Heat Value Gas Chromatograph ISO standard version

Similar documents
MicroSAM / Sitrans CV

Waarom moeilijk doen als het makkelijk(er) kan

FGA 300 Panametrics Flue Gas Oxygen Analyzer. GE Sensing. Features. Applications

AT9000 Advanced Transmitter Absolute Pressure Transmitters

WI/CV Multiparameter Gas Analyzer System SG12WMTA-Series

LEADERS IN PROCESS ANALYSIS AND CONTROL. Safety Solu ons. for Industrial Facili es

Turnkey configurations for gas chromatographic analysis, including instrumentation, methods, supplies and service. Analysis of Natural Gas

APPLICATION NOTE. Real- time inline process monitoring. Refinery, fuel gas V

Expanding the Versatility of Micro GC in the Shale Gas Play; The Agilent 490 Micro GC offers unprecedented reliability and flexibility

AT9000 Advanced Transmitter Absolute Pressure Transmitters

SAFETY PROCESS INDUSTRY LABORATORY & RESEARCH

AT9000 Advanced Transmitter Gauge Pressure Transmitters

8 stream capability with dual mode (H 2 S & total Sulphur)

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

Large Valve Oven Analyzers for Refinery Gas Analysis. ASTS 2015 Houston Shannon Coleman Application Specialist Agilent Technologies

Using a Micro GC to measure, monitor, and optimize your process. ASTS, Houston June 2015 Shannon Coleman Agilent Technologies

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

MIDSTREAM GAS QUALITY

Prima PRO process mass spectrometer

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

VLM10 In-line Vortex Mass Flow Meter

EuroFID Total Hydrocarbon Analyzer

Improving Natural Gas Liquefaction Plant Performance with Process Analyzers

Road Tunnel Atmosphere Monitoring Systems TunnelCraft 3 - Air Quality Monitor Continuous measurement of NO2 and Visibility in road tunnels

SG06UNINC-Series BGA/IP55/P Series in Outdoor Designed

Hydrocarbon Processing Industry Gas Chromatographs. Standard GC Analyzer Solutions

ADVANCES IN MICRO GAS CHROMATOGRAPHY

ETHYLENE PLANT DRY CRACKED GAS Product Code 54801

Paper TO7-2 DEVELOPMENT OF REAL-TIME GAS QUALITY MEASUREMENT

FLUIDISTOR GAS FLOWMETER GD 100 (EX)

X-STREAM X2XF - Field Housing Gas Analyzer

Meet the airgc. Ambient air carrier. Top performance. catalytics accelerated

OPTIMASS 7400 Technical Datasheet

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

OXITEC Oxygen Analyser Systems. Maximum Efficiency and Supreme Quality for the World Market ENOTEC

Use of Process Analytics in Cryogenic Air Separation Plants

ST3000 Series 900 Smart Transmitter Remote-sealed type of Differential Pressure Transmitters

ADVANCES IN MICRO GAS CHROMATOGRAPHY

X-Change Gas Sensor Cartridges. PolyGard 2 SC2

Pressure Transmitter STK136,STK136Q

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

For highest levels of purity

Carbon / Hydrogen / Sulfur Analyzers

KANE455 Infra-Red Analyser

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

OptiPEAK TDL600 Moisture in Natural Gas Analyzer

Tuffy II Liquid Level Controls with Electric Switches

GC8000 Process Gas Chromatograph. Bulletin 11B08A01-01E

PROCESS. Process Analysers For Gas and Liquid Phase

ADVANCES IN MICRO GAS CHROMATOGRAPHY

SERIES 60 DETECTORS-TRANSMITTERS FOR FLAMMABLE, TOXIC GASES AND OXYGEN ATEX. Your environment, your safety, let s master them together

Complexity. C9+, H2S, methanol, wet gas. Fiscal / Custody transfer. Simpler installation /operation

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

Biogas analysers. Product overview. MRU over 30 years of innovative gas analysis! Biogas, landfill gas, biomethane, coal mine gas, CHP exhaust gas

Features. Measurement range :0-10ppm or 0-500ppm. Large touch panel display for easy operation in the field. Standard Specifications

COST-EFFECTIVE GAS COMPOSITION SENSOR LNG3 Workshop - Aberdeen, 25 October 2018 Huib Blokland, Arjen Boersma

X-STREAM Enhanced XEXF - Field Housing Gas Analyzer

Agilent 490 Micro GC Biogas Analyzers

Agilent Gas Phase Solutions

Online data sheet MAC800 CUSTOMIZED ANALYZER SYSTEMS

HILASE - QUALITY CONTROL INSTRUMENT

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Q & A on Moisture in Transformer Oil

OPTIMASS 7400 Technical Datasheet

Mach-RGA. The Fast Refinery Gas Analyzer. Analyzer

UV300 LINE WATER ANALYSER TETHYS INSTRUMENTS 57, CHEMIN DU VIEUX CHÊNE, MEYLAN -FRANCE-

Liquid level switch BW 17

Flow measurement of Liquids and Gases

Aurora Moisture Analyzer New Light for Moisture Measurement in Carbon Dioxide

Analysis of Permanent Gases and Extended Hydrocarbons in Natural Gas and Natural Gas Liquids by Capillary Gas Chromatography

REPORT. Hobré HIGAS, a Portable Natural Gas Quality Meter. Wobbe Index Analyzer. Project report September 2015

Development of an LNG sampling and composition measurement reference standard. Jianrong Li LNG II Workshop 22 August 2017, VSL, Delft, NL

Natural Gas Monitoring

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Micro Motion LNG Series Meters

Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas

Biogas Upgrading and Bottling Technology Developed for Vehicular Applications

CEM500-L. Online Gas Analyser. Specialist Of UV Spectroscopy

Low-Emission Gland Packing System

IOHN Workshop Sum Up. DNV Høvik 15 August Ron Montgomery, IBM Ellen Sjølie, DNV Magne Valen-Sendstad, DNV

Calibration gas cylinders Calibration gas cylinders for the calibration or the periodical checkings of the gas detectors

Bulk Calculations - Gas BCG 3.0. Supported Standards Manual. Lists the standards supported by BCG 3.0 at the time of document publication

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

X-STREAM Flameproof Gas Analyzers

DR1000 Flying Laboratory, Drone Environmental Monitoring

Excellence in gas analyzers since Over 186 years of Jobin Yvon optical experience. The expertise of HORIBA combustion technology

EXM500. Online Gas Analyser. Specialist Of UV Spectroscopy

AT9000 Advanced Transmitter Gauge Pressure Transmitters

Online Infrared Flue Gas Analyzer Gasboard 3000

Agilent 490 Micro GC. The Measure Anywhere Micro GC February 2011

Tuffy II Liquid Level Controls with Electric Switches

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Fast Analysis of Extended Natural Gas using the New Transportable INFICON Micro GC Fusion

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

Red Eye Multiphase Water-Cut Meter

Fast Refinery Gas Analysis Using the Agilent 490 Micro GC QUAD

FLUXUS G. Non-Invasive Gas Flow Measurement. External Measurement of Internal Flow. Natural Gas Extraction. Offshore. Gas Transmission.

Compact body packed with abundant functions Fuji infrared gas analyzer

Transcription:

No. SS2-HGC303-0100 OVERVIEW Heat Value Gas Chromatograph ISO standard version The model HGC303 is the world smallest gas chromatograph, which is capable of analyzing 11 different components of natural gas and digitally publishing the derived parameters, such as calorific value, Wobbe-index, or density. By using our leading sensing & control technology, we designed the model HGC303 specifically for custody transfer, quality control, and other natural gas applications to meet the demands of the expanding natural gas market. The model HGC303's size, weight, cost and other great features gives the user the benefits of functionality, flexibility and economy from the production site to the pipe line station to the gas distributor and onto the end user's station. Model HGC303 FEATURES Small size for easy field installation The model HGC303 has a compact design thus facilitating field installation. In addition, the device can be mounted with a sampling system in the field. Small compact packaging No analyzer house is required Flameproof certified Pre-engineered analysis and calculations for Natural Gas Metering The model HGC303 has pre-engineered analysis and calculations for Natural Gas Metering so that no additional programming or application work is required. Easy to set up straight out of the box Analysis of 11 components and pre-configured value calculations Analysis and calculations based on international standards Digital communication for system integration The model HGC303 is capable of supporting MODBUS protocols with optional analog output capabilities and has been tested with leading flow computers. PC monitoring and online diagnostics The Heat Value Gas Chromatograph Monitor (HGM) is a PC-based software that allows the user to view all data and diagnostic information from a laptop computer. ADVANTAGES Simple to start-up and easy to maintain A huge amount of time and cost in the analyzer system start up phase can be saved with the model HGC303 s unique packaging and preengineered functions. The unit s easy-to-maintain design contributes to time and cost savings and it can be repaired without the need for analyzer expertise. Specifications are subject to change without notice. - 1 -

No. SS2-HGC303-0100 FUNCTIONAL SPECIFICATIONS Principle of measurement Gas chromatography Measured gas streams 1 Analyzed components 11 Analysis time 300 sec. Detector Micro TCD (Thermal Conductivity Detector) Chromatographic method ISO 6974, part 4 Heat value calculation method ISO 6976 Gas to be analyzed Natural gas Component measuring ranges and minimum detection Components Ranges (mol%) Sum of C6+ 0-0.3 0.01 C3H8 (propane) 0-3 0.05 i-c4h10 (i-butane) 0-1 0.01 n-c4h10 (n-butane) 0-1 0.01 neo-c5h12 0-0.5 0.01 (neo-pentane) i-c5h12 (i-pentane) 0-0.5 0.01 n-c5h12 (n-pentane) 0-0.5 0.01 N2 (nitrogen) 0-20 0.1 CH4 (methane) 50-100 - CO2 (carbon dioxide) 0-10 0.05 C2H6 (ethane) 0-15 0.05 Minimum detection (mol%) Analyzer outputs Yamatake Corporation PV1 C6+ (sum of C6+)(mol%) PV2 C3H8 (propane)(mol%) PV3 i-c4h10 (i-butane)(mol%) PV4 n-c4h10 (n-butane)(mol%) PV5 neo-c5h12 (neo-pentane)(mol%) PV6 i-c5h12 (i-pentane)(mol%) PV7 n-c5h12 (n-pentane)(mol%) PV8 N2 (nitrogen)(mol%) PV9 CH4 (methane)(mol%) PV10 CO2 (carbon dioxide)(mol%) PV11 C2H6 (ethane)(mol%) PV12 SCV (real) (MJ/m 3 ) [default], (kj/m 3 ), (kwh/m 3 ) or SCV (ideal) (MJ/m 3 ), (kj/m 3 ), (kwh/m 3 ) or ICV (real) (MJ/m 3 ), (kj/m 3 ), (kwh/m 3 ) or ICV (ideal) (MJ/m 3 ), (kj/m 3 ), (kwh/m 3 ) PV13 Density (real) (kg/m 3 ) [default] or Density (ideal) (kg/m 3 ) or Relative density (real) or Relative density (ideal) PV14 Wobbe index (real) (MJ/m 3 ) [default], (kj/m 3 ), (kwh/m 3 ) or Wobbe index (ideal) (MJ/m 3 ), (kj/m 3 ), (kwh/m 3 ) PV15 Compressibility factor Zmix PV16 Total of raw concentrations(mol%) PV17 Oven temperature(degree C) PV18 Carrier gas pressure(kpa) PV19 ICV (real) (MJ/m 3 ) [default], (kj/m 3 ), (kwh/m 3 ) or ICV (ideal) (MJ/m 3 ), (kj/m 3 ), (kwh/m 3 ) PV20 Relative density (real) [default], Relative density (ideal) or Helium normalized conc. (mol%) Auto-calibration External solenoid valve and HDM contact are required. Normalization of concentrations On-line diagnostics Hazardous area certification ISSeP/ATEX certifications: II 2 GD EEx d IIC T6 IP65-2 -

Yamatake Corporation No. SS2-HGC303-0100 Process Gas Temperature -10 C to 50 C Flow rate 50 ± 20ml/min Dust and mist None Moisture Less than 2000 ppm Coexisting components limit H2 < 0.1 mol% He < 0.1 mol% Oxygen < 0.1 mol% H2S (dry) < 0.1 mol% Ambient temperature limits -10 C to 50 C -40 C to 70 C for storage and transportation Ambient humidity Range 0-95%RH CE marking Electromagnetic compatibility (EMC):2004/108/EC Equipment explosive atmospheres (ATEX): 94/9/EC PERFORMANCE SPECIFICATIONS Repeatability of analysis ± 0.05% CV PHYSICAL SPECIFICATIONS Color Metallic light green, silver Material Body Cast aluminum Oven Cast aluminum Wet-parts 304 Stainless steel, polyimide Sensor Pt, glass, gold Dimensions W: 100 mm D: 115 mm H: 244 mm Weight 3.5kg - 3 -

No. SS2-HGC303-0100 Yamatake Corporation COMMUNICATIONS The model HGC303 communicates to a PC for configuration, maintenance and data transmission. PC and HGC bus connections are provided as standard equipment. A specific Windows-based model HGC303 software, the HGC Monitor HGM, enables convenient model HGC303 instrument control in a user-friendly environment. Retransmission of data to the central system can be performed via the Internet. Modbus communication is also available for networking with, for example, a flow computer or SCADA system. INSTALLATION Mounting Vertical 2 in. pipe mount Power supply 24V DC ± 15% 4A min Power consumption 5~50VA at -10 C to 50 C Utilities Carrier gas: Helium Purity 99.99% or higher Pressure 400 kpa ± 50 kpa Consumption 25ml/min (approximately) Instrument air (for actuating the valve) Pressure 400 kpa ± 50 kpa Environmental classification Sheltered location (protected from sunlight or precipitation) - 4 -

Yamatake Corporation No. SS2-HGC303-0100 MODEL SELECTION Heat Value Gas Chromatograph HGC303 - I II Basic Model No. HGC303- I Conduit entry 1/2 NPT 1 Gas connection 1/4 NPT II Explosion-protection ISSeP/ATEX Flameproof E DIMENSIONS [Unit: mm] - 5 -

Note

Note

Advanced Automation Company 1-12-2 Kawana, Fujisawa-shi Kanagawa-ken 251-8522 Japan URL:http://www.azbil.com No part of this publication may be reproduced or duplicated without the prior written permission of Yamatake Corporation. Mar. 2009 _ Y/Y