ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Similar documents
LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

x act i Precision Pressure Transmitter for Food Industry, Pharmacy and Biotechnology Stainless Steel Sensor accuracy according to IEC 60770: 0.

Pressure transducers DMU 02 Vario (flush)

Field case for temperature transmitter Model TIF11

With uncoated stainless steel rope electrode and coated dynamic anchorage for level measurement of bulk-solid materials in higher silos.

Magnetic float switch For vertical installation Model FLS for nuclear power plants

CAPACITIVE LEVEL METERS CLM 36

Pressure Transmitter STK136,STK136Q

Capacitive level meter CLM 36

Pressure and temperature transmitters ATM/T

CombiTemp TCR6 Standard RTD temperature sensor

Level measurement CleverLevel LBFS Point level detection

CLM-36 MISURATORI CAPACITIVI IN CONTINUO CONTROLLI DI LIVELLO. Capacitive level meters CLM 36. Features of variants. Accessories

Level measurement CleverLevel LBFS Point level detection

Flow measurement of Liquids and Gases

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

KDS. All Metal Variable Area Flowmeter. for liquids and gases. Measuring range: l/h l/h water 5-50 Nl/h...

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

4-Beam-Turbidity Meter ITM-4

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

Diaphragm pressure gauge

SITRANS P measuring instruments for pressure

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Microlectra bv. Capacitive level meter CLM 36

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

Bypass Level Indicator / Functional description

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Type Type 2000 Transducers. I/P & E/P Transducers

High temperature pressure sensor

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

High Temperature Pressure Sensor

ENGLISH Datasheet Platinum Resistance Pt100 4 wire class B Resistance Thermometer with DIN B Head

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

SECTION PRESSURE AND DIFFERENTIAL PRESSURE GAUGES

Miniature I/P, E/P Transducer

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

LIQUID METER TYPE FMO

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Electromagnetic flowmeters. dg: NEW. Sensor MUT 2200 EL DS100-2-ENG 1/12

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Besides measurement of humidity and temperature EE30EX series calculate the values of the following physical quantities:

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Intrinsically Safe Industrial Measuring Probes for Humidity, Temperature, and Derived Variables

Diaphragm pressure gauge per EN 837-3,

P235S _ PIEZO-RESISTIVE PIEZOMETERS PIEZOMETERS

Expert SUBMERSIBLE LEVEL TRANSMÍTTERS BROCHURE US 2.75 EXPERT BROCHURE 1401

Electromagnetic Flange Type BTU METERS. eflow 800H SERIES. Size DN10 to DN1200 DESCRIPTION APPLICATION FEATURES

PK45I _ DRIVE-IN PIEZOMETERS PIEZOMETERS

Differential pressure

TSK S 3. Flap Flowmeter for liquids. Range: m 3 /h. Accuracy: ± 2.0 of reading. : PN 40, t max: C. p max

150 mm. 1/8 BSPP brass male compression fitting with locknut included

Level Switch. Series. instrumentation for fluids LC40. Instructions Manual

Platinum Resistance Pt100 Autoclave Drain Probe, 4 Wire Compatible with most common makes of Autoclaves

Flow Rate Transmitters/ Flow Switches

Mineral Insulated Platinum Resistance Thermometer PT100 Sensor - Available in 3mm or 6mm diameter x 150mm or 250mm probe lengths

Pt100 (100 0 C) to IEC 751, Class B, 4 wire 3.0, 4.0, 4.5 or 6.0mm diameter 316 stainless steel sheath.

Zirconia Oxygen Analyzer

Liquid level switch BW 17

Platinum Resistance Thermometer Pt100 Precision Probe - High accuracy platinum resistance thermometer probe, 6mm diameter x 250mm

SensoLyt System Design

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

ENGLISH Datasheet Platinum Resistance Pt1000 Class B Sensor with Teflon insulated lead

Datasheet Platinum Resistance Pt100 Dual Element Industrial Sensor Probe 6mm diameter x 150mm or 250mm probe lengths

Thermocouple for Flue Gas Temperature Measurements,

ELS LEVEL SWITCH ELS. ELS B10p, ELS B10x, ELS B101x ELS K01, ELS K02, ELS K03 ELS P01, ELS P03, ELS P04

Mechatronic pressure measurement. Applications. Special features. Description

QGO Oxygen Sensor. Building Technologies HVAC Products

Sensor unit MC2 for toxic gases and oxygen with analog output

PRODUCT RANGE CABLE GLANDS

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

Thermometer in stainless steel with capillary for mounting in thermowell or for direct mounting

CAPACITIVE LEVEL SENSORS DLS 27

Expert SUBMERSIBLE LEVEL TRANSMITTERS BROCHURE EN 2.75 EXPERT BROCHURE 1401

OM... Screw-Type Volumetric Flow Meter. for Viscous Media. Measuring ranges: l/min liquid

Temperature Measurement

TOPAS PMG / PMH Hydraulic sensor Hot water

Standard Bourdon tube pressure gauges EN 837-1

Load cell Pendeo Process and mounting kits

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Presented By. NicolScales.com Contact Us

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

CATALOG. Variable Area Flowmeter EASYFLOW SMART IN FLOW CONTROL.

VLM10 In-line Vortex Mass Flow Meter

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

D5100 Industrial Differential Pressure Transducer

Float Flow Meters series NF

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. SensyTemp TSHY (HY R-4E) Resistance thermometer for the food and beverage industries

VARIABLE AREA FLOWMETER EASYFLOW.

BM SERIES COMPACT GUIDE WAVE GUIDED WAVE RADAR LEVEL INSTRUMENTS

Transcription:

ILMK 8 Stainless Steel Probe Ceramic Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 % FSO Nominal pressure from 0... 40 cmh O up to 0... 00 mh O Output signals -wire: 4... 0 ma -wire: 0 0 V others on request Special characteristics diameter 9.5 mm especially for sewage, viscous and pasty media Optional versions IS-protection zone 0 mounting with stainless steel pipe flange version diaphragm 99.9 % AI O different kinds of cables different kinds of elastomers The stainless steel probe ILMK8 has been designed for continous level measurement in waste water, waste and higher viscosity media. Basic element is a robust and high overpressure capable capacitive ceramic sensor e.g. for low levels easily. Preferred areas of use are Water drinking water abstraction Sewage waste water treatment water recycling Fuel / Oil level monitoring in open tanks with low filling heights fuel storage tank farms / biogas plants D-656 Hohen Neuendorf / OT Bergfelde

Input pressure range Nominal pressure gauge [bar] 0.04 0.06 0. 0.6 0.5 0.4 0.6.6.5 4 6 0 6 0 Level [mh O] 0.4 0.6.6.5 4 6 0 6 5 40 60 00 60 00 Overpressure [bar] 4 4 6 6 8 8 5 5 5 5 5 45 45 Output signal / Supply Standard Option IS-protection -wire: 4... 0 ma / V S = 9... V DC -wire: 4... 0 ma / V S = 4... 8 V DC Option -wire -wire: 0... 0 V / V S =.5... V DC Performance Accuracy Permissible load Influence effects standard: ± 0.5 % FSO option: ± 0.5 % FSO R max = [(V S V S min) / 0.0 A] Ω supply: 0.05 % FSO / 0 V load: 0.05 % FSO / kω ± 0. % FSO / year at reference conditions 700 msec Long term stability Turn-on time Mean response time < 00 msec measuring rate 5/sec Max. response time 80 msec accuracy according to IEC 60770 limit point adjustment (non-linearity, hysteresis, repeatability) Thermal effects (Offset and Span) Thermal error ± 0. % FSO / 0 K in compensated range 0... 70 C Permissible temperatures Permissible temperatures medium: -5... 5 C electronics / environment: -5... 5 C storage: -5... 5 C Electrical protection Short-circuit protection permanent Reverse polarity protection no damage, but also no function Electromagnetic compatibility emission and immunity according to EN 66 additional external overvoltage protection unit in terminal box KL or KL with atmospheric pressure reference available on request Electrical connection (only for 4 0 ma / -wire) Cable with sheath material PVC (-5 70 C) grey PUR (-5 70 C) black FEP (-5 70 C) black TPE (-5 5 C) blue shielded cable with integrated air tube for atmospheric pressure reference Materials (media wetted) Housing stainless steel.4404 (6 L) Seals FKM FFKM EPDM others on request Diaphragm standard: ceramics Al O 96 % Option: ceramics Al O 99.9 % Nose cone POM Explosion protection Approval DX4-LMK 8 zone 0 4 : II G Ex ia IIB T4 Ga zone 0: II D Ex iad 0 T 85 C Safety technical maximum values U i = 8 V, I i = 9 ma, P i = 660 mw, C i = 7 nf, L i = 5 µh Permissible media temperature in zone 0: -0... 60 C with p atm 0.8 bar up to. bar zone and higher: -0... 70 C Connecting cables cable capacitance: signal line/shield also signal line/signal line: 60 pf/m (by factory) cable inductance: signal line/shield also signal line/signal line: µh/m 4 for optional stainless steel pipe following designation is valid: "II G Ex ia IIC T4 Ga" (zone 0) Miscellaneous Current consumption max. ma Weight approx. 400 g (without cable) Ingress protection IP 68 CE-conformity EMC Directive: 004/08/EC D-656 Hohen Neuendorf / OT Bergfelde

Wiring diagram -wire-system (current) -wire-system (voltage) p supply + A p supply + VS VS supply I supply U signal + V Pin configuration Electrical connection cable colours (DIN 4700) Supply + wh (white) Supply bn (brown) Signal + (only for -wire) gn (green) Shield gn/ye (green / yellow) Dimensions (in mm) LMK 8 standard LMK 8 with thread R" for stainless steel pipe LMK 8 flange version dimensions in mm dimensions DN5 / DN40/ DN50 / DN80 / PN6 D 5 50 65 00 k 85 0 5 60 d4 68 88 0 8 b 8 8 0 0 f n 4 4 4 8 d 4 8 8 8 D-656 Hohen Neuendorf / OT Bergfelde

Transmitter flange for flange version Technical data ILMK 8, ILMK 8H, ILMK 458, ILMK 458H Flange material stainless steel.4404 (6L) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / D = 5, k = 85, b = 8, n = 4, d= 4. kg DN50 / D = 65, k = 5, b = 0, n = 4, d= 8.6 kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4. kg Transmitter flange DN5 / ZFS540 Transmitter flange DN50 / ZFS5040 Transmitter flange DN80 / PN6 ZFS806 Mounting flange with cable gland Technical data all probes Flange material stainless steel.4404 (6L) Material of cable gland standard: brass, nickel plated on request: stainless steel.405 (0); plastic Seal insert material: TPE (ingress protection IP 68) Hole pattern according to DIN 507 Version Size (in mm) Weight DN5 / D = 5, k = 85, b = 8, n = 4, d= 4.4 kg DN50 / D = 65, k = 5, b = 0, n = 4, d= 8. kg DN80 / PN6 D = 00, k = 60, b = 0, n = 8, d= 8 4.8 kg DN5 / with cable gland brass, nickel plated ZMF540 DN50 / with cable gland brass, nickel plated ZMF5040 DN80 / PN6 with cable gland brass, nickel plated ZMF806 cable gland M6x.5 with seal insert (for cable- 4... mm) Terminal clamp Technical Data all probes with cable 5.5... 0.5 mm Material standard: steel, zinc plated optionally: stainless steel.40 (04) Weight approx. 60 g Terminal clamp, steel, zinc plated Terminal clamp, stainless steel.40 (04) Z0058 Z0057 D-656 Hohen Neuendorf / OT Bergfelde

ILMK 8 ILMK 8 - - - - - - - - - Pressure in bar in mh O 5 6 5 5 6 6 Input [mh O] [bar] 0.40 0.04 0 4 0 0 0.60 0.06 0 6 0 0.0 0.0 0 0 0.6 0.6 6 0 0.5 0.5 5 0 0 4.0 0.40 4 0 0 0 6.0 0.60 6 0 0 0 0.0 0 0 6.6 6 0 5.5 5 0 40 4.0 4 0 0 60 6.0 6 0 0 00 0 0 0 60 6 6 0 00 0 0 0 9 9 9 Housing Diaphragm C Output 4 0 ma / -wire 0 0 V / -wire Intrinsic safety 4 0 ma / -wire E Seals FKM EPDM FFKM 7 Electrical connection PVC-cable PUR-cable FEP-cable TPE-cable 4 Accuracy standard 0.5 % option 0.5 % Cable length in m standard: m PVC 0 0 standard: 5 m PVC 0 0 5 standard: 0 m PVC 0 0 standard: 5 m PVC 0 5 standard: 0 m PVC 0 0 special length PVC 9 9 9 Special version Stainless steel.4404 (6L) standard: m PUR 0 0 standard: 5 m PUR 0 0 5 standard: 0 m PUR 0 0 standard: 5 m PUR 0 5 standard: 0 m PUR 0 0 special length PUR 9 9 9 standard: 5 m FEP 0 0 5 standard: 0 m FEP 0 0 special length FEP 9 9 9 special length TPE 9 9 9 cable with integrated air tube for atmospheric pressure reference stainless steel pipe is not part of the supply Ceramics Al O 96% Ceramics Al O 99.9% standard prepared for mounting with stainless steel pipe flange version Standard lengths / 5 / 0 / 5 / 0 m are available from stock, special lengths are manufactured order-related, price per meter (see above). 0 0 0 5 0 5 0 9 9 0.06.0 This price list contains product specification; properties are not guaranteed. Detailed information about options are defined in the datasheet. Subject to change without notice. D-656 Hohen Neuendorf / OT Bergfelde