THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

Similar documents
Understanding thermal mass

Chapter 7. Passive Solar Contents

The case for research

Thermal comfort in a 21st century climate

Datasheet. Thermal Benefits of Solid Construction

G R E E N L I V I N G

Report for CSR Hebel. Impact of various wall and floor construction options on 5 star compliance for two houses. by Tony Isaacs Consulting Pty Ltd

&OLPDWH#)#&ORXGV## 6RODU#WKDW#:RUNV#

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES

APR TECHNICAL note. Six-Star Concrete Housing. Six-Star Concrete

Construction Studies Theory - Higher Level

Building Code requirements for house insulation

Table P1: Effective air change rate. Trickle vents only. Windows fully open. Windows slightly open (50 mm) Windows open half the time

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Guidance on U Values from Domestic Heating Design Guide

CEILING TILE. Thermal Mass. Passive Cooling. Thermal Comfort

Poor distribution & glare

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM AND HEAVY MASS BUILDING IN BELGRADE

A COMPARATIVE STUDY OF THE THERMAL PERFORMANCE OF CAVITY AND BRICK VENEER CONSTRUCTION

Designing for Queensland s climate. Designing for Queensland s climate

Solar Home Design and Thermal Mass

ECOLOGY BUILDING SOCIETY HQ Environmental Specification

Construction Studies Theory - Higher Level

3C.1 Passive Solar Design National Sustainable Building Advisor Program

Energy Efficiency Design Guideline for Commercial and Industrial Development

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

Save up to 25% off your energy bills with bricks. Create a low maintenance home for life Live comfortably and in style

Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

NCC Volume Two Energy Efficiency

7. MATERIALS AND TECHNICAL INVESTIGATION

THERMAL PERFORMANCE OF AUSTRALIAN MASONRY HOUSING HEATING/COOLING DEMANDS UNDER SPRING CONDITIONS

THE INFLUENCE OF WALL PROPERTIES ON THE THERMAL PERFORMANCE OF AUSTRALIAN HOUSING

SOLAR GREENHOUSES Calling a greenhouse solar is somewhat redundant, since all greenhouses are solar heated to some extent. The greenhouse itself

TECHNICAL SHEET. The material properties and use of clay brick. Teaser

Thermal Mass Explained

CHAPTER 1 INTRODUCTION

Procedia - Social and Behavioral Sciences 216 ( 2016 )

Passive Solar Energy Primer. Arizona Solar Center. Revised: 2015

Radical POTENTIAL!! COMFORT ZONE WHAT IS IT? WHAT DOES IT HAVE TO DO WITH GREEN BUILDING + ZERO CARBON?

CHAPTER 6 CONCLUSION

ARPAN JOHARI. Architect. 13/08/10 AW Design. Ahmedabad

TIPS FOR ENERGY SAVING IN OLD AND NEW HOMES

Attached Solar Greenhouse Plans for a solar heated greenhouse attached to your home

What you need to know about 6 Star. 6 Star. for new homes, home renovations, alterations, additions and relocations

Insulation Installation

General guidelines for using thermal mass in concrete buildings

Thermal Mass Explained

CB04. Outback House. Case Study. Creative Spaces Australia. by Casey Brown Architecture

Design and retrofitting of a hybrid building in Athens

4. Insulation of external walls

The costs of improving the thermal performance of houses in a cool-temperate climate

PassiveDesign.org. Principles of Passive Design

Passivhaus Project Documentation Wrexham Passivhaus

362: Indoor climate control effect of AAC panels as determined by house model measurements and simulations

Garage Conversions. Technical Issues

Construction Studies Theory - Higher Level

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

CHAPTER 4. Benefits of solar access. Siting for solar access. Diffuse and direct solar radiation

SOLAR PHOTOVOLTAIC ENERGY

Building regulations now in force

SHELTER FOR COMPOSITE CLIMATE

Project name SOLAR HOUSE 80/50 Project summary

Unit 8 Walls & Partition

Energy consumption and thermal comfort in a passive house built in Romania

COPYRIGHTED MATERIAL. Contents. 1 Making Buildings 3. 3 Wood Foundations and. Preface to the Sixth Edition xi. Sitework 31

CASE 1 : SINGLE FAMILY HOUSE. VIA / TCU 3rd semester workshop A2015. Building. Component Technical Course. VIA/ TCU workshop A2015

the windows handbook a guide to energy efficient windows and doors by Capral smart windows HANDBOOK Vol. 1

SMART SOLUTIONS DOUBLE GLAZING SOLAR COMFORT TINTING GLASS ASK OUR SALES REPRESENTATIVES ABOUT. Reduce your 23% energy costs * by as much as

RENDERED WALL SYSTEM. Combining exterior cladding with superior insulation

Annexure A Request to MoEF&CC for issuing Certified Compliance Report

IFORE Retrofitting Works Outreau. Pre-retrofit Description

FirstRate Report HOUSE ENERGY RATING C:\...\WA U Tony Pike - Lic No

Passive Solar Design. Passive solar design 1 New South Wales Technical and Further Education Commission 2014 (TAFE NSW - WSI)

Primary School Retrofit Project

half of the energy transmitted from the sun is in the visible light wavelengths.

CONCRETE PERFORMANCE. Jeff Dyson Head of Housing Solutions. The Concrete Centre

Fundamentals of Building Construction: Materials and Methods

Construction Studies Theory - Higher Level

Responsive Building Elements Actual Development and Trends Within IEA

carbon-neutral architectural design Pablo La Roche CRC Press Taylor & Francis Croup Boca Raton London NewYork CRC Press is an imprint of the

residential Passive Design for temperate climates

PCM s in application for acclimatization of buildings. Nick Barnard, Faber Maunsell VSK2008, Workshop on heat storage

house hot humid BLAKELY RESIDENCE THE BRIEF

Guidelines. Checklist for Building Approval. 1. The Site

Refusal to issue a building consent for a house with insulated concrete walls at 11 York Road, Riversdale, Southland

Building Construction 7. Dr Nabil El-Sawalhi Associate professor Engineering Projects Management

European Timber Windows & Doors

Advanced Design and Building Information Modeling February. Would you like to develop a BIM model of this project? no

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

William Stanwix and Alex Sparrow. The. Hempcrete. Book Designing and building with hemp-lime. sample pages to show book layout and design only

Contact Details: Phone Fax . Work Description: New Building Extensions Refurbishment Change of Use. Yes No Method:

Stage 6 & 7 Design Guidelines

EXTERNAL SHADING DEVICES

Multi-layer Insulation Blanket for Walls

Chapter 2 Literature Review

Definition of Wall. A continuous, vertical structure Thin relatively to its length and height

Project Description. Projected build start date 03 May 2010 Projected date of occupation 06 Aug

THERMAL INSULATION FROM WOOD FOR BUILDINGS:

ASHRAE Hot Climate. Frank Mills

GLASS SELECTION GUIDE

Transcription:

CHAPTER 6 THERMAL MASS mud brick concrete block brick The contents of this chapter explain the effect of thermal mass and provide guidelines for its location and extent. Summer and winter effects of thermal mass and the relationship with climate are also outlined. concrete slab Figure 6.1: Materials with high thermal storage capacity stud wall timber floor weatherboard cladding Figure 6.2: Materials with low thermal storage capacity heat is absorbed by the slab during the day, reducing internal temperature summer sun Understanding thermal mass Thermal mass is a term used to describe the ability of building materials to store heat (thermal storage capacity). The basic characteristic of materials with thermal mass is their ability to absorb heat, store it, and at a later time release it. Adding thermal mass within the insulated building envelope helps reduce the extremes in temperature experienced inside the home, making the average internal temperature more moderate year-round and the home more comfortable to live in. Building materials that are heavyweight store a lot of heat so are said to have high thermal mass (see figure 6.1). Materials that are lightweight do not store much heat and have low thermal mass (see figure 6.2). The use of heavyweight construction materials with high thermal mass (concrete slab on ground and insulated brick cavity walls) can reduce total heating and cooling energy requirements by up to 25% compared to a home built of lightweight construction materials with a low thermal mass (brick veneer with timber floor). Thermal mass is particularly important for comfort in climates such as northern Victoria, where summer temperatures are high and there is a large difference between daily average maximum and minimum temperatures. Thermal mass is less important, but still beneficial, in climates with lower summer temperatures. However, in situations where solar access is poor, thermal mass could increase winter heating requirements. Seasonal effects of thermal mass SUMMER In summer, thermal mass absorbs heat that enters the building. In hot weather, thermal mass has a lower initial temperature than the surrounding air and acts as a heat sink. By absorbing heat from the atmosphere the internal air temperature is lowered during the day, with the result that comfort is improved without the need for supplementary cooling (see figure 6.3). During the night, the heat is slowly released to passing cool breezes (natural ventilation), or extracted by exhaust fans, or is released back into the room itself. Inside temperatures at night time will be slightly higher than if there was low thermal mass, however with the cooling night effects, temperatures are still within the comfort zone (unless a long spell of consistently hot days and nights is experienced). Figure 6.3: Thermal mass in summer 36 ENERGY SMART HOUSING MANUAL

The ability of thermal mass to even-out fluctuations in indoor temperatures is illustrated in figure 6.4. The solid line represents the air temperature in summer inside a double-brick house with a concrete slab-on-ground floor. The dashed line represents the air temperature inside a lightweight timber building. Note that the temperature variation in the brick house is much smaller and temperatures are almost always within the comfort zone. heat is released by the slab during the day, stabilising internal temperature WINTER In winter, thermal mass in the floor or walls absorbs radiant heat from the sun through north, east and west-facing windows. During the night, the heat is gradually released back into the room as the air temperature drops. This maintains a comfortable temperature for some time, reducing the need for supplementary heating during the early evening (see figure 6.5). For good winter performance, thermal mass should be exposed to direct sunlight and is best located in areas with unobstructed north-facing windows. An additional benefit is that some of the heat from lengthy periods of internal space heating can be stored in the thermal mass. Long after the heating is turned off, the slow release of heat from the walls or floor will maintain comfortable internal temperatures. Figure 6.5: Thermal mass in winter winter sun NEGATIVE WINTER EFFECTS In some cases thermal mass can actually increase winter energy requirements. Where there is little possibility of solar gain, either because north windows are too small or are overshadowed (poor solar access), the benefits provided by the use of thermal mass will be minimal. Each time supplementary heating is used, the thermal mass needs to be heated before the air temperature rises, increasing the heating energy needed. Increasing the area of north-facing glass can help offset this effect. outdoor air temperature air temperature inside double brick building on concrete slab 36 air-temperature inside timber building 28 summer temperatures 21 DAYTIME COMFORT ZONE 12 noon DAY 1 noon DAY 2 noon DAY 3 Figure 6.4: Comparing summer temperatures for buildings of different thermal mass Sustainable Energy Authority Victoria 2002 37

insulation insulation thermal mass Figure 6.6: Thermal mass within the insulated envelope Thermal mass and climate Thermal mass is particularly effective in places where there is a big difference in the maximum day temperature and minimum night temperature. In general, the greater the daily temperature range, the more thermal mass required. OF THE GREAT DIVIDING RANGE The climate north of the Great Dividing Range is different to that south of the Divide. Table 3.1 on page 11 shows average day and night temperatures for some Victorian locations. On average, Mildura has a hotter summer, warmer winter and greater day-night temperature range than Melbourne. Thermal mass provides greatest benefits in this situation. SOUTH OF THE GREAT DIVIDING RANGE For locations south of the Divide, summer comfort is usually a priority. Thermal mass provides real advantages in comfort terms and energy savings, enough to offset any potential winter disadvantage. ALPINE AREAS In alpine areas or cool climates, thermal mass is less important than insulation and correct sizing of glass areas. There is little need for thermal mass to moderate low summer temperatures, although it is not a disadvantage where heating is operating continuously, provided the building envelope is appropriately insulated. Figure 6.7: Solar radiation directly onto masonry walls and/or slab Locating thermal mass INSIDE THE INSULATED BUILDING ENVELOPE For maximum effectiveness, thermal mass should be insulated from external temperatures, i.e. it should be located within insulated walls. The benefits of thermal mass are considerably reduced if the external envelope is not insulated (see figure 6.6). For this reason brick veneer walls offer little thermal mass benefit, as the brick is on the outside of the insulated cavity. CONCRETE SLAB ON GROUND A concrete floor slab directly on the ground will take advantage of the huge thermal mass of the earth beneath. 38 ENERGY SMART HOUSING MANUAL

INSIDE -FACING ROOMS Using thermal mass in north-facing rooms should be a priority, particularly on those walls which receive direct winter sun. As the area of north-facing window increases, the more internal thermal mass is required to maintain a stable temperature (see figure 6.8). HOT ROOMS DURING SUMMER Locate thermal mass throughout the dwelling for summer comfort, but particularly in north, east and west-facing rooms (see figure 6.9). Shading of the windows to these rooms is also important. MASONRY FIREPLACES ON INTERNAL WALLS Masonry fireplaces are best located on internal rather than external walls so that the chimney can radiate additional heat into the rooms (see figure 6.10). AMOUNT OF THERMAL MASS High levels of thermal mass are beneficial throughout Victoria, with the exception of alpine areas and some situations where solar access is poor. While technical studies often recommend certain percentages of thermal mass for different construction types and climate zones, in practice most homes have thermal mass provided in only the following few locations. Floor: concrete slab or timber floor. External walls: double brick/masonry or brick veneer/weatherboard cladding. Internal walls: masonry or stud walls. Of all the material choices, the wall selection accounts for about 60 70% of the thermal mass of the building, with the floor area accounting for about 30 40%. Generally, the more thermal mass the better. A double brick or masonry home on a concrete slab offers the highest comfort benefits and energy savings. However, the cost of heavyweight materials can outweigh the value of energy savings. For this reason, use as much thermal mass as you can afford to achieve comfortable indoor conditions. In most cases, give first priority to provision of a concrete slab (substantially less cost than masonry walls) and supplement this with heavyweight walls where the building budget permits. radiant heat Figure 6.8: Locate thermal mass in north-facing rooms Figure 6.9: Use thermal mass in rooms that may overheat in summer Figure 6.10: Fireplaces on internal walls Sustainable Energy Authority Victoria 2002 39

black thermal mass white thermal mass 22 C 20 C Figure 6.11: Comparison of the effect of colour on room temperature The effect of floor coverings, colour and texture Surface colour and texture affect the heat absorption of thermal mass. SOFT FLOOR FINISHES Carpets laid over concrete slab floors tend to insulate the thermal mass of the slab from incoming heat. This delays its entry but also slows down its release. The net result is a temperature rise of 1 2 C, which is good in winter, but not so good in summer. This effect partly offsets the winter disadvantage of increased heating energy requirements due to absorption of heat by the thermal mass. While carpet lowers winter energy consumption, it increases summer energy requirements. Table 6.1 compares the effect on energy use of carpet and ceramic tiles on a concrete slab. Cork tiles are another soft floor finish with a similar insulating effect to carpet. Table 6.1: Effect of floor coverings on energy consumption (GJ) SLAB FLOOR COVERING CARPET CERAMIC TILES Heating 28.8 29.3 Cooling 11.3 6.0 Total 40.1 35.3 HARD FLOOR FINISHES A ceramic tiled finish on a concrete slab floor increases the thermal mass of the floor and the ability to store heat. This can improve cooling in summer (providing the windows are shaded) and works best for rooms with good north solar access. Other hard floor finishes, such as slate and vinyl tiles, have a similar effect on thermal mass performance. COLOURS Thermal mass that is coloured black absorbs more heat than white coloured material. Its effect on room temperature could be a 2 3 C year-round temperature rise (see figure 6.11). TEXTURES Textured surfaces, such as brick walls, have more exposed surface area and absorb more heat, while shiny or glossy surfaces absorb less heat than dull surfaces. WALL SURFACES An exposed brick wall absorbs more heat than a smooth plastered wall. The improved thermal storage of dark, textured walls should be balanced against the negative effect of such walls on internal light levels. Light-coloured reflective surfaces maximise both daylight and artificial light, whereas dark surfaces absorb light. 40 ENERGY SMART HOUSING MANUAL

Special construction types MUD BRICK Mud brick and rammed earth homes generally have thick walls (approximately 300 mm) and high thermal mass. When outside temperatures fluctuate above and below comfort temperatures, the high thermal mass of mud bricks considerably reduces heat transfer, performing particularly well in summer. In winter however, outside temperatures are normally lower than comfort temperatures and the low thermal resistance of mud brick leads to poor winter performance as heat is lost through the walls. Approximately six times as much heat passes through a mud brick or rammed earth wall compared to an insulated brick veneer wall. To reduce heat losses in winter, it is advisable to install external insulation to mud brick or rammed earth walls (see figure 6.12). Avoid fixing insulation to the internal face as this loses the thermal mass benefits of earth walls. If uninsulated mud brick or rammed earth is used, limit winter heat losses by keeping non-north windows as small as possible. All north windows should be double glazed and the area of north glazing should be at least 25 30% of the floor area, to help heat the building in winter. Ensure that windows are shaded in summer. REVERSE BRICK VENEER Reverse brick veneer, as the name suggests, puts the brickwork on the inside and timber framing on the outside i.e. the reverse of traditional construction. This form of construction enables a timber-style home to achieve the same level of thermal performance as a double-brick home. By reversing the traditional construction type, the high thermal mass of brickwork can be used to advantage. Instead of being on the outside of the insulation and hence isolated from the room, the brick skin is within the insulation envelope. Reverse brick veneer can be used in conjunction with either a concrete slab floor (see figure 6.13) or a timber floor (see figure 6.14). The heating needs for reverse brick veneer are somewhat higher than for traditional brick veneer, although the summer savings outweigh this. Reverse brick veneer does not have to be used for the entire home it may be used only for north-facing rooms. The external skin can be any type of lightweight cladding suitable for exterior use. TWO-STOREY DWELLINGS The upper storeys of homes have the potential to overheat in summer as they are usually of lightweight construction, with either brick veneer or weatherboard walls. To prevent overheating, upper levels should incorporate as much thermal mass as possible. Thermal mass can be provided by a suspended concrete slab floor, internal brick walls, the continuation of ground-floor double-brick construction, or any other technique that builds concrete or masonry into the structure. Windows to the east and west should be avoided or minimised because of the tendency to overheat. Limit the upper-storey window area to the north at less than 10% of the upper gross floor area. All windows should be effectively shaded and positioned to allow good cross-ventilation. 50 mm polystyrene mud and cement render applied over chicken wire reinforcing mesh insulation fixed to the outside of the mud brick (external insulation) Figure 6.12: Insulating mud brick walls insulation in external stud selected cladding brick internal wall concrete slab floor cavity inside insulation fixed to the outer side of the inner mud brick leaf (cavity insulation) Figure 6.13: Reverse brick veneer on concrete slab insulation in external stud brick internal wall selected cladding ground level strip footing suitable for both brickwork and stud frame Figure 6.14: Reverse brick veneer with timber floor timber floor Sustainable Energy Authority Victoria 2002 41