Section SECTIONAL INSULATED STEEL DOORS

Similar documents
SECTIONAL ALUMINUM DOORS

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS

SECTION SECTIONAL OVERHEAD DOORS

Page 1 PRODUCT DESCRIPTION SECTION SECTIONAL OVERHEAD DOORS MODEL 900 PRODUCT FEATURES

SECTIONAL OVERHEAD DOORS SECTION SECTIONAL OVERHEAD DOORS PART 1 GENERAL

SECTION SECTIONAL OVERHEAD DOORS

WEATHER BREAKER MODEL 175 QUALITY DOOR SOLUTIONS SINCE 1947

.1 DAF 45-03, Designation System for Aluminum Finishes..2 American Architectural Manufacturers Association (AAMA).

SECTION SECTIONAL OVERHEAD DOORS

SECTION ELECTRIC FOUR FOLD DOORS MODEL 46 FLAT SHEETED

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION SECTIONAL OVERHEAD DOORS 422 SERIES INSULATED STEEL DOORS

The motor shall be high-starting torque, ball bearing, rated at 460 V, 3 phase

SECTION SECTIONAL OVERHEAD DOORS

Page 1 PRODUCT DESCRIPTION PRODUCT FEATURES

SECTION SECTIONAL OVERHEAD DOORS 432 SERIES INSULATED STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 418 SERIES INSULATED STEEL DOORS

Series - 1

SECTION SECTIONAL OVERHEAD DOORS 424 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 416 SERIES SECTIONAL STEEL DOORS

SECTION SECTIONAL OVERHEAD DOORS 522 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how?

SECTION SECTIONAL OVERHEAD DOORS THERMACORE AP MODEL 850 INSULATED STEEL DOORS

C. Section Metal Fabrications: Steel frame and supports.

HAAS-THERM. Commercial Insulated Steel Doors. Models CHT-710, CHT-716, CHT-732, CHT-780, and CHT-790

SECTION SECTIONAL OVERHEAD DOORS 592 SERIES THERMACORE INSULATED STEEL DOORS

Series - 1

800 Series Aluminum Overhead Doors, by Northwest Door Section ALUMINUM SECTIONAL DOORS Digicon Information Inc.

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

MISER-THERM. Commercial Insulated Steel Doors. Models CMT-610, CMT-616, CMT-680, and CMT-690

RAOUL WALLENBERG HIGH SCHOOL SECURITY COILING GRILLE SFUSD PROJECT NO SAN FRANCISCO UNIFIED SCHOOL DISTRICT SECTION 08330

SECTION Coiling Doors and Grilles Model 4320

SECTION SECTIONAL OVERHEAD DOORS 511 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

SECTION ROLLING STEEL DOORS

Aluminum Perforated Rolling Door

.1 Section Documents and samples to be submitted..2 Section Construction and demolition waste management and disposal.

F-SERIES: F SPECIFICATIONS Four-Fold Door Systems

F-SERIES: FF XT SPECIFICATIONS Exterior Swinging Four-Fold Door Systems

FABRICOIL BASIC January 10, 2006

SECTION OVERHEAD COILING DOORS

Submit shop drawings in accordance with Vale Specification SPEC

900 Series Steel Overhead Doors, by Northwest Door Section STEEL SECTIONAL DOORS Digicon Information Inc.

SECTION Coiling Counter Shutters

SECTION Coiling Counter Shutters

Therma Series Insulated Overhead Doors, by Northwest Door Section SECTIONAL DOORS Digicon Information Inc.

Model STORM GRILLE Brick or Straight Pattern High Stress Rolling Grilles

FF200, FOUR-FOLD DOORS CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

JAMISON SOUND DOOR SPECIFICATIONS VERTICAL SLIDING SOUND REDUCTION DOOR - STC 53 POWERED OPERATION

SECTION OVERHEAD COILING SHUTTERS

SECTION Overhead Coiling Doors

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

SECTION [ ] SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

DETENTION / SECURITY WINDOWS SECTION 08660

SECTION SECTIONAL DOORS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

1. Section "Metal Fabrications" for miscellaneous steel supports.

SECURITY WITH SOPHISTICATED STYLE

SECTION Motor Operated Horizontal Sliding Sound Control Door

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

ADDENDUM NO. 4 Oct. 18, 2016 NEW SIMPSONVILLE FIRE STATION NO. 5 SIMPSONVILLE, SOUTH CAROLINA SCNA PROJECT NO. 1512

SECTION ACCORDION FOLDING PARTITIONS

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

SECTION [ ] ROLLING STEEL DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION COILING DOORS AND GRILLES

OPTIONS ARE LISTED IN RED, PLEASE MODIFY THESE AREAS AS NEEDED BASED ON YOUR PROJECT CONSULT MANUFACTURER FOR ADDITIONAL OPTIONS OR MODIFICATIONS.

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

SECTION ALUMINUM HANDRAIL SYSTEMS

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

The fire resistance required for doors in this building is 1 (one) hour resistance in compliance with the below general specifications:

Submit shop drawings in accordance with Vale Specification SPEC

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION NON--STRUCTURAL METAL FRAMING

Westgate Entrematic, Parking Security Gates Section OVERHEAD SECURITY GATE Prepared by: Digicon Information Inc. Page 1

SECTION IMPACT RESISTANT WALL PROTECTION

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

STEEL WINDOWS & DOORS SECTION 08510

SECTION RESIDENTIAL OVERHEAD DOORS IMPRESSION STEEL COLLECTION STEEL DOORS 5800 SERIES

This Addendum forms part of the Tender Documents and amends the Tender Documents as described below.

SECTION OVERHEAD COILING DOORS 790 SERIES OVERHEAD COILING SHEET DOORS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

L-SERIES: LTH3900 SPECIFICATIONS Stainless Steel Hollow Metal Sliding Fire Door System

Soundmaster & Modernfold TECHNICAL DATA

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

N-SERIES: NTH3500 SPECIFICATIONS Hollow Metal Sliding Door System

Central Dartmouth Section Exterior Envelope Renovations METAL-CLAD WOOD DOORS Page 1 of 5 Dartmouth, NS

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS


DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

FoldingAccess Series Aluminum Folding Door System

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SECTION METAL DOORS & FRAMES

SECTION NON-STRUCTURAL METAL FRAMING

SECTION OVERHEAD COILING DOORS 780 SERIES OVERHEAD COILING SHEET DOORS

Transcription:

1 GENERAL 1.1 GENERAL REQUIREMENTS General Conditions and Division 01 apply to this section. 1.2 RELATED WORK Section 05500: Miscellaneous Metal Fabrication Section 07900: Joint Sealers Section 09900: Painting and finishing Section 11169: Loading Dock Equipment Division 16: Electrical power supply to Electrical Operators 1.3 QUALITY ASSURANCE 1.3.1 Design doors and tracks to withstand basic wind load while in the closed position of 0.47 kpa (10 psf). Maximum deflection while the door is in open horizontal position shall not exceed 1/120 of the span. 1.3.2 Installation shall be only by the specified manufacturer or an authorized representative for the region. 1.4 SUBMITTALS 1.4.1 Submit detailed shop drawings to the Consultant for review, in accordance with Section 01300. 1.4.2 Shop drawings shall clearly show and describe in detail, detailed door assemblies and adjacent construction. Show elevations, sections and details and clearances required for the door assemblies. 1.4.3 Shop drawings shall be of best quality craftsmanship, specifically prepared on one standard size drawing sheet. 1.4.4 Door manufacturer shall provide complete installation instructions for doors and hardware. 1.4.5 Provide a letter of conformance indicating that the doors are installed in accordance to the drawings and the specifications 2 PRODUCTS 2.1 MANUFACTURER 2.2 Standard of Acceptance: Thermatite door model T175 MR 45 mm (1 3/4 ) thick insulated as manufactured by Richards-Wilcox Canada Inc., with minimum requirements as specified herein: 2.3 Alternates will be considered provided they meet the minimum specification within and are approved & accepted in writing prior to tender closing. 2.3 MATERIALS 2.3 Door Sections: 2.3.1 Steel skins with polyurethane core sandwich type construction, thermal break and to incorporate the use of two continuous replaceable factory installed gaskets. Sections shall have a minimum thermal insulating value of RSI 2.82 (R16). Richards-Wilcox Canada T175MR Page 1 of 5

2.3.2 Exterior Skin: Structural quality hot-dipped galvanized steel, 0.48 mm (0.019 ) minimum embossing, factory applied baked on polyester paint finish, shall have non-repeating random stucco texture and Multi-Ribbed profile. 2.3.3 Interior Skin: Structural quality hot-dipped galvanized steel, 0.41 mm (0.016 ) minimum, baked-on acrylic paint finish, non-repeating random stucco texture and rib pattern. 2.3.4 Ends of each door section shall be caped with 1.6 mm (0.0625 ) hot dipped galvanized steel full height end caps. Doors width 16-3 (4953 mm) and over shall all have double end caps. 2.3.5 Insulation: Cavity shall be filled on continuous process, formed-in-place, CFC and HCFC free rigid polyurethane core, interior and exterior skins shall feature thermal break. 2.3.6 Reinforcements: Provide 0.9 mm (0.039 ) minimum, continuous reinforcing strip, within core of door sections, for all hardware, accessories and mounting locations. Reinforcing strip must be of adequate width to enable the attachment of all fasteners and screws to penetrate both door interior skin and reinforcing strip. Fasteners or screws etc., secured only to the door skin will not be acceptable. 2.3.7 Weather-stripping: Doors shall be equipped with a heavy duty, factory installed continuous top seal to seal against header, continuous replaceable seals between sections and vinyl bulb shaped astragal on the bottom edge of the bottom section. Dual Durometer vinyl jamb weather seal bolted to the continuous adjustable mounting angle (ADCA) for easy replacement, as supplied by Richards- Wilcox Canada. 2.3.8 Full View Sections: Provide full view sections fabricated from clear anodized tubular aluminum extrusions complete with 13 mm (½ ) thick thermal glazing as per architectural drawings. 2.3.9 Door Finish: Interior and exterior finish shall be door manufacturer s standard Silver colour. 2.3.10 Trusses: If required, provide adequate number of galvanized steel linear type reinforcing trusses to meet the wind loading. 2.4 HARDWARE 2.4.1 Standard of Acceptance: Linear Hardware System as manufactured by Richard-Wilcox Canada. Doors shall be equipped with double end roller brackets and long stem rollers. 2.4.2 Finish: Door tracks and track mounting hardware and torsion assembly mounting brackets shall be hot-dip galvanized. 2.4.3 Track: 2.7 mm (12ga), thick commercial galvanized track, formed track 80 mm (3 1/8 ) overall outside dimension. Vertical track sloped for weather tight closing. 2.4.4 Track Angle: Continuous adjustable track angle (ADCA), bolted type, field adjustable to ensure weather tight seal and serviceability, fabricated from 2.4 mm (13ga) commercially galvanized steel, designed to provide continuous support to the vertical track. Combination angle and clip mounting not acceptable. 2.4.5 Hinges: Linear type, fabricated from 2.75 mm (12ga) thick galvanized steel with embossments designed to resist higher load and to provide greater stability and improved performance. Doors width 16-3 (4953 mm) and over shall have double end hinges featuring full width bushing for both the hinge pivot and roller carries to allow for ease installation and eliminating any possibility of misalignment of the hinges. 2.4.6 Track Hangers: Minimum 32 x 32 mm (1 1/4 x 1 1/4 ) steel angles roll formed from 2.0 mm (0.078 ) commercially galvanized steel. Richards-Wilcox Canada T175MR Page 2 of 5

2.4.7 Weather-stripping: Doors shall be equipped with a heavy duty, factory installed continuous top seal to seal against header, continuous co-polymer joint bulb seal between sections and vinyl bulb shaped astragal on the bottom edge of the door. Dual Durometer vinyl jamb weather seal bolted to the continuous adjustable mounting angle (ADCA) for easy replacement, as supplied by Richards-Wilcox Canada 2.4.8 Rollers: Steel rollers 73 mm (2 7/8 ) diameter, with ten (10), 8 mm (5/16 ) diameter ball bearings, 11 mm (7/16 ) diameter roller axles and both inner and outer ball races of hardened steel. Length of roller stem as required. 2.4.9 Roller Brackets: Fabricated from 2.7 mm (12 ga) galvanized steel. 2.4.10 Shaft and Counter Balance Springs: Helically wound torsion springs manufactured from oil tempered spring wire stress relieved, minimum 10,000 cycles. Aluminum die cast grooved drums and flexible galvanized aircraft cables, 7 x 19 construction, mounted on minimum 25 mm (1 ) CRS solid steel shaft, keyed full length, rolling on flange bearings. 2.4.11 Bumper springs to be installed at the end of each horizontal track to prevent door over travel. 2.4.12 Track Guards: Continuous 4.7 mm, thick x 1524 mm, high (3/16 x 5-0 ) chamfered at top at 45 degrees, painted safety yellow finish. 2.5 Doors quantity, size and the lift type as shown on door schedule and/or architectural drawings. 2.6 ELECTRIC OPERATORS 2.6.1 Provide Jack shaft type electric operators for doors as shown on Drawings, having sufficient power to operate the door at an approximate speed of 200 mm (8 ) per second. 2.6.2 Jack Shaft Operator: Lift Master industrial duty logic control type operator with on board radio receiver, model H to NEMA 1, shall be equipped with an adjustable friction clutch, time delay on reverse, solenoid brake integral enclosure containing the controls and floor level disconnect and emergency manual chain hoist assembly with electrical interlock, motor HP minimum, suitable for volts, _ Ph, 60 Hz power supply. a) Provide one push button station OPEN/CLOSE/STOP to NEMA 1, for inside wall mounting near the door jamb on the operator side. b) Provide and install a Featheredge Reversing Safety Edge along the bottom edge of door to reverse on contact with an object as supplied by Service Door Industries. Hose type pneumatic safety edges will not be accepted. Power to the safety edge shall be supplied through reelite. 2.6.3 Power supply and fused disconnect near the opening on the operator side by division 16. Wiring from the fused disconnect to the operator and to the controls by the door contractor. 3 FABRICATION 3.1 Fabricate the work true to dimensions detailed and square, and to reviewed shop drawings, free from distortion and defects detrimental to the appearance and performance. Richards-Wilcox Canada T175MR Page 3 of 5

3.2 Ensure that Site dimensions are taken prior to the fabrication of the doors. 3.3 Door shall be 25 mm (1 ) higher than finished opening height and extend 25 mm (1 ) beyond jamb on either side of finished opening. 3.4 Use shop and field connections complying with CAN/CSA S16.1-M. 3.5 Accurately fit joints and intersecting members with adequate fastenings. 4 EXECUTION 4.1 EXAMINATION 4.1.1 Prior to commencement of work of this Section, thoroughly examine location where door(s) and all other related components are to be installed. To ensure a satisfactory installation, the door installer must inspect the opening to ensure it is square and true, and that the floor is level to ensure proper seal at the floor. 4.1.2 Report in writing, to the Consultant, any condition adversely affecting this work. 4.1.3 Proceed with work only when conditions are satisfactory for the installation. 4.2 INSTALLATION 4.2.1 Installation shall be by door manufacturer or by authorized manufacture s representative for the region, as specified herein. 4.2.2 Install doors, tracks and operating equipment complete with necessary hardware, weather-stripping, anchors, hangers, brackets and accessories, in accordance to manufacturer's printed instructions. 4.2.3 Assemble and erect work plumbs, true, square, straight, level and accurate as per Drawings and reviewed shop drawings. 4.2.4 Isolate metals where necessary to prevent corrosion due to contact with dissimilar metals and between metals, masonry and concrete. Use bituminous paint or butyl tape or as recommended by the door manufacturer. 4.2.5 Supply written instructions, drawings, and where necessary provide supervision for the installation of items to be built in by work of other Sections. 4.2.6 Steel member s etc. including jamb extensions and spring pads, by Division 5 and as per structural drawings. All other mounting brackets, angles etc., required for the proper installation of work of this Section, shall be the responsibility of the door manufacturer. 4.2.7 Complete installation must be to the satisfaction of the Consultant. Any and all aspects of installation adversely affecting appearance and/or performance of such installation shall be deemed unacceptable and shall be fully replaced at no additional cost to the Owner 4.3 DOOR: 4.3.1 Install sectional door in strict accordance with final reviewed shop drawings, manufacturer s instructions and as specified herein. 4.3.2 Fit, align and adjust overhead door assemblies, level and plumb, to ensure smooth operation and to provide correct closure to the satisfaction of the Consultant. Richards-Wilcox Canada T175MR Page 4 of 5

4.3.3 Ensure that complete installation includes tracks, operating equipment, necessary hardware, weatherstripping, anchors, hangers, brackets and any other accessories deemed necessary. Include any other items, not specified herein, but is required for a complete installation. 4.4 HARDWARE: 4.4.1 Install all necessary hardware, jamb and head mold strips, anchors, inserts, hangers and equipment supports in accordance with final reviewed shop drawings, manufacturer s instructions and as specified herein. 4.4.2 Mount counterbalancing mechanism with brackets at each end of shaft and at maximum 2438 mm (8-0 ) o/c. in between. 4.4.3 Fasten vertical track assembly to opening frame at maximum 508 mm (1'-8") o/c. vertically. Install additional track anchors where deemed necessary by the Consultant. 4.4.4 Support the horizontal track to transmit the door dead and operating loads to the building structure. Install sufficient supports, anchors, fasteners etc. so that the track assembly is rigid and free from undue movement as required by the door manufacturer and to the satisfaction of the Consultant. Install additional track anchors where deemed necessary by the Consultant. 4.4.5 Provide bumper springs at the end of each track of manually operated doors. 4.4.6 Ensure weather-stripping properly fastened and it forms a continuous weather-tight seal at perimeter. 4.5 ADJUSTMENT AND DEMONSTRATION 4.5.1 Lubrication: 4.5.2 Upon completion of installation of doors and operating equipment, lubricate moving parts before operation. 4.5.3 Grease sprockets, bearings, cables, link chains and guides. Lubricant shall be as recommended by the manufacturer. 4.6 Demonstration: 4.6.1 Test the door operation and adjust doors for smooth operation, free from warp, twist or distortion. Demonstrate the operation to the satisfaction of the Consultant at the same time of acceptance of the completed work. 4.6.2 Submit to the Owner a copy of proposed preventative maintenance program for overhead doors and other related components requiring regular maintenance and check-ups. END OF SECTION 08360 Richards-Wilcox Canada T175MR Page 5 of 5