K-FLEX K-FONIK INDUSTRIAL

Similar documents
K-FLEX K-FONIK INDUSTRIAL

L'ISOLANTE K-FLEX. LNG applications Manual

INDUSTRIAL SYSTEMS. Application Manual for Piping Equipment. ARMASOUND INDUSTRIAL SYSTEMS - Application Manual for Piping Equipment

O c t o b e r K-FLEX. Acoustic Insulation

SPECIFICATION GUIDELINES FOR THE USE OF CRYOGEL Z ON COLD PIPING AND EQUIPMENT

10.1 APPLICATION 1 A. HOT PIPING 1 B. ANTI SWEAT PIPING 1 C. COLD PIPING FINISHES 2

APPLICATION INSTRUCTIONS FOR MUFFL-JAC ACOUSTICAL JACKETING ON HOT PIPE INSULATION

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for CHILLED WATER SYSTEMS

Acoustic Insulation. p r o d u c t s f o r a c o u s t i c i n s u l a t i o n

ACOUSTICAL INSULATION (LAGGING) FOR PIPING AND EQUIPMENT

Pipe Supports Comparison

INSTALLATION GUIDELINES for ISO-C1 POLYISOCYANURATE MECHANICAL INSULATION for LIQUEFIED NATURAL GAS (LNG) CRYOGENIC REFRIGERATION CHILLED WATER

379 Quick Installation Guide

K-FLEX. Acoustic Insulation. solutions for acoustic comfort

079 Quick Installation Guide

Cold Work Cladding Fabrication & Application

KoolthermTM. Installation Guide. HVAC & Building Services Pipe Insulation

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

SECTION MECHANICAL INSULATION. A. Types of insulation specified in this section include the following:

KNOW-HOW. Quality characteristics of technical insulation materials: Fast and reliable installation is crucial

Recommended Installation and Repair Guide

ITW INSULATION SYSTEMS

GUIDE SPECIFICATION: MECHANICAL SYSTEMS

a d v a n c e d e l a s t o m e r i c t h e r m a l a n d a c o u s t i c i n s u l a t i o n m a t e r i a l s

ITW INSULATION SYSTEMS

Edition Edition 2018 K-FLEX K-FLEX AL CLAD. Application manual

SECTION HVAC INSULATION

AIC Tech Energy Efficiency - Road Map to a Sustainable Future

PIP INSA1000 Acoustic Insulation Systems Specification

1. Division 23 Section "Hangers and Supports for HVAC Piping and Equipment" for pipe insulation shields and protection saddles.

FIRE STATION 55 June 14, 2010

Division 15 INSULATION Section 15100

Pipe and Equipment Insulations. Zeston. PVC Insulated Fitting Covers Installation Instructions for Hot, Cold and USDA Piping Systems

Sheet Insulation - Rectangular ducts. Installation Manual

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section PIPE AND EQUIPMENT INSULATION

1 of 17. PO Box Bellevue Rd, Newark, DE V F

Sheet Metal Protective Films

SECTION (15081) - HVAC INSULATION

Elastomeric Rubber Foam Sheets/Rolls. Thickness

ITW INSULATION SYSTEMS

PIPE AND EQUIPMENT INSULATION

INSTALLATION GUIDELINE FOR TRYMER INSULATION

ULVAShield non-metallic cladding installation procedures rev7

Installation Manual PIPE AND EQUIPMENT INSULATION

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

Solutions for industrial pipe work insulation

CERTIFICATE OF APPROVAL No CF 5073 LEMINAR AIR CONDITIONING INDUSTRIES L.L.C.

PLYWOOD FLOATING FLOOR

This specification describes the minimum requirements for industrial thermal insulation.

FireX Fire Stopping Mastic FM

Installation Manual PIPE INSULATION FOR COLD SERVICE

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

1. The subfloor must be structurally sound and able to withstand live and dead loads with a deflection limitation of L/360.

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

Recommended Installation & Maintenance Guidelines

A. Section Fire Procection, HVAC & Plumbing Penetration Firestopping. B. Section Interior Painting: Painting insulation jacket.

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

SECTION HVAC PIPING INSULATION

SRP-AirOutshield UV Issued:

SECTION PIPING INSULATION

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

Mechanical Insulation for Refrigeration Systems

K-FLEX SOLAR SYSTEM SOLAR SYSTEM

Addendum to Specifications

Design & Construction Standards, Revised January

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

PIPE INSULATION THERMAL & ACOUSTIC PIPE LAGGING. allproof.com. Page 1

INSTALLATION GUIDELINE FOR TRYMER INSULATION ITW INSULATION SYSTEMS

1.2 The Engineer shall select appropriate sections of the specification to ensure that the specification is comprehensive for specified work.

Marine & Offshore Fire Divisions. bulkhead, deck & floor systems

Duct Wrap Flexible Wraps

Addendum 1 Section THERMAL INSULATION FOR PIPING Burrow Avenue Pumping Station Upgrades Page 1 of 5

FLEXIBLE MECHANICAL PROTECTION

TENOCHCA HALL - PROJECT NO FAN COIL UNITS, RESTROOM AND FINISH RENOVATION

PROJ. NO SECTION HVAC DUCT INSULATION

CRYOGENIC SUPPORTS INTRODUCTION

CRYOGENIC SUPPORTS INTRODUCTION

Project Specification. Tarec. Insulation for the LNG, Petrochemical and Process Industries

Light-Metal Roof Edge, Raised

INSTALLATION GUIDE GUIDE TO ASC ISO-WALL CONSTRUCTION SYSTEM APPLICATION ISO-WALL SYSTEM. ASC Iso-Wall System Includes: Materials Required:

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

SUPERIOR CAL-SHIELDS Features & Benefits FAST

Isolation vs Insulation:

SECTION IDENTIFICATION FOR PLUMBING PIPING AND EQUIPMENT

A. Deliver material to job site in original, nonbroken, factory packaging, labeled with manufacturer's density and thickness.

Industrial Systems THE FIRST SOUND CONTROL SYSTEMS TO MINIMISE THE RISK OF UNDER INSULATION CORROSION. Industrial Systems

GUIDE SPECIFICATION: DUCT LINER

FireMaster Marine Plus Profile Wrap Systems for Composite Bulkheads and Decks

NCCER Progress Blvd, Alachua, Florida Tel: (888)

UBC Technical Guidelines Section Edition Thermal Insulation for Piping Page 1 of 5

INSTALLATION GUIDELINES FOR CHILL WATER PIPE INSULATION

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

Revision:C Pipework Insulation Issued:14/11/2012 PIPEWORK INSULATION CU14. 14/11/2012 Page 1 of 10 Pipework Insulation - RevC

PIPEWORK INSULATION. 14/ Page 1 of 10 Pipework Insulation Rev D

Division 07 Thermal and Moisture Protection Thermal Protection Blanket Insulation Page 1 of 17

Transcription:

J a n u a r y 2 0 1 3 K-FLEX K-FONIK INDUSTRIAL Sound & Thermal Insulation design compliant with ISO 15665 www.kflexenergy.com

Flexible Elastomeric Foam layer INSULATING PIPING WITH K-FLEX SHEETS > FIRST LAYER Wrap a strip of K-FLEX of the same thickness as that to be used around the pipe to be insulated and measure the exact length required. Wrap the insulation sheet around the pipe and press the glued edges together starting at the ends, then the center and then working along the rest of the length. Glue the insulating sheeting to the subsequent sections along the length of the pipe. > OTHER LAYERS LONGITUDINAL CROSS-SECTION CROSS-SECTION Measure the overall diameter with the first sheet in place. Wrap the insulation sheet around the tubing, ensuring that the seam does not overlap that of the underlying insulation. Adjacent sections of insulation should be glued at their respective ends. When installing the second layer, make sure that the seams do not overlap those underneath (see diagram). This ensures that, when the plant is operational, maximum insulating properties are maintained as the materials expand or contract. Seams staggered NB: > Recommended glue: K-FLEX K-414 or K-FLEX K-420, over 100 C use K-FLEX K-425 HT for high temperature > No Overlap > Adjacent sections of insulation should be glued at their respective ends. > Thoroughly degrease the surface to be insulated with the producer s specified thinners 5

Flexible Elastomeric Foam layer ELBOWs and T pieces SPECIAL PARTS For all layers of insulation, the FITTINGS (VALVES, FLANGES etc) must be sized, shaped and assembled, glued together, as indicated in the installation manual. Application guide ENG REFERENCE (pipes, elbows, T Fittings, Valves, Flanges) should always be installed according to the K-Flex Application Manual more information at www.kflex.com 6

K-FLEX K-FONIK OPEN CELL 240 AbsoRPTION and DISSIPatION LAYER installation: K-FLEX K-FONIK OPEN CELL 240 When installing K-FLEX K-FONIK OPEN CELL 240 please use the same process as for closed cell sheets. The instructions in the K-FLEX INSTALLATION MANUAL should therefore be referred to for each stage of the installation, including sizing, cutting and gluing of both the straight sections and any special items such as elbows, fittings, valves, flanges, etc. NB: > Recommended glue: K-FLEX K-414 or K-FLEX K-420, over 100 C use K-FLEX K-425 HT for high temperature > No Overlap > Adjacent sections of insulation should be glued at their respective ends. Seams staggered OPEN CELL 240 REFERENCE K-FLEX OPEN CELL 240 (pipes, elbows, T Fittings, Valves, Flanges) should always be installed according to the K-Flex Application Manual more information at www.kflex.com Application guide E N G OPEN CELL 240 7

K-FLEX K-FONIK GK or GV (mass barrier) MASS BARRIER K-FLEX K-FONIK GK K-FLEX K-FONIK GV HIGH-DENSITY ELASTOMERIC ACOUSTIC INSULATING PANEL, AVAILABLE PRE-CUT TO SIZE FOR OEM AND INDUSTRIAL APPLICATIONS. K-FLEX K-FONIK GK is a viscoelastic acoustic insulation product made with partially reticulated polymers. Its special sound insulation characteristics make this an excellent product for traditional applications in the construction sector, eg. acoustic insulation of brick walls and plasterboards and for O. E. M. application. K-FLEX K-FONIK GV is a viscoelastic acoustic insulation product made with partially reticulated polymers and fire-proof mineral fillers. Its special sound insulation characteristics make this product an excellent solution for the shipbuilding and railway sectors. NB: To install the acoustic material where required, please use the correct procedure as follows: 1.The acoustic barrier shall be secured tightly around the whole of the insulated equipment using stainless steel bands, 20 mm wide x 0.50 mm thick secured with a suitable buckle type fixing. Each one metre length of installation requires a minimum of 3 steel bands. 2.All fabricated items shall, where applicable, have a minimum 50 mm overlap on all seams and joints. Before securing the stainless steel bands, it is important to apply K-FLEX K-420 or KFLEX K-414 adhesive with a brush onto both surfaces of the overlap area. OPEN CELL 240 GK GK 8

K-FLEX IN CLAD Jacketing Flexible polymeric covering of 1 mm in thickness. K-FLEX IN CLAD gives long lasting protection against aggressive marine environments and is UV and vapour resistant. 1 1. PreparaTION OF IN CLAD Jacketing > From a roll of K-FLEX IN CLAD, cut a sheet with the same width as the circumference of the insulated tube, adding an excess of roughly 50 mm for the longitudinal overlap. 2. Installation > Apply a layer of K-FLEX K-420 glue along the section of the tube to be covered with K-FLEX IN CLAD. > Position the K-FLEX IN CLAD on the area where the glue has been applied and from that point wrap the K-FLEX IN CLAD sheet around the whole section. > Securely press down the K-FLEX IN CLAD covering along the whole circumference, in order to obtain a tightly fitting cover. > With a brush, apply K-FLEX K-420 adhesive on both ends in order to obtain a perfect seal against water between the covering and the insulation material. NB: Take care to stagger the edges of the insulation and the the edges of K-FLEX IN CLAD to avoid continuity with the underlying. Each sheet of K-FLEX IN CLAD should be positioned in such a way as to overlap the next sheet by at least 50 mm. Use K-FLEX K-420 on both the longitudinal and transverse overlaps. 3. applying marine sealant > Apply a 10 mm width and 4 mm thick layer of marine sealant K-FLEX K-Mastic 55 on both sides of all the joints. edge. OPENCELL 240 GK IN CLAD REFERENCES! Installation Manual K-FLEX IN CLAD SYSTEM IN CLAD Jacketing should always be installed according to the K-Flex IN CLAD Application Manual or K-FLEX IN CLAD Jacketing Application Manual more information at www.kflex.com 9

PIPE SUPPORTS and acoustic/thermal bridges PIPE SUPPORTS AND STEEL INSTALLATIONS 1. Where there are space restrictions and it is not possible to fully insulate pipe supports and steel installations to the correct specified thickness, the insulation layer must be trimmed closely around the steel support leaving no gaps. 2. All cut-away areas must be sealed with the appropriate K-Flex adhesive AND K-mastic to protect them from the environment and maintain maximum insulation. 3. All steel work connected directly to the main installation must be insulated to the same thickness and combination of insulation materials so as to avoid acoustic bridging and maintain optimum performance. 10