Smart Energy & Power Quality Solutions Janitza Energiemesstechnik und Energiemanagement Fachkonferenz Energieeffizienz in der Industrie Mexico Stadt, 11.09.2017 Kilian Eckert, Sales Area Manager
50 years experience in measurement solutions 1961: Foundation of Eugen Janitza GmbH. 1986: Foundation of Janitza electronics GmbH. Janitza Overview: 160 employees Family owned enterprise All products are Made in Germany Partners in more than 60 countries world-wide More than 20x enterprises, listed in the German stock-exchange, are Janitza customers Today Janitza is a world leader in Energy Monitoring Page: 2
Energy Management helps to Increase energy transparency and create benchmarks Reduction of energy consumption Increase power supply reliability and plant safety / fire protection Reduce down time Optimize energy relevant processes Reduce emissions of CO 2 Improve your image as green company by Janitza electronics GmbH, Intro, 25. September 2012 Page: 3 Seite: 3
Solutions for EMS technology Complete Solutions for Energy Management, Power Quality & Ground Fault Monitoring (RCM) Energy Management (ISO 50001) Power Quality Monitoring RCM Monitoring Flexible and scalable system architecture Recording of all media: such as electricity, gas, water, steam,... Solutions for Communication and Software Page: 4 Page: 4
Some References Page: 5
Why measuring? Page: 6
What is the benefit of energy management? If you can t measure it, you can t improve it William Thomson, 1. Baron Kelvin known as Lord Kelvin * 26. June 1824, 17. December 1907 No Energy Efficiency without Energy Transparency Page: 7
Why permanently measuring? Temporary measurements are costly without advantages Real transparency is only achievable with permanent measurements! Energy Management Transparency of energy consumption and load profiles Systematical reduction of energy consumption and cost Cost allocations for departments and sites Calculating of KPIs (e.g. energy per product, energy usage per person, energy usage per m² Reduce CO2 emissions Documentation of targets and achievements Page: 8
Why permanently measuring? Whataboutthe(your) Power Quality? Why monitor PQ parameter? Avoidance of unintended production stops Protection of humans and machinery Reduction of maintenance cost Contributes to risk management and fire protection Quick root cause identification Early warning of potential system failures Avoid supply tripping Unbalance Sag/Swell Frequency fluctuations Flicker Harmonics Transients Page: 9
What/ Wheretomeasure? What and Where to measure? Page: 10
Where to measure? Page: 11
3-in-1 Solutions Energiemanagement ISO 50 001 Ground-fault Measurement RCM Power Quality according EN 50 160 3 Solutions with one Janitza Meter Page: 12
3-in-1 Solutions Improve efficiency Reduce energy costs Energy Monitoring Reduce emissions of CO 2 Improve reliability Reduce downtime Optimize maintenance Improve Safety Timely detection of faults Enhance system and fire protection PQ Monitoring RCM Fault Monitoring Page: 13
Wide Product Range P r i c e MID Energy Meters RS485 UMG 96RM Series with various interfaces UMG 103 Power Analyzer RS485 UMG 508 Power Analyzer Ethernet Prodata2 Ethernet Gateway and Data Logger UMG 509 Power Analyzer Ethernet UMG 104 Power Analyzer RS485 UMG 20CM RS485 20 Channel meter UMG 511 Class A Power Quality Analyzer Ethernet UMG 512 Class A Power Quality Analyzer Ethernet UMG 604 Power Analyzer Ethernet UMG 605 Power Quality Analyzer Ethernet Performance Page: 14
An Integrated EMS/PQ/RCM - Solution IT-Environment Database & driver Server Reporting-Tools Hardware Multifunctional meters Power analyzers Power Quality Monitoring devices Communication Ethernet/Modbus-Gateways Onboard Ethernet Ports Various protocols (Modbus TCP, Modbus RTU, Profibus, Bacnet, M-Bus, SNMP) Software GridVis, Homepage, Energy Portal and Energy Expert Page: 15
Software Solutions Seite: 16 Page: 16
Software Solutions Webserver and APPs onboard! Page: 17
Software Solutions Serverbased EnMS with GridVis-Ultimate Page: 18
Software Solutions Energy Management at Janitza Company-wide Energydata- Monitoring ISO 50001-certified Monitoring from Transformer to Machines All departments included Measurement of all medias Seite: 19 Page: 19
Software Solutions Energy Management at Janitza Office view Seite: 20 Page: 20
Software Solutions Energy Management at Janitza Overview production Seite: 21 Page: 21
Software Solutions Energy Management at Janitza Detailed view on Hall 6: lighting Seite: 22 Page: 22
Conclusion No transparency without Metering Typical energy saving 10-20%, ROI 12 36 months Reduction of CO2 emissions Improve supply reliability Increase the value of your company Improve your company image Energy Efficiency is a competitive advantage Seite: 23 Page: 23
Many thanks for your kind attention Page: 24
Page: 25
Company Information Copyright, responsibility and liability All rights reserved. Duplication may be carried out after expressed written permission of Janitza electronics GmbH only. No liability can be assumed for correctness and completeness. In no case, there is a reliability for damage, which can occur using the retrieved information. Janitza electronics GmbH Vor dem Polstück 6 D-35633 Lahnau Germany Tel. +49 6441 9642-0 Fax: +49 6441 9642-30 info@janitza.de www.janitza.de Page: 26