ONLINE MONITORING OF CORROSION UNDER CATHODIC PROTECTION CONDITIONS UTILIZING COUPLED MULTIELECTRODE SENSORS

Similar documents
ONLINE MONITORING OF UNDERCOATING CORROSIONS UTILIZING COUPLED MULTIELECTRODE SENSORS. Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA ABSTRACT

REAL-TIME MONITORING OF CORROSION IN SOIL UTILIZING COUPLED MULTIELECTRODE ARRAY SENSORS. Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA

MEASUREMENT OF CUMULATIVE LOCALIZED CORROSION RATE USING COUPLED MULTIELECTRODE ARRAY SENSORS

COMPARISON OF OXIDATION POWER SENSOR WITH COUPLED MULTIELECTRODE ARRAY SENSOR FOR MONITORING GENERAL CORROSION

Selected Publications and Abstracts on Multielectrode Array Sensors for Corrosion Monitoring

Threshold Chloride Levels for Localized Carbon Steel Corrosion in Simulated Concrete Pore Solutions Using Coupled Multielectrode Array Sensors

Galvanic corrosion evaluation of 6061 aluminum coupled to CVD coated stainless steel Elizabeth Sikora and Barbara Shaw 6/9/2016

LOCALIZED AND GENERAL CORROSION OF COPPER IN AZOLES AND SILICA INHIBITED ZERO BLOWDOWN COOLING WATER IN AN AUTOMOTIVE PLANT

ROLES OF PASSIVATION AND GALVANIC EFFECTS IN LOCALIZED CO 2 CORROSION OF MILD STEEL

NACE Paper No

Laboratory Experiments in Corrosion Engineering II

Corrosion Damage Monitoring of Stainless Steel by Acoustic Emission

Effect of Oxidizer on the Galvanic Behavior of Cu/Ta Coupling during Chemical Mechanical Polishing

Corrosion Rate Measurement on C-Steel

Corrosion Control and Cathodic Protection Data Sheet

Threshold Chloride Concentration of Stainless Steels in Simulated Concrete Pore Solution

NACE CORROSION 2008 TEG 096X Symposia - Paper 1421

RAPID MACROCELL TESTS OF 2205 AND XM-28 REINFORCING BARS

Potentiodynamic Scanning (PDS) of Stainless Steel Karen Louise de Sousa Pesse

The Passivation Behavior of Carbon Steel Rods of Nepal in Different Media

A STUDY OF PROTECTIVE IRON CARBONATE SCALE FORMATION IN CO 2 CORROSION

Effect of soil compositions on the electrochemical corrosion behavior of carbon steel in simulated soil solution

SIGNIFICANCE OF HYDROGEN EVOLUTION IN CATHODIC PROTECTION OF STEEL IN SEAWATER

Galvanic coupling between carbon steel and stainless steel reinforcements. Qian, S.; Qu, D.; Coates, G. NRCC-48162

Hydrogen Permeation of Pipeline Steel under Sour Condensate Film Condition

Sealing of Hard Chrome Plating

2) Galvanic or Two-Metal corrosion

SERBIATRIB th International Conference on Tribology. Kragujevac, Serbia, May 2011

The Electrochemical Behavior of Carbon Steel Wires of Nepal in Different Environments

Corrosion Mitigation Systems for Concrete Structures

Thermodynamics and Electrode Potential ME Dr. Zuhair M. Gasem

NOTICE. Office of the Chief of Naval Research Department of the Navy Code OOCCIP Arlington, Virginia R PATEN=

Rusting is an example of corrosion, which is a spontaneous redox reaction of materials with substances in their environment.

Compatibility & Interactions between Cathodic Protection and a Vapor Phase Corrosion Inhibitor

The Effect of the ph of Ammonum Nitrate Solution on the Susceptability of Mild Steel to Stress Corrosion Cracking (SCC) and General Corrosion

1. Introduction. Keywords Cathodic protection, Zn-Bi sacrificial anode, Cyclic hydrostatic pressure, Circuit current, Slope parameter, Hydrostatics

Online Monitoring of sub-structure

Erosion corrosion of mild steel in hot caustic. Part II: The evect of acid cleaning

RAPID MACROCELL TESTS OF ENDURAMET 2304 STAINLESS STEEL BARS

Correlation between Neutral Salt Spray (NSS) Test and Potentiostat Dynamic Test for Corrosion on Zinc Plated Steel

Performance of Nickel-Coated Manganese Steel in High-Chloride Low-Sulphate Seawater Environments

Study on Corrosion Behavior of Rebar HRB335 in NaCl Solution Ping Li

Improvement of corrosion resistance of HVOF thermal sprayed coatings by gas shroud

RAPID MACROCELL TESTS OF LDX 2101 STAINLESS STEEL BARS

Case Histories for Cased Crossings Using an Integrated Tool Approach with Long Range Guided Wave. NACE DA Conference By Joe Pikas

Ductile Iron Piles Corrosion Resistance

Reference Electrode for Monitoring Cathodic Protection Potential

A Study of Performance of Aluminium Anode by Addition of Zinc in Sea Water

Corrosion Protection for Concrete Structures in Marine Environments. D.B.McDonald, Ph.D., P.E, FACI

IPC TECHNICAL PAPER SERIES NUMBER 74 LOCALIZED CORROSION OF STAINLESS STEELS IN PAPER MACHINE WHITE WATER DAVID F. BOWERS FEBRUARY, 1979

RAPID MACROCELL TESTS OF ENDURAMET 33, ENDURAMET 316LN, and ENDURAMET 2205 STAINLESS STEEL BARS

Characterization of Oxide Film Formed on Ck45 Steel by Plasma Electrolytic Oxidation Method

Corrosion Basics. About this article

Application of Computational Modeling to Predict the Effectiveness of CP on a PCCP Transmission Pipeline

Zero Liquid Discharge Cooling Tower Treatment at CSI

Kinetic Characteristics of Different Materials used for Bolting Applications

A study on the Effect of Volatile Corrosion Inhibitors on Impressed Current Cathodic Protection

DEVELOPMENT OF ENVIRONMENTALLY FRIENDLY FORMULATION FOR CORROSION RESISTANCE OF GALVANIZED STEEL SHEET

IN SITU MONITORING OF REINFORCEMENT CORROSION BY MEANS OF ELECTROCHEMICAL METHODS

P-6. Optimization of Citric Acid Passivation for Corrosion Resistance of Stainless Steel 440C. Chi Tat Kwok 1,2 and Wen He Ding 1.

Sensors & Transducers Published by IFSA Publishing, S. L., 2017

Performance of Close Anode Cathodic Protection System Applied to a Plane Metallic Grid

Chapter 16 Corrosion and Degradation of Materials

Corrosion of mild steel and 316L austenitic stainless steel with different surface roughness in sodium chloride saline solutions

E6) Study on the Corrosion of Steel and Zinc with Flow Velocity and Corrosion Control by the Vacuum Membrane Deaeration System in Tap Water

Electrochemical Corrosion Behavior of Tubing Alloys in Simulated Space Shuttle Launch Pad Conditions

2. Wet Corrosion: Characteristics, Prevention and Corrosion Rate

Corrosion is defined in different ways, but the usual interpretation of the term is an attack on a metallic material by reaction with its

Galvanic Liquid Applied Coating for the Protection of Concrete Reinforcement. Andrea Hansen Alla Furman Marlin Hansen Angel Green Jessi Meyer

High-Temperature Cathodic Disbondment Testing Part 2: Parallel Testing

STATE OF ILLINOIS WILLIAM G. STRATTON, Governor

In 2001, the U.S. Department of. A Sacrificial Anode Retrofit Program for Existing Cast Iron Distribution Water Mains. Background

Galvanic Corrosion Between AISI304 Stainless Steel and Carbon Steel in Chloride Contaminated Mortars

KINETICS OF IRON SULFIDE AND MIXED IRON SULFIDE/CARBONATE SCALE PRECIPITATION IN CO 2 /H 2 S CORROSION

CLEANING AND PREVENTION OF INORGANIC DEPOSITS IN PLATE HEAT EXCHANGERS USING PULSATING CURRENT

Corrosion Properties of Enhanced Duplex Steel UNS S32304

Corrosion Protection of Steel Rebar in Concrete By Migrating Corrosion Inhibitors

Surface Engineering Challenges of Dissimilar Materials Joints

Monitoring Cathodic Shielding and Corrosion under Disbonded Coatings

MEASUREMENT OF STEEL CORROSION IN CONCRETE

Synergistic Effect of Tobacco and Kola Tree Extracts on the Corrosion Inhibition of Mild Steel in Acid Chloride

Cathodic Protection Influencing Factors and Monitoring

COST ACTION 534. WG 2: New system. Internal reference electrode to detect steel corrosion. CMIC Giulio Natta - Politecnico di Milano

Hydrogen Generation During the Corrosion of Carbon Steel in Oxalic Acid (U) B. J. Wiersma WSRC-TR (U)

The below identified patent application is available for licensing. Requests for information should be addressed to:

Effect of Precorrosion and Temperature on the Formation Rate of Iron Carbonate Film

Galvanic Corrosion of a Zn/steel Couple in Aqueous NaCl

Pitting susceptibility of AISI 304 stainless steel after cold rolling Olandir V. Correa a, Mara C.L. de Oliveira b, Renato A. Antunes c.

MEASURING THE EFFECTIVENESS OF MIGRATING CORROSION INHIBITORS (MCIs) BY ELECTROCHEMICAL TECHNIQUES

Roles of Alloying Elements on the Corrosion Behavior of Amorphous W Zr (15 33)Cr Alloys in 1 M NaOH Solution

FINAL REPORT: LARGE SCALE ACCELERATED CUI TEST OF E-2000 AND E-1100EG

Chapter 7a- Interpreting Polarization Curves

Re-alkalisation technology applied to corrosion damaged concrete

Characterization of the Corrosion Scenarios on the Trans-Canada Pipeline (Alberta System)

IRON CARBONATE SCALE GROWTH AND THE EFFECT OF INHIBITION IN CO 2 CORROSION OF MILD STEEL

Transactions on Modelling and Simulation vol 8, 1994 WIT Press, ISSN X

Impact of the soil resistivity on IR drop when applying a cathodic protection system with galvanic anodes on PCCP

OFFSHORE CATHODIC PROTECTION 101: WHAT IS IT AND HOW DOES IT WORK? Dick Baxter & Jim Britton

Corrosion Behaviour of aluminium alloys used in heat-exchangers Joana Catarina Videira Madeira. 1. Introduction to Aluminium Science and Technology

Dan Duke Water Conservation Technology International, Inc. Temecula, CA. Lietai Yang Corr Instruments, LLC San Antonio, TX ABSTRACT

Transcription:

ONLINE MONITORING OF CORROSION UNDER CATHODIC PROTECTION CONDITIONS UTILIZING COUPLED MULTIELECTRODE SENSORS Xiaodong Sun Corr Instruments, LLC San Antonio TX, USA ABSTRACT Real-time corrosion monitoring for carbon steel materials in simulated seawater under cathodic protection conditions was conducted, utilizing coupled multielectrode sensors. It was demonstrated that the coupled multielectrode sensor is an effective real-time tool for monitoring the effectiveness of cathodic protection and for measurement of the threshold value of the protection potential for specific equipment. Keywords: Cathodic protection, corrosion monitoring, corrosion sensor, localized corrosion, online corrosion sensor, real-time corrosion sensor, multielectrode sensor, coupled multiple electrodes. INTRODUCTION Cathodic protection (CP) is widely used to protect metallic structures and components in many industries, including infrastructure, transportation, oil and gas transmission and chemical processes. According to a recent NACE report, 1 the total estimated cost for cathodic and anodic protection in the U.S. alone in 1998 was $2.22 billion, of which the majority cost was associated with the CP. The protection provided by the CP depends on the distribution of the cathodic current density. Due to the variations in geometry of protected structures or components, or to the location of anodes, certain areas of the protected structure or component may not receive the minimum cathodic current density that is required to provide sufficient protection. Corrosion may take place in these areas and cause catastrophic failures, if not identified and mitigated at an early stage. Because corrosion in these areas is not easily detected, an effective monitoring technique is required to identify the problem at an early stage, in order to alleviate the problem in a timely manner. An online monitoring tool placed near these hard-to-protect and critical locations may provide a real-time indication of the effectiveness of the CP system. Often, the protection potential or current density is set at overly conservative values. An online monitoring tool may make it possible to automate the CP system, to enable the protection current or potential to be set at a value that is just sufficient to protect the critical areas and that, at the same time, can reduce the cost involved in the process. In addition, the values of conservative potentials or current densities for different

applications are often determined on the basis of past experiences or tests conducted under only selected conditions. These values may be either insufficient or excessive, when the conditions in the field change. Therefore, an online corrosion monitor that works under cathodic protection conditions is an ideal tool for both the real-time monitoring of the effectiveness of the CP system and for minimizing the cost of the process. Coupled multielectrode sensors have been recently used as in situ or online monitors for localized corrosion, in laboratories and industry applications 2-5. In this study, coupled multielectrode corrosion sensors were used as the online monitors under cathodic protection conditions. The experimental results of corrosion rates at different potentials and the critical protection potentials for carbon steel under simulated sea salt solution are presented. EXPERIMENTAL The sensing electrodes of the coupled multielectrode sensors were made from an annealed mild carbon steel wire (concrete rebar wire), 1.5 mm in diameter and 1.77 mm 2 in electrode surface area. Each sensor had 16 electrodes flush-mounted in epoxy. Typical sensors that were used in the experiment are shown in Figure 1. Prior to the test, surfaces of sensing electrodes for each multielectrode sensor were polished to 320 grit and rinsed with distilled water and acetone. The sensors were tested in distilled water, a simulated 3%wt of sea salt water (Vigo Importing Co., Tampa, Florida), and a solution of 3%wt sea salt plus 10 mm H 2 O 2. The experiments were conducted at 27 o C. A nanocorr TM* 50 coupled multielectrode analyzer, 5,6 manufactured by Corr Instruments (San Antonio, TX, USA), was used in the experiment. This coupled multielectrode analyzer has a high current resolution (10 12 A) and allows the measurement of coupling currents up to 50 electrodes in up to six separate sensors at the same time. Figure 2 shows that three sensors were connected to the coupled multielectrode analyzer and measured at same time. The common coupling joint of each sensor was connected to a carbon steel coil made of the same wire as the sensing electrodes and immersed in the same solution, to stabilize the potential during the normal measurements. The coupling joint of the sensor was connected to a power supply during the measurements, under cathodic or anodic polarization conditions. A stainless steel tube was used as the counter electrode for the polarization of the sensing electrodes. The potential of the common joint of each sensor (the electrochemical potential of the sensor electrodes) was measured by the multielectrode analyzer, against a saturated calomel reference electrode (SCE). A notebook computer and the factory-supplied software, CorrVisual TM*, were used in conjunction with the multielectrode analyzer. The currents from each electrode, the electrochemical potential of each sensor, and the temperature were logged at a user-specified interval (usually 20 to 120 seconds) and saved in a computer file. Processed signals, such as the localized corrosion current, the cumulative charge for each sensor, and the corrosion rate and cumulative corrosion damage (or penetration depth) for each sensor were also saved in one or more separate data files at user s choice. During the measurements, all the directly measured currents and the processed results (such as the minimum current, maximum current, mean current, current densities, corrosion rates, cumulative charges, penetration depth, and electrochemical potential), as well as the set-up parameters for data acquisition, were also dynamically available from the computer screen in both numerical and graphical forms. * nanocorr and CorrVisual are trade marks of Corr Instruments, LLC.

RESULTS AND DISCUSSIONS Sensor Responses to Different Solution Chemistries To verify the performance of the multielectrode analyzer system, it was tested with carbon steel sensors in different solutions. Figure 3 shows a typical response curve obtained from the different solutions. The sensor signal (corrosion rate) was about 1.4x10-2 micrometer/year (14 nanometer/year, or 0.00055 mil/year) in air, which is close to the lower detection limit of the sensor measurement system (1.4 nanometer/year). Upon the immersion of the sensor in distilled water, the signal increased instantaneously by 3 orders of magnitude, indicating a slight corrosion for carbon steel in distilled water (10 micrometer/year or 0.39 mil/year). As corrosion that took place on the sensor may alter the local chemistry, such as ph near the corroded electrodes, the corrosion signal gradually increased in the distilled water. Over a period of 12 hours, the corrosion rate increased, from 10 micrometer/year (0.39 mil/year) to 20 micrometer/year (0.78 mil/year). When the sensor was immersed in the simulated seawater (3%wt salt solution), the signal increased to 800 micrometer/year (31.5 mil/year) and stabilized at this value. When the sensor was immersed in the distilled water again, the corrosion rate decreased and stabilized at a value that is slightly higher than the previous value measured in the same water, suggesting that the previous value was not stabilized. Another reason for the slightly higher value in the second immersion in the same distilled water was that the sensing electrode had been corroded before the second immersion. The corrosion products, or the residue sea salt that was trapped on the sensor surface and not completely removed during the rinsing prior to the second immersion, may also have caused the increase of the corrosion rate. When the sensor was returned to the simulated seawater, the corrosion rate returned to the value measured previously in the same solution. Upon the addition of H 2 O 2 to the 3% sea salt solution (10 mm H 2 O 2 concentration), the corrosion rate increased significantly and stabilized at about 10 mm/year (394 mil/year) in a few data sampling cycles (the sampling interval was set to 2 minutes). The sensor reproduced the previous signals when it was re-immersed in the same simulated seawater or placed in air. The response curve also showed good reproducibility and stability of the sensor, whether after decreasing from a higher value or after increasing from a lower value in the simulated seawater, over the testing period. The signal measured in air showed that the sensor is extremely sensitive and capable of measuring corrosion rate near the designed lower detection limit 1.4 nanometer per year. Measurement of Critical Protection Potential Typical responses of the carbon steel sensor signals to the CP potential are shown in Figure 4. The signal for each sensor was automatically calculated by the factory-supplied software during the measurement, based on the current from the most corroding or the most active electrode among all the sensing electrodes. 2 (The signals based on the mean plus 2.5 or 3 times the standard deviation of the currents are also available from the software.) At the start of the test, the potential was controlled near the free open circuit potential, by connecting the common joints of the sensors to a separate large carbon steel coil that was made from the same wire as the sensing electrodes. The signal was 8x10-5 to 1.2x10-4 A/cm 2 (corresponding to approximately 1 mm/year) at the free open circuit potential, which is consistent with the result measured in the same solution as shown in Figure 3. The corrosion signals increased to approximately 2x10-3 A/cm 2 (corresponding to approximately 30 mm/year), when the potential was increased by approximately 0.08V. The corrosion rate gradually decreased with the decrease of potential,

sharply dropped when the potential was near, and became negative when the potential was below the critical protection potential. In this paper, the critical protection potential is defined as the highest potential at which all the carbon steel electrodes were fully protected. Figure 5 pictures the enlargement of the responses of the absolute values of the sensor corrosion signals near and below the critical protection potential. The corrosion signals stabilized at 4x10-5 A/cm 2 for sensor #2, at 3x10-6 A/cm 2 for sensor #1, and were relatively independent of the potential, when the cathodic protection potential was changed between the value slightly below the critical protection potential and -1.18 V SCE. In Figure 5, the corrosion signal was the current density measured from the most corroding or most active electrode among all the sensing electrodes in the sensor. The negative corrosion signal suggests that the most active electrode in the sensor was actually a cathode (equivalent to the most active site in a metal piece being a cathodic site) and effectively protected, when the potential was below the critical protection potential. This implies that all the electrodes in the sensor (equivalent to all areas of the metal piece) were effectively protected by the cathodic protection, when the potential was below the critical protection potential. Measurement of Corrosion Rate Under Cathodic Protection Conditions Three sensors (sensors #1, #2, and #3) were used in the measurements. Sensor #1 was cathodically polarized to approximately 0.9 V SEC, which is well below the protection critical potential. Sensor #2 was slightly anodically polarized, to simulate a faulty polarity connection in the CP system. Sensor #3 was left at the free corrosion potential, to simulate an inefficient protection from the CP system or the unprotected condition. Figure 6 shows the measured corrosion current density signals and the potentials of the three sensors during the monitoring period. In Figure 6, the corrosion current density signal for each sensor was automatically calculated by the software based on the mean value plus 2.5 times the standard deviation of the currents 2 during the measurement. The corrosion current from sensor #1 was negative throughout the monitoring period, indicating that there was no corrosion on the sensing electrodes of sensor #1. The corrosion current of sensor #3 was approximately 10-4 A/cm 2 during the first 4 days of monitoring and decreased to approximately 10-5 A/cm 2 on the 5th day. The corrosion current signal from sensor #2 was approximately 10-3 A/cm 2 throughout the monitoring period, indicating that the corrosion increased by more than one order of magnitude, when the potential was raised by approximately 0.07 V from the free corrosion potential. The slight decrease of the free corrosion potential of sensor #2 over the monitoring period was probably due to the ph increase caused by the relatively large cathodic reaction of oxygen on the stainless steel counter electrode used to anodically polarize sensor #2. At the end of the test, a large amount of rust deposit was observed at the electrochemical cell, suggesting a high ph solution. The corrosion rates for the three sensors were also available from the software during the measurement (Figure 7). The corrosion rate of the unprotected sensor sensor #2 in the first 4 days was approximately the same as the value measured in the previous measurements, which were conducted with similar sensors in the simulated seawater (Figure 2). However, the rate was slightly lower after the 5th day. The difference between the values measured in the first 4 days and the values measured after the 5 th day (Figure 7) is within the expected range of variations for localized corrosions in a given environment. The corrosion rate for sensor #1 was automatically set to the lower detection limit of the instrument because its corrosion current signal was negative, indicating that there was no corrosion. Figure 8 shows the appearance of the sensor electrodes after the monitoring period. Clearly, all the electrodes of sensor #2 (except the one with faulty connection at the location of row 3 and column 2) were severely corroded. Slight pitting corrosion can be noticed on some of the electrodes of sensor #3. No

significant pitting corrosion was observed on the electrodes of sensor #1. The result, as shown in Figure 8, is in agreement with the measured corrosion rate shown in Figure 7. In addition, Figure 7 shows that the average corrosion rate for sensor #2 was 12.7 mm/year. Hence, the total penetration depth for the most corroded electrode on sensor #2 should be 0.38 mm, after the 11 days of exposure. The measured depth of the most corroded electrode on sensor #2, as shown in Figure 8, was approximately 0.4 mm, which is in excellent agreement with the depth estimated by the coupled multielectrode sensor. CONCLUSION It was demonstrated that coupled multielectrode sensors are effective tools for real-time measurement of the critical protection potential for cathodic protection. The sensors can also be used as online tools to measure the corrosion rate under cathodic protection potentials. If placed near the critical locations of engineering components, they can be used to detect either the effectiveness or faulty conditions of the cathodic protection system in real-time. REFERENCES 1. G. H. Koch, M.P.H. Brongers, N.H. Thompson, Y. P. Virmani, and J.H. Payer, Corrosion Cost and Preventive Strategies in the United States, NACE Report, FHWA-RD-01-156, (Houston, TX: NACE, 2001). 2. L. Yang, N. Sridhar, O. Pensado, and D.S. Dunn, Corrosion, 58 (2002), p.1004. 3. L. Yang, R.T. Pabalan, L. Browning, and G.C. Cragnolino, Measurement of Corrosion in Saturated Solutions under Salt Deposits Using Coupled Multielectrode Array Sensors, CORROSION/2003, paper no. 426 (Houston, TX: NACE, 2003). 4. C.S. Brossia and L. Yang, Studies of Microbiologically Induced Corrosion Using a Coupled Multielectrode Array Sensor, CORROSION/2003, paper no. 575 (Houston, TX: NACE, 2003). 5. X. Sun, Online Monitoring of Undercoating Corrosions Utilizing Coupled Multielectrode Sensors, CORROSION/2004, paper no.04033 (Houston, TX: NACE, 2004). 6. Web site: http://www.corrinstruments.com.

Figure 1. Typical coupled multielectrode sensors used in the experiment.

Figure 2. Coupled multielectrode corrosion analyzer system used in the experiment.

Corrosion Rate (micrometer/year) 100000.00 10000.00 1000.00 100.00 10.00 1.00 Distilled Water 3%wt Sea Salt Distilled Water 3%wt Sea Salt+ 10 mm H 2 O 2 3%wt Sea Salt 1000 3937 100 394 39.4 10 13.94 0.394 0 0.0394 0 Corrosion Rate (mil/year) 0.10 Dry Air Dry Air 0.01 0.0 1.0 2.0 3.0 4.0 5.0 6.0 Time (day) 0.00394 0 0.000394 0 Figure 3. Typical responses of carbon steel sensors to the changes of solution chemistry. The signals measured in dry air (~14 nm/year) are close to the lower detection limit of the sensor system (1.4 nm/year).

1.0E-02 1.0E-03 Sensor 1 Signal Sensor 2 Signal Potential 0.1-0.1 Corrosion Signal (A/cm 2 ) 1.0E-04 1.0E-05 Critical Protection Potential: -0.72--0.74 V SCE -0.3-0.5-0.7-0.9 Potential [ V (SCE) ] 1.0E-06 Corrosion Signals Became Negative -1.1 1.0E-07 0.5 1.5 2.5 3.5 4.5 Time (day) -1.3 Figure 4. Responses of the corrosion signals (anodic current densities) of the sensors to the changes of the cathodic protection potential in a 3%wt sea salt solution. For detailed signal changes near and below the critical protection potential, see Figure 5.

1.0E-03 1.0E-04 Sensor 1 Signal Negative of Sensor 1 Signal Sensor 2 Signal Negative of Sensor 2 Signal Potential -0.5-0.55 Corrosion Signal (A/cm 2 ) 1.0E-05 1.0E-06 1.0E-07 1.0E-08 1.0E-09 Signal Positive --Corroding Sensor 2 Critical Protection Potential: -0.72 V SCE Sensor 1 Critical Protection Potential: -0.74 V SCE Signal Negative --Non-corroding -0.6-0.65-0.7-0.75-0.8-0.85 Potential [ V (SCE) ] 1.0E-10 2.1 2.2 2.3 2.4 2.5 2.6 Time (day) -0.9 Figure 5. Responses of the absolute values of the sensor corrosion signals to the changes of the cathodic protection potential near and below the critical protection potential in the 3%wt sea salt solution. The sensor corrosion signals became negative upon reaching the critical protection potential, indicating there was no corrosion on the sensing electrodes when the potential was below the critical protection potential.

Corrosion Current Signal (A/cm 2 ) 1.00E-02 1.00E-03 1.00E-04 1.00E-05 1.00E-06 1.00E-07 1.00E-08 1.00E-09 0.15 Sensor 2 Signal 0.05-0.05 Sensor 3 Signal -0.15-0.25-0.35 Negative of Sensor 1 Signal -0.45-0.55 Sensor 2 Potential -0.65 Sensor 3 Potential -0.75-0.85-0.95 Sensor 1 Potential -1.05 0 2 4 6 8 10 12 Potential [V(SEC)] Time (day) Figure 6. Corrosion current signals and the potentials of the sensors during the monitoring period. The corrosion signal from sensor #1 was negative (-6x10-6 to -1x10-5 A/cm2), indicating no corrosion was taking place on sensor #1 electrodes.

100000.000 10000.000 Sensor 2 1.60E-03 3937 1.40E-03 394 Corrosion Rate (micrometer/year) 1000.000 100.000 10.000 1.000 0.100 0.010 Sensor 3 Sensor 1 corrosion current was negative; Corrosion rate was set to lower limit by instrument 1.20E-03 39.4 1.00E-03 3.94 8.00E-04 0.394 6.00E-04 0.0394 4.00E-04 0.00394 2.00E-04 0.000394 Corrosion Rate (mil/year) 0.001 0.00E+00 0.000039 0 2 4 6 8 10 12 Time (day) Figure 7. Measured corrosion rate during the monitoring period. Sensor 1 corrosion rate was set to the lower detection limit (1.4 nm/year) by the instrument, because its current was negative, indicating there was no corrosion on the sensing electrodes.

S e n s o r 1 S e n s o r 2 S e n s o r 3 Figure 8. Appearances of the electrodes of sensors after the monitoring period. Sensor #1 electrodes were cathodically protected. Sensor #2 electrodes were anodically polarized except the shiny one that had a faulty connection (at row 3 and column 2). Sensor #3 electrodes were maintained near the free corrosion potential. The electrode outside the 4 by 4 matrix in each sensor was used as a position locator and was not part of the sensing electrodes.