Inspection Report. Your Address. Prepared for: Sample Report Prepared by: Argosy Inspections 8244 SVL Box Victorville, CA 92395

Similar documents
Inspection Report. Prepared for: Tonia Mann. Property Address: 2557 Briar Valley Way Dacula, GA Date: March 01, 2012

Inspection Report. Prepared for: Gil Turiel. Property Address: 545 Briar Run Court Loganville, GA Date: July 17, 2011

New Jersey Home Inspection - Standards of Practice

COMPANY: CERTIFIED HOME INSPECTIONS ADDRESS: 92 NORTH RD. CITY, STATE, ZIP: NUTLEY NJ PHONE:

Alabama Home Inspections

All Pro Home Inspection. Home Report North Your Town

Pacific Inspection Group Keaau-Pahaoa Rd Keaau, Hawaii Somewhere In Paradise Keaau, Hawaii 96749

Home Inspection Report

Inspection Report. Prepared for: Yossi Berg. Property Address: 4925 Diggers Way Sugar Hill, GA. Date: July 20, 2011

Home Inspection Report

Home Inspection Report

Inspections Unlimited 12:38 August 20, 2013 Page 1 of 23 Sampleweb2013.pt6

Advanced Home Inspections

N.J.A.C. 13: NEW JERSEY ADMINISTRATIVE CODE Copyright (c) 2015 by the New Jersey Office of Administrative Law

Building Inspection Report

Madison's Home Inspections

SureHome Inspection Company. Home Inspection. Grant st Street Omaha, NE 68048

Weaver Home Inspections, LLC 181 Chase Rd. Columbus, Oh Home Inspection Report

Inspection Report. Property Address:

The Inspector. Property Inspection Report

Home Inspection Report. LH Home Services Edgewater McCall, Idaho

9) Home Inspection: As defined in Section 1-10 of the Act.

TITLE 68: PROFESSIONS AND OCCUPATIONS CHAPTER VIII: DEPARTMENT OF FINANCIAL AND PROFESSIONAL REGULATION

InterNACHI Home Inspection Report Checklist

Section Standards of Practice. a) The following are terms commonly used in the writing of home inspection reports.

1234 Main St. Buyer Name. Table of Contents

Home Inspection. Happy Home Buyer 125 Happy Lane Anytown TN The date of the inspection

The Standards of Practice

All Pro Home Inspection. Home Report South Your Town

Inspection Report. Prepared for: Tonia Mann. Property Address: 56 Riverview Place Douglasville, GA Date: September 19, 2012

SOUTH CAROLINA HOME INSPECTOR STANDARDS OF PRACTICE

Inspection Report. 1 of 8

REPORT CHECKLIST SUPPLEMENT

Property Inspection Report

TOWNSHIP OF LOGAN 125 MAIN STREET, PO BOX 314 BRIDGEPORT, NJ FAX

Inspection Report. Prepared for: Tonia Mann. Property Address: 1295 Greyland Hills Drive Lawrenceville, GA Date: April 24, 2012

FAIRA TRANSPARENCY REPORTS Robert Wayne Dr, Pasco, WA July 18 th, 2017

Hawks Eye Home Inspection LLC. Shoreline, Wa Williams Rd. Renton, Wa 98057

The Home Doctor, Inc.

Inspection Report. Prepared for: Yaron Sternberg. Property Address: 926 Hemingway Road Stone Mountain, GA. Date: April 15, 2011

Accurate Inspections Inc. Property Inspection Report

3D Home Improvement and Inspection Services, Inc

Property Inspection Report

SC Standards Of Practice for Home Inspectors

Home Inspection Report

A Summary of the Basic Duties of Maintenance, Repair and Replacement for CARRIAGE PARK CONDOMINIUM ASSOCIATION

GROUNDS Grading General Grading, slope and drainage: Satisfactory N/A See Notes. Grading and slope at house wall

PLYMOUTH CREEK HOME OWNERS ASSOCIATION

Home Inspection. 123 Main St Anywhere, USA Prepared for: Happy Homeowner Prepared by: Blue Crab Inspections

component was performing its intended function; installation and condition were appropriate for age and use.

1234 Main St Denver CO 80210

Home Condition Checklist

Thank you for your business!

2002 CAPHI (BC) Apartment Style Condominium Standards of Practice

ARIZONA. American Society of Home Inspectors. Arizona Chapter. Adopted by AZ ASHI Effective January 1, and

6954 Lakeside Dr. Property Inspection Report. - Provided by First Class Property Inspections, LLC -

a) For the purposes of this Section, the terms listed below shall mean:

Continuing Certificate of Occupancy Pre-Inspection Checklist

1st Defense Home Inspections, LLC

Walnut Creek Mutual Seventy

Work Write Up / Specification of Repairs HUD DIVISION 1. MASONRY HUD DIVISION 2. SIDING. Toll Free

Rental Inspection Checklist

Applecore Inspections, LLC

The following is the Standards of Practice (SOP) for Home Inspectors required by the state of Florida.

Inspection Services of the Treasure Coast

Property Inspection Report

Property Inspection Checklist

Friendly Inspection Services

Sample Inspection Report

J & M Solutions, LLC

ASHI STANDARD OF PRACTICE FOR HOME INSPECTIONS


HARPER WOODS BUILDING DEPARTMENT PROCEDURES FOR OBTAINING CERTIFICATE OF OCCUPANCY

Pre-Listing Home Inspection Checklist

1. Definitions and Scope. Robert Young's Montreal Home Inspection Services Inc STANDARDS OF CARE. Table of Contents

Exterior structures (fences, sheds, decks, retaining walls, detached garages) in good condition, no evidence of termite damage or rotted wood

HOME INSPECTION CHECKLIST

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

BELLA PALERMO HOMEOWNERS ASSOCIATION MAINTENANCE MATRIX DIVISION OF MAINTENANCE AND REPAIR RESPONSIBILITY

A UCC Building permit is not required for the exceptions listed below for COMMERCIAL application: (403.42): Building construction for the following:

Lacroix Home Inspection LLC th. NW Gig Harbor, WA 33e333. Inspection of. xxxxx 000St. NW Somewhere, oo

Inspect Hawaii. Property Inspection Report

Property Inspection Report

A Sample Report On The Conditions At:

WEST MICHIGAN HOME INSPECTORS LLC 3134 Chamberlain SE Grand Rapids MI

NEV-CAL Home Inspections

UP AND UP HOME INSPECTIONS

Repair or replace section of driveway, approach, or sidewalk that are a trip hazard.

Bill Ostoyic Building Inspection Report XXXXXXX XXXXX XXXXX, Fl. Licensed and Insured

,Home Inspection Report

SUMMARY 1234 Main St.Loudon TN Buyer Name 08/28/2018 9:00AM

Report Page 1 of 23 12/30/2013 Tri-City Home Inspections James Eddy ID:

Building Inspection Report

Friendly Inspection Services

Inspection Report. Provided by: Cummins Services LLC. Inspector: Bill Cummins. Phone:

HOME INSPECTOR MINIMUM STANDARDS OF PRACTICE. A. In this chapter, the following terms have the meaning indicated.

BUILDING INSPECTION DIVISION Vacant Property Notice Exterior & Interior Inspection Checklist

Mississippi Home Inspector Regulatory Board Standards of Practice and Code of Ethics

Total Home Inspection Checklist

Commercial Standards of Practice

Transcription:

Inspection Report Your Address Prepared for: Sample Report Prepared by: 8244 SVL Box Victorville, CA 92395

Page 1 of 33 Defective Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Plumbing 1. Backflow preventer: None present**** Missing backflow preventer, suggest install backflow preventer to prevent contaminants into the potable drinking water supply Electrical 2. South exterior Electric Panel 120 VAC Branch Circuits: Copper**** Double tapping at the breaker, can cause circuit to overheat, Evaluation by a licensed electrician is recommended 3. 4. 5. 6. 7. South exterior Electric Panel Manufacturer: Cutler-Hammer South exterior Electric Panel Main Breaker Size: 50 amps South exterior Electric Panel Breakers: Copper Door Bell: Hard wired C.O. Detector: Not present**** Recommend installing a C.O. detector for safety reasons Garage/Carport 8. Front of Home Garage Garage Door Pressure Reverse Working Not working**** Pressure switch does not work (SAFETY), recommend adjusting screws on motor

Page 2 of 33 Defective Summary (Continued) 9. Front of Home Garage Door to House Self Closing and Latching: No self closing hinges**** As per code,garage door needs self closing hinges, recommend handyman to repair 10. Front of Home Garage Electrical Outlets 120V non GFCI Protection**** Non GFCI Protection, recommend qualified contractor to evaluate and repair Kitchen 11. Main floor Kitchen Disposal: Insinkerator**** The disposal is leaking, A licensed plumber is recommended to evaluate and estimate repairs Bathroom 12. Master Bathroom Fixtures/Faucets/Traps: Single handle sink faucet(s) & PVC trap(s), Two handle tub/shower faucet**** Leaking &/ or dripping faucet, A licensed plumber is recommended to evaluate and estimate repairs

Page 3 of 33 Marginal Summary This summary is not the entire report. The complete report may include additional information of concern to the client. It is recommended that the client read the complete report. Exterior Surface and Components 1. Windows: Metal- double pane**** Front window trim loose, Repairs are needed by a qualified technician (Does not interfere with the integrity of the window) Roof 2. House & Garage Roof Surface Material: Concrete tile**** Cracked cement tile, recommend handyman to repair with silicon (east side) Bathroom 3. Master Bathroom Shower/Surround: Ceramic tile floor & surround**** Replace old caulking at the shower pan, Recommend caulking Fireplace/Wood Stove 4. Family Room Fireplace Fireplace Construction: Prefab**** Fireplace window foggy, sealed unit, A qualified contractor is recommended to evaluate and estimate repairs

Page 4 of 33 Fireplace/Wood Stove (Continued) Fireplace Construction: (continued) Air Conditioning 5. North exterior AC System Condensate Removal: PVC**** The primary drain pan is rusted, Keep drain termination open & clear

Page 5 of 33 Table of Contents Definitions 6 General Information 6 Pre Inspection Agreement 7 Receipt 9 Lots and Grounds 10 Structure 10 Exterior Surface and Components 10 Plumbing 11 Electrical 12 Roof 13 Attic 14 Garage/Carport 14 Kitchen 16 Laundry Room/Area 17 Bathroom 17 Bedroom 19 Living Space 20 Fireplace/Wood Stove 21 Air Conditioning 22 Heating System 23 Pool/ Spa 24 Maintenance Advice 24 Standards of Practice 26

Page 6 of 33 Definitions NOTE: All definitions listed below refer to the property or item listed as inspected on this report at the time of inspection Defective Item needs immediate repair or replacement. It is unable to perform its intended function. Acceptable Functional with no obvious signs of defect. Marginal Item is not fully functional and requires repair or servicing. Not Present Item not present or not found. Not Inspected Item was unable to be inspected for safety reasons or due to lack of power, inaccessible, or disconnected at time of inspection. General Information Property Information Client Name Sample Report Phone xxx-xxx-xxxx Fax E-Mail Your E-Mail Property Address XYZ Street City Rancho Cucamonga State CA Zip 12345 Client Information Inspection Company Inspector Name Paul Noe Company Name Inspector's Name Paul Noe Address 8244 SVL Box City Victorville State CA Zip 92395 Phone 888-699-8060 Fax E-Mail argosyinspections@gmail.com Realtor's Name Agents Name File Number 101813 Amount Received $500.00 Conditions Others Present Seller's Agent Property Occupied Vacant Estimated Age 10 years Entrance Faces East Inspection Date 10/17/2013 Electric On Yes Gas/Oil On Yes Water On Yes Temperature 55-60 degrees Weather Sunny Soil Conditions Dry Space Below Grade None Building Type Single family Garage Attached Sewage Disposal Public How Verified Multiple Listing Service Water Source City How Verified Multiple Listing Service CBS Code

Page 7 of 33 Pre Inspection Agreement On File Inspection Agreement Inspector Name Paul Noe Company Name 1. Address 8244 SVL Box 2. City Victorville State CA Zip 92395 Client Name: Sample Report Property Address: XYZ Street City State Zip Rancho Cucamonga, CA 12345 3. Inspection Agreement THIS AGREEMENT is made and entered into by and between, referred to as "Inspector", and referred to as "Client". In consideration of the promise and terms of this Agreement, the parties agree as follows: 1.The client will pay the fee as listed on the Receipt page & the General Information page, agreed upon by both parties for the inspection of the "Property", being the residence, and garage or carport, if applicable, located at the address shown above. 2.The Inspector will perform a visual inspection and prepare a written report of the apparent condition of the readily accessible installed systems and components of the property existing at the time of the inspection. Latent and concealed defects and deficiencies are excluded from the inspection. 3.The parties agree that the "Standards of Practice" (the "Standards") shall define the standard of duty and the conditions, limitations, and exclusions of the inspection and are incorporated by reference herein. A copy of the Standards is included with this report. If the state where the inspection is performed imposes more stringent standards or administrative rule, then those state standards shall define the standard of duty and the conditions, limitations and exclusions of the inspection. 4.The parties understand and agree that the Inspector and its employees and its agents assume no liability or responsibility for the costs of repairing or replacing any unreported defects or deficiencies either current or arising in the future or any property damage, consequential damage or bodily injury of any nature. If repairs or replacement is done without giving the Inspector the required notice, the Inspector will have no liability to the Client. The client further agrees that the Inspector is liable only up to the cost of the inspection. 5.The parties agree and understand the Inspector is not an insurer or guarantor against defects in the structure, items, components or systems inspected. INSPECTOR MAKES NO WARRANTY, EXPRESS OR IMPLIED, AS TO THE FITNESS FOR USE, CONDITION, PERFORMANCE OR ADEQUACY OF ANY INSPECTED STRUCTURE, ITEM, COMPONENT, OR SYSTEM. 6.If Client is married, Client represents that this obligation is a family obligation incurred in the interest of the family. 7.This Agreement, including the terms and conditions on the reverse side, represents the entire agreement between the parties and there are no other agreements either written or oral between them. This Agreement shall be amended only by written agreement signed by both parties. This Agreement shall be construed and enforced in accordance with the laws of the State of Arizona, and if that state's laws or regulations are more stringent than the forms of the agreement, the state law or rule shall govern. 8.Systems, items, and conditions which are not within the scope of the building inspection include, but are not limited to: radon, formaldehyde, lead paint, asbestos, toxic or flammable materials, molds, fungi, other environmental hazards; pest infestation; security and fire protection systems; household appliances; humidifiers; paint, wallpaper and other treatments to windows, interior walls, ceilings and floors; recreational equipment or facilities; underground storage tanks, energy efficiency measurements; concealed or private secured systems; water wells; heating systems accessories; solar heating systems; sprinkling systems; water softener; central vacuum systems, telephone, intercom or cable TV systems; antennae, lightning arrestors, trees or plants; governing codes, ordinances, statutes and covenants and manufacturer specifications. Client understands that these systems, items and conditions are accepted from this inspection. Any general

Page 8 of 33 Pre Inspection Agreement (Continued) comments about these systems, items and conditions of the written report are informal only and DO NOT represents an inspection. 9.The Inspection and report are performed and prepared for the sole and exclusive use and possession of the Client. No other person or entity may rely on the report issued pursuant to this Agreement. In the event that any person, not a party to this Agreement, makes any claim against Inspector, its employees or agents, arising out of the services performed by Inspector under this Agreement, the Client agrees to indemnify, defend and hold harmless Inspector from any and all damages, expenses, costs and attorney fees arising from such a claim. 10.The Inspection will not include an appraisal of the value or a survey. The written report is not a compliance inspection or certification for past or present governmental codes or regulations of any kind. 11.In the event of a claim by the Client that an installed system or component of the premises which was inspected by the Inspector was not in the condition reported by the Inspector, the Client agrees to notify the Inspector at least 72 hours prior to repairing or replacing such system or component. The Client further agrees that the Inspector is liable only if there has been a complete failure to follow the standards included in the report or State law. Furthermore, any legal action must be brought within two (2) years from the date of the inspection or will be deemed waived and forever barred. 12. In the event of a cancelation, a 24 hour notice must be given by phone call or email otherwise a fee of $150.00 will be applied. Client has read this entire Agreement and accepts and understands this Agreement as hereby acknowledged. Client acknowledges receipt of the standards of practice which applies. Signature: X Signature: X Buyer Present: [x] Yes [] No Agent present: [x] Yes [] No Client agrees to release reports to seller/buyer/realtor: [x] Yes Signature [ ] No Inspection Date: October 18th, 2013

Page 9 of 33 Receipt On File Receipt Inspector Name Paul Noe Company Name 1. Address 8244 SVL Box 2. City Victorville State CA Zip 92395 Method of Payment Paypal 3. Amount Received $500.00 Thank you for choosing to perform your Home Inspection. Home and Termite Inspection Receipt.

Page 10 of 33 Lots and Grounds Sheds, if present, are beyond the scope of the inspection & are excluded from the report. Landscape irrigation systems, if present, are beyond the scope of the inspection & were not tested. Any concerns with these systems should be brought up with the sellers, seller's agent or a qualified landscape contractor. 1. Acceptable Driveway: Concrete 2. Acceptable Walks: Concrete 3. Acceptable Front porch floor: Concrete 4. Acceptable Back patio floor: Concrete, Flagstone 5. Acceptable Fences: Block/ Brick, Metal 6. Acceptable Gates: Wood gate(s) 7. Acceptable Grading: Minor slope 8. Not Inspected Sprinklers Present (not checked) 9. Acceptable Vegetation: Shrubs 10. Acceptable Exterior Surface Drain: Surface drain 11. Acceptable Retaining Walls: Block 12. Acceptable Shed Plastic Structure 1. Acceptable 2. Acceptable 3. Acceptable 4. Acceptable 5. Acceptable 6. Acceptable 7. Acceptable 8. Acceptable Structure Type: Wood frame Foundation: Poured concrete slab Differential Movement: Cracks present, no signs of displacement Bearing Walls: Frame Joists/Trusses: Pre engineered Piers/Posts/Columns: Stucco Stairs/Handrails: Wood stairs with wood handrails Subfloor: Composite manufactured materials Exterior Surface and Components Whole House Exterior Surface 1. Acceptable Type: Stucco 2. Acceptable Trim: Wood 3. Acceptable Fascia: Wood 4. Acceptable Soffits: Wood 5. Acceptable Entry Doors: Wood with glass 6. Acceptable Patio Door: Sliding glass 7. Acceptable Deck/Patio/Porch Covers: Attatched to house 8. Acceptable Deck/ Balcony & Railing: Painted 9. Marginal Windows: Metal- double pane**** Front window trim loose, Repairs are needed by a qualified technician (Does not interfere with the integrity of the window)

Page 11 of 33 Exterior Surface and Components (Continued) Windows: (continued) 10. Low-E Coating? Yes 11. Acceptable Window Screens: Vinyl mesh Plumbing Landscape irrigation systems, if present, are beyond the scope of the inspection & were not tested. Any concerns with these systems should be brought up with the sellers, seller's agent or a qualified landscape contractor. Water softening systems, if present are beyond the scope of the inspection & was not inspected. Any concerns with this system should be directed to a qualified water treatment technician. Fire suppression sprinkler systems, if present, are beyond the scope of the inspection & were not tested. Any concerns with these systems should be brought up with a qualified fire sprinkler contractor 1. Acceptable 2. Acceptable 3. Acceptable 4. Acceptable 5. Defective Service Line: Copper Main Water Shutoff: Front of house Hose Bibs: Ball Water pressure: 80 lbs Backflow preventer: None present**** Missing backflow preventer, suggest install backflow preventer to prevent contaminants into the potable drinking water supply 6. Not Present Pressure Reducing Valve None present 7. Acceptable Functional Water Flow: Working'flowing 8. Acceptable Functional Drainage: Drains 9. Acceptable Sewer Cleanout: Front of house 10. Acceptable Water Lines: Copper 11. Acceptable Drain Pipes: ABS 12. Acceptable Vent Pipes: ABS 13. Acceptable Gas Meter: Front of house 14. Acceptable Main Gas Valve: Located at gas meter 15. Acceptable Gas Service Lines: Insulflex 16. Sprinkler system present Yes 17. Sprinkler alarm bell present Yes

Page 12 of 33 Plumbing (Continued) Garage Water Heater 18. Manufacturer: Bradford-White 19. Model Number: MI5036FBN Serial Number: GK14084542-394 20. Type: Natural gas Capacity: 50 Gal. 21. Approximate Age: 10 years Area Served: Whole House 22. Acceptable Water Heater Operation: Adequate 23. Acceptable Combustion Air/ Venalation: Double wall-metal 24. Acceptable Gas Water Heater Valve: located on flux line 25. Acceptable Flue Pipe: Double wall 26. Acceptable TPRV and Drain Tube: Copper 27. Water Softener Loop: Yes 28. Water Softener Present: No 29. ReCirculation Pump: No Electrical Low voltage systems such as phones, security systems, cable TV, satellite dishes & intercom systems are beyond the scope of the inspection & were not inspected. Any concerns with these systems should be brought up with the qualified individuals responsible for these systems. Low voltage landscape lighting systems, if present, are beyond the scope of the inspection & were not tested. Any concerns with these systems should be brought up with the sellers or seller's agent. 1. Service Size Amps: 200 Amps Volts: 120-240 Volts 2. Acceptable Service Feed/Underground/Electrical Mast: Underground utilities 3. Acceptable Service Conductor Type: Not visible 4. Acceptable Ground/ Bond: Gas and plumbing ground South exterior Electric Panel 5. Acceptable Manufacturer: Square D 6. Acceptable Panel Enclosure: Metal box & cover 7. Acceptable AFCI: Present 8. Acceptable GFCI: Present 9. Defective 120 VAC Branch Circuits: Copper**** Double tapping at the breaker, can cause circuit to overheat, Evaluation by a licensed electrician is recommended 10. Acceptable 240 VAC Branch Circuits: Copper and aluminum 11. Acceptable Branch Conductor Type: Romex 12. Adequate Clearance to Panel Yes South exterior Electric Panel 13. (Sub-Panel) Are the common & ground bars isolated? Yes 14. Defective Manufacturer: Cutler-Hammer

Page 13 of 33 Electrical (Continued) 15. Max Amp Capacity: 125 Amps 16. Defective Main Breaker Size: 50 amps 17. Defective Breakers: Copper 18. Not Present AFCI: Not Present 19. Not Present GFCI: Not present 20. Is the Panel Bonded? Yes 21. Defective Door Bell: Hard wired 22. Acceptable Exterior Lighting: Wall sconces, switched receptacle 23. Acceptable Exterior Electric Outlets: GFCI protected 24. Acceptable Exterior wiring: No issues 25. Acceptable Smoke Detector: Present**** Recommend replacing battery's in all smoke detectors. 26. Defective C.O. Detector: Not present**** Recommend installing a C.O. detector for safety reasons Roof House & Garage Roof Surface 1. Method of Inspection: On roof 2. Type: Hip 3. Approximate Age: 10 years 4. Acceptable Unable to Inspect: 0% 5. Marginal Material: Concrete tile**** Cracked cement tile, recommend handyman to repair with silicon (east side) 6. Acceptable Estimated Layers: One layer Patio Roof Surface 7. Method of Inspection: On roof 8. Acceptable Unable to Inspect: 0% 9. Acceptable Material: Rolled roof material 10. Type: Flat 11. Approximate Age: 10 years Patio, North Roof Surface 12. Method of Inspection: On roof 13. Acceptable Unable to Inspect: 0% 14. Acceptable Material: Rolled roof material, Coated 15. Type: Flat 16. Approximate Age: 10 years 17. Acceptable Ventilation: Soffit, O'Hagin 18. Acceptable Flashing: Galvanized 19. Acceptable Valleys: Preformed metal 20. Acceptable Skylights: Solar Tube 21. Acceptable Plumbing Vents: ABS

Page 14 of 33 Roof (Continued) 22. Acceptable Gas flue pipes: Double wall stainless steal 23. Not Present Gutters: None attached 24. Not Present Downspouts: None attached 25. Not Present Scuppers/ Roof Drains: None attached Southeast Chimney 26. Method of Inspection: On roof 27. Acceptable Chimney: Pre-fab 28. Acceptable Flue/Flue Cap: Metal 29. Acceptable Rain cap/spark arrestor: Present 30. Acceptable Chimney Flashing: Metal Attic Garage, Upstairs Attic 1. Method of Inspection: In the attic 2. Acceptable Unable to Inspect: 25% 3. Acceptable Walkway, work platform Present 4. Acceptable Roof Framing: Trusses 5. Acceptable Sheathing: OSB 6. Acceptable Insulation: Blown in 7. Acceptable Insulation Depth: 7-8" 8. Acceptable Approx. R-Value: R-38 9. Not Present Attic Fan: None 10. Acceptable Moisture Penetration: None visible 11. Acceptable Electrical Wiring Romex 12. Acceptable Plumbing Copper 13. Acceptable Bathroom Exhaust Ducts: Corrugated aluminum flex 14. Not Present Kitchen Exhaust Ducts: Metal 15. Not Present Dryer Exhaust Ducts: Metal 16. Fire Wall Between Units: Yes Garage/Carport Central vacuum system(s), if present, are beyond the scope of the inspection & are excluded from the report Front of Home Garage 1. Type of Structure: Attached Car Spaces: 2 2. Acceptable Garage Doors: Aluminum 3. Acceptable Door Operation: Mechanized 4. Acceptable Garage Door Pressure Reverse Working Working 5. Acceptable Garage Door Electric Eye Working Working 6. Acceptable Door to House Self Closing and Latching: Self closing hinges 7. Acceptable Firewall Entry Door Solid wood 8. Acceptable Service Doors: Wood 9. Acceptable Fire Wall/ Separation: Present 10. Acceptable Ceiling: Drywall 11. Acceptable Walls: Drywall 12. Acceptable Windows: Metal double pane 13. Acceptable Electrical Outlets 120V GFCI Protection 14. Acceptable Electrical Light Fixture Present and working

Page 15 of 33 Garage/Carport (Continued) 15. Acceptable Floor/Foundation: Poured concrete 16. Post Tension Slab: No Front of Home Garage 17. Type of Structure: Attached Car Spaces: 1 18. Acceptable Garage Doors: Aluminum 19. Acceptable Door Operation: Mechanized 20. Defective Garage Door Pressure Reverse Working Not working**** Pressure switch does not work (SAFETY), recommend adjusting screws on motor 21. Acceptable 22. Defective Garage Door Electric Eye Working Working Door to House Self Closing and Latching: No self closing hinges**** As per code,garage door needs self closing hinges, recommend handyman to repair 23. Acceptable 24. Acceptable 25. Acceptable 26. Acceptable 27. Acceptable 28. Acceptable 29. Defective Firewall Entry Door Solid wood Service Doors: Wood Fire Wall/ Separation: Present Ceiling: Drywall Walls: Drywall Windows: Metal double pane Electrical Outlets 120V non GFCI Protection**** Non GFCI Protection, recommend qualified contractor to evaluate and repair 30. Acceptable Electrical Light Fixture Present and working 31. Acceptable Floor/Foundation: Poured concrete 32. Post Tension Slab: No

Page 16 of 33 Kitchen Reverse osmosis units, if present, & their operation are beyond the scope of the inspection Main floor Kitchen 1. Acceptable Cooking Appliances: General Electric 2. Acceptable Anti-Tip Bracket Present 3. Acceptable Cooking Appliance Gas Valve Connected to the range 4. Acceptable Microwave: General Electric 5. Acceptable Microwave Ventilation Vented 6. Defective Disposal: Insinkerator**** The disposal is leaking, A licensed plumber is recommended to evaluate and estimate repairs 7. Air Gap Present: No 8. Acceptable Dishwasher: General Electric 9. Dishwasher Drain Looped High under Cabinet: Yes 10. Acceptable Refrigerator: General electric 11. Not Present Reverse Osmosis: Not present 12. Acceptable Plumbing/Fixtures: Single handle faucet & PVC trap 13. Acceptable Sink Stainless Steel 14. Functional Water Flow: Yes 15. Functional Drainage: Yes 16. Acceptable Counter Tops: Granite 17. Acceptable Electrical Outlets 120 Volts GFCI protected 18. Acceptable Electrical Lights Present and working 19. Acceptable Cabinets: Wood 20. Acceptable Ceiling: Drywall w/paint 21. Acceptable Walls: Decorative back splash 22. Acceptable Floor: Ceramic tile 23. Acceptable Windows: Metal double pane 24. Acceptable HVAC Source: Air exchange ventilation

Page 17 of 33 Laundry Room/Area Washer & dryer, if present & conveying, are beyond the scope of the inspection. Testing the appliances, if indicated, are done as a courtesy to the client. We recommend obtaining home warranty coverage for these appliances. Inside from garage Laundry Room/Area 1. Acceptable Ceiling: Drywall w/paint 2. Acceptable Walls: Drywall w/paint 3. Acceptable Floor: Ceramic tile 4. Acceptable Doors: Hollow wood, Solid wood 5. Acceptable Ventilation: Electric ventilation fan 6. Acceptable HVAC Source: Air exchange ventilation 7. Not Present Windows: None 8. Acceptable Electrical Outlets: 120v/240v Power 9. Acceptable Electrical Lighting Working 10. Acceptable Counter Tops: Laminate 11. Acceptable Cabinets: Wood 12. Acceptable Laundry Tub: Plastic 13. Acceptable Plumbing/Fixtures: Single handle faucet & PVC trap 14. Functional Water Flow: Yes 15. Functional Drainage: Yes 16. Washer/Dryer Tested: Yes 17. Washer/Dryer Operation Functional: Yes 18. Acceptable Washer Hose Bib: Ball valves 19. Acceptable Dryer Vent: Rigid metal 20. Acceptable Dryer gas valve: Ball valve 21. Acceptable Washer Drain: Wall mounted drain Bathroom Master Bathroom 1. Acceptable Closet: Walk In 2. Acceptable Ceiling: Drywall w/paint 3. Acceptable Walls: Drywall w/paint 4. Acceptable Floor: Ceramic tile 5. Acceptable Doors: Hollow wood 6. Acceptable Windows: Metal double pane 7. Acceptable Safety Glass Stamped on glass 8. Marginal Shower/Surround: Ceramic tile floor & surround**** Replace old caulking at the shower pan, Recommend caulking

Page 18 of 33 Bathroom (Continued) 9. Acceptable 10. Acceptable 11. Acceptable 12. Acceptable 13. Acceptable 14. Acceptable 15. Defective Spa/Tub/Surround: Fiberglass tub Electrical Outlets: 120 Volts GFCI protected Electrical Lighting Working Counter/Cabinet: Wood, Ceramic tile Sink/Basin: Molded single bowel Medicine Cabinet: Recessed mirror front Fixtures/Faucets/Traps: Single handle sink faucet(s) & PVC trap(s), Two handle tub/shower faucet**** Leaking &/ or dripping faucet, A licensed plumber is recommended to evaluate and estimate repairs 16. Acceptable Shut Off Valves Ball type 17. Acceptable Toilet Flushes Mechanism works 18. Acceptable Toilets Secured to Floor Bolted to the floor 19. Acceptable HVAC Source: Air exchange ventilation 20. Acceptable Ventilation: Electric ventilation fan 21. Functional Water Flow: Yes 22. Functional Drainage: Yes 2nd floor, Main hall bath Bathroom 23. Acceptable Ceiling: Drywall w/paint 24. Acceptable Walls: Drywall w/paint 25. Acceptable Floor: Ceramic tile 26. Acceptable Doors: Hollow wood 27. Acceptable Windows: Metal double pane 28. Acceptable Safety Glass Stamped on glass 29. Acceptable Shower/Surround: Fiberglass pan, Fiberglass surround 30. Acceptable Electrical Outlets: 120 Volts GFCI protected 31. Acceptable Electrical Lighting Working 32. Acceptable Counter/Cabinet: Wood, Ceramic tile 33. Acceptable Sink/Basin: Molded duel bowel 34. Acceptable Medicine Cabinet: Recessed mirror front 35. Acceptable Fixtures/Faucets/Traps: Single handle sink faucet(s) & PVC trap(s) 36. Acceptable Shut Off Valves Ball type 37. Acceptable Toilet Flushes Mechanism works 38. Acceptable Toilets Secured to Floor Bolted to the floor 39. Acceptable HVAC Source: Air exchange ventilation 40. Acceptable Ventilation: Electric ventilation fan 41. Functional Water Flow: Yes 42. Functional Drainage: Yes 1st floor, Main hall bath Bathroom 43. Acceptable Ceiling: Drywall w/paint 44. Acceptable Walls: Drywall w/paint 45. Acceptable Floor: Ceramic tile

Page 19 of 33 Bathroom (Continued) 46. Acceptable Doors: Hollow wood 47. Acceptable Windows: Metal double pane 48. Acceptable Shower/Surround: Fiberglass pan, Ceramic tile surround 49. Acceptable Electrical Outlets: 120 Volts GFCI protected 50. Acceptable Electrical Lighting Working 51. Acceptable Counter/Cabinet: Wood, Ceramic tile 52. Acceptable Sink/Basin: Molded single bowel 53. Acceptable Medicine Cabinet: Recessed mirror front 54. Acceptable Fixtures/Faucets/Traps: Single handle sink faucet(s) & PVC trap(s) 55. Acceptable Shut Off Valves Ball type 56. Acceptable Toilet Flushes Mechanism works 57. Acceptable Toilets Secured to Floor Bolted to the floor 58. Acceptable HVAC Source: Air exchange ventilation 59. Acceptable Ventilation: Electric ventilation fan 60. Functional Water Flow: Yes 61. Functional Drainage: Yes Bedroom Shades & window treatments, if present, are beyond the scope of the inspection & are excluded from the report Master Bedroom 1. Acceptable Ceiling: Drywall w/paint 2. Acceptable Walls: Drywall w/paint 3. Acceptable Floor: Carpet 4. Acceptable Doors: Hollow wood, slidding glass 5. Acceptable Windows: Metal double pane 6. Acceptable Electrical Outlets 120 Volts 7. Acceptable Electrical Lights Ceiling fan, switched receptical 8. Acceptable HVAC Source: Air exchange ventilation 9. Acceptable Smoke Detector: Present 10. Bedroom Egress Restricted: No 2nd Floor, West Bedroom 11. Acceptable Closet: Single 12. Acceptable Ceiling: Drywall w/paint 13. Acceptable Walls: Drywall w/paint 14. Acceptable Floor: Carpet 15. Acceptable Doors: Hollow wood 16. Acceptable Windows: Metal double pane 17. Acceptable Electrical Outlets 120 Volts 18. Acceptable Electrical Lights Ceiling fan, switched receptical 19. Acceptable HVAC Source: Air exchange ventilation 20. Acceptable Smoke Detector: Present 21. Bedroom Egress Restricted: No 2nd Floor, Southeast Bedroom 22. Acceptable Closet: Single 23. Acceptable Ceiling: Drywall w/paint 24. Acceptable Walls: Drywall w/paint 25. Acceptable Floor: Carpet 26. Acceptable Doors: Hollow wood

Page 20 of 33 Bedroom (Continued) 27. Acceptable Windows: Metal double pane 28. Acceptable Electrical Outlets 120 Volts 29. Acceptable Electrical Lights Ceiling fan, switched receptical 30. Acceptable HVAC Source: Air exchange ventilation 31. Acceptable Smoke Detector: Present 32. Bedroom Egress Restricted: No 2nd Floor, East Bedroom 33. Acceptable Closet: Single 34. Acceptable Ceiling: Drywall w/paint 35. Acceptable Walls: Drywall w/paint 36. Acceptable Floor: Carpet 37. Acceptable Doors: Hollow wood 38. Acceptable Windows: Metal double pane 39. Acceptable Electrical Outlets 120 Volts 40. Acceptable Electrical Lights Ceiling fan, switched receptical 41. Acceptable HVAC Source: Air exchange ventilation 42. Acceptable Smoke Detector: Present 43. Bedroom Egress Restricted: No Living Space Shades & window treatments, if present, are beyond the scope of the inspection & are excluded from the report Office, Study Nook Living Space 1. Acceptable Ceiling: Drywall w/paint 2. Acceptable Walls: Drywall w/paint 3. Acceptable Floor: Carpet 4. Acceptable Windows: Metal double pane 5. Acceptable Electrical Outlets 120 Volts 6. Acceptable Electrical Lights Ceiling fan 7. Acceptable HVAC Source: Air exchange ventilation 8. Acceptable Smoke Detector: Present Family Room Living Space 9. Acceptable Ceiling: Drywall w/paint 10. Acceptable Walls: Drywall w/paint 11. Acceptable Floor: Carpet 12. Acceptable Windows: Metal double pane 13. Acceptable Electrical Outlets 120 Volts 14. Acceptable Electrical Lights Ceiling fan, switched receptical 15. Acceptable HVAC Source: Air exchange ventilation 16. Acceptable Smoke Detector: Not Present Living Room Living Space 17. Acceptable Ceiling: Drywall w/paint 18. Acceptable Walls: Drywall w/paint 19. Acceptable Floor: Carpet 20. Acceptable Windows: Metal double pane 21. Acceptable Electrical Outlets 120 Volts 22. Acceptable Electrical Lights Ceiling fan, switched receptical 23. Acceptable HVAC Source: Air exchange ventilation 24. Acceptable Smoke Detector: Not Present

Page 21 of 33 Living Space (Continued) Formal dinning room Living Space 25. Acceptable Ceiling: Drywall w/paint 26. Acceptable Walls: Drywall w/paint 27. Acceptable Floor: Ceramic tile 28. Acceptable Windows: Metal double pane 29. Acceptable Electrical Outlets 120 Volts 30. Acceptable Electrical Lights Working 31. Acceptable HVAC Source: Air exchange ventilation 32. Not Present Smoke Detector: Not Present Fireplace/Wood Stove Fireplace operation, including gas logs & wood burning fireplaces are not operated at the time of the inspection & are beyond the scope of the inspection. Any concerns with these systems should be taken up with a qualified technician Family Room Fireplace 1. Type: Gas log 2. Marginal Fireplace Construction: Prefab**** Fireplace window foggy, sealed unit, A qualified contractor is recommended to evaluate and estimate repairs 3. Acceptable Smoke Chamber: Metal 4. Acceptable Flue: Metal 5. Acceptable Damper: Metal 6. Acceptable Hearth: Flush mounted 7. Acceptable Mantle Wood 8. Damper Modified for Gas: Yes

Page 22 of 33 Air Conditioning Window A/C units, if present, are beyond the scope of the inspection & excluded from this inspection. Any concerns with the unit(s) should be brought up with a qualified technician North exterior AC System 1. Acceptable Exterior Unit: Pad mounted 2. Not Inspected A/C System Operation: Not inspected**** To avoid possible compressor damage due to outside temperature below 60 degrees, the unit was not tested. 3. Marginal Condensate Removal: PVC**** The primary drain pan is rusted, Keep drain termination open & clear 4. Manufacturer: Goodman 5. Model Number: CLJ48-1 Serial Number: 0211416416 6. Area Served: Upstairs Approximate Age: 10 years 7. Type: Central A/C Capacity: 4 Ton 8. Acceptable Fuel type: 240 volt electric 9. Acceptable Visible Coil: Aluminum 10. Acceptable Refrigerant Lines: Low pressure and high pressure 11. Acceptable Electrical Disconnect: Non-fused disconnect 12. Max fuse: 50 amps 13. Acceptable Fuses/ breaker installed: 55 amps 14. RA: SA: 15. Split: North exterior AC System 16. Acceptable Exterior Unit: Pad mounted 17. Not Inspected A/C System Operation: Not inspected**** To avoid possible compressor damage due to outside temperature below 60 degrees, the unit was not tested. 18. Acceptable Condensate Removal: PVC 19. Manufacturer: Goodman 20. Model Number: CLJ48-1 Serial Number: 0211416418 21. Area Served: Downstairs Approximate Age: 10 years 22. Type: Central A/C Capacity: 4 Ton 23. Acceptable Fuel type: 240 volt electric 24. Acceptable Visible Coil: Aluminum 25. Acceptable Refrigerant Lines: Low pressure and high pressure 26. Acceptable Electrical Disconnect: Non-fused disconnect 27. Max fuse: 50 amps 28. Acceptable Fuses/ breaker installed: 50 amps 29. RA: SA: 30. Split:

Page 23 of 33 Heating System Attic Heating System 1. Acceptable Heating System Operation: Adequate 2. Manufacturer: Goodman 3. Model Number: GMTH115-5 Serial Number: 0207607759 4. Type: Forced air Capacity: 92,000 BTU's 5. Area Served: Upstairs Approximate Age: 10 years 6. Fuel Type: Natural gas 7. Unable to Inspect: 20% 8. Acceptable Heat Exchanger: 5 Burner 9. Acceptable Thermostats: Manual 10. Acceptable Blower Fan/Filter: Direct drive, Disposable filter 11. Acceptable Distribution: Insulated flex duct 12. Acceptable Flue Pipe: Double wall 13. Acceptable Combustion air Vented 14. Automatic safety controls present Yes 15. SA: 143.9 degrees RA: 81.2 degrees 16. Acceptable Heat rise: 62.7 degrees Attic Heating System 17. Acceptable Heating System Operation: Adequate 18. Manufacturer: Goodman 19. Model Number: GMTH115-5 Serial Number: 0207607758 20. Type: Forced air Capacity: 92,000 BTU's 21. Area Served: Downstairs Approximate Age: 10 years 22. Fuel Type: Natural gas 23. Unable to Inspect: 20% 24. Acceptable Heat Exchanger: 5 Burner 25. Acceptable Thermostats: Manual 26. Acceptable Blower Fan/Filter: Direct drive, Disposable filter 27. Acceptable Distribution: Insulated flex duct 28. Acceptable Flue Pipe: Double wall 29. Acceptable Combustion air Vented 30. Automatic safety controls present Yes 31. SA: 157.6 degrees RA: 80.0 degrees 32. Acceptable Heat rise: 77.6 degrees

Page 24 of 33 Pool/ Spa The following items are beyond the scope of the inspection & excluded from the report; operation of electric resistance heaters or solar heating systems, low voltage or electronic controls, chlorinating systems or ozone generators, pool water chemistry, flow rates, high or low pressure conditions or the adequacy of filters or heaters. Other items may be excluded, refer to the attached Standards of Practice for Pool & Spa Inspections. Behind home Swimming Pool 1. Acceptable Type: In ground 2. Current Status: Working 3. Acceptable Liner: Pebble Tec 4. Acceptable Deck: Kool Deck 5. Acceptable Coping: Kool Deck, Flagstone 6. Acceptable Drainage: In back yard 7. Acceptable Skimmer: Plastic 8. Acceptable Pool cleaning system: Pop-up heads 9. Acceptable Chlorinating System Chlorine floater 10. Acceptable Pump Motor: 240 volt 11. Acceptable Plumbing: PVC piping 12. Acceptable Leaks No 13. Acceptable Self fill mechanism: In the deck 14. Acceptable Filter: Sand 15. Acceptable Gauges and Controls: Present 16. Acceptable Shut-off Valve: Jandy valve 17. Acceptable Aerator: Edge mounted 18. Acceptable Back Wash Valve: Drains to hose 19. Acceptable Electrical: 120-240 Volts 20. Acceptable Timer: Mechanical 21. Acceptable Bonding: At pool moter 22. Acceptable Pool/ Spa Light: Working in conjunction with GfCI Protection 23. Acceptable GFCI Protection: Present/Working 24. Not Present Heater: None 25. Acceptable Ladder/Steps: Design in pool foundation 26. Not Present Pool slide None 27. Not Present Diving board: None 28. Acceptable Child safe barriers, gates & doors: Regulation handle mounted on slidding glass door Maintenance Advice UPON TAKING OWNERSHIP After taking possession of your new home, there are some maintenance and safety issues that should be addressed immediately. The following checklist should help you undertake these improvements: X Re-key or change the locks on all exterior entrances, for improved security. X Check that all windows and doors are secure. Improve window hardware as necessary. Security rods can be added to sliding windows and doors. Consideration could also be given to a security system. X Create a plan of action in the event of a fire in your home. Ensure that there is an operable window or door in every room of the house. Consult with your local fire department regarding fire safety issues and what to do in the event of fire. X Examine driveways and walkways for trip hazards. Undertake repairs where necessary. X Examine the garage and interior of the home for trip hazards. X Ensure that the grade of the land around the house encourages water to flow away from the foundation. X Hire a licensed Pest Control Service. Ask your neighbors for referrals. X If you have disturbed the ground within 16 inches of the foundation installing landscaping, plumbing, irrigation, lighting, gas lines or additional concrete work, call your Termite Pretreatment contractor for re treatment. Landscaping should not be installed within 16 inches of the foundation. Irrigation should be installed outside the plant line. X Investigate the location of the main shut-offs for the plumbing, heating and electrical systems. X Review your home inspection report for any items that require immediate repair or further investigation. Address these

Page 25 of 33 Maintenance Advice (Continued) areas as required. Follow up all items with your builder (if under warranty) until completed satisfactorily. REGULAR MAINTENANCE EVERY MONTH X Check that fire extinguishers are fully charged. Re-charge if necessary. X Examine heating/cooling air filters and replace or clean as necessary. See January 2000 Consumer Reports Ratings. X Inspect and clean electronic air cleaners. X Open and close all windows and doors to assure they operate freely. X Carefully inspect the condition of shower enclosures. Repair or replace deteriorated grout and caulk. Ensure that water is not escaping the enclosure during showering. Check below all plumbing fixtures for evidence of leakage. X Secure loose toilets, or repair flush mechanisms that run on. X Test all ground fault circuit interrupter (GFCI) devices. X Test all arc fault circuit interrupter (AFCI) devices. They are located in the main electrical panel. X Test the overhead garage door opener, to ensure that the auto-reverse mechanism is responding properly. Clean and lubricate hinges, rollers and tracks on overhead doors. Use Teflon spray on the hinges and rollers and the manufacturers recommended lubricant on the drive. SPRING AND FALL X Schedule routine preventative maintenance in March for air conditioners and October for furnaces and fireplaces. X Drain your water heater of built up sediment. X Clean gutters and downspouts. Ensure that downspouts are secure, and that the discharge of the downspouts is away from the foundation. X Trim back tree branches and shrubs to ensure that they are not in contact with the house. X Remove tree debris from your roof. Hire a licensed roofing contractor to do this. X Inspect the exterior walls and foundation for evidence of damage, cracking or movement. Watch for bird nests or insect activity. X Inspect all driveways, walkways, decks, porches, and landscape components for evidence of deterioration, movement or safety hazards. X Inspect for evidence of wood boring insect activity. Eliminate any wood/soil contact around the perimeter of the home. X Replace or clean exhaust hood filters. ANNUALLY X Replace smoke detector batteries. Use Lithium 9-volt batteries. X Have chimneys inspected and cleaned. X Arizona is an area prone to wood destroying insects (termites), have the home inspected by a licensed specialist. Preventative treatments may be recommended in some cases. UPON TAKING OWNERSHIP After taking possession of your new home, there are some maintenance and safety issues that should be addressed immediately. The following checklist should help you undertake these improvements: X Re-key or change the locks on all exterior entrances, for improved security. X Check that all windows and doors are secure. Improve window hardware as necessary. Security rods can be added to sliding windows and doors. Consideration could also be given to a security system. X Create a plan of action in the event of a fire in your home. Ensure that there is an operable window or door in every room of the house. Consult with your local fire department regarding fire safety issues and what to do in the event of fire. X Examine driveways and walkways for trip hazards. Undertake repairs where necessary. X Examine the garage and interior of the home for trip hazards. X Ensure that the grade of the land around the house encourages water to flow away from the foundation. X Hire a licensed Pest Control Service. Ask your neighbors for referrals. X If you have disturbed the ground within 16 inches of the foundation installing landscaping, plumbing, irrigation, lighting, gas lines or additional concrete work, call your Termite Pretreatment contractor for re treatment. Landscaping should not be installed within 16 inches of the foundation. Irrigation should be installed outside the plant line. X Investigate the location of the main shut-offs for the plumbing, heating and electrical systems. X Review your home inspection report for any items that require immediate repair or further investigation. Address these areas as required. Follow up all items with your builder (if under warranty) until completed satisfactorily. REGULAR MAINTENANCE EVERY MONTH X Check that fire extinguishers are fully charged. Re-charge if necessary. X Examine heating/cooling air filters and replace or clean as necessary. See January 2000 Consumer Reports Ratings. X Inspect and clean electronic air cleaners. X Open and close all windows and doors to assure they operate freely. X Carefully inspect the condition of shower enclosures. Repair or replace deteriorated grout and caulk. Ensure that water is not escaping the enclosure during showering. Check below all plumbing fixtures for evidence of leakage. X Secure loose toilets, or repair flush mechanisms that run on. X Test all ground fault circuit interrupter (GFCI) devices. X Test all arc fault circuit interrupter (AFCI) devices. They are located in the main electrical panel.

Page 26 of 33 Maintenance Advice (Continued) X Test the overhead garage door opener, to ensure that the auto-reverse mechanism is responding properly. Clean and lubricate hinges, rollers and tracks on overhead doors. Use Teflon spray on the hinges and rollers and the manufacturers recommended lubricant on the drive. SPRING AND FALL X Schedule routine preventative maintenance in March for air conditioners and October for furnaces and fireplaces. X Drain your water heater of built up sediment. X Clean gutters and downspouts. Ensure that downspouts are secure, and that the discharge of the downspouts is away from the foundation. X Trim back tree branches and shrubs to ensure that they are not in contact with the house. X Remove tree debris from your roof. Hire a licensed roofing contractor to do this. X Inspect the exterior walls and foundation for evidence of damage, cracking or movement. Watch for bird nests or insect activity. X Inspect all driveways, walkways, decks, porches, and landscape components for evidence of deterioration, movement or safety hazards. X Inspect for evidence of wood boring insect activity. Eliminate any wood/soil contact around the perimeter of the home. X Replace or clean exhaust hood filters. ANNUALLY X Replace smoke detector batteries. Use Lithium 9-volt batteries. X Have chimneys inspected and cleaned. X Arizona is an area prone to wood destroying insects (termites), have the home inspected by a licensed specialist. Preventative treatments may be recommended in some cases. Standards of Practice Table of Contents 1. Definitions and Scope. 2. Standards of Practice 2.1. Roof 2.2. Exterior 2.3. Basement, Foundation, Crawlspace & Structure 2.4. Heating 2.5. Cooling 2.6. Plumbing 2.7. Electrical 2.8. Fireplace 2.9. Attic & Insulation 2.10. Doors, Windows & Interior 3. Limitations, Exceptions & Exclusions 4. Glossary of Terms 1. Definitions and Scope 1.1. A Home Inspection is a non-invasive, visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling. Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems or portions of the home, as identified and agreed to by the Client and Inspector, prior to the inspection process. I. A home inspection is intended to assist in evaluation of the overall condition of the dwelling. The inspection is based on observation of the visible and apparent condition of the structure and its components on the date of the inspection, and not the prediction of future conditions. II. A home inspection will not reveal every concern that exists or ever could exist, but only those material defects observed on the day of the inspection. III. A home inspection can include a survey and/or analysis of energy flows and usage in a residential property if the client requests it. 1.2. A Material Defect is a condition of a residential real property, or any portion of it, that would have a significant, adverse impact on the value of the real property, or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect. 1.3. An Inspection Report shall describe and identify, in written format, the inspected systems, structures, and components of the dwelling, and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals, but this is not required.

Page 27 of 33 Standards of Practice (Continued) 2. Standards of Practice 2.1. Roof I. The inspector shall inspect from ground level or eaves: A. the roof covering; B. the gutters; C. the downspouts; D. the vents, flashings, skylights, chimney and other roof penetrations; and E. the general structure of the roof from the readily accessible panels, doors or stairs. II. The inspector is not required to: A. walk on any pitched roof surface. B. predict the service life expectancy. C. inspect underground downspout diverter drainage pipes. D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces. E. move insulation. F. inspect antennae, lightning arresters, de-icing equipment, or similar attachments. G. walk on any roof areas that appear, in the opinion of the inspector, to be unsafe. H. walk on any roof areas if it might, in the opinion of the inspector, cause damage. I. perform a water test. J. warrant or certify the roof. K. confirm proper fastening. 2.2. Exterior I. The inspector shall inspect: A. the siding, flashing and trim; B. all exterior doors, decks, stoops, steps, stairs, porches, railings, eaves, soffits and fascias; C. and report as in need of repair any spacings between intermediate balusters, spindles, or rails for steps, stairways, balconies, and railings that permit the passage of an object greater than 4 inches in diameter; D. a representative number of windows; E. the vegetation, surface drainage, and retaining walls when these are likely to adversely affect the structure; F. and describe the exterior wall covering. II. The inspector is not required to: A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent lighting. B. inspect items, including window and door flashings, which are not visible or readily accessible from the ground. C. inspect geological, geotechnical, hydrological and/or soil conditions. D. inspect recreational facilities or playground equipment. E. inspect seawalls, break-walls and docks. F. inspect erosion control and earth stabilization measures. G. inspect for safety-type glass. H. inspect underground utilities. I. inspect underground items. J. inspect wells or springs. K. inspect solar, wind, or geothermal systems. L. inspect swimming pools or spas. M. inspect septic systems or cesspools. N. inspect sprinkler systems. O. inspect drain fields or drywells. P. determine the integrity of the thermal window seals or damaged glass. Q. inspect any damaged glass. 2.3. Basement, Foundation & Crawlspace I. The inspector shall inspect: A. the basement; B. the foundation; C. the crawlspace; D. the visible structural components; E. and report on the location of under-floor access openings; F. and report any present conditions or clear indications of active water penetration observed by the inspector; G. for wood in contact or near soil; H. and report any general indications of foundation movement that are observed by the inspector, such as, but not limited to: sheetrock cracks, brick cracks, out-of-square door frames, or floor slopes; I. and report on any cutting, notching and boring of framing members which may present a structural or safety concern. II. The inspector is not required to:

Page 28 of 33 Standards of Practice (Continued) A. enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a hazard to the inspector. B. move stored items or debris. C. operate sump pumps with inaccessible floats. D. identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist spans or support systems. E. provide any engineering or architectural service. F. report on the adequacy of any structural system or component. 2.4. Heating I. The inspector shall inspect: A. the heating systems using normal operating controls, an describe the energy source and heating method; B. and report as in need of repair heating systems which do not operate; C. and report if the heating systems are deemed inaccessible. II. The inspector is not required to: A. inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, combustion air systems, fresh air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems or solar heating systems. B. inspect fuel tanks or underground or concealed fuel supply systems. C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the heating system. D. light or ignite pilot flames. E. activate heating, heat pump systems or other heating systems when ambient temperatures or other circumstances are not conducive to safe operation or may damage the equipment. F. override electronic thermostats. G. evaluate fuel quality. H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks. 2.5. Cooling I. The inspector shall inspect: A. the central cooling equipment using normal operating controls. II. The inspector is not required to: A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply adequacy of the cooling system. B. inspect window units, through-wall units, or electronic air filters. C. operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit, or when other circumstances are not conducive to safe operation, or may damage the equipment. D. inspect or determine thermostat calibration, cooling anticipation, or automatic setbacks or clocks. E. examine electrical current, coolant fluids or gases, or coolant leakage. 2.6. Plumbing I. The inspector shall: A. inspect and determine if the water supply is public or private; B. verify the presence of and identify the location of the main water shut-off valve; C. inspect the water heating equipment, including venting, connections, energy source supply system, and seismic bracing, and verify the presence or absence of temperature-pressure relief valves and/or Watts 210 valves; D. flush toilets; E. water-test sinks, tubs and showers for functional drainage; F. inspect the interior water supply, including all fixtures and faucets; G. inspect the drain, waste and vent systems, including all fixtures; H. describe any visible fuel storage systems; I. inspect the drainage sump pumps and test pumps with accessible floats; J. inspect and describe the water supply, drain, waste and main fuel shut-off valves, as well as the location of the water main and main fuel shut-off valves; K. inspect and report as in need of repair deficiencies in the water supply by viewing the functional flow in two fixtures operated simultaneously; L. inspect and report as in need of repair deficiencies in installation and identification of hot and cold faucets; M. inspect and report as in need of repair mechanical drain-stops that are missing or do not operate if installed in sinks, lavatories and tubs; and N. inspect and report as in need of repair commodes that have cracks in the ceramic material, are improperly mounted on the floor, leak, or have tank components which do not operate. II. The inspector is not required to: A. light or ignite pilot flames. B. determine the size, temperature, age, life expectancy or adequacy of the water heater. C. inspect interiors of flues or chimneys, combustion air systems, water softening or filtering systems, well pumps or tanks, safety or shut-off valves, floor drains, lawn sprinkler systems or fire sprinkler systems. D. determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply. E. determine the water quality or potability or the reliability of the water supply or source. F. open sealed plumbing access panels. G. inspect clothes washing machines or their connections.