Sageon Site Monitor (SSM) Application Note

Similar documents
MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

Calibrate Accessory Actuators Instructions

92831 TEL: (714) FAX:

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

UNI BAR. user manual. ELATION UNI BAR user manual

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Thermoelectric Cooler

Precision Automatic Vacuum Control (PAVC+)

Maintenance Bypass Breaker Cabinet Series Configuration 2. Installation and Operation Manual

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

OPTO BRANCH 8. ELATION OPTO BRANCH 8 user manual 1.0

DMX-BRANCH/4. user manual. ELATION DMX-BRANCH/4 user manual

FTW 175 Wireless Monitoring System Reference Manual Part Number

Installation and Operation Manual

Maintenance Bypass Breaker Cabinet Series Configuration 5. Installation and Operation Manual

TL-600 MOBILE PHASE HEATER

78-RK VARIABLE SPEED HEAVY DUTY VIBRATOR OPERATING MANUAL

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

INSTRUCTION MANUAL PHANTOM LOAD MODEL PA For SERIAL NO.

Quick Start Guide. Effective February 2015 New Information

TR1 TR2. Transformer / Relay Adapter. Installation Manual. Rev 1.1 Feb. 22, Deklin Technologies Inc 413 Childe Harolds Lane Brentwood, TN 37027

CFL Series User Manual

Effective This guide supersedes all previous versions

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

92831 TEL: (714) FAX:

MANUAL. ENGLISH Antenna Booster Ordercode: D1425. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Canon U.S.A. Inc. Business Policies and Procedures Manual Section No: BPP400 (Logistics)

Dynatronics Parallel Bars

Car and Counterweight Frames

Installation, Operation & Maintenance Manual

Product Warranty Program

USER'S GUIDE TO OPERATION

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

Beach House Cargo Lifts Branded Product of Cargo Lift Distributors

CTL3000. Instruction Manual Full Extractive Probe Controller Assembly Part Number May2008

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

4-Wire Buffer Amplifier. User Manual

PAGODA SERIES OPERATOR'S MANUAL

Limited Product Warranty

City of San Mateo Clean Water Program Programmable Logic Controller (PLC) and Human Machine Interface (HMI) Programming Services

SERVICE REMOTE CONTROL For Use with Geberit Electronic Flush Valves and Faucets

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

XBLUE NETWORKS WARRANTY AND CUSTOMER SERVICE POLICY AND PROCEDURES

ENGLISH WiFi Module for GIG-202 Tab

REVISION NO.: 8 EFFECTIVE: 03/26/18

WARRANTY AND SERVICE POLICY

Introduction TMD Warnings and Cautions Caution: Caution: Caution: Caution: Caution: Caution: Modification

RJE INTERNATIONAL, INC. U LB-364EL R EV 3.2

Change-over and monitoring unit For medical locations acc. to DIN VDE 0100 Part 710

ALTRONIC RESEARCH, INC.

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

File In/With: Equipment Affected:

RJE INTERNATIONAL, INC.

Quick Start Guide WaveMaster

WARNING ELECTRIC PALLET TRUCK EPT Revised A company dedicated to solving ergonomic and material handling problems since 1955.

NOVALYNX CORPORATION MODEL B & M-B EVAPORATION GAUGE TESTER INSTRUCTION MANUAL

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

MANUAL ENGLISH. Ordercode: D3423/D3423W. Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

Credit Application. JMF Company and Subsidiaries nd St. Ct. Fax: (563)

OEM Policy. Information for Original Equipment Manufacturers

Model 292A. Surface Resistance Test Kit. Instruction Manual

HDI 2200 Choke Position Indicator

AIRSTREAM DMX BRIDGE. User Instructions

User s Manual. June 23, 2017 P/N Revision D. TURNER DESIGNS 1995 N. 1 st Street San Jose, CA Phone: (408) FAX: (408)

Sby SR Instruments, Inc.

Pad and Pad/Transformer Modules

Aftermarket Parts. Open account terms must be strictly adhered to. Payment is expected within 30 days of merchandise delivery.

CUSTOMER S OWN MATERIALS (COM)

DRS220. DRS220 Digital Refrigerant Scale Limited Warranty. Digital Refrigerant Scale

Microsoft Dynamics SL Web Apps

PC-1 Programmable Controller

welded steel PIPE Nipple price sheet

MD Power Supply -48Vdc +Bias Tee

Process Line Control Solutions. Rockwell Automation Drive Systems

Installation Manual. Omnicell. Model: 9102 FB by Fairbanks Scales, Inc. Revision 4 08/16 All rights reserved

To Our Prospective Customer:

SBF-P 2000 & SBF-P 2254 FLAT TOP CHAIN CONVEYORS

WARRANTY GENERAL POLICY AND RETURN GOODS PROCEDURE. For Original Equipment Manufacturers Only

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Metering Procedures for PA Renewable Energy Credits (MPREC)

Microsoft Dynamics GP. Shipping Documents

ER6-SERIES1:6 SERVICE MANUAL

Installation Manual. All-In-One Shower Panel System. Copyright ShopRangeHoods.com 2016 Office: +1 (626)

how to accept freight and handle claims

Mag-FLEX Probe Low Level Water Float Kit

AA2-M CONTROLLER IMPORTANT!!!!

QA-ES Automation Bundle

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

ISIMET. E Series Enclosure. Custom Assemblies Installation, Maintenance, and Operation Instructions

92831 TEL: (714) FAX:

Instruction Manual HI Portable ph/ec/tds/ C Meters

Instruction Notes for LimiTrol 104A PC512 & 104A PC524

Transcription:

Sageon Site Monitor (SSM) Application Note AN103-4012-00, Issue 3 UNIPOWER, LLC 3900 Coral Ridge Drive Coral Springs, FL 33065 Phone: +1-954-346-2442 Toll Free: 1-800-440-3504 Web site http://www.unipowerco.com

RECEIVING INSTRUCTIONS & GENERAL EQUIPMENT INFORMATION Please Note: For your protection, the following information and the product manual should be read and thoroughly understood before unpacking, installing, or using the equipment. UNIPOWER, LLC presents all equipment to the delivering carrier securely packed and in perfect condition. Upon acceptance of the package from us, the delivering carrier assumed responsibility for its safe arrival to you. Once you receive the equipment, it is your responsibility to document any damage the carrier may have inflicted, and to file your claim promptly and accurately. 1. PACKAGE INSPECTION 1.1 Examine the shipping crate or carton for any visible damage: punctures, dents, and any other signs of possible internal damage. 1.2 Describe any damage or shortage on the receiving documents, and have the carrier sign their full name. 1.3 If your receiving freight bill notes that a Tip-N-Tell is attached to your freight, locate it. If the Tip-N- Tell arrow has turned even partially blue, this means the freight has been tipped in transport. Make sure the carrier notes this on your receipt before you sign for the freight. 2. EQUIPMENT INSPECTION 2.1 Within fifteen days, open the crate and inspect the contents for damages. While unpacking, be careful not to discard any equipment, parts, or manuals. If any damage is detected, call the delivering carrier to determine appropriate action. They may require an inspection. *SAVE ALL SHIPPING MATERIAL FOR THE INSPECTOR TO SEE! 2.2 After the inspection has been made, call UNIPOWER. We will determine if the equipment should be returned to our plant for repair, or if some other method would be more expeditious. If it is determined that the equipment should be returned to UNIPOWER, ask the delivering carrier to send the packages back to UNIPOWER at the delivering carrier's expense. 2.3 If repair is necessary, we will invoice you for the repair so that you may submit the bill to the delivering carrier with your claim form. 2.4 It is your responsibility to file a claim with the delivering carrier. Failure to properly file a claim for shipping damages may void warranty service for any physical damages later reported for repair. 3. HANDLING Equipment can be universally heavy or top-heavy. Use adequate humanpower or equipment for handling. Until the equipment is securely mounted, be careful to prevent the equipment from being accidentally tipped over. 4. NAMEPLATE Each piece of UNIPOWER equipment is identified by a part number on the nameplate. Please refer to this number in all correspondence with UNIPOWER. 5. INITIAL SETTINGS All equipment is shipped from our production area fully checked and adjusted. Do not make any adjustments until you have referred to the technical reference or product manual. AN103-4012-00, Issue 3 i

6. SPARE PARTS To minimize downtime during installation or operation, we suggest you purchase spare fuses, circuit boards and other recommended components as listed on the Recommended Spare Parts List in the back of the product manual. If nothing else, we strongly recommend stocking spare fuses for all systems. Issue 3 All Page(s) Altered Description Updated UNIPOWER logo & contact information. See PCO# 44448. Issued by / Date WD 6/26/17 PROPRIETARY AND CONFIDENTIAL The information contained in this product manual is the sole property of UNIPOWER, LLC. Reproduction of the manual or any portion of the manual without the written permission of UNIPOWER, LLC is prohibited. Copyright UNIPOWER, LLC 2015 DISCLAIMER Data, descriptions, and specifications presented herein are subject to revision by UNIPOWER, LLC without notice. While such information is believed to be accurate as indicated herein, UNIPOWER, LLC makes no warranty and hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further, because the product(s) featured herein may be used under conditions beyond its control, UNIPOWER, LLC hereby disclaims and excludes all warranties, express, implied, or statutory, including any warranty of merchantability, any warranty of fitness for a particular purpose, and any implied warranties otherwise arising from course of dealing or usage of trade. The user is solely responsible for determining the suitability of the product(s) featured herein for user s intended purpose and in user s specific application. Throughout the remainder of this manual, UNIPOWER will mean UNIPOWER, LLC. PERSONNEL REQUIREMENTS Installation, setup, operation, and servicing of this equipment should be performed by qualified persons thoroughly familiar with this Product Manual and Applicable Local and National Codes. A copy of this manual is included with the equipment shipment. Table of Contents 1.0 Introduction... 1 2.0 Applications... 1 3.0 Example Installation... 1 4.0 System Configuration... 2 5.0 Electrical Specification... 2 6.0 Physical Specification... 3 AN103-4012-00, Issue 3 ii

1.0 INTRODUCTION The Sageon Site Monitor (SSM) is an auxiliary module for the Sageon DC Power Plant. The SSM provides additional I/O for the power plant enabling users to monitor the status of additional equipment through the Sageon system. The SSM includes twelve digital inputs and eight analog inputs for monitoring devices such as site security (door and window magnetic switches), AC Inverter status and alarms, Generator status (fuel level, oil pressure), and HVAC status and alarms. Also included are four voltage free (dry), Form C control output relays. The control relays can be automatically activated in response to an event on any of the SSM digital or analog input (configurable by the user), or operated manually from a PC running SageView. 2.0 APPLICATIONS The SSM provides a simple, integrated solution to many common application challenges eliminating the need to purchase separate monitoring equipment. Using the remote communication capabilities and SageView software, the Sageon system can be remotely monitored, allowing the appropriate response to site events. Typical applications include: Integration of site alarms Integration of Inverter status Individual load monitoring Integration of auxiliary equipment status 3.0 EXAMPLE INSTALLATION In this example the auxiliary site equipment is integrated into the site monitor. The I/O for this application include: Analog Inputs Generator fuel level Generator output voltage, current, and frequency Inverter output voltage, current, and frequency Digital Inputs Window and door opening sensors HVAC alarms Digital Outputs NOC alarm generation Local alarms Strobe lights POWER PLANT 4 C/O RELAY CONTACT OUTPUTS Expansion module cable to SCU SEN HVAC f I SEN 12 DIGITAL INPUTS V SSM INVERTERS V I f FUEL 8 ANALOG INPUTS GENERATOR DIESEL SEN FUEL LEVEL AN103-4012-00, Issue 3 1

4.0 SYSTEM CONFIGURATION The SSM is easily configured using the SageView program included with each Sageon DC Power Plant. The Site Monitor configuration screen is pictured below and provides a simple, intuitive user interface. Each input has a user-defined label field (up to 8 characters) to describe its function. If a label field is left blank, the corresponding input is treated as not used. Analog input fields also include a two-character field for the description of the units of measure as well as high and low alarm thresholds. Scaling factor for analog inputs are set-up for 0 volts (0% F.S.) to 4 volts (100% F.S.). The type of digital input source (normally open or normally closed) is user definable by selecting the appropriate check box. Each discrete output can be automatically generated based on any combination of discrete and analog inputs. 5.0 ELECTRICAL SPECIFICATION Analog inputs Number of inputs: 8 Input Range: 0 to +4Vdc Full Scale, Over-voltage and reverse polarity protected. Configuration: Scaling factor, low and high alarm levels are user programmable. Electrical Isolation: Non-isolated. Each analog input source must be isolated. Digital inputs Number of inputs: 12 Source type: Voltage free (dry) contact closure Active state: User defined (active open or active closed) Electrical Isolation: Non-isolated. Each digital input source must be isolated. Digital outputs Number of outputs: 4 Output type: Voltage free (dry) 1 Form C relay contacts Output rating: 1A@30VDC General Power Source: Self powered from the Sageon Interface Board Plant Connection:16 conductor cable to the Sageon Interface Board Maximum Distance: 30 feet (9.14 meters) AN103-4012-00, Issue 3 2

6.0 PHYSICAL SPECIFICATION Module Dimensions (approx): 5.11 x 9.37 x 3.14 (130 x 238 x 80) (DxWxH) AN103-4012-00, Issue 3 3