Tandem subtly articulates the entry to the building. We were very pleased with the result.

Similar documents
SECTION ALUMINUM HANDRAIL SYSTEMS

STANDARD SHELTER SPECIFICATIONS ATTACHMENT A

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

Purchasing Department 530 Water Street Oakland, CA ADDENDUM No. 1. Bid No /03 LED Street Light Conversion Project

STREET LIGHTING GENERAL INFORMATION

March 3, Addendum No. 1

Modular CABANA Kit 16 x 16 (6x6) Lumber: Western Red CEDAR #1 (Cabinet) Shingles: 5X / 16" long / 1/2" thick or 16 oz. copper

D D TYPE A1, A2 & B MICHIGAN DEPARTMENT OF TRANSPORTATION 5-40 CONNECTION. L4" x 4" x 3/8" Brace. C8 x 4.25 Strut. WT9 x 17.5.

DIVISION 1100 TRAFFIC

ATI Evaluation Service A Division of Architectural Testing Certification Services

SPECIAL SPECIFICATION 8710 Decorative Pole Lighting Assembly

SECTION 1101 TRAFFIC SIGNALS AND APPURTENANCES END OF SECTION

SECTION DECORATIVE METAL FENCES AND GATES

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w

Aura FEATURES: SPECIFICATIONS: Illuminated Wooden Square and Rectangle Pendant STRUCTURA INC. FIXTURE TYPE: PROJECT NAME:

MATERIAL SPECIFICATION FOR STEEL POLES, BASE MOUNTED

SPECIFICATIONS: Architectural Aluminum Railings

SECTION AWNINGS

Sunground. pole Mount System MADE IN ONTARIO

Product Description. Standard Sizes and Hardware Locations

CITY OF KENOSHA PUBLIC WORKS DEPARTMENT- ENGINEERING LAKEFRONT LIGHTING PROJECT LIGHT POLES, LED LUMINAIRE FIXTURES & ARM HARDWARE NOTICE #17-18

SECTION DECORATIVE METAL RAILINGS

Call for any further details including but not limited to material, temper, thickness, paint and design.

SECTION ACCORDION FOLDING PARTITIONS

SECTION HVAC GRAVITY VENTILATORS

Scott Avenue Bridge Rehabilitation Scott Avenue over Des Moines River

markilux RS-2 More free space, opening up boundless possibilities INNOVATIONS 2017 rated to wind resistance class 3 (corresponds to Beaufort 6)

Optics Mounting Lamping Finish Voltage Options. T6 Metal Halide* H039T6 1 39wT6 H070T6 2 70wT6. H w H070 70w H w

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SPORTS AND STADIUM LIGHTING. Solutions for Amatuer and Professional Athletic Venues

ATI Evaluation Service A Division of Architectural Testing Certification Services

9B1101 Elite Referee Shelter. SECTION Benches 1.1 WORK INCLUDED

SPECIFICATION FOR TUBULAR STEEL LIGHTING COLUMN. Reference is made in this Specification to the following:

SECTION TURBINE VENTILATORS

SECTION PIER 94 HIGH MAST LIGHTING. A. Replace existing high mast lighting poles M and N located at Pier 94.

METALS Commissioning of Metals Structural Steel Framing Steel Studs... 2

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION PANEL AND POST AND PYLON SIGNAGE. 1. Non-illuminated Panel and Post signs. 2. Internal illumination Pylon (Cabinet and Post) signs.

Toll-Free

Code Compliance Research Report CCRR-0213

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SECTION ELECTRICAL POWER ATTIC EXHAUST VENTILATOR

Code Compliance Research Report CCRR-0213

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION ROOF ACCESSORIES

MAST ARMS: ALUMINUM, TRUSS TYPE AND DAVIT TYPE

Attachment A-Flagpole(s) Specifications

Door Hardware

Specifications for FL-100 Soffit Panel

SECTION DIRECTORIES

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION ROOF MOUNTED ATTIC EXHAUST VENT

Highways Square Trolley Pole. HSTP Range. Sales Direct: +44 (0) w: e: Highways Square Trolley Pole

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

SECTION SPORTS FIELD LIGHTING

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

Project: Type: Qty: Optics. Series. Reflector Mounting Lamping Finish Voltage Options BLC - S BLC-L 21 1 /4" 36 1 /4" 3 1 /2" O.D.

(d) Metal buildings used for industrial uses are not exempt from additional landscape standards as required in Section (e).

SECTION FLAGPOLES. 1.1 SUMMARY A. Section Includes: 1. Fixed high dimensional, ground set, uniform conical taper, seamless tube flag pole.

SECTION Metal Studs, Lath, Suspension Ceilings, Plaster, and Stucco Ceramic Tile.

SECTION WALL AND DOOR PROTECTION

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION ROOF ACCESSORIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

MCINTOSH COUNTY SCHOOLS TODD GRANT (K-5) SCHOOL DEMOLITION AND FINISHED SITE WORK

SECTION DETENTION WINDOW SCREENS. 1. Detention screens for interior and exterior installations at exterior windows in existing buildings.

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

Commercial Medical Marijuana Operation Design Guidelines

POLE: ANCHOR BASE, ALUMINUM, TAPERED TUBULAR SHAFT

Section A2 Table of Contents ALL GLASS ENTRANCES

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

SECTION 11 Architectural and Nonstructural Elements Field Investigation

Elegance & Bollards. 830 Series LED

SERIES VAP EXAMPLE: VAPRC2CL26TTTBKMV WATT CAT# APPLICATIONS FEATURES & BENEFITS SPECIFICATIONS ORDERING DATA

SECTION ORNAMENTAL ALUMINUM FENCING

Trex Commercial Products page Metal Railing

SECTION DOOR HARDWARE

SPECIFICATIONS Section Gable Walkway Covers

1. Include construction details, materials, individual components and profiles, and finishes.

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION METAL EQUIPMENT LOCKERS

SECTION ALUMINUM STORM WINDOWS

ARCHITECTURAL SPECIFICATIONS

TRACK RAIL. Base Shoe Railing System

SECTION PIPE AND TUBE RAILINGS

DIVISION 2 - SITE WORK

Code Compliance Research Report CCRR-0163

DIVISION 5 METALS COLD FORMED METAL FRAMING Structural Metal Stud Framing

SECTION ORNAMENTAL WELDED STEEL FENCING

Special Specification 6244 LED High Mast Illumination Assemblies

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Transcription:

Tandem subtly articulates the entry to the building. We were very pleased with the result. RACHEL PETRO RNL Lighting designer TANDEM National Renewable Energy Labs Golden, Colorado Architeture by RNL 24 2012 STRUCTURA INC. 2012 STRUCTURA INC. 25

ORTHO EVO TILT THREE PROFILES TO CHOOSE FROM Design by Clockwork Clockwork was founded by Christian Arnold and Neil Sommers in 2004 as a design studio concentrating on architecture, interior design, branding and industrial design. They have come to be known for adding unique industrial design elements to each space or product they create. Their rapid prototyping metal fabricating shop enhances the firm s ability to study nuanced details of a piece early on in the design process. 26 2012 STRUCTURA INC. 2012 STRUCTURA INC. 27

Standard Finishes: Custom Finish Examples: Wood Concrete Corten Weathering Steel Painted Aluminum Roano Zinc* River Current Zinc* Angel Hair Stainless * BASE OPTIONS Tandem is an exploration of contrast in form, color and texture. Site lighting can now respond to the surrounding architecture and site. Wood brings with it warmth and entices the senses. Natural variations in color and texture of concrete provide depth and blends perfectly into the landscape. Custom finishes like stainless steel, zinc, and weathering steel provide endless possibilities of light and shadow. These are a relief to the sterile finishes commonly seen in outdoor lighting and are only a sampling of what is possible with Tandem. * by Zahner Architectural Metals 28 2012 STRUCTURA INC. 2012 STRUCTURA INC. 29

24' A24-BP18 A24-BP B20-BP18 A16-BP18R 12' B12-BP A12-BP18R B12-BP A12-BP18 A12-BP ORTHO 24 EVO 13.5 EVO 24 TILT 17.5 TILT 21.5 ORTHO 12 Configured your way Configure Tandem to uniquely respond to your project s needs. Mount street side luminaires high allowing for greater distance between poles and better light distribution. Mount low-wattage pedestrian scale luminaires at lower heights to bring a more human scale to public spaces. 30 2012 STRUCTURA INC. 2012 STRUCTURA INC. 31

fixture mounting options BOLT PLATE MOUNTING OPTIONS Bolt plate is supplied pre-drilled per order for mounting of specified luminaires by others. MAST ARM MOUNTING OPTIONS 2 3/8 diameter mast arm for use when mounting luminaires with industry standard slipfitter adapters. Base detail standard with concealed anchor bolt mounting, aluminum cross ties and choice of panel material. SPECIFY 2 3/8 diameter x 4 BP-FLUSH MOUNT 4 MA-FLUSH MOUNT Single arm mounted between tandem pole. Specify the height of arm. (Luminaire by others.) SPECIFY 2 3/8 diameter x 4 BPR-FLUSH MOUNT WITH EXTENSION 4 MAR-FLUSH MOUNT WITH EXTENSION SPECIFY 2 3/8 diameter x 4 12 12 4 BP12-12 ARM MA12-12 ARM SPECIFY 2 3/8 diameter x 4 12 12 4 BP12R-12 ARM WITH EXTENSION MA12R-12 ARM WITH EXTENSION 32 2012 STRUCTURA INC. 2012 STRUCTURA INC. 33

Elevation Drawings 12 6 18 18 arm shown on side A with rear arm extension Fixture Side B No Fixture 2 x 4 -.125 or.25 Thick Aluminum Poles Pole Height Fixture Mounting Height Side panels (specify material and finish) 42 12 A Side B Side A Elevation Side Elevation B Elevation 34 2012 STRUCTURA INC. 2012 STRUCTURA INC. 35

How To Order HOW TO ORDER: Follow these steps below to order. Number designations match those found in the Ordering Guide. 6 1. Specify the product series. 2. Specify the overall pole height. This height is independent of the height of the highest luminaire. 3. Choose a powdercoat paint finish for pole. Custom colors are available. Indicate RAL color with the order or provide a paint chip for color match. 3,4 4. Determine required wall thickness. The total EPA of all fixtures must not exceed the maximum allowable EPA for the pole at the specified height and wind zone. See maximum wind load tables for allowable EPA. 5. Specify the mounting height of the A side luminaire. The A side luminaire is not required to be mounted at the top of the pole as shown in the drawing. Listed mounting heights are on a 4 module providing the best overall scale to the assembly. 6. Select the required A side luminaire mount. Choices include flush or arm mount options. Luminaires can be mounted using mast arm slip fitters or bolt plates. 8 5 2 7. Specify the mounting height of the B side luminaire similar to side A. 7 8. Specify the B side luminaire mount similar to side A. 9. Choose the base panel material. Consult the factory for use of other materials or panels. 10. Select any additional options, or special requirements. 1,9 11. Indicate MOD if the order requires any special mounting, electrical requirements, dimensions, custom finishes or other deviations from the product specification. A Side B Side 36 2012 STRUCTURA INC.

FIXTURE TYPE: PROJECT NAME: ORDERING GUIDE: EXAMPLE EVO-21.5-WHT-125-A20BP18R-B12MA-P2ALU-STD 1 2 3 4 5 6 7 8 9 10 11 1 Series Ortho Evo Tilt Ortho Evo Tilt 2 Pole Height 12 12' 13.5 13.5' 16 16' 17.5 17.5' 20 20' 21.5 21.5' 24 24' 25.5 25.5' A Side 5 Fixture Mounting Height A0 No fixture this side A12 12' A16 16' A20 20' A24 24' 6 Mounting Type (2) MA MAR MA18 MA18R 2 3/8" Diameter Mast Arms Flush Mount Flush Mount with 6" Rear Extension 18" Arm 18" Arm with 6" Rear Extension B Side 7 Fixture Mounting Height B0 No fixture this side B12 12' B16 16' B20 20' B24 24' 8 Mounting Type (2) MA MAR MA18 MA18R 2 3/8" Diameter Mast Arms Flush Mount Flush Mount with 6" Rear Extension 18" Arm 18" Arm with 6" Rear Extension 3 Pole Finish **** See color options on page 88 finishes tech sheet. CSM Custom Color 4 Wall Thickness (1) 125 0.125" wall 250 0.250" wall BP BPR BP18 BP18R Bolt Plates Flush Mount Flush Mount with 6" Rear Extension 18" Arm 18" Arm with 6"Rear Extension Bolt Plates BP Flush Mount BPR Flush Mount with 6" Rear Extension BP18 18" Arm BP18R 18" Arm with 6"Rear Extension 9 Panel Material P1 P2 CP (3) Wood (specify wood color) Aluminum (specify paint color) Custom Material (specify) (3) 10 Options DIN DUP Electrical DIN Rail Duplex Receptacle 11 Special STD MOD Standard Modified Footnote (1) Wall thickness determines the poles maximum wind loading per a given wind zone. See wind loading tables. (2) Leave this section blank if no fixture is on this side (3) See options on page 88-89 finishes tech sheet 2012 STRUCTURA INC. 37