Biomolecular Interaction Analytics using MicroScale Thermophoresis

Similar documents
MST Starting Guide Monolith NT.115

Microscale Thermophoresis

Some like it hot: Biomolecule Analytics using Microscale Thermophoresis

nanodsf 2bind: Your service provider for biophysical characterization of proteins Precisely revealing protein folding and stability

Monolith NT.115 Series Product Information

Prometheus Series Product Information

Fluorescence Spectroscopy and Microscale Thermophoresis

Methods 59 (2013) Contents lists available at SciVerse ScienceDirect. Methods. journal homepage:

Prometheus NT.48 Product Information

Electronic Supplementary Information. Evolved polymerases facilitate selection of fully 2 - OMe- modified aptamers

SunScript TM One Step RT-qPCR Kit

PolarScreen Tyrosine Kinase Assay Kit, Far Red Protocol

SpectraMax Quant AccuBlue Pico dsdna Assay Kit

UV Fluorescence Polarization as a Means to Investigate Protein Conformational and Mass Change

QPCR-S100 (100 rxns) Store -20. Functional analysis RealHelix qpcr Kit was evaluated by real-time PCR using the 10-fold serial-diluted human

CBI Toolbox Tour 2015

Guidelines for Developing Robust and Reliable PCR Assays

+ M III. IMAP Screening Express Kit Product #8073 Quantity: 8000, 20 µl reactions (80 µl final volumes) Low FP. M III High FP.

Roche Molecular Biochemicals Technical Note No. LC 12/2000

MATERIAL DATA SHEET. Reagents Provided in Kit

Optimization of an Adapta Kinase Assay for Cdk9/cyclin T1

Human ICAM-2 / CD102 ELISA Pair Set

Biophysics of Macromolecules

Human IL10RB ELISA Pair Set ( CRFB4 )

Human PRLR / Prolactin Receptor ELISA Pair Set

Capillary Electrophoresis of Proteins

Roche Molecular Biochemicals Technical Note No. LC 10/2000

SpectraMax Quant AccuClear Nano

Human CD21 ELISA Pair Set

Masayoshi Honda, Jeehae Park, Robert A. Pugh, Taekjip Ha, and Maria Spies

MATERIAL DATA SHEET. Reagents Provided in Kit

FastFire qpcr PreMix (Probe)

Real Time Quantitative PCR Assay Validation, Optimization and Troubleshooting

Biophysical characterization of proteinprotein

Sulfhydryl Immobilization Kit for Proteins

BD Ratiometric Calcium Assay Kit

SUPPORTING INFORMATION. A cleavage-responsive stem-loop hairpin for assaying guide RNA activity

PRODUCT DATA SHEET. Carboxylated Fluorescent Gold Nanoparticles. Description. Characteristics

A Picofluor method for RNA quantitation using RiboGreen

NHS-Activated Agarose (Dry Form)

Ratiometric Calcium Assay Kit

QuantiFluor dsdna System

AnaTag HiLyte Fluor 750 Microscale Protein Labeling Kit

Human Junctional Adhesion Molecule A / JAM-A ELISA Pair Set

Tyrosine Kinase Assay Kit, Red*

TECHNICAL NOTE Phosphorylation Site Specific Aptamers for Cancer Biomarker Peptide Enrichment and Detection in Mass Spectrometry Based Proteomics

RealHelix TM qrt-pcr Kit [Intercalator type]

Thermo Scientific DyNAmo Probe qpcr Kit

ALP (alkaline phosphatase) calibrators were analyzed manually in microtiter plates to find the linearity range by following this protocol:

User Manual. NGS Library qpcr Quantification Kit (Illumina compatible)

MSD Immuno-Dot-Blot Assays. A division of Meso Scale Diagnostics, LLC.

Mouse IFNAR1 ELISA Pair Set

Discovery of an entropically-driven small molecule streptavidin binder from nucleic acid-encoded libraries


protein interaction analysis

TECHNICAL BULLETIN. In Vitro Bacterial Split Fluorescent Protein Fold n Glow Solubility Assay Kits

MagExtactor -His-tag-

Electrophoresis and the Agilent Bioanalyzer. Advanced Biotechnology Lab I Florida Atlantic University January 23, 2008

Universal Methyltransferase Activity Assay Kit

AnaTag HiLyte Fluor 647 Microscale Protein Labeling Kit

PolarScreen Estrogen Receptor-β Competitor Assay, Green. Table of Contents

mmu-mir-200a-3p Real-time RT-PCR Detection and U6 Calibration Kit User Manual MyBioSource.com Catalog # MBS826230

AnaTag HiLyte Fluor 488 Microscale Protein Labeling Kit

Improving the Limit of Detection of Lateral Flow Assays using 3DNA Technology

GE Biacore T Check that the waste bottle is empty.

Accurately and reproducibly quantify as little as 20 fg of human DNA using real-time PCR.

Bacteriophage MS2. genesig Standard Kit. Phage MS2 genome. 150 tests. Primerdesign Ltd. For general laboratory and research use only

Supplementary Information. Human Antibody-Based Chemically Induced Dimerizers for Cell Therapeutic Applications

Cat # BRD-Kit-01. For 320 reactions. Instruction Manual. For Research Purposes only

Assays for gene expression and protein production

For in vitro Veterinary Diagnostics only. Kylt Brachyspira spp. Real-Time PCR Detection.

SensoLyte 440 West Nile Virus Protease Assay Kit *Fluorimetric*

Towards Single Molecule Detection of SEB A Mobile Sandwich Immunoassay on Gliding Microtubules. Dr. Carissa M. Soto

Calcium Assay Kit. Technical Data Sheet. Product Information. Description. Storage. Materials not included

Human IGFBP7 ELISA Pair Set

For in vitro Veterinary Diagnostics only. Kylt Avian Nephritis Virus. Real-Time RT-PCR Detection.

Accurately and reproducibly quantify as little as 20 fg of human DNA using real-time PCR.

Polymerase Chain Reaction Quality Control and Quality Assurance

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

PRODUCT DATA SHEET. Carboxylated Gold Nanoparticles. Description. Features. Storage. Applications. Handling. Characteristics

SuperReal PreMix Plus (SYBR Green)

For in vitro Veterinary Diagnostics only. Kylt MHRS Triplex. Real-Time PCR Detection.

QS S Assist KINASE_MSA Kit

Epoxy Microarray Slides

Contact Details. Dr Alexander Galkin. Office: MBC Room 186. Tel: (028) Frequency and wavelength.

Best Quantification Practices with the Agilent 5200 Fragment Analyzer System

LanthaScreen TR-FRET Coregulator Protocol and Assay Conditions Revised 31-Jul-2017

HELINI Hepatitis B virus [HBV] Real-time PCR Kit (Genotype A to H)

SunScript One Step RT-PCR Kit

QS S Assist STK_FP Kit

Conflicts of Interest. Rapid Cycle PCR (20 60 second cycles) How long does it take to. 10/16/2014

Phosphate buffered saline (PBS) for washing the cells TE buffer (nuclease-free) ph 7.5 for resuspending the SingleShot RNA control template

For in vitro Veterinary Diagnostics only. Kylt Influenza A - H9. Real-Time RT-PCR Detection.

Human CALML5 ELISA Pair Set

High specificity and sensitivity for fungal DNA allows reliable quantification in a background of nonfungal. Contents

For in vitro Veterinary Diagnostics only. Kylt Chlamydiaceae Screening. Real-Time PCR Detection.

For in vitro Veterinary Diagnostics only. Kylt Avian Hepatitis E. Real-Time RT-PCR Detection.

Accurately and reproducibly quantify as little as 20 fg of bacterial DNA using real-time PCR.

For in vitro Veterinary Diagnostics only. Kylt E. coli F18, F41, Stx2e. Real-Time PCR Detection.

BIAffinity Application Note

Transcription:

Biomolecular Interaction Analytics using MicroScale Thermophoresis The Monolith NT.115 Dinorah Leyva, Ph.D. NanoTemper Technologies Inc. 395 Oyster Point Blvd. Suite 135, South San Francisco, CA www.nanotemper-technologies.com

Stefan Duhr Philipp Baaske 2008 2010: Monolith NT.115 Fast thermo-optical particle characterisation PCT Patent 2008/061706 2012: Monolith NT.LabelFree 2013: Monolith NT.115 Pico 2014: Monolith NT.Automated 2014: PROMETHEUS NT.48 1856: Carl Ludwig 1879: Charles Soret

Agenda Seminar MicroScale Thermophoresis (MST) Basics Assay Setup Assay Optimization Experimental work Measurement of positive control Sample handling and assay setup NT.Control and NT.Analysis Software Run experiments with your own samples

Thermophoresis in Real Time DNA Microbeads Positive thermophoresis Negative thermophoresis

Theory of Thermophoresis c hot / c cold = exp (-S T ΔT) Laser on Laser off Size Charge 2 Hydration shell + - Duhr and Braun PNAS 103, 19678 19682 (2006) Duhr and Braun PRL 96, 168301 (2006)

Interactions accessible with MST

Optical MicroScale Thermophoresis Basic setup of the instrument LED excitation & fluorescence detection dichroic mirror IR laser Immobilization-free in buffer or complex bioliquids objective 4 µl of sample per titration point nm concentrations of fluorescent molecule capillary 40 sec measurement per titration point

MicroScale Thermophoresis: Physical Processes Sample heating < 1 sec IR laser induced temperature field 23 C Thermophoresis ~ 30 sec 20 C 1K/10 µm corresponds to 1000K/cm Jerabek-Willemsen et al, ADDT, 2011

Phases of a MST Signal LED excitation & fluorescence detection dichroic mirror IR laser objective capillary Jerabek-Willemsen et al, ADDT, 2011

MST Binding Curve Ligand Fluorescent molecule F cold F hot Saturation K d F hot / F cold Baseline Ligand (nm)

Interaction of Fluorescently Labeled Hsp90 with 17-DMAG K d : 0.503 µm Results were kindly provided by Stephen McLaughlin, MRC-LMB, Cambridge, UK Interactions that do not alter the MW of a protein, only the conformation (hydration shell)

Nitrate binding to a 12 Transmembrane-Helices Transporter Parker & Newstead, Nature, 2014 Unmatched sensitivity of MST: small nitrate molecule binding to a large 12 Transmembrane-Helices Transporter

Competitive Approach for p38 using a fluorescent Tracer T Binding of p38 to Tracer T C1 T Competitive Assay w ith Compounds T C1 Competition experiments are essentially label-free and site-specific Material was kindly provided by Dr. Krishna Saxena, University Frankfurt, Germany

BLIP TEM1 Interaction studies

MST Application Notes and many more! www.nanotemper-technologies.com/applications

Selected MST Publications Nature: Molecular basis of nitrate uptake by the plant nitrate transporter NRT1.1. Parker and Newstead, Nature, 2014, 507, 68-72 RNA Biology: Microscale thermophoresis provides insights into mechanism and thermodynamics of ribozyme catalysis. Gaffarogullari E. C., et al. RNA Biology, 2013, 10, 1-7 Methods: "Microscale thermophoresis quantifies biomolecular interactions under previously challenging conditions." Seidel S. A., et al. Methods, 2013, 59, 301-315 Nature: "Receptor binding by a ferret-transmissible H5 avian influenza virus." Xiong X., et al. Nature, 2013, 497, 392-396 Cell: "Inhibition of basal FGF receptor signaling by dimeric Grb2." Lin C. C., et al. Cell, 2012, 149, 1514-1524 J Biol Chem: "Mechanisms of unphosphorylated STAT3 transcription factor binding to DNA." Timofeeva O. A., et al. J Biol Chem, 2012, 287, 14192-14200 and many more! www.nanotemper-technologies.com/publications/

Overview of Topics Assay Setup Sample labeling and important pre-tests Serial dilution and loading of capillaries NT.Analysis and NT.Control Software Assay optimization Aggregation Fluorescence changes Noise level

General Remarks on Sample Handling Concentration of fluorescent molecule: in the same range or lower than the expected K d Highest concentration of ligand: 20 fold above the expected K d Final sample volume per titration point: 20 µl Use small tubes for the serial dilution: e.g. PCR strips, tubes Dilution buffer should not vary in composition in serial dilution: e.g. DMSO Accurate pipetting is essential Mix with pipette instead of vortexing Do not touch capillaries in the center

The Fluorescent Molecule: Sample Preparation Monolith NT.115: Label one binding partner using a NT fluorescent dye Expression of a fusion protein (GFP, YFP ) Synthetic fluorescent samples (nucleic acids, peptides) Different methods: in vitro translation, incorporation of unnatural amino acids Protein labeling: NanoTemper Protein Labeling Kits are optimized for MST Use only high purity samples (>95%) Amine-reactive vs. cysteine-reactive labeling Efficient removal of free dye

The Fluorescent Molecule: Cap Scan Aim Check protein labeling efficiency Select proper capillary (Standard treated, Hydrophilic, Hydrophobic and Premium coated)

The Fluorescent Molecule: Cap Scan Fluorescence intensity: 200 1500 counts Fluorescence signal < 200 counts: Increase LED power Increase fluorophore concentration Optimize labeling efficiency Fluorescence signal > 1500 counts: Decrease LED power Dilute sample Check for presence of free dye

The Fluorescent Molecule: Cap Scan Split peaks or shoulders: Change capillary type (Standard or Premium coated) Optimize buffer

Capillary and Buffer Selection Load same sample in your assay buffer (4 capillaries each) and measure with 40 % MST power Noise level 6-8 units Test different types of capillaries Test/improve buffer conditions Capillary: std. premium std. premium By adding detergents such as Tween 20, Assay buffer MST optimized buffer Pluronic-F127, By changing ph or ionic strength

The Ligand: Concentration Finder Tool Note: This tool can be accessed via NT.Control Software or NanoTemper website

Serial Dilution Ligand Fluorescent Molecule 20 µl 200 µl stock 10 µl buffer Serial dilution Ligand dilution Fill capillary

Sample Loading

Software and Data Analysis - Overview Running MST Experiments: NT.Control Software Analyzing MST Data: NT.Analysis Software Adjust LED power to excite the fluorescent molecule Set MST power to induce the temperature gradient Fit curves to determine K d or EC 50 Export your data

Overview of Topics Assay Setup Sample labeling and important pre-tests Serial dilution and loading of capillaries NT.Analysis and NT.Control Software Assay optimization Aggregation Fluorescence changes Noise level

Labeling Strategy and Labeling Position 4 lysines are involved in binding

Labeling Strategy and Labeling Position Alternative labeling strategies Different coupling chemistry (maleimide labeling) Different dye K K K K K K K K K K K K K K Fusion protein (GFP, YFP, ) Protection of binding site Site-specific label (unnatural amino acids, in vitro translation...) Alternative assay strategies Competition experiment K K K K K K K K K K K K K K

Aggregation No aggregation Aggregation Buffer optimization is necessary: Detergents and additives (Tween-20, Pluronic F-127, BSA etc.) Centrifugation ph, ionic strength Concentration of organic solvents (DMSO)

Random Fluorescence Changes Random fluorescence changes Inaccurate pipetting Low sample quality Leads to increased noise level Buffer optimization necessary < ±10 % ±10 %

Ligand-induced Fluorescence Changes! Fluorescence quenching or enhancement induced by ligand binding Ligand-induced surface adsorption or Aggregation Perform SDS-denaturation (SD) test

Binding or Material Loss? How to perform the SD-Test Assay Optimization www.nanotemper.de

What is an acceptable Noise Level? Amplitude should be at least 3-fold above the noise level

Assay Optimization Summary Easy and straight forward assay optimization

Data Profiles T-Jump (+) and thermophoresis (+) T-Jump (+) and thermophoresis (+/-) T-Jump (+/-) and thermophoresis (+/-) T-Jump (+/-) and thermophoresis (+/-)

NanoTemper Technologies: Customer Support NanoTemper Technologies support: From Scientists for Scientists Individual support: Discuss your approach and your data Please feel free to contact us: Dinorah Leyva, Ph.D. NanoTemper Technologies Inc 395 Oyster Point Blvd, Suite 135 Experienced Application Scientists: Help with challenging samples MST User Trainings: Intensive courses using your own samples South San Francisco, CA 94080 www.nanotemper-technologies.com dinorah.leyva@nanotemper-technologies.com