Marysville School District Resource Conservation Program. John Bingham Marysville S.D. Ray Burton Snohomish Co. P.U.D.

Similar documents
Lake Oswego School District 7J

Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

Energy Benchmarking Report for Mt. Pleasant Elementary School. Millville, NJ

Beaverton School District

SCHOOL ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

Resource Conservation Management Program

9/13/2011. Mark Hanicits, Director of Facilities and Safety, MetroSouth Medical Center. Terry Malloy P.E., Cxa, Project Manager, Teng & Associates

LIBRARY ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

Raymore-Peculiar Schools. Energy Management Program Guidelines

No Cost/Low Cost Energy

Normal Children's Discovery Museum, LEED Silver:

BEYOND O&M. Shawn Maurer SEDAC Building Energy Specialist. Smart Energy Design Assistance Center (SEDAC), University of Illinois at Urbana Champaign

Energy Benchmarking Report for Mill Pond Elementary School Lanoka Harbor, NJ

SECTION 900: BUILDING AND SITES

Energy Benchmarking Report for Bacon Elementary School. Millville, NJ

Energy Benchmarking Report for Forked River Elementary School Forked River, NJ

BB&E GREENHOUSE GAS EMISSIONS INVENTORY. Prepared For: General Services Administration (GSA) Joint Base Andrews, Maryland.

Energy and Utility Management Plan and Procedures. Updated September 7, 2018 by: Danny Helm Energy Manager

Energy Benchmarking Report for LaMonte Annex Elementary School Bound Brook, NJ

Comprehensive Energy Audit For Kongiganak Health Clinic


Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

LOS ANGELES UNIFIED SCHOOL DISTRICT Policy Bulletin

Energy Benchmarking Report for LaMonte Elementary School Bound Brook, NJ

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity

Energy Assessment Report Clayville Elementary School DRAFT October George Washington Highway, Clayville, RI DRAFT

Optimizing Energy Use in a HealthCare Setting. Michael P. Della Barba Environmental Health & Engineering, Director of Commissioning

Energy in Buildings Understanding the Impacts On Consumption

National Indian Gaming Association 2005 Certification: Energy Management for Cost Savings Larry Kinney Synertech Systems Corporation On behalf of

WAKE TECHNICAL COMMUNITY COLLEGE SUSTAINABLE ENERGY PLAN. Energy Plan

For Point. Prepared For City of Nunapitchuk. June 14, 2012 ANTHC DEHE

EAST ORANGE SCHOOL DISTRICT DIONNE WARWICK INSTITUTE FACILITY ENERGY REPORT 120 CENTRAL AVENUE EAST ORANGE, NEW JERSEY 07017

Do-It-Yourself Energy Audit. Bob Furgeson, PE CEM CBCP GBE CEA Shive-Hattery Architects+Engineering

Bryant University s Energy Guidelines for Sustainability

Allstream Centre Energy Performance Report

PROJECT NAME CLEVELAND CLINIC PROJECT #

Energy Usage Reduction Program

Department of Transportation Rapid City Region Office 2300 Eglin Street P.O. Box 1970 Rapid City, SD Phone: 605/ FAX: 605/

For. Prepared For ANTHC DEHE

Comprehensive Energy Audit For Chevak Vacuum Plant

Comprehensive Energy Audit For. Ambler Water Treatment Plant

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project

Comprehensive Energy Audit For Sleetmute Tribal Office

BOMA s Energy Efficiency Program BEEP Course 4. No- and Low Cost Operational Adjustments to Improve Energy Performance

Why Use A DES ESCO? Benefits of A DES ESCO?

AEE Technical Roundtable Measurement and Verification. Alec Stevens, PE April 8, 2014

2009 FACILITY ACTION PLAN

PSE Efficiency Programs Sheryl Anayas

Comprehensive Energy Audit For Akiak Native Community

MAYWOOD BOARD OF EDUCATION MEMORIAL ELEMENTARY SCHOOL ENERGY ASSESSMENT. For NEW JERSEY BOARD OF PUBLIC UTILITIES CHA PROJECT NO.

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Denver, CO April 10, Contact. Auditor Name Energy. Energy. Xcel Energy. Denver, CO (P) (P)

Comprehensive Energy Audit For Akiak Health Clinic

Energy Efficiency in Multi-Tenant Office Buildings

Energy Data Efficiencies & Inefficiencies. Speaker: Mike Meola

YWCA 1503 S. Denver Tulsa, Oklahoma 5/18/2010 Performed By

Comprehensive Energy Audit For Pitkas Point Tribal Office

Energy Report - February 2008

Xavier University of Louisiana

Retrocommissioning (RCx)

Retrocommissioning Investigation Study of the Sheraton Chicago Hotel

PacifiCorp Annual Review of DSM Programs California

Sample Reports. for. HAP v4.90 Example Problem

Holistic Design Approach For Energy Efficiency ASHRAE TECHNOLOGY AWARD CASE STUDIES

Premium Sample Reports

Campus Annual Energy Use Report

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018

Comprehensive Energy Audit For Alakanuk Water Treatment Plant

ENERGY MANAGEMENT PLAN - HEADQUARTERS. ABC Winery 123 1st Street Franklin, NJ 12345

Sample Reports. for. HAP v4.80 Example Problem

Comprehensive Energy Audit For. Savoonga Water Treatment Plant

Comprehensive Energy Audit For. Old Harbor Water Treatment Plant

Comprehensive Energy Audit For. Kake Water Treatment Plant and Water Dam

Administration Division Public Works Department Anchorage: Performance. Value. Results.

TOP 10 STRATEGIES FOR NEW AND EXISTING BUILDINGS

MiraCosta Community College District Page 1 of 6 Effective/Review Date: 6/7/11, 3/10/15

For Newtok. Prepared For. March 16, 2012 ANTHC DEHE

Klatt Elementary School

Rainwater tank study of new homes

Commissioning and Retro Commissioning Programs Title Slide for Energy Efficiency

Southern York County Library

Compr For & Washeteria

Do You Know. Your Co$ts? Tom Stow Operations & Maintenance Division Manager Clean Water Services

ENERGY MODELING TOOLS: SOLUTIONS FOR CREATING A HIGH PERFORMANCE BUILDING. Presented by Neil Maldeis Energy Solutions Engineering Leader, Trane

Pharmaceutical Sustainability Initiatives

Slana School. Mile 4 Nabesna Road. Slana, Alaska AkWarm ID No. AHTNA-Z93-CAEC-02. Submitted by:

PV Generation Potential 17.1 kbtu/ft2/yr 15.4

Energy Savings Audit

Comprehensive Energy Audit For. Unalakleet Pump House

For. Prepared For. June 11, 2012 ANTHC DEHE

Rye School Buildings. A Comprehensive Energy-Evaluation Report. Rye School District 48 Post Rd. Rye, NH 03840

Building Load and Energy Estimates Analysis. Instructor: Dr. Mumma. October 28, Thesis Building Sponsor s: INOVA Fairfax Hospital

The Energy Program Tricycle: Which Wheel Should You Put in Front?

Natural Gas. April Click on each slide to proceed to the next one.

Compr For. Prepared For City of Teller. Prepared By: ANTHC DEHE Energy

Energy Efficiency in Restaurants and Grocery Stores. CARD, EECBG, and Climate Change Grants for Minneapolis and White Bear Lake

Kitchell Corporation, San Diego Energy Assessment

Retro-Commissioning for Energy Efficiency

Transcription:

Marysville School District Resource Conservation Program John Bingham Marysville S.D. Ray Burton Snohomish Co. P.U.D.

Tools Resource Conservation Program Utility budget Utility tracking Benchmarking Load profiles Program Support Board policy Building operating guidelines Implementation Weekly meetings Setting goals Identifying projects and getting them installed Involve staff New Construction Presenting Results

Tools Utility Budget Marysville S.D. - Utility Cost Breakdown 4/05-3/06 Garbage, $156,167, 9% Sewer, $53,288, 3% Recycling, $27,561, 2% Water, $60,516, 4% Natural Gas, $464,033, 27% Electricity, $945,774, 55% Total Utility Cost = $1,707,339

Tools 2 Years History for Data Base You Can t Manage What You Don t Measure

Benchmarking Where should you be? Your schools compared to each other Your schools compared to other local districts Use per square foot (EUI) Track electric and gas separately Can compare across other Puget Sound utilities Cost per square foot (ECI) Use for comparison only if rates are similar Can t compare PSE area school to PUD area school

Tools Benchmark (EUI EUI) Marysville SD - Energy Use Index ('04-'05) 120 100 80 60 40 20 0 Natural Gas Electricity 10th Street Msvl Middle Sunnyside Tulalip Kellogg Marsh Marshall Heritage Pinewood MAHS Shoultes Cascade Elem Liberty Allen Creek Quilceda Cedarcrest MBTU/SqFt Msvl Jr. M-P High You Can t Manage What You Don t Measure

$1.60 $1.40 $1.20 $1.00 $0.80 $0.60 $0.40 $0.20 $0.00 Tools Benchmark (ECI ECI) Marysville S.D. - Energy Cost Index ('04 - '05) Ntural Gas Electric $/SqFt 10th Street Sunnyside Kellogg Marsh Liberty Cascade Elem Shoultes MAHS Heritage Quilceda Msvl Middle Allen Creek Tulalip Marshall Msvl Jr Cedarcrest Pinewood M-P High

2.5 2.0 1.5 1.0 0.5 0.0 Tools Benchmark - Electric Loads at Night Msvl SD - Electric Loads at Night - November '03 - '04 - '05 '03 '04 '05 Watts/sqft Cascade Liberty Sunnyside Kellogg Marsh Allen Creek Msvl Jr. Tulalip MAHS Shoultes Cedarcrest Msvl Middle Quilceda Pinewood M-P High Marshall

Tools Electric Load Profile Typical week day 290 kw Typical week end

Tools Gas Load Profile Controls put in "hand mode

Program Support Board Policy

Program Support Building Operating Guidelines Marysville School District Building Operating & Energy Conservation Guidelines The following guidelines are set to establish standards to optimize the conditions of our learning and work environment while also conserving energy and natural resources and avoiding unnecessary and costly utility expenses. The implementation of this program is the joint responsibility of all school district staff, students and other users. Lighting Individual classroom lighting should be turned on/off by teacher at beginning and end of each day. Teachers should ensure that lights are turned off when classrooms, shops, etc., are unoccupied for 15 minutes or longer. Lights in gymnasiums, multi-purpose rooms or commons should be turned off if room will be unoccupied for 30 minutes or longer. Whenever possible, natural lighting should be taken advantage of in lieu of indoor lights. Hallways and commons lighting shall be turned off at the end of the instructional day unless afterschool activities require it. Outside lighting should remain off from midnight until 4:30 a.m. Heating HVAC systems should always be operated in the most economical and efficient way possible. The heating system will be set to provide the following temperatures during time of student occupancy: Classrooms/Libraries 68 o -70 o Gyms/Multi-Purpose 68 o Offices 68 o -70 o School Shops 68 o Hallways 65 o O&M and Trans. Shops 65 o Variations from the set schedule can be made by the Maintenance Dept. only for unique or special circumstances. The night setback temperature at all facilities shall be 55 o to 60, including all day during weekends and holidays. All exterior doors and windows shall remain closed during the heating season. Outside air setting shall be set for 15CFM per student in classrooms/libraries. Personal space heaters may not be used. Electrical All electrical equipment such as computer monitors, printers, copiers, coffee pots, etc. must be turned off at the end of individual's workday. Do not turn off computer unit itself as system back-ups and software updates occur during night hours. High-energy use items such as kilns and selfcleaning ovens should be run between 2:00 p.m. and 5:00a.m. (non-peak times) All staff lounge refrigerators should be cleaned out and turned off during extended breaks. Pop machines need to be turned off during extended breaks. Water Report any and all leaks. Never leave faucets running unattended or between use except when cold weather procedures are warranted. Solid Waste and Recycling Each school should develop and implement a recycling plan in order to reduce solid waste. Custodial staff will monitor the quantity and usage of the dumpsters. Dumpster size and frequency of pick-up will be adjusted if needed. For more energy information, please contact Maintenance at Ext. 20847.

Checklists for extended breaks

Implementation Weekly Meetings Who - Maintenance Manager - Building Operator - Lead HVAC Tech - Lead Custodian - RCM Topics - Status of Existing Projects - New ideas to save - Load Profiles (Monthly) - Who should be involved in projects Follow-up To Do lists - Each Member

Implementation Establish Goals Based on existing utility costs 1 st Year = 10% ($170,000 - estimate) 2 nd Year = 15% ($250,000 - estimate) 3 rd Year = 20% ($340,000 - estimate) Marysville s results after 5 yrs = $1,100,000 (20% maintained savings - actual)

Implementation Ways to Identify Projects Night walk-thrus It s 3:00 a.m. Do you know where your energy use is? Monitoring (sub-metering) Controls review Bill reviews (checking for errors) Employees suggestions Typical measures Lighting Mechanical Other

Why non-school hours? After school, savings opportunities are abundant No capital budget dollars needed No impact to building systems No impact to staff or students Consider after hours user groups NO BRAINER!!!

Why should you care? $$$$$$$$$$$$$$$$$$$$$$$ 5 times more hours non-school than during school From 7:00am 3:00pm M-F = 1,440 hrs/yr Non-school = 7,320 hrs/yr Large % of energy use occurs during nonschool hours

Worst Case Scenario School hours Energy use = 40% Non-school hours Energy use = 60%

Best Case Scenario School hours energy use = 60% Non-school hours energy use = 40%

Typical loads left on at night HVAC Heating to occupied temperatures Supply and exhaust fans running Outside air dampers open Lights All exterior Hallway Common areas Plug Loads Computers Pop machines Personal refrigerators

Implementation Ways to Identify Projects Night walk-thrus Monitoring (sub-metering) Controls review Bill reviews (checking for errors) Employees suggestions Typical measures Lighting Mechanical Other

Temporary Meters Digital Thermometers Lighting logger Motor Logger Occupancy Logger Temperature Logger Electrical Load profiles Air Flow

Implementation Ways to Identify Projects Night walk-thrus Monitoring (sub-metering) Controls review Bill reviews (checking for errors) Employees suggestions Typical measures Lighting Mechanical Other

Review controls annually Review EMS/time-clock settings Occupied/unoccupied times Start times versus occupied times (warm up period) Temperature set points Dead-bands Economizer enabled Program holiday/non-school day schedules at beginning of year

Implementation Ways to Identify Projects Night walk-thrus Monitoring (sub-metering) Controls review Bill reviews (checking for errors) Employees suggestions Typical measures Lighting Mechanical Other

Understanding Your Utility Bill

Understanding Your Utility Bill

Implementation Ways to Identify Projects Night walk-thrus Monitoring (sub-metering) Controls review Bill reviews (checking for errors) Employees suggestions Typical measures Lighting Mechanical Other

Encourage staff to submit: Needed repairs Control problems Ideas for conservation! THEY ARE YOUR BIGGEST ALLIES!!!

Implementation Ways to Identify Projects Night walk-thrus Monitoring (sub-metering) Controls review Bill reviews (checking for errors) Employees suggestions Typical measures Lighting Mechanical Other

Typical lighting measures

Typical mechanical measure Programmable thermostats

Typical other measures Pool Cover CO 2 Control of Outside Air Motion Sensors for Lights Photocell Controls for Lights DDC System for HVAC Adjustable Speed Drives on Larger Motors

Implementation Getting Projects Installed No cost/low cost O&M measures (Use successes to promote longer payback measures) Low fruit first (most cost-effective) Identify funding sources DON T FORGET UTILITY FUNDING!

New Construction Have RCM involved from beginning Set energy performance goals Use utility incentive programs Start commissioning agent early Secured $250,000 grant from State for Elementary #11 to construct to WSSP

Savings from RCM Program Electric Marysville SD - Total Electric Usage 14,000,000 12,000,000 Cummulative kwh's 10,000,000 8,000,000 6,000,000 4,000,000 Aug Jul Jun May Apr Mar Feb Jan Dec Nov Oct Sep 2,000,000 0 '00-'01 '01-'02 '02-'03 '03-'04 '04-'05 '05-'06 Electrical Savings over 5 years = $450,000 Additional Equipment Energy Usage = $140,000* Total Savings = $590,000 * = 23,500 sq.ft. and 2,600 computers

Savings from RCM Program Natural Gas Marysville SD - Total Gas Usage 700,000 600,000 Cummulative Therms 500,000 400,000 300,000 200,000 100,000 Aug Jul Jun May Apr Mar Feb Jan Dec Nov Oct Sep 0 '00-'01 '01-'02 '02-'03 '03-'04 '04-'05 '05-'06 Natural Gas Savings over 5 years = $600,000

Present Results Individual Schools Marysville SD - EUI History 160 140 120 100 80 60 40 20 0 '00-'01 '01-'02 '02-'03 '03-'04 '04-'05 Heritage Msvl Middle Tulalip 10th Street Kellogg Marsh Marshall Sunnyside Pinewood Cascade Elem MAHS Shoultes Liberty Allen Creek Quilceda MBTU/SqFt Msvl Jr. Cedarcrest M-P High 30% reduction 30% Reduction at M-P High

Present Results Entire School District Marysville School District Cumulative Energy Use (KBTU's) 120,000 100,000 80,000 60,000 40,000 20,000 0 w/o added electric load '00-'01 '01-'02 '02-'03 '03-'04 '04-'05 '05-'06 Aug Jul Jun May Apr Mar Feb Jan Dec Nov Oct Sep 20% Sustained Total Energy Savings

10 Steps to a successful Resource Conservation Program 1 - Find a conservation champion (RCM) 2 - Track your utilities 3 - Understand your utility bills 4 - Call your local utilities 5 - Benchmark your facilities 6 - Review operating parameters 7 - Implement O&M saving measures 8 - Secure financing for capital projects 9 - Implement capital projects 10 - Present results

Marysville School District RCM Program John Bingham Marysville S.D. (360) 653-0846 john_bingham@msvl.k12.wa.us Ray Burton Snohomish P.U.D. (425) 783-8654 8654 rlburton@snopud.com