K5 External Wall Board

Similar documents
K5 External Wall Board

K12 Framing Board. Insulation

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS

K12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS

K8 Cavity Board. Insulation CAVITY WALL INSULATION

K17 Insulated Plasterboard

K3 Floorboard. Insulation INSULATION FOR FLOORS

Soffit Board. Insulation

K17 Insulated Plasterboard

K3 Floorboard. Insulation INSULATION FOR FLOORS

K18 Insulated Plasterboard

K17 Insulated Plasterboard

TR26 LPC/FM / TR27 LPC/FM

Timber-framed Walls. Insulation

TR26 LPC/FM / TR27 LPC/FM

K10 FM Soffit Board. Insulation

Brick Veneer Walls. Insulation

Double Brick Cavity Walls

A4/6 PS AW1551 Issue 4 Nov Permishield

TR26 LPC/FM. Insulation INSULATION FOR FLAT ROOFS WATERPROOFED WITH MECHANICALLY FIXED SINGLE PLY WATERPROOFING

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Tapered Roofing Systems

K5 EWB. Insulation INSULATION FOR USE BEHIND TRADITIONAL AND LIGHTWEIGHT POLYMER MODIFIED RENDERS P E R F O R M A N C E

A4/8 PS AW2324D Issue 10 May Permishield

A4/8 PS AW2002 Issue 6 Sept Permishield

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

TR27 LPC/FM. Insulation

Insulation. A4/6 AW2242 Issue 1 Oct Kingspan Insulation

Insulwhite. Insulation WHITE-FACED THERMO REFLECTIVE INSULATION

Retroshield XL TM. Insulation THERMO REFLECTIVE INSULATION

Insulation. CI/SfB n7 (M2) First Issue January zero ODP. Kingspan. Assessed to ISO 9001: 2000 Certificate No. 035/2

Insulbreak. Insulation. thermal break solution

Permifloor. Insulation WATER-PERMEABLE UNDERFLOOR INSULATION

Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB. (45) Rn7 M2 Fifth Issue May 2018

CI/Sfb 2- Rj7 - Eighth Issue May 2011

Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB. (45) Rn7 M2 Second Issue October 2016

KINGSPAN KOOLDUCT SYSTEM. Product. Scope. Building Regulations. Appraisal No. 771 [2017]

K5 EWB. Insulation INSULATION FOR USE BEHIND TRADITIONAL AND LIGHTWEIGHT POLYMER MODIFIED RENDERS P E R F O R M A N C E

K10 FM Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. agent that has zero ODP and low GWP

Permicav XV TM NEXT GENERATION OF VAPOUR-PERMEABLE INSULATION FOR WALLS WITH CAVITIES

Certificate No: EWS545C

Platinum. I n s u l a t i o n INSULATION FOR FLOORS. Low Energy Low Carbon Buildings

Insulbreak. Insulation. thermal break solution

Solutions. Main Headings Third Issue July Insulation DON T COMPROMISE ON THERMAL PERFORMANCE, FIRE PERFORMANCE AND ENVIRONMENTAL RESPONSIBILITY

Kooltherm FM. Quick Guide HVAC & Building Services Pipe Insulation. UK & Ireland

K10 Soffit Board. I n s u l a t i o n. Low Energy Low Carbon Buildings

K10 FM Soffit Board. I n s u l a t i o n. Low Energy Low Carbon Buildings

Engineered Timber Systems AN INTRODUCTION. Low Energy Low Carbon Buildings. CI/SfB (2-) Rj7 - Thirteenth Issue September 2017

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Fourth Issue August 2018

Fire Safety Compliance Guide: Wall and Ceiling Linings

K2 Roofboard INSULATION BENEATH FULLY ADHERED SINGLE-PLY WATERPROOFING USING SOLVENT BASED ADHESIVES P E R F O R M A N C E

Insulation. A4/8 KDINT AW2143 Issue 4 Oct An Introduction

K15 Rainscreen Board. I n s u l a t i o n EP E R F O R M A N C. Low Energy - Low Carbon Buildings

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS. P E R F O R M A N C E Manufactured to BS EN ISO 9002: 1994 Certificate No.

Insulation AN INTRODUCTION. Low Energy Low Carbon Buildings. Third Issue September 2017

K110 Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB

K15 Rainscreen Board. Insulation INSULATION FOR USE BEHIND RAINSCREEN CLADDING SYSTEMS P E R F O R M A N C E

K12 Framing Board. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

CI/Sfb (2 ) Rn7 M2 Fourth Issue June Product Selector INSULATION FOR ROOFS, WALLS & FLOORS. Low Energy Low Carbon Buildings

Fire Safety Compliance Guide: Wall and Ceiling Linings

Kingspan Kooltherm K10, K10 Plus & K15 Insulation Products

K12 Framing Board. I n s u l a t i o n. Low Energy Low Carbon Buildings

K8 Cavity Board. Insulation PARTIAL FILL CAVITY WALL INSULATION P E R F O R M A N C E BBA BRITISH

K5 External Wall Board

Kingspan Facades Rainscreen Systems Overview

Insulation TECHNICAL DATA SHEET. Low Energy Low Carbon Buildings. CI/SfB (57.9) In7 (M2) First Issue April 2016

K10 Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) P E R F O R M A N C E

Technical Submission Spiralite Pre-insulated Ductwork

K11 Roofboard. I n s u l a t i o n. Low Energy Low Carbon Buildings

TR24. I n s u l a t i o n. Low Energy Low Carbon Buildings

Product Catalogue

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

TW55. Insulation INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS

Sikatherm PIR GT. PIR Thermal Insulation Board. Product Description. Product Data

wall TW50 zero ODP PARTIAL FILL CAVITY WALL INSULATION For more information on Kingspan Insulation visit

K15 Cladding Board. Insulation INSULATION FOR USE BEHIND CLADDING SYSTEMS. Low Energy Low Carbon Buildings. Third Issue July 2017

K110 FM Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB

June Non - Residential Refurbishment 5.5 Basements

K12 Framing Board INSULATION FOR TIMBER AND STEEL FRAMING SYSTEMS P E R F O R M A N C E

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

K17 Insulated Plasterboard

June Residential Refurbishment Basements

Insulation. First Issue December Kingspan Insulation TECHNICAL SERVICES. Low Energy Low Carbon Buildings

Certificate No: EWWS545D2

K10 FM Soffit Board. Insulation INSULATION FOR STRUCTURAL CEILINGS (SOFFITS) Low Energy Low Carbon Buildings. CI/SfB

K103 Floorboard. Insulation INSULATION FOR FLOORS. Low Energy Low Carbon Buildings. CI/SfB. (13.9) Rn7 M2 Second Issue August 2016

Kooltherm FM. Quick Guide. HVAC & Building Services Pipe Insulation System. UK & Ireland

Superior Performance Phenolic Insulation. SR/RS Insulation for Ventilated Rainscreen Cladding. Walls 10/4803

First Issue March 2013 AN INTRODUCTION. Low Energy Low Carbon Buildings

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956

K2 Roofboard. Insulation INSULATION BENEATH FULLY ADHERED SINGLE PLY WATERPROOFING USING SOLVENT BASED ADHESIVES P E R F O R M A N C E

TW50. I n s u l a t i o n. Low Energy Low Carbon Buildings

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Insulation for Ventilated Rainscreen Cladding Systems

Don t leave money on the floor.

TECHNICAL. Cavity Wall Partial - Fill Insulation. Stylite.

KOOLTHERM K12 FRAMING BOARD AND K15 RAINSCREEN BOARD BCA Certificate number: CM Date of issue: 15/08/2017. Date of expiry: 21/03/2020

Transcription:

Insulation A4/6 K5 AW2161 Issue 5 Dec 2016 INSULATION FOR USE BEHIND TRADITIONAL AND LIGHTWEIGHT POLYMER MODIFIED RENDERS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Suitable for use behind traditional and lightweight polymer modified renders Transforms and upgrades the appearance of existing buildings Resistant to the passage of water vapour Easy to handle and install Ideal for new build and refurbishment Manufactured with a CFC/ HCFC-free blowing agent that has zero ODP and low GWP Compliant with AS/NZS 4859.1

Typical Constructions and Total R-values Insulated System on Concrete Wall Insulated System on Masonry Block Wall Bedding compound Bedding compound Structural concrete wall Masonry Block Wall Figure 1 Figure 2 50 R T 2.8 R T 2.8 80 R T 4.3 R T 4.3 50 R T 2.8 R T 2.8 80 R T 4.3 R T 4.3 Assumptions The R-values shown are Total R-values for the building element and are calculated in accordance with AS/NZS 4859.1 and NZS 4214. products are manufactured, tested and packaged in conformance with AS/NZS 4859.1. The contribution of the product Total R-values depends on installation and environmental conditions.

Insulated System on Steel-framed Wall Insulated System on Timber-framed Wall Metal stud Permeable membrane/sarking Timber stud Permeable membrane/sarking Counter batten Counter batten Figure 3 Figure 4 50 R T 3.1 R T 3.1 80 R T 4.6 R T 4.6 50 R T 3.1 R T 3.1 80 R T 4.6 R T 4.6

Product Details Product Description is a super high performance, fibre-free rigid thermoset phenolic insulation core, sandwiched between two layers of tissue based facing autohesively bonded to the insulation core during manufacture. is manufactured without the use of CFCs/HCFCs and has zero Ozone Depletion Potential (ODP) and low Global Warming Potential (GWP). Product Data Thermal Conductivity (λ-value) 0.020 W/m. K (Insulant thickness 45 mm) Product Dimensions 2270 mm x 1200 mm (2.72 m 2 ) 1200 mm x 600 mm (0.72 m 2 ) Product Thickness 50, 80 mm Other thicknesses available upon enquiry. Minimum order quantities apply Specification Guide The external wall insulation shall be K5 External Wall Board mm thick comprising a CFC/HCFC free and zero Ozone Depletion Potential (ODP) rigid thermoset phenolic insulation core with a tissue based facing on both sides manufactured under a management system certified to BS / I.S. EN ISO 9001:2008, BS / I.S. EN ISO 14001:2004 and BS / I.S. OHSAS 18001:2007 by Kingspan Insulation Limited and shall be installed by approved installers (please contact Kingspan Insulation). A Project Specific Warranty provided by Kingspan Insulation must be submitted. Standards and Approvals is manufactured to the highest standards and certified under the following management systems: Product R-value Product Thickness Product R-value 50 mm R2.5 80 mm R4.0 Standard BS / I.S. EN ISO 9001:2008 BS / I.S. EN ISO 14001:2004 BS / I.S. OHSAS 18001:2007 Product Testing Management System Quality Management Environmental Management Health and Safety Management Characteristic Standard Result Compressive Strength Water Vapour Resistivity BS / I.S. EN 826:1996 BS EN 12086:1997 / I.S. EN 12086:1998 Typically exceeds 120 kpa at 10% compression > 300 MN. s/g. m Fire Performance Test Test Method Result Figure 5 Super high performance K5 External Wall Board s The chosen render system must be pre-trialed and tested to ensure compatibility with the K5 External Wall Board. It is recommended that polymer modified renders be used for flexibility and adhesion, and that total coating be at least 6 mm thick for system integrity. Ignitability, Flame spread Heat release, Smoke release Flame Propagation (AS 1366) Fire Propagation Surface Spread of Flame AS 1530.3 AS 2122.1 BS 476 Part 6 BS 476 Part 7 Spread of Flame Index: 0 Smoke Development 4 Complies Class 0* (in accordance with the Building Regulations in England, Wales and Northern Ireland) *Applies only to the insulation core.

Installation Instructions Durability If correctly applied, products can be expected to have a long life of service. Their durability depends on the supporting structure and the conditions of its use. products are warranted for a period of 10 years for both residential and commercial installations.* * Subject to the terms of the complete warranty document which is available upon request or downloadable from www.kingspaninsulation.co.nz Environmental Data Aspect Recyclability Re-usability Characteristic Non-contaminated insulation site waste is recyclable, but there are currently no facilities in Australia to process returned material Re-usable if removed with care (long term of service expected) should only be installed by approved installers. For more information please call Technical Services on 09 969 1613 or email info@kingspaninsulation.co.nz. Handling and Storage The polythene packaging of should not be considered adequate for long term outdoor protection. Ideally, boards should be stored inside a building. If, however, outside storage cannot be avoided, then the boards should be stacked clear of the ground and covered with a polythene sheet or weatherproof tarpaulin. Boards that have been allowed to get wet should not be used. should be protected from getting wet during periods of inclement weather prior to the application of the weatherproof render. Water Use No water used in Kingspan Insulation s manufacturing process Blowing Agent Global Warming Potential (GWP) Blowing Agent Ozone Depletion Potential (ODP) Manufactured with a blowing agent that has low GWP Manufactured with a CFC/HCFC-free blowing agent that has zero ODP Packaging Contains 0% recycled product Polythene wrap and EPS skids 100% recyclable

Contact Details General Enquiries Tel: 0800 1 23 23 1 Email: info@kingspaninsulation.co.nz Kingspan Insulation Pty. Ltd. reserves the right to amend product specifications without prior notice. The information, technical details and fixing instructions etc. included in this literature are given in good faith and apply to uses described. Recommendations for use should be verified as to the suitability and compliance with actual requirements, specifications and any applicable laws and regulations. For other applications or conditions of use, Kingspan Insulation offers a Technical Advisory Service the advice of which should be sought for uses of Kingspan Insulation products that are not specifically described herein. Please check that your copy of the literature is current by contacting us or visiting www.kingspaninsulation.co.nz Kingspan Insulation Pty Ltd Tel: 0800 1 23 23 1 Email: info@kingspaninsulation.co.nz www.kingspaninsulation.co.nz Kingspan, Kooltherm, the zo Device and the Lion Device are Registered Trademarks of the Kingspan Group plc in Australia and other countries. All rights reserved. Kingspan Insulation Pty Ltd