Health Sciences Campus Biomedical Waste Management Standard Operating Procedure (SOP)

Similar documents
BIOMEDICAL WASTE MANAGEMENT POLICY

Dartmouth College. Institutional Biosafety Committee. Biohazardous Waste Disposal Guide IBC Approved: 4/5/17

Dartmouth College. Institutional Biosafety Committee. Biohazardous Waste Disposal Guide IBC Approved: 10/3/18

Biomedical Waste Management Guide

Biological and Regulated Medical Waste Plan

Biosafety Checklist. 07-BiosafetyChecklist-LTC-SOP-v2.0-17Feb of 6

Animal cell and tissue culture. Lab 1

Policy & Procedure Manual

LABORATORY WASTE DISPOSAL GUIDE

WHO NEEDS TO KNOW THIS PROGRAM All NYU employees that generate, handle or transport RMW should be familiar with this written program.

Medical, Pathological and Low-level Radioactive Waste Management Plan for Incinerator Revised 3-08

Biosafety Level 1 ( BSL1 ) and Biosafety Level 2 ( BSL2 ) Biological Waste Management Guideline

PI s Name Date Bldg./Rm#

Laboratory Close-Out Guidelines

Infectious Waste Disposal Procedure 25 PA Code 284 Ursinus College Collegeville, PA 19426

Biomedical Waste Management Plan

Regulated Medical Waste Management and Proper Waste Segregation. State-Specific Information Washington

Biosafety Training. WVU Shared Research Facilities 2012

DEPARTMENT OF BIOLOGICAL SCIENCES MEDICAL/BIOHAZARDOUS WASTE DISPOSAL AUTOCLAVE TRAINING

ENVIRONMENTAL MANAGEMENT GUIDE FOR SMALL LABORATORIES

ENHANCED CONTAINMENT CL2 + (Level 3 practices in a Level 2 lab)

Biosafety Level 2 (BSL-2) Laboratory Guidelines

Biological Safety Program. For. Otterbein University

Amherst College. Health and Safety Manual for the Use of Recombinant DNA and Biological Agents Current as of May 14, 2010

Delaware State University

LABORATORY WASTE MANAGEMENT PROGRAMMES

VIII. Biosafety Laboratory Practices and Equipment

UW LOCAL RISK ASSESSMENT WORKSHEET FOR WORK WITH BIOLOGICAL MATERIALS

PROGRAM FOR THE MANAGEMENT AND DISPOSAL OF RADIOACTIVE WASTE

Radioactive Waste Radiation Safety Orientation Open Source Booklet 7 (June 1, 2018)

Standard Operating Procedure for Fluorouracil in Animals

Guidelines for the Use of Cytotoxic or Chemotherapeutic Drugs

Appendix J. University of Alabama at Birmingham Medical Waste Management Plan

Pathogen Safety Sheet

Biological Waste Disposal Table

2/07. PROCEDURE for DISPOSAL of RADIOACTIVE MATERIALS

Biosafety Level 2 Criteria Based on Biosafety in Microbiological and Biomedical Laboratories (BMBL) 5th Edition

Michigan Small Animal Imaging Resource In Vivo Cellular and Molecular Imaging Center. Department of Radiology. University of Michigan

UNIVERSITY OF NEVADA LAS VEGAS BSL-2 LABORATORY STANDARD OPERATING PROCEDURES (SOPS)

IACUC Standard Operating Procedure SOP : Isolation of Hazardous Chemicals/Agents in Use in Rodents

THE UNIVERSITY OF NEWCASTLE- DISCIPLINE OF MEDICAL BIOCHEMISTRY

You are required to complete this course with a passing score of 85% or higher if you:

SOP BIO-006 USE OF AUTOCLAVE FOR STERILIZATION OF MATERIALS AND BIOLOGICAL WASTE

Animal Facility Biosafety Level 3 Checklist (date: April 16, 1998)

Biological and Regulated Medical Waste Disposal Policy

Biological Materials and Biohazardous/Medical Waste Disposal Program

Vertebrate Animal Biosafety Level 2 Criteria

Laboratory Relocation Guidelines. Overview 2. Laboratory Close Out Contacts..3. Initial Laboratory Close Out Checklist...3

OFFICE OF RESEARCH SAFETY RS104 Lab Closeout Policy

Appendix B: Decommissioning Checklist for Lab Move

Biohazardous/Medical Waste Management and Sharps Procedures

INFECTIOUS/BIOLOGICAL WASTE MANAGEMENT PROTOCOL

Lab Safety, Biological Safety and Bloodborne Pathogen Training

University Health Services Health and Safety

UNIVERSITY OF RICHMOND REGULATED MEDICAL WASTE MANAGEMENT GUIDELINES

The University of Texas at El Paso. Biological Safety Manual

Central Bio-Medical Waste Treatment Facility

Regulated Medical Waste Management and Proper Waste Segregation

Lab Biosafety Self-Audit Form (Applies to all microbial work.)

Contents. Introduction

Safe Operating Procedure

Environment, Health and Safety

NJIT Biological Waste Management for Laboratories. NJIT Environmental Health and Safety Department Spring, 2017

UNIVERSITY OF TOLEDO

Inspection Checklist for BSL-3 Laboratories Non-Smile Resource

AREAS OF RESPONSIBILITY

BIOSAFETY LEVEL 2 PROTOCOLS BIOPROCESS OPTIMIZATION LABORATORY - POULIOT BUILDING, ROOM 1541 ALAIN GARNIER JUNE 2007, LAVAL UNIVERSITY

Standard Operating Procedure Title: Good laboratory practices (GLP) for microbiology and chemistry laboratories

Texas A&M University Commerce April 11, 2014

BIO-MEDICAL WASTE MANAGEMENT (AMENDMENT) RULES -2018

December 2009 CDC-NIH

DUQUESNE UNIVERSITY. Biosafety Guidelines

DUQUESNE UNIVERSITY. Biosafety Guidelines

SOP for Recombinant Viral Work in Animal Facilities

BIOLOGICAL SAFETY BSL- 2 LABORATORY PROCEDURES

WASTE MANAGEMENT GUIDE. Creighton University Environmental Health and Safety

CLEMSON UNIVERSITY LAB CLOSE-OUT POLICY/PROCEDURES FOR HAZARDOUS SUBSTANCES, EQUIPMENT, SUPPLIES, ETC.

To the Principal Investigator:

Location, Location, Location! Environmental Services And Labs/Pathology/Mortuary

To the Principal Investigator:

Disposal of biological waste from containment level 2 laboratories in the WIMM

Inspection Checklist for NIH BL3 Laboratories (7 CFR 331; 9 CFR 121; 42 CFR 73; NIH Guidelines)

WVU IACUC SOP: Radioactive Materials Used in Animal Studies

Laboratory Biosafety Plan

Minimum Safety Equipment. Standard microbiological practices Sink Required

General Guidelines for Users and Visitors to NTU. Animal Research Facility

BIOSAFETY LABORATORY AUDIT Department of Biological Safety University of Kentucky

USP800: A quick summary and disposal. Brenda Denson, Pharm.D.

Location, Location, Location! Environmental Services

BIOSAFETY MANUAL 2014

Biosafety Primer. An introduction to the world of biosafety

Animal Waste carcasses, parts, blood & blood products, and bedding of animals intentionally exposed to pathogens

Western Carolina University Hazardous Waste Program

Standard Microbiological Practices

Environmental Health and Safety Equipment Release Form

LABORATORY CLOSURE AND DECOMMISSIONING POLICY

BIOSAFETY LEVEL LABORATORIES

Biosafety Protocol. Biodesign Swette Center for Environmental Biotechnology Standard Operating Procedures

Laboratory Decontamination and Decommissioning Policy and Procedures. Office of Environmental Health and Safety

Biosafety Program. I. Policy. Authority. Definitions

Transcription:

Health Sciences Campus Biomedical Waste Management Standard Operating Procedure (SOP) NOTE: This SOP for biological waste management does not supersede the requirements for radioactive and/or hazardous chemical waste management. If your waste biomedical waste is mixed waste (i.e. contaminated with chemicals or radioactive materials) that waste will need to be disposed of according to the recommendations of those safety offices. Types of Biomedical Wastes Solid Biomedical Waste (i.e. plasticware, tubing, pipette tips, gloves) Sharps Waste (i.e. needles, glass, scalpels, razor blades) Liquid Biomedical Waste (i.e. cultures, stocks, vaccines) Pathological Waste (i.e. human tissues, blood and other body fluids) Animal Waste (i.e. carcasses, tissues, bedding) Chemotherapy Agent Wastes (i.e. any disposable material that has come into contact with cytotoxic/antineoplastic agents including gloves, vials, IV tubing) Discarded Contaminated Equipment (i.e. centrifuges, shakers, biosafety cabinets) Solid Biomedical Waste Solid biomedical waste should be placed in a biohazard, red-bag lined box (shown to the right), provided by Environmental Services. To request additional biohazardous waste containers, or to request waste pick-ups, please contact 706-721-2434. Liquids or soggy materials should NOT be placed inside the Stericycle red-bag lined boxes. No loose sharp items should be placed in these containers which would puncture the red bags. Do not overfill the boxes. The boxes should be removed when 2/3 full. These containers have a 50 lb. maximum weight limit. 1

Any material of higher hazard ( BSL2) should be decontaminated prior to placement into these containers. BSL2+ designated laboratories should follow this practice. Biohazard waste boxes or containers should not be left in unsecured areas (e.g., in hallways or on loading docks) where non-trained personnel or personnel with unknown health status may encounter them. Biohazardous waste, by definition, is hazardous material and must remain secured at all times Items which are not biological waste or potentially contaminated with biological materials should NOT be placed in the biohazardous waste containers. Do not combine the contents of one box into another or lift the bag out of the box. Alternate intermediary biohazard waste containers can be used, provided that: Containers are clearly demarked as biohazardous waste with color-coded labels (e.g., by using red bags or biohazard stickers). The waste in these containers are removed promptly after use and not allowed to linger in these intermediary waste containers. Containers are capable of being decontaminated and are decontaminated often. No sharps are disposed in these intermediary containers (sharps must be directly placed into authorized sharps containers). The waste is transferred to the authorized waste receptacle by the laboratory staff (not the Environmental Services staff). Sharps Waste There are two types of sharps containers available upon request from Environmental Services. To request additional sharps waste containers, or to request waste pick-ups, please contact 706-721-2434. These are shown below: 2

Each of these containers all comply with OSHA BBP standard requirements dictated for sharps containers. These are: closable, puncture-resistant, leak-proof on the sides and bottom, labeled and/or color-coded. Soggy items and small amounts of liquids (e.g., a few ml of blood remaining in a tube) can be disposed in these containers. Larger volumes of liquids should be handled as liquid waste. Containers should be easily accessible and located close to work areas where sharp materials are used. The containers must be maintained upright. These containers need to be replaced routinely. Do not allow these containers to become overfull. These containers should be closed and removed when 2/3 full. Do not remove the lids from these containers or force objects into them. Liquid Biomedical Waste MUST be decontaminated before disposal according to your laboratory or clinic SOPs. Liquids that have been autoclaved or decontaminated using bleach can be disposed of using the sanitary sewer system. Special procedures may be required to deactivate toxins, prior to disposal. NOTE: Decontamination with a chemical other than bleach may require special disposal procedures; contact the Chemical Safety Office for guidance (706-721- 2663). Caution should be taken not to dispose of any material which may clog sewer disposal pipes. All vacuum aspirator traps/flask MUST have either a filter or secondary overflow two flask disposal system to protect vacuum lines from entry of biological fluids. Pathological Waste Any item which is identifiable as a human or animal body part or an animal carcass needs to be disposed pathological waste. These items must be incinerated. 3

All animal carcasses be packaged and labeled according to LAS/IACUC compliant procedures and placed in one of the necropsy freezers (e.g., in CB- 1344, CA-1105, CA-1126, CA-1135, BG-1135A, CL-1119 or CL-1133) or in the cold storage room (CB-3100). Contact LAS about the proper labeling procedures. For disposal of human tissues or body parts, contact the (706-721-2663) for proper disposal procedures. Animal Waste Proper disposal of animal carcasses is described in the pathological waste section. Animal bedding is disposed of based on the hazards. Contact LAS for the proper disposal procedures. Animal bedding generated from ABSL1 or conventional animal housing can be disposed of in the regular trash. Bedding generated from animals housed in an ABSL2 facility will need to be collected and autoclaved prior to exiting the ABSL2 facility. NOTE: Animal bedding that may contain chemotherapeutic agents, other high hazards chemicals or radioactive materials may require special disposal procedures (i.e. bedding contaminated with chemotherapeutic agents cannot be autoclaved). Chemotherapy Waste Chemotherapy wastes must be incinerated, as per Georgia EPD Chapter 391-3- 4-15. While these agents are often used in clinical therapy, many of these agents may also be used for in vitro and in vivo animal research applications (e.g., Actinomycin D, Mitomycin-C, Streptozotocin, Bleomycin, GM-CSF, Interleukin-2, INF-α, Gleevec). According to GA EPD, chemotherapy wastes include: Any disposable material which has come in contact with cytotoxic/antineoplastic agents (agents toxic to cells) and/or antineoplastic agents (agents that inhibit or prevent the growth and spread of tumors or malignant cells) during the preparation, handling, and administration of such agents. Such waste includes, but is not limited to, masks, gloves, gowns, empty IV tubing bags and vials, and other contaminated materials. The above waste must first be classified as empty which means such quantity that it is not subject to other federal or state waste management regulations prior to being handled as biomedical waste. NOTE: "Empty" is generally defined as containing less than 3% by weight of the total capacity of the container. 4

Stock solutions of these chemicals and items that are heavily contaminated must be disposed of as hazardous waste. Call the Chemical Safety Office (706-721- 2663) for guidelines concerning the disposal of chemical hazardous waste. Discarded Contaminated Equipment Equipment that has come into contact with biohazardous materials will need to be decontaminated prior to disposal, transport, surplus, etc. The method of decontamination is dependent upon the equipment and the biohazard that the equipment has come into contact with. Your laboratory SOPs should indicate a disinfection method suitable for the agents used in your laboratory. If you are unsure of the method to use, contact the (706-721-2663). Be sure to follow the instructions for the disinfectant (i.e. concentration, contact time). The need for gaseous decontamination of a Biosafety cabinet (BSC) must be evaluated by the Biosafety Office prior to moving. Should a BSC require decontamination, arrangements must be made in advance with Laboratory Equipment Services (LES) (706-721-6124) to perform this service before the BSC can be moved. 5