INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series

Similar documents
WATER FILTRATION EQUIPMENT LWF Series Commercial Water Filters

INDUSTRIAL SEPARATE BED DEIONIZER. FDI Series. High Purity Industrial Packaged System

REVERSE OSMOSIS WATER TREATMENT

Valve Nest Filter with Time Clock Control Installation and Operation Manual

DETAILED EQUIPMENT SPECIFICATION MFS SERIES FILTERS

COMMERCIAL WATER SOFTENER LWTF SERIES

Akiki Engineering Est.

PUR-1241 ADDENDUM NO. 2 INVITATION TO BID GREENSAND FILTER SYSTEM AT ELK RIDGE WATER TREATMENT PLANT

AEE Water Experts. AKIKI Engineering Est. Commercial Sand Filter. Filtration

FILTERS (Dia x Height) 30 x x x x x x x x x x 170.

Commercial Reverse Osmosis System

The Culligan Hi-Flo 50 Series Industrial Water Filter System

Plug & Play. GreensandPlus Systems... Hungerford & Terry. Pre-engineered to last a lifetime.

AD26 Systems for Iron, Manganese, Sulfide and Arsenic Removal

Trident. Package Water Treatment System

World-Class Equipment & Process Expertise HFX Marketing Package INCLUDED DOCUMENTS. For more information visit

PROJ. NO SECTION DOMESTIC WATER SOFTENERS

COMMERCIAL / INDUSTRIAL COOLING TOWER SIDE STREAM FILTER SYSTEMS

Commercial. Softeners Filters Reverse Osmosis

BuildingName The Description of the Project P DOCUMENTS

Iron/Manganese Package Plant Pre-Engineered Ground Water Treatment. Village of Bolivar, NY

Watch Water. ANSI/NSF 61 Certified From. February 2014

SECTION 5 E-Treat Water Conditioning Systems

AERALATER. Packaged Iron and Manganese Removal

Advanced Automation Lowers Labor Cost and Improves Performance at the Las Palmas, California Wastewater Treatment Plant

PROflex* 60 Hz reverse osmosis machines from 50 to 360 gpm (12-82 m 3 /hr) Water Technologies & Solutions fact sheet.

SPECIFICATIONS FOR SANBORN OILY WASTEWATER WASTE MINIMIZATION UNIT MODEL UFV750T

Product Description / Equipment Specifications FlowMAX Reverse Osmosis Products FM Horizontal Pump Series

The Iron Curtain Filtration System

PROflex* 60 Hz Reverse Osmosis Machines from 50 to 360 gpm

Specifications: MoBetta Pro Series Water Store Skid 2600/5200/7800

.1 All equipment, controls and accessories to be compatible with system design, and matched to the steam boiler(s) by the boiler Manufacturer.

Sea Water Reverse Osmosis Container. 1. Description:

Softener and Filters Components and Accessories

Filtration Solutions Industrial & Municipal Products Division

World-Class Equipment & Process Expertise WDI Marketing Package INCLUDED DOCUMENTS. For more information visit

PACKAGE TERTIARY FILTER SYSTEM SPECIFICATIONS MODELS TF-2-39-C THROUGH TF-2-53-C

SPECIFICATIONS - DETAILED PROVISIONS Section Chlorination System (On-site Sodium Hypochlorite Generation System) C O N T E N T S

Seawater Desalination Plant General Specification

Overview. Commercial High-Purity Water Systems and Applications. Quality Water Is Our Business

Cover. Pressure Filters

Cover. Pressure Filters

Odor Control Products

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

DW Module 22 Inorganic Removal Basics Answer Key

Water Treatment & Purification Chemicals

BTT : 1 autoclave bin

SC-Series Commercial Scale Elimination Systems

SUPERSTEAM USG LINE UNFIRED STEAM GENERATOR. Humidification. Sterilization. Pharmaceutical

flow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow

Energy Efficient. & Cost Saving. Continuous Boiler Blowdown Package Heat Recovery Systems. 20 Models from 1,200 pph to 50,000 pph Capacity

Industrial / Municipal

1.1 WORK INCLUDED A. Nortec MLRO Series reverse osmosis water treatment system as indicated on drawing[s] and as indicated on schedule[s].

SERIES L ,000 GPD RO SYSTEMS

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SC Series Modular Reverse Osmosis System. January 2012 Version

Treatment or Process Filtration

EBS Filters. The largest automatic self-cleaning filter for fine filtration. features: up to 7200 m³/h (32000 US gpm) less than 1% of the total flow

FERTILIZER IRRIGATION EQUIPMENT LTD. SERIES 6000 APPLICATIONS

WATER TREATMENT SYSTEMS. Reverse Osmosis, Water Softening, and Dechlorination

High Flow Rate _ WATER SOFTENERS

DESIGN PACKAGE. COMMONS PARK Twin Falls, Idaho

Maintenance of Drip Drip Irrigation Systems. Patrick Byers Regional Horticulture Specialist University of Missouri Extension

Advanced water purifier system operation manual and setup guide

REACTION TANKS ADVANCED MEMBRANE FILTRATION

Astrasand Continuous Backwash Filter. Water Technologies

Duplex _ WATER SOFTENERS

SECTION FIELD PANELS

ADVANCED SOFTENING MATERIAL. for problem water. SIMPLE SOLUTION FOR 5 PROBLEMS hardness iron manganese natural organic matter ammonium

Fiberglass Cooling Towers

Cl500/Cl1000 BROCHURE

U. S. Army Corps of Engineers Liquid Phase Carbon Adsorption Checklist

Project Name: Melut Basin Oil Development. Client Name: PDOC, Petrolium. Development Oman Company. EPC: Dodsal. Consultant: Mott MacDonald

Distributed by: Phone: , Toll-Free U.S. Fax: , Toll-Free U.S.

the faculty for factory program (FFF), Jordan

EMERGENCY WATER. Immediate delivery when emergency response for water and/or waste water is required

Energy and Water Savings

Pilot Study Report. Z-92 Uranium Treatment Process

Filox Backwashing Filters with CK10 Valves and Vortech Tanks

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

Compressible Media Filter (Schreiber Fuzzy Filter)

Waste Water Treatment Equipment

Government Center Water Treatment Plant Kamphaeng Phet Province, Thailand

SECTION PACKAGE BOOSTER PUMP STATIONS

SECTION HVAC WATER TREATMENT

STAINLESS STEEL SHEETS

WATER TREATMENT PLANT BASED ON REVERSE OSMOSIS TECHNOLOGY litres Per Hour

ElectroChemTM Advanced EDR

Filtration Equipment

MASTER. Water Conditioning Corp. OPERATION MANUAL. PURO PRO 1200 SCP Series Modular Reverse Osmosis System. January 2012 Version

Collectors. Water Treatment & Chemical Processing

DIVISION 15- MECHANICAL Section Fire Pumps

POREX Tubular Membrane Filter Modules For Metal Contaminated Wastewater Treatment & Reclamation

MIGHTY THERM CP. Powerful, Efficient, Low Nox. Reliable and. Economical. Gas Fired Commercial Pool Heating Boiler. Heating Systems Company

Leopold Desalination Pretreatment Systems

Commercial Reverse Osmosis Systems and Accessories

Renovation of the Filters at the Soldier Canyon Filter Plant in Fort Collins, Colorado

FLOW REVERSAL DESALINATION TECHNOLOGY

PSP Series Water Purification Systems

50 GPM Skid Mounted Water Purification System

GRS GRS. Model. Groundwater Remediation Systems 1-50 GPM

Transcription:

INDUSTRIAL FILTRATION EQUIPMENT LWS Filter Series (Single, Twin, Triple or Quadruple Demand Systems) 1 P age

filtration equipment can be engineered to solve complex commercial and industrial water treatment problems. Our catalog filtration equipment comes standard with a 2001 electronic cycle controller. Multiple tank systems often utilize the pressure differential package to trigger regeneration. An Optional 3214 Microprocessor provides single, twin, triple or quadruple system capabilities. The controller features single, twin alternating, progressive demand or parallel application options. Multiple tank applications with sequential regeneration and user friendly programming are the premiere features of this controller. Five programmable cycle adjustments are standard for those problem water applications. Optional Allen Bradley PLC control packages come with HMI EZ color touch screen and are extremely user friendly. Lakeside PLC solenoid system features a hold, advance, resume, termination or close of all valves function, for fast, easy field service. The main screen can be programmed to display a variety of parameters such as current flow rates, online tank status and remaining gallons of each vessel. The AB 10/100 IP Ethernet Network Connection port is standard for building management capabilities. Custom Programming and alternate communication protocols are available. Pressure Differential Systems are a frequently requested design for the Multi-Media Systems removing turbidity and suspended particles down to nominal 10 microns. This feature has two pressure connections, one on the inlet pipe and one connected on the outlet pipe. When operator selected or a 10-15 lb. differential in operating pressure occurs, the indicating pressure switch sends a signal to the controller for immediate or delayed regeneration to clean the media bed. The correct backwash duration is critical to prevent premature bed failure. This can be accomplished by observing the backwash water at the end of the cycle and verifying the water is clear, ensuring a clean media bed for peak performance. Carbon Steel Pressure Vessels Standard working pressure options are 100PSI. Higher pressures are available with custom engineered systems. A standard epoxy lining of 10-12 DFT mil is applied internally and 6-8 mils DFT safety blue finish coating applied over the exterior of the vessel. The vessels can be fabricated in non-code or ASME certified. Stainless steel or fiberglass vessels are available. 2 P age

Underdrain The radial hub underdrain uses high quality PVC pipe and fittings, delivering high performance standards. The.010 PVC slotted laterals are installed to utilize the entire bed area minimizing channeling during low flow. This design provides high flow rates, reliability and quality assurance. Lakeside s four point header inlet baffle on 48 and larger vessels increases even flow distribution. Cast Iron diaphragm valve nest design allows each valve to be exactly designed and sized for the required functions, providing the most cost effective, efficient and serviceable system in the market. These valves can be hydraulically or pneumatically operated for your operational requirements. Numerous piping and valve configurations such as Copper, PVC or Stainless steel are available. Boiler drain valves and rack style pressure gauge packages are standard for fast and easy diagnostics. Filter Media Carbon Filtration - Chlorine, chloramine and dissolved organic material removal is accomplished by using a carbon media matched to your application. Contact time and bed depth are very critical in the adsorption process and has a direct impact on the effectiveness of the equipment. To achieve the proper contact time, correct equipment sizing and an outlet flow control is critical. The water supply should be tested with complete water analysis for proper application and engineering. Elevated concentrations of oil, turbidity or iron can foul and prevent optimal performance of the equipment. Pretreatment equipment would be a recommended solution. Greensand Filtration - Iron, manganese and hydrogen sulfide problems require the ph between the 6.8-8.0 ranges for optimum filtration. The manganese greensand media has an oxide coating that oxidizes the iron, manganese and hydrogen sulfide and precipitates on contact. The precipitates are filtered down to nominal 30 microns by the media bed and then expelled during the regeneration process. The media can be regenerated using a continuous feed of chlorine or potassium permanganate or both. The correct backwash duration is critical to prevent premature bed failure. This can be accomplished by observing the backwash water at the end of the cycle and verifying the water is clear, ensuring a clean media bed. 3 P age

Multi-Media Filtration provides filtration down to nominal 10 microns utilizing quartz sand, garnet and anthracite combinations designed to increase service flow rates per square foot of bed area, compared to traditional sand filtration systems. Restratification of the media layer automatically occurs and is based on their density and particle size, which reduces rinse time and water costs. Operating Parameters Pressure 30-100psi. Temperature range 35F-100F Electrical: 120vac, 60Hz Electrical enclosures rated NEMA 12/4x Drain piping limits: 10ft vertical and discharged to an atmospheric floor drain sized to handle the backwash rate of the system (Max proven length is 25ft). OPTIONS AVAILABLE: Skid mounted, pre-piped, pre-wired for faster and cost effective installations PVC, Copper and Stainless Steel Piping Options Non-code and ASME code vessels with custom linings available Separate source back wash systems Sanitized hot water or steam systems available Chemical injection (pre-treatment) Custom controls, programming, pre-engineered and custom engineered systems available 4 P age

MODEL NO. MEDIA TANK L1 L2 L3 L4 LWS-X-20 20" x 54" 25" x 30" x 69" 57" x 30" x 69" 89" x 30" x 69" 57" x 30" x 69" LWS-X-24 24" x 54" 27" x 36" x 70" 63" x 36" x 70" 99" x 36" x 70" 63" x 36" x 70" LWS-X-30 30" x 60" 34" x 42" x 81" 76" x 42" x 81" 118" x 42" x 81" 76" x 42" x 81" LWS-X-36 36" x 60" 40" x 48" x 89" 88" x 48" x 89" 136" x 48" x 89" 88" x 48" x 89" LWS-X-42 42" x 60" 44" x 54" x 90" 98" x 54" x 90" 152" x 54" x 90" 98" x 54" x 90" LWS-X-48 48" x 60" 52" x 61" x 103" 116" x 61" x 103" 180" x 61" x 103" 116" x 61" x103" LWS-X-54 54" x 60" 58" x 66" x 100" 128" x 66" x 100" 198" x 66" x 100" 128" x 66" x 100" LWS-X-60 60" x 60" 64" x 72" x 102" 140" x 72" x 102" 216" x 72" x 102" 140" x 72" x 102" LWS-X-66 66" x 60" 70" x 79" x 104" 152" x 79" x 104" 234" x 79" x 104" 152" x 79" x 104" LWS-X-72 72" x 60" 76" x 86" x 106" 164" x 86" x 106" 252" x 86" x 106" 164" x 86" x 106" 5 P age

MODEL TANK SIZE (Diameter & height) Designed, Tested and Approved for Shipment LWS Multi-Media Filter Model Specifications IN/OUT BACKWASH SERVICE PEAK BWF RATE (inches) IN /OUT QTY. CU.FT. LWS-ML-20 20 x 54 1 1 20 1 30 5 30 7 LWS-ML-24 24 x 54 1 ¼ 1 ¼ 30 1 45 8 45 10 LWS-ML-30 30 x 54 1 ½ 1 ½ 50 2 65 9 75 16 LWS-ML-36 36 x 60 2 2 70 2 105 9 105 22 LWS-ML-42 42 X 60 2 ½ 2 ½ 95 2 140 12 150 30 LWS-ML-48 48 X 60 2 ½ 2 ½ 120 1 170 6 180 40 LWS-ML-54 54 x 60 3 3 160 2 230 8 240 52 LWS-ML-60 60 x 60 3 3 200 2 260 10 300 63 LWS-ML-66 66 x 60 4 4 235 2 350 15 350 75 LWS-ML-72 72 x 60 4 4 275 3 415 7 415 91 MODEL LWS Manganese Greensand Filter Model Specifications TANK SIZE IN/OUT BACKWASH PIPE IN /OUT SERVIC E PEAK BWF RATE LWS-MG-20 20 x 54 ¾ 1 8 3 3 6 25 6 LWS-MG-24 24 x 54 ¾ 1 ¼ 10 4 17 6 40 9 LWS-MG-30 30 x 54 1 1 ¼ 15 3 25 5 60 14 LWS-MG-36 36 x 60 1 ¼ 2 21 2 35 3 85 22 LWS-MG-42 42 X 60 1 ¼ 2 29 3 48 7 110 30 LWS-MG-48 48 X 60 1 ½ 2 40 2 63 4 140 40 LWS-MG-54 54 x 60 2 2 ½ 55 3 80 5 190 51 LWS-MG-60 60 x 60 2 3 69 3 99 5 235 62 LWS-MG-66 66 x 60 2 ½ 3 90 3 130 7 285 75 LWS-MG-72 72 x 60 2 ½ 4 100 3 141 7 340 90 MODEL TANK SIZE LWS Carbon Filter Model Specifications IN/OUT BACKWASH PIPE IN /OUT SERVIC E PEAK BWF RATE QTY. CU.FT. LWS-AC-20 20 x 54 1 1 8 1 22 5 20 5 LWS-AC-24 24 x 54 1 1 10 1 22 5 30 5 LWS-AC-30 30 x 54 1 ¼ 1 ¼ 15 2 49 9 45 12 LWS-AC-36 36 x 60 1 ½ 1 ½ 21 2 65 9 70 18 LWS-AC-42 42 X 60 1 ½ 2 29 2 96 12 90 24 LWS-AC-48 48 X 60 2 2 40 1 120 6 110 32 LWS-AC-54 54 x 60 2 2 ½ 55 2 159 8 150 40 LWS-AC-60 60 x 60 2 ½ 2 ½ 69 2 175 10 190 50 LWS-AC-66 66 x 60 3 3 90 2 210 15 245 60 LWS-AC-72 72 x 60 3 3 100 3 250 7 270 75 QTY. CU.FT. 6 P age