XS-1000i New Sysmex 5-part diff haematology analyser with fluorescence technology

Similar documents
Pushing limits in routine laboratory haematology with the XT-4000i

Examples of body fluid analysis with the XE-5000

Cell analysis and bioimaging technology illustrated

Automated Hematology Analyzer. Small Footprint. Big Difference.

Greater Possibilities By Design

Evaluation of the Automated Immature Granulocyte Count (IG) on Sysmex XE-2100 Automated Haematology Analyser vs. Visual Microscopy (NCCLS H20-A)

Automated Hematology Analyzer. Differentiate with the XT-4000i

BC Auto Hematology Analyzer. A CUTE 5-part

ENUMERATION OF LYMPHOCYTES SUBSETS (IMMUNOPHENOTYPING-IPT) (CD3, CD4, CD8, CD19 & CD16/56)

BC Auto Hematology Analyzer. A CUTE 5-part

CS Automated haemostasis testing. Medium workload high class.

ABX Pentra XL 80. Hematology analyzer. Auto-sampling 5-part Differential Customized Dilution Ratio Integrated Validation Station

Electron microscopy technology of reticulocytes after sorting with

XN Series. What s in it for me? Krista Curcio, MT(ASCP), MBA Product Manager, Hematology Systems Sysmex America, Inc. All rights reserved.

See Brilliant Results

True Walkaway Automated Urinalysis, Chemistry to Microscopy The CLINITEK AUWi System Answers for life.

CellaVision DM96. Automated Digital Cell Morphology

SEED HAEMATOLOGY. SNCS IQAS Online the quality control solution for the haematology laboratory

ABX Pentra DX120. Hematology analyzer. 45 parameters Integrated slide-maker Expert validation system

A Division of Woodley Equipment Company Ltd

Completing the performance picture.

Ruby. A shining example of. Put science on your side. Intended Use:

Quintus 5-part hematology analyzer In-depth, quality-controlled 26-parameter results

Automated Hematology System. Your Complete Choice

Novel POC analysis for determination of total and 5-part differential WBC count among a US population, in comparison to Beckman Coulter LH750

Immature Granulocyte Enumeration Our Journey from Manual to Automated Reporting

NovoCyte Flow Cytometer

BC-6800 Auto Hematology Analyzer. Small Cube, Big Difference

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Assistant Product Manager BDBiosciences

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

CFSE Cell Division Assay Kit

E. coli Phagocytosis Assay Kit

SF Cube. Exclusive Technology, Inclusive Approach. BC-6800 Auto Hematology Analyzer. Cell Analysis Technology

Flow cytometry within reach.

Department of Pathology

Sysmex Educational Enhancement and Development No

Evaluation of the Sysmex XN-550, a Novel Compact Haematology analyser from the XN-L series, compared to the XN-20 system.

BEYOND A BETTER BOX DI-60 INTEGRATED SLIDE PROCESSING SYSTEM. Seamless Integration

The Simple Solution for CBC Testing

Identification of red and white blood cells from whole blood samples using the Agilent 2100 bioanalyzer. Application Note

Automation In Life Sciences and Diagnostics Applications

XN Hematology Case Studies Every Picture Tells a Story

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY

Dry Hematology Analyzer Fast, Simple CBC Analysis Designed for the Point of Care

QUICK REFERENCE GUIDE. Easy operation fast results. Closer to Care.

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY

Starrsed RS. Gold Standard ESR

Changing the world of laboratory developed testing

2. SUMMARY AND EXPLANATION

XN Series. Greater Possibilities by Design What s in it for me? Krista Curcio, MT(ASCP), MBA Product Manager, Hematology Systems

BD FACSMelody. Cell Sorter. The simple solution for consistent, quality results

FLOW CYTOMETRY. CyAn ADP. Analyzer

Applied Biosystem Prism 6700 Automated Nucleic Acid Workstation

Primerdesign TM Ltd. Eubacteria. genesig Easy Kit for use on the genesig q reactions. For general laboratory and research use only

BEYOND A BETTER BOX XN-V SERIES TM MULTISPECIES HEMATOLOGY ANALYZERS. Accelerate Your Multispecies Research Laboratory XN-V IS FOR ANIMAL USE ONLY

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

UNRIVALED SIMPLICITY. Exceptional Ease of Use. The STAR brings new meaning to the word simple

Quality Control: Tips, Troubleshooting, and Tidbits

11/2/2015. Describe the technologies available on the XN-Series and the reason(s) for selection

ITC Hemochron Signature Elite

Features & Benefits Five-part differential on cat, dog, horse, cow, alpaca and llama; three-part differential on the nine other species

PCR SYSTEMS. a new era in high-productivity qpcr. Applied Biosystems ViiA 7 Real-Time PCR System

No-wash, no-lyse detection of phagocytic cells via a phrodo BioParticles functional assay in human whole blood on the

DRM DISPATCHER USER MANUAL

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Phagocytosis Assay Kit (IgG PE)

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

Manual For Blood Cells Atlas Morphology Download

Neutrophil/Monocyte Respiratory Burst Assay Kit

Business Case for Haematology Analyser Replacement Recommendation

OPSIS LiquidLINE KjelROC Analyzer

Tests Circulating Tumor Cell Control Kit

Stains. for blood and bone marrow. Overview of the classic staining methods, fast stain and foil staining. Focussing your hematology targets.

Measuring cell proliferation using the CyQUANT Cell Proliferation Assay with SpectraMax Microplate Readers

Carl Zeiss MicroImaging AIS. Digital Pathology The Future. Andrew Lesniak Director, Product Management

Agilent 2200 TapeStation System ACCELERATE YOUR SAMPLE QC WITH CONFIDENCE

Application Note. Assay Portability on the BD FACSVerse System. Summary. Maria Jaimes, Yibing Wang, Catherine McIntyre, and Dev Mittar

Single-Cell. Defy the Law of Averages

Menu and Throughput to Accommodate Your High-volume Testing Needs

THE FREEDOM TO DISCOVER BOND RX FULLY AUTOMATED IHC AND ISH AND EMERGING TESTS RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES.

norma Hematology family norma Access norma norma Vision Reagents

Size quality report for the Zetasizer Nano

The next generation FT-NIR spectrometer. Innovation with Integrity FT-NIR

Product Fact Sheet Added values XN-CBC and XN-DIFF

PERFECT-COUNT MICROSPHERES

TANGO. ANALYSIS TO GO. Innovation with Integrity. The next generation FT-NIR spectrometer. FT-NIR

CFSE Cell Division Assay Kit

Simplexa EBV Quantitation Standards

LONDON HEALTH SCIENCES CENTRE (LHSC) WORKFLOW COMPARISON STUDY WITH THE AQUIOS CL FLOW CYTOMETER

OPSIS LiquidLINE KjelROC Analyzer

Multi-Purpose Transfection Reagents

Diagnostic Medical Equipment New Revenue for Your Medical Practice

DEFY THE LAW OF AVERAGES. Single-Cell Targeted Gene Expression Analysis

determine optimum instrument settings for their own instruments and establish their own daily values.

OPSIS LiquidLINE KjelROC Distillation Unit

ALL INFECTOLOGY. and now. Gucker, 1947 Wallace Coulter Coulter Orifice, Kamentsky, 1965 Mack Fulwyler sorter BLOOD:

OPSIS LiquidLINE KjelROC Analyzer

InhibiScreen Kinase Inhibitor Assay

Direct Cell Counting Assays for Immuno Therapy

Transcription:

XS-1000i New Sysmex 5-part diff haematology analyser Fig. 1: sysmex xs-1000i Since the introduction of fluorescence technology for leukocyte differentiation by sysmex in the year 1999, thousands of laboratories worldwide have been working with this still novel method in blood diagnostics. During that time, many users have been able to develop jointly with sysmex new parameters and applications which help improving the diagnosis and therapy of patients. And until today, fluorescence-based leukocyte differentiation offers potential for further developments as studies have shown, in sepsis diagnostics for example. Aside from the sysmex high-end haematology analysers of the xe- and xt-series for the medium-sized laboratory, there are now two new haematology analyser systems of the x-class working with this fluorescence technology: xs-1000i and xs-800i. Specially tailored to the requirements of small laboratories with low sample volumes or as backup systems, the xs-1000i and xs-800i are offering proven technology and handling of the x-class coupled with innovative changes. Haematology is fluorescence flow cytometry anywhere But what exactly is so special about the fluorescence technology by sysmex? From a purely technical point of view, the RNA and DNA components in the cell are stained with special fluorescence dyes, patented by sysmex, without destroying the cell. It is thus possible to measure with suitable detectors the nucleic acid percentage of each cell as a physical characteristic of this cell. Thus, the cell nucleus will be analysed together with the cytoplasm which goes far beyond the simple differentiation according to the size and internal density or, respectively, the granularity of the cell. This will be realized with special semiconductor lasers, detectors as well as especially specific reagents. 1/5 XS-1000i new Sysmex 5-part diff haematology analyser 11/2006

The advantage of this technology is its very specific and, at the same time, sensitive detection of immature blood cells and malignant or, respectively, abnormal cells, such as e.g. reactive lymphocytes in the peripheral blood. Due to their proliferation or protein synthesis activity, e.g. within the scope of antibody production, such blood cells naturally have an increased nucleic acid percentage which can be detected by the correspondingly increased fluorescence signal. Precisely that characteristic distinguishes the quality of the fluorescence technology and its reliability in practice: Among many normal blood samples, one pathological sample can thus be filtered out. The following figure illustrates the DIFF scattergram of the new xs-series. In addition to the complete differential blood count of the 5 leukocyte populations, all important warning messages from the high fluorescence area of the scattergram will be generated. Area in which cells with a clearly increased fluorescence signal are detected (e.g. reactive lymphocytes, immature granulocytes or blasts) Monocytes Lymphocytes Neutrophils Eosinophils Basophiles Abb. 3: DIFF scattergram of the xs-series with the 5 leukocyte populations and the area for the warning messages, should the relevant pathological cells be present in the blood However, fluorescence technology does not only offer a reliable warning message with immature or reactive cells. At the same time, it is also a suitable method for excluding negative effects on the differential blood count due to otherwise troubling particles, e.g. lysis-resistant erythrocytes, lipids or technical artefacts such as air bubbles or contaminations. All of the mentioned particles have no nucleic acid components and thus do not provide any detectable fluorescence signal. For this reason, they always come to lie in the dark blue so-called»ghost area«of the scattergram and do not influence the differential blood count. Whether a warning message refers to a morphological abnormality, such as e.g.»blasts?«, or an increased or, respectively, reduced cell count, e.g.»lymphopenia«, all warning messages of the xs-series are principally adjustable to the individual requirements of each laboratory. This does not influence the specificity of the warning messages, but their sensitivity in the detection of pathological samples which can thus be increased or reduced. 2/5

In addition to the fluorescence technology for optimal leukocyte differentiation, other proven methods have also been kept in the xs-series. This includes keeping a separate measuring channel only for the haemoglobin measurement. The detergent here used (sodium lauryl sulphate) does not only lyse the erythrocytes included in the sample, but also the leukocytes. Thus, pronounced leukocytoses are no reason for having to dilute the samples since the measured haemoglobin value is reliable. The same applies for highly lipaemic samples in which the soap-like character of the reagent eliminates disturbing effects of the lipids in the haemoglobin measurement. Ease of handling As with all sysmex instruments, for us, the most important criterion is the development of a robust system with minimum maintenance expenditure for the laboratory. The systems of the xe- and xtseries already require only one daily shutdown which is, moreover, fully automatic. For the xs-series, it was possible to even further reduce the maintenance required by the user: A single push of a button is necessary for the daily 2-minute fully automatic shutdown. And no additional reagent will be required for it. Shutdown: Push the button, wait for 2 minutes, ready! Other functions and menu structures of the software were completely taken over from the other systems of the x-class and partly further simplified in their handling: All measured samples are stored in a central database which includes up to 10,000 results including all graphics. All stored samples can be retrieved at any time by means of comprehensive sorting and filtering criteria, as well as various search functions. The processing status is also evident for every single result validated, printed out or transmitted to the laboratory EDP. Operation and data analysis is performed via a menu for all graphic and numerical results of a sample. Also included are in addition to an overview page for all values of the findings report so-called»research parameters«, such as e.g. the number of immature granulocytes (IG# and IG%). Error messages and validation status of the sample are here also immediately visible. 3/5

The xs-software offers 20 QC files with 300 data items each which are presented in line graphics (L-J chart). Additionally, the most current QC measurement at the time is presented in special, separate so-called radar graphics enabling a quick overview of the QC status of all parameters. Should any parameter drop from the QC, this will be visible at a glance. Every error message by the instrument includes a proposal for a countermeasure which can be confirmed by simply clicking on the»ok«button in the Help window. Thus, the failure can be directly remedied without any loss of time. Maintenance services, replacement of reagents, or measures in case of insufficient sample volume intake can be performed directly via the Help menu. Two different printouts can be generated with the xs-analyser: The standard findings report printout, and a»laboratory internal printout«. With the latter, non-validated results or additional parameters can also be printed out, such as e.g. the values of immature granulocytes. The default settings of both printouts can be individually changed and even expanded, e.g. by the laboratory's logo in the header. If additional data aside from the sample number are known, the xs-system can directly receive these data from the laboratory EDP and store them together with the sample number. Alternatively, however, the data can also be directly entered into the xs-instrument and will then also be available on the findings report. A system for reagents management permits to check at any time which reagents have been replaced when and by whom. At the same time, it is shown when a new reagent is expected to be connected. 4/5 SYSMEX EUROPE GMBH Bornbarch 1, 22848 Norderstedt, Germany Phone +49 (40) 52726-0 Fax +49 (40) 52726-100 www.sysmex-europe.com

20 μl aspiration volume in XS-1000i and XS-800i Technically, both instruments are absolutely identical and structurally similar; only the aspiration method for the blood samples differs. While the xs-1000i analyser takes in blood samples in a closed system where the tube cap is pierced and any direct contact with the sample will be avoided, in the xs-800i analyser, the samples can only be manually aspirated with opened tube. This type of intake is advantageous especially if there are only minimal blood volumes available (such as e.g. in paediatric hospitals) or if microtubes are primarily used. Micro-tubes can of course also be used in the xs-1000i analyser; a special adapter is supplied with all Fig. 4: In the xs-1000i, the tube cap can be pierced to minimize the risk of direct contact with the sample. instruments. In both instruments, the aspiration volume remains equally low in any case: Only 20 μl are used for the complete differential blood count. Both instruments have a novel blood sensor to guarantee at any time precisely the 20 μl aspiration volume and thus the reliability of the analysis results. Fig. 5: In the xs-800i, blood samples can only be analysed manually and in open condition which is advantageous especially for minimal blood volumes. For a higher degree of automation and standardization in the workflow, the xs-1000i analyser furthermore offers the possibility of optionally connecting a sampler. In such a sampler, the samples will then be mixed upside-down and the barcode is read automatically to query the corresponding sample request from the laboratory EDP. 5/5 XS-1000i new Sysmex 5-part diff haematology analyser 11/2006