INSULATION PRODUCTS. Selection Guide & Reference Chart

Similar documents
SECTION HVAC INSULATION

SECTION PLUMBING INSULATION

Mechanical Insulation for Refrigeration Systems

MAKE ROOFS LAST LONGER

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

SECTION SELF-ADHERING SHEET FLASHING

Pressure Sensitive Tapes. for Insulation and General Purpose. Innovative Insulation Specialties. Abatement. Industrial. Packaging

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

FireX Fire Stopping Mastic FM

TAPE SOLUTIONS FOR HVAC SHURTAPE.COM TAPE

LEED POINT ELIGIBLE, AIRTIGHT GREEN POINT CONTRIBUTORS SHURTAPE.COM TAPE

Commercial Moisture Cure Sealants

SECTION PIPING INSULATION

RESTORATION, ABATEMENT AND REMODELING TAPES

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

Division 15 INSULATION Section 15100

MECHANICAL SOLUTIONS REFERENCE GUIDE FIBERGLAS FOAMGLAS THERMAFIBER FOAMULAR

DIVISION 23 HEATING, VENTILATING, AND AIR CONDITIONING (HVAC) SECTION HVAC INSULATION

Liquid-Applied Roof Solutions ACRYLIC & SILICONE COATINGS PRIMERS & ACCESSORIES

EPIC RESINS COMPOUNDS AND RESINS FOR INDUSTRY STRUCTURAL. adhesives

Pressure Sensitive Tapes for Industrial Insulation and General Purpose

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Design & Construction Standards, Revised January

B C M T e c h n i c a l, L L C A v o n I n d u s t r i a l D r. R o c h e s t e r H i l l s, M I P h o n e : T o l

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

Adhesive Films 350 F Cure

INDUSTRIAL CONSTRUCTION AND RESTORATION TAPES

SECTION SELF-ADHERING SHEET WATERPROOFING

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

J&L Building Materials, Inc. Commercial Roofing

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

.1 Thermal insulation for insulated piping and piping accessories affected by construction and new pipe sections as indicated on drawings.

EVALUATION REPORT Soprema, Inc. 310 Quadral Drive Wadsworth, OH 44281

PERMATHERM, INC. SPECIFICATION FOR CHILLED WATER PIPE INSULATION

1 of 17. PO Box Bellevue Rd, Newark, DE V F

Liquid Membrane Systems Product Guide

Student Services & Classroom Addition

PERMATHERM PIPE INSULATION PRODUCTS

TOPCOAT Restoration Specifications Fiberglass & MB Granulated Cap Sheets

EFFISUS EASYREPAIR MEMBRANE

PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION

PERMATHERM, INC. SPECIFICATION FOR COLD/CRYO PIPE INSULATION

SECTION HVAC INSULATION

Ev erguard Adhesiv es Guid e. Updated: 3/ 17

TAM-PRO CEMENTS & COATINGS

Dist. by: BEST MATERIALS Ph:

Commercial Moisture Cure Sealants

This Design guideline contained herein includes the requirements for mechanical insulation at The University of Texas at Austin

Foil-Faced Fiberglass Fabric 84215/9480 HT

MECHANICAL SOLUTIONS REFERENCE GUIDE FIBERGLAS FOAMGLAS THERMAFIBER FOAMULAR

Tapes, Fasteners & Sealants. Product Information Guide. The right solutions. The right products.

SECTION DUCT INSULATION

PIP INSC1000 Cold Service Insulation Materials and Installation Specification

PRESTON HEALTH SERVICES ARCHITECT S NO. 2700

DMS-6300, Waterproofing

University of Delaware

FOAMGLAS INSULATION SPECIFICATION

DMS WATERPROOFING

B. Refer to Section : Air Distribution for lined ductwork requirements.

Caulks & Sealants. Professional. Catalog

SPECIALTY PRODUCTS AQUACHECKTM ASPHALT PRODUCTS - SPECIALTY PRODUCTS

FlexClad Duct and Pipe Sealing System

Roof Repair Sealants

Pressure Sensitive Adhesives for HVAC/R, Mechanical and Metal Building Insulation. Tapes, Fasteners & Sealants Product Catalog

ASTM Volume 04.06, November 2016 Thermal Insulation; Building and Environmental Acoustics

the professional s choice. tam-pro black and white cements & coatings. tamko.com

PRODUCT PORTFOLIO or visit uniflexroof.com 101 PROSPECT AVE NW, CLEVELAND, OHIO PD TAGUNFL 640/18. 08/18 Uniflex Coatings

Pol-E-Base Modified Bitumen Roof System

PROJ. NO SECTION HVAC DUCT INSULATION

ASPHALT CEMENTS & COATINGS. Roof Mastics Protective Asphalt Coatings Asphalt Primers Aluminum Coatings

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5

PRODUCTS LIST. Apply with confidence.

CS-75 Water-Based Adhesive Surface Primer

SECTION SHEET MEMBRANE WATERPROOFING

Nutech Roof Coatings Nutech Paint Application Instructions & Guidelines Nutech Roof Coating Range of Products

PART 10 ADHESIVES AND SEALANTS. Adhesives Sealants Tapes

Pipe Protection Tape System

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

PERFORMANCE COATINGS. PRODUCT CATALOG Vol. 18

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

UBC Technical Guidelines Section Edition Insulation of Tanks, Steam and Condensate Piping Page 1 of 6

SECTION (15081) - HVAC INSULATION

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION CONCRETE TOPPING

SECTION SELF-ADHERING SHEET WATERPROOFING CCW-711

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

When Platinum means more than just a metal!

The Disclaimer located on the reverse side of the title page of the OAA Rain Penetration Practice Guide applies to each section of the Guide.

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

Copolymer BEFORE. Copolymer DURING. Copolymer AFTER. (800) TRI-CHEM 3

Tube Insulation. Fiber Free

838 Coatings System Specification Single-Ply Restoration (838 SPR)

Typical Viscosity (CPS) Temp. Range ( F) -65 to to 300. Product Number/ Description Typical Use Color Size UPC ( )

Waterproofing Systems Liquid Applied.

A. Section includes fluid applied, vapor permeable membrane air barriers.

PITTWRAP HS (HEAT SEAL) JACKETING Product Datasheet

Resilient Flooring Installation Solutions

Transcription:

NSULATON PRODUTS Selection Guide & Reference hart pg. 2-3 pg. 4-5 pg. 6

Mastics and oatings Typical Use ommercial () or ndustrial () Product Name Vapor Sealing nsulation Facing and Jacketing (FSK, ASJ, FRK) Lagging Adhesive/ oating Fiber Glass and Mineral Wool Rigid nsulation (ellular Glass, PR, Phenolic) Polystyrene oating 1 alcium Silicate TTE-FT oating 30-35 (White) SEALFAS oating 30-36 (White) SEALFAS oating AF 30-36 AF (White) (Fungus Resistant) SEALFAS oating MA 30-36 MA (White) (Marine Grade) VAPOR-FAS WB oating 30-65 (White) VAPOR-SAFE oating 30-80 (Brush), 30-90 (Trowel) VAPOR-SAFE oating AF 30-80 AF (White) (Fungus Resistant) WEATHERTE Mastic (Brush) 46-50 (White), 46-51 (Gray) SEALFAS G-P-M Mastic 35-00 (Trowel), (White).. Mastic (Black) 60-25 (Trowel) 60-26 (Heavy Duty Airless Spray) MONOLAR Mastic, oatings 60-38 (White), 60-39 (Gray) MONOLAR Mastic 60-90, 60-91 (Trowel); 60-95, 60-96 (Spray) (White/Gray) Fire Resistive.. Mastic 65-05 (Black) H.. Mastic 90-07 (Black) FOSTER Vapor Barrier Membrane and Jacketing VAPOR-FAS 62-05 Jacketing (Aluminum or White) (Embossed or Smooth Finish) 2 BEST GOOD.. WRAP 50 (Black).. WRAP 30 (Black) This guide is provided as a quick reference. Please see product data sheet for specific test methods, installation methods and additional information. 1 Always choose white colored coating for exterior use on polystyrene insulation. Do not use solvent based products with polystyrene.

General Description Type of Volatile LEED EQ REDT Permeance Value as Measured in US Perms 2 Flash Point Flexible fire resistive vapor retarder coating for rigid insulation and fittings. Also used to vapor seal ASJ facing laps and punctures. Meets ML--19565- Type and QPD listed. 0.05 100 F (38 ) A tough, washable, fire resistive coating for most indoor applications. Used as an adhesive and coating with lagging cloth and other fabrics. Meets ML-A-3316 lass 1, Grade A requirements and is QPD listed. U.S. oast Guard 164.012 certified. X 0.4 to 1.5 Offers the same properties of Foster SEALFAS 30-36 with added fungus protection. Passes ASTM D 5590 with '0' growth. U.S. oast Guard 164.012 certified. X 0.4 to 1.5 Specially formulated lagging adhesive and coating for marine applications. Meets ML-A-3316 lass 1, Grade A requirements and QPD Listed. U.S. oast Guard 164.012, 164.112 certified and SOLAS/MO approved. An economical, fire resistive, vapor retarder coating for use over many types of thermal insulation on piping and equipment operating between 33 F and ambient temperatures. A water-based vapor retarder for indoor or outdoor use. Low odor, non-toxic, and low VO. Use on cold operating systems. Meets ML--19565, Type requirements and is QPD listed. X 0.4 to 1.5 X 0.08 X 0.08 The same qualities of standard Foster VAPOR-SAFE 30-80 with added fungus protection. Passes ASTM D 5590 with '0' growth. X 0.08 -based, breather, weather barrier coating for indoor and outdoor use. Used over most types of insulation systems operating above ambient temperatures. Also used on cold or dual temperature systems where the insulation facing provides a vapor barrier. High performance, general purpose water-based, weather barrier mastic for indoor and outdoor use. Fire and chemical resistive. Excellent application properties for heavy duty applications. X > 1.0 X > 1.0 Economical asphalt cutback vapor retarder mastic for insulation protection on cold systems. Tough and durable for exterior applications. Also suitable for underground applications. 0.02 104 F (42 ) High performance SPE (Hypalon*) based vapor retarder mastic. Tough, flexible, elastomeric, chemical and fire resistive. The preferred product for most cold and dual-temp work including cryogenic insulation systems. An elastomeric resin and SPE (Hypalon*) containing vapor retarder. A tough, flexible, fire resistive finish which provides outstanding chemical and weather resistance. Used on cold and cryogenic insulation systems. 0.025 0.03 103 F (40 ) Flash Point 110 F (43 ) Asphaltic cutback vapor retarder mastic with added fire resistance. For use on exterior applications on cold insulation systems. 0.03 104 Economical asphalt emulsion. A protective weather coat that is easy to apply and will not shrink or crack. Use on hot operating, exterior insulation systems. X 1 > 200 F ( 93 ) A weather resistant, 5-ply aluminum and polymer laminated vapor barrier jacketing with a peel and stick PSA adhesive. For outdoor or indoor use over cold and dual temperature insulation systems including roof-top ductwork and chilled water piping. A 50 mil flexible vapor retarder sheet membrane. t is used to provide a moisture and vapor retarder film over cold and cryogenic piping and equipment insulation. t is also suitable for underground piping. A 30 mil flexible vapor retarder sheet membrane. t is used to provide a moisture and vapor retarder film over cold and cryogenic piping and equipment insulation. n/a n/a 0.00 n/a n/a n/a <0.015 n/a n/a n/a <0.02 n/a 2 See PDS for methods and test conditions. * hlorosulfonated Polyethylene Rubber (SPE) is also known as Hypalon, a trademark of Dupont Performance Elastomers, and is no longer produced by Dupont. 3

Adhesives Product Name and ode Number General Description Type of Volatile Flash Point SEALFAS Adhesive/oating 30-36 30-36 AF (Fungus Resistant) 30-36 MA (Marine Grade) -based lagging adhesive and coating for adhering canvas and fiberglass cloth over insulation. Meets ML-A-3316 lass 1, Grade A requirements. See coatings page for 30-36 AF and 30-36 MA. Foster S.M. Adhesive 81-10 (Brush, Spray) Quick setting, rubber-based adhesive for bonding fibrous glass and acoustical duct liner. ASTM 916 Type V. -7 F (-22 ) Fibrous Adhesive 81-27 (Brush, Trowel) Sodium silcate-based adhesive for bonding calcium silicate insulation to itself and to substrates. ML--24244, grade available. Fire Resistive Adhesive 81-33 (Trowel) An excellent adhesive for bonding insulation to most structural surfaces. Also used for fitting fabrication and joint sealing with polyurethane and polyisocyanurate. 110 F (43 ) LAGFAS Adhesive 81-42 W Quick setting, water-based, thixotropic adhesive for sizing and adhering canvas, glass cloth and other fabrics to insulation. Washable and mildew resistant. Lower viscosity than 30-36. ST-SAFE Adhesive 85-15 (Brush) Fast-setting rubber adhesive for adhering low density fibrous insulation to sheet metal and to most other construction materials. ASTM 916 Type V. -7 F (-22 ) SPARK-FAS Adhesive 85-20 (Brush) Non-flammable, quick-setting adhesive for bonding fibrous insulation (up to 6 lb density) to sheet metal and aluminum. Also for lap sealing. ASTM 916 Type. QUK-TAK Adhesive 85-60 (Brush, Spray) High tack, water-based adhesive for attaching low density fibrous insulation and duct liner to painted and unpainted metal. Also may be used for contact applications. ASTM 916, Type. SPARK-FAS WB Adhesive 85-70 (Brush, Spray) -based adhesive used to adhere fibrous glass or mineral wool insulations (up up 6 lbs density) to painted or unpainted metal surfaces. ASTM 916, Type, ML-A-3316, lass 2 and QPD listed. DRON ontact ement 85-75 (Brush) A non-flammable contact cement with high initial strength. Used for lap sealing and bonding two impermeable surfaces. Multi-Purpose Adhesive 97-15 (Trowel) -based, high wet grab adhesive for attaching fibrous insulation and polystyrene foam to metal and concrete. ellular Glass & Urethane Adhesive/Sealant 81-84 (Trowel) (Two Part Reactive ure) Used to bond cryogenic and low temperature insulations to themselves and to metal and masonry substrates. hemically cures to form a strong yet flexible bond. May be used down to -260 F (-163 ) with PR insulation. Part A&B Blended over 200 F (93 ) ellular Glass & Urethane Adhesive/Sealant 81-84 NH (Trowel) (Two Part Reactive ure) Halide-free adhesive for bonding cryogenic and low temperature insulations to themselves and to stainless steel substrates. hemically cures to form a strong yet flexible bond. May be used down to -260 F (-163 ) with PR insulation. Part A&B Blended over 200 F (93 ) ryogenic Adhesive 82-77 (Trowel) (Three Part Reactive ure) A chemically curing, 100% solids, three-component epoxy adhesive with a lower service temperature of minus 320 F (-196 ) Wet Flammability <250 F (121 ) 4

Suggested Use 1 nsulation Type Attachment Joint and Lap Sealing Lagging Fitting Fabrication Duct Liner Fiberglass and Mineral Wool PR/ Polyurethane/ Phenolic ellular Glass Polystyrene alcium Silicate Rubber Foam BEST GOOD 1 This guide is provided as a quick reference. Please see product data sheet for specific test methods, installation methods and additional information. 5

Sealants Product Name and ode Number General Description Service Temperature Limits at oated Surfaces Type of Volatile LEED EQ redit Flash Point ryolar 1K Vapor Stop Sealant 90-61 A one component, elastomeric, ready to use, vapor stop sealant for cold and cryogenic applications. Formulated for easy application by brush with no need to mix. Apply to PR, cellular glass and metal substrates. -320 F to 250 F (-196 to 121 ) 115 F (46 ) ryogenic Vapor Stop Sealant 90-66 (Two Part) A two part sealant / coating designed for use in cryogenic applications. t is suitable for application to PR foam, cellular glass and fibrous glass insulations in conjunction with aluminum and steel. ures to a tough elastomeric film. -320 F to 250 F (-196 to 121 ) 80 F (26.7 ) FOAMSEAL Sealant 30-45 N Vapor barrier joint sealant that remains flexible and will not shrink or crack. Also used for flashing metal jacketing and bedding of rigid insulations including cellular glass. PR and polystyrene. -100 F to 300 F (-73 to 149 ) (5%) X 142 F (61 ) ELASTOLAR Sealant 95-44 Elastomeric vapor barrier joint sealant and flashing compound. For insulation, masonry and metal jacketing. Aluminum pigmented. Apply with a trowel or caulking gun to all insulations except polystyrene foam. See data sheet. -40 F to 250 F (-40 to 121 ) X 105 F (41 ) FLEXTRA Sealant 95-50 Non-hardening, high solids joint sealant. Remains soft in joint, but skins on surface to reduce bleed through. Apply to joints of PR, polyurethane and cellular glass insulations. Not for exposed joints, flashing or use with polystyrene. Apply with a trowel to all insulations except for polystyrene foam. See Data Sheet. -200 F to 160 F (-129 to 71 ) X 145 F (63 ) RENFORNG MEMBRANES Mast-a-Fab 42-22 A white leno weave synthetic fiber reinforcing membrane with 9" x 8" mesh size. Easy to handle yet superior to glass mesh because of its elastic properties. hil-glas #10 A 10' x 10' glass mesh. Used to reinforce mastic, coatings and sealants. This guide is provided as a quick reference. Please see product data sheet for specific test methods, installation methods and additional information. 6

Vapor Stop Sealant Reinforcing Membrane Jacketing Sealant Joint Sealant Mastics & oatings General Notes 1. The recommendations in this selection guide are of general nature only. Refer to the product data sheets to be certain that the selected Foster product meets all the requirements of the application. 2. Do not apply exterior weather barrier coating on horizontal surfaces that might be subject to prolonged ponding of water. 3. f insulation cement is used, it must be completely dry before applying Foster mastics or coatings. Prime as required. 4. Because of the variation in surface characteristics of facing materials, we recommend that the user conduct their own adhesion test when choosing a coating or mastic for foil, kraft and plastic-faced insulations. 5. The Foster products listed in this guide are for professional use only. 7

H.B. Fuller onstruction Products nc. 1105 South Frontenac Street Aurora, L 60504-6451 Phone: (800) 832-9002 fosterproducts.com 2014 H.B. Fuller onstruction Products nc. Form# FPSGR N1014-16