Discipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9

Similar documents
KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana

Winmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date

Prakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat

Superintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal

Nichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka

ENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka

Discipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on

Discipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5

Deep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date

Nexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka

Haryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date

Lake Huron Water Treatment Plant Mineral Report

Lake Huron Water Treatment Plant Mineral Report

French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 6/9/2015

Environment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra

Environment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand

Madhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh

Mahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management

Detroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014

RECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed

Atmy Analytical Labs Pvt. Ltd., I-38, DLF Industrial Area, Phase-1, Faridabad, Haryana. Discipline Chemical Testing Issue Date

Appendix U. Mapping of Water Quality Concentration Contours across the Province

Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003

ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report

National Association of Testing Authorities, Australia SCOPE OF ACCREDITATION

ARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report

Central Institute of Fisheries Technology, Matsyapuri P.O., Willingdon Island, Cochin, Kerala. Discipline Chemical Testing Issue Date

Schedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).

GLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

QUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;

462 - Solids, Total Dissolved 630 mg/l

Appendix C1: Batch Kinetics Tests

Point wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II)

State of Nevada Department of Conservation and Natural Resources Division of Environmental Protection Laboratory Scope of Accreditation

2019 Microbac Laboratories Inc. Ohio Valley Division

Panasonic India Pvt. Ltd.

ENVIRONMENTAL QUALITY STANDARDS REGULATIONS, 1999.

Submitted by: M/s Panasonic India Ltd

EPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)

SPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan

Environmental Protection Agency

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

As a reminder, continued participation in the Ecology Lab Accreditation Program requires the lab to:

Appendix I. Agreement on National Environmental Standards of Lao PDR, 2009

CERTIFICATE OF ANALYSIS

ANALYTES available for testing

TE Laboratories Ltd.

Appendix C: Water Quality Data

CERTIFICATE OF ANALYSIS

Chapter 2 LEGISLATIVE FRAMEWORK

Independent Analytical Supplies Ltd (Trading as) IAS Laboratories

APPENDIX I. LAMPIRAN I - RKL DAN RPL KEGIATAN TERPADU PROYEK PENGEMBANGAN TANGGUH LNG i

MECON LIMITED RANCHI , INDIA

Schedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent

In the fall of 2008, Barr and PolyMet identified four sources of historical Colby Lake water quality data. Those sources are listed below:

DETERMINING APPROPRIATE DRINKING WATER CHEMICAL AND PHYSICAL MONITORING GUIDELINES

SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015)

Magino Project Environmental Impact Statement. Technical Support Document Environmental Monitoring Plan

Appendix C Aquatic Environment - Photographs and Tables

um"ts: m1 1grams per rt1er (mg./l)

Abuja, May 2008

CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT

NEILSON RESEARCH CORPORATION

Jacqueline Ho, Mackenzie Valley Land and Water Board

MECON LIMITED RANCHI , INDIA

CALA Directory of Laboratories

National Accreditation Board for Testing and Calibration Laboratories. (A Constituent Board of Quality Council of India) CERTIFICATE OF ACCREDITATION

Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014

Discipline Chemical Testing Issue Date Certificate Number T-2133 Valid Until Last Amended on

M/s. NILAWAR LABORATORIES, NAGPUR

Report Transmission Cover Page

A. Water sampling and analysis

Amol Pharmaceuticals Pvt. Ltd. (Analytical Division), E1-362, Sitapura Industrial Area, Jaipur, Rajasthan

CALA Directory of Laboratories

West Virginia Department of Environmental Protection hereby certifies Microbac - Ohio Valley Division

Dublin City Council. Central Laboratory, Eblana House, Marrowbone Lane, Dublin 8. Testing Laboratory Registration number: 079T

Statewide Characterization of Oklahoma s Major Aquifers

2014 ASSINIBOINE RIVER MONITORING REPORT

CERTIFICATE OF ANALYSIS

Raw Potable Well Water Analysis: Grid Water Analysis: 2009 & 2016

CERTIFICATE OF ANALYSIS REVISED REPORT

Alkalinity: An Important Parameter in Assessing Water Chemistry

SABS Water Check. Inorganic Chemical proficiency testing provider for water laboratories. NLA 20 September 2011

ENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS

Final Report WP-225. WatR Pollution Study. Open Date: 10/18/13. Close Date: 12/02/13. Report Issued Date: 12/04/13

Statistics valid as of January 2004.

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Schedule of Accreditation

CATEGORY 1 & 2 TRADE WASTE QUALITY LIMITS. The temperature shall not exceed 28 degrees Celsius.

CANADA BRITISH COLUMBIA WATER QUALITY MONITORING AGREEMENT

CERTIFICATE OF ANALYSIS

The following table summarizes the average test results for the three tests conducted by ORTECH and the corresponding emission criteria:

STATE OF CONNECTICUT

Our country, our future S2 CHEMISTRY DURATION: 2 HOUR

ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA

State of Utah. Department of Health Environmental Laboratory Certification Program. Certification is hereby granted to

Drinking Water Quality and Compliance SaskWater Melville Water Supply System 2017 Notification to Consumers

AIR, WATER AND METEOROLOGICAL MONITORING JUNE 2018 PINE DALE MINE, BLACKMANS FLAT

Transcription:

Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 % Phosphorus IS 1493: 1981 (RA 2006) 0.02 % to 0.1 % Sulphur IS 1493: 1981 (RA 2006) 0.012 % to 0.02 % Loss of Ignition IS 1493: 1959 (RA 2001) 0.5 % to 15 % Manganese IS 1493: 1959 (RA 2001) 0.1 % to 2 % Bulk density IS 5842: 1986 (RA 2014) 1 g/cc to 10 g/cc 2. Manganese Ore Manganese IS 1473: 2004 (RA 2008) 5 % to 50 % Manganese dioxide IS 1473: 2004 (RA 2008) 2 % to 40 % Silicon IS 1473: 2004 (RA 2008) 0.5 % to 15 % Iron IS 1473: 2004 (RA 2008) 1 % to 40 % Aluminum IS 1473: 2004 (RA 2008) 0.5 % to 10 % Phosphorus IS 1473: 2004 (RA 2008) 0.01 % to 0.1 % Sulphur IS 1473: 2004 (RA 2008) 0.01 % to 0.2 %

Last Amended on - Page 2 of 9 3. Bauxite Ore Aluminum IS 2000 (Part 3): 1985 (RA 2006) 1 % to 90 % Silicon IS 2000 (Part 2): 1985 (RA 2006) 0.5 % to 20 % Loss of Ignition IS 2000 (Part 1): 1985 (RA 2006) 0.5 % to 30 % Titanium IS 2000 (Part 5): 1985 (RA 2006) 0.5 % to 12.0 % Ferric Oxide IS 2000 (Part 4): 1985 (RA 2006) 1 % to 35.0 % 4. Limestone & Dolomite Loss of Ignition IS 1760 (Part 1): 1991 (RA 2001) 1 % to 50 % Silicon IS 1760 (Part 2): 1991 (RA 2001) 0.5 % to 15 % Ferric Oxide IS 1760 (Part 3): 1991 (RA 2001) 0.2 % to 2 % Calcium IS 1760 (Part 3): 1991 (RA 2001) 0.5 % to 40 % Magnesium IS 1760 (Part 3): 1991 (RA 2001) 0.2 % to 40 % Aluminum IS 1760 (Part 3): 1991 (RA 2001) 0.2 % to 5.0 % II. AIR, GASES & ATMOSPHERE 1. Stack Monitoring Particulate matter IS 11255 (Part 1): 1985 (RA 2003) 1.0 mg/nm 3 to 1000 mg/nm 3 Oxides of Sulphur IS 11255 (Part 2): 1985 (RA 2003) 3.0 mg/nm 3 to 500 mg/nm 3 Oxides of Nitrogen IS 11255 (Part 7): 2005 (RA 2012) 3.0 mg/nm 3 to 400 mg/nm 3 2. Ambient Air Quality Monitoring Particulate Matter (Size less than 10µm) or PM10 IS 5182 (Part 4): 1999 (RA 2010) 1.0 µg/m 3 to 1000 µg/m 3

Last Amended on - Page 3 of 9 Ambient Air Quality Monitoring Particulate Matter (Size less than 2.5µm) or PM 2.5 USEPA 2001 1.0 µg/m 3 to 500 µg/m 3 Sulphur Dioxide IS 5182 (Part 2): 2001 (RA 2012) 4.0 µg/m 3 to 200µg/m 3 (SO 2) µg/m 3 Nitrogen Dioxide IS 5182 (Part 6): 2006 (RA 2012) 6.0 µg/m 3 to 200 µg/m 3 (NO 2) µg/m 3 3. Ambient Noise Monitoring Ambient Noise IS 9989: 1981 (RA 2008) 35 dba to 100 dba III. WATER 1. Potable and Drinking Water ph Page. 4-92 to 4-96 1 to 14 Total Hardness APHA (22 nd Edition) 2340 C Page. 2-44 to 2-46 Calcium Page. 3-67 to 3-68 Magnesium Page. 3-84 Chloride Page. 4-72 to 4-73 Total Alkalinity APHA (22 nd Edition) 2320 B Page. 2-34 to 2-36

Last Amended on - Page 4 of 9 Potable and Drinking Water Conductivity APHA (22 nd Edition) 2510 B Page. 2-54 1 µs/cm to 20000 µs/cm Total Dissolved Solids APHA (22 nd Edition) 2540 C Page. 2-65 4 mg/l to 10000 mg/l Sulphate APHA (22 nd Edition) 4500 E Page. 4-1-90 to 4-192 Fluoride APHA (22 nd Edition) 4500 D Page. 4-87 to 4-88 0.1 mg/l to 1.50 mg/l Nitrate APHA (22 nd Edition) 4500 Page. 4-125 to 4-127 0.1 mg/l to 10 mg/l Nitrite Iron Turbidity Sodium Potassium Boron Total suspended solids Page. 4-120 to 4-121 Page. 3-77 to 3-80 APHA (22 nd Edition) 2130 B Page. 2-13 to 2-15 Page. 3-97 to 3-98 Page. 3-87 to 3-88 Page. 4-25 to 4-26 APHA (22 nd Edition) 2540 D Page. 2-66t o 2-67 0.1 mg/l to 20 mg/l 0.02 mg/l to 50 mg/l 0.01 NTU to 100 NTU 0.1 mg/l to 1000mg/l 0.1 mg/l to 100 mg/l 0.02 mg/l to 10 mg/l

Last Amended on - Page 5 of 9 Potable and Drinking Water Total Solids APHA (22 nd Edition) 2540 B Page. 2-64 Chromium APHA (22 nd Edition) 2540 B Page. 2-64 0.1 mg/l to 10 mg/l 2. Waste Water ph Page. 4-92 to 4-96 1 to 14 Total Hardness Calcium Magnesium Chloride Total Alkalinity Conductivity Total Dissolved Solids Sulphate Fluoride APHA (22 nd Edition) 2340 C Page. 2-44 to 2-46 Page. 3-67to 3-68 Page. 3-84 Page. 4-72 to 4-73 APHA (22 nd Edition) 2320 B Page. 2-34 to 2-36 APHA (22 nd Edition) 2510 B Page. 2-54 APHA (22 nd Edition) 2540 C Page. 2-65 APHA (22 nd Edition) 4500 E Page. 4-190 to 4-192 APHA (22 nd Edition) 4500 D Page. 4-87 to 4-88 1 mg/l to 25000 mg/l 1 mg/l to 25000 mg/l 1 µs/cm to 100000 µs/cm 1 mg/l to 100 mg/l 0.05 mg/l to 10.0 mg/l

Last Amended on - Page 6 of 9 Waste Water Nitrate APHA (22 nd Edition) 4500 E Page. 4-125 to 4-127 0.1 mg/l to 250 mg/l Nitrite Iron Turbidity Dissolved Oxygen Sodium Potassium Boron Chemical oxygen Demand Biological oxygen Demand Oil & Grease Total solids Page. 4-120 to 4-121 Page. 3-77 to 3-80 APHA (22 nd Edition) 2130 B Page. 2-13 to 2-15 APHA (22 nd Edition) 4500N C Page. 4-139 to 4-140 Page. 3-97 to 3-98 Page. 3-87 to 3-88 Page. 4-25 to 4-26 APHA (22 nd Edition) 5220 D Page. 5-20to 5-21 APHA (22 nd Edition) 5210 B Page. 5-05 to 5-10 APHA (22 nd Edition) 5520 B Page. 5-40 to 5-41 APHA (22 nd Edition) 2540 B Page. 2-64 0.1 mg/l to 50 mg/l 0.02 mg/l to 100 mg/l 0.01 NTU to 500 NTU 1.00 mg/l to 8.00 mg/l 1 mg/l to 500 mg/l 0.02 mg/l to 10 mg/l 2 mg/l to 80000 mg/l 4 mg/l to 40000 mg/l 5 mg/l to 100 mg/l

Last Amended on - Page 7 of 9 Waste Water Total suspended solids APHA (22 nd Edition) 2540 D Page. 2-66 to 2-67 IV. BUILDING MATERIALS 1. Soil Moisture Content (%) IS 2720 (Part 18): 1992 (RA 2011) 1 % to 50 % ph IS 2720 (Part 26): 1987 (RA 2011) 0.1 to 14.0 Conductivity IS 14767: 2000 (RA 2010) 1 µs/cm to 1000 µs/cm Organic Matter (%) IS 2720 (Part 22): 1972 (RA 2010) 1 % to 25 % V. POLLUTION & ENVIRONMENT 1. Effluents ph Page. 4-92 to 4-96 Total Hardness APHA (22 nd Edition) 2340 C Page. 2-44 to 2-46 1 to 14 1 mg/l to 25000 mg/l Calcium Magnesium Chloride Total Alkalinity Conductivity Page. 3-67to 3-68 Page. 3-84 Page. 4-72 to 4-73 APHA (22 nd Edition) 2320 B Page. 2-34 to 2-36 APHA (22 nd Edition) 2510 B Page. 2-54 1 mg/l to 25000 mg/l 1 µs/cm to 100000 µs/cm

Last Amended on - Page 8 of 9 Effluents Total Dissolved Solids APHA (22 nd Edition) 2540 C Page. 2-65 Sulphate Fluoride Nitrate Nitrite Iron Turbidity Dissolved Oxygen Sodium Potassium Boron Chemical oxygen Demand APHA (22 nd Edition) 4500 E Page. 4-190 to 4-192 APHA (22 nd Edition) 4500 D Page. 4-87 to 4-88 APHA (22 nd Edition) 4500 E Page. 4-125 to 4-127 Page. 4-120 to 4-121 Page. 3-77 to 3-80 APHA (22 nd Edition) 2130 B Page. 2-13 to 2-15 APHA (22 nd Edition) 4500N C Page. 4-139 to 4-140 Page. 3-97 to 3-98 Page. 3-87 to 3-88 Page. 4-25 to 4-26 APHA (22 nd Edition) 5220 D Page. 5-20to 5-21 1 mg/l to 100 mg/l 0.05 mg/l to 10.0 mg/l 0.1 mg/l to 250 mg/l 0.1 mg/l to 50 mg/l 0.02 mg/l to 100 mg/l 0.01 NTU to 500 NTU 1.00 mg/l to 8.00 mg/l 1 mg/l to 500 mg/l 0.02 mg/l to 10 mg/l 2 mg/l to 80000 mg/l

Last Amended on - Page 9 of 9 Effluents Biological oxygen Demand APHA (22 nd Edition) 5210 B Page. 5-05 to 5-10 4 mg/l to 40000 mg/l Oil & Grease APHA (22 nd Edition) 5520 B Page. 5-40 to 5-41 5 mg/l to 100 mg/l Total solids APHA (22 nd Edition) 2540 B Page. 2-64 Total suspended solids APHA (22 nd Edition) 2540 D Page. 2-66 to 2-67 -X-X-X-X-X-X-X-X-X-X-X-X-X-X-