Mahabal Enviro Engineers Pvt. Ltd. Pollution monitoring, Engineers & Contractors in Environmental Management
|
|
- Shon Williams
- 5 years ago
- Views:
Transcription
1 PROPOSED RESIDENTIAL CUM COMMERCIAL PROJECT WITH MCGM PARKING LOT, AT LOWER PAREL, MUMBAI, MAHARASHTRA GROUND WATER ANALYSIS October, 2017 Parameter Units Sample 1 Source Location Date of collection of sample 12/10/2017 Remark-Grab/Composite Grab Sample collected by Lab Thane Limits Colour Hazen 3 5 Hazen Odour Unobjectionable Taste Agreeable ph Turbidity NTU NTU Alkalinity mg/l mg/l Total Hardness mg/l mg/l Total Dissolved Solids mg/l mg/l Chloride mg/l mg/l Calcium mg/l mg/l Magnesium mg/l 50 mg/l Sulphate mg/l mg/l Copper mg/l ND 0.05 mg/l Nitrate mg/l mg/l Fluoride mg/l ND 1.00 mg/l Phenolic Compound mg/l ND mg/l Mercury mg/l ND mg/l Cadmium mg/l ND 0.01 mg/l Arsenic mg/l ND 0.05 mg/l Lead mg/l ND 0.05 mg/l Cyanide mg/l ND - mg/l Zinc mg/l ND 5 mg/l Iron mg/l ND 0.3 mg/l Hexavalent Chromium mg/l ND 0.05 mg/l Anionic Detergent mg/l ND 0.2 mg/l Bacteriological Test mg/l M.P.N per 100 ml <3 10/100ml per100ml E-Coli per 100 ml <2 10/100ml per100ml ND: Not detectable
2 AMBIENT AIR MONITORING REPORT October, 2017 Location No. Unit P1 Location Details Project Site Date of Survey 12/10/2017 Duration of survey Hr 24 Temperature Max. / Min. 0 C 40/26 Relative Humidity Max. / Min. % 68/41 Lab Thane Wind Speed Average Km/hr 7.2 Ref. No. NAAQMS Units Respirable Particulate Matter (PM)10 μg/nm μg/m 3 Respirable Particulate Matter (PM)2.5 μg/m μg/m 3 Sulphur Dioxide (SO2) μg/m μg/m 3 Oxides of Nitrogen (NOX) μg/m μg/m 3 NAAQMS: National Ambient Air Quality Monitoring Standard. The above parameters of ambient air are within the limits.
3 NOISE MONITORING REPORT October, 2017 Location No. 1 Details Project Site Lab Thane Date of Survey 12/10/2017 Ref. No. A - human ear Fast A - human ear Fast NAAQS Units Day Time db(a) Leq Night Time db(a) Leq NAAQS: National Ambient Air Quality Standards Day Time: Morning 6 AM to 10 PM Night Time: 10 PM to 6 AM
4 SOIL ANALYSIS REPORT October, 2017 Parameter Short Name Unit Sample Source At Project site Soil Date of collection of sample 12/10/2017 Remark Grab / Composite Grab ph 7.4 Moisture % 4.0 Organic Carbon TOC % 3.1 Available Nitrogen N2 Kg/ha 49.2 Available Phosphorus PO4 Kg/ha 13.6 Chloride Cl mg/kg 40.8 Sulphate SO4 mg/kg 18.5 Copper Cu mg/kg 3.4 Zinc Zn mg/kg 3.0 Lead Pb mg/kg ND Cadmium Cd mg/kg ND Total Chromium Cr mg/kg ND The above parameters of Soil analysis are within the limits.
5 . NOISE MONITORING REPORT NEAR DG SET October, 2017 Location No. 1 Details Near D.G. SET Date of Survey 12/10/2017 Lab Ref. No. Thane 10:30 MoEF Units A - human ear Fast Day Time db(a) Leq A - human ear Fast Night Time - 70 db(a) Leq MoEF: Ministry of Environment & Forests All parameters of Noise Level at distance of one meter from D.G. Set are within the permissible limit. Day Time: Morning 6 AM to 10 PM Night Time: 10 PM to 6 AM
6 PROPOSED EXPANSION OF RESIDENTIAL CUM COMMERCIAL PROJECT WITH MCGM DG SET STACK MONITORING REPORT OCTOBER 2017 Stack Identification No. Unit Stack-1 Attached to D.G.SET Capacity 500 kva Date of Survey Checked DAP Material of Construction M.S. Stack Height m 4.5 Lab Thane Stack Shape at Top Round Ref. No. Stack Diameter at sampling point m 0.25 Type of Fuel Diesel Fuel Consumption l/hr 81 Flue Gas Temperature o C 375 Flue Gas Velocity m/sec 15.8 Flue Gas Quantity m 3 /hr 2792 MPCB Consent Limit Suspended Particulate Matter (SPM) mg/nm Sulphur Dioxide Kg/day 0.63 The above parameters of Stack emission are within the limits.
KKB Micro Testing Labs Pvt. Ltd., , 2 nd Floor, Tarun Plaza, NFC Main Road, Krishna Nagar Colony, Moula Ali, Hyderabad, Telangana
Last Amended on - Page 1 of 7 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Monitoring RSPM ( PM 10) IS 5182 (Part 23): 2006 (RA ) 5 µg/m 3 to 750 µg/m 3 PM 2.5 SOP 11 dated 17.11.2014 12.5 µg/m 3 to 500 µg/m
More informationGLOBAL TECH. ENVIRO EXPERTS PVT. LTD. (FORMERLY GLOBAL EXPERTS) An ISO-9001:2008 Certified Company
STACK MONITORING RESULT Name of Industry & Address Date of Monitoring 08-11-17 Date of Analysis 12-11-17 Reference No Stk-05/11/17 M/s SHIVA CEMENT LIMITED: Sl. No. Parameters Cement Mill 1 Kiln (Result)
More informationNichrome Testing Laboratory and Research Private Limited, No nd Main, German Hospital Road, Narayanpur, Dharwad, Karnataka
Last Amended on - Page 1 of 9 I. WATER 1. Drinking Water Colour 2120 B 1 to 100 Hazen Units ph 4500 H+, B 3 to 12 Electrical conductivity 2510 B 5 to 10,000 µs/cm Turbidity 2130 B 1 to 100 NTU Chloride
More informationMECON LIMITED RANCHI , INDIA
ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF JULY 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 SEPTEMBER, 2011
More informationPrakruti Environmental Engineers (Environmental Laboratory), 1, Utkanth Society, B/H Alkapuri Club, Alkapuri, Vadodara, Gujarat
Prakruti Environmental Engineers (Environmental ), Last Amended on - Page 1 of 7 I. WATER 1. Water (Ground Water/ Surface Water/ Drinking Water/ Treated Water) ph APHA 4500-H + B, Temperature APHA 2550
More informationAnnex 7.1 National Ambient Air Quality Standards for Nepal, 2003
Annex 7.1 National Ambient Air Quality Standards for Nepal, 2003 Parameters Units Averaging Time TSP (Total Suspended Particulars) Concentration in Ambient Air, maximum Test method µg/m 3 Annual - 24-hours*
More informationPoint wise compliance for the conditions stipulated in Environmental Clearance of (Phase- I & II)
SIX MONTHLY ENVIRONMENTAL COMPLIANCE STATUS REPORT (PERIOD : OCT, 2017 to MARCH, 2018) Ref: J-13011/23/2007-IA-II (T) Dated: 17/07/2007 (as amended in the Year, 2013 & 2014) and J-13011/46/2007-IA-II (T)
More informationMECON LIMITED RANCHI , INDIA
ORISSA MINING CORPORATION LIMITED BANGUR CHROMITE MINING PROJECT POST CLEARANCE ENVIRONMENTAL MONITORING REPORT FOR THE MONTH OF SEPTEMBER 2011 MECON LIMITED RANCHI 834 002, INDIA 11.S2.2011 OCTOBER, 2011
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3553 Valid Until Last Amended on - Page 1 of 9
Last Amended on - Page 1 of 9 I. ORES & MINERALS 1. Iron Ore Total Iron IS 1493: 1981 (RA 2006) 10 % to 70 % Silicon IS 1493: 1981 (RA 2006) 0.5 % to 25 % Aluminum IS 1493: 1981 (RA 2006) 0.5 % to 20 %
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3790 Valid Until Last Amended on - Page 1 of 5
Last Amended on - Page 1 of 5 AT LABORATORY I. WATER 1. Drinking Water, Colour IS 3025 (Part 4): 1983 (RA 2002) Spectrometer method 2120C Odour IS 3025 (Part 5): 1983 (RA 2002) 2 Hazen units to 500 Hazen
More informationNexus Test Labs Pvt. Ltd., No. 29, 2 nd Floor, 3 rd Cross, Singaiahnapalya, Mahadevapura, Bangalore, Karnataka
Certificate Number TC-5069 (in lieu of T-3362 & T-3363) Page 1 of 17 Range ing / BIOLOGICAL TESTING I. WATER 1. Drinking Water R.O. Water, Ground Water, Surface Water, Treated Water. 2. Waste Water/ Effluents
More informationSuperintendence Company of India Private Limited, Plot Y-23, Block-EP, Sector-V, Salt Lake City, Kolkata, West Bengal
Last Amended on - Page 1 of 16 I. WATER 1. Drinking Water ph IS 3025 (Part 2): 2004, Colour APHA (22 nd Edition) 2120 B: Turbidity (NTU) IS 3025 (Part 10): 1984 Residual, Free Chlorine IS 3025 Part 26/1986
More informationRECOMMENDED SCOPE OF ACCREDITATION (For Testing Laboratories) * Test Method / Standard against which tests are performed
Sl Product / Material of test 1 Wastewater Colour, true colour units, 2 Turbidity, NTU 3 Total dissolved solids mg/1, IS-3025 (Part 4) -1983 2005: 2120 /C IS-3025 (Part 10)-1984 2005: 2130/B IS-3025 (Part
More informationWinmet Technologies Private Limited, Plot No. E-65, Site-IV, UPSIDC, Greater Noida, Uttar Pradesh. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 8 I. AIR, GASES & ATMOSPHERE 1. Ambient Air PM 2.5 PM10 (RSPM) WMN/ENV/AIR/03, Issue no. 1 dated 01.10.2013 IS: 5182 (Part -23)-2006, 10 500 µg/m 3 10 1000 µg/m 3 Suspended
More informationENVIRONMENTAL AUDIT REPORT [STATEMENT] CONSTRUCTION WORK [ HALF YEARLY ] PERIOD OCTOBER 2012 TO MARCH 2013 FOUNDRY PARK
ENVIRONMENTAL AUDIT REPORT [STATEMENT] ON CONSTRUCTION WORK [ HALF YEARLY ] PERIOD OCTOBER 2012 TO MARCH 2013 FOUNDRY PARK HOULI BAGAN, RANIHATI AMTA ROAD, HOWRAH Prepared by: FOUNDRY CLUSTER DEVELOPMENT
More informationPanasonic India Pvt. Ltd.
Panasonic India Pvt. Ltd. December-2014 FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana 1 Details of Environmental Monitoring INTRODUCTION M/s Panasonic India Pvt Ltd granted its Environmental
More informationSubmitted by: M/s Panasonic India Ltd
Environmental Monitoring Report (June-2014) FOR Industrial Building of Panasonic India Ltd At Jhajjar, Haryana Submitted by: M/s Panasonic India Ltd INDUSTRIAL PLOT NO-1, VILLAGE- BID DADRI JHAJJAR (HARYANA)
More informationDiscipline Chemical Testing Issue Date Certificate Number T-3617 Valid Until Last Amended on
Last Amended on 18.01.2016 Page 1 of 8 I. WATER 1. Potable, Domestic and Bore-well Water ph IS 3025 (Part 11): 1983 Electrometric Method Colour IS 3025 (Part 4): 1983 Specific Conductance IS 3025 (Part
More informationENVIPRO Laboratories, 2nd Floor, Sy. No. 63/4, Site No. 5, P&T Layout Road, Ashwath Nagar, Srigandhada Kaval, Sunkadakatte, Bangalore, Karnataka
Certificate Number TC-6325 Page 1 of 5 Range ing / CHEMICAL TESTING I. WATER 1. Surface Water, Ground Water, Industrial Water, Drinking Water, Irrigation Water, Water From Purifiers & Swimming Pool Water
More informationTolerance and Classification
Tolerance and Classification As per ISI-IS: 2296-1982, the tolerance limits of parameters are specified as per classified use of water (Table 1,2,3,4,5 below) depending on various uses of water. The following
More informationAppendix I. Agreement on National Environmental Standards of Lao PDR, 2009
Appendix I Agreement on National Environmental Standards of Lao PDR, 2009 I.1 DRINKING WATER QUALITY STANDARDS Lao PDR current standards for drinking water of the Lao PDR are provided below for reference.
More informationEnvironment Laboratory, Central Mine Planning and Design Institute Limited, Gondwana Place, Kanke Road, Ranchi, Jharkhand
Environment, Central Mine Planning and Design Institute Last Amended on - Page 1 of 9 1. POLLUTION & EFFLUENTS 1. Effluent / Waste Water Ammonical Nitrogen Free Ammonia IS 3025 (Part 34):1988, Nessler
More informationSIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015)
SIX MONTHLY REPORT OF EMP CLEARANCE J11015/536/2008- IA-II(M) FOR THE PERIOD OCTOBER-2014 TO MARCH-2015 (1 ST June 2015) ARA OCP (ARA SARUBERA GROUP OF MINES) KUJU AREA CENTRAL COALFIELDS LIMITED (A Miniratna
More informationAPPENDIX I. LAMPIRAN I - RKL DAN RPL KEGIATAN TERPADU PROYEK PENGEMBANGAN TANGGUH LNG i
APPENDIX I Table 1 Emission Standards from Flare, Gas Turbine, Boiler, Acid Gas Incinerator and Internal Combustion Engine... 1 Table 2 n-hazardous Waste Incinerator Standard... 3 Table 3 Hazardous Waste
More informationSCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS
SCHEDULE I LIST I GENERAL STANDARDS AND CRITERIA FOR THE DISCHARGE OF INDUSTRIAL EFFLUENTS INTO INLAND SURFACE WATERS UNIT TOLERANCE LIMIT NO. PARAMETER TYPE OF LIMIT VALUES 01 Total suspended solids mg/1,
More informationANNEXURE- II Proposed TOR
ANNEXURE- II Proposed TOR Annexure II Terms of Reference for EIA for Setting up of Ligno-Cellulosic Biomass based second generation (2G) Ethanol Bio-Refinery with capacity of 100 KLPD at village-sainjani,
More informationEnvironment Laboratory, Central Mine Planning & Design Institute Limited, Regional Institute-IV, Kasturba Nagar, Jaripatka, Nagpur, Maharashtra
Last Amended on - Page 1 of 9 I. POLLUTION & ENVIRONMENT 1 Effluent / Waste Water (As per EPA 2000) Ammonical Nitrogen / Free Ammonia IS 3025(Part 34):1988, RA 2009, Nessler s Method 0.02-2.5 mg/l, B.O.D
More informationENVIRONMENTAL MONITORING REPORT BASED ON DATA GENERATED FROM OCTOBER 2016 MARCH 2017 FOR OCL INDIA LIMITED At/Po: RAJGANGPUR, District: SUNDARGARH, ODISHA AT LANJIBERNA LIMESTONE & DOLOMITE MINES PROJECT
More informationHagler Bailly Pakistan Associated with PA Consulting Group
Associated with PA Consulting Group Technical, Management, and Economic Counsel 330 MW Coal-Fired Power Plant in Energy Park, Block II Thar Coalfields Environmental and Social Impact Assessment Final Report
More informationARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report
Sampling Locations Near Bromine, Plant/Near ETP. Ambient Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB October November December Avg. 1 PM 10 µg/m 3 100 53 63 70 62 2 PM2.5 µg/m
More informationENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS
ENVIRONMENTAL GUIDANCE NOTES: ENVIRONMENTAL STANDARDS AND LIMITS Disclaimer: The information contained in this communication document is intended solely for the use of guidance cannot be considered as
More informationARCHEAN CHEMICAL INDUSTRIES PRIVATE LIMITED. Ambient Air Monitoring Report
Sampling Locations- Near Bromine, Plant/Near ETP. Ambient Air Monitoring Report Sr. No. Parameters Unit (SI) Specification/SPCB 1 PM 10 µg/m 3 100 61 71 59 63.66 2 PM2.5 µg/m 3 60 16 24 18 19.33 3 Sulphur
More informationMadhya Pradesh Waste Management Project Laboratory, Plot No. 104, Industrial Area No. II, Pithampur, Dhar, Madhya Pradesh
Madhya Pradesh Waste Management Project, Certificate Number TC-5022 (in lieu of T-2449) Page 1 of 8 CHEMICAL TESTING I. POLLUTION AND ENVIRONMENT 1. Waste Water (Effluent & Sewage) ph APHA 22nd Edition,
More informationCERTIFICATE OF ANALYSIS
1 CERTIFICATE OF ANALYSIS ATTENTION: Water Purification Solutions DATE: 29 November 2018 1. GENERAL: Table-1: Tierkloof Borehole & Product - Sampled 1 November 2018 Results expressed in parts per million
More informationEPA Primary. (mg/l as CaCO3) (mg/l as CaCO3)
NORTH TEXAS MUNICIPAL WATER DISTRICT - Wylie Water Analysis Jan-2018 Mineral Analysis Raw Treated Standards Residue on Evaporation 412 456 500 1000 Silica (SiO2) 3.63 3.41 Iron (Fe) 0.378 0.259 0.3 0.3
More informationQUESTIONNAIRE FOR GENERAL WTP REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : groundwater (well pit); urban wastewater;
REQUESTED DATA FOR THE WATER TREATMENT PLANT (WTP) - Application : ENVIRONMENTAL DATA - Temperature min. : C - Temperature max. : C - Altitude (m.a.s.l) : m - Plant location (geographic area, seismic zone,
More informationEnvironmental Clearance Maliparbat Bauxite Mines-Compliance Report Page 2
A. Specific Conditions: (i) All the conditions stipulated by the State Pollution Control Board in their consent to establish should be effectively implemented. Submission: Implementation is ongoing. (ii)
More informationMahabal Enviro Engineers Pvt. Ltd. At Booty, Near PHED Colony, Behind Pump House, PO - RMCC, District - Ranchi
Eco 'Ventures Pvt. Ltd Regd. Office: 2/37, Sarvapriya Vihar, Near IIT Gate, New Delhi-110016 Corporate Office: 7/8 Bhaveshwar Bhuvan, Opp Porthugese Church, Near Dindayal Upadhyay Garden, Gokhale Road
More informationKASIA IRON AND DOLOMITE MINE SIX MONTHS REPORT (OCTOBER, 2011 MARCH, 2012)
MONITORING OF BASELINE ENVIRONMENTAL PARAMETERS KASIA IRON AND DOLOMITE MINE Area of the mine: 194.196 Ha Kasia Village, Barbil Tehsil, Champua Sub Division, Keonjhar District, Odisha Of SIX MONTHS REPORT
More informationSchedule. Type of Test/ Properties Measured/ Range of Measurement. Biochemical Oxygen Demand (BOD) Calcium as Ca. Chromium, Hexavalent
LABORATORY LOCATION: (PERMANENT LABORATORY) Page: 1 of 12 SPECTRUM LABORATORIES (PENANG) SDN. BHD. 1904 TINGKAT 1, JALAN BUKIT MINYAK TAMAN SRI MANGGA, 14000 BUKIT MERTAJAM SEBERANG PRAI TENGAH PULAU PINANG
More informationHaryana Test House & Consultancy Services, 50-C, Sector-25, Part-II, HUDA, Panipat, Haryana. Discipline Chemical Testing Issue Date
Last Amended on 15.09.2014 Page 1 of 12 I. AIR, GASES & ATMOSPHERE 1. Ambient Air Particulate Matter (PM 10 ) IS: 5182 (Part-23) : 2006 (RA2012) 10 to 200 g/m 3 Particulate Matter (PM 2.5 ) Carbon Monoxide
More informationDetroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 6/9/2015
Lake Huron Plant Turbidity NTU 0.35 0.05 0.3/95% (1) Total Solids mg/l 136 162 500 10 Total Dissolved Solids mg/l 145 136 500 10 Aluminum Al mg/l 0.510 0.142 0.05-0.2 0.005 Iron Fe mg/l 0.082 0.118 0.3
More informationDeep Testing Laboratories, Plot No.- 338, Sector-58, Ballabhgarh, Faridabad, Haryana. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 6 I. METALS & ALLOYS 1. Plain Carbon & Low Alloy Steels Carbon IS 228 (Part-1) 1987, RA 2007 0.05% to 2.5% Mn IS 228 (Part-2) 1987, RA 2002 0.1% to 2.5% Si IS 228 (Part-8) 1989,
More informationJ. K. Cement Works, Nimbahra, District - Chittorgarh RAJASTHAN.
BASE LINE ENVIRONMENTAL MONITORING REPORT For J. K. Cement Works, Nimbahra, District - Chittorgarh RAJASTHAN. Season: Winter (1 st December -2016 to 28 th February -2017) Sponsor M/s. Enkay Enviro Services
More informationDurban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July June 2014
Durban Height Waterworks, Design capacity: 615 ML/d, Period: 01 July 2013-30 June 2014 Durban Heights WW Raw Durban Heights WW Final Determinands Units Minimum Average Percentile Maximum Minimum Average
More informationLake Huron Water Treatment Plant Mineral Report
Lake Huron Water Treatment Plant Mineral Report Turbidity NTU 0.40 0.05 0.3/95% (1) Total Solids mg/l 160 155 500 10 Total Dissolved Solids mg/l 101 0 500 10 Aluminum Al mg/l < 0.050 0.060 0.05-0.2 0.005
More informationDetroit Water and Sewerage Department Water Quality Division Laboratory Analysis of Water Samples Collected at Lake Huron Plant 10/14/2014
Lake Huron Plant Turbidity NTU 0.43 0.04 0.3/95% (1) Total Solids mg/l 103 116 500 10 Total Dissolved Solids mg/l 112 142 500 10 Aluminum Al mg/l < 0.050 < 0.050 0.05-0.2 0.005 Iron Fe mg/l 0.053 < 0.050
More informationLake Huron Water Treatment Plant Mineral Report
Lake Huron Water Treatment Plant Mineral Report Turbidity NTU 0.30 0.06 0.3/95% (1) Total Solids mg/l 94 91 500 10 Total Dissolved Solids mg/l 81 51 500 10 Aluminum Al mg/l < 0.050 < 0.050 0.05-0.2 0.005
More informationConcentration of Metals (Cd, Hg, Ag; mean +SD) in sediment samples collected from Pit Specific Sediment Chemistry Monitoring for CMP 1 in May 2014.
Figure 1: Concentration of Metals (Cr, Cu, Ni, Pb, Zn, As; mean +SD) in sediment samples collected from Pit Specific Sediment Chemistry Monitoring for CMP 1 in May 2014. Figure 2: Concentration of Metals
More informationhaving examined Legislative Decree No.21 of 1996 with respect to the and Ministerial Order No.10 of 1999 with respect to the Environmental
MINISTERIAL ORDER NO.3 OF 2001 WITH RESPECT TO AMENDING CERTAIN SCHEDULES ATTACHED TO MINISTERIAL ORDER NO.10 OF 1999 WITH RESPECT TO ENVIRONMENTAL STANDARDS (AIR AND WATER) AS AMENDED BY MINISTERIAL ORDER
More informationThe proposed Baddegedara reservoir project could be justified due to following reasons
CHAPTER 6 6.0 CONCLUSIONS The proposed Baddegedara reservoir project could be justified due to following reasons Salinity survey of existing wells pointed out high salinity in the coastal area of the project.
More informationWe are sending herewith the following for the month of September 2016.
ZZJ/CLAB-KSPCB/04/6499 07-10-2016 Environmental Officer, Regional Office, Karnataka State Pollution Control Board, Parisara Bhavan, LIG II, B 217, B-1, Main Road, A-16th Cross, Near Hari Om Trust, Habbuwada,
More informationZZK/CLAB-KSPCB/04/ Environmental Officer,
ZZK/CLAB-KSPCB/04/ 5491 09-10-2017 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwadaa
More informationZZL/CLAB-KSPCB/17/ Environmental Officer,
ZZL/CLAB-KSPCB/17/ 3657 10-10-2018 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada
More informationAppendix U. Mapping of Water Quality Concentration Contours across the Province
ALDERON IRON ORE CORP. ENVIRONMENTAL IMPACT STATEMENT KAMI IRON ORE MINE AND RAIL INFRASTRUCTURE, LABRADOR Appendix U Mapping of Water Quality Concentration Contours across the Province Figure 17I.1 Alkalinity
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name Kerry County Council Trading As INAB Reg No 340T Contact Name David Lenihan Address Laboratory, Arás Chontae, Rathass, Tralee, Kerry Contact Phone No 066 718
More informationZZM/CLAB-KSPCB/17/ Environmental Officer,
ZZM/CLAB-KSPCB/17/ 399 08-02-2019 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada
More information3. Up stream & Downstream water quality monitoring report of Kali River. ZZM/CLAB-KSPCB/17/ Environmental Officer,
ZZM/CLAB-KSPCB/17/ 724 12-03-2019 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada
More informationCERTIFICATE OF ANALYSIS
Your C.O.C. #: 32531001 Attention: Scott Churko Engineering and Operations Dpt PO Box 1390 Parksville, BC Canada V9P 2H3 CERTIFICATE OF ANALYSIS MAXXAM JOB #: B279455 Received: 2012/09/06, 09:15 Sample
More informationZZH/CLAB-KSPCB/04/ Environmental Officer,
ZZH/CLAB-KSPCB/04/ 21273 08-12-2014 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16 th Cross Near Hari Om Trust, Habbuwada
More informationZZL/CLAB-KSPCB/17/ Environmental Officer,
ZZL/CLAB-KSPCB/17/ 160 08-01-2018 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwadaa
More informationENVIRONMENTAL QUALITY STANDARDS REGULATIONS, 1999.
NATIONAL ENVIRONMENT MANAGEMENT ACT, 1994. ENVIRONMENTAL QUALITY STANDARDS REGULATIONS, 1999. IN EXERCISE of the powers conferred on the Council by sections 28(2) and 63(1) of the National Environment
More informationREVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS)
REVISED NATIONAL ENVIRONMENTAL QUALITY STANDARDS (NEQS) Background PEPC in its first meeting held on 10 th May 1993 approved the NEQS. The approved NEQS were uniform standards applicable to all kind of
More informationENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA
ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA Managed by Ministry of Science, Technology And The Environment Malaysia Concept of the National Policy Of The Environment 1 MALAYSIA POLICY ON THE ENVIRONMENT
More informationIndian Standard DRINKING WATER SPECIFICATION (Second Revision)
APPENDIX I BIS (IS 10500: 2012) Indian Standard DRINKING WATER SPECIFICATION (Second Revision) Sl No. Characteristic Requirement (Acceptable Limit) Permissible Limit in the Absence of Alternate Source
More informationENVIRONMENT MANAGEMENT PLAN
EMP 1 INTRODUCTION In each of the areas of impact, measures have to be taken to reduce potentially significant adverse impacts and where these are beneficial in nature, such impacts are to be enhanced/
More informationChapter 1 (BFC32403) and Standards
Chapter 1 (BFC32403) Environmental Rules, Regulations and Standards 1 ENVIRONMENTAL LEGISLATION AND REGULATION IN MALAYSIA Managed by DOE Concept of the National Policy Of The Environment 2 DEPARTMENT
More informationSPECIFICATION NO.1197S Addendum No.4 Attachment D. Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan
SPECIFICATION NO.1197S Addendum No.4 Attachment D Appendix L- Ground Water Quality Data and Revised Construction Groundwater Discharge Plan Page 1 of 2 Specification No. 1197S Addendum No. 4 ATTACHMENT
More informationAppendix C: Water Quality Data
Appendix C: Water Quality Data Your Project #: 111257005 Site: TIM HORTONS SYLVIA LAKE NSD # 16300R Attention: DAVID WHETTER STANTEC CONSULTING LTD 603-386 BROADWAY AVENUE WINNIPEG, MB CANADA R3C
More informationENVIRONMENTAL STANDARDS
ENVIRONMENTAL STANDARDS STANDARDS APPLICABLE TO THE COAL MINES 1) Air Quality (i) Work zone Standards for Coal Mines issued by MoEF, GSR-742 E dt. 25.09.2000 (ii) Residential category National Ambient
More informationBMM Ispat Ltd., Danapura Village, Hospet Taluk, Bellary District, PIN , Karnataka. ENVIRONMENT MONITORING REPORT. Stage I units. For.
BMM Ispat Ltd., Danapura Village, Hospet Taluk, Bellary District, PIN 583222, Karnataka. ENVIRONMENT MONITORING REPORT Stage I units For Nov 2015 Prepared by: M/s. Premier Analytical Laboratories, Near
More informationAnnex 2: National Environmental Quality Standards (Extract from the Gazette of Pakistan applicable to STZ CETP)
Annex 2: National Environmental Quality Standards (Extract from the Gazette of Pakistan applicable to STZ CETP) 1290 THE GAZETTE OF PAKISTAN, EXTRA, AUGUST 10, 2000 [PART-II] (1) For Annex, I the following
More informationPeriod: to
Half Yearly Compliance Report on Environmental Surveillance Monitoring & Compliance Status with respect to condition of Environmental Clearance vide letter No. J-11011/97/2004-IA.II (I) dated 2 nd December,
More information2. GUIDELINES FOR THE EVALUATION OF DRINKING-WATER QUALITY FOR HUMAN CONSUMPTION WITH REGARD TO CHEMICAL, PHYSICAL AND BACTERIOLOGICAL QUALITY
THE WATER ACT, 1956 (ACT 54 OF 1956 ) AND ITS REQUIREMENTS IN TERMS OF WATER SUPPLIES FOR DRINKING WATER AND FOR WASTE WATER TREATMENT AND DISCHARGE INTO THE ENVIRONMENT 1. INTRODUCTION The provisions
More informationWarm Mineral Springs Sampling by Sarasota County
Warm Mineral Springs Sampling by Sarasota County John Ryan, Kathryn Meaux, Rene Janneman and Jon S. Perry Sarasota County Environmental Services Sarasota, Florida September 11 Warm Mineral Springs is a
More informationZZJ/CLAB-KSPCB/04/ Environmental Officer,
ZZJ/CLAB-KSPCB/04/ 07-07-2016 4133 Environmental Officer, Regional Office, Karnataka State Pollution Control Board Parisara Bhavan, LIG II, B 217 B-1, Main Road, A-16th Cross Near Hari Om Trust, Habbuwada
More informationENVIRONMENTAL CLEARANCE (J-11015/121/ IA.II(M) ) October 14 to March 15. INTEGRATED ASHOK WASHERY cum FBC
ENVIRONMENTAL CLEARANCE (J-11015/121/2009 - IA.II(M) ) October 14 to March 15 INTEGRATED ASHOK WASHERY cum FBC (PIPARWAR AREA) CENTRAL COALFIELDS LIMITED Status of compliance of the terms and conditions
More informationFrench Creek Well # 2 Water Analysis Behind 1221 Ormonde Road
French Creek Well # 2 Water Analysis Behind 1221 Ormonde Road October 27 2010 Inorganics Fluoride 1.5 MAC 0.17 0.13
More informationAppendix F Project Environmental Standards
Appendix F TABLE OF CONTENTS 1 INTRODUCTION... 1-1 1.2 References... 1-1 1.3 Abbreviations and Definitions... 1-2 2 PROJECT AMBIENT AIR QUALITY STANDARDS... 2-3 3 PROJECT AMBIENT NOISE STANDARDS... 3-4
More informationWater Quality Concerns at Mines for Environmental Impact Assessment
Water Quality Concerns at Mines for Environmental Impact Assessment Bhargava K. Iyengar Assistant Professor, Dept. of Mining Engineering, MATS University, Raipur, Chhattisgarh, India ABSTRACT: The usefulness
More informationSchedule. This laboratory has demonstrated its technical competence to operate in accordance with MS ISO/IEC 17025:2005 (ISO/IEC 17025:2005).
LABORATORY LOCATION: (PERMANENT LABORATORY) EUROFINS NM LABORATORY SDN. BHD. NO. 27, JALAN IMPIAN EMAS 5 TAMAN IMPIAN EMAS 81300 SKUDAI, JOHOR MALAYSIA Page: 1 of 6 FIELD OF TESTING: CHEMICAL This laboratory
More informationCE 370. Wastewater Characteristics. Quality. Wastewater Quality. The degree of treatment depends on: Impurities come from:
CE 37 Wastewater Characteristics Quality Wastewater Quality The degree of treatment depends on: Influent characteristics Effluent characteristics Impurities come from: Domestic activities Industrial activities
More informationSchedule of Accreditation
Schedule of Accreditation Organisation Name Sourn Scientific Services INAB Reg No 194T Contact Name Catriona Donovan Address Unit 4, 4Park Business Centre, Farranfore, Kerry Contact Phone No 0669763588
More informationM/s: S.B Minerals Enterprises. Situated at Village - Pandru, Tehsil- Asind, District Bhilwara. RAJASTHAN.
ENVIRONMENTAL DATA GENERATION REPORT For M/s: S.B Minerals Enterprises. Situated at Village - Pandru, Tehsil- Asind, District Bhilwara. RAJASTHAN. Season: Winter (1 st October 2016 to 31 st December -2016)
More informationCERTIFICATE OF ANALYSIS REVISED REPORT
Your C.O.C. #: XXXXXXXX Attention: 23 MAIN ST, CITY, PROVIE COUNTRY POSTAL CODE Report Date: 5/09/7 Report #: XXXXXXXX Version: 2 - Revision MAXXAM JOB #: XXXXXXX Received: 5/09/03, 5:9 Sample Matrix:
More informationTable B1: Analytical Results for Nutrients in Surface Water
Table B1: Analytical Results for Nutrients in Surface Water Sample ID 1 2 Physical Tests Colour, True (Colour Units) 15 (4) units absolute, or 5 units above background (30-day average)
More informationAppendix B: Proposed trigger levels for groundwater quality and Response to Breach of Trigger Levels
Appendix B: Proposed trigger levels for groundwater quality and Response to Breach of Trigger Levels Trigger levels Miners Road and Selwyn McLeans Island Suite 1 - All wells ph field measurement
More informationQuestionnaire (Conventional Energy)
Questionnaire (Conventional Energy) QUESTIONNAIRE FOR CONVENTIONAL ENERGY (SECTOR-RELATED QUESTIONS) The completion of this questionnaire is voluntary. However, replying to the relevant questions as completely
More informationMagino Project Environmental Impact Statement. Technical Support Document Environmental Monitoring Plan
Magino Project Environmental Impact Statement Technical Support Document 20-13 Rev. No. Revision Date Approved 0 Document issued for EIS Table of Contents SECTION 1.0 Purpose of the Plan... 1 1.1 Scope
More informationAbu Dhabi Trade Effluent Standards & Regulations Summary
Abu Dhabi Trade Effluent Standards & Regulations Summary August 2010 Disclaimer: The standards & regulations provided here are attributable to the named source and are assumed to be accurate at the time
More informationAtmy Analytical Labs Pvt. Ltd., I-38, DLF Industrial Area, Phase-1, Faridabad, Haryana. Discipline Chemical Testing Issue Date
Last Amended on - Page 1 of 11 I. METAL & ALLOYS 1. Steel (Carbon Steel & Low Alloy Steel) Carbon ASTM E-415: 2014, IS 228 (Part 1): 1997 (RA 2008) 0.01 % to 1.5 % 0.01 % to 1.5 % Silicon ASTM E-415: 2014,
More informationVillage of McBride Annual Water System Report
Village of McBride Annual Water System Report - 2016 June 2017 The Village of McBride Annual Water System Report - 2016 McBride Water System Annual Report for 2016 In 2016 the McBride water system supplied
More informationA. Water sampling and analysis
A. Water sampling and analysis Parameter monitored Standard methodology used Detection limit Is this company accredited for this test? 1 ph Potentiometer 0.01 ph units No Temperature Electrometer probe
More informationBASE LINE ENVIRONMENTAL MONITORING REPORT
BASE LINE ENVIRONMENTAL MONITORING REPORT For M/s: Subhas Chand Mukesh Chand for an area of 123.66 Hectare. M.L No.-03/ 93A Village Bonda Gav, Tehsil - Weir, District Bharatpur, RAJASTHAN. Season: Summer
More information2019 Microbac Laboratories Inc. Ohio Valley Division
STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF WATER RESOURCES LABORATORY CERTIFICATION BRANCH In accordance with the provisions of N.C.G.S. 143-215.3 (a) (1), 143-215.3 (a)(10)
More informationEnvironmental Protection Licence 2688
Perilya Environmental Protection Licence 2688 Licensee Perilya Broken Hill Limited (PBHL) Address Wentworth Rd, Broken Hill, NSW, 2880. Environmental Protection Licence 2688 (Southern Operations) Link
More informationMount Polley Mining Corporation an Imperial Metals company Box 12 Likely, BC V0L 1N0 T F
Mount Polley Mining Corporation an Imperial Metals company Box 12 Likely, BC V0L 1N0 T 250.790.2215 F 250.790.2613 November 24, 2016 Ministry of Environment Mining Operations Environmental Protection 2080
More informationKits. Item Product name Article Number 1 ACIDITY TEST AQUAMERCK ALCOHOL TEST MG/L REFLECTOQUANT
Kits Item Product name Article Number 1 ACIDITY TEST AQUAMERCK 1.11108.0001 2 ALCOHOL TEST 15-150 MG/L REFLECTOQUANT 1.17946.0001 3 ALKALINITY TEST AQUAMERCK 1.11109.0001 4 ALUMINIUM TEST 0.020-1.20 MG/L
More informationBHUSHAN STEEL LIMITED Environmental Assessment for 5.6 MTPA Steel Plant Expansion at Meramandali, Orissa
BHUSHAN STEEL LIMITED Environmental Assessment for 5.6 MTPA Steel Plant Expansion at Meramandali, Orissa CONTENTS Sl. No. 1. INTRODUCTION Description Page No. 1 1 to 1 7 2. PROJECT DESCRIPTION 2 1 to 2
More informationPeriod of Time Contaminant is Measured. 1 - hour average 8 - hour average 20 (17) Guideline Micrograms per cubic metre of air 1 - hour average 4.
Units of is Ammonia Milligrams per cubic metre (parts 1.4 (2.0) 7 Arsenic Micrograms per cubic metre of air 0.3 20 Cadmium Micrograms per cubic metre of air 2 20 Carbon Monoxide Objective Milligrams per
More information