Contacts. The Space. Lx Kit List. Sound Kit List. Stage Management. Health & Safety Policy

Similar documents
HIS MAJESTY S THEATRE

The Beacon Arts Centre Technical Specifications

UNDERGROUND 1 & 2 TECHNICAL INFORMATION

CASUS CIRCUS INC 198 Woodrow Rd Stanmore QLD 4514

MEDEA BASIC TECHNICAL INFORMATION 2016

PORT MACQUARIE HASTINGS COUNCIL. Glasshouse Studio. Technical Specifications. 15 nd December, 2016

Welcome. BOOKING To enquire about venue availability and arrange a site visit, please call or . Phone:

TECHNICAL SPECIFICATIONS

PRE-CONSTRUCTION (PRE-PRODUCTION) INFORMATION FOR TOURING PRODUCTIONS AND CO-PRODUCTIONS USING THE CAPITOL, HORSHAM

Odell Williamson Auditorium Technical Specifications

TECHNICAL SPECIFICATIONS

PRE-CONSTRUCTION (PRE-PRODUCTION) INFORMATION FOR TOURING PRODUCTIONS AND CO-PRODUCTIONS USING THE CAPITOL, HORSHAM

Technical Specifications

Darlington Hippodrome Technical Specification

Stage door is un-manned; access is via security code which is given to the Company Manager on arrival.

THE LOCK-UP VENUE HIRE INFORMATION

Technical Advance Form for hires to be completed no less than four weeks before load-in.

Venue details. Stage Dimensions. Clearances

TECHNICAL SPECIFICATIONS

Shoalhaven Entertainment Centre Auditorium Technical Specifications. Main Auditorium. Updated 29 January 2018

OPEN TO NEW EXPERIENCES

The International Centre. Site Induction. Construction Design & Management 2015

The International Centre. Site Induction. Construction Design & Management 2015

Gartner Auditorium. The Cleveland Museum of Art

THE WHARF TERRACES RENOVATIONS POLICY

Orchestra pit: 42-0 w x 9-0 d, extended configuration Avg.# of musicians = XX w/stands & instruments 8-4 lip overhang

VENUE AND SAFETY INFORMATION FOR SCHOOL EXCURSION

ARTIST STUDIO TECHNICAL SPECIFICATIONS BRIC HOUSE 647 FULTON ST. BKLYN NY BRIC HOUSE ARTIST STUDIO TECHNICAL SPECIFICATIONS 11/13/18 1

technical specification

Robert Blackwood Hall Planning Form

Technical Information for the Jaeb Theater located at The David A Straz, Jr. Center For the Performing Arts

LIGHTING SUPERVISOR (SOUTHBANK THEATRE)

technical theoldmarket.com specification

State Theatre. Stage floor to bottom of lowest catwalk: Curtain line to back wall: , 98-6 back of bussel

PEACOCK THEATRE TECHNICAL SPECIFICATIONS

Noise Survey. for. K & F Restaurant, 39 Camberwell Road, London SE5 0EN. Date of report: 30 th November 2012

ENHANCING WORKING ENVIRONMENTS Prevention and wellbeing at work 11/04/2018 Anne Bertrand

TECHNICAL INFORMATION

Access Statement for Murthwaite Lodges, Longsleddale.

Orchestra pit: 49-0 w x 27-0 d. Loading door: w x 8-7 h w x 8-7 h (center)

MVDC F041 Safety Inspection Checklist

Paramount Theatre Technical Information

SECTION NON-STRUCTURAL METAL FRAMING

PRODUCTION TECHNICIAN

NIGHTCLUBS APPLICATION GUIDE

How to Apply This pack contains the job description and person specification for the position of Technical Manager (Interim) at the Bush Theatre.

Loading Docks. Version 1.0 I Last Updated Date 26/02/2015 Page 1

ROPPONGI HILLS ARENA. Facility guide List of charges

Exhibitor Manual Information

LOBERO THEATRE TECHNICAL SPECIFICATIONS. Updated September,

Legal Summary SHE-037 Handbook of Business Operation in Thailand s Industrial Estate Version 2

Burley Avenue, Bristol, BS16 5PP. Asking Price: 385,000

TECHNICAL INFORMATION

EbzB Productions Your World Is Our Stage!

B. RESIDENTIAL MASTER PLUMBER $ $ $

THE DEBATING HALL. There is no crossover behind the stage but it is possible to cross around the house to make an entrance

Contractors Code of Practice

Stratford Circus Arts Centre

Goodyear Theater & Hall Information

EVENT: PLANNED VENUE: Phillips Center for the Performing Arts University Auditorium

SKIP Event Space Starrett-Lehigh Building, 601 West 26 th Street

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

Ticking Form - Lodge - 1 -

DURANTS SCHOOL FIRE EVACUATION PLAN

Concert Hall Technical Specifications University of Kentucky Singletary Center Lexington, Kentucky Revised 09/14

CINDERELLA Asia Tour

Position Description

ORGANISERS & SUPPLIERS

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Single Family, Orange, CT

technical specification

Venue Technician. Job Description Person Specification. glive.co.uk hqtheatres.com. February 2018

APPLICATION FOR FINISHED BASEMENT PERMIT

Some frequently asked questions...

Schedule C STANDARD Specifications

IV. REGULATIONS GOVERNING BOOTH DECORATION WITHIN THE TAIPEI WORLD TRADE CENTER EXHIBITION HALL

Perth Concert Hall. July Technical and Production Information.

The Great 2018 NZ International Comedy Fest at BATS Info Pack

Company s Name: GHI Warehouse Date of Risk Assessment:

PROPOSED REGULATION OF THE STATE CONTRACTORS BOARD. LCB File No. R May 4, 2004

1.5m EXTERNAL PLATFORM LIFT (rising vertically up to 1.5 metres) Information Sheet for EMS Assessors

KACHETTE. Kachette Events Manual Page 1

Health & Safety Induction for Staff, Service Users & Volunteers

Objectives. Identify hazards in the shop. Learn about protective clothing. Understand the dangers of fire, electricity, fumes, cylinders, and machines

Using petrol-driven chainsaws

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Remote-controlled flying objects are not permitted in the exhibition booths.

on as high a professional standard as possible. Collating this information and preparing staff rotas, to work around normal working hours as far as

ESTATES DEPARTMENT/ CLEANING/SERVICE LEVEL STATEMENT

MSP Modular Building System

Safety Statement Including Risk Assessment

Thank you for your interest in the post of Deputy Stage Manager at New Vic Theatre.

Garage Conversions. Technical Issues

April 28, 2018 West Georgia Jazz Festival

Rothschild Close, Woolston, Southampton, SO19 9TE

Quality specifications for my home

GENERAL STAND BUILDING REGULATIONS AND INFORMATION

Rigging Requirements

New Jersey Home Inspection - Standards of Practice

The requirements of this key result area will have been satisfactorily performed when:-

Transcription:

Administration 0117 902 0345 theatre@tobaccofactorytheatres.com Box Office 0117 902 0344 tickets@tobaccofactorytheatres.com tobaccofactorytheatres.com Raleigh Road, Southville, Bristol BS3 1TF Contacts The Space Lx Kit List Sound Kit List Stage Management Health & Safety Policy Administration: 0117 902 0345 / theatre@tobaccofactorytheatres.com Mike Tweddle, Artistic Director: mike@tobaccofactorytheatres.com David Dewhurst, Director of Operations: david@tobaccofactorytheatres.com Matthew Graham, Technical Manager: technical@tobaccofactorytheatres.com Jason King, Technician: technical@tobaccofactorytheatres.com

The Factory Theatre is a non-conventional, versatile theatre space, which has been used for performance since 1998, exciting audiences and performers alike. Often described as 'intimate' and 'raw', the space seats between 230 and 300 people and can be arranged end-on, in the round or thrust. For touring seasons the space is arranged endon unless specified otherwise in the contract. Seating plans are available from Matt Graham (Technical Manager). The box office is located in the foyer of the building on the ground floor. Height to Ceiling 3.7m Height to Grid 3.5m Width between pillars SR-SL 6.5m Due to the nature of the building there is the odd joist or pipe below these heights, please call if you think this may be a problem. The original factory floor is still in place (see picture above) and is a mixture of wood and tile. If a black floor is required then black dance floor can be laid if arranged in advance with the Technical Manager. The original floor is very porous and even a spilled glass of water can end up seeping through the floor to the restaurant below the theatre. Please inform the Technical Manager at the time of booking if your production uses any water.

The Tobacco Factory is a creative, mixed-use community building. The building has a creative and collaborative buzz about it, with several businesses within the building working together. Tobacco Factory Theatres are a part of this lager building; which can create both opportunities and also challenges. Every Sunday Tobacco Factory is home to community market, with around 40 food and craft stalls in the building car park. Between 07:00 and 16:00 loading in is restricted to the front entrance of the building, through Box Office and the Factory Theatre Bar. Once a month, Tobacco Factory extends the market into Raleigh Road. During these markets, loading in is only allowed before the market opens to the public. Please contact the Technical Manager if you think this might affect your get in. Onsite parking for Tobacco Factory Theatres is restricted to loading in only. Parking is available in the local area surrounding the theatre but please be aware of restrictions. If you would like further information or have concerns about parking please contact the Technical Manager. The Factory Theatre is based on the first floor of the Tobacco Factory. There is a small lift that will fit heavy but small objects. The lift dimensions are 1400mm x 1600mm x 2100mm Please note: The get-in involves 2 flights of stairs including a 180o turn and several double doorways with dimensions of 2100mm x 1550mm The Factory Theatre has one dressing room with a shower, toilet and seating for 18 people with a central divide to create male and female areas. There are two fixed clothes

rails and one portable rail, hangers an iron and ironing board and a washing machine and tumble dryer. There is also a small adjoining kitchenette with fridge, microwave, kettle and an assortment of cutlery, mugs and plates. The Tobacco Factory is a multi-use building and loud noise can disturb other building users above and below the theatre. If your production contains large amounts of sustained loud sound or anything that may disturb other building users, please inform the Technical Manager in advance of your arrival. Our theatre licence prohibits the use of any naked flame or pyrotechnics without the consent of the licencing authority. Please note this includes candles and smoking. An application to use naked flame or pyrotechnics must come from Tobacco Factory Theatres and can be a long process. We require a minimum of 6 weeks notice if naked flame or pyrotechnics are used in your production. Smoking is prohibited throughout the whole building, including by actors onstage. If smoking outside, please use the bins provided to dispose of cigarette butts.

Lighting is rigged using 9 IWB s. The plan shows the positions of the lighting bars and Iwb s. If required and within reason, extra bars can be erected. 8 tank traps and some floor stands are available. 1 x Etc Ion 96 ways of ETC Sensor 3 dimming consisting of 72 ways of dimming 24 thrupower / dimming /switching / hot power 15 ways of (5) Zerro 88 Alpha packs 34 Selecon Acclaim Fresnel 650W 20 Strand Patt 743 Fresnel 1000W 18 ETC Source4 Junior Profile 25/50 Size M gobo 575W 15 ETC Source4 Par + lens set 750W 4 Parcan 64 (CP62) 1000W 4 Par 16 Birdies 50W 4 Robe Robin 300 Led wash moving heads (rigged in fixed position) Effects (For a small Charge) 1 Jem ZR12-DMX smoke machine 1 Unique 2.1 Haze machine DMX 2 channels 3 source 4 fixed profiles with 19 or 50 degree lens tubes 1 x 70 degree lens tube also available 12 x Selecon Acclaim Fresnel w/ Barndoors 650W 4 x Selecon 1k Fresnel w/ Barndoors 1000W 6 x ETC Source4 Junior Profile 25/50 Size M gobo 575W 6 x Parcan 64 (CP62) 1000W

Any and all electrical equipment brought by the company for both on stage or backstage/dressing room use must have evidence of Portable Appliance Testing or cannot be used within Tobacco factory Theatres.

There is a show relay in place in the dressing rooms. The theatre has a hearing loop installed through the fixed sound set up. EM Acoustics 4 EM81 s horizontally flown (Foh) 4 Em51 s Flown (delays) 2 Em115 (subs) 6 JBL control 1 pro (Surrounds) 3 QSC Rmx 1450 amplifiers 2 QSC Rmx 850 amplifiers (Please note that the 850 s cannot drive the EM81 s or the subs ) 1 cloud amp 6 way (surrounds) 1 Behringer X32 Compact 1 S16 Stage box (+ one that feeds the amps) Playback 1 Mac Mini with Qlab 3 (pro Bundle license) 2 CD player with auto pause 1 MD players with auto pause 2 SM58LC microphones 1 SM57 microphones 2 EM81 s vertically flown 4 4 EM51 s Flown (Surrounds /delays) 1 Yamaha Stagepas 400i speakers (1 powered with mixer 1 passive) 1 QSC Rmx 1450 amplifier

The Factory Theatre has a small control room suitable for two people. The dressing rooms and backstage facilities are quick and easy to access. Access to the theatre wifi network is available in the theatre bar and dressing rooms. Please ask for the password on arrival. 1 Stonewood PSU 2 rings 4 Beltpack / headset 14 Metrodeck 1m x 2m legs to make 0.30m high decking legs to make 0.60m high decking legs to make 0.90m high decking legs to make 1.20m high decking (Please note this is not stored on site so if required, transport costs may be incurred) We have a reasonable stock of masking flats and black drapes, but please phone for any specific requirements.

The TOBACCO FACTORY THEATRE has the ultimate responsibility for the implementation of the Company s Health and Safety Policy. The Director of Operations and Technical Manager have the responsibility for ensuring that all staff are made aware of the Company s Health and Safety Policy and their responsibilities within the Policy, keeping the Policy under regular review, ensuring that any problems which arise are resolved. The Company will endeavor to assess all risks to employees. The Company also has the responsibility for the effectiveness of Health and Safety training and for ensuring that all staff are advised of the Health and Safety Policy and amendments thereto and that adequate records are maintained of all training, accidents and health hazards. It is the Director of Operation s and Technical Manager responsibility to identify potential hazards and take remedial action. It is also their responsibility to ensure that staff are briefed in the necessary safety measures and precautions, and to take action on hazards that are reported. All staff are expected to be vigilant and to report potential hazards. If any member of public or staff has an accident they must ensure that it is recorded in the Accident Book, which is located in the back bar store. The person reporting the accident must ensure that all hazards and procedures carried out are reported in the Accident Book. The Theatre has one first aid kit. It is located behind the theatre bar. A list of qualified first aiders is located next to the kit and in the dressing room and admin office. All staff have a responsibility to report or take remedial measures on any potential fire hazard. All staff should acquaint themselves with the Emergency Evacuation

Procedures, which are displayed in all offices, as well as the use of the relevant fire extinguishers. Any queries should be directed to the Director of Operations. Smoking is prohibited throughout the whole building. People who wish to smoke must smoke outside. Please use the bins provided to dispose of the cigarette butts. Technical staff must ensure that no untrained employee is allowed to operate any power tool that maybe considered dangerous. No person under 18 years is allowed to operate or clean such tools without adequate training and constant supervision. The entire electrical installation of Tobacco Factory Theatres is to be inspected at yearly intervals by a competent electrical contractor. Any faults arising in the meanwhile are to be brought to the immediate attention of the Technical staff. All portable electrical appliances must be inspected at yearly intervals and serviced as necessary so not to cause danger to users. Users of any portable electrical equipment who notice any defect in the equipment must report the defect immediately to the Technical staff, who must ensure that it is removed from use and either repaired or disposed of. It is the duty of every individual to take every reasonable care of the Health and Safety of themselves and other persons who may be affected by their acts or omissions at work. It is also their duty to co-operate with their employers in achieving compliance with the HEALTH AND SAFETY WORK ACT 1999. A copy of this act is displayed in the admin office. This policy statement will apply to all persons working within the Theatre, whether or not they are contractually employed by The Tobacco Factory Arts Trust. Review Date: 01.01.17