Reinforced Concrete Design. A Fundamental Approach - Fifth Edition

Similar documents
Reinforced Concrete Column Design

Reinforced Concrete Design. Lecture no. 1

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: MMFX TECHNOLOGIES A COMMERCIAL METALS COMPANY

mortarless masonry Design Manual Part 1 (IS 456:2000) Section 1 Page 1 IS 456:2000 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Column: Part 2 Courtesy of Dr. Latifee s IMI research group, Text books and others

Appendix M 2010 AASHTO Bridge Committee Agenda Item

10.5 ECCENTRICALLY LOADED COLUMNS: AXIAL LOAD AND BENDING.

Basic quantities of earthquake engineering. Strength Stiffness - Ductility

Environmental Engineering Concrete Structures - Introduction. William A. Wallace, P.E., SECB

Reliability-based Calibration of Bridge Design Codes. Andrzej S. Nowak

Section A A: Slab & Beam Elevation

three design codes, building codes Structural Requirements Structure Requirements Structure Requirements serviceability efficiency

CE 315: Design of Concrete Structures I

three design codes, building codes APPLIED ACHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2019 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

VARIOUS TYPES OF SLABS

BEAMS: COMPOSITE BEAMS; STRESS CONCENTRATIONS

twelve design methods, structural codes ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2017 lecture ARCH 614

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

Serviceability considerations

three design codes, building codes Structural Requirements Structure Requirements Structure Requirements serviceability efficiency

BS EN :2004 EN :2004 (E)

Masonry and Cold-Formed Steel Requirements

Supplemental Plan Check List for Concrete Special Moment Resisting Frame

EGCE 406: Bridge Design

Development Length, Lap Splices and curtailment of reinforcement

Beam-column joint tests with grade 500E reinforcing

CHAPTER 11: PRESTRESSED CONCRETE

CHAPTER 5 FINITE ELEMENT MODELLING

ACI Code Revisions Impact on StructurePoint Software

CE 221: MECHANICS OF SOLIDS I CHAPTER 3: MECHANICAL PROPERTIES OF MATERIALS

MECHANICS OF MATERIALS. Mechanical Properties of Materials

PRESTRESSED CONCRETE STRUCTURES. Amlan K. Sengupta, PhD PE Department of Civil Engineering Indian Institute of Technology Madras

COLUMNS 1- Definition: The Egyptian code defines columns as : 2- Types of concrete columns

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS SPRING 2019 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

Flexural Analysis and Design of Beams. Chapter 3

A COMPARATIVE STUDY OF PROBABILITY OF FAILURE OF CONCRETE IN BENDING AND DIRECT COMPRESSION AS PER IS 456:2000 AND AS PER IS 456:1978

Sabah Shawkat Cabinet of Structural Engineering 2017

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

Rajan s Book Chapter 3: Structural Design Fundamentals

Ce 479 Reinforced Masonry Fall 2005

ten reinforced concrete construction Concrete Concrete Materials Concrete Construction columns beams slabs domes footings

Chapter 2 Notation and Terminology

twenty three Masonry Construction 1 APPLIED ARCHITECTURAL STRUCTURES: DR. ANNE NICHOLS FALL 2018 lecture STRUCTURAL ANALYSIS AND SYSTEMS ARCH 631

DEVELOPMENT, SPLICES, AND SIMPLE SPAN BAR CUTOFFS

Pretensioned concrete members are widely used in

CHAPTER 10: GENERAL STRUCTURAL DETAILS

PRESTRESSED CONCRETE STRUCTURES UNIT I INTRODUCTION THEORY AND BEHAVIOUR

Design Values of Materials

10-COLUMNS: 10.1 Introduction.

USE OF 500 GRADE STEEL IN THE DESIGN OF REINFORCED CONCRETE SLAB. Prof. M. Shafiul Bari, Ph.D Department of Civil Engg., BUET

Questions with Solution

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

How to Design a Singly Reinforced Concrete Beam

fifteen steel construction: materials & beams ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2016 lecture

CVEN 483. Structural System Overview

CHAPTER 7: SERVICEABILITY LIMIT STATES

111 MORGAN ST. Ryan Friis

Class Topics & Objectives

NCMA TEK. TEK 14-5A Structural (2006) LOADBEARING CONCRETE MASONRY WALL DESIGN

Flexure and Serviceability Limit State

Lightweight Steel Framing. Composite DeltaStud Load Tables

Analytical prediction of tension force on stirrups in concrete beams longitudinally reinforced with CFRP bars

CHAPTER 2. Design Formulae for Bending

Continuous Beam Design with Moment Redistribution (ACI )

Design of Reinforced Concrete Slabs

Structural Reliability of Existing Structures: A Case Study Z. Sakka, I. Assakkaf, T. Al-Yaqoub, J. Parol

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

Originally Issued: 05/10/2013 Revised: 06/28/2018 Valid Through: 06/30/2019

How Loads Are Distributed

mortarless Design Manual Part 1 (AS 3600:2009) Section 1 Page 1 AS 3600:2009 PLAIN AND REINFORCED CONCRETE - CODE OF PRACTICE

Moment curvature analysis of concrete flexural members confined with CFRP grids

JULY 2014 LRFD BRIDGE DESIGN 5-1

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group

The strength of a material depends on its ability to sustain a load without undue deformation or failure.

VERIFICATION OF MASONRY DESIGN SOFTWARE NATIONAL CONCRETE MASONRY INSTITUTE PHASE III

Structural design criteria

OVERALL STRUCTURAL SYSTEM

Supplemental Structural Correction Sheet Steel Moment Frame Design (2017 LABC)

CHAPTER 11 Bar Cutoff

ARCH 331. Study Guide for Final Examination

TECH FACTS. Formulas for Success Innovative Ways to Reinforce Slabs-On-Ground

Structural Characteristics of New Composite Girder Bridge Using Rolled Steel H-Section

Structural Behaviour and Detailing

Seismic Detailing of RC Structures (IS: )

Appendix B Flexural Resistance of Members with Reinforcing Bars Lacking Well-Defined Yield Plateau

ADAPT PT7 TUTORIAL FOR BEAM FRAME 1

3. Bond, Anchorage and Shear This chapter will discuss the following topics:

> 0. 1 f, they are treated as beam-columns.

DESIGN OF REINFORCED CONCRETE STRUCTURES THIRD YEAR COURSE (JUNIOR COURSE) DR. SALAH R. AL-ZAIDEE

Applications due by March 15, 2008 Results due by June 15, 2008

Concrete Cracking. ε ctr = f ctr / E c = 0.6 / 4400 = x 10-3

Chapter 4 MECHANICAL PROPERTIES OF MATERIAL. By: Ardiyansyah Syahrom

A ROAD MAP FOR DEVELOPING LRFD SPECIFICATIONS FOR RAILROAD BRIDGES

Devil is in the Details. Brian Crowder, P.E.

30 kip/ft (Dead load) 5 ft. 20 ft

AASHTO LRFD Seismic Bridge Design. Jingsong Liu July 20, 2017

Transcription:

CHAPTER REINFORCED CONCRETE Reinforced Concrete Design A Fundamental Approach - Fifth Edition Fifth Edition REINFORCED CONCRETE A. J. Clark School of Engineering Department of Civil and Environmental Engineering 4 SPRING 2004 By Dr. Ibrahim. Assakkaf ENCE 454 Design of Concrete Structures Department of Civil and Environmental Engineering University of Maryland, College Park CHAPTER 4. REINFORCED CONCRETE Slide No. 1 Introduction Concrete is weak in tension but strong in compression. Therefore, reinforcement is needed to resist the tensile stresses resulting from the applied loads. Additional reinforcement sometimes added to the compression zone to reduce longterm deflection.

CHAPTER 4. REINFORCED CONCRETE Slide No. 2 Steel reinforcement consists of Bars Wires Welded wire fabric The most important properties of steel are: Young s Modulus (Modulus of Elasticity), E Yield Strength, f y Ultimate Strength, f u Steel Grade Designation. Size or Diameter of the bar or wire. CHAPTER 4. REINFORCED CONCRETE Slide No. 3 Steel is a high-cost material compared with concrete. It follows that the two materials are best used in combination if the concrete is made to resist the compressive stresses and the steel the tensile stresses. Concrete cannot withstand very much tensile stress without cracking.

CHAPTER 4. REINFORCED CONCRETE Slide No. 4 Reinforced Concrete Beam Figure 1 d b Compression. Tension d - x x b C 1 x 2 N.A. σ F y n A s (a) (b) (c) CHAPTER 4. REINFORCED CONCRETE Slide No. 5 It follows that tensile reinforcement must be embedded in the concrete to overcome the deficiency. Forms of Steel Steel Reinforcing Bars Welded wire fabric composed of steel wire. Structural Steel Shapes Steel Pipes.

CHAPTER 4. REINFORCED CONCRETE Slide No. 6 Deformed Bar CHAPTER 4. REINFORCED CONCRETE Slide No. 7 Bond between Concrete and Steel To increase the bond, projections called deformations are rolled on the bar surface as shown in Fig. 1. Reinforcing Bars (rebars) The specifications for steel reinforcement published by the American Society for Testing and Materials (ASTM) are generally accepted for steel used in reinforced concrete construction in the United States and are identified in the ACI Code.

CHAPTER 4. REINFORCED CONCRETE Slide No. 8 Yield Stress for Steel Probably the most useful property of reinforced concrete design calculations is the yield stress for steel, f y. A typical stress-strain diagram for reinforcing steel is shown in Fig. 2a. An idealized stress-strain diagram for reinforcing steel is shown in Fig. 2b. CHAPTER 4. REINFORCED CONCRETE Slide No. 9 Figure 2. Typical Stress-Strain Curve for Steel Elastic region Elastic region Stress F y Stress F y Stress Slope = E = Strain ε y Strain (a) As Determined by Tensile Test ε y Strain (b) Idealized

CHAPTER 4. REINFORCED CONCRETE Slide No. 10 Figure 3. Typical Stress-Strain Diagrams for Various Steel CHAPTER 4. REINFORCED CONCRETE Slide No. 11 Modulus of Elasticity or Young s Modulus for Steel The modulus of elasticity for reinforcing steel varies over small range, and has been adopted by the ACI Code as E = 29,000,000 psi = 29,000 ksi = 200 10 6 MPa

CHAPTER 4. REINFORCED CONCRETE Slide No. 12 Steel Grades and Strengths Table 1 gives reinforcement-grade strengths. Geometrical Properties Table 2 provides various sizes of bars in US Customary units, while Table 3 gives the sizes in Metric Units. CHAPTER 4. REINFORCED CONCRETE Slide No. 13 Table 1. Reinforced Grades and Strengths 1982 Standard Type Billet steel (A615) Grade 40 Grade 60 Axial steel (A617) Grade 40 Grade 60 Low-carbon steel (A706) Grade 60 Deformed wire Reinforced Fabric Smooth wire Reinforced Fabric Minimum Yield Point or Yield Strength, f y (psi) 40,000 60,000 40,000 60,000 60,000 75,000 70,000 70,000 65,000, 56,000 70,000 90,000 70,000 90,000 80,000 85,000 80,000 85,000 75,000, 70,000 Ultimate Strength, f u (psi)

CHAPTER 4. REINFORCED CONCRETE Slide No. 14 Table 2. ASTM Standard - English Reinforcing Bars Bar Designation Diameter in Area in 2 Weight lb/ft #3 [#10] 0.375 0.11 0.376 #4 [#13] 0.500 0.20 0.668 #5 [#16] 0.625 0.31 1.043 #6 [#19] 0.750 0.44 1.502 #7 [#22] 0.875 0.60 2.044 #8 [#25] 1.000 0.79 2.670 #9 [#29] 1.128 1.00 3.400 #10 [#32] 1.270 1.27 4.303 #11 [#36] 1.410 1.56 5.313 #14 [#43] 1.693 2.25 7.650 #18 [#57] 2.257 4.00 13.60 Note: Metric designations are in brackets CHAPTER 4. REINFORCED CONCRETE Slide No. 15 Table 3. ASTM Standard - Metric Reinforcing Bars Bar Designation Diameter mm Area mm 2 Mass kg/m #10 [#3] 9.5 71 0.560 #13 [#4] 12.7 129 0.994 #16 [#5] 15.9 199 1.552 #19 [#6] 19.1 284 2.235 #22 [#7] 22.2 387 3.042 #25 [#8] 25.4 510 3.973 #29 [#9] 28.7 645 5.060 #32 [#10] 32.3 819 6.404 #36 [#11] 35.8 1006 7.907 #43 [#14] 43.0 1452 11.38 #57 [#18] 57.3 2581 20.24 Note: Metric designations are in brackets

CHAPTER 4. REINFORCED CONCRETE Slide No. 16 Reinforcing Bars (rebars) These bars are readily available in straight length of 60 ft. The bars vary in designation from No. 3 through No. 11 With additional bars: No. 14 and No. 18 CHAPTER 4. REINFORCED CONCRETE Slide No. 17 Bar Spacing and Concrete Cover for Steel It is necessary to guard against honeycombing and ensure that the wet concrete mix passes through the reinforcing steel without separation. Usually aggregate size in structural concrete contains ¾-in (19 mm) diameter coarse aggregate. Therefore, minimum allowable bar spacing and minimum required cover are needed.

CHAPTER 4. REINFORCED CONCRETE Slide No. 18 Bar Spacing and Concrete Cover for Steel Also, to protect the reinforcement steel from corrosion and loss of strength in cases of fire, the ACI Code 318 required minimum concrete cover: Clear distance between parallel bars in layers must not be less than bar diameter d b or 1 in. (25.4 mm). Clear distance between longitudinal bars in columns must not be less than 1.5d b or 1.5 in. Minimum clear cover in cast-in-place concrete beams and columns should not be less than 1.5 in (38.1 mm) when there is no exposure to weather or contact with ground. CHAPTER 4. REINFORCED CONCRETE Slide No. 19 Bar Spacing and Concrete Cover for Steel Bar Spacing 12 in. 20 in. 4-#9 bars 17.5 in. Spacing Clear Cover

CHAPTER 4. REINFORCED CONCRETE Slide No. 20 Concrete Structural Systems Floor Slabs Beams Columns Walls Foundations CHAPTER 4. REINFORCED CONCRETE Slide No. 21 Reliability The reliability of an engineering system can be defined as the system s ability to fulfill its design functions for a specified period of time. In the context of this course, it refers to the estimated percentage of times that the strength of a member will equal or exceed the maximum loading applied to that member during its estimated life (say 25 years).

CHAPTER 4. REINFORCED CONCRETE Slide No. 22 Reliability Motivation Assume that a designer states that his or her designs are 99.6 percent reliable (this is usually the case obtained with most LRFD design). If we consider the designs of 1000 structures, this does not mean that 4 of the 1000 structures will fall flat on the ground, but rather it means that those structures at some time will be loaded into the plastic range and perhaps the strain hardening range. So excessive deformation and slight damage might occur, but not a complete failure. CHAPTER 4. REINFORCED CONCRETE Slide No. 23 Load and Resistance Factor Design (LRFD) Specifications In the previous example, it would be desirable to have 100% reliability. However, this is an impossible goal statistically. There will always be a chance of failure (unreliability), say 2 or 3 %. The goal of the LRFD Specification was to keep this to very small and consistent percentage.

CHAPTER 4. REINFORCED CONCRETE Slide No. 24 Load and Resistance Factor Design (LRFD) Specifications To do this, the resistance or strength R of each member of concrete structure as well as the maximum loading W, expected during the life of the structure, are computed. A structure then is s said to be safe if R W (1) CHAPTER 4. REINFORCED CONCRETE Slide No. 25 LRFD Specifications The basic criterion for strength design may be expressed as Strength furnished Strength required (2) All members and all sections of members must be proportioned to meet this criterion. Eq. 1 can be thought of as a supply and a demand.

CHAPTER 4. REINFORCED CONCRETE Slide No. 26 LRFD Specifications The supply is considered as the strength furnished, while the demand as the strength required. The required strength may be expressed in the forms of design loads or their related moments, shears, and forces. Design loads may be defined as service loads multiplied by their appropriate factors. CHAPTER 4. REINFORCED CONCRETE Slide No. 27 LRFD Specifications General Form m φr n γ W (3) i ni i= 1 Where φ = strength reduction factor γ i = load factor for the i th load component out of n components R n = nominal or design strength (stress, moment, force, etc.) W ni = nominal (or design) value for the i th load component out of m components

CHAPTER 4. REINFORCED CONCRETE Slide No. 28 LRFD Specifications Eq. 3 is the basis for Load and Resistance Factor Design (LRFD) for concrete structural members. This equation uses different partial safety factors for the strength and the load effects. The load factors are usually amplifying factors (>1), while the strength factors are called reduction factors (<1). CHAPTER 4. REINFORCED CONCRETE Slide No. 29 Probability Based-design Approach Versus Deterministic Approach m m R n W ni φrn γ iwni FS i= 1 i= 1 ASD LRFD According to ASD, one factor of safety (FS) is used that accounts for the entire uncertainty in loads and strength. According to LRFD (probability-based), different partial safety factors for the different load and strength types are used.

CHAPTER 4. REINFORCED CONCRETE Slide No. 30 LRFD Specifications The actual values of R and W are random variables and it is therefore impossible to say with 100% certainty that R is always equal or greater than W for a particular concrete structure. No matter how carefully a structure is designed, there will be always some chance that W exceeds R as shown in Figure 4. CHAPTER 4. REINFORCED CONCRETE Slide No. 31 Density Function Figure 4 ( g = R W ) < 0 Area (for g < 0) = Failure probability Load Effect (L) (W) Strength (R) Origin 0 Random Value

CHAPTER 4. REINFORCED CONCRETE Slide No. 32 Reliability (safety) Index β A measure of reliability can be defined by introducing a parameter β, called the reliability index. β can be computed using structural reliability theory and knowledge of the first and second moment statistical characteristics (i.e., mean and COV) for both the strength and load variables. CHAPTER 4. REINFORCED CONCRETE Slide No. 33 Reliability (safety) Index β (cont d) For two variables and linear performance function, the reliability index b can be defined as the shortest distance from the origin to the failure line as shown in Fig. 5. Mathematically, it can be expressed as β µ µ R W = (4) 2 2 σ R σw µ = mean value of strength or load variable σ = standard deviation of strength or load variable

CHAPTER 4. REINFORCED CONCRETE Slide No. 34 Figure 5 Reliability (safety) Index β (cont d) L' W Failure Region Design Point Failure Line g = 0 β Survival Region R' The reliability index β is the shortest distance from the origin to the failure surface. CHAPTER 4. REINFORCED CONCRETE Slide No. 35 Reliability (safety) Index β (cont d) The important relationship between the reliability index β and the probability of failure P f is given by ( ) P = 1 Φ β (5) f where Φ(.) = cumulative probability distribution function of the standard normal distribution

CHAPTER 4. REINFORCED CONCRETE Slide No. 36 LRFD Advantages Provides a more rational approach for new designs and configurations. Provides consistency in reliability. Provides potentially a more economical use of materials. Allows for future changes as a result of gained information in prediction models, and material and load characterization. Easier and consistent for code calibration. CHAPTER 4. REINFORCED CONCRETE Slide No. 37 ACI Load Factors and Safety Margins General Principles The γ load factors and the φ strength reduction factors give an overall safety factor based on load types such as γ 1 D + γ 2L 1 SF = (6) D + L φ where φ is the strength reduction factor and γ 1 and γ 2 are the respective load factors for the dead load D and the live load L.

CHAPTER 4. REINFORCED CONCRETE Slide No. 38 ACI Load Factors and Safety Margins ACI Load Factors U The ACI design loads U (factored loads) have to be at least equal to the value as obtained by the following equation U = φr n = Maximum of Load Combinations = m i= 1 γ W i ni The load combinations are specified by ACI and given in the next slide (ACI Eqs. 9-1 to 7). (7) CHAPTER 4. REINFORCED CONCRETE Slide No. 39 ACI Load Factors and Safety Margins ACI Load Combinations ( D )) U = 1.4 + F (8a) ( D + F + T ) + 1.6( L + H ) 0.5( L or S R) U = 1.2 + r or (8b) ( L or S or R) ( 1.0L or 0. W ) U = 1.2D + 1.6 r + 8 (8c) ( L or S R) U = 1.2D + 1.6W + 0.5L + 1.0 r or (8d) U = 1.2D + 1.0E + 1.0L + 0. 2S (8e) U = 0.9D + 1.6W + 1. 6H (8f) U = 0.9D + 1.0E + 1. 6H (6g) where D = dead load; E = earthquake load; F = lateral fluid pressure load; H = load due to the weight and lateral pressure of soil and water in soil; L = live load; L r = roof load; R = rain load; S = snow load; T = self-straining force such as creep, shrinkage, and temperature effects; W = wind load.

CHAPTER 4. REINFORCED CONCRETE Slide No. 40 ACI Load Factors and Safety Margins The load factors γ s attempt to assess the possibility that prescribed service loads may be exceeded. Obviously, a live load is more apt to be exceeded than a dead load, which is largely fixed by the weight. CHAPTER 4. REINFORCED CONCRETE Slide No. 41 Design Strength Versus Nominal Strength The strength of a particular structural unit calculated using the current established procedures is termed nominal strength. For example, in the case of a beam, the resisting moment capacity of the section calculated using the equations of equilibrium and the properties of concrete and steel is called nominal resisting moment capacity M n of the section.

CHAPTER 4. REINFORCED CONCRETE Slide No. 42 Design Strength Versus Nominal Strength This nominal strength is reduced using a strength factor φ to account for inaccuracies in construction, such as in the dimensions or position of reinforcement or variation in properties. The reduced strength of the member is defined as the design strength of the member. CHAPTER 4. REINFORCED CONCRETE Slide No. 43 Design Strength Versus Nominal Strength Strength Reduction Factor The strength reduction factor φ provide for the possibility that small adverse variation in material strength, workmanship, and dimensions may combine to result in undercapacity.

CHAPTER 4. REINFORCED CONCRETE Slide No. 44 Design Strength Versus Nominal Strength ACI Code Provisions In assigning strength reduction factors, the degree of ductility and the importance of the member as well as the degree of accuracy with which the strength of the member can be established are considered. The ACI Code provides for these variables by using the following φ factors as provided in Table 4. CHAPTER 4. REINFORCED CONCRETE Slide No. 45 Design Strength Versus Nominal Strength Structural Element Beam or slab; bending or flexure Columns with ties Columns with spirals Columns carrying very small axial load (refer to Chapter 9 for more details) Beam: shear and torsion Table 4. Resistance or Strength Reduction Factors Factor φ 0.90 0.65 0.75 0.65 0.9 or 0.70 0.9 0.75

CHAPTER 4. REINFORCED CONCRETE Slide No. 46 Design Strength Versus Nominal Strength ACI Code Provisions When the word design is used throughout the ACI Code, it indicates that the load factors are included. The subscript u is used to indicate design loads, moments, shears, and forces. For example, the design load wu =1.2wDL + 1. 6w and the required or design moment strength for dead and live loads is M u = 1.2M DL + 1. 6M LL where 1.2 and 1.6 are the load factors. LL CHAPTER 4. REINFORCED CONCRETE Slide No. 47 Design Strength Versus Nominal Strength ACI Requirements for Dead and Live Loads For dead and live loads, the ACI Code specifies design loads, design shears, and design moments be obtained from service loads by the using the relation U = 1.2D + 1. 6L (9)

CHAPTER 4. REINFORCED CONCRETE Slide No. 48 Design Strength Versus Nominal Strength ACI Requirements for Strength The ACI Code stipulates that the strength (moment, shear, force) furnished shall meet the following requirements φ R n 1.2D + 1. 6L (10) where φ = strength reduction factor as provided in Table 4 R n = nominal strength (stress, moment, force, etc.) φ R n = design strength