PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA

Similar documents
SAFETY ON PUNCHING OF PRESTRESSED FLAT SLABS

Shear studs in slab-column connections with rectangular column

A NEW CFRP STRENGTHENING TECHNIQUE TO ENHANCE PUNCHING SHEAR STRENGTH OF RC SLAB-COLUMN CONNECTIONS

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

In-plane testing of precast concrete wall panels with grouted sleeve

CHAPTER 4 PUNCHING SHEAR BEHAVIOUR OF RECYCLED AGGREGATE CONCRETE TWO WAY SLABS

Punching shear resistance of reinforced concrete slabs under pneumatic loads

ADAPT-PTRC 2016 Getting Started Tutorial ADAPT-PT mode

ADAPT-PT 2010 Tutorial Idealization of Design Strip in ADAPT-PT

REVIEW ON SHEAR SLIP OF SHEAR KEYS IN BRIDGES

Experimental Investigation of the Fire Resistance of Thin Hollow-Core Concrete Slabs with Simple Supports

7.2 Transmission of Prestress (Part II)

Important note To cite this publication, please use the final published version (if applicable). Please check the document version above.

DESIGN OF VERTICAL SHEAR IN TRANSFER PLATES 1

Prestressed Concrete

ST7008 PRESTRESSED CONCRETE

Behavior and Strength of Slab-Edge Beam-Column Connections under Shear Force and Moment

ADAPT PT7 TUTORIAL FOR ONE-WAY SLAB 1

GFRP REINFORCED GFRC FOR THIN PERMANENT FORMWORK APPLICATIONS

SEISMIC RESPONSE OF LINEAR, FLANGED, AND CONFINED MASONRY SHEAR WALLS

SEISMIC PERFORMANCE OF POST TENSIONED INTERIOR SLAB-COLUMN CONNECTIONS WITH AND WITHOUT DROP PANEL

Seismic-Resistant Connections of Edge Columns with Prestressed Slabs

ON YIELD LINE ESTIMATES OF THE PUNCHING STRENGTH OF FULL PANEL UNBONDED POST-TENSIONED FLAT SLABS AT INTERNAL COLUMNS

TWO-WAY POST-TENSIONED SLABS WITH BONDED TENDONS

BS EN :2004 EN :2004 (E)

ANALYTICAL STUDY OF PUNCHING SHEAR ON WAFFLE SLAB WITH DIFFERENT RIB SIZES

RESILIENT INFRASTRUCTURE June 1 4, 2016

Structural Option April 7 th, 2010

CUREe-Kajima Flat Plate 1 Kang/Wallace

Contents. Foreword 1 Introduction 1

EXPERIMENTAL INVESTIGATION ON THE INTERACTION OF REINFORCED CONCRETE FRAMES WITH PRECAST-PRESTRESSED CONCRETE FLOOR SYSTEMS

Concrete Design Guide

Experimental investigation of reinforced concrete slabs with punching shear reinforcement

Research Article Flexural Behavior of Posttensioned Flat Plates Depending on Tendon Layout

CHAPTER 5 FINITE ELEMENT MODELLING

NON-LINEAR ANALYSIS OF RC FRAMES WITH MASONRY INFILLS SUBJECTED TO COLUMN FAILURE

GATE SOLVED PAPER - CE

SHEAR AND BUCKLING STRENGTHENING OF STEEL BRIDGE GIRDER USING SMALL-DIAMETER CFRP STRANDS

EXPERIMENTAL INVESTIGATION ON THE LOAD- CARRYING CAPACITY OF THIN WEBS INCLUDING POST-TENSIONING TENDONS

CYCLIC RESPONSE OF RC HOLLOW BOX BRIDGE COLUMNS STRENGTHENED USING CFRP AND RC JACKETING

Behavior of Skew Reinforced and Prestressed Concrete Composite Decks. Hany Ahmed Ahmed Dahish, Ahmed Foad El-ragi and Alaa Aly El-Sayed

PERFORMANCE STUDY OF RETROFITTED GRAVITY LOAD DESIGNED WALL FRAME STRUCTURES (SC-140)

Verification of Welded eaves moment connection of open sections

Technical Note Structural Concrete Software System

PUNCHING TESTS ON RC FLAT SLABS WITH ECCENTRIC LOADING

GUIDELINES FOR EXECUTION OF ADAPT-PT 1

Introduction 17/05/2015. How prestressing force transmitted to concrete?

OXFORD ENGINEERING COLLEGE (NAAC Accredited with B Grade) Department of Civil Engineering LIST OF QUESTIONS

CSU GUIDELINES. April 27, 2018 FOR POST-TENSIONED CONCRETE STRUCTURES.

Seismic behaviour of HSC beam-column joints with high-yield strength steel reinforcement

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

Load Transfer Test of Post-Tensioned Anchorage Zones in High Strength Concrete

Concrete shear keys in prefabricated bridges with dry deck joints

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

1. Cast-in-place concrete is specified in Section

Interface Shear Stress of Hollow Core Slabs with Concrete Toppings

Deformation Capacity of RC Structural Walls without Special Boundary Element Detailing

This final draft of the fib MC2010 has not been published; it is intended only for the purpose of voting by the General Assembly.

SEISMIC RETROFIT OF RC HOLLOW-SECTION PIERS WITH SHEAR FAILURE

Effect of Diagonal Belt to the Moment Capacity of the Precast Beam-Column Joint using CFRP Sheet

ADAPT PT7 TUTORIAL FOR BEAM FRAME 1

DESIGN FOR PROGRESSIVE COLLAPSE 1

PRECAST PRESTRESSED PORTAL FRAMES WITH CORRUGATED STEEL PANEL DAMPERS

Applications of sustainable post-tensioned concrete slabs

7.1 Transmission of Prestress (Part I)

HILTI HY 150 REBAR DESIGN GUIDE

Punching strength of R.C. Flat slabs with moment transfer

INFLUENCE OF PRSTRESS LEVEL ON SHEAR BEHAVIOR OF SEGMENTAL CONCRETE BEAMS WITH EXTERNAL TENDONS

Behaviour of UHPFRC-RC composite beams subjected to combined bending and shear

Guidelines for the Design of Post-Tensioned Floors

Progressive Collapse Mitigation in Flat-Slab Buildings

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

CANADIAN CODE IMPLEMENTATION IN 1 ADAPT SOFTWARE

RESILIENT INFRASTRUCTURE June 1 4, 2016

DESIGN OF STEEL FIBRE REINFORCED CONCRETE BEAMS USING THE NEW FIB MODEL CODE 2010 AN EVALUATIVE

Numerical and Experimental Behaviour of Moment Resisting Connections using Blind Bolts within CFSHS columns

Article publié par le Laboratoire de Construction en Béton de l'epfl. Paper published by the Structural Concrete Laboratory of EPFL

Performance based Displacement Limits for Reinforced Concrete Columns under Flexure

SHEAR OR BENDING? EXPERIMENTAL RESULTS ON LARGE T-SHAPED PRESTRESSED CONRETE BEAMS

Footings GENERAL CONSIDERATIONS 15.2 LOADS AND REACTIONS 15.4 MOMENT IN FOOTINGS

An Experiment on Tension Stiffening Effects of High Strength Concrete

DEVELOPMENT OF ANCHORAGE SYSTEM FOR CFRP SHEET IN STRENGTHENING OF REINFORCED CONCRETE STRUCTURES

PRESTRESSED CONCRETE STRUCTURES UNIT I INTRODUCTION THEORY AND BEHAVIOUR

SEISMIC RESPONSE OF END-CONFINED REINFORCED CONCRETE BLOCK SHEAR WALLS

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

ULTRA-HIGH PERFORMANCE PLASTER (UHPPl) FOR SEISMIC REINFORCEMENT OF MASONRY WALLS

Experimental study on the seismic performance of RC moment resisting frames with precast-prestressed floor units.

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

Effect of Torsion on Externally Prestressed Segmental Concrete Bridge with Shear Key

Shear Capacity of Self-Compacting Concrete Petra Van Itterbeeck 1, Niki Cauberg 2, Benoit Parmentier 3, Ann Van Gysel 4 and Lucie Vandewalle 5

Tests of R/C Beam-Column Joint with Variant Boundary Conditions and Irregular Details on Anchorage of Beam Bars

A Review on Seismic Assessment of Post- Tensioned Flat Slab

The nominal cover can be assessed as follows: C nom

Global Journal of Engineering Science and Research Management

LONG-TERM BEHAVIOUR COMPOSITE GIRDERS AND BEHAVIOUR UNDER SERVICE LOAD OF

Effect of web reinforcement on shear strength of shallow wide beams

Special Reinforced Concrete Structural Walls

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

composite elements, lateral loads, strain analysis, behavior Composite steel concrete elements made by steel and concrete are used in world wide almos

Transcription:

2011 PUNCHING RESEARCH AT UNIVERSIDADE NOVA DE LISBOA A. Ramos 1, V. Lúcio 2, D. Faria 3, M. Inácio 4 Abstract At the Civil Engineering Department of Universidade Nova de Lisboa punching research has been developed for several years. This paper reports the experimental analysis of reduced scale flat slab models under punching. The results of experimental tests on flat slabs without specific punching reinforcement, in prestressed flat slabs and in strengthened slabs using post-installed vertical steel bolts are presented. The experimental results are discussed and compared with EC2 (2004) and ACI 318-08 (2008) provisions. Results show that EC2 (2004) provisions provide good agreement with experimental results and that ACI 318-08 (2008) provisions result in safe estimates, although conservative, of punching loads. Keywords: punching, slabs, prestress, strengthening. 1 Introduction Flat slabs are widely used in many countries because of their economic and functional advantages. Although simple in appearance, a flat slab system presents a complex load bearing behaviour, especially in the slab-column connection. The punching resistance is an important subject in the design of flat slabs, frequently being the conditioning factor in choosing its thickness. This paper presents the results of various experimental investigations carried out at Universidade Nova de Lisboa regarding flat slabs without specific punching reinforcement, strengthened with vertical steel bolts and prestressed flat slabs.the increased use of this kind of slabs lead to the necessity of studying suitable strengthening methods associated to punching failure. So, experimental research was also developed regarding the study of two strengthening techniques related to punching, namely, strengthening using post-tensioning with anchorages by bonding and strengthening using post-installed vertical steel bolts, that can be applied for several reasons such as, e.g., construction or design errors, poor quality or inadequate materials, overloading and accidents. The strengthening method to be used in any particular situation depends on technical and economical factors, and may be a complex task. 1 Prof. Eng. PhD., Universidade Nova de Lisboa, Caparica, Portugal, ampr@fct.unl.pt 2 Prof. Eng. PhD., Universidade Nova de Lisboa, Caparica, Portugal, vjgl@fct.unl.pt 3 PhD. Student, Universidade Nova de Lisboa, Caparica, Portugal, duamvf@gmail.com 4 PhD. Student, Universidade Nova de Lisboa, Caparica, Portugal, mmgi@fct.unl.pt 125

2011 In this paper the experimental setups and materials used in the experimental research are described and punching loads are compared with EC2 (2004) [5] and ACI 318-08 (2008) [6] provisions regarding punching. 2 Models description 2.1 Models geometry The experimental work described in this paper consists basically in four different groups of reduced scale reinforced concrete flat slab models tested up to failure by punching. The first group consists in 6 slabs whose objective was to study the effect of compression due to prestress on punching load [1]; the second with 9 slabs whose objective was to study the effect of deviation forces from prestress on the punching load [2]; the third consisted of 7 strengthened slabs using post-tensioning with anchorages by bonding [3] and at last a forth group of 9 slabs used to study punching strengthening using post-installed vertical steel bolts [4,5]. In all these groups plain or reference slabs were tested in order to compare its results with the post-tensioned and the strengthened slabs. The dimensions of slabs AR and DF were 2300x2300 mm 2, some with 100 mm and others with 120 mm thickness, while slabs ID and MI were 1800x1800 mm 2 with 120 mm thickness. In all slabs, the punching load was applied by hydraulic jack positioned under the slab, through a steel plate with 200x200 mm 2 placed in center. Eight points on the top of the slab were connected to the strong floor of the laboratory using steel tendons and spreader beams (Fig. 1). 500 150 2300 Anchorage Load Cell "Column" Model 100 200 2300 Prestressing strand 200 500 Reaction slab 150 150 500 500 150 Hydraulic Jack Fig. 1 Model geometry (ex. Model AR2-reference slab) The models simulated the area near a column of an interior slab panel up to the zero moment lines. The bottom reinforcement consisted of 6 mm rebars every 200 mm in all slabs, in both orthogonal directions. In Tab. 1 is presented for each slab its depth (h), average effective depth (d) and top reinforcement ratio ( l ). To study the compression effect of prestress in punching behaviour Ramos [1] tested six slabs (AR2 to AR7) with variations of the levels of compression force applied in one or both orthogonal directions. The in-plane compression forces were applied to the slab edges by hydraulic jacks and external prestressing tendons on steel beams (Fig. 2). The internal in-plane forces were kept constant during the tests by using a load maintainer device connected to the hydraulic jacks. In slabs AR3 and AR4 the in-plane forces were applied only in one direction, and in the remaining slabs (AR5, AR6 and AR7) they were applied in both orthogonal directions. 126

2011 Fig. 2 System used to apply the in-plane force in slabs After the specimens were compressed the vertical load was incremented until failure, using the two hydraulic jacks positioned under the laboratory floor. The prestress in slabs AR used to study the effect of deviation forces (AR8 to AR16) consisted on four unbonded 12,7 mm diameter tendons, with a cross section area of 100 mm 2, in the two orthogonal directions. The prestressed tendons location can be seen in Fig. 3. 180 300 180 300 3x Models AR12 Models AR13 3 x Models AR8, AR10, AR11 e AR16 420 540 420 540 Models AR14 Models AR15 100 a Prestressing tendon (0.5") 150 140 720 280 720 140 150 horizontal parabolic linear parabolic linear parabolic horizontal Fig. 3 Prestress tendons location and profile (slabs AR slab for prestress deviation forces effect) In this second group of slabs the tendons profiles were trapezoidal, with the downward tendon deviation forces over the loaded area and the upward deviation forces at 127

11 2011 1000 mm from the centre of the loaded area (Fig. 3). The prestress vertical deviation (a) was 40 mm. Regarding the strengthened slabs using post-tensioning with anchorages by bonding, either with unidirectional or bidirectional prestress, the tendons profiles and location was the one presented in Fig. 4. Anchorage Load Cell Steel Beam Deviator Top End Strand Bottom End Fig. 4 Prestress profile and tendons location (slabs DF) With respect to the slabs strengthen with post-installed steel bolts, its positioning was the one presented in Fig. 5. The steel bolts used in slabs ID3, ID5, MI1 and MI3 were M6, in slabs ID4, MI2 and MI4 were M8 and in slab ID2 were M10. The bolts anchorage used in slabs ID were large and were placed on the concrete surface, while the slabs MI1 and MI2 have small bolts anchorage placed on the surface of the slab and slabs MI2 and MI3 have small bolts anchorage embedded in the concrete cover. P7 P5 P9 P6 P8 P10 P3 P4 P12 P11 P2 P16 P14 P1 P13 P15 Fig. 5 Post-installed steel bots (slabs ID and MI) 128

2011 2.2 Materials properties To assess the strength of the concrete used in the production of the test specimens, compression tests on cubes of 15x15x15cm 3 were carried out (f cm, cube ). The results are listed in Table 1. Tab. 1 Slabs properties Model h (mm) d (mm) l (%) f cm,cube (MPa) Reference Slabs AR2 100 80 1.6 48.9 AR9 100 82 1.6 46.4 DF1 100 69 1.9 31.0 DF4 120 88 1.2 24.7 ID1 120 87 1.2 49.2 Slabs for compression effect study AR3 100 80 1.6 46.8 AR4 100 80 1.6 53.9 AR5 100 80 1.6 44.6 AR6 100 80 1.6 46.2 AR7 100 80 1.6 54.8 Slabs for deviation forces effect study AR8 100 80 1.6 52.0 AR10 100 80 1.6 51.8 AR11 100 80 1.6 47.5 AR12 100 77 1.7 39.1 AR13 100 80 1.6 40.6 AR14 100 80 1.6 35.2 AR15 100 80 1.6 39.6 AR16 100 80 1.6 38.2 Slabs strengthened with post-tensioning DF2 100 67 2.0 33.0 DF3 100 67 2.0 31.5 DF5 120 85 1.2 26.0 DF6 120 85 1.3 26.3 DF7 120 89 1.2 27.0 Slabs strengthened with post-installed steel bolts ID2 120 94 1.3 52.3 ID3 120 90 1.2 59.6 ID4 120 90 1.2 59.7 ID5 120 94 1.1 59.8 MI1 120 91 1.2 45.4 MI2 120 94 1.1 48.4 MI3 120 91 1.0 33.5 MI4 120 91 1.0 33.5 129

2011 3 Experimental results and comparison with codes 3.1 EC2 (2004) provisions The resistance without punching shear reinforcement, using EC2 [6] was calculated with the following expression (Eqs. (1) to (4)): V 100 ρ f 1 3 k σ u d 0.18 k (1) cm 1 0,02 (2) y z cpy cpz cp (3) 2 d d z d (4) 2 y cp The limitation of the parameter k= 1 200 d in EC2 [6] to a maximum of 2 was neglected and k 1 =0.1. In the quantification of punching resistance the mean values for the compressive resistance of concrete were used and the partial safety coefficient was neglected. Reinforcement ratio values are calculated taking into account a slab width equal to the column width plus 3d for each side. Deviation forces are computed based on the work of Ramos [2], who proposed that their calculation should be based on the vertical components of prestress forces in the strands running within distances of 0.5d p from the column sides (d p is the prestress strand effective depth), so V eff =V exp -V dev, where V eff is the effective punching load, V exp is the experimental punching load and V dev is the deviation forces due to the prestress. Values considered for the cylinder compression strength (f cm ) were obtained with the relations presented in EC2 [6]. According to EC2 [6], the resistance with punching shear reinforcement was calculated using the lowest value obtained by following expressions (Eqs. (5) and (6)): 1 3 V 0.135 k 100 ρ f u d A f (5) cm sw sy,ef 1 3 * V 0.18 k 100 ρ f u d (6) cm Where A sw is the area of shear reinforcement inside the control perimeter u defined at 2d from the column faces,u * is the control perimeter defined at 2d from the outermost perimeter of shear reinforcement and f sy,ef is the effective strength of the punching shear 130

2011 reinforcement, according to f sy,ef = (250+0.25d) 1.15<f sy, and f sy is the yield strength of the steel bolts. 3.2 ACI 318-08 provisions For the calculation of the resistance without punching shear reinforcement and without any prestress effect, using ACI 318-08[7], the relevant expression for square columns, with side lengths less than 4d is Eq. (7): V = f cm u d 3 (7) The resistance capacity of flat slabs with punching shear reinforcement was given by the lowest value obtained by the following expressions (Eqs. (8) to (10)): fcm u d V = Asw f (8) sy 6 d V = 40 2 * u cm * f u d 12 (9) f V = u d cm * 3 (10) In prestressed slabs the following expression is used (Eq. (11)): V 0.29 f 0.3 u d V (11) cm cp dev According to ACI 318-08 [7], Eq. (7) is applicable when f ck 35 MPa (corresponding to an approximate value of f cm 43 MPa), with bidirectional prestress and when the average compressive stress in concrete in each direction due to prestress is between 0.9 MPa and 3.5 MPa. Though this expression is not strictly applicable to most of the models presented here, it was nevertheless used to estimate the ACI 318-08 [7] predicted punching load. Deviation forces are computed based on the vertical component of prestress forces crossing the control perimeter defined in ACI 318-08 [7], at a distance of 0.5d from the column perimeter. 131

2011 3.3 Experimental punching loads and comparison with code provisions Tab. 2 Reference and AR slabs results Model V exp (kn) Code V eff (kn) V (kn) V eff /V AR2 258 AR9 251 DF1 191 DF4 199 ID1 269 AR3 270 AR4 252 AR5 251 AR6 250 AR7 288 AR8 380 AR10 371 AR11 342 AR12 280 AR13 261 AR14 208 AR15 262 AR16 351 Reference Slabs EC2 258 270 0.96 ACI 318-08 258 187 1.38 EC2 251 273 0.92 ACI 318-08 251 187 1.34 EC2 191 203 0.94 ACI 318-08 191 138 1.38 EC2 199 217 0.92 ACI 318-08 199 168 1.18 EC2 269 270 1.00 ACI 318-08 269 209 1.29 Slabs for compression effect study EC2 270 288 0.96 ACI 318-08 270 186 1.45 EC2 252 312 0.84 ACI 318-08 252 212 1.19 EC2 251 306 0.86 ACI 318-08 251 210 1.20 EC2 250 308 0.85 ACI 318-08 250 211 1.18 EC2 288 340 0.90 ACI 318-08 288 247 1.17 Slabs for deviation forces effect study EC2 308 278 1.11 ACI 318-08 380 241 1.57 EC2 315 278 1.13 ACI 318-08 371 226 1.64 EC2 302 269 1.12 ACI 318-08 342 202 1.70 EC2 247 239 1.03 ACI 318-08 280 171 1.64 EC2 261 253 1.03 ACI 318-08 261 148 1.76 EC2 208 240 0.87 ACI 318-08 208 137 1.52 EC2 262 250 1.05 ACI 318-08 262 146 1.79 EC2 277 249 1.11 ACI 318-08 351 218 1.61 132

2011 Tab. 3 DF, ID and MI slabs results Model V exp (kn) Code V eff (kn) V (kn) V eff /V DF2 273 Slabs strengthened with post-tensioning EC2 212 207 1.02 ACI 318-08 273 192 1.42 DF3 255 EC2 192 204 0.94 ACI 318-08 255 190 1.34 DF5 295 EC2 215 222 0.97 ACI 318-08 295 237 1.25 DF6 293 EC2 208 220 0.95 ACI 318-08 293 240 1.22 DF7 320 EC2 235 235 1.00 ACI 318-08 320 256 1.25 Slabs strengthened with post-installed steel bolts ID2 406 EC2 406 392 1.03 ACI 318-08 406 315 1.29 ID3 331 EC2 331 305 1.08 ACI 318-08 331 231 1.43 ID4 381 EC2 381 365 1.04 ACI 318-08 381 357 1.07 ID5 366 EC2 366 374 0.98 ACI 318-08 366 364 1.01 MI1 329 EC2 329 289 1.14 ACI 318-08 329 247 1.33 MI2 352 EC2 352 359 0.98 ACI 318-08 352 364 0.97 MI3 274 EC2 274 264 1.04 ACI 318-08 274 232 1.18 MI4 273 EC2 273 322 0.85 ACI 318-08 273 288 0.95 4 Conclusions Based in the results presented before it may be stated that EC2 [6] is able to correctly predict punching loads. Otherwise the ACI 318-08 [7] is too conservative, as it seriously underestimates the punching resistance. The average relation V eff /V when using EC2 [6] was 0.95, 0.88, 1.06, 0.98 and 1.02 for reference slabs, for slabs used for the compression effect study, for slabs used for deviation forces effect study, for slabs strengthened with post-tensioning and for slabs strengthened with post-installed steel bolts, respectively, and so the values are near to the target value of 1.00. The corresponding relations V eff /V using ACI 318-08 [7] were 1.31, 1.24, 1.65, 1.30 and 1.15, respectively, results that are somewhat conservative. 133

2011 Acknowledgements This work received support from the Fundação para a Ciência e Tecnologia - Ministério da Ciência, Tecnologia e Ensino Superior through scholarship number SFRH/BD/37538/2007 and Project PTDC/ECM/114492/2009. We would also like to thank Concremat PréFabricação e Obras Gerais, S.A., HILTI Portugal and VSL Sistemas Portugal S.A.. References [1] Ramos, A. M. P., Lúcio, V. and Regan P., Punching of flat slabs with in-plane forces, Engineering Structures 33 (2011) 894 902. [2] Ramos, A. Punching in Prestressed Concrete Flat Slabs. PhD Thesis, Technical University of Lisbon, Lisbon, 2003. [3] Faria, D., Lúcio, V. and Pinho Ramos,A., Strengthening of flat slabs with posttensioning using anchorages by bonding, Engineering Structures 33 (2011) 2025 2043. [4] Inácio, M. Punching Shear Behaviour of Flat Slabs Strengthened With Steel Bolts Area and Position Anchorage Effect. MSc Thesis, Universidade Nova de Lisboa, Lisboa, 2010. [5] Duarte, I., A. M. P., Lúcio, V. J. G., Strengthening of Flat Slabs with Transverse Reinforcement, Proceedings of CCC2008 - Challenges of Civil Construction International Conference, Porto, 2008. [6] EN 1992-1-1:Design of Concrete Structures. Part 1-1: General rules and rules for buildings. Brussels, 2004. [7] American Concrete Institute: ACI 318-08. 2008. Building Code Requirements Structural Concrete and Commentary, ACI Committee 318. 134