The Effect of Cl - and Acetic Acid on Localized CO 2 Corrosion in Wet Gas Flow

Similar documents
Paper No. CORROSION

HIGH PRESSURE CO 2 CORROSION ELECTROCHEMISTRY AND THE EFFECT OF ACETIC ACID

THE EFFECT OF ACETIC ACID ON THE INTEGRITY OF PROTECTIVE IRON CARBONATE LAYERS IN CO 2 CORROSION OF MILD STEEL

IRON CARBONATE SCALE GROWTH AND THE EFFECT OF INHIBITION IN CO 2 CORROSION OF MILD STEEL

Paper No. CORROSION MODELING OF CO 2 CORROSION OF MILD STEEL AT HIGH PRESSURES OF CO 2 AND IN THE PRESENCE OF ACETIC ACID

A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO 2 CORROSION

Carbon Dioxide Corrosion in Wet Gas Annular Flow at Elevated Temperature

Paper No LOCALIZED CORROSION IN AN H2S / CO2 ENVIRONMENT

Effect of Chloride on Localized Corrosion Initiation of Carbon Steel in a CO 2 Aqueous Environment Xin Gao, Bruce Brown, Srdjan Nesic

ROLES OF PASSIVATION AND GALVANIC EFFECTS IN LOCALIZED CO 2 CORROSION OF MILD STEEL

KINETICS OF IRON SULFIDE AND MIXED IRON SULFIDE/CARBONATE SCALE PRECIPITATION IN CO 2 /H 2 S CORROSION

Effect of Oxygen on CO 2 Corrosion of Mild Steel. A thesis presented to. the faculty of

A Novel Method to Mitigate the Top of the Line Corrosion in Wet Gas Pipelines by Corrosion Inhibitor within a Foam Matrix

Paper No. CORROSION CO 2 CORROSION IN THE PRESENCE OF TRACE AMOUNTS OF H 2 S

Paper No Top of the Line Corrosion in H 2 S/CO 2 Environments

Rolf Nyborg and Arne Dugstad Institute for Energy Technology P.O. Box 40, N-2027 Kjeller, Norway

Localized Top of the Line Corrosion in Marginally Sour Environments

ABSTRACT INTRODUCTION

Combined Effect of CO 2, H 2 S and Acetic Acid on Bottom of the Line Corrosion

Paper No. Key words: CO 2 corrosion, carbide, iron carbonate, steel microstructure

Corrosion Behavior of Deep Water Oil Production Tubing Material under Supercritical CO 2 Environment: Part II. Effect of Crude Oil and Flow

Integrity of Corrosion Inhibitor Films in Multiphase Flow

Top-of-the-Line Corrosion in The Presence of Hydrocarbon Co-Condensation in Flowing Condition

Effect of Precorrosion and Temperature on the Formation Rate of Iron Carbonate Film

Top of Line Corrosion and Water Condensation Rates in Wet Gas Pipelines

Study of the Solubility of Iron Carbonate in the Presence of Acetic Acid using an EQCM

Influence of Hydrogen Sulfide on CO 2 Corrosion in Pipeline Steel

A thesis presented to the faculty of the. Fritz. J. and Dolores H.Russ College of Engineering and Technology of. Ohio University

Electrochemical Investigation of the Role of Cl on Localized CO2 Corrosion of Mild Steel

Multipronged Characterization of the Corrosion Product Layer Formed on Mild Steel after Exposure to Acetic Acid

Corrosion Mechanism of Carbon steel in MDEA-Based CO 2 Capture Plants ABSTRACT INTRODUCTION

Effect of Incorporation of Calcium into Iron Carbonate Protective Layers in CO 2 Corrosion of Mild Steel

A. Mohammed Nor, M.F. Suhor, M.F. Mohamed, M. Singer and S. Nesic

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning

Effect of Solution ph on Corrosion Product Layer Formation in a Controlled Water Chemistry System

Effect of Alloying Elements on the Corrosion Behavior of Carbon Steel in CO 2 Environments

Yang Yang 1, Bruce Brown and Srdjan Nesic Institute for Corrosion and Multiphase Technology 342 West State St. Athens, OH, U.S.A.

Effect of Alloying Elements on the Corrosion Behavior of Carbon Steel in CO 2 Environments

SIGNIFICANCE OF HYDROGEN EVOLUTION IN CATHODIC PROTECTION OF STEEL IN SEAWATER

ABSTRACT INTRODUCTION

Corrosion Rate Measurement on C-Steel

Effect of soil compositions on the electrochemical corrosion behavior of carbon steel in simulated soil solution

Localized Corrosion in the Presence of Corrosion Inhibitors at High Flow Velocities in CO 2 Environments

PRESENCE OF H 2 S. A dissertation presented to. the faculty of the

Top of Line Corrosion Testing for a Gas Field with Acetic Acid and Low CO 2

XII-EROSION-CORROSION MODELING AND EXPERIMENTS. Introduction

TOP OF THE LINE CORROSION IN SOUR ENVIRONMENT STUDY OF THE CONTROLLING PARAMETERS

Hydrogen Permeation of Pipeline Steel under Sour Condensate Film Condition

A thesis presented to. the faculty of. In partial fulfillment. of the requirements for the degree. Master of Science. Vanessa Fajardo Niño de Rivera

Laboratory Experiments in Corrosion Engineering II

Effect of Flow and Steel Microstructure on the Formation of Iron Carbonate

Ahmad Zaki B Abas Petronas Research SDN. BHD, Selangor Darul Ehsan, Malaysia ABSTRACT INTRODUCTION

Corrosion of Electrical Submersible Pumps (ESP) In South Rumaila Oil Field

DEVELOPMENT OF ELECTROLESS PROCESS FOR DEPOSITION OF ZN SILICATE COATINGS

Among the known options in carbon. capture and storage, the injection. and storage of carbon dioxide (CO 2

Key issues related to modelling of internal corrosion of oil and gas pipelines A review

CORROSION OF STEELS IN WATER AND HYDROGEN SULPHIDE

Investigation of Pseudo-Passivation of Mild Steel in CO 2 Corrosion

MECHANISTIC MODEL FOR THE PREDICTION OF TOP-OF-THE- LINE CORROSION RISK

CHAPTER 2 MATERIALS AND METHODS

STAINLESS STEEL SELECTION FOR FLUE GAS DESULFURIZATION EQUIPMENT

Chapter 6a Interpreting Stability (Pourbaix) Diagrams

Corrosion and inhibition of Cu-Zn alloys in NaCl solution by using permanganate and phosphate anions

Corrosion Behavior of Deep Water Oil Production Tubing Material Under Supercritical CO 2 Environment: Part 1 Effect of Pressure and Temperature

IPC TECHNICAL PAPER SERIES NUMBER 74 LOCALIZED CORROSION OF STAINLESS STEELS IN PAPER MACHINE WHITE WATER DAVID F. BOWERS FEBRUARY, 1979

Effect of Carbon Steel Composition and Microstructure on CO 2 Corrosion. A dissertation presented to. the faculty of. In partial fulfillment

Galvanic Corrosion of a Zn/steel Couple in Aqueous NaCl

ELEMENTAL SULFUR CORROSION OF CARBON STEEL IN THE PRESENCE OF SULFUR SOLVENT AND MONOETHYLENE GLYCOL

Effect of Paraffins on Carbon Dioxide Corrosion and Water Wetting in Oil-Water. Systems. A thesis presented to. the faculty of. In partial fulfillment

EROSION-CORROSION IN DISTURBED LIQUID/PARTICLE FLOW. A thesis presented to. the faculty of

Performance of corrosion inhibitors based on n-butylamine in protection of carbon steel in hydrochloric acid solution

Paper No. Effect of FeCO 3 Supersaturation and Carbide Exposure on the CO 2 Corrosion Rate of Carbon Steel

Surface films formed during H 2 S corrosion of pipeline steels and the effect on hydrogen permeation

THE RELATIONSHIP BETWEEN SURFACE TREATMENTS AND CORROSION RESISTANCE OF HOT-DIP GALVANIZED STEEL. Amirreza Bakhtiari

The Inhibition Chemistry of 2-Amino, 5-Phenyl 1, 3, 4-Triazole for Aluminium in Hydrochloric Acid Solution

Effect of Incorporation of Calcium into Iron Carbonate Protective Layers in CO 2 Corrosion of Mild Steel

Kinetics of Corrosion Layer Formation. Part 2 Iron Sulfi de and Mixed Iron Sulfi de/carbonate Layers in Carbon Dioxide/Hydrogen Sulfi de Corrosion

Improvement of corrosion resistance of HVOF thermal sprayed coatings by gas shroud

ABSTRACT INTRODUCTION

Development of Corrosion Inhibitors for Prevention of Top of the Line Corrosion (TLC)

Aegis Tech Line Aegis Chemical Solutions Technical Newsletter Volume 09, February 2019

2. Wet Corrosion: Characteristics, Prevention and Corrosion Rate

Effect of Fe ion concentration on corrosion of carbon steel in CO2 environment

Solubility of iron in carbonic acid solutions

Re-alkalisation technology applied to corrosion damaged concrete

ABSTRACT INTRODUCTION

Jin Huang, Bruce Brown, Yoon-Seok Choi and Srdjan Nešić

Corrosion Damage Monitoring of Stainless Steel by Acoustic Emission

POLARIZATION MEASUREMENTS ON IRON IN ALKALINE SOLUTIONS AT HIGH PRESSURES AND HIGH TEMPERATURES.

Galvanic corrosion evaluation of 6061 aluminum coupled to CVD coated stainless steel Elizabeth Sikora and Barbara Shaw 6/9/2016

COMPARISON OF OXIDATION POWER SENSOR WITH COUPLED MULTIELECTRODE ARRAY SENSOR FOR MONITORING GENERAL CORROSION

Corrosion and batteries

Galvanic Mechanism of Localized Corrosion for Mild Steel in Carbon Dioxide. Environments. A dissertation presented to.

A quasi 2-D localized corrosion model

SACRIFICIAL ANODE CATHODIC PROTECTION OF LOW CARBON STEEL IN SEA WATER

Predict 7.1 Product Information Note

Corrosion of Nickel Chromium Alloys in Molten Sodium Sulfate Salt at 900 C

Thermogravimetric Thin Aqueous Film Corrosion Studies of Alloy 22; Calcium Chloride Solutions at 150 C and Atmospheric Pressure

A Mechanistic Study of the Role of Pyrite in Localized Corrosion of Mild Steel

Predicting Effects of Corrosion Erosion of High Strength Steel Pipelines Elbow on CO 2

Transcription:

The Effect of Cl - and Acetic Acid on Localized CO 2 Corrosion in Wet Gas Flow Yuhua Sun, Keith George, and Srdjan Nesic NSF I/UCRC, Corrosion in Multiphase Systems Center Institute for Corrosion and Multiphase Technology Ohio University, Athens, OH 45701, U.S.A ABSTRACT Wet gas corrosion rates of C1018 and X65 steel have been measured at the top and bottom of a high pressure, 10 cm diameter horizontal pipeline under stratified flow conditions with different chloride (Cl - ) concentrations. Experiments were performed for 200 hours at 90 C, CO 2 partial pressure of 3.8 bar using a superficial gas velocity (Vsg) of 10 m/s and a superficial liquid velocity (Vsl) of 0.1 m/s. Three measurement techniques; ER, LPR, and WL were used simultaneously in the experiments. Localized corrosion occurred at the bottom of the pipe around the iron saturation point. The top of line was well protected by a thin corrosion product film and no localized corrosion was detected. C1018 and X65 have different sensitivities to pitting with a variation in Cl - concentration. Thus the pitting density concept is proposed to describe localized corrosion behavior. Surface analysis on iron carbonate films, by SEM and XRD, revealed different film thicknesses and crystal structures from the top to the bottom of the pipe. Cross-sectional analysis indicates that the thin corrosion product film, usually less than 10 microns, attached to the metal surface, is responsible for the low corrosion rate on top of the line, while the thick and porous film formed on the bottom, generally detached from the metal surface, was responsible for the initiation of localized corrosion. Before adding acetic acid (HAc) to the flow loop, a systematic glass cell test program was initiated using potentiodynamic sweeps to investigate the electrochemical properties of carbon dioxide corrosion in the presence of HAc. A standard rotating cylinder three-electrode setup was employed. Tests were performed to study the effect of HAc in solutions de-oxygenated using both nitrogen and carbon dioxide. The range of HAc concentrations was then expanded to study the effect of the concentration of HAc on the cathodic and anodic reactions in carbon dioxide solutions. The presence of HAc was found to not affect the corrosion rate of carbon steel at low temperature since the main cathodic reaction (hydrogen ion reduction) was found to be under charge transfer control. The limiting current was strongly affected by the HAc concentrations, but the charge transfer mechanism was not changed. The anodic reaction was retarded with increasing HAc concentrations but the mechanism stayed the same. The effect of ph, temperature and rotational velocity was also studied. Key words: C1018 steel, X-65 steel, wet gas, localized corrosion, stratified flow, cross section, surface analysis, pitting density, super-saturation, acetic acid, potentiodynamic sweeps

INTRODUCTION Natural gas does not emerge from the reservoir pure and is always accompanied by various amounts of water, carbon dioxide, hydrogen sulfide, and organic acids. These substances combine to give rise to a very aggressive environment where the survival of mild steel is not guaranteed. The multiphase mixture of gaseous and liquid hydrocarbons, water, CO 2 and H 2 S moves through the gas pipelines in a variety of complicated multi-phase flow patterns such as annular, slug and stratified flow, depending on the terrain topography and the individual phase flow rates. It is well known that flow can accelerate corrosion of mild steel by increasing the mass transfer rates of corrosive species and/or by damaging the protective films formed on the steel surface 1. In wet gas corrosion research, there are only a handful of studies that relate to field experience, some focusing on corrosion management 2 and control 3, others reporting actual case histories 4. In most studies the focus was on top-of-line corrosion 4-6 where high uniform corrosion and sometimes localized attack were associated with rapid condensation of water by external cooling. There are no studies reported in the open literature, which investigate the nature and magnitude of the attack in wet gas transport in the presence of low condensation rates, typical for well-insulated pipelines. Localized corrosion is not well understood even though some research has been done in this field. For example Xia et al. 7 studied pitting corrosion of carbon steel at room temperature and atmospheric pressure and suggested that galvanic couples were responsible for initiation and development of pits. Schmitt et al. 8-10 performed numerous experiments and concluded that the onset of localized attack was related to high near-wall levels of turbulence and the intrinsic growth stresses in the corrosion product scale. Nyborg 11 investigated initiation and growth of mesa attack and proposed a mechanism involving film breakdown. Actually, the common underlying theme in all these studies is that localized attack in CO 2 corrosion of mild steel is always associated with the formation and breakdown of protective iron carbonate films. However, it needs to be stressed that all these studies have been conducted in single-phase water flow. There are no studies on localized corrosion conducted under wet gas flow conditions. Hence, an extrapolation of these results achieved in single-phase flow to multiphase flows under field conditions is uncertain. Previous experiments in multiphase flow from this laboratory have been conducted at both high and low temperature. The low temperature (40 C) tests 12 concluded that localized corrosion does not occur in the absence of corrosion product film. The high temperature (90 C) tests covered the hydrodynamic effects of gas-water-oil flow 13, where even the presence of small amounts of oil was found to reduce the corrosion rate and prevent localized corrosion. Other parameters, such as the ph, pressure, and hydrodynamic effects, were also tested based on the recent parametric study from a mechanistic corrosion model 14. The present work focuses on the Cl - effect on localized CO 2 corrosion in stratified flow under natural condensation wet gas transportation conditions. Some understanding of the role of HAc in CO 2 corrosion comes from the field experience, as related to the so-called Top-of-Line-Corrorion 4. But, very few systematic studies have been performed in the laboratory. Little or no information exists about the fundamental effect of HAc on the anodic and cathodic reactions. Hedges and McVeigh 15 reported a mild increase in the cathodic reaction in the presence of HAc although their results were not fully conclusive. The work of Crolet et al. 16 suggests that the presence of HAc inhibits the anodic (iron dissolution) reaction. Garsany et al. 17 published workusing voltammetry to study the effect of acetate ions on the rates and mechanisms of corrosion using a rotating disc electrode (RDE) on film-free surfaces. The voltammograms show two waves, which they

attributed to hydrogen and acetic acid reduction on the steel surface. They argue that since acetic acid dissociation can occur very quickly it is not possible to distinguish the reduction of hydrogen ions from acetic acid at the electrode surface. Flow Loop and Test Section EXPERIMENTAL A unique, 18 m long, 10 cm diameter, high pressure, high temperature inclinable multiphase flow loop was used to study wet gas CO 2 corrosion. The entire loop is manufactured from 316L stainless steel. The test section has three pairs of ports at the top and the bottom, which are used to insert flushmounted electrical resistance (ER), linear polarization resistance (LPR), and weight loss (WL) probes for corrosion rate measurements. A detailed description of the flow loop and test section can be obtained elsewhere 13. Glass Cells A schematic of the test cell is shown in Figure 1. A three-electrode system was used with the counter electrode made of platinum and the reference connected to the cell by a Luggin capillary tube. A preconditioning cell was used to ensure a constant HAc concentration in the test cell. Since HAc is volatile, the preconditioning cell ensures that any gaseous HAc is in equilibrium with the flowing carbon dioxide and a constant concentration of HAc will be maintained in the test cell. The use of a gas bubbler downstream of the test cell ensures a positive pressure of carbon dioxide in the test cell. Specimen Preparation In the present study, two carbon steels (C1018 and X-65) are used for WL and cross-sectional analysis. The coupons are circular with a diameter of 11.6 mm and a thickness of 3.1 mm. The chemical compositions of the two steels are given in Tables 1 and 2. The specimens used in the glass cells were 5.4 cm 2 in area and the chemical composition is given in Table 3. Prior to testing, the specimen were polished by silicon carbide paper up to 600 grit, then rinsed with isopropyl alcohol, and air dried. The specimen for weight loss analysis were weighed and numbered and then introduced into the system immediately. The post-test cleaning procedure was performed by immediately rinsing the specimen with isopropyl alcohol, air drying, and then storaged for surface analysis at a later date. For WL analysis, the specimen were pickled in an inhibited 10% hydrochloric acid for removal of corrosion products, then neutralized in alkali, rinsed with distilled water and alcohol, air dried and weighed for mass loss measurements. After this, the specimen is examined under a Metallurgical Microscope (MM) for the localized attack measurements. For surface analysis specimens, after the surface of the specimen is examined by Scanning Electron Microscopy/Energy Dispersive Spectrum (SEM/EDS) and X-ray Diffraction (XRD), the specimens were prepared for the final step cross-sectional analysis, to examine the thickness and morphology of the corrosion product film. This is achieved by first embedding the coupon into epoxy, followed by cutting across the specimen surface. A MM and/or SEM was used to generate photographs of the cross section.

Operational Procedure for Flow Loop The experimental system is filled with a predetermined amount of a NaCl solution. The system is then deoxygenated by flushing carbon dioxide through the system until the level of dissolved oxygen is below 10 ppb. The system is then heated to the test temperature and pressurized to the test pressure. The flow rates of the gas and liquid were then set. Once the flow was stabilized, corrosion monitoring probes were then inserted into the flow loop. The test matrix for this work is shown in Table 4. The superficial liquid velocity (Vsl) of 0.1 m/s was used at superficial gas velocities (Vsg) of 10 m/s at a pressure of 4.45 bar and a temperature of 90 C. At this condition, the flow regime is in stratified flow according to the pressure drop measurement results shown in Figure 2. The ER probe is made from C1010, and LPR probe is made from C1018. Operational Procedure for Glass Cells To begin an experiment, the experimental apparatus was assembled, a salt solution was prepared and added to the cell, and then de-oxygenation occurred for one hour using carbon dioxide gas. The appropriate amount of HAc was then added to the cells and de-oxygenation occurred for an additional 30 minutes. The ph was monitored before and after the HAc addition to ensure the fluid composition was similar between test runs. The electrode was then immersed into the test solution and all electrical connections were made. The electrode s rotational velocity was set and allowed to rotate for approximately 30 additional minutes before any electrochemical measurements were carried out. The test matrix for the work is shown in Table 5. The potentiodynamic sweeps were conducted at a sweep rate of 0.2 mv/s and the solution resistance was measured using electrochemical impedance spectroscopy (EIS) and corrected for. The potentiodynamic sweeps were conducted at constant ph with the ph adjustment occurring after each sweep. During the anodic sweep for example, the system ph was set to 4.00 ± 0.01 and the sweep started. Due to iron dissolution, the ph of the system may rise to 4.08 by the end of the sweep. The ph was then adjusted using HCl before the beginning of the next sweep. Anodic sweeps were limited to polarization less than 200 mv above the corrosion potential to limit excessive iron concentrations in the test cell. The LPR measurements were taken at ±5 mv around the corrosion potential. Test with no NaCl in the Flow Loop RESULTS ON THE EFFECT OF Cl - In the test without Cl -, the ph and dissolved iron content increased with time as shown in Figure 2. The trend for both ferrous iron concentration and ph suggests that the rise of the ph was due to the corrosion (iron dissolution) process. The solution was under-saturated at the beginning of the test, but reached super saturation (SS) at the end, as indicated by Figure 3. Figure 4 shows the time evolution of uniform corrosion rate from ER and LPR measurements. In this particular test, the two techniques gave totally different results. For example, at the bottom of the pipe, the corrosion rate measured by ER remained high for the whole duration of the experiment, while the LPR showed a relatively high corrosion rate at the beginning, but a stabilized low corrosion rate at the end of the test, indicating the formation of a protective film. Two techniques showed the corrosion rate difference in two orders of magnitude.

The third technique, WL method was also used in the test. The integrated corrosion rates over the entire period of time are shown in Figure 5 for different methods. It is seen that WL method indicated high corrosion rates at the bottom for both materials, C1018 and X-65. The results from WL are in good agreement with that from ER. Thus the LPR results are considered to be at fault in this case. The specimen was visual examined first after the test and no localized attack was observed. However, microscopy inspections revealed that a highly spread non-uniform attack did occur on both materials, as shown in Figure 6. In fact, the hills and valleys, and sometimes mesa attack occupied the whole specimen surface. It is estimated that 50% of the surface area was covered by the grooves. The height distance between the hills and valleys is described as the magnitude of the localized corrosion rate in this paper, and the value is added in Figure 5 to the uniform corrosion rate. Test with 0.1% NaCl Similar to the test without NaCl, the ph and dissolved iron content increased during the test, as shown in Figure 7. The solution again started out as under-saturated and ended up being super saturated. Figure 8 shows the change of uniform corrosion rate with time measured by ER and LPR methods. At the beginning of the test, both ER and LPR bottom gave the same corrosion rate results. But after an initial period of time, LPR bottom showed a greatly decreased corrosion rate again and finally stabilized at a much lower value compared to the ER method, as reflected in the test without Cl -. The corrosion rate on the top, measured by the ER method, shows high corrosion at the beginning and then decreased to a relative stable and small value in a short time. Although the solution resistance was greatly decreased by adding NaCl, the top LPR measurements were still not stable. This probably suggests that the water on the top was predominantly from condensation. The corrosion rates have orders of magnitude difference between the bottom and top, reflected by all the three measurement techniques, as shown in Figure 9. Weight loss results are more comparable to ER results, while LPR deviates from the other two methods. However, there is a major difference in this test compared to the previous test with no NaCl. Some localized attack in the form of pitting or mesa corrosion was found on the bottom of the C1018 steel coupons (see Figure 10). X-65 was still attacked by non uniform corrosion and has the similar very rough surface as observed in the test without NaCl. The top specimen of both materials was well protected by thin films and no localized corrosion was found. This can be seen by cross-section analysis shown in Figure 10. Test with 1% NaCl. The results obtained in this test are shown in Figure 11, Figure 12, and Figure 13. This test was stopped after 100 hours due to the gas pump failure. But the experiment was long enough to show the trend and allow comparison with the previous two tests. For example, the ph and Fe 2+ concentration change obey the same trend as before (Figure 11), LPR bottom measurement again shows the protective film formation after an initial time (Figure 12). All the other corrosion rates measurements show the similar trend to the other two tests, but have slightly higher values (Figure 13). Localized corrosion occurred on both materials with a small percentage of surface area attacked, which is different from the last two tests. Cross-sectional analysis (Figure 14) again shows protective film on the top specimen and a very porous film on the bottom specimen.

DISCUSSION ON THE EFFECT OF Cl - Figure 15 shows the effect of NaCl concentration on the bottom corrosion rate from WL method for both materials. It is seen that Cl - has some effect on both uniform and localized corrosion rate on the bottom of the line. In all cases, localized corrosion occurred on both materials. However, this Figure cannot tell more about the nature of the localized attack. As described above, some of the localized attack was widespread on the specimen surface, with hills, valleys, and mesa typed corrosion covering the whole surface, while on others it was a true local phenomenon. Based on this consideration, pitting density is probably a more accurate concept to describe the localized corrosion. It is defined as the ratio of pitted area or the area suffering localized attack to the total area of specimen. The results are shown Figures 16 and 17. With an increase in Cl - concentration, the pitting density decreased, which means that the localized attack tends to be more local. C1018 and X65 seem to have different sensitivity with respect to Cl - concentration. In all the three experiments, the water chemistry was changing, from an under-saturated iron solution at the beginning to a very super-saturated iron solution at the end of each test. This might create a favorable environment for initiation of localized corrosion. Figure 17 may explain what happened. It seems that the super saturation point played a very important role in the onset to localized corrosion. Localized corrosion does not occur in either under-saturated solution or highly super-saturated solution. The tests presented in this work happened to fall in a range around the saturation line, and the localized corrosion was then triggered. Given the same environment parameters, the Cl - affects the solution super saturation level through ionic strength and solubility. Without exception, no localized corrosion was found on top of the line in any of the tests. The corrosion rate was orders of magnitude lower than the bottom, as shown in Figure 18 by ER measurement. Since the flow regime is in stratified flow, the water chemistry on the top of the line is different from the bottom. Under the flow conditions tested, the water on the top of the pipe could be from two sources: either from the droplets entrained in the gas phase, which should have the same chemistry as the water at the bottom; or from the pure condensing water, whose chemistry is very different. However, according to the cross-section images, the amount of water on the top must have been very small, enabling formation of a very thin film, which was rapidly saturated by FeCO 3 and lead to a protective layer. This layer was not affected by the presence of Cl -. Admittedly the concentration of Cl - at the top was most likely lower due to the presence of condensed water. Thus no localized corrosion was found on the top and the uniform corrosion rate remained low. Throughout the three experiments, ER and WL measurements were in good agreement, while LPR measurements deviated. The reason for this behavior could be the polarization, which disturbs the corrosion process. This would become more important when solution is around saturation point. Cathodic polarization consumes hydrogen ions and creates locally a higher ph, while the anodic scan releases more ferrous ion and increase the iron concentration on the steel surface. A higher ph and iron concentration could cause the high super saturation locally, which speeds up the film formation process. The surface analysis for the corroded specimen provides solid backing of the corrosion rate measurements. XRD results show that the corrosion product is mainly FeCO 3 (Figure 19). This is valid for both top and bottom specimen in all the three tests. The carbonate layer on the top seems more protective with smaller crystals, indicating higher super saturation and faster precipitation, than those formed on the bottom with more porous, less crystalline structure, as seen from Figure 20. The crosssections of the specimen (Figure 6, Figure 10, and Figure 14) show the thin, protective film on the top

and the thick, non-protective film on the bottom. The thickness of the top film is generally less than 10 µm, while the film formed on the bottom is more than 100 µm. In addition, at the bottom, the film is detached from the metal surface over large areas, which provided very poor resistance to corrosion. RESULTS AND DISCUSSION ON THE EFFECT OF HAc Initially, potentiodynamic sweeps were performed in 3% sodium chloride solution flushed with nitrogen for a concentration range of 0 to 1000 ppm HAc at ph 4. The ph was held constant to distinguish the effect of the acetic species on the cathodic and anodic reactions from the effect of H + (ph). At a constant ph, the concentration of hydrogen ions is fixed, and the effect of the acetic species on the cathodic and anodic reactions could be seen. The results are shown in Figure 21. There is a clear acceleration of the cathodic limiting current density with increased concentrations of HAc. The anodic reaction was inhibited with an increase in the HAc concentration, which has also been reported by Crolet 16. Since the cathodic charge transfer reaction did not move significantly with increasing concentrations of HAc, reduction of hydrogen ions is more likely occurring rather than direct reduction of HAc. The corrosion rates measured by LPR and Tafel analysis are shown in Figure 22. It should be stressed that the corrosion rates measured using LPR were taken within approximately 30-45 minutes of exposure to the test solution. The corrosion rates were estimated using a cathodic Tafel slope of 120 mv/dec and an anodic Tafel slope of 80 mv/dec. The corrosion rates estimated using these two methods are similar since the cathodic and anodic reactions are most likely under charge-transfer control for the hydrogen ion reaction. This is supported by the fact that the limiting current increased almost nine times (see Figure 21) while the corrosion current did not increase much. This indicates that acetic acid acts primarily as a source of hydrogen ions and does not affect the charge transfer reactions. This also has been reported by Garsany et al. 17 The effect of adding carbon dioxide was studied at the same concentrations of HAc. The results for the 0 ppm HAc concentrations are shown in Figure 23. It is evident from Figure 24 that the limiting current density of the cathodic reaction is increased slightly in the presence of carbon dioxide. The anodic reaction in nitrogen solutions was unaffected by an addition of carbon dioxide at all concentrations of HAc. The 100 and 1000 ppm HAc potentiodynamic sweeps are shown in Figure 24 and 25, respectively. At 100 ppm of HAc, the limiting current densities of the cathodic reactions for both solutions are significantly increased when compared to the 0 ppm HAc limiting current densities. Again a slight increase in the limiting current density of the cathodic reaction in the presence of carbon dioxide was found. A similar trend is found upon a further increase in the HAc concentration to 1000 ppm. The effect of HAc concentration was studied in 3% sodium chloride solutions adjusted to a ph of 4. The HAc concentration was varied from 0 to 5000-ppm and the cathodic and anodic sweeps are shown in Figures 26 and 27, respectively. As argued above, with increasing concentrations of HAc, the limiting current density of the cathodic reaction was accelerated. However, with increasing concentrations of HAc the anodic reaction was retarded. While not shown, the retardation in the anodic reaction was also evident in solutions containing nitrogen. The effect of HAc concentration on the CO 2 corrosion rate is shown in Figure 28. As before, the LPR measurements were taken within 30-45 minutes of electrode exposure to the test solution. As in cases where no CO 2 was present, the corrosion rates are approximately the same, regardless of HAc concentration, since the HAc is acting only as an extra source of hydrogen and the reactions are under

charge-transfer control so availability of hydrogen ions is not rate limiting. Selected potentiodynamic sweeps containing varying concentrations of HAc, which have already been shown in Figures 26 and 27, have been shown again in Figures 29 and 30, with the fitted Tafel slopes used in the LPR calculation. The effect of ph on the potentiodynamic sweeps was studied in 3% sodium chloride solutions containing 100 ppm HAc, adjusted in the ph range of 4 to 6. The results are shown in Figure 31. As the ph was increased from 4 to 5, the anodic reaction rate increased. But a further increase in ph from 5 to 6 does not result in a further increase in the anodic reaction rate. This has been seen in solutions with carbon dioxide in the past. According to Bokris 18, the hydroxyl molecule (OH - ) acts as a catalyst in the dissolution step for iron. At higher ph, the surface of the steel is saturated with the hydroxyl molecules and the rate-limiting step is the iron leaving the metal lattice. This saturation with hydroxyl molecules in carbon dioxide solutions occurs between a ph of four and five. The cathodic reaction however, is retarded by an increase in ph due to less hydrogen ions being available for reduction. The effect of velocity (500-4000 rpm) was studied using potentiodynamic sweeps performed in 3% sodium chloride solutions containing 100 ppm HAc and at ph 4. The results are shown in Figure 32. According to theory, the limiting currents should increase by a factor of 1.6 with each doubling of velocity since the Reynolds number term, in the Sherwood number correlation, is raised to the 0.7 power. The increase in the limiting current was measured to be approximately 1.8-2 when the velocity was doubled. The corrosion potential, as well as the anodic reaction, does not change with velocity suggesting a constant corrosion rate. This appears to support the assumption that the corrosion rate under the conditions studied was charge transfer controlled. The effect of temperature on the potentiodynamic sweeps was studied in 3% sodium chloride solutions containing 100 ppm HAc. The results are shown in Figure 33. There is a clear acceleration of both the cathodic and anodic reaction rates with an increase in temperature. Also, with an increase in temperature, the corrosion potential is shifted to more negative values due to the anodic reaction rate increasing more than the cathodic one. The corrosion rates measured by LPR and calculated from Tafel slopes are shown in Figure 34 and the two methods are in good agreement. CONCLUSIONS Under the multiphase test conditions, localized corrosion occurred at the bottom of line on both C1018 and X65 materials but with different pitting densities. Pitting density is thus recommended to use when describing the localized corrosion behavior. Neither C1018 nor X-65 suffered localized attack at the top of line under stratified flow conditions. Cl - content is important in the onset of localized corrosion since it largely affects the ionic strength and thus super-saturation level of the solution. C1018 and X-65 steels showed somewhat different sensitivity to pitting density with respect to Cl - concentration. It has been shown that the corrosion rate of carbon steel in the presence of HAc is not significantly affected by the HAc at room temperature since the corrosion rate is dominated by charge transfer of the H + reduction reaction. HAc did not affect the charge transfer mechanism of the cathodic reaction but the limiting current density was strongly affected.

The anodic reaction was retarded with increasing HAc concentrations, but the mechanism remained the same. ACKNOWLEDGEMENTS The authors wish to thank the Institute for Corrosion and Multiphase Technology at Ohio University and its member companies for the financial support of this research. REFERENCES 1. S. Nesic, M. Nordsveen, R. Nyborg, and A. Stangeland, A Mechanistic Model for CO 2 Corrosion with Protective Iron Carbonate Films, Corrosion/2001, paper no. 01040, (Houston, TX: NACE International, 2001). 2. S.D. Kapusta, B.F.M. Pots, and R.A. Connell, Corrosion Management of Wet Gas Pipelines, Corrosion/99, paper no.45, (Houston, TX: NACE International, 1999). 3. Y.M. Gunaltun and A. Belghazi, Control of Top of Line Corrosion by Chemical Treatment, Corrosion/2001, paper no.33, (Houston, TX: NACE International, 2001). 4. Y.M. Gunaltun, D. Supriyatman, and J. Achmad, Top of Line Corrosion in Multiphase Gas Lines, A Case History, Corrosion/99, paper no.36, (Houston, TX: NACE International, 1999). 5. B.F.M. Pots and E.L.J.A Hendriksen, CO 2 Corrosion under Scaling Conditions- the Special Case of Top-Of-Line Corrosion in Wet Gas Pipelines, Corrosion/2000, paper no.31, (Houston, TX: NACE International, 2000). 6. Y.M. Gunaltun and T. Chevrot, Requirements for Inhibition of Localized Corrosion, Corrosion/99, paper no.6, (Houston, TX: NACE International, 1999). 7. Z. Xia, K.C. Chou, and Z. Szklarska-Smialowska, Pitting Corrosion of Carbon Steel in CO2- Containing NaCl Brine, Corrosion, 45(8), p.636,1989. 8. G. Schmitt, T.Gudde, and E. Strobel-Effertz, Fracture Mechanical Properties of CO2 Corrosion Product Scales and Their Relation to Localized Corrosion, Corrosion/96, paper no.9, ((Houston, TX: NACE International, 1996). 9. G. Schmitt and M. Mueller, Critical Wall Shear Stresses in CO2 Corrosion of Carbon Steel, Corrosion/99, paper no.44, ((Houston, TX: NACE International, 1999). 10. G. Schmitt and S. Feinen, Effect of Anions and Cations on The Pit Initiation in CO2 Corrosion of Iron and Steel, Corrosion/2000, paper no.1, (Houston, TX: NACE International, 2000). 11. R. Nyborg, Initiation and Growth of Mesa Corrosion Attack During CO2 Corrosion of Carbon Steel, Corrosion/98, paper no.48, (Houston, TX: NACE International, 1998). 12. Y-H Sun, T. Hong, and W. P. Jepson, Corrosion under Wet Gas Conditions, Corrosion/01, paper no.01034, (Houston, TX: NACE International, 2001). 13. Y-H Sun, T. Hong, and C. Bosch, CO2 Corrosion in Wet Gas Pipelines at Elevated Temperature, Corrosion/02, paper no.02281, (Houston, TX: NACE International, 2002). 14. S. Nesic, K-L. J. Lee, and V. Ruzic, A Mechanistic Model of Iron Carbonate Film Growth And The Effect on CO2 Corrosion of Mild Steel, Corrosion/2002, paper no.02237, (Houston, TX: NACE International, 2002). 15. Hedges, B, and McVeigh, L., The Role of Acetate in CO 2 Corrosion: The Double Whammy, CORROSION/1999, Paper No. 21, (Houston, TX: NACE International, 1999). 16. Crolet, J-L., Thevenot, N., and Dugstad, A., Role of Free Acetic Acid on the CO 2 Corrosion of Steels, CORROSION/1999, Paper No. 24, (Houston, TX: NACE International, 1999). 17. Garsany, Y., Pletcher, D., Hedges, B., The Role of Acetate in CO 2 Corrosion of Carbon Steel: Has the Chemistry Been Forgotten? CORROSION/2002, Paper No. 2273, (Denver, CO: NACE International, 2002).

18. Bokris, J. O M, Reddy, A.K.N, Modern Electrochemistry, New-York, Plenum Press, 1973. Table 1. Chemical Composition of Type C1018 Carbon Steel (wt.%) C Si P S Mn Al Fe 0.21 0.38 0.09 0.05 0.05 0.01 balance Table 2. Chemical Composition of 5LX65 Steel (wt.%) C Si P S Mn Nb V 0.07 0.24 0.014 0.011 1.26 0.033 0.04 Table 3. Chemical Composition of 5LX65 Used in RCE (wt%) Cr Mo S V Si C Fe Ni Mn P 0.011 0.103 0.004 0.055 0.240 0.150 Balance 0.020 1.340 0.011 Table 4. Test Matrix for the Flow Loop Experiments Liquid phase 0, 0.1%, 1% NaCl Total pressure 4.45 bar CO 2 partial pressure 3.75 bar Temperature 90 C Superficial gas velocity 10 m/s Superficial liquid velocity 0.1 m/s Material C1018, X65, and C1010 Measurement techniques ER, LPR, and WL

Table 5. Test Matrix for the Glass Cell Experiments Liquid Phase 3 % NaCl Gases used for De-oxygenation N 2 and CO 2 HAc Concentration 0 5000 ppm Temperature 22 C ph 4.00 Rotational Velocity 1000 rpm Material X65 Measurement Techniques LPR, EIS, Potentiodynamic Sweeps Table 6. Super-Saturation Table and Estimated Pitting Density At the beginning of test At the end of test Pitting density = NaCl, pitted area/total area % Measured Measured Super Measured Measured Super C1018 X-65 ph Fe 2+ saturation level ph Fe 2 saturation level 0.0 4.65 20 0.60 4.94 50 5.5 50% 50% 0.1 4.65 20 0.42 5.13 100 30.9 9% 50% 1.0 4.65 20 0.27 5.3 100 21.4 3% 5% Figure 1. Diagram of the Test Cell

5000 4000 dp/l=38.5 Pa/m 3000 Differential pressure/pa 2000 1000 0-1000 -2000-3000 -4000-5000 0 5 10 15 20 25 30 Time/s Figure 2. The Differential Pressure Drop at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar 100 Fe++ ph 5.5 5.4 80 5.3 Fe++ concentration/ppm 60 40 SS=0.6 SS=1.0 SS=5.5 5.2 5.1 5 4.9 4.8 ph 20 4.7 4.6 0 4.5 0 20 40 60 80 100 120 140 160 180 200 Time/hr Figure 3. The Change of ph and Fe 2+ with Time for 0.0% Cl - solution at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

100 10 ER bottom ER top LPR bottom LPR top Corrosion Rate/mm/yr 1 0.1 0.01 0.001 0 20 40 60 80 100 120 140 160 180 200 Time/hr Figure 4. The Change in Corrosion Rate with Time for 0.0% Cl - Solution at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar) 100 90 80 Localized CR Uniform CR Corrosion Rate/(mm/yr) 70 60 50 40 30 20 6.4 2.3 10 0 12.8 11.5 12.9 0.49 0.95 0.01 bottom top bottom top bottom top bottom top WL C1018 WL X65 ER C1010 LPR C1018 Figure 5. Average Corrosion Rate and Localized Corrosion Rate (LC) from Different Methods for the Experiment without Cl - at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

epoxy epoxy steel steel Figure 6. Cross Sections for 0.0% Cl - Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar). left: bottom C1018; right: bottom X-65 100 Fe++ ph 5.5 5.4 80 SS=30.9 5.3 Fe++ concentration/ppm 60 40 SS=0.42 SS=1.0 5.2 5.1 5 4.9 4.8 ph 20 4.7 4.6 0 4.5 0 20 40 60 80 100 120 140 160 180 200 Time/hr Figure 7. The Change of ph and Fe 2+ with Time for 0.1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

100 10 ER bottom ER top LPR bottom LPR top Corrosion Rate/(mm/yr) 1 0.1 0.01 0.001 0 20 40 60 80 100 120 140 160 180 200 Time/hr Figure 8. The Change of Corrosion Rate with Time for 0.1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar) 100 90 Localized CR uniform CR 80 70 Corrosion Rate/(mm/yr) 60 50 40 30 20 6.6 6.7 10 0 16.4 9.6 1.1 13.4 0.39 3.6 0.0044 bottom top bottom top bottom top bottom top WL C1018 WL X65 ER C1010 LPR C1018 Figure 9. Average and Localized Corrosion Rate (LC) from Different Methods for 0.1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

epoxy epoxy steel (a) steel (b) epoxy epoxy steel (c) steel (d) Figure 10. Cross Sections for 0.1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar). (a) top C1018; (b) top X-65; (c) bottom C1018; (d) bottom X-65 100 SS=21.4 Fe++ ph 5.5 5.4 80 5.3 Fe++ concentration/ppm 60 40 SS=1.0 5.2 5.1 5 4.9 4.8 ph 20 4.7 SS=0.27 4.6 0 4.5 0 20 40 60 80 100 120 140 160 180 200 Time/hr Figure 11. The Change of ph and Fe 2+ with Time for 1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

100 10 ER bottom ER top LPR bottom LPR top Corrosion Rate/(mm/yr) 1 0.1 0.01 0.001 0 20 40 60 80 100 120 140 160 180 200 Time/hr Figure 12. The Change of Corrosion Rate with Time for 1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar) 100 90 Localized CR Uniform CR 80 70 Corrosion Rate/(mm/yr) 60 50 40 30 5.8 26.5 20 10 0 30.2 2.2 25.2 1.4 Figure 13. Average and Localized Corrosion Rate (LC) from Different Methods for 1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar) 18.1 0.36 8.3 0.0016 bottom top bottom top bottom top bottom top WL C1018 WL X65 ER C1010 LPR C1018

epoxy epoxy steel steel (a) (b) epoxy epoxy steel (c) steel (d) Figure 14. Cross Sections for 1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar). (a) top C1018; (b) top X-65; (c) bottom ER C1010; (d) bottom X-65 100 90 80 Localized CR Uniform CR Corrosion Rate/(mm/yr) 70 60 50 40 30 20 10 0 5.8 26.5 6.6 6.4 6.7 2.3 30.2 25.2 12.8 11.5 16.4 9.6 C1018 X65 C1018 X65 C1018 X65 0% NaCl 0.1% NaCl 1% NaCl Figure 15. The Effect of NaCl Concentration on Bottom Corrosion for Different Materials from WL Method at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

100 C1018 X65 pitting density/ (%) 10 1 0.0001 0.001 0.01 0.1 1 Cl- concentration/(%) Figure 16. The Effect of Cl- Concentration on Localized Corrosion at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar) (note: 0.0001% Cl - concentration is used to approximate no Cl - condition to facilitate the graphical illustration). 100 90 80 saturation line C1018, begining C1018, end X65, begining X65, end pitted area/total area/(%) 70 60 50 40 30 20 10 0 0.1 1 10 100 Super-saturation level Figure 17. The Relationship Between the Super-Saturation Level and Pitting Density at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

100 90 bottom top 80 Corrosion Rate/(mm/yr) 70 60 50 40 30 20 10 0 12.9 13.4 Figure 18. The Effect of NaCl Concentration on the Average Corrosion Rate by ER Measurements at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar) 18.1 0.49 0.39 0.36 0% NaCl 0.1% NaCl 1% NaCl 100 90 FeCO3 80 70 60 Intensity 50 40 FeCO3 FeCO3 30 FeCO3 20 10 0 10 20 30 40 50 60 70 80 Bragg's angles/degree Figure 19. XRD Spectrum for Coupons at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar)

(a) (b) (c) (d) Figure 20. SEM Micrographs for 0.1% NaCl Solutions at Vsg=10 m/s, Vsl=0.1 m/s, T=90 C, and P=4.45 bar (P co2 =3.75 bar). (a) top C1018; (b) top X-65; (c) bottom C1018; (d) bottom X65 Potential / V vs Ag/AgCl -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0-1.1-1.2 0 ppm 1000 ppm 100 ppm 100 ppm 0 ppm HAc 1000 ppm -1.3 0.1 1 10 100 1000 Current Density / A/m 2 Figure 21. Potentiodynamic Sweeps for 0, 100, and 1000 ppm HAc in Bubbling N 2 Solutions (ph 4, 1000 rpm, 22 C)

Corrosion Rate / mm/yr 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0.0 Tafel Analysis LPR 0 100 1000 HAc Concentration / ppm Figure 22. Effect of HAc Concentration on the Corrosion Rate of X-65 Steel in Bubbling N 2 Solutions (ph 4, 1000 rpm, 22 C) Potential / V vs Ag/AgCl -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0-1.1-1.2-1.3 N 2 CO 2 0.1 1 10 100 1000 Current Density / A/m 2 N 2 CO 2 Figure 23. Comparison Between Potentiodynamic Sweeps for 0 ppm HAc in Bubbling CO 2 and N 2 Solutions (ph 4, 1000 rpm, 22 C)

Potential / V vs Ag/AgCl -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0-1.1-1.2-1.3 N 2 CO 2 N 2 CO 2 0.1 1 10 100 1000 Current Density / A/m 2 Figure 24. Comparison Between Potentiodynamic Sweeps for 100 ppm HAc in Bubbling CO 2 and N 2 Solutions (ph 4, 1000 rpm, 22 C) Potential / V vs Ag/AgCl -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0-1.1-1.2-1.3 N 2 CO 2 0.1 1 10 100 1000 Current Density / A/m 2 N 2 CO 2 Figure 25. Comparison Between Potentiodynamic Sweeps for 1000 ppm HAc in Bubbling CO 2 and N 2 Solutions (ph 4, 1000 rpm, 22 C)

-0.5-0.6 Potential / V vs Ag/AgCl -0.7-0.8-0.9-1.0-1.1 0 ppm 10 ppm 100 ppm 1000 ppm 5000 ppm -1.2-1.3 0.1 1 10 100 1000 Current Density / A/m 2 Figure 26. Cathodic Sweeps for 0 5000 ppm HAc in Bubbling CO 2 Solutions (ph 4, 1000 rpm, 22 C) -0.30-0.35 Potential / V vs Ag/AgCl -0.40-0.45-0.50-0.55-0.60-0.65-0.70 100 ppm 1000 ppm 5000 ppm 10 ppm 0 ppm 0.1 1 10 100 1000 Current Density / A/m 2 Figure 27. Anodic Sweeps for 0 5000 ppm HAc in Bubbling CO 2 Solutions (ph 4, 1000 rpm, 22 C)

Corrosion Rate / mm/yr 2.5 2.0 1.5 1.0 0.5 Tafel Analysis LPR 0.0 0 10 100 1000 5000 HAc Concentration / ppm Figure 28. Effect of HAc Concentration on the Corrosion Rate of X-65 Carbon Steel in Bubbling CO 2 Solutions (ph 4, 1000 rpm 22 C) -0.5-0.6 120 mv/dec Potential / V vs Ag/AgCl -0.7-0.8-0.9-1.0-1.1-1.2 0 ppm 100 ppm 1000 ppm -1.3 0.1 1 10 100 1000 Current Density / A/m 2 Figure 29. Cathodic Sweeps for Selected HAc Concentrations in Bubbling CO 2 Solutions With Tafel Slopes (22 C, ph 4, 1000 rpm)

-0.30-0.35 Potential / V vs Ag/AgCl -0.40-0.45-0.50-0.55-0.60-0.65 100 ppm 1000 ppm 40 mv/dec 0 ppm 80 mv/dec -0.70 0.1 1 10 100 1000 Current Density / A/m 2 Figure 30. Anodic Sweeps for Selected HAc Concentrations in Bubbling CO 2 Solutions With Tafel Slopes (22 C, ph 4, 1000 rpm) Potential / V vs Ag/AgCl -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0-1.1-1.2-1.3 ph 4 ph 6 ph 5 ph 5,6 0.1 1 10 100 1000 Current Density / A/m 2 Figure 31. Potentiodynamic Sweeps for 100 ppm HAc in Bubbling CO 2 Solutions at ph 4-6 (1000 rpm, 21 C)

Potential / V vs Ag/AgCl -0.3-0.4-0.5-0.6-0.7-0.8-0.9-1.0-1.1-1.2-1.3 500 rpm 1000 rpm 2000 rpm 4000 rpm 0.1 1 10 100 1000 Current Density / A/m 2 Figure 32. Potentiodynamic Sweeps of 100 ppm HAc in Bubbling CO 2 Solutions at Varying Velocities (ph 4, 21 C) -0.3-0.4-0.5 22 C 40 C 80 C Potential / V vs Ag/AgCl -0.6-0.7-0.8-0.9-1.0-1.1 22 C 40 C 80 C -1.2-1.3-1.4 0.1 1 10 100 1000 Current Density / A/m 2 Figure 33. Potentiodynamic Sweeps in Bubbling CO 2 Solutions Containing 100 ppm HAc At Varying Temperatures (ph 4, 1000 rpm)

Corrosion Rate / mm/yr 9 8 7 6 5 4 3 2 1 Tafel LPR 0 22 40 80 Temperature / C Figure 34. Effect of Temperature on the Corrosion Rate of X-65 Carbon Steel in Bubbling CO 2 Solutions Containing 100 ppm HAc (ph 4, 1000 rpm 22 C)