(For compliance with the new sewers for adoption regulation or building regulations part H1)

Similar documents
Product and Installation Guide

Product guide. TwinWall. Surface and Stormwater Drainage

Wavin: Range 600 Inspection Chambers

Adoptable and Non-Adoptable Assemblies.

DRAFT. Draft Bill of Quantities. Drainage

Below Ground Drainage, Water Supply, Utilities & Insulation

Hepworth SuperSleve Drainage Specification

7.00 MANHOLES AND INSPECTION CHAMBERS. Hunter Underground Systems

ULTRA3 UNDERGROUND DRAINAGE

BS EN :1998. Fittings Description Dia mm Code. Equal Junction. Double Socket

building the future PVC-UE Roofline, Window & Cladding Systems Soil & Waste Systems Underground Drainage Systems Rainwater Systems

OSMADRAIN UNDERGROUND DRAINAGE SYSTEM OSMADRAIN UNIVERSAL GULLY SYSTEM

UNDERGROUND DRAIN, SEWER, SURFACE WATER & DUCT

Polysewer Gravity Sewer System SPECIFICATION

Rodding Eye Details. Inspection Chambers

G632:G581 JR12 CI/SfB (52.7) In6 June 2015 OWIC001. Water management PRODUCT AND INSTALLATION MANUAL. Wavin. Inspection Chambers

Below Ground. Trade Price list. marleypd.co.uk MAY 2016

CPM Concrete Drainage Systems

Osma UltraRib System:

Densleeve. Description. Specification. Availability. 2 Tel: Fax:

Agrément Certificate 89/2206 website: Product Sheet 6

Integrated Manhole Ladder System

Product and installation manual. UltraRib. Foul and Surface Water Drainage

Installation Instructions for Perfect Manhole System DN 1200 DN PD 71 rev B 31/01/12

SIROPLAST-K. Pipe system for civil engineering subsoil drainage inspection chambers and subsoil drainage pipes to DIN

Ridgidrain NBS Specification

Perfect Manhole Installation Manual May 2012 Rev 8 Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints

Perfect Manhole System Precast concrete manholes with load bearing elastomeric joints Installation Manual

Regulations Detail Sheet 1

Terrain HDPE. Product Guide

Terrain Drainage Systems

Terrain Drainage Systems

ULTRARIB GRAVITY DRAINAGE AND SEWERAGE SYSTEM. WAVIN ULTRARIB 150 mm, 225 mm AND 300 mm INTERNAL DIAMETER PIPES AND FITTINGS

SANITARY WASTE AND VENT PIPING

Metro Drain & N-Drain

Below ground System of pipework required to carry waste fluids from building to disposal site.

Shower and Floor Gullies SECTION

G632:G77 JR12/JR13 A16 J34 X71 CI/SfB (52.7) In6 (Y2) June 2015 OD107. Waste water drainage PRODUCT AND INSTALLATION MANUAL.

Product. Department of Transport Requirements. Marley Extrusions Ltd Lenham Nr Maidstone Kent ME17 2DE Tel: Fax:

Installation Procedure FP McCann DN1050 Easi-Pit

PVC Fittings & Laterals for Solid-Wall PVC Sewer Pipe

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

A. This Section includes sanitary waste and vent piping inside the building and to locations indicated.

Installation Overview

For more information on ACO Drain visit

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

R10 RAINWATER DRAINAGE SYSTEMS

CI/SfB (52.5) X June 2008 CH301. Domestic Channel Drainage Systems. Product Guide

ACO Building Drainage

A reliable solution for ditching, underpassing and rainwater drainage

SECTION STORM UTILITY DRAINAGE PIPING PART 1 - GENERAL 1.1 SUMMARY 1.2 SUBMITTALS 1.3 PROJECT CONDITIONS

DRAINAGE SYSTEMS FOR BELOW GROUND

H A P A S Roads and Bridges Agrément Certificate No 02/H068 Second issue*

SECTION (15150) - SANITARY WASTE AND VENT PIPING

t y p e V S A S E W A G E P U M P

SECTION FACILITY SANITARY SEWERS

SPECIFICATION FOR PIPE CULVERT CONSTRUCTION

component developments Stainless Steel Industrial Floor Drainage

Product, Design and Installation Guide. Rainwater Systems FOR RESIDENTIAL, COMMERCIAL AND INDUSTRIAL APPLICATIONS

L7315+L21233 J342 X2. CI/SfB (52.5) If9 FOR RESIDENTIAL AND LIGHT COMMERCIAL APPLICATIONS

Selection & Installation

Bridge Drainage Systems

Uponor Ltd Aycliffe Industrial Estate Newton Aycliffe Co Durham DL5 6EA Tel: Fax:

CI/SfB Oct 12 (52.5) Uniclass L7314

Summary of the 2011 Changes

DRAINAGE SYSTEMS.

VSS S U B M E R S I B L E S E W A G E P U M P S

Standard products Tasmania 2010

NELSON CITY COUNCIL INFRASTRUCTURAL ASSETS SD 601 APPROVED SENIOR EXECUTIVE INFRASTRUCTURE

CI/SfB Oct 12 (52.5) Uniclass L7314

Daytona Beach Pier Building Renovation Jun 2010

ONE PIPE LENGTH MAX (REFER TO 1/4"/FT SLOPE (MIN) 5'-0" (MIN) OR 4" LATERAL NOTE #1) INCREASER RIGHT-OF-WAY/ 4"x6" REFER TO TYPICAL EXCAVATION,

WAVIN ROAD GULLIES. Date of First issue: 16 April 2014 Brian Chamberlain Claire Curtis-Thomas

Infiltration and Attenuation Systems Product and Installation Guide

List of products of harmonised standards Code 28: PIPES-TANKS AND ANCILLARIES NOT IN CONTACT WITH WATER INTENDED FOR HUMAN CONSUMPTION

Birco. Water Linear Management Drainage Design Guide Birco Introduction Linear Drainage Channel. Grate Drainage System

PRECAST RECTANGULAR CHAMBERS

TITLE: SLAUGHTER HOUSE SEPTIC TANK. ITEM No. D E S C R I P T I O N UNIT QTY

PowerDrain Section. Technical Handbook and Product Catalog. Heavy duty trench drainage

JR12:L731/L71121/L2123 J3413:X721 CI/SfB (52.5) (H1) October 2015 WM424. Water management PRODUCT AND INSTALLATION MANUAL.

Drexus Pave Drain. Linear Channel. Water Management. Water Linear Management Drainage Design Guide Drexus Pave Drain Linear Drainage Channel

Khalid SINCE 1997 TECHNICAL MANUAL 2017 GRP MANHOLE LINER & ACCESSORIES

PERMANENT PAVEMENT REPAIR NO SCALE

Ultimate Pipeline Systems POWER PLASTIC FACTORY LLC.

CONSTRUCTION SPECIFICATION FOR THE INSTALLATION OF ELECTRICAL CHAMBER

DUCTILE IRON PIPES AND FITTINGS DETAILED PRODUCTS SPECIFICATIONS

112mm. 117x75mm Polyflow. 130x70mm Ogee 68mm Round 65mm Square. 112mm Half Round 68mm Round. 65mm. Round. 112mm. 117x75mm Polyflow

Wavin AS Acoustic Soil System

Approved Document. Drainage and waste disposal. The Building Regulations 2010

11/30/12 T.P V1.0. Pipex px Product Group: Manholes, Chambers & Tanks Pipex px Product Type: Combined Sewer Overflow CSO

Drainage & Plumbing Systems

AWASHAFT DN400. Product and Installation Guide

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Design. Introduction. Our Commitment to Specifiers. Section 9 Page 1

Pluvia Product and Installation Guide

RIDGIDRAIN ADVANCED DRAINAGE SYSTEM PRODUCT SHEET 1 RIDGIDRAIN PLUS AND RIDGIDRAIN 100 MM TO 600 MM PIPES AND COUPLERS

University of Delaware

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

PRODUCT GUIDE PLUMBING. February 2017 BRETT MARTIN PLUMBING SYSTEMS PRODUCT RANGE INSTALLATION DETAILS PLUMBING SYSTEMS

Transcription:

Plastic Drainage Keyline offers a comprehensive range of products suitable for all building, foul, surface water and land drainage applications - including new innovative, cost-effective systems for compliance with the amended Building Regulations Part H (England and Wales) and the Scottish Building Standards technical handbooks.

NOW UPDATED FOR SfA7! (For compliance with the new sewers for adoption regulation or building regulations part H1) Civils and Drainage Solutions The Essential Guide Plastic Drainage 87

Civils and Drainage Solutions The Essential Guide Plastic Drainage 88 New regulations for inspection chambers What s changed New rules and regulations about drainage are now in force. Here are the main things you need to know: Adoptable drainage now extends further than before l Foul and surface water drains which serve more than one property, and connect to public sewers, are now part of adopted drainage A new 7 th edition of Sewers for Adoption [SfA7] has been published l This includes required standards and installation details for installing and connecting inspection chambers Plastic inspection chambers are now fully-authorised for adoptable installations SfA7 includes specific details for flexible (plastic) chambers: l Type 4 chamber to max. 2 metres depth l Type 3 chamber to max. 3 metres depth New British Standard for chambers: BS EN 13598 BS EN 13598 will supercede BS 7158 from January 2013. It has two parts: l Part 1 for installations to max. 1.2m depth (or to 0.9m depth if inspection chamber shaft is less than 450mm dia.) l Part 2 for installations to 3m depth...and what hasn t changed Building Regulations still apply to non-adoptable drainage l Foul and surface water drains which serve non-adoptable installations remain unchanged. NOTE: Non-adoptable chambers are highlighted on the illustration overleaf Inspection chambers in non-adoptable locations must comply with these chamber types in Part H1 of Building Regulations: l Shallow to max. 0.6m depth for chamber shafts under 450mm dia. or max.1.2m depth if shaft is 450mm dia. or more l Deep exceeding 1.2m depth for chambers with shafts min. 450mm dia. NOTE: BS EN 13598 also applies to non-adoptable chambers NOW UPDATED FOR SfA7!

Wavin Chambers, a comprehensive choice Whatever the installation requires, Wavin has exactly the inspection chamber you need. This table gives you a summary of our chamber ranges and essential information relevant to your selection. No. of Inlets Inlet Sizes (mm OD) Base Type Max Invert Base Dia. SfA7 Depth* (m) (mm) Type 1 2-3 4-5 110 150 160 225 300 Shallow 0.6 250 4* Multi-Base 0.9 300 4* Mini Access 0.9 315 4 PPIC 1.2 475 4 Universal 1.2 450 4* Range 200 2.0 200 4 Range 315 2.0 315 4 Range 500 3.0 500 3, 4 Range 600 3.0 600 3, 4 * NOTE: Maximum invert depths shown are for individual base types. Under SfA7 and Building Regulations, maximum permitted depth can be less. Using the selectors FIRST, check the following about the chamber you need to install: 1. Will it be Adoptable or Non-adoptable? See overleaf if in doubt. 2. How many inlet connections are needed into the chamber base? If there are 2 or more inlets, the selectors will help you identify the ideal chamber base configuration for the job. 3. What size pipe connections are required for the chamber? Adaptors may be needed in some cases. 4. At what depth do you need to install it? There are statutory installation depth limits applicable (see inside) and some chamber ranges have their own design depth limits. NOW, apply this information to the relevant selector (Adoptable or Non-adoptable). See selectors on pages 92 and 94 to help you identify the recommended chamber base. Civils and Drainage Solutions The Essential Guide Plastic Drainage 89

Civils and Drainage Solutions The Essential Guide Plastic Drainage 90 5a 5a NOW UPDATED FOR SfA7! 1a 3a 1p 2a 2a 2a 1p 3a 4a 3a 3p FOR COMPLIANCE WITH NEW SEWERS FOR ADOPTION SfA7 or BUILDING REGULATIONS PART H1

KEY Foul Water a = Adoptable Surface Water p = Private OSMA Shallow, OSMA Multi-Base or Hepworth Mini Access Standards BS EN 13598-1 a SfA7 Chamber detail Type 4 Shallow (0.6m max invert) Multi-Base/Mini Access (0.9m max invert) Building regulations Part H1, Shallow (0.6m max invert) 1 Wavin Range 315 Standards BS EN 13598-2 a SfA7 Chamber detail Type 4 (2.0m max invert) Building regulations Part H1, Shallow (0.6m max invert) OSMA Universal or Hepworth PPIC Standards BS EN 13598-1 a SfA7 Chamber detail Type 4 (1.2m max invert) Building regulations Part H1, Shallow (<1.2m max invert) 2 Wavin Range 200 Standards BS EN 13598-1 a SfA7 Chamber detail Type 4 (2.0m max invert) Building regulations Part H1, Shallow (0.6m max invert) 3 5 Wavin Range 600 Standards BS EN 13598-2 a SfA7 Chamber detail Type 3 or 4 (3.0m max invert) Building regulations Part H1, Deep (>1.2m max invert) 4 Civils and Drainage Solutions The Essential Guide Plastic Drainage 91

Civils and Drainage Solutions The Essential Guide Plastic Drainage 92 CHAMBERS SELECTOR: for ADOPTABLE applications REQUIRED COMPLIANCE TO Sewers for Adoption 7 th ed. [SfA7] MAX. PERMITTED DEPTH under Sewers for adoption 7 th ed. [SfA7] 2.0m max. 2.0m max. 3.0m max. and BS EN 13598-1 /or BS EN 13598-2 <1.2m max. (<0.9m max. if shaft <180mm dia.) <3.0m max. <3.0m max. HOW MANY INLETS do you need to allow for? CONFIGURATION OPTIONS SfA7 Inspection Chamber Detail Type 4 SfA7 Inspection Chamber Detail Type 4 SfA7 Inspection Chamber Detail Type 3 to BS EN 13598 Part 1 to BS EN 13598 Part 2 to BS EN 13598 Part 2 1 2-3 4-5 1 2-3 4-5 1 2-3 4-5 NOW UPDATED FOR SfA7! Straight channel Shallow IC*: 4D960 Multi-Base IC: 4D910 Mini Access: SDAC1/1 Range 200: 24/26NE300 Range 315: 34/36NE300 Bent channel at 90 Multi-Base IC: 4D918 Mini Access s : SDAC1/1 Range 200 s : 24/26NE300 Range 315 s : 34/36NE300 Range 500 s : Bent channel at 30 Shallow IC s : 4D960 Multi-Base IC s : 4D910 Mini Access s : SDAC1/1 Range 200 s : 24/26NE300 Range 315 s : 34/36NE300 Range 500 s :

Inlet(s) at 90 Single side (LH or RH) Multi-Base IC: 4D911 4D912 Mini Access: SDAC1/1 Range 315 s : 34NE303 36NE303 Inlet(s) at 90 Both sides Multi-Base IC: 4D935 Mini Access s : SDAC1/1 Range 315 s : 34NE303 36NE303 Inlet(s) at 45 Single side (LH or RH) Multi-Base IC: 4D913 4D914 Mini Access: SDAC1/1 Range 315: 34NE301 34NE302 36NE301 36NE302 Inlet(s) at 45 Both sides Shallow IC*: 4D960 Mini Access: SDAC1/1 Range 315: 34NE303 36NE303 Inlets at 90 & 45 Single side (LH or RH) Multi-Base IC: 4D933 4D934 56NE 310 Inlets at 90 & 45 Both sides Universal IC: 4D922 6D929 6UR929 Universal IC: 4D922 6D929 6UR929 For details of Shallow, Multi-Base and Universal Inspection Chambers, see Plastic Drainage section For details of Mini Access and PPIC, see Clay Drainage section * Shallow Inspection Chamber 4D960 maximum installation depth: 0.6m s Additional bends required for this configuration Civils and Drainage Solutions The Essential Guide Plastic Drainage 93

Civils and Drainage Solutions The Essential Guide Plastic Drainage 94 CHAMBERS SELECTOR: for NON-ADOPTABLE applications REQUIRED COMPLIANCE TO Building Regulations 2010 Approved Document H Building Regulations H1 Building Regulations H1 Building Regulations H1 to BS 7158 and BS EN 13598 Part 1 to BS 7158 and BS EN 13598 Parts 1 and 2 to BS 7158 and BS EN 13598 Part 2 MAX. PERMITTED DEPTH under BUILDING REGULATIONS H1 (Shallow) <0.6m (Shallow) <1.2m (Deep) >1.2m and BS EN 13598-1 /or BS EN 13598-2 <1.2m max. (<0.9m max. if shaft <190mm dia.) BS EN 13598-1: <0.9m max. BS EN 13598-2: <3.0m max. <3.0m max. NOW UPDATED FOR SfA7! HOW MANY INLETS do you need to allow for? 1 2-3 4-5 1 2-3 4-5 1 2-3 4-5 CONFIGURATION OPTIONS Straight channel Shallow IC*: 4D960 Multi-Base IC: 4D910 Mini Access: SDAC1/1 Universal IC: 4D922 6D928 6UR928 Bent channel at 90 Multi-Base IC: 4D918 Mini Access s : SDAC1/1 Universal IC s : 4D922 6D928 6UR928 PPIC s : Range 500 s : Bent channel at 30 Shallow IC s : 4D960 Multi-Base IC s : 4D910 Mini Access s : SDAC1/1 Universal IC s : 4D922 6D928 6UR928 PPIC s : Range 500 s :

Inlet(s) at 90 Single side (LH or RH) Multi-Base IC: 4D911 4D912 Mini Access: SDAC1/1 Universal IC: 4D922 6D928 6UR928 Inlet(s) at 90 Both sides Multi-Base IC: 4D935 Mini Access s : SDAC1/1 Universal IC: 4D922 6D928 6UR928 Inlet(s) at 45 Single side (LH or RH) Multi-Base IC: 4D913 4D914 Mini Access: SDAC1/1 Universal IC: 4D922 6D929 6UR929 Inlet(s) at 45 Both sides Shallow IC*: 4D960 Mini Access: SDAC1/1 Universal IC: 4D922 6D929 6UR929 Inlets at 90 & 45 Single side (LH or RH) Multi-Base IC: 4D933 4D934 Universal IC: 4D922 6D929 6UR929 Inlets at 90 & 45 Both sides Universal IC: 4D922 6D929 6UR929 Universal IC: 4D922 6D929 6UR929 Universal IC: 4D922 6D929 6UR929 Universal IC: 4D922 6D929 6UR929 For details of Shallow, Multi-Base and Universal Inspection Chambers, see Plastic Drainage section For details of Mini Access and PPIC, see Clay Drainage section * Shallow Inspection Chamber 4D960 maximum installation depth: 0.6m s Additional bends required for this configuration Civils and Drainage Solutions The Essential Guide Plastic Drainage 95

Civils and Drainage Solutions The Essential Guide Plastic Drainage 96 OsmaDrain and UltraRib Dimensions and Availability Product 1. OsmaDrain Nominal Diameter mm 82* 110* 150/160* 225 300 375 450 500 600 Solid yes yes yes no no no no no no 3 & 6 Slotted no yes yes no no no no no no 6 Pipe Length m 2. UltraRib no no yes yes yes no no no no 3 & 6 1. OsmaDrain: building drainage connections to main sewers The OsmaDrain system includes a wide range of bends, junctions, and other fittings, including inspection chambers and adaptors, allowing connection to traditional cast iron and clayware drains. 2. UltraRib: foul and surface water drainage The pipe is available socketed and plain ended in a choice of lengths. There is a full range of bends, junctions, and other fittings, including adaptors allowing connection to, for example, cast iron and clayware drains. * 82, 110 and 160mm OsmaDrain pipes are described by the outside diameter; all other pipes are described by the inside diameter.

OsmaDrain: building drainage connections to main sewers The OsmaDrain system is designed for use in gravity drainage installations at depths of up to 10m, with outfalls into Local Authority sewers, private treatment plants, and cesspools, and for surface water drainage into soakaways or watercourses. Available in diameters of 82, 110 and 160mm the OsmaDrain system, includes a comprehensive range of fittings to accommodate all installation requirements. PVC-U provides superior self-cleansing properties at low velocities and this can often help to reduce excavation depths and permit the use of smaller diameter pipes, as well as possibly obviating the need for a pumped system. OsmaDrain 82mm System 3D073 P/E Pipe - 3m 794981 3D076 P/E Pipe - 6m 712034 3D105 D/S Slip Coupler 712035 3D116 Snap Cap (spare) 794983 3D130 T Ring (spare) 794985 3D161 S/S Bend - 87 1 2 712038 3D163 S/S Bend - 45 712039 3D190 S/S Junction - 87 1 2 712040 3D205 D/S Pipe Coupler 794986 3D206 P/E Adaptor 68mm RW Pipe 882256 3D561 D/S Bend - 87 1 2 794987 Civils and Drainage Solutions The Essential Guide Plastic Drainage 97

Civils and Drainage Solutions The Essential Guide Plastic Drainage 98 OsmaDrain 110mm System 4D066 P/E Slotted Pipe - 6m 712245 4D073 P/E Pipe - 3m 710578 4D076 P/E Pipe - 6m 710579 4S085 Socket Bracket Brace Assembly 813564 4S086 Pipe Bracket Assembly 818101 4D095 S/S Reducer - 110mm x 82mm 710032 4D104 D/S Coupler (for slotted pipe) 758730 4D105 D/S Slip Coupler 710580 4D107 S/S Adaptor - to clay socket 710581 4D115 S/S Settlement Socket 758733 4D116 Snap Cap and Seal 710583 4D124 S/SW Coupler 710585 4D128 S/S Adaptor - to clay spigot 710584 4D129 D/S Adaptor - to thinwall clay 712046 4D131 Protection Sleeve 710586 4D149 Rainwater Adaptor x 68mm 710582 4D159 Universal Drain Adaptor 816358 4D161 S/S Bend - 87 1 2 710587 4D162 S/S Bend - 67 1 2 710588 4D163 S/S Bend - 45 710589 4D166 S/S Bend - 30 710590 4D167 S/S Bend - 15 710591 4D168 S/S Bend - 11 1 4 712006 4D169 S/S Access Bend - 87 1 2 710592 4D173 S/S Adjustable Bend - 30 712242 - for variable angles up to 30, rotate segments to achieve required angle 4D181 S/S LR Bend - 87 1 2 711861

OsmaDrain 110mm System cont. 4D183 S/S LR Bend - 45 710593 4D190 S/S Equal Junction - 87 1 2 710594 4D193 D/S Equal Junction - 87 1 2 710595 4D205 D/S Pipe Coupler 710596 4D210 S/S Equal Junction - 45 710597 4D213 D/S Equal Junction - 45 710598 4D274 S/S Access Pipe 710599 4D281 P/E LR Bend - 87 1 2 758751 4D283 P/E LR Bend - 45 890955 4D290 S/S Screwed Access Cover 711862 4D292 P/E Screwed Access Cover 710600 - allows full bore access to the drainage system for cleaning, fits into standard OsmaDrain ring seal socket 4D295 Temporary Site Cap 935063 4D296 P/E Socket Plug 710601 - incorporates one closed boss socket position, will form either a 32mm, 40mm or 50mm waste pipe connection when fitted with the appropriate boss socket adaptor 4D297 P/E Socket Plug (open) 758731 4D298 Internal Drain Connector - 32/40mm 870066 4D299 Internal Drain Connector - 50mm 870067 4D314 Ring Seal for 4D325 (spare) 711900 4D317 Rodding Eye Gasket - oval (spare) 758734 4D318 Rodding Eye Screws - new style (pkt 4) 838181 4D325 S/S Cover & Frame - 250mm diameter 710039 - suitable for use in situations requiring a maximum loading of up to 10kN (1T), where the frame of the cover is supported in service by a concrete plinth Civils and Drainage Solutions The Essential Guide Plastic Drainage 99

Civils and Drainage Solutions The Essential Guide Plastic Drainage 100 OsmaDrain 110mm System cont. 4D328 S.I.C. Cover (spare) 794988 4D360 P/E Square Rodding Eye 988730 4S380 Cleaner - 250ml can 860838 4S383 Solvent No. 2-125ml can 860839 4S384 Solvent No. 2-250ml can 860840 4D391 Soluble Lubricant - 0.5kg tub 712044 4S392 Silicone Lubricant Spray - 400ml 523524 4S394 Solvent Cement Filler - 200g tube 792362 4D395 Soluble Lubricant - 2.5kg tub 794989 4D398 S/S Boss Adaptor - 1 1 4/32 794990 4D399 S/S Boss Adaptor - 1 1 2/40 711860 4D418 Inspection Junction Washers (pkt 4) 758736 4D420 S/S Inspection Pipe 869435 4D421 Inspection Junction Gasket (spare) 758741 4D492 S/S Equal Double Inspection Junction 869436 4D494 Inspection Junction Plug (spare) 869437 4D500 S/S Universal Gully Trap 710606 4D503 SW/S Plain Hopper 710607 4D504 SW/S Vertical Inlet Hopper 710608 4D505 Vertical Inlet Cover (spare) 710609 4D506 Universal Gully Grating (spare) 710610 4D507 P/E Plain Hopper 710612 4D508 P/E Vertical Inlet Hopper 710613 - with 150mm long spigot 4D526 Sealed Access Plate 710616 4D527 P/E Sealed Access Hopper 710615 4D561 D/S Bend - 87 1 2 710618 4D562 D/S Bend - 67 1 2 710619

OsmaDrain 110mm System cont. 4D563 D/S Bend - 45 710620 4D566 D/S Bend - 30 710621 4D567 D/S Bend - 15 710622 4D568 D/S Bend - 11 1 4 712007 4D569 D/S Access Bend - 87 1 2 710623 4D573 D/S Adjustable Bend - 30 712241 4D581 D/S LR Bend - 87 1 2 710624 - satisfies recommendations of BS 5572: 1994 for base of soil stack applications. Manufactured with cut out marks to convert to a Channel Bend for use within traditional manholes 4D583 D/S LR Bend - 45 710625 4D585 D/S LR Channel Bend - 90 711878 4D587 D/S LR Channel Bend - 45 794991 4D589 S/S Bossed Pipe 710626 4D593 D/S Access Junction - 87 1 2 710627 4D700 S/S Bottle Gully 943614 4D701 S/S Yard Gully 943615 4D702 Sealed Access Cover 943616 4D706 Vertical Inlet Grating & Frame 846302 4D708 Square Grating and Frame 525075 4D800 P/E Trapped Yard Gully 817733-600mm overall depth, supplied complete with removable rubber bung for rodding access 4D810 DI Grating/Frame - B125 817734 4D815 Perforated Catchment Bucket 817735 4D900 S/S Bottle Gully - 87 1 2 711865 - provides access to the drainage system for cleaning, supplied with all bosses closed Civils and Drainage Solutions The Essential Guide Plastic Drainage 101

Civils and Drainage Solutions The Essential Guide Plastic Drainage 102 OsmaDrain 110mm System cont. 4D901 S/S Bottle Gully - 87 1 2 (open) 712242 4D902 Access Liner for 593 (spare) 712246 4D904 Screwed Access Cap (spare) 758743 4D906 Bottle Gully Grating (spare) 758761 4D908 Bottle Gully Cover and Frame (spare) 758754 4D909 Access Liner for Bends (spare) 758744 4D910 D/S Multi-base IC Base - straight 813825 4D911 D/S Multi-base IC Base - single 90 - LH 813831 4D912 D/S Multi-base IC Base - single 90 - RH 813832 4D913 D/S Multi-base IC Base - single 45 - LH 813833 4D914 D/S Multi-base IC Base - single 45 - RH 813834 4D915 Sealed Access Cover 758762 4D916 Bottle Gully Riser 860966 4D917 D/S Multi-Base IC Base - double 45 813835 4D918 D/S Multi-Base IC Base - bend 90 813836 4D919 DI Grating for 4D900/901 845564 4D922 D/S Universal IC Base - 270mm invert 712243-110mm straight main channel with four 110mm (2 x 45 and 2 x 90 ) right/left hand branch entries. Supplied with 3 blank-off plugs for use in unused side entries 4D923 D/S Equal NIC Base 110mm x 110mm 538723 4D920 PP Square Cover & Frame 634092 4D924 PP Round Cover & Frame - Restrictor 885497 4D926 Universal IC Plug (spare) 710637 4D927 PP Round Cover & Frame 639093 4D930 Inspection Junction Cover - small (spare) 758745 4D932 Universal IC Sealant (spare) 758764 4D933 D/S Multi-Base IC Base - twin LH 813837 4D934 D/S Multi-Base IC Base - twin RH 813838

OsmaDrain 110mm System cont. 4D935 D/S Multi-Base IC Base - double 90 813840 4D937 P/E Multi-Base IC Shaft - 150mm 813849 4D942 DI Cover/Frame - B125 878277 4D945 Square Recessed Steel Cover/PP Frame 878280 4D946 Square Recessed Steel Cover/PP Frame - sealed 878284 4D948 Chamber Channel Cover - LH 758755 4D949 Chamber Channel Cover - RH 758756 4D955 Lifting Keys 878294 4D957 MB Shaft Seal (spare) 838183 4D960 D/S Shallow IC - 600mm 758749-600mm invert depth, supplied with 2 profiled, blank-off plugs for use in unused side entries 4D961 P/E Sealed Cover/Adjacent Frame 870068-250mm diameter - suitable for use in situations requiring a maximum loading of up to 10kN (1T) where the frame is supported in service by a concrete plinth 4D964 Shallow IC Plug (spare) 758750 4D969 P/E Multi-Base Cover/Frame 813851 4D992 Access Cap Gasket (spare) 758748 4D993 Bottle Gully Plug - new style (spare) 838184 4D975 Inspection Chamber Shaft - 450mm diameter 696909 Civils and Drainage Solutions The Essential Guide Plastic Drainage 103

Civils and Drainage Solutions The Essential Guide Plastic Drainage 104 OsmaDrain 160mm System 6D066 P/E Slotted Pipe - 6m 758501 6D073 P/E Pipe - 3m 712008 6D076 P/E Pipe - 6m 711892 6S085 Socket Bracket Brace Assembly 757995 6S086 Pipe Bracket Assembly 757996 6D099 S/S Reducer - 160mm x 110mm 711893 6D104 D/S Coupler (for slotted pipe) 758502 6D105 D/S Slip Coupler 758499 6D116 Snap Cap (spare) 758504 6D124 S/SW Coupler 710049 6D128 S/S Adaptor - to clay spigot 710050 6D129 D/S Adaptor 794993 - to thinwall clay. Connector to BS EN 295 thin wall clay spigot 6D130 T Ring (spare) 710051 6D131 Protection Sleeve 710052 6D161 S/S Bend - 87 1 2 710053 6D163 S/S Bend - 45 710054 6D166 S/S Bend - 30 710055 6D167 S/S Bend - 15 710056 6D190 S/S Equal Junction - 87 1 2 710058 6D193 D/S Equal Junction - 87 1 2 711894 6D198 S/S Unequal Junction - 87 1 2 710059 6D199 D/S Unequal Junction - 87 1 2 758496 6D205 D/S Pipe Coupler 710060 6D210 S/S Equal Junction - 45 710061 6D213 D/S Equal Junction - 45 711895 6D218 S/S Unequal Junction - 45 710062 6D219 D/S Unequal Junction - 45 711901 6D274 S/S Access Pipe 710063 6D281 P/E LR Bend - 87 1 2 710122

OsmaDrain 160mm System cont. 6D283 P/E LR Bend - 45 794994 6D290 S/S Screwed Access Cover 711896 6D292 P/E Screwed Access Cover 710064 - allows full bore access to the drainage system for cleaning, fits into a standard OsmaDrain ring seal socket 6D296 P/E Socket Plug 710065 6D360 P/E Square Rodding Eye 988729 6D561 D/S Bend - 87 1 2 710073 6D563 D/S Bend - 45 710074 6D566 D/S Bend - 30 710075 6D567 D/S Bend - 15 710076 6D917 NIC Ring Seal (spare) 995456 6D928 D/S Equal Inspection Base - 160mm x 160mm 857459 6D929 D/S Unequal Inspection Base - 160mm x 110mm 857460-160mm straight main channel with four 110mm (2 x 45 and 2 x 90 ) right/left hand branch entries. Supplied with 3 blank-off plugs for use in unused side entries 6D932 350mm Restrictor Ring (spare) 717790 6D936 D/S Equal NIC Base - 160mm x 160mm 995429-160mm straight main channel with two 160mm x 90 right/left hand branch entries. Supplied complete with sealing ring and one blank-off plug for use in unused side entries Civils and Drainage Solutions The Essential Guide Plastic Drainage 105

Civils and Drainage Solutions The Essential Guide Plastic Drainage 106 OsmaDrain 160mm System cont. 6D937 D/S Unequal NIC Base - 160mm x 110mm 995430-160mm straight main channel with four 110mm (2 x 90 and 2 x 45 ) right/left hand branch entries. Supplied complete with sealing ring and three blank-off plugs for use in unused side entries 6D938 NIC Inspection Chamber Shaft - 3m length 995435 - for use with 4D923, 6D936 and 6D937 NIC bases 6D934 NIC Shaft 1.5m length 507163 Tool and equipment hire available Call 0844 892 1877

UltraRib: foul and surface water drainage UltraRib is a PVC-U pipe system designed for adoptable sewer installations. The pipe has a smooth inner surface and is reinforced externally with a pattern of integral, concentric ribs which provide exceptional axial rigidity and enhanced radial strength without a significant increase in weight. UltraRib pipes & fittings (where applicable) comply with the following: BS EN 13476-3 plastics piping systems for non-pressure underground drainage & sewerage Water industry specifications (WIS): WIS 4-35-01 July 2000: Issue 1 The system employs fully socketed joints for security and ease of installation. The design of the socket prevents accidental displacement of the O ring during installation, and the resulting joint provides a flush fit between the internal bore of the pipe and the fitting. The assembled joint provides built-in accommodation for differential movement without damage. UltraRib 150mm System 6UR043 S/S Pipe - 3m 800813 6UR046 S/S Pipe - 6m 800814 6UR073 P/E Pipe - 3m 800808 6UR099 S/S Reducer - 150mm x 110mm 800831 - level invert reducer to BS EN 1401 OsmaDrain spigot 6UR105 D/S Slip Coupler 800816 6UR106 D/S Adaptor - to clay or concrete spigot 800820 6UR117 Ring Seal (spare) 800902 6UR128 S/S Adaptor 800818 - connector to BS 1211 or BS 437 cast iron spigot or BS EN 245 clay spigot 6UR129 D/S Adaptor - to thinwall clay spigot 800822 Civils and Drainage Solutions The Essential Guide Plastic Drainage 107

Civils and Drainage Solutions The Essential Guide Plastic Drainage 108 UltraRib 150mm System cont. 6UR141 S/S Adaptor - to BS EN 1401 spigot 800828 6UR142 D/S Adaptor - to BS EN 1401 socket 800829 6UR143 S/S Adaptor - to BS EN 1401 socket 800830 6UR163 S/S Bend - 45 521734 6UR193 D/S Equal Junction - 87 1 2 800843 6UR199 D/S Junction (150 x 110) - 87 1 2 800845 6UR205 D/S Pipe Coupler 800817 - for jointing UltraRib pipe 6UR213 D/S Equal Junction - 45 800844 6UR219 D/S Junction (150 x 110) - 45 800846 6UR290 S/S Screwed Access Cover 800879 6UR292 P/E Screwed Access Cover 800878 - fits into an UltraRib socket to allow full access to the sewerage system for cleaning 6UR296 P/E Socket Plug 806542 6UR395 Soluble Lubricant - 2.5kg tub 833443 6UR396 Soluble Lubricant - 5kg tub 833444 6UR560 D/S Bend - 87 1 2 - to BS EN 1401 spigot 800832 6UR561 D/S Bend - 87 1 2 800839 6UR563 D/S Bend - 45 800840 6UR566 D/S Bend - 30 800841 6UR567 D/S Bend - 15 800842 6UR590 S/S Road Gully - 350mm diameter 995278 6UR600 S/S Road Gully 816362-450mm diameter x 900mm overall depth trapped road gully

UltraRib 150mm System cont. 6UR869 S/S Rocker Pipe 806543 4D975 Universal Inspection Chamber Shaft 696909-450mm diameter 305mm deep 6UR928 D/S Equal Inspection Chamber Base 450mm 857470 diameter - 150mm x 150mm - 150mm straight main channel with two 150mm x 90 right/left hand branch entries. Supplied with one blank-off plug for use in unused side entry 6UR929 D/S Unequal Insp Base - 150mm x 110mm 857481 6D934 NIC Shaft 1.5m length 507163 6D931 P/E Polypropylene Square Cover and Frame 717783 6UR936 D/S Equal NIC Base 150mm x 150mm 995432 6UR937 D/S Unequal NIC Base 150mm x 110mm 995433-150mm straight main channel with four 110mm (2 x 90 and 2 x 45 ) right/left hand branch entries. Supplied complete with sealing ring and three blank-off plugs for use in unused side entries 6D938 NIC Inspection Chamber Shaft - 3m length 995435 - for use with 6UR936 and 6UR937 NIC bases 6D940 NIC Telescopic Adaptor 848035 Civils and Drainage Solutions The Essential Guide Plastic Drainage 109

Civils and Drainage Solutions The Essential Guide Plastic Drainage 110 UltraRib 150mm System cont. 4D942 Dl Cover/Frame - B125 878277 4D920 PP Square Cover & Frame - 450mm 639092 - Restricted access Committed to Environmentally Responsible Sourcing 4D924 PP Round Cover & Frame - 450mm 885497 4D955 Lifting Keys 878294 6UR993 Testing Plug 800901

UltraRib 225mm System 9UR043 S/S Pipe - 3m 833450 9UR046 S/S Pipe - 6m 833451 9UR073 P/E Pipe - 3m 833448 9UR095 S/S Reducer - 225mm x 150mm 833453 - level invert reducer 9UR105 D/S Slip Coupler 833454 9UR109 D/S Adaptor - to clay spigot 833455 9UR117 Ring Seal (spare) 833456 9UR205 D/S Pipe Coupler 833457 9UR213 D/S Equal Junction - 45 833458 9UR224 D/S Junction (225 x 110) - 45 833459 9UR226 D/S Junction (225 x 160) - 45 833461 9UR227 D/S Junction (225 x 150) - 45 833462 9UR229 D/S Slip Junction (225 x 150) - 45 844978 9UR296 P/E Socket Plug 833464 9UR561 D/S Bend - 90 833467 9UR563 D/S Bend - 45 833468 9UR566 D/S Bend - 30 833470 9UR567 D/S Bend - 15 833472 9UR869 S/S Rocker Pipe 833494-600mm effective length Civils and Drainage Solutions The Essential Guide Plastic Drainage 111

Civils and Drainage Solutions The Essential Guide Plastic Drainage 112 UltraRib 300mm System 12UR043 S/S Pipe - 3m 833516 12UR073 P/E Pipe - 3m 833511 12UR093 S/S Reducer - 300mm x 225mm 833518 - level invert reducer 12UR105 D/S Slip Coupler 833520 - for new branch connections and repairs 12UR112 D/S Adaptor - to concrete spigot 833523 12UR117 Ring Seal (spare) 833526 12UR205 D/S Pipe Coupler 833528 12UR213 D/S Equal Junction - 45 833529 12UR236 D/S Junction (300 x 160) - 45 833530 12UR237 D/S Junction (300 x 150) - 45 833531 12UR239 D/S Slip Junction (300 x 150) - 45 838179 12UR240 D/S Junction (300 x 225) - 45 833532 12UR296 P/E Socket Plug 833534 - allows full bore access into the sewerage system for cleaning 12UR561 D/S Bend - 90 833536 12UR563 D/S Bend - 45 833537 12UR566 D/S Bend - 30 833541 12UR567 D/S Bend - 15 833543 12UR869 S/S Rocker Pipe 833546-600mm effective length

New Wavin Inspection Chambers Range Range 200 Inspection Chambers Supplier 24NE300 26NE300 20NE002 20NE015 Range 315 Inspection Chambers 34NE300 36NE300 Nom. Size 110mm 160mm 200mm 110mm 160mm Description D/S Equal Inspection Chamber Base 200mm dia. base with straight channel and single inlet. P/E Inspection Chamber Shaft 200mm dia. plain-ended shaft. Length: 2 metres. Square Cover & Frame A15 (Polypropylene) for non-trafficked/landscaped location. D/S Equal Inspection Chamber Base 315mm dia. base with straight channel and single inlet. NOW UPDATED FOR SfA7! Keyline 103735 297804 491873 103736 103737 103739 Range 315 Inspection Chambers cont. Supplier 34NE301 36NE301 34NE302 36NE302 34NE303 36NE303 30NE002 Nom. Size 110mm 160mm 110mm 160mm 110mm 160mm 315mm Description D/S Equal Inspection Chamber Base 315mm dia. base with straight channel And 2 inlets, inc. 45 left-hand equal branch inlet. D/S Equal Inspection Chamber Base 315mm dia. base with straight channel with 2 inlets, inc. 45 right-hand equal branch inlet. D/S Equal Inspection Chamber Base 315mm dia. base with straight channel with 3 inlets, inc. 2 x 45 equal branch inlets. P/E Inspection Chamber Shaft 315mm dia. plain-ended corrugated shaft. Length: 2 metres. Keyline 297806 297808 103738 103740 297807 297809 103741 30NE015 Square Cover & Frame 297810 A15 (Polypropylene) for non-trafficked/landscaped location. Civils and Drainage Solutions The Essential Guide Plastic Drainage 113

Civils and Drainage Solutions The Essential Guide Plastic Drainage 114 Range 500 Inspection Chambers Supplier Nom. Size 110mm Description D/S Equal Inspection Chamber Base 500mm dia. base with 110mm straight channel with 5 x 110mm inlets, inc. 2 x 45 and 2 x 90 branches.* Keyline Supplier Nom. Size Description Keyline 297812 50NE003 500mm P/E Inspection Chamber Shaft 103744 500mm dia. plain-ended shaft. Length: 3 metres. 54NE309 160mm D/S Unequal Inspection Chamber Base 500mm dia. base with 160mm straight channel with 1 x 160mm inlet and 4 x 110mm inlets, inc. 2 x 45 and 2 x 90 branches.* 182664 50NE930 500mm Restriction Access Cap 297813 Restricts access to 350mm. 54NE310 150mm D/S Unequal Inspection Chamber Base 500mm dia. base with 150mm straight channel with 1 x 150mm inlet and 4 x 110mm inlets, inc. 2 x 45 and 2 x 90 branches.* 491881 NOW UPDATED FOR SfA7! *Supplied with blank-off plugs for unused side entries.

Range 600 Inspection Chambers Supplier 66NE300 69NE300 612NE300 Nom. Size 150mm 225mm 300mm Description D/S Equal Inspection Chamber Base 600mm dia. base straight channel and single inlet. Keyline 630392 630414 630429 Supplier 66NE316 69NE316 612NE316 Nom. Size 150mm 225mm 300mm Description D/S Equal Inspection Chamber Base 600mm dia. base with straight channel and 3 inlets inc. 2 x 90 equal branch inlets. Keyline 630405 630426 630436 66NE314 69NE314 612NE314 150mm 225mm 300mm D/S Equal Inspection Chamber Base 600mm dia. base with bent 90 channel and single inlet. 630397 630417 630431 60NE003 600mm P/E Inspection Chamber Shaft 600mm dia. plain-ended shaft. Length: 3 metres. 102474 66NE315 69NE315 612NE315 150mm 225mm 300mm D/S Equal Inspection Chamber Base 600mm dia. base with bent 30 channel and single inlet. 630404 630421 630435 60NE930 600mm Restriction Access Cap Restricts access to 350mm. 630448 NOW UPDATED FOR SfA7! Accessories and spares are available for all ranges. Civils and Drainage Solutions The Essential Guide Plastic Drainage 115