscous liquids. Measuring range: l/h und l/min Oval Wheel FIowmeter for low and high viscous liquids measuring monitoring analysing DON Measuring range: 0.5 36 l/h und 150 2500 l/min Viscosity range: 0 0 cp (higher on request) Accuracy: ±0,2 % 1% of

More information

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR

KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR KAL-K & KAL-A COMPACT THERMAL FLOW SENSOR Flow Pressure Level Temperature measurement monitoring control Revolutionary Microprocessor-Based Drift Stabilization NPT and 3-A Compliant Sanitary Fittings Non-Corrosive

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Cost savings due to high accuracy Low investment cost through

More information

SITRANS P measuring instruments for pressure

SITRANS P measuring instruments for pressure Overview Supplementary electronics for 4-wire connection Structural design Dimensions (W x H x D) in mm (inch) Electrical connection 80x10x60 (3.15x4.7x.36) Screw terminals (Pg 13.5 cable inlet) or Han

More information

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications VersaFlow Coriolis 200 Sensor for Mass Flow Specifications 34-VF-03-12 June 2011 The Solution for Bulk Mass Flow Measurement The VersaFlow Coriolis 200 has been developed to meet the demanding transfer

More information

DMH. Magnetic Inductive Flowmeter. for conductive fluids

DMH. Magnetic Inductive Flowmeter. for conductive fluids Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C Connection:

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 May 2009 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications Technical Datasheet Pressure Switch Models: CS2 & CS4 Key Features Compact and rugged design. Stainless steel weatherproof enclosure IP66 / NEMA 4X Hermetically sealed SPDT or microswitch ATEX / IECEx

More information

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0.

DMH. Magnetic Inductive Flowmeter. for conductive fluids. Measuring range: m 3 /h. Accuracy: ± 0.3% of reading ± 0. Magnetic Inductive Flowmeter for conductive fluids measuring monitoring analysing MH Measuring range: 0.05 40376 m 3 /h ccuracy: ± 0.3% of reading ± 0.01% x Q max p max : PN40; t max : -20... +150 C O

More information

MAN-U. Differential Pressure Gauges. for high static pressures up to 200 bar. Housing: 100 mm, 150 mm

MAN-U. Differential Pressure Gauges. for high static pressures up to 200 bar. Housing: 100 mm, 150 mm Differential Pressure Gauges for high static pressures up to 200 bar measuring monitoring analysing MAN-U Housing: 100 mm, 150 mm Material Housing: stainless steel Connection: stainless steel Movement:

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries 2 TSHY RESISTANCE THERMOMETER FOR THE FOOD AND BEVERAGE INDUSTRIES

More information

TOPAS PMG / PMH Hydraulic sensor Hot water

TOPAS PMG / PMH Hydraulic sensor Hot water TOPAS PMG / PMH Hydraulic sensor Hot water Applications The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Features Insensitive to turbulences

More information

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables Data Sheet 907025 Page 1/12 Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables The hygrothermal transducers measure the relative air humidity and temperature

More information

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. : +200 C OScrew O thread: G ¼... G 4. t max. Rp 1...

MFR / MFF / MFT. Magnetic Filters and Dirt Traps : PN 40. p max. : +200 C OScrew O thread: G ¼... G 4. t max. Rp 1... Magnetic Filters and Dirt Traps measuring monitoring analysing MFR / MFF / MFT OO p max : PN 40 OO t max : +200 C OScrew O tread: G ¼... G 4 OScrew O tread: Rp 1... Rp 2 OFlanges: O DN 50... DN 200 OSolder

More information

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications VersaFlow Coriolis 1000 Mass Flow Sensor Specifications 34-VF-03-03 June 2012 The Superior Solution The VersaFlow mass flow sensor is the only mass flow sensor with a straight measuring tube that is available

More information

TOPAS PMG Hydraulic sensor hot water

TOPAS PMG Hydraulic sensor hot water TOPAS PMG Hydraulic sensor hot water O f c c b a b d a d 5657244 5657264 565139.4 The hydraulic sensors form part of a heat meter and operate according to the multiple-jet measuring principle. Applications

More information

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty

More information

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER WP-SDC Copper Can Register Woltman (Turbine) Belanto WP-SDC is TURBINE Woltman water meter with magnetic transmission, super dry type register for industrial

More information

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits RHM60 Coriolis Mass Flow Meter with Uncompromising Performance Features Standard pressure ratings up to 490 bar (7107 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters No. SS2-GTX00G-0100 (Rev.9) AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos. průmyslová elektronika Capacitive level meters CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and

More information

Prosonic Flow B 200. For reliable flow measurement of biogas without limitations

Prosonic Flow B 200. For reliable flow measurement of biogas without limitations Prosonic Flow B 200 For reliable flow measurement of biogas without limitations Specially designed ultrasonic flowmeter for measuring biogas, landfill or digester gas One-of-a-kind direct measurement of

More information

Pressure transducers DMU 02 Vario (flush)

Pressure transducers DMU 02 Vario (flush) Process engineering (flush) Ideal for hygienic processes Connection technology with numerous versions Extremely resistant to shock, pulsation and vibration Best dynamic pressure resistance at high load

More information

Presented By. NicolScales.com Contact Us

Presented By. NicolScales.com Contact Us Presented By Dallas Ft Worth Austin Houston NicolScales.com 800.225.8181 Contact Us Nicol Scales & Measurement is an ISO Accredited Calibration Company that has provided calibration, repair and sales of

More information

VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications

VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications 34-VF-03-27, July 2017 The Solution for extended temperature applications A high level of performance, together with a wide operating temperature

More information

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates Data sheet DS/FPD510 EN IOMaster FPD510 Compact integral orifice flowmeter Low-cost measurement of small flowrates Compact flowmeter for small pipelines & flowrates available for pipe sizes 1 /2, 1 and

More information

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise

Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise HAASE Energietechnik AG, Neumünster Proline Prosonic Flow B 200 For reliable biogas flow measurement without compromise Process monitoring and energy balancing made easy Innovative measurement industry-optimized

More information

AT9000 Advanced Transmitter Gauge Pressure Transmitters

AT9000 Advanced Transmitter Gauge Pressure Transmitters No. SS2-GTX00G-0500 (Rev.3) AT9000 Advanced Transmitter Gauge Pressure Transmitters OVERVIEW AT9000 Advanced Transmitter is a microprocessor-based smart transmitter that features high performance and excellent

More information

Mechatronic pressure measurement. Applications. Special features. Description

Mechatronic pressure measurement. Applications. Special features. Description Mechatronic pressure measurement Diaphragm pressure gauge with switch contacts Model 432.56, high overload safety up to 100 bar Model 432.36, safety version, high overload safety up to 400 bar WIKA data

More information

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

FLUIDISTOR GAS FLOWMETER GD 100 (EX) FLUIDISTOR GAS FLOWMETER GD 100 (EX) for measuring of all technical and medical gases DN25 - DN400 Oscillating measuring principle, without moving parts Resistent to dirt, e.g. oil and rust residues in

More information

Large selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm

Large selection of standard versions. Special versions at customer request. Nominal sizes: 100, 125 and 150 mm Bi-metal Thermometers all Stainless Steel Construction measuring monitoring analysing TBE Fast response times Large selection of standard versions Special versions at customer request Nominal sizes: 100,

More information

digitalyewflo Series Vortex Flowmeter Installation Manual

digitalyewflo Series Vortex Flowmeter Installation Manual User s Manual digitalyewflo Series Vortex Flowmeter Installation Manual Manual Change No. 17-0024-E Please use the attachment sheets for the (2nd). No. Page / Addition/Correction Description Section 1

More information

sira IECEx Certificate of Conformity

sira IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

P430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information:

P430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information: P430 Series Glass Tube Variable Area Flow Meter Parker P Series glass tube flowmeters deliver unsurpassed performance and value in a wide variety of gas and liquid applications. P430 Series flow meters

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR FOOD AND BIOPHARMA. Product Information ITM-4 FOOD 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 SENSORS FOR AND BIOPHARMA. Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase

More information

ALTOFLUX IFS 4000/4005

ALTOFLUX IFS 4000/4005 KROHNE 03/2002 7.02351.22.00 GR ALTOFLUX IFS 4000/4005... result of more than 40 years experience with electromagnetic flowmeters Liner made of KROHNE Teflon -PFA or other fluorines Dimensionally stable,

More information

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2. SITRANS P DSIII Pressure Transmitters All versions of the SITRANS P transmitter, DS III series, are smart two-wire transmitters The output signal is a load-independent direct current of 4 to 20 ma proportional

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb)

Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb) Spec-01168 Hazardous Location Enclosures Hazardous Location Enclosures and Accessories Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb) APPLICATION Hazloc cable glands provide strain relief,

More information

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY Technical Datasheet TRICOR Series Mass Flow Meters Description The Tricor Mass Flow Meters measure simultaneously mass flow, volume flow, temperature and density and consequently can replace different

More information

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available

More information

Turbine Meter. P e

Turbine Meter. P e Turbine Meter P 402.003e Turbine Flow Meters Table of Contents Applications of the Turbine Meter RQ Series Page 3 Type RQ for Liquids Page 4 RQ Turbine Meter with UST Universal Transmitter Page 7 RQ Turbine

More information

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features EE300ExHT The EE300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL. CATALOG Variable Area Flowmeter EASYFLOW www.sedflowcontrol.com SMART IN FLOW CONTROL. Easyflow Applications Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment

More information

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications GE Sensing & Inspection Technologies Sentinel LNG Panametrics Ultrasonic Flowmeter for Cryogenic Liquids Benefits Improved performance, reduced maintenance and dynamic flow measurement is now available

More information

CAPACITIVE LEVEL METERS CLM 36

CAPACITIVE LEVEL METERS CLM 36 CAPACITIVE LEVEL METERS CLM 36 For continuous level measurement of liquid and bulk-solid materials Direct mounting into containers, silos, vessels, basins, reservoirs, etc Easy and quick connecting by

More information

Thermometer in stainless steel with vertical stem in stainless steel

Thermometer in stainless steel with vertical stem in stainless steel Ed.18.01 Design Thermometer in stainless steel with in stainless steel 1.4571 Design EN 13190 Case diameter Dim 63, 100 eller 160 mm Accuracy Class 1,0% acc.to DIN EN 13190 Type Case Glass 5500 = case

More information

VARIABLE AREA FLOWMETER EASYFLOW.

VARIABLE AREA FLOWMETER EASYFLOW. VARIABLE AREA FLOWMETER EASYFLOW www.sedflowcontrol.com EASYFLOW APPLICATIONS Monitoring of the flow of concentrate and recirculation of a Reverse Osmosis Water Treatment Plant Reverse Osmosis System Water

More information

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO Capacitive level meters CLM 36 Capacitive level meters Riels CLM are designed for continuous level measurement of liquids, powders and bulk-solid

More information

Coriolis Mass Flow Meter

Coriolis Mass Flow Meter Coriolis Mass Flow Meter P Series High Precision Coriolis Mass Flow Meter Xi an Tosilon Automation Co., Ltd No.299, Daqing Rd, Lianhu District, Xi'an Shaanxi, China Tel: +86-29-8823 8550 info@tosilon.com;

More information

VLM10 In-line Vortex Mass Flow Meter

VLM10 In-line Vortex Mass Flow Meter VLM10 In-line Vortex Mass Flow Meter Description The VLM10 in-line vortex flowmeter measures process fluid flow by detecting the frequency at which vortices are shed from an obstruction in the process

More information

Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas

Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas Thermo Scientific insertion turbine flowmeters have provided highly accurate and repeatable flow measurements for large pipeline applications

More information

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features HLX300ExHT The HLX300Ex humidity and temperature transmitter fulfils the requirements of the ATEX directives on intrinsically safe operating equipment for use in potentially explosive atmospheres in zone

More information

Eletta Flow Monitor for use in explosive atmospheres

Eletta Flow Monitor for use in explosive atmospheres NEWThe V-Ex Eletta Flow Monitor for use in explosive atmospheres For some time there has been a demand from the market to offer explosion proof versions. An increasing number of customers and end users

More information

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4 1 Product Information ITM-4 4-Beam-Turbidity Meter ITM-4 Application / Specified Usage Authorizations Turbidity measurement from 0 up to 5000 NTU resp. 0 up to 1250 EBC Filter monitoring Phase separation

More information

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application: SI-02 Electromagnetic Flowmeter for General Applications Description: Features / Universally applicable / Separate or compact measuring transmitter / Variety of lining material / DN15 to DN2000 / DIN-

More information

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual

Vibranivo Mononivo. Series VN 4000 MN Series. Instruction manual Vibranivo Mononivo Series Series VN 4000 MN 4000 Instruction manual 010516 1 UWT GmbH Westendstraße 5 Tel.: +49 (0)831 57123-0 Internet:www.uwt.de D-87488 Betzigau Fax: +49 (0)831 76879 E-Mail: info@uwt.de

More information

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc) Range and Sensor Limits Refer to Table 1 Zero and Span Adjustment Limits Zero and span values can be set anywhere within the range limits stated in Table 1. Span must be greater than or equal to the minimum

More information

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU TUFFy T3 side Mounting level controls Tuffy liquid level switches are float actuated devices designed for horizontal mounting in a tank or vessel through threaded or flanged pipe connections. The compact

More information

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S)

Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) Vortex Flowmeter FV4000 (TRIO-WIRL V) Swirl Flowmeter FS4000 (TRIO-WIRL S) For flow rate and volume measurement of liquids, gases and steam Fluid temperatures up to 400 C (752 F) High accuracy Short inlet

More information

Rotating Vane Level Monitor

Rotating Vane Level Monitor Rotating Vane Level Monitor measuring monitoring analysing Fixed shaft or cable shaft Bulk materials: 0.2 to 2.5 t/m 3 Max. particle sizes: 50 mm Temperature: max. 85 C Max. filling level: 5 m pmax: 0

More information

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting Ed.17.02 Design Type Case diameter in stainless steel for mounting in thermowell or for direct mounting F73 Dim 100 mm or 160 mm Accuracy Class 1,0% DIN EN 13190 Case Glass Stainless steel with bayonet

More information

Contact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications

Contact thermometer. Bimetal- or Gas actuated thermometer. Description. Features. Measuring ranges. Options. Applications Force Pressure Temperature Switch Contact thermometer Bimetal- or Gas actuated thermometer - Inductive contacts - Sliding contacts - Snap action contact - Class 1 acc. to DIN EN 13190 - Optional with liquid

More information

Tuffy II Liquid Level Controls with Electric Switches

Tuffy II Liquid Level Controls with Electric Switches Tuffy II Liquid Level Controls with Electric Switches D E S C R I P T I O N The Tuffy II Liquid Level Switches are float-actuated devices designed for horizontal mounting in a tank or vessel through threaded

More information

Micro Motion LNG Series Meters

Micro Motion LNG Series Meters Product Data Sheet PS-002079, Rev B February 2018 Micro Motion LNG Series Meters Global industry standard for liquefied natural gas metering A complete, dedicated Coriolis meter solution for LNG dispensing

More information

Load cell Pendeo Process and mounting kits

Load cell Pendeo Process and mounting kits Load cell Pendeo Process and mounting kits Digital weighing technology for maximum transparency and precision The digital compression load cells in the Pendeo Process series are specially designed for

More information

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features. VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet 34-VF-03-12 October 2009 Specification The solution for bulk mass flow measurement The VersaFlow Coriolis 200 has been developed to meet

More information

U6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS

U6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS ORIFICE PLATE FLOW INDICATOR U6 SERIE - Mounting in all positions - Construction: cast iron or stainless steel - For pipes from ND 40 up to ND 300 mm - Scale amplification from 2 to 10 - Accuracy: ± 2.5

More information

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership

Models A6100 & A6200 Purgemaster SNAP-IN Small Flowmeter. Long-term reliable performance flowmeters with low cost-of-ownership Data sheet DS/6/6EN Rev. K Models 600 & 600 Purgemaster SNP-IN Small Flowmeter Long-term reliable performance flowmeters with low cost-of-ownership High strength stainless steel body the body is corrosion

More information

Type Type 2000 Transducers. I/P & E/P Transducers

Type Type 2000 Transducers. I/P & E/P Transducers Type 2000 I/P & E/P Description Principle of Operation The Type 2000 I/P and E/P transducers utilize closed-loop pressure feedback-control for precision pressure output and minimized effects of temperature,

More information