Float Flow Meters series NF

Similar documents
Flow Meters with Float constructive series AF and BF for liquids and gases with remote flow indication

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

SITRANS F flowmeters. SITRANS F VA Tubux variable area meter 4/279. Overview

U6 SERIE PRINCIPLE TECHNICAL FEATURES. Measuring range: 1 to 1600 m 3 /h [Water at 20 C] 180 to Nm 3 /h [normo m 3 /h of air] MATERIALS

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

LIQUID METER TYPE FMO

VARIABLE AREA FLOWMETER EASYFLOW.

Flow - sight glass, flap, ball

R-100 Series GLASS TUBE FLOWMETER SIMPLE, BUT RELIABLE BEST COST PERFORMANCE GENERAL FEATURES MODEL CODE

Rotameter. Series 134 glass tube variable area flowmeter. Data sheet Principle of operation. Philosophy. process measurement solutions

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

UTECO. Temperature Probes Overview. Temperature Probes for all Industries Level Switches Accessories, Cables & Transmitters

10A4500 / 10A4600 VA Master TM Indicating Flowrator

POLYPROPYLENE SENSOR LIGHT WEIGHT SENSOR COMPLETELY IN POLYPROPYLENE

Visual Level Indicators VLI

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Dorot Irrigation Meter

Resistance Temperature Detectors Mineral Insulated Thermocouples Thermoelements, Accessories and Service All-round supplier

Flow - sight glass, flap, ball

Scales: (Inches) Nominal Length Type and Location. Percentage on tube or Direct Reading on external metal scale with blank tube

Weir Valve Selections

FM MAG GAUGE METAL TUBE LEVEL GAUGE. MAG GAUGE Metal better than Glass!

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Instrumentation for Water Applications

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters

PCL Series Electromagnetic Flowmeters

TEK-B AR 3800E. Multivariable Pressure Transmitter. PRESSURE. Technology Solutions

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

Standard features. Service intended. Design Internal diaphragm. Accuracy Refer to gauge model

QSE MAG FLOW METER OM SERIES OVAL GEAR METER. Water Water-Based Liquid Solutions. Oils Molasses

Ø mm. SYSTEM KAN-therm. High quality for reasonable price TECHNOLOGY OF SUCCESS ISO 9001

Standpipe Meters and Hydrant Flushing Unit STM-E, STM-N, STM-T, STW The mobile tapping points for taking water from hydrants

ELECTROMAGNETİC FLOWMETERS

Level Switch. Series. instrumentation for fluids LC40. Instructions Manual

SMP Battery Powered Electromagnetic Flowmeters. Sizes 25, 50 & 80mm

Differential pressure

WYATT Orifice flow PrOducTs

EXTREME. When the heat and pressure are on NONCONTACT POSITION AND PRESSURE MEASURING SYSTEMS

SAPAG CHECK VALVES MODEL CLASAR

PENBERTHY MODELS RL AND TL DIRECT READING LIQUID LEVEL GAGES

CORROSIVE PROCESS ENVIRONMENT

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

CAPACITIVE LEVEL METERS CLM 36

Supmea ph sensor Datasheet

Our customers additionally benefit from the professional after-sales service, e.g. calibation and commissioning of our group.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

CORROSION-RESISTANT PUMPS.

SURFACE TEMPERATURE SENSORS

Static Mixers. Operation, Installation and Maintenance Instructions. Custom Engineered Solutions. to Meet Your Specific Industry Needs

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

Subject: Guidance on Corrosion Assessment of Ex Equipment

H250 M40. The modular variable area flowmeter

4-Beam-Turbidity Meter ITM-4

INTRODUCTION TO WELDED METAL

Models 1350G & 1355G. Low Flow Glass Tube Flowmeters. Ships in 5 days. Overview. Product Features. Variable Area

P430 Series. Glass Tube Variable Area Flow Meter. Product Features and Options: Contact Information:

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

CORROSIVE PROCESS ENVIRONMENT

ON-OFF free flow valves Series MVMFL/BW

Electrical Resistance Monitoring

ISO 9001:2008 certified

SECTION CHEMICAL FEED SYSTEM

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

Extreme Environment SENSOR DATA SHEET kamansensors.com. For high pressure, low temperature, and high temperature applications

S E N S O R D A T A S H E E T. Extreme Environment. For high pressure, low temperature, and high temperature applications

CATALOG HHD ELECTROMAGNETIC FLOWMETER

Emission Line

Technical information

Flanged chemical seals series D

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

ZDM. Positive Displacement Flowmeter

WP-SDC COPPER CAN REGISTER WOLTMAN WATER METER

METAL & DUAL SEATED PISTON VALVES

Isolation Gaskets 101

O to 15,000 psi and media temperature between -130 F and 752 F. Examples of Typical Diaphragm Seal Applications

Model 140MX Flowmeter Functional Overview

Diaphragm pressure gauge per EN 837-3,

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

Georg Fischer Waga N.V. The connection for all pipe diameters Restraint - non restraint DN50 - DN600 MULTI/JOINT 3000 Plus

CH88 In Situ Flue Gas Oxygen Transmitter

BLÜCHER. Pipe. Training

Thank You for Attending Today s Webinar:

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

Neotecha Type KR Ball Check Valve and Type SG Sight Glass

Weir Valve Selections

SD14 Balanced Flow Meter

Coriolis Mass Flow Meter

6. SHEATH MATERIALS, THERMOWELLS, FITTINGS, AND TERMINATIONS

Soft Seated Butterfly Valves Ductile Iron Wafer Body ANSI/ASME to 6 Sizes

VLM10 In-line Vortex Mass Flow Meter

ABSORPTION MEASURING INSTRUMENT

Transcription:

Float Flow Meters series NF - Quality design - High corrosion resistance - Reliable measurement principle - Low weight and small dimensions Doc. no.: 22, en_cat_nf, 8/2015

Usage Flowmeters type NF are designed to measure instantaneous flow of liquids and gases in harsh environments. Device resistance is provided by a lightweight thin-walled metal sheath. Connection of the flowmeter to the plastic pipes, PP, PVC is by welding, gluing or on request by thread. Technical specifications Operating temperature of the measured medium Max. operating pressure (without shocks) Accurancy class 0-100 C material PP 0-60 C material PVC 1 MPa PP 0,6 MPa - PVC 2,5 %; 1,6 %; each unit is calibrated Connection type flanged connections - CSN, PN 10, 16, 25, 40 Materials of main parts Connection piece Float Measuring tube Sealing elements PP (PVC, brass, stainless steel) upon request thread stainless steel (PP, PVC, PVDF, Al alloy) borosilicate glass vacuum-molded, reinforced NBR (FPM, EPDM) Installation, operation, maintenance Before mounting the flowmeter remove the security against the float movement during transport. Working position vertical with media flow from the bottom. Before connecting the meter pipe has to be flushed. Operation and maintenance is limited to checking for leaks and clean the measuring tube. When using the meter, protect your face shield, especially in aggressive media and at higher pressures. Avoid pressure surges that could cause a sharp jolt of the float to the top stop. Accessories Flowmeters can be equipped with flow sensor Limit contacts: SP1 - min Continuous scanning: SP4 SP2 max SP3 for small flow Evaluation unit VZI 211R: flow display on the screen and a converter with output example. 4-20 ma; two limits - output contact 220 V 2A. Flow Indicator ERT 7000: totalizer - 8 digits 2 of 5

Flow Indicator ERT 50000: Flow display - 6 digits Counter A - 8 digits Counter B - 7 digits - daily counter Converter e.g. 4-20 ma Ordering When ordering you must know: media type concentration % density viscosity temperature and pressure measuring range units 3 of 5

Manufacturer type number Example: NF 8 02 K1 P2 1. 2. 3. 4. 5. 1. 2. 3. 4. 5. Type NF connection for welding, plastic glueing NFV connection for welding, plastic glueing, with guided float Size of measuring tube 04, 03, 02 8, 9, 10, 11 Design float emblem 01 basic float shape 02 modified float shape for greater flow 03 basic float shape with the core 04 modified float shape with the core for greater flow 05 basic float shape with magnet 06 modified float shape with magnet for greater flow 07 basic float shape with core and magnet 08 modified float shape with core and magnet 09 lightweight 10 bead Float material Metal K1 stainless steel class 17 246 K2 stainless steel class 17 348 K5 alloy AL K6 titanium Plastic P1 PVC P2 PP P3 PTFE (Teflon) Fittings material - inserts - not applicable if the same material as the float Metal K1 stainless steel class 17 246 K2 stainless steel class 17 348 K5 alloy AL Plastic P1 PVC P2 PP 4 of 5

Measuring ranges values and connection dimensions Type Measuring range l/h Connecting dimensions Water +15 C Air +20 C; 101,3 kpa A B C D E NF04.01K1 0,4-2,5 10-100 452 16 20 67 40 NF03.01K1 0,6-6 15-220 452 16 20 67 40 NF02.01K1 1-12 30-450 452 16 20 67 40 NF01.01K1 2-17 60-600 452 16 20 67 40 NF1.01K1 4-35 70-1 100 427 25 20 67 40 NF2.01K1 8-66 300-2 300 427 25 20 67 40 NF3.01K1 20-145 450-4 300 427 25 20 67 40 NF4.01K1 30-280 1 100-9 000 427 25 20 67 40 NF4.02K1 40-350 - 427 25 20 67 40 NF5.01K1 40-540 2 000-11 000 427 25 20 67 40 NF6.01K1 100-1 000-427 32 20 67 40 NF6.02K1 200-1 250 3 000-22 000 427 32 20 67 40 NF7.01K1 200-1 800 3 000-32 000 414 63 28 102 72 NF7.02K1 200-2 300-414 63 28 102 72 NF8.01K1 600-3 700 8000-60 000 494 63 28 102 72 NF8.02K1 800-4 000-494 63 28 102 72 NF8R.01K1 400-3500 - 446 63 28 102 72 NF9.01K1 1 200-6 300 15 000-100 000 523 63 28 102 72 NF9.02K1 2 500-8 000-523 63 28 102 72 NFV9.01K1 2 500-11 000 40 000-170 000 523 63 28 102 72 NFV9.02K1 8 000-18 500 40 000-200 000 523 63 28 102 72 Note.: Measuring ranges for water are value for stainless steel floats, if different material is used the flow is reduced. On request other connecting dimensions, threads etc. Requirements for other measuring ranges, other media, as well as requests for other materials to be discussed with the manufacturer. 5 of 5