FIXTURE CARRIERS TABLE OF CONTENTS S-WD-FC

Similar documents
optional parts for geberit Duofix carrier

University of Delaware

ZS880 Linear Shower Drain Installation Instructions

SECTION PLUMBING FIXTURES

MIFAB SAMPLE FIXTURE SCHEDULE & SPECIFICATIONS

Gas Station & C Store SECTION CWM Job No

FLOOR AND AREA DRAINS

The City Of Winnipeg R1. St. Vital Park Pavilion Page 1 of 9

SPECIFICATION DRAINAGE PRODUCTS

MATHIS WALL-MOUNT FAUCET

200 Series In-Slab Pool Fittings

SECTION PLUMBING FIXTURES

DRAINS: & , S COMMERCIAL. Drains: Bath, Shower & Commercial

Technology. Enabling Design. Geberit Duofix Carrier

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

PC-PH SERIES BTUH

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION PLUMBING SPECIALTIES

Inigo Console Table INSTALLATION INSTRUCTIONS P74300, P A Page 1 of 5

PC-PH SERIES 2 TON. Installation Instructions

1.04 SUBMITTALS PLUMBING FIXTURES

SECTION DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

THE INSTALLING INSTRUCTION FOR CONCEALED TANK

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

GB-75. High Efficiency Grease Interceptor Technical Data. Submittal Specifications Installation Application Specific Details

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Installation Manual. Modular Bar Die. Krowne Metal Corporation 100 Haul Rd. Wayne, NJ Toll Free: (800) Fax: (973)

A. Codes and Standards that are Standards at the University. A. Provide floor drains in all toilet rooms, janitor closets, and mechanical rooms.

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

SECTION PLUMBING EQUIPMENT AND SPECIALTIES

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

t y p e V S A S E W A G E P U M P

October 4, 2013 Construction Set OR RENOVATIONS BID PACKAGE 2 SECTION PLUMBING

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DRAINS AND CLEANOUTS. 1. Division 7 - Thermal and Moisture Protection Piping (Plumbing).

DESCRIPTION SAFETY: WARNINGS ORDERING INFORMATION T01-B INSTALLATION INSTRUCTIONS DROP-IN AND FREESTANDING BATH K-11343T / K-11344T

Smarter. Safer. Leaner.

Terrain HDPE. Product Guide

GB-75. Submittal Specifications Installation Application Specific Details

RYLE THERMOSTATIC SHOWER SET INSTALLATION

FORMWORK 66 x 40 x 24 Lithic Freestanding or Alcove Box Bathtub Installation Guidelines. STYLE No. CAUTION: BATHTUB IS EXTREMELY HEAVY

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

GB-20. Submittal Specifications Installation Application Specific Details

Arms Group Drainage System. 1. Swivel Joint Type 2. Pivot Joint Type 3. Flexible Hose Type 4. Swing Master Joint Type 5. Floating Check Valve

C.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions

SECTION NON-STRUCTURAL METAL FRAMING

Wall-mounted systems. By SCHELL. For professional sanitary rooms.

INDEX General Information Flush Frames Drywall Frames Technical Data Sheets Anchors

SECTION Manufactured Metal Casework FLEXIBLE LABORATORY FURNITURE SYSTEM (OPTIMA) USA VERSION

Metal Framing Engineering Data & Specifications

EXIRA EXPOSED PIPE SHOWER INSTALLATION

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

A. Codes and Standards that are standard at the University. C. Coordinate cleanout locations with Architect.

SECTION VIBRATION ISOLATION

In-Wall Tank and Bowl Carrier System With Dual Flush Technology Geberit Model No Flush Volume: 1.6 / 0.8 GPF / 3.

Porcher Solutions Wall Mount, Pedestal and Above Counter Lavatories

Technology in bathrooms

Fig Beam Clamp Retaining Strap (B-Line B3367)

Invisi II Dual Flush/Single Flush Inwall/Under Counter/Induct/Inceiling Cistern. CI/SfB (74.4) n6 Date October 2014

1. Section "Residential Plumbing Fixtures" for residential sinks.

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

OVERSHOT GATE TECHNICAL DATA SHEET

FreeStyle Linear Drain with Full Mortar Bed Adapter Kit

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT. A. ASME B31.1 (American Society of Mechanical Engineers) - Power Piping

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Winged steel blade stanchions supporting glass panels

PrivaSEE All Glass Single Track Sliding System for Acoustical Separation

SECTION PLUMBING FIXTURES. A. This specification describes the requirements for plumbing fixtures and their installation.

C. Concrete Inertia Bases: Drawings showing required concrete steel reinforcing, construction details, and dimensions.

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

Invisi II. 242 For further information visit or call The more stars the more water efficient WATER RATING

BUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor

ROOF DRAINS TABLE OF CONTENTS

4400 Series UPS Seismic Adapter Kit Installation Instructions

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

Trench Duct Class Catalog 5230CT9601R10/08

D. Encase exterior cleanouts in concrete with access cover installed flush with grade.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING. A. This Section includes the following storm drainage piping specialties:

A. Provide floor drains in all restrooms placed a minimum of 7 from back of wet wall, janitor closets, and mechanical rooms.

.1 ANSI/ASME B31.1, Power Piping, (SI Edition)..2 American Society for Testing and Materials (ASTM)

PRE-INSTALLATION GUIDE

Infinity - Century Combination Installation Instructions Gelcoat & Solid Surface Bathware

Element D Services Plumbing

TFX - Toggle Lock Installation Guide

1.2 ACTION AND INFORMATIONAL SUBMITTALS.1 Provide submittals in accordance with Section Submittal Procedures.

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

Installation Manual For Conical Tanks. INSTALLATION and MAINTENANCE INSTRUCTIONS FOR CONICAL TANKS

Interior Hangers. Application

CONTINUED ON FOLLOWING PAGE

TILT-UP LIFTING PRODUCTS

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Steel Forming System BROCHURE. A durable, all-steel forming system that is ideal for pier caps and self-spanning applications.

Copyright 2017, ProVent Systems Inc., All Rights Reserved

SECTION PLUMBING PIPING SYSTEMS

.2 Section Waste Management and Disposal

ROOF MOUNT KIT OWNERS MANUAL

Box Rail. Single Box Rail Bracket

INSTALLATION MANUAL RECTANGULAR COLUMN

Transcription:

TABLE OF CONTENTS Pictorial Index Product Recommendations Water Closet Carriers Matching Water Closet & Carrier Closet Carrier Selection & Battery Set-Up Stud & Nipple Adjustment to Finished Wall Anchoring Carrier to Floor Thin-Wall Carrier Set-Up Commonly Specified Options Typical Installations Wall Hung Fixture Carriers Lavatory Carriers Urinal & Water Cooler Carriers Service Sink Carriers Typical Installations S-WD-FC-1 0812

PICTORIAL INDEX ISCA-101-L/R Industry Standard Horizontal Water Closet ISCA-121-D Industry Standard Back-To- Back Vertical Water Closet ISCA-560-4 Service Sink ISCA-151-D Back-To-Back Offset Thin Wall Vertical Water Closet ISCA-101-L/R-AUX Industry Standard Horizontal Water Closet w/aux Inlet ISCA-131 Industry Standard Vertical Water Closet w/side Inlet ISCA-141 Thin Wall Vertical Water Closet CA-311 Urinal ISCA-101-D Industry Standard Back-To- Back Horizontal Water Closet ISCA-131-D Industry Standard Back-To-Back Vertical Water Closet w/side Inlet ISCA-141-4-D Back-To-Back Thin Wall Vertical Water Closet CA-321 Urinal w/bearing Plate ISCA-121 Industry Standard Vertical Water Closet ISCA-550-4 Service Sink ISCA-151-L/R Offset Thin Wall Vertical Water Closet CA-401 Exposed Arm Lavatory S-WD-FC-2 0812

PICTORIAL INDEX Photo not available at this time CA-401-D Exposed Arm Lavatory CA-462 Wall Mounted Concealed Arm Lavator TCA-411-WC 27 x 20 Concealed Arm Lavatory CA-421 Water Cooler CA-481 Wall Plate Lavatory TCA-411-D-WC Back-to-Back 27 x 20 Concealed Arm Lavatory CA-431-1 Hi-Lo Water Cooler TCA-411 Concealed Arm Lavatory CA-461 Wall Mounted Concealed Arm Lavatory w/back Plate S-WD-FC-3 0812 TCA-411-D Back-to-Back Concealed Arm Lavatory

PRODUCT RECOMMENDATIONS Application Product Wall Hung Closet - Standard Commercial... ISCA-101-L/R, ISCA-101-D, ISCA-121, Construction & Batteries... ISCA-121-D, ISCA-131-L/R, ISCA-131-D Wall Hung Closet/Urinal Back-to -Back... ISCA-101-L/R-AUX Wall Hung Closet - Thin Wall Construction... ISCA-141, ISCA-151 Urinals... CA-311, CA-321 Lavatories - Exposed Arm... CA-401 Lavatories - Concealed Arm... TCA-411, TCA-411-D, WCA-411, WCA-411-D Lavatories - 27x20 Concealed Arm... TCA-411-WC, TCA-411-D-WC, WCA-411-WC, WCA-411-D-WC Water Coolers, Drinking Fountains... CA-421, CA-431-1 Service Sinks... ISCA-550, ISCA-560 INDUSTRY STANDARD WATER CLOSET CARRIERS Watts Industry Standard Water Closet Carriers support wall hung "off the floor" water closets, independent of the wall structure. Water closet carriers anchor to the floor behind the finished wall, effectively transferring the load from closet to the structural floor. Watts patent pending Industry Standard Carriers incorporate a trusted compression sealing mechanism that replaces leak prone threaded and o-ring seals. Behind the wall leaks can cause significant damage, and trigger mold formation problems. Industry Standard Carriers adjust easily with a standard socket extension, and hold test first time, eliminating expensive leak plugging and re-test procedures. S-WD-FC-4 0812

Matching Water Closet & Carrier WATER CLOSET CARRIERS Wall hung water closets are mounted with either 4-bolt (siphon jet) or 3-bolt (blow-out) patterns. Watts ISCA-101, ISCA-121, & ISCA-131 Series carriers will accommodate either siphon jet or blow-out wall hung bowls. Faceplates are supplied in the siphon jet (4-bolt) position, but may be inverted and re-configured at the jobsite to mount blow-out (3-bolt) bowls. ISCA-141 & ISCA-151 thin wall carriers are for installation only with 4-bolt siphon jet bowls. All commercial wall hung bowls have similar bolt patterns, and can be accommodated with any standard Watts closet carrier. 9 9 7 1/2 JCA 100 PFP WATTS 6 1/4 JCA 100 PFP WATTS 4 BOLT SIPHON JET ARRANGEMENT 3 BOLT BLOWOUT ARRANGEMENT 4 BOLT SIPHON JET ARRANGEMENT 3 BOLT BLOWOUT ARRANGEMENT Siphon Jet Blowout Closet Carrier Selection & Battery Set-Up (ISCA-101, ISCA-121, ISCA-131 Series) Closet carriers are often installed in groups (batteries) to accommodate multiple fixture, or back-to-back bathroom groups. These factors should be considered in the specification and construction of ISCA-101/ISCA-121/ISCA-131 Series batteries: 1.) Location of the Waste Stack The waste stack may be located directly behind a water closet, or a midpoint or end of the closet battery. Position of the stack will determine the type of carriers required, as all waste flows towards the stack. 2.) Horizontal Carrier Direction Horizontal carriers are specified either left hand or right hand (L or R). With your back to the wall (sitting on the bowl), point in the direction of flow. If the flow is to the left, a left hand carrier is required (ISCA-101-L). Back-to-back carriers are reversible, and do not require a flow direction specification. WASTE WASTE STACK DIRECTION DIRECTION OF OF FLOW DIRECTION OF FLOW WATTS ISCA-101-L CA 101 L HORIZONTAL LEFT-HAND LEFT HAND S-WD-FC-5 0812 Horizontal Direction WATTS CA 101 L ISCA-101-R HORIZONTAL RIGHT HAND RIGHT-HAND

WATER CLOSET CARRIERS 3.) Vertical Carriers with Side Inlets (Stack Fittings) ISCA-131 Series carriers are specified in batteries with a waste stack located directly behind one of the bowls. The inlet direction (L or R) is determined by pointing in the direction of flow while facing the wall. If the flow comes in from the right, a right hand inlet is required (ISCA-131-R). For stack carriers receiving flow from both directions, specify dual side inlets. Back-to-back carriers are reversible, and do not require a flow direction specification. 36" 36" 36" 36" WATTS ISCA 101 L HORIZONTAL LEFT-HAND FITTING WATTS ISCA 131 VERTICAL FITTING WITH 2 SIDE INLETS WATTS ISCA 101 R HORIZONTAL RIGHT-HAND FITTING 4.) Battery Pitch & Rough-In Requirements* Standard bowl installations are 15" from floor to rim of the bowl, and "Physically Handicapped" (ANSI A-112.19.2) installations 18" to the rim of the bowl. Assuming standard rough-in specifications of 1/8" pitch on the horizontal waste line, and 36" between fixtures, batteries may be constructed with up to 10 fixtures, provided a stack fitting (see ISCA-131 Series) is used in one of the center positions (fig. 1). Handicapped fixtures can be incorporated into batteries, and should be placed at the high end of the fixture run. The table below indicates minimum and maximum horizontal waste line positions, dependent upon the specified rough-in height for the bowl outlet. *Siphon jet closet installations only - consult factory for blowout closet batteries Figure 1 C/L Bowl Outlet Min. C/L Horiz. Max. C/L Horiz. From Floor Waste from Floor Waste from Floor 4-1/2" 3" 4-1/2" 5" 3" 5" 5-1/2" 3" 5-1/2" 6" 3" 6" 6-1/2" 3-1/4" 6-1/2" 7" 3-5/8" 7" 7-1/2" 4-1/8" 7-1/2" 8" 4-5/8" 8" 8-1/2" 5" 8-1/2" 9" 5-3/8" 9" 9-3/8" 5-3/4" 9-3/8" 36" 36" 36" 36" 2 7/8 5 1/4 5 1/4 5 1/4 3 1/4 3 5/8 5 1/4 4 8 1/4 4 3/4 S-WD-FC-6 0812 WATTS ISCA-131 VERTICAL CARRIER WATTS ISCA-101-R HORIZONTAL RIGHT-HAND CARRIER WATTS ISCA-101-R HORIZONTAL RIGHT-HAND CARRIER WATTS ISCA-101-R HORIZONTAL RIGHT-HAND CARRIER WATTS ISCA-101-R HANDICAPPED POSITION HORIZONTAL RIGHT-HAND CARRIER

WATER CLOSET CARRIERS Stud & Nipple Adjustment to Finished Wall Closet horn depths and flange thicknesses may vary slightly, dependent upon the manufacturer of the fixture. The closet nipple is usually set 5/16" beyond the face of the finished wall, allowing for sufficient closet gasket compression, which ensures a gas and water tight seal (fig. 2). Fixture studs generally extend 2-1/4" beyond the finished wall, with the back-up nut set flush with the wall, and a 1/16" back-up washer between the wall and the fixture. Cap nuts must tighten fully to properly load the carrier (fig. 3). These formulas may be used to calculate exact nipple and stud positions: Nipple Position: A = B - 7/16" Stud Position: X = Y + 5/8" Where: A = Distance nipple should extend beyond finished wall B = Depth of closet horn Where: X = Distance stud should extend beyond finished wall Y = Thickness of fixture flange Closet CLOSET HORN Horn B A 1/16" CLEARANCE Clearance BETWEEN BACK Between OF CLOSET & Back FINISHED of WALL Closet & Finished W Finished Wall X Y 1/16" FINISHED WALL SUPPORTING STUD FITTING Gasket GASKET CARRIER Carrier NIPPLE Nipple FIGURE 2 FIGURE 3 Stud/Nipple Adj. Anchoring Carrier To Floor BEARING NUT & WASHER BACK-UP NUT & WASHER Closet carriers must be securely anchored to the structural floor with min. 1/2" dia. lag bolts (supplied by others). Watts unique dual slot foot design speeds anchoring, eliminating the problem of lag bolts conflicting with concrete support bars. S-WD-FC-7 0812

WATER CLOSET CARRIERS Thin Wall Carrier Set-Up (ISCA-141, ISCA-151 Series) ISCA-141 & ISCA-151 Series vertical carriers are specified in single or multiple story buildings with thin pipe chases. The ISCA-141 Series vents directly off the top of the waste stack, and is generally used in single story installations. ISCA-151 Series carriers are commonly specified in multi-story and retrofit applications. An offset waste fitting facilitates installation with absolute minimum pipe space allowances. See fig. 4 for minimum pipe space requirements. 9-3/8" 8-1/8" 9-5/8" 8-1/8" 3-7/16" 4-1/16" Thin Wall Carrier ISCA-141-D SHOWN ISCA-141-4 SHOWN Commonly Specified Options Auxiliary Support System (CA-100-EXT) - Additional support at the finished wall for wide pipe chases. Should be used when 'X' dimension exceeds 18". Supplied with extended coupling (specify length). Extended Coupling (-M1) - Longer coupling to accommodate wide pipe chases. Supplied 24" standard, field cut to suit application. Tiling Frame (-M11) - Creates flat, even surface at finished wall for tile application. Aluminum construction supplied standard. Rear Anchor Support (-M12) - Attaches to back of single carrier fitting, increases carrier strength & stability. Flush Valve Support (-M20) - Supports and aligns exposed flush valve supply pipe. Long Barrel Horizontal (-M36) - For ISCA-101 Series, 36" fitting barrel for quick battery set up. Supplied standard with welded barrel extension. 5/8" 9" CA-100-EXT AUXILIARY SUPPORT 7-1/2" EXTENDED NIPPLE TILING FRAME S-WD-FC-8 0812 CA-100-EXT Tiling Frame

WATER CLOSET CARRIERS 3 11/16 4 1/2" CAST LUG 12" 5/16 5/16 THREADED STUD ANCHOR BOLT (BY OTHERS ANCHOR BOLT (BY OTHERS) ANCHOR FOOT -M12 REAR ANCHOR SUPPORT M12 REAR ANCHOR SUPPORT Anchor Foot Flush Valve Support TYPICAL WATER CLOSET CARRIER INSTALLATIONS 13 3/32" 11 11/16 11/12" 2 11/16" 4 1/4" MIN. MIN. 1/2" 1/2" LAG BOLT REAR REAR ANCHOR SUPPORT 1/2" DIA ANCHOR REAR ANCHOR FOOT ISCA-121 ISCA-141-4 S-WD-FC-9 0812

WALL HUNG Watts wall hung fixture carriers provide structural support for off-the-floor lavatories, urinals, water coolers, and service sinks. Floor mounted carriers work independently of the finished wall structure, and are generally specified in commercial applications. Wall mounted carriers attach to the structural wall, and are typically used with block wall construction, or in light duty or residential applications. Lavatory Carriers A carrier should be used for installation of all wall hung lavatories. Lavatories attached to the wall with only a fixture mounting bracket will eventually become unstable, causing damage to the wall, and creating a potentially hazardous condition. Lavatories are commonly designed for installation with concealed arm carriers, whose supporting arms extend through cavities in the back of the fixture. A concealed arm carrier is entirely hidden by the lavatory and the wall, providing support without aesthetic degradation. Exposed arm carriers are designed with L-shaped support brackets, which extend from the carrier, and bolt to the underside of the fixture. Plate type carriers bolt directly to the fixture mounting bracket. As there is minimal cantilever strength, plate carriers provide somewhat less support than concealed or exposed arm carriers. Urinal & Water Cooler Carriers Urinal and water cooler carriers use support plates, which bolt directly to fixture mounting bracket(s), transferring the fixture load to the structural floor. These carriers are entirely concealed by the fixture and the wall. Service Sink Carriers Service sink carriers are commonly used in clinical applications, to support surgical scrub or flushing rim sinks. Similar in function to water closet carriers, service sink carriers provide structural support, and facilitate waste line connection. TYPICAL WALL HUNG FIXTURE CARRIER INSTALLATIONS TILE SLIDE FOR VERTICAL ADJUSTMENT SLIDE FOR VERTICAL ADJUSTMENT CA-321 MIN. 1/2" ANCHOR BOLTS (BY OTHERS) CONCRETE FLOOR S-WD-FC-10 0812

TYPICAL WALL HUNG FIXTURE CARRIER INSTALLATIONS UPRIGHT CLAMP FOR VERTICAL ADJUSTMENT CROSSPLATE LEVELING SCREWS CONCEALED ARM LOCKING DEVICE ARM BRACKET FOR HORIZONTAL ADJUSTMENT LOCKING DEVICE WALL STRUCTURE TILE NUT LOCK NUT LEVELING SCREWS LEVELING SCREWS LEG ASSEMBLY CONCEALED ARM CONCEALED ARM DEVICE LOCKING DEVICE TCA-411 CA-461 2" 3" 14 5/8" 9" 1" MIN 3" MAX 6 1/4" 42" 4" FITTING = 7 5/32" 3" FITTING = 6 13/32" GASKET 1/2" LAG BOLTS (BY OTHERS) ISCA-550-4-V4 3" 4 1/2" S-WD-FC-11 0812