Pioneer Forced Draft Cooling Tower Specifications

Similar documents
Pioneer Forced Draft Cooling Tower Specifications

TM Series Induced Draft Cooling Tower Specifications

PREMIER Low Profile Induced Draft Cooling Tower Specifications

DELTA. Cooling Towers, Inc. Delta Cooling Towers. Leader in Non-Corrosive Cooling Tower Technology

Fiberglass Cooling Towers

SECTION COOLING TOWER

FXV. Closed Circuit Cooling Towers. Closed Circuit Cooling Towers. Product Detail FXV - C 1. Engineering Data FXV Models... C2

VANGUARD Packed Column Air Stripping Tower Specifications

The following document can be provided to an Engineer, Contractor, or Owner to allow them to

The following document can be provided to an Engineer, Contractor, or Owner to allow them to properly specify MESAN s MXR-KM series Cooling Towers.

Lenntech. Tel Fax / Marley MS Cooling Tower /

IMT Open Cooling Towers... B78. Benefits... B80. Construction Details... B82. Custom Features and Options... B83. Accessories...

.2 Section Waste Management and Disposal..4 Section Vibration Isolation and Seismic Control Measures.

Water headers are made of reinforced plastic and the design of the spray tree ensures uniform water distribution.

TM Series Cooling Tower Specification

AMCOT COOLING TOWER CORPORATION LRC-H & LRC-LNS CROSS FLOW COOLING TOWER OPERATIONS AND MAINTAINENCE MANUAL

Central Station Air Handler Specification

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

SECTION FIELD ERECTED INDUCED DRAFT COOLING TOWER

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Diffused Aeration Piping Equipment

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

FXT Open Cooling Towers... B46. Benefits... B48. Construction Details... B49. Custom Features and Options... B50. Accessories...

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Cooling Tower Depot, Inc. 651 Corporate Circle, Suite 206 Golden, CO Phone (720) Fax: (720)

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

Pump Specifications 450 Series 1/2 hp Submersible Sump Pump

VANGUARD Packed Column Air Stripping Tower Specifications

13340 FIBERGLASS REINFORCED PLASTIC (FRP) ENCLOSURE

TEXAS DEPARTMENT OF TRANSPORTATION PROCUREMENT DIVISION TANK, POLYETHYLENE, ELLIPTICAL LEG, MINIMUM 1235 GALLON CAPACITY

ACF SERIES COUNTER FLOW COOLING TOWER ENGINEERING DATA

Series V Cooling Tower

Series 2900 Vinyl Single Hung Windows R50/R45/R35/R30 Performance for New Construction

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Pan System

SECTION PLUMBING DRAINAGE AND CONTAINMENT. Copyright Specialloy Industries Inc. dba Slot Drain Systems - All rights reserved

SUBMERSIBLE SEWAGE EJECTOR

NRM-7000 Guide Specifications

SECTION FUEL-FIRED UNIT HEATERS

SECTION EXHAUST FANS PART 1 GENERAL

TEXAS DEPARTMENT OF TRANSPORTATION GENERAL SERVICES DIVISION TANK, POLYETHYLENE, HORIZONTAL LEG, MINIMUM 500 GALLON CAPACITY PUBLICATION

SERIES COOLING TOWER 300, 400, 500 & 600 CLASS DIRTY WATER HIGH TEMPERATURE DURABILITY. Heavy Duty Crossflow Splash Filled Type

E. Fume hood to have set baffling system. No adjustable baffles allowed.

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

Compass Series Open Cooling Towers BAC AUSTRALIA

ENGINEERING SPECIFICATION PULTRUDED FIBERGLASS GRATING SAFE-T-SPAN HIGH LOAD CAPACITY (47% OPEN AREA) VINYL ESTER. January 24,

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Galvanized System

SECTION ORNAMENTAL WELDED STEEL FENCING

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

SST-II HYDRAULIC BI-FOLD SPECIFICATIONS

HYDROMATIC W/D/V-A1 SUBMERSIBLE SUMP/EFFLUENT

T-Series SPLIT SYSTEM UNITS TSA R-410A - 60 HZ

SECTION ROOF EDGE SAFETY RAILING SYSTEM

SUBMERSIBLE PUMPS FOR WASTEWATER (S-114)

SECTION DECORATIVE METAL RAILINGS

OXF-30K INDUCED DRAUGHT CROSSFLOW FRP COOLING TOWER

ENGINEERING SPECIFICATION

/ Marley Series 10 Series 15 Cooling Tower /

Specifications for FL-100 Soffit Panel

SECTION ALTERNATING TREAD STEEL STAIRS

LIT-058 ROOFGUARD-2017 The Uncloggable Roof Drain Dome Go to for the most current product specification sheets.

Architectural Roof and Wall Products Guide Specifications

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

VERTEX. different. Molded Fiberglass Composite Shelters

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

Testing. Test drainage products according to the applicable AASHTO or ASTM specification, except as otherwise noted.

Architectural Wall Products Guide Specifications

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

TYPES OF SEWAGE PUMPS. Solids Handling Pumps: Grinder Pumps: Effluent Pumps:

ENGINEERING SPECIFICATION. PULTRUDED PEDESTRIAN FIBERGLASS GRATING SAFE-T-SPAN T1210 VINYL ESTER and ISOPHTHALIC. October 25, 2004 Revision 1

The Uncloggable Roof Drain Dome LIT-058

SECTION METAL ROOF AND SOFFIT PANELS

Forced Draft Decarbonators. Degasification

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

SECTION PACKAGED, SUBMERSIBLE, DRAINAGE PUMP UNITS

ROOF DRAINS TABLE OF CONTENTS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION SHOWER AND DRESSING COMPARTMENTS

Aluminum Perforated Rolling Door

Flood Mitigation Solutions

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

N-SERIES: NTH2700 SPECIFICATIONS Tubular Composite Top Hung Sliding Door System

SD/SW/VS50 SD50 SW50 VS50

SECTION STEEL DOORS AND FRAMES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

DMS CONDUIT EFFECTIVE DATE: APRIL

SECTION PACKAGED, SUBMERSIBLE SEWERAGE PUMP UNITS

SAFE-TANK DOUBLE WALL TANKS HIGH DENSITY CROSSLINKED POLYETHYLENE STORAGE TANKS WITH OXIDATION RESISTANT LINING SYSTEM (NSF/ANSI 61)

B. System Design and Performance Requirements

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

HPGR200 2 HP. Capacity-U.S. G.P.M.

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

ENGINEERING SPECIFICATION FIBERTRED MOLDED STAIR TREADS SECTION 06610

special needs surface trajectory costs. High Efficiency 3. 4.

DIVISION 33 UTILITIES SECTION PACKAGED SEWAGE GRINDER PUMPING UNITS

DIVISION 22 PLUMBING SECTION INTERIOR SANITARY WASTE AND VENT PIPING SYSTEM

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Transcription:

Delta Cooling Towers, Inc. 41 Pine Street P.O. Box 315 Rockaway, New Jersey 07866-0315 Telephone 973.586.2201 Fax 973.586.2243 www.deltacooling.com sales@deltacooling.com Pioneer Forced Draft Cooling Tower Specifications Pioneer cooling towers are a forced draft counter-flow cooling tower with single module capacities from 10 to 100 cooling tons. These towers are a unique design that Delta Cooling Towers has been manufacturing since 1971 and have been very well received in both commercial and industrial applications. There are two overriding principles that make Pioneer cooling towers an excellent selection. The towers are corrosion-proof, not corrosion-protected, which is an important distinction of Delta towers. Cooling towers are outdoor equipment, either on roofs or sides of buildings, and are subjected to weather extremes continuously. Delta towers are manufactured in a seamless engineered plastic (HDPE) structural shell which is corrosion-proof and will not rust, chip, peel, crack or ever need painting or additional protective coatings. Comparably priced towers are often sheet metal with a galvanized coating. Zinc galvanizing provides only an interim protection against corrosion. This galvanizing wears away, often unevenly, exposing sheet metal to the rapid corrosive environment of cooling tower duty. The first engineered plastic cooling towers Delta shipped in 1971 show no signs of degradation in the structural shell today! The second principle of Delta towers is the engineering that led to a simplicity of design, translating into reliability and a trouble-free life of the towers. From the seamless cooling tower shell to the easy to maintain blower assembly, there are less overall components and systems within the tower to maintain. The towers are shipped factory complete with little more installation steps than hooking up the electrical and water. This design simplicity is recognized in many other industries as a key goal and leads to greater reliability and owner peace of mind. The Pioneer design has a tremendous track record for long-term durability and continues to be the choice for cooling tower application up to 100 cooling tons.

Delta Cooling Towers, Inc, Pioneer Forced Draft Cooling Tower Specifications, Page 2 of 5 PART 1 GENERAL 1.1 SCOPE PIONEER FORCED DRAFT COOLING TOWER Work included to furnish and install Delta Cooling Tower Model t cooling tower(s) consisting of all equipment necessary to provide a complete operating system to remove specified heat load. Cooling towers shall be packaged, factory pre-assembled to the fullest extent possible, forced draft, counter flow design 1.2 RELATED WORK {insert related work document here} 1.3 REFERENCES - STANDARDS AMCA - Air Moving and Conditioning Association ASTM - American Society for Testing and Materials ANSI - American National Standards Institute ASME - American Society of Mechanical Engineers 1.4 QUALIFICATIONS The cooling tower shall be manufactured by a company with at least 30 years experience manufacturer of seamless engineered polyethylene cooling tower systems. 1.5 WARRANTY Shell shall be warranted for 15 years and all other equipment shall be warranted for one year against material and workmanship defects from date of shipment. 1.6 SUBMITTALS Shop drawings shall be provided and shall include but not be limited to: A. System dimension B. Operating and dry weight C. Details of equipment D. Mounting and support requirements E. Descriptions and specifications PART 2 PRODUCT The cooling tower specified shall be factory assembled to the fullest extent possible.

Delta Cooling Towers, Inc, Pioneer Forced Draft Cooling Tower Specifications, Page 3 of 5 2.1 Forced Draft Cooling Tower, tons capacity, GPM, F hot water temperature, F cold water temperature, F wet bulb temperature A. Cooling tower 1. Shell shall be seamless, non-corrosive, hi-impact high density polyethylene (HDPE) of leak proof design. Shell wall shall exceed 1/4" average thickness. Structural shell shall be warranted for 15 years by the manufacturer. The structural shell shall be capable of withstanding water temperatures up to 180 F on a continual basis. 2. Sump shall be integral with cooling tower shell, creating a one-piece seamless structure. 3. Inspection port with removable HDPE cover located above the integral cold sump for accessibility to automatic make-up valve and adjustable float. 4. Fittings shall be non-corrosive polyvinyl chloride (PVC) bulkhead fittings with neoprene gaskets for inlet, outlet, drain, overflow and make-up (FPT) connections. 5. All outlet fittings for pump suction applications shall be provided with a vortex breaker. 6. Make up assembly, when incorporated in the sump of the cooling tower, shall be a mechanical valve assembly, adjustable height for varying operating conditions. The engineered plastic shell is the optimum material for cooling tower construction. The material is molded into a totally seamless shell which will never leak, unlike conventional cooling towers which require many panels, joints, seams, seam gaskets, caulking and hundreds of bolts or other fasteners to maintain the integrity of the product. The Delta structural shell will never rust, chip, crack or ever need painting or further protective coatings. The structural shell is warranted for 15 years which is much longer than other available cooling towers. Galvanized steel towers provide only interim corrosion protection. The zinc galvanizing is designed only to delay corrosion as the zinc wears steadily away. Moderately high temperatures and various water chemical treatments speed up this leaching of zinc into the water or atmosphere. With only ounces per square foot of corrosion protection, it is only a matter of time till corrosion of the underlying sheet steel sets in. Thin fiberglass panels can also not match the structural integrity of Deltas' seamless engineered plastic. Over time, if that long, leaks can develop at the joints even with gaskets and caulking applied. Thin fiberglass when exposed to the wide range of outdoor weather elements is also subject to delaminating, wicking and overall degradation

Delta Cooling Towers, Inc, Pioneer Forced Draft Cooling Tower Specifications, Page 4 of 5 B. Water distribution Totally enclosed, non-corrosive, polyvinyl chloride (PVC) spray tree with non-clog full cone spray nozzle distribution system. Threaded nozzle(s) shall be interchangeable and shall be capable of being substituted with a larger diameter orifice for increased flow conditions without increasing inlet pressure. C. Wet decking Spirally wound and bonded, one-piece, non-corrosive, polyvinyl chloride (PVC) wet decking. Non-corrosive, (PVC) hand straps secured to wet decking and drift eliminator sections for easy removal. D. Drift eliminator Drift eliminator shall be spirally wound and bonded, one-piece, non-corrosive, polyvinyl chloride (PVC) with non-corrosive PVC straps for easy removal for internal inspection and maintenance. E. Fan assembly 1. Forward curved centrifugal belt driven blower assembly, statically and dynamically balanced wheel, constructed of heavy duty, corrosionresistant steel with dipped and baked alkyd finish. 2. Motor shall be Totally Enclosed Fan Cooled suitable for 208 or 230/460 volt, 3 phase, 60 cycle operation. 3. Motor shall be warranted against defects in materials and workmanship for 5 years. F. Blower Hood 1. Blower hood shall completely enclose the blower, motor and rotating machinery to offer maximum protection to personnel. 2. Blower hood shall provide protection against rain and windblown debris entering blower inlet, also protect the motors and drives. 3. Blower hood shall be molded from high density polyethylene (HDPE) consistent with the tower shell. 4. Blower hood shall dampen sound of blower assembly by 3 dba at 5 feet.

Delta Cooling Towers, Inc, Pioneer Forced Draft Cooling Tower Specifications, Page 5 of 5 5. Hood inlets shall be covered with a PVC coated 3/8" #2 wire mesh screen fastened to the hood with stainless steel hardware. G. Hardware PART 3 EXECUTION All hardware shall be 304 Stainless Steel 1. GENERAL - INSTALLATION Installation of equipment shall conform to or be in compliance with the manufacturers recommendations. 2. TESTING A. Contractor shall perform all field testing and final adjustment of cooling tower equipment in accordance with provision of manufacturer B. Contractor shall certify that all operation criteria is within normal operating range as specified by the manufacturer. C. Should any part of the cooling tower equipment fail to meet any specified requirement, adjust, repair or replace any and all defects or inoperative parts immediately with manufacturers recommended parts or procedures.