DIVISION PARKING STRUCTURES

Similar documents
SPACE TYPE: OUTSIDE PARKING (STRUCTURE)

University of New Mexico Environmental Services Design & Development Standard Requirements

Division 34. Transportation

ARTICLE 13 SITE PLAN REVIEW

Facilities Management Service and Support Function Needs

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

DIVISION 2 SITE DEVELOPMENT DESIGN CONSIDERATIONS SECTION DESIGN GUIDELINES DUVAL COUNTY PUBLIC SCHOOLS

DESIGN GUIDELINES FOR MULTI FAMILY AND ATTACHED SINGLE FAMILY INFILL HOUSING

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

260,000 SF Building Profile

TRANSLINK LOGISTICS CENTRE

A/E Design Deliverable Checklist

Expanding Your Development & Investment Perspectives 159,000 SF Building Profile

NC State University Design and Construction Guidelines Division 00 Planning & Design Space Planning

TRANSLINK LOGISTICS CENTRE

March 2018 Progress. Work Completed, Week Ending 3/23/18:

SAN FRANCISCO UNIFIED SCHOOL DISTRICT 2006 PROPOSITION A BOND PROGRAM 300 SENECA NEW ACADEMIC CAMPUS ADDENDUM NO. 1

1.0 Total Points % 2.1 Building Exterior Elements % 2.2 Accessibility % 2.3 Structural %

Exhibit A Library Shell Construction

A/E Design Deliverable Checklist

General: Exterior walks and paved areas constructed in conjunction with new building projects shall conform to the requirements of these guidelines.

B. All roadways per the American Association of State Highway and Transportation Officials, (AASHTO) Standards for local roads.

FACILITY COMPONENTS - MIDDLE SCHOOL

Overbrook Theater / Fruenthal Foundation Art Center. 1.0 Total Points % 2.1 Building Exterior Elements %

Entellus 75 NORTH STREET MERRILL SHERIFF CONSTRUCTION. 181 North 200 West, Suite #4. Bountiful, UT Phone

KINGS MILL Builder Guidelines

AGILITAS Property Development

ORDINANCE NO. AN ORDINANCE AMENDING APPENDIX A OF THE CITY CODE BY ADDING ARTICLE A FOR PLANNED DEVELOPMENT DESIGNATION NO.

CONSTRUCTION TRADES LABORATORY September 30, 2010

This section applies to service areas and loading docks for new construction and major renovations.

Commercial Tax Abatement

ADDENDUM NO Refer to Specifications Section Alternates. Clarifications to alternate descriptions are as follows:

AIRWAYS CROSSING PHASE II BUILDING INFORMATION 5305 McCall Way N.E. T2E 7N7

BUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor

Hodgson Road. Randolph Road Variable Public Right of Way VICINITY MAP NOT TO SCALE. 50' Public Right of Way

Minimum Standards for Construction of Aircraft Hangars MINIMUM STANDARDS FOR CONSTRUCTION OF AIRCRAFT HANGARS

Project Information Session / Meet and Greet # 3

A PPEARANCE REVIEW BOARD

CITY OF THOUSAND OAKS APPROVAL CHECKLIST FOR REFUSE/RECYCLING ENCLOSURES

CIRCLE K SUB-CONTRACTOR BID FORM

National Property Inspections

186 TH AIR REFUELING WING KEY FIELD, MERIDIAN, MS ADDENDUM #1 PERFORMANCE WORK STATEMENT

AUTOMOTIVE SERVICE TECHNOLOGY September 30, 2010

Permit Posting and Inspection Procedures

RATIONALE AND REASONING The following information is provided in response to the issues raised by the Board of Regents at the September 2012 meeting:

SECTION MINOR CONCRETE

Pollutant Sources/Source Controls Checklist A-7

Division 09 FINISHES TABLE OF CONTENTS

RESIDENTIAL BUILDING PLAN REQUIREMENTS

HILLSIDE ELEMENTARY SCHOOL. Overview: Livingston School District Hillside Elementary School

ENVIRONMENTAL HEALTH DIVISION. GUIDELINES FOR: NEW and REMODELDED FOOD STABLISHMENTS

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

ADDENDUM A CONSTRUCTION SPECIFICATIONS

Certificate of Use Application Package

BBL. Corporate Overview. National Rankings MODERN HEALTHCARE TOP DESIGN-BUILD COMPANIES 1

Section X - Miscellaneous

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

Section 32 - Miscellaneous

FRV AE SOLAR PROJECT, WEBBERVILLE, TX SPECIFICATION FOR THE TURNKEY, DESIGN AND BUILD OF THE OPERATIONS & MAINTENANCE (O&M) BUILDINGS

Table Related Arlington County Standards, Specification and Policies

Appendix J - Custom Uniformat for EDU Migration

CITY OF ANDERSON BUILDING AND CODES 601 South Main Street

SPECIFICATION OUTLINE. 28 November 2017 REV 2

Design Aid for Barrier-Free Accessibility in Existing Buildings

Property Offering. Cold Storage Warehouse 4501 Hitch Peters Road Evansville, IN 47711

FIELDS OF NANTERRE. c/o Omega Management, Inc th Avenue North #108 Plymouth, MN MAINTENANCE SERVICE POLICY

JV PROPERTIES, LLC (AQUA GLASS/MASCO) 320 INDUSTRIAL ROAD ADAMSVILLE, MCNAIRY COUNTY, TN Approximately 511,807 square feet

Appendix A. Stormwater Pollutant Sources/Source Controls Checklist

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

Contact Clark Public Utilities Construction Services department at (360) to initiate a request for service.

FACILITY COMPONENTS - ELEMENTARY SCHOOL

Natural Gas Service Installation and Meter Clearance Requirements

O U T L I N E S P E C I F I C A T I O N S

ST. CLOUD, MN 316,000 Square Feet Situated on Acres

Fences, Wall and Hedge Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Quad/Graphics 295,000 Square Feet on Acres Dickson, Tennessee

UCC Permit Application Procedures

Agenda Item 4 Southeast Corner Everett and Waukegan Roads Waterway Car Wash, Gas and Convenience Store

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

NEW ILLUMINATED LED SIGNAGE PAINTED STOREFRONT W/ VINYL GRAPHIC AND NEW LED SIGNAGE PAINT FINISHES (PROVIDE (2) COATS FOR ALL PAINTING) PT-1

FACILITY COMPONENTS - ELEMENTARY SCHOOL

G703 Continuation Sheet Minimum Schedule of Values Please use the breakdown listed below when submitting your billing for the project

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents

RESIDENTIAL DESIGN GUIDELINES FOR BENT TREE OF ROGERS

Facilities Feasibility Study Laurence G. Paquin Building Condition Assessment

Facility Assessment Report, Montgomery Independent School District

Unity Office Building 400 Unity Street Latrobe, PA 15650

HURON PUBLIC WORKS BUILDING HURON, SOUTH DAKOTA BID NO R

Borough of Doylestown Building and Zoning Department

Current as of 11/10/08 1 of 5

City of East Lansing Marriott Parking Structure

ST. CLOUD, MN. 316,000 Square Feet Situated on Acres. For additional information contact:

SECTION 11 Architectural and Nonstructural Elements Field Investigation

Public and Institutional Development

STREET LIGHTING GENERAL INFORMATION

.2 These guidelines should be read with the specific technical sections of McGill s Building Design and Technical Standards.

SECTION 3200 CONCRETE CURB AND GUTTER

Corridor Residential Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Administrative Offices

SECTION ALTERNATES

Transcription:

DIVISION 13 00 40 PARKING STRUCTURES 1. Design Requirements 1.1. A parking design professional must be used to provide the functional and structural design of the facility. 1.2. A traffic analysis is required to determine the ingress/egress design. 2. Architectural Requirements 2.1. The architectural design must be security and maintenance friendly. Passive security design must be considered wherever possible. The design must avoid creating any hiding places. The use of glass as a design element is recommended to promote security. 2.2. The entire perimeter of the ground level must be fenced to restrict pedestrian access to designated entry points. 2.3 All vertical and overhead concrete surfaces in parking facilities must be primed and painted with eggshell white latex paint. Dulux Spraymaster Pro Uni-Grip WB Dryfall Aquacryllic 1482-1200 is the approved paint. 2.4. An exterior clock with lighted hands and numerals must be included in the design. 3. Functional Requirements 3.1. A clear-span design must be used for parking facilities. Parking bays shall be between 54 feet and 57 feet wide with 60 degree to 65 degree parking stalls that are 8 feet, 6 inches wide. Design a one-way traffic pattern. 3.2. A minimum clearance of 8 feet, 2 inches is required on the ground level. A minimum clearance of 7 feet is required on all other levels. 3.3. Ingress and egress lanes shall be placed together and in such a way that the facilities can be loaded and unloaded from an end location. 3.4. All parking equipment, including attendant booths, gates, ticket dispensers and card readers shall be placed on concrete islands. 3.5. Six-inch steel bollards that are filled with concrete shall protect all attendant

booths, parking equipment, tension cables and deck edges from vehicular damage in all parking areas. 3.7. All vertical pipes shall be protected by 1/4-inch by 12-inch steel guards that are mounted at mid-bumper height. 4. Structural Requirements 4.1. Parking facilities shall be post-tensioned, cast-in-place concrete structures. 4.2. All rebar above top of footing or caisson shall be epoxy-coated. The concrete mix for all post-tensioned slabs and beams and columns shall meet minimum requirements as follows: Compressive Strength at 28 days: 7000 psi Cement: 658 Lbs. Microsilica (Condensed silica fume-dry densified powder form): 5% by weight of cement with 4 gallons DCI calcium nitrite corrosion inhibitor per cy. 4.3. A 2-inch concrete cover over reinforcing steel is required. 4.4. A medium broom finish shall be used in all parking areas. 4.5. Silicone caulk is required for all control joints. 4.6. A waterproof deck coating membrane must be applied to all deck areas on top of finished spaces. 5. Parking Operations Requirements 5.1. Each parking structure shall operate as a mixed-use facility, meaning it shall accommodate both public and contract (monthly) parking. Therefore, each entry and exit lane shall include both card access and public parking equipment, including the capability to pay by credit card. 5.2. Proprietary Amano-McGann hardware and software shall be used for: A. The contract parking card access system B. Public parking equipment, including ticket dispensers and gates, revenue control and facility counting 5.3. Proprietary Park-hut protocols shall be used for parking attendant booths. 5.4. An employee only bathroom near the attendant booth is required.

6. CCTV Security System Requirements: An integrated emergency communications/cctv system is required for all stairwell landings, elevator lobbies, vehicle/pedestrian access points and attendant booths. Refer to Division 28 Electronic Safety and Security for system design and equipment requirements. 7. Communications: Campus phones shall be installed on the ground floor of every elevator lobby and in each parking attendant booth. A local call telephone shall be installed in the primary attendant booth, and campus only phones shall be installed in the secondary booths. 8. Maintenance Requirements 8.1. Maintenance Rooms: A 1,000 square foot room shall be located on the lower level (typically at the crossover) for storing a power sweeper and skid loader. A 14-foot by 7.5-foot overhead door shall be provided for access. A pedestrian door also shall be provided. 8.2. A 650 square foot, walled area with a concrete floor shall be provided for a dumpster and for sweeping debris. The area must be located immediately inside the exterior of the building with direct access from the facility and street. 8.3. Custodial closets are required in elevator and stairway lobby banks. Closets shall include a source for hot and cold water, as well as a floor sink. Multiple custodial closets are required at large facilities. 8.4. To facilitate deck washing, a water source that uses 1-1/2 inch NPT connections must be provided. The connections shall be located on every level (no more than 150 apart) to facilitate wash-downs with 75-foot hoses. 8.5. Adequate design considerations must be made to facilitate snow removal at multi-leveled facilities. A. A snow dump area that is approximately 1,000 square feet must be provided at one end of the facility. The surface must be concrete and connect to the storm sewer system. The storm catch basin must have a sediment trap. B. The snow dumping area on the top level of a facility must be devoid of decorative masonry/cap stones or adequate protection must be provided to protect from plowing equipment damage. C. All "outside" masonry corners adjacent to exterior sidewalks or driveways must be protected by a 3/8-inch steel corner to protect from plowing equipment damage.

8.6. All slab on grade floor drain installations must incorporate two-way clean-out fittings installed at a maximum distance of 50-feet between fittings. 8.7 A minimum of 7-foot sidewalk clearance must be maintained around lighting or sign poles to facilitate snow removal. 8.8 All elevator lobby floors should be tiled or equivalent. Safety glass panels in all lobby and stairwell access doors. No sheetrock in stairwells. 9. Electrical Requirements 9.1. Lighting requirements for ceiling mounted fixtures in parking areas: A. Two fixtures are required per bay mounted 18 feet out from each wall (approximately above the rear bumper of a parked vehicle). B. The TEKDEK LED fixture by Kenall incorporating the LimeLight lighting control system by TwistHDM is the required lighting protocol. C. Twenty percent of the light fixtures require power from the emergency generator for emergency lighting if power fails. 9.2. Lighting requirements for top deck fixtures and wall pack installations: A. THE EDGE LED fixtures by Cree incorporating the LimeLight lighting control system by TwistHDM is the required lighting protocol. B. Twenty percent of the light fixtures require power from the emergency generator for emergency lighting if power fails. C. Top deck light poles shall be hinged or otherwise capable of being safely lowered to maintain the fixtures. 9.4. Provide easily accessible photocell control for exterior lighting on all levels at grade or above. 9.5. Electrical conduits shall be surface-mounted (not placed within any cast concrete). 9.6. An emergency power generator is required for any structured facility. It shall be sized to provide power for all parking and CCTV security equipment. It also shall provide minimal lighting for pedestrian and parking areas. 9.7. Receptacles shall be provided on the main landings of all stairwells and in all elevator lobbies.

9.8. The University of Minnesota requires separate rooms for high voltage equipment, medium voltage equipment and telecommunications. 9.9 LED or other energy efficient illumination sources should be used in all directional or facility identification signs, emergency exit designations, elevator cab lighting or in any other applicable use. 10. Mechanical Requirements 11. Elevators 10.1. All attendant booths must include a powered ventilation system to provide positive booth pressure using outside fresh air. 10.2. Facility ventilation shall be controlled by carbon monoxide detection. 11.1. Elevator walls and doors shall be finished in stainless steel. 11.2. Glass shall be installed on the back panels of elevators if they face outside walls. 11.3. Emergency power for one elevator must be provided. In fire mode, every elevator must go to the ground floor and shut off with the car doors in the open position. 11.4. Elevator equipment shall include floor indicators on every level. A. Lighted indicators with up and down arrows shall be included inside and outside of elevator cars. The indicators designate which direction the cars are going. Lighted indicators with floor numbers also shall be included inside and outside of the cars. B. Provide the designated color codes for each floor in the elevator cars. Contact Parking and Transportation Services for complete swatch samples. 11.5. Each elevator shall have a dedicated phone connection to BSAC, and must include caller identification of the facility name and the car number. 11.6. Security cameras integrated into the overall facility security system will be mounted in each elevator. 12. Signage: All interior and exterior signs must be designed to existing protocols as a

system-wide integration as established in the Division 130063 Parking Signage and Graphics Standards for parking specific signage and Division 130061 University Signage and Graphic Standards (general signage) or Division 130062 Duluth Signage and Graphic Standards (general signage). Required signage includes exterior facility designation and space information, alpha-numeric signs designating parking bays, vehicular and pedestrian way-finding signs. 13. Striping Requirements: Unless otherwise noted, all parking stall striping along with any interior curbing must be painted using yellow paint. 14. Landscaping 14.1. Landscaping design shall consider CPTED recommendations. 14.2. An automatic irrigation system is required for landscaped areas. Refer Division 130050 Landcare Requirements for system design and equipment requirements. 14.3. The A/E shall identify and include sustainable landscaping options to mitigate the effects of storm water from increasing the impervious surface or redeveloping existing surfaces. Sustainable landscaping options include, but are not limited to, catch basins with sediment traps, rain gardens, vegetated swales and sediment ponds. The options must meet all code requirements to provide a means of treating of both volume and pollutant storm runoff from surface lots, while reducing the effects on the storm sewer system. 15. Bicycle Parking 15.1. One (1) bicycle locker with a capacity of two (2) bicycles shall be provided for each 200 ramp parking spaces. Parking and Transportation Services will select installation locations and locker model. End Division 13 00 40 Parking Structures