FILMTEC Membranes System Design: Introduction

Similar documents
FILMTEC Membranes. Case History. Retrofitting Hollow Fiber Elements with Spiral Wound RO Technology in Agragua, Spain

DOW Ultrafiltration. Case History. DOW Ultrafiltration Modules Protect Reverse Osmosis System from High Iron

DOW Ultrafiltration. Case History. DOW Ultrafiltration Membranes Offer Reliable, Economical Answer to High Solids

FILMTEC Membranes How FILMTEC Seawater Membranes Can Meet Your Need for High-Pressure Desalination Applications

FILMTEC Membranes How FilmTec s New High-Rejection, Low-Energy Seawater Element Can Reduce Your Desalination Costs

Lenntech. Tel Fax

FILMTEC Membranes. FILMTEC Membranes Reclaim Waste Water at 86% Recovery in Singapore. Case History

Dow Water Solutions. FILMTEC Membranes. Product Information Catalog

DOW Specialty Membrane XUS and XUS Reverse Osmosis Elements

FILMTEC Membranes. Tech Manual Excerpts. Principle of Reverse Osmosis. Figure 1: Overview of Osmosis / Reverse Osmosis

Lenntech. Tel Fax

Location: Purpose: Time in Operation: Performance:

Membrane Technology: From Manufacture to. May Production

REQUEST FOR PROPOSALS DESAL ANTISCALANT/CLEAN-IN-PLACE CHEMICALS BID NO: ADDENDUM 1

Membrane Protection Resins Ion Exchange Resins and Reverse Osmosis in Partnership

DOWEX Ion Exchange Resins

Saving Energy and Water. Working with High Recovery Water Treatment Plants

Lenntech. Tel Fax DOW FILMTEC Membranes. Tech Fact

RO System Design & CSMPRO v6.0 Program

Reverse Osmosis. Background to Market and Technology

ACUMER ACUMER 4450 ACUMER 4800

Brackish Ground Water Desalination: Challenges to Inland Desalination Technologies (It sure ain t seawater desalination)

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources

FILMTEC Membrane Element Analysis

Dow Water & Process Solutions. FILMTEC Reverse Osmosis Membranes. Technical Manual

TECHNICAL NOTE Permeate recovery and flux maximization in semibatch reverse osmosis

MEMBRANE CHEMICALS Presented by: Majid Karami

Troubleshooting Performance Issues of Reverse Osmosis Systems. Justyna Warczok TS&D

Dow Liquid Separations. FILMTEC Elements. An Overview of Products, Applications, and Technical Resources

Case History. Solves Leakage Problems and Improves Energy Efficiency in Semiconductor Plant

FOSSIL POWER PLANT WATER TREATMENT. Generating optimal performance, powered by Dow.

Technical Presentation RO Basics. MWQA October Bill Loyd Technical Services & Development Dow Water & Process Solutions

Solutions Industry pioneers in spiral membrane technology

performance of the ultrapure make-up system at Turkey Point Nuclear Power Plant

SEAMAXX. The Low-Energy Solution. The Seawater Reverse Osmosis membrane with the highest permeability in the industry. Dow.com

III III III III ROfine

1. The Antiscalant, and/or CIP chemicals where specified, provided under this contract shall meet the following specifications:

The evolution of high purity water production

Job Name Job Location. I. Is Hydrogen Sulfide (H2S) present? Yes No If yes, what is the concentration level?. Yes No

Operation of Hydranautics New ESNA Membrane at St. Lucie West, FL Softening Plant

1. Inspection and monitoring... 3

DESIGN AND OPERATION OF A HYBRID RO SYSTEM USING ENERGY SAVING MEMBRANES AND ENERGY RECOVERY TO TREAT SOUTHERN CALIFORNIA GROUND WATER.

Reuse of Refinery Treated Wastewater in Cooling Towers

Water Treatment and Conveyance System Salem Gammoh, Jordan Ministry of Water and Irrigation

Reverse Osmosis and Nano-filtration Innovation for Water Re-use

Treating Heavy Oil Wastewater for Beneficial Use by Integrated Technology of Bio-Oxidation and RO

THE ECONOMICS OF SEAWATER REVERSE OSMOSIS DESALINATION PROJECTS. Abstract

Bay Water SWRO Desalination: Challenges and Solutions

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

Membrane Desalination Systems

Key words: Integrated Membrane System, IMS, Seawater Reverse Osmosis, SWRO, SW30HRLE- 400, Ultrafiltration, UF, ZeeWeed 1000

Novel Low Fouling Nanofiltration Membranes. Craig Bartels, PhD, Hydranautics, Oceanside, CA Warren Casey, PE, Hydranautics, Houston, TX

Overview of Desalination Techniques

Feasibility of Nanofiltration process in dual stage in desalination of the seawater

Use of Spiral Wound UF in RO Pretreatment

Summary of Pilot Plant Results and Preliminary Recommendations

OsmoBC Integrated Membrane Systems

FEDI. Fractional Electrodeionization. The evolution of high purity water production

Design Parameters Affecting Performance

Producing High-Purity Recycled Water for Industrial Applications with Microfiltration and Reverse Osmosis: Lessons Learned

Seawater desalination with Lewabrane LPT, 2016

Process Development and Application of Membrane Technology

Dow Water Process Solutions Filmtec Reverse Osmosis Membranes Technical Manual

Date Job Name Job Location. I. Is Hydrogen Sulfide (H2S) present? Yes No If yes, what is the concentration level?.

Water Reuse/Recycle. Can this be Performed Economically in Today s Mills

Engineering & Equipment Division

Reduction of fresh water intake by desalination. Raymond Creusen (TNO)

Treated Effluent (TSE) Reuse Applications and Challenges. Saudi Arabia

electrodialysis treatment of surface and waste waters

Peculiar or unexpected behavior of Silt Density Index of pretreated seawater for RO desalination

Texas Desal 2017 NEXED EDR Technology Demonstration 22nd September Evoqua Water Technologies LLC

Water Treatment Technology

Hybrid RO & Softening Birjand Water Treatment Plant

Design and Local Manufacturing of Energy Efficient High Pressure Pumps for Small SWRO Units Amr A. Abdel Fatah

PRETREATMENT FOR SEAWATER REVERSE OSMOSIS DESALINATION PLANTS

IMPROVING PERFORMANCE AND ECONOMICS OF RO SEAWATER DESALTING USING CAPILLARY MEMBRANE PRETREATMENT

Reclaimed Waste Water for Power Plant Cooling Tower Water & Boiler Feed Make-up. Richard Coniglio, Business Product Manager

PRESENTATION OF DESALINATION VIA REVERSE OSMOSIS

Reverse Osmosis Elements Product Manual

DOWEX UPCORE Ion Exchange Resins Retrofit of Demineralizer with UPCORE System Cuts Chemical Costs by 50%

Commercial Reverse Osmosis System

'HR' SERIES INDUSTRIAL HIGH REJECTION SYSTEMS

Using a Novel Hybrid NF-RO to Enhance Sodium Chloride Removal

New Generation of Low Fouling Nanofiltration Membranes

TECHNICAL MANUAL. EKO Srl Via Caduti del Lavoro, Borgo Val di Taro (Parma) - Italy Technical Manual n.

--... _ 2-- I I J: 3 4 /

OPTIDOSE 4210 Traceable Polymeric Acid Scale Inhibitor and Dispersant

PRODUCTS & APPLICATIONS COURSE WATER TREATMENT PRESENTATION John Waema

LOW FOULING REVERSE OSMOSIS MEMBRANES: EVIDENCE TO THE CONTRARY ON MICROFILTERED SECONDARY EFFLUENT

Beer Filtration Solutions Your Partner for All Your Filtration Needs

AL-KAWTHER INDUSTRIES LTD

Effluent Treatment Methods And Reverse Osmosis and its Rejects Handling

Large Diameter Seawater Reverse Osmosis Elements A Year s Operation in Chile

Brad Herbert, ON Semiconductor. Alan Knapp, Siemens Industry, Inc. Water Technologies. Wayne Bates, Hydranautics. John Morgan, H2Morgan LLC

Lenntech. Dow Liquid Separations. DOWEX Ion Exchange Resins. The Advantages of Uniform Particle Sized Ion Exchange Resins.

Protegra CS RO Series. Meeting All Your Pure Water Demands. Water Technologies

You get more for less at FSHS!

Direct count methods should be preferred, because they are much faster and more accurate than culture techniques.

THE CURRENT USE OF HOLLOW FIBRE ULTRAFILTRATION AS PRE-TREATMENT FOR REVERSE OSMOSIS

Summary of Issues Strategies Benefits & Costs Key Uncertainties Additional Resources

Transcription:

Tech Manual Excerpt FILMTEC Membranes System Design: Introduction Introduction An entire reverse osmosis (RO)/nanofiltration (NF) water treatment system consists of the pretreatment section, the membrane element section, and the post-treatment section. Pretreatment techniques are discussed in Water Chemistry and Pretreatment (Section 2). Post-treatment is employed to achieve the required product quality. In seawater desalination, this is usually ph adjustment, rehardening and disinfection. In ultrapure water (UPW) production, the permeate is usually post-treated by polishing ion exchange demineralization. In this section, the membrane system is addressed. The system includes a set of membrane elements, housed in pressure vessels that are arranged in a certain manner. A highpressure pump is used to feed the pressure vessels. Instrumentation, spare parts and tools for services are added as required. A clean-in-place (CIP) system facilitates cleaning of the membranes. This is described in Cleaning and Sanitization (Section 6). The membrane system is a complete plant with an inlet for feed water and outlets for permeate and concentrate. RO/NF system performance is typically characterized by two parameters, permeate (or product) flow and permeate quality. These parameters should always be referenced to a given feed water analysis, feed pressure and recovery. The goal of the designer of an RO/NF system for a certain required permeate flow is to minimize feed pressure and membrane costs while maximizing permeate quality and recovery. The optimum design depends on the relative importance of these aspects. The recovery of brackish water systems is limited by the solubility of sparingly soluble salts (see Scaling Calculations, Section 2.4) -- 90% is about the maximum. In seawater desalination, the limit of about 50% recovery is dictated by the osmotic pressure of the concentrate stream, which approaches the physical pressure limit of the FILMTEC seawater element. Obtaining the requested salt rejection is mainly a matter of membrane selection. The NF (NF270 > NF200 > NF90), brackish water (BW) (extra low energy (XLE) > BW30LE > BW30), SW (seawater), and SWHR (seawater high rejection) versions of the FILMTEC NF and RO membrane have higher salt rejections in this order, but they also need higher feed pressures under the same conditions. Therefore, the NF to BW30LE membrane is typically applied to feed waters up to 2,000 mg/l total dissolved solids (TDS), BW30 up to 10,000 mg/l, and SW and SWHR to high salinity feed waters up to 50,000 mg/l. For given operating conditions, the permeate quality can be calculated. The feed pressure needed to produce the required permeate flow for a given membrane depends on the designed permeate flux (permeate flow rate per unit membrane area). The higher the permeate flow per unit of active membrane area, the higher the feed pressure. In seawater systems the permeate flux is relatively low even at maximum allowed pressure. However, the permeate flux could be very high in brackish water systems without reaching the limit of 600 psi (41 bar) for brackish water elements. Although it is tempting to increase the permeate flux to minimize the costs for membrane elements, the flux has to be limited to minimize fouling. Page 1 of 5 Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 609-02046-1004

Introduction (cont.) From experience, the flux limit to be used in system design depends on the fouling tendency of the feed water. A system designed with high permeate flux rates is likely to experience higher fouling rates and more frequent chemical cleaning. Only experience can set the limits on permeate flux for different types of waters. When designing a membrane system for a specific feed water, it is advantageous to know the performance of other membrane systems operating on the same water. However, quite often there are no other membrane systems for comparison. Then the system design suggestions in Design Guidelines for 8- inch (Section 3.9.1) and Midsize FILMTEC elements (Section 3.9.2) could be followed. Further information required to design a system is best collected by using the forms of Table 3.1 and Table 3.2 below. The more complete this information, the better the system design can be optimized towards the customer s needs. Page 2 of 5 Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 609-02046-1004

Table 3.1 System design information Quotation Number:... Date Requested:... Date Submitted:... Requested By:... Customer/OEM:... Address:... Proposed Location:... Brief Description:... Required Product Flow Rate (gpd or m 3 /h):... Expected Recovery:... Annual Water Temperature Range High C:... Low C:... Design C:... NF/RO Plant: Indoors Outdoors Designed for Continuous Use: Yes No If not, state needed peak hourly capacity:... Plant Will Be Operated By: Enduser Yes No Trained Personnel Yes No Equipment Manufacturer Yes No Others Yes No Water Source: Well Water Softened water Surface Water Filtered Effluent Water Sea Water Other Existing Pretreatment Yes No SDI... List of Pretreatment Steps:... Planned Pretreatment:... Bacterial Control: Yes No Dechlorination: Ac-Filter Chlorine Used Yes No Na-Bisulfite Chloramines Used: Yes No Other Antiscalant Used: Yes No Which One?... Desired Acidification: HCl H 2 SO 4 None Brief Description of Other Pretreatment Steps:... (e.g., clarification, flocculation, multimedia/sand filtration, etc... Application: Potable Water Industrial Supply for: Boiler Feed Pharma Electronics Other Specify Water Quality Needed after RO Treatment:... State Other Desired Design Criteria:... Page 3 of 5 Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 609-02046-1004

Table 3.2 Water analysis for reverse osmosis/nanofiltration Sample identification:... Feed source:... Conductivity:... ph:... Temperature ( C):... Feed water analysis: + NH 4... CO 2... Please indicate units (mg/l as ion K +... 2 CO 3... or ppm as CaCO 3 or meq/l) Na +... HCO 3... Mg 2+... NO 3... Ca 2+... Cl... Ba 2+... F... Sr 2+... 2 SO 4... Fe 2+... 2 PO 4... Fe (tot)... S 2... Mn 2+... SiO 2 (colloidal)... Boron... SiO 2 (soluble)... Al 3+... Other ions:... TDS (by method):... TOC:... BOD:... COD:... AOC... BDOC... Total alkalinity (m-value):... Carbonate alkalinity (p-value):... Total hardness:... Turbidity (NTU):... Silt density index (SDI):... Bacteria (count/ml):... Free chlorine:... Remarks:... (odor, smell, color, biological activity, etc.)......... Analysis by:... Date:... Page 4 of 5 Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 609-02046-1004

FILMTEC Membranes For more information about FILMTEC membranes, call the Dow Water Solutions business: North America: 1-800-447-4369 Latin America: (+55) 11-5188-9222 Europe: (+32) 3-450-2240 Pacific: +60 3 7958 3392 Japan: +813 5460 2100 China: +86 21 2301 9000 http://www.filmtec.com Notice: The use of this product in and of itself does not necessarily guarantee the removal of cysts and pathogens from water. Effective cyst and pathogen reduction is dependent on the complete system design and on the operation and maintenance of the system. Notice: No freedom from any patent owned by Seller or others is to be inferred. Because use conditions and applicable laws may differ from one location to another and may change with time, Customer is responsible for determining whether products and the information in this document are appropriate for Customer s use and for ensuring that Customer s workplace and disposal practices are in compliance with applicable laws and other governmental enactments. Seller assumes no obligation or liability for the information in this document. NO WARRANTIES ARE GIVEN; ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ARE EXPRESSLY EXCLUDED. Page 5 of 5 Trademark of The Dow Chemical Company ( Dow ) or an affiliated company of Dow Form No. 609-02046-1004