Thermal Remediation Services, Inc.

Similar documents
Thermal Remediation Services, Inc.

LOCKFORMER ELECTRIC RESISTIVE HEATING CASE STUDY

Design Considerations for Large Diameter Auger Soil Mixing with Steam and Zero- Valent Iron for Remediation of Chlorinated VOCs

Thermal Remediation Technology Overview and Practical Applications

Beyond Dig and Haul: A survey of Remedial Technologies. NYS Department of Environmental Conservation

In Situ Thermal Remediation and Principles of Electrical Resistance Heating (ERH)

LNAPL REMEDIATION USING ELECTRICAL RESISTANCE HEATING

Overview of In-Situ Thermal Remediation Technologies. Douglas Larson, Ph.D., P.E. Geosyntec Consultants, Inc. June 13-14, 2012

In Situ Thermal NAPL Remediation at the Northeast Site Pinellas Environmental Restoration Project

Remediation of TCE in Karst Bedrock

Rapid Site Remediation Electrical Resistance Heating

AIR-BASED REMEDIATION TECHNOLOGY SELECTION LOGIC. Air-Based Remediation Technologies

Alternative Cleanup Methods for Chlorinated VOCs

LIGHT HYDROCARBON RECOVERY USING A COMBINATION OF THERMAL AUGMENTATION AND BIOSLURPING

Site Profiles - View. General Information. Contaminants: Site Name and Location: Description: Historical activity that resulted in contamination.

2013 IPEC Conference San Antonio

New Advancements for In Situ Treatment Using Electrical Resistance Heating

Memorandum For: Ms. Lee Ann Smith, Chair, POWER Action Group Protecting Our Water and Environmental Resources

THERMAL REMEDIATION: TWO ERH CASE STUDIES

Multiphase Extraction (MPE):

Electrokinetic (EK) Enhanced Approaches for Remediation of Low Permeability and Heterogeneous Subsurface Materials

4 major challenges in the source zone!!! Source Zone Remediation with innovative Technologies. Very large reductions wanted/needed

Plume Cut-Off Treatment Example

Plume Area Treatment Example

IN SITU THERMAL REMEDIATION

In-situ Remediation Lessons Learned

Dr. Xiaosong Chen, PE

Lessons Learned from the Installation and Monitoring of a Permeable Reactive Barrier at the Lake City Army Ammunition Plant, Independence, MO

Site Profiles - View. General Information. Contaminants: Site Name and Location: Description: Historical activity that resulted in contamination.

FINAL Remedial Action Management Plan Work Plan

Comparison of EHC, EOS, and Solid Potassium Permanganate Pilot Studies for Reducing Residual TCE Contaminant Mass

THERMAL REMEDIATION OF A CLOSED GASOLINE SERVICE STATION PRESENTATION AND DISCUSSION LED BY: GLEN VALLANCE PROJECT MANAGER, CGRS

Case Studies: Overcoming Annoying Contaminant Rebound Using Adsorptive Technologies. RemTech Banff, AB October 11, 2018 Kevin French

Enhanced Anaerobic Bioremediation Using CAP18 as a Polishing Application for CVOC Impacted Groundwater

GTR Description Jenks Drive Corona, CA

Results from the LLNL Gasoline Spill Cleanup

Establishing Contact

Speaker Lowell Kessel GEO Incorporated - Gas Thermal Remediation Services

Low Temperature Volatilisation (LTV) Application

Use of In-Pile Thermal Desorption to Treat Persistent Organic Pollutants in Dredged Sediment

Biological Treatment of Residual DNAPL

Combining Thermal with Complimentary Technologies

Permeability Soils Six Years Post Injection. Innovation that Solves Complex Local Challenges, Worldwide. Copyright 2014 by CH2M HILL, Inc.

Soil Vapor Extraction O&M Report Camp Stanley Storage Activity, Texas

CHLORINATED SOLVENTS. The Value of Modified Active Gas Sampling in Assessing Remedial Options and Risk

COST AND PERFORMANCE REPORT

DYNAMIC UNDERGROUND STRIPPING AND HYDROUS PYROLYSIS/OXIDATION OF PCE AND TCE AT SAVANNAH RIVER SITE

EPA REGION 6 U.S. CONGRESSIONAL DISTRICT 4 AIR FORCE PLANT 4 FORT WORTH, TARRANT COUNTY, TEXAS. EPA ID# TXD Site ID:

PILOT TEST OF ELECTROKINETIC-ENHANCED BIOREMEDIATION OF PCE DNAPL

DESIGN PARAMETERS FOR MULTI-PHASE EXTRACTION SYSTEMS USING UNSATURATED AND SATURATED SOIL PROPERTIES

Permeable Reactive Barriers for Petroleum Hydrocarbons. Bruce Tunnicliffe Vertex Environmental Inc.

Conclusion on the supervision of the pilot test

Creamer Environmental. Containment, Caps & Liners. 12 Old Bridge Road C ed ar Grov e, N e w Jer s e y

2.0 BACKGROUND. 2.1 State of Practice for Off-Gas Treatment

IN SITU ANAEROBIC REDUCTIVE DECHLORINATION AT A FORMER AS/SVE SITE

September Prasad Kakarla, PE. In-Situ Oxidative Technologies, Inc. Lawrenceville, NJ

Site Profiles - View. General Information. Contaminants: Site Hydrology:

Enhanced In Situ Biodegradation of PCE Following Electrical Resistance Heating at a DNAPL Source Area

In Situ, Low Temperature Thermal Remediation of LNAPL with Pesticides and Other Recalcitrant Compounds

FACT FLASH. 5: Groundwater. What is groundwater? How does the ground store water? Fact Flash 5: Groundwater

In Situ Treatment of Contaminated Soil and Groundwater: Lessons Learned from the Field

Pump & Treat Remediation

Presented to the Norwalk Tank Farm Restoration Advisory Board. On behalf of KMEP. February 10, 2011

Enhanced Anaerobic Biodegradation of a Refinery Benzene Groundwater Plume

LNAPL Recovery Using Vacuum Enhanced Technology. Theresa Ferguson, R.G. June 2014

Electrokinetic-Enhanced Bioremediation ( EK BIO ) An Innovative Bioremediation Technology for Source Area with Low Permeability Materials

COKE OVEN AREA SPECIAL STUDY AREA INTERIM MEASURES WORK PLAN PHASE 1

Technology Presentation NEIWPCC (2016) Presenter: Noel Shenoi ( We support our men and women who have served our country

Permeable Reactive Barriers for Petroleum Hydrocarbons

In situ Remediation of 1,4-Dioxane using Electrical Resistance Heating

Large Scale Bioremediation Using Multiple Electron Donors

CRT CRT. Carus Remediation Technologies. Simplified Science. Carus Remediation Technologies. Carus Remediation Technologies

ORIN. Remediation Technologies. ORIN Remediation Technologies. Chemical Treatments. By: Larry Kinsman

Remedial Options to Excavation In-situ Remediation

Informational Meeting: Onsite and Offsite Response Action Plans

COST AND PERFORMANCE REPORT

Integrated DNAPL Site Strategy (IDSS)

Case Study Using Fenton s Reagent Under a Performance- Based Remediation Contract

Overview on in-situ thermal remediation technologies

FACTS ABOUT: Former GE Power Systems Apparatus Service Center (Voluntary Cleanup Program) Site Location

U. S. Army Corps of Engineers In Situ Air Sparging Subsurface Performance Checklist

Site Characterization Technologies for DNAPL Investigations

OPTIMIZATION OF A CHEMICAL OXIDATION TREATMENT TRAIN PROCESS FOR GROUNDWATER REMEDIATION. Gary Cronk, P.E., CHMM

Rhode Island Department of Environmental Mgmt. Office of Waste Management. NEWMOA TCE Vapor Intrusion Workshop Providence, Rhode Island April 13, 2015

CASE STUDY OF THE EFFECT OF REVERSE MATRIX DIFFUSION ON REMEDIAL TIME FRAME AT A SUPERFUND SITE

1,4-Dioxane Remediation Technology Development An Overview Based on 70+ Projects

Surfactant Enhanced Remediation Technologies and Case Studies. Dan Socci EthicalChem. SMART Remediation Ottawa, ON February 4, 2016

U. S. Army Corps of Engineers Soil Vapor Extraction Subsurface Performance Checklist

Parcel E (Site 03) Treatability Study and Parcel C Remedial Action

INNOVATIVE STRATEGY TO LOCATE VOC SOURCES DEEP IN THE SUBSURFACE

CASE STUDY COMPARISON OF MULTIPLE ACTIVATION METHODS FOR SODIUM PERSULFATE ISCO TREATMENT

Revitalization of a Contaminated Mall Using a Multi-Technology Approach

State of the Practice versus State of the Art in Chemical Oxidation / Reduction Technologies.

What is Ethylene Dibromide (EDB)?

Technologies. Sciences. Clichés 11/21/2017

LNAPL Remediation via Horizontal Biosparging Wells Facilitates Property Redevelopment

BOS 200 Remediation at a Iowa City Terminal Coralville, Iowa USA

Surfactant Enhanced Remediation Of Petroleum and Chlorinated Contaminated Sites. Bud Ivey Ivey International

Green Remediation of Petroleum Contaminated Groundwater Using Oxygen Injection in Western Maine

Unit Number Unit Name Unit Description Current Status SWMU 1 Hazardous Waste Storage Pad

Transcription:

Thermal Remediation Services, Inc. Electrical Resistance Heating for In-Situ Remediation of Soil & Groundwater December 10, 2002 Greg Beyke (770) 794-1168 gbeyke@thermalrs.com www.thermalrs.com 1 1

2 2 SOLVENT WATER TABLE SAND CLAY GROUNDWATER FLOW BEDROCK

3 3 PCU

4 4 GAC Filter

Why Electrical Resistance Heating?! Heating is uniform with no bypassed regions! Heating is rapid months vs. years! Steam is produced in-situ! Preferentially heats tight soil lenses and DNAPL hot spots! Cost effective: most commercial, fullscale sites range from $40-$100 per yds 3 5 5

Applications 6 6 Low permeability & heterogeneous lithologies DNAPL & LNAPL cleanups by aquifer and smear zone heating Heavy hydrocarbon mobilization Degradation enhancement (hydrolysis, bio) Remediation underneath operating facilities, in the presence of buried utilities and hazardous waste drums

In-Situ Steam Generation 7 7 ELECTRODE <15 V NEUTRAL ELECTRODE 150 V to 600 V HEATED ZONE 1. Soil grains act as electrical resistors 2. Steam generation is uniform through the heated zone 3. Discrete intervals can be heated

Surface Equipment 8 8 500 kw PCU Steam Condenser Photo Courtesy of Brown and Caldwell Operating Electrode

Vapor Recovery System 9 9 Water Storage Tank Or Sewer >99% of the contaminant mass remains in the vapor state Vacuum Pump Carbon or Catox Condenser 4 5 6 T T 3 2 1 ERH Power Control Unit

ERH Equipment Staging 10 10 Baker Tank 500 kw PCU Steam Condenser GAC Vessels Vacuum Blower CPVC pipe from wells

Full-Scale DNAPL Cleanup the Problem* 11 11 DNAPL (TCE & TCA) covering about 1 acre of an industrial site ENSR performed remediation for about 5 years and removed 30,000 pounds of TCE & TCA DNAPL remained in four areas, mostly under a large warehouse building Goal: Reach Tier III RBCA Cleanup Levels over entire site *Data from the 1999 EPA Cost and Performance Report

Full-Scale DNAPL Cleanup Site Map* 12 12 10 deep waste drain Semiconductor Building 107 electrodes Storm drain *Data from 1999 EPA Cost and Performance Report Cast iron roof drain DNAPL Power Control Unit TCE and TCA tanks

ERH Remediation Beneath a Building 13 13 Limited overhead access Vapor Recovery Pipe Photo Courtesy of Brown and Caldwell Electrode

Full-Scale DNAPL Cleanup Subsurface Cross-Section 14 14 Electrode SVE Well Electrode SVE Well Building Slab Fill 18 7 DNAPL Pools Silty Clay DNAPL Sandy Silt Heated Zone Clay Aquitard 20

Full-Scale DNAPL Cleanup Operations & Results* 15 15 Operations Heating (107 electrodes) started June 4, 1998 Aquifer reached boiling in 60 days Maintained above the boiling point of TCE (73ºC) for the next 3 months Results Tier III levels by late November 1998; the site is now closed >15,000 pounds of VOCs removed *Data from 1999 EPA Cost and Performance Report

Average Groundwater Concentrations Seven Most Contaminated Wells* 16 16 40,000 35,000 30,000 25,000 20,000 ug/l 15,000 10,000 *Data from 1999 EPA Cost and Performance Report March 1998 October 1998 November 1998 cis 1,2-DCE 98.3% 1,1,1-TCA TCE 99.9% 98.9% 5,000 0

Do Groundwater Concentrations Rebound after ERH Remediation? 17 17 4.0 3.5 3.0 2.5 mg/l 2.0 seven two wells decreased increased May-99 Dec-99 May-00 Average Additional Decrease = 23% 1.5 1.0 0.5 0.0 Data from ENSR report Aa6 Ba3 D3 D7 D9 E5 F9 F13 G3 ave Monitoring Wells

18 Polishing Mechanisms 18 Hydrolysis of Halogenated Alkanes Compounds such as TCA have a hydrolysis half-life of less than one day at steam temperatures. Iron Reductive Dehalogenation Steel shot used as electrode backfill provides an iron source for reductive dehalogenation (iron filing wall) Temperature Accelerates Reactions The above reaction rates are increased by factor of thousands at 100 C (Arrhenius Equation) Bioremediation by Thermophiles Thermophilic bacteria are the most effective solvent dehalogenators and prefer 40-70 C

Full Scale DNAPL Cleanup Cost & Performance Data* 19 19 Effectiveness Total operations took 18 weeks, five days Treated approximately 30,000 cubic yards Since completing, average groundwater VOC concentrations have continued to decrease Costs Total project costs were $32/cubic yard The total includes electrical costs of $6.50/cubic yard Vapor treatment was not required. If vapor treatment had been required, the cost would have been about $41 per cubic yard. *Data from the 1999 EPA Cost and Performance Report

TCE DNAPL Remediation Air Force Plant Four Fort Worth, Texas 20 20 Photo Courtesy of URS

ERH Remediation Beneath Air Force Plant Four 21 21 Photo Courtesy of URS electrical cable SVE piping electrode SVE well

Lowry Landfill System Layout 22 22 Electrode Field Thermal Oxidizers Cables to the Electrode Field 2000 kw PCU South Waste Pit