Similar documents
County of Yolo Development Services Building Inspection Division

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

Carter's Oshkosh (SIS) # The Center at Pearland Parkway - Pearland, TX Scope Of Work / Bid Qualifications

SECTION DUCT INSULATION

Measure 1 Seal Ducts Components Inspected

Work Order (Bid Form) Upper East Tennessee Human Development Agency

City of Westerville Guide to Commercial Inspections

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

Architect s Project Number of 5 Decentralized HVAC Equipment District Master Specs 2013 Edition

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

Table of Contents... 1, 2. (EF) Equipment Floor... VISR EF 102 Water Heater VISR EF 104 Chiller VISR EF 105 End Suction Pump...

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

A. Section includes busway and fittings including plug-in units.

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Building Permit Application

Design & Construction Standards, Revised January

SECTION EXHAUST FANS PART 1 GENERAL

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents MEDIUM VOLTAGE VAULT DESIGN... 2 DIVISION LIST OF FIGURES...

Price Fan Powered Terminal Units

Permit Application Commercial / Industrial / Mutli-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE (Form #2)

DIVISION MEDIUM VOLTAGE VAULT DESIGN Contents

D. Provide UL-approved assemblies for pipes and ducts passing through fire-rated floors, walls, or partitions as required.

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

SECTION FUEL-FIRED UNIT HEATERS

SECTION AIR OUTLETS AND INLETS

A. ASTM E84 Standard Test Method for Surface Burning Characteristics of Building Materials

SECTION CONVECTORS

Indoor Air Quality and Mechanical Ventilation (Page 1 of 5)

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

GENERAL MECHANICAL SYSTEM REQUIREMENTS

IMC 2012 WORKBOOK Equipment and Appliances on Roofs or Elevated Structures

Our Shop is Your Shop

CONSTRUCTION DOCUMENTS NECESSARY FOR PLAN REVIEW

Bid Package 15A Mechanical

CONTACT LIST DOORS IN THE PATH OF EGRESS TRAVEL SHALL MEET THE REQUIREMENTS OF ICC / ANSI A117.1 : SECTION MANEUVERING CLEARANCES AT DOORS

Work Order (Bid Form) Blount County Community Action Agency, Inc.

City of Omaha Plans and Permits Commercial Alterations and Conversions Building Permit Submittal Checklist

SECTION AIR DISTRIBUTION

Compliance Certificate

Boulder City NV Prepared by (Print Name) Signature Date

CERTIFICATE OF FIELD VERIFICATION & DIAGNOSTIC TESTING (Page 1 of 8)

New Construction Procurement Guidelines for the Pacific Northwest

2012 Fiscal Impact International Mechanical Code

COMMERCIAL TENANT IMPROVEMENT PERMIT APPLICATION

Hardin County Planning and Development Commission

Permit Application Commercial / Industrial / Multi-Family BUILDING, ELECTRICAL, MECHANICAL, PLUMBING, BUILDING SEWER & WATER SERVICE

Mechanically Fasten Duct Sections. Code Reference: 2013 Title 24, Part 6 Standards 120.4(a) Sealed Openings. Drawbands

FIELD COPY ATTACHMENT

Village of Gurnee Construction Documents Submittal Requirements

Standards for Jackson EMC s Right Choice Program Revised: June 2011

WeatherSmart Air Barrier Installation Guide

2005 BUILDING ENERGY EFFICIENCY STANDARDS

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials

DESIGN CHECKLIST PROJECT NAME DISCIPLINE DATE TYPE REVIEW REVIEWER DRAWINGS REVIEWED

CONSTRUCTION REQUIREMENTS

UNDP / PAPP OFFICE BUILDING RAMALLAH HVAC WORKS

SECTION AIR-TO-AIR ENERGY RECOVERY EQUIPMENT

ENERGY STAR Qualified Homes National Program Requirements, Version 3.0

GENERAL MECHANICAL SYSTEM REQUIREMENTS

SECTION PACKAGED, OUTDOOR, CENTRAL-STATION AIR-HANDLING UNITS

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

REScheck Software Version Compliance Certificate

B. Provide equipment complying with this specification and manufactured by one of the following:

Project Number BID NO. CAG 18 2 ROOF REPLACEMENT FOR HARFORD COUNTY PUBLIC SCHOOLS NORTH HARFORD ELEMENTARY. Addendum # 2

B. Refer to Section : Air Distribution for lined ductwork requirements.

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5

4. Number of drawings required: ( ) Locations of nearest streets

SECTION HVAC GRAVITY VENTILATORS

INSTALLING WATER-RESISTIVE BARRIERS & FLASHING

ELECTRON BEAM DUMP - ROOM DATA SHEET

INSPECTION GUIDELINES: JOIST AND UNDERFLOOR COMBO

SECTION ENCLOSED BUS ASSEMBLIES

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

SECTION DUCTS PART 1 GENERAL 1.01 SUMMARY

MEP Seismic & Wind Provisions of ASCE Prepared for the 2017 Rochester Engineering Symposium Richard Sherren, P.E.

SECTION HVAC DUCTS AND CASINGS

YORK UNITIZED ENERGY RECOVERY VENTILATOR (ERV) Superior air-flow 300 6,200 CFM

Compliance Certificate

SECTION 15A AIR CONDITIONING

2005 Seismic Bracing System. Superstrut Metal Framing

A.ENVELOPE AIR SEALING

KEARNEY REGIONAL AIRPORT NEW HANGAR KEARNEY, NEBRASKA 1238

MicroMetl ISOLATION CURB CATALOG. for York ZH,DH,DM,BP ; DF ; DJ 150; DR ;ZF,ZJ 150

B. Shop Drawings: For air terminal units. Include plans, elevations, sections, details, and attachments to other work.

Code Enforcement Division. Notice to Industry

2005 Seismic Bracing System. Kindorf Modular Metal Framing

WEST VIRGINIA UNIVERSITY ALUMNI CENTER Morgantown, West Virginia

GENERAL PLAN REVIEW REQUIREMENTS

KITCHEN REMODELS CITY OF MISSION VIEJO BUILDING SERVICES DIVISON 200 CIVIC CENTER, MISSION VIEJO, CA (949)

A LOOK INTO THE 2015 IECC RESIDENTIAL PROVISIONS. Presented by: Shaunna Mozingo, Colorado Code Consulting

CITY OF CALABASAS RESIDENTIAL PLAN REQUIREMENTS 1 OF 5 8/2017 PLAN INFORMATION

IECC 2006 with Hawaii Amendments

Commissioning Agent s Guide for Inspecting & Testing Access Floor Air Plenums

ROUTT COUNTY REGIONAL BUILDING DEPARTMENT 136 * P.O.

ENERGY STAR Homes version 3 Designing and Building to Meet the 2011 Changes. Thursday, February 24, 2011

WELD COUNTY SOUTHWEST BUILDING HVAC EVALUATION 4209 COUNTY ROAD 24 ½, FIRESTONE, COLORADO August 4, 2017

SECTION FIELD PANELS

Price High Performance Horizontal Fan Coil Units

PermaShield Pipe. Fab-Tech, Inc. SECTION 1589X Specification for Coated Corrosive Fume Exhaust Duct

SECTION SECONDARY UNIT SUBSTATIONS

Transcription:

TYP. SINGLE PLY ROOFING ROOF SHEETING BROAN VENT CAP #10 x 1" GASKETED SMS TYP. 4 SIDES 8" FRAMED CURB HVAC SYSTEMS "BASIS OF DESIGN" ROOF INSULATION R-19 WALL INSULATION R-13 LIGHTING EFFIECNCY PER STANDARDS / BY LIGHTING DESIGNER / SEE "E" SHEETS LIGHTING CONTROLS DESIGN PER C.E.C. T24 REQUIREMENTS MECHANICAL SYSTEMS GAS / ELECTRIC PACKAGE EQUIPMENT HVAC SYSTEM LEVEL OF QUALITY BASIC TO MEET MINIMUM STANDARDS CONTROLS T24 PROGRAMMABLE THERMOSTATS VENTILATION REQUIREMENTS PER T24 REQUIREMENTS HVAC SYSTEM AMBIENT DESIGN INDOOR OCCUPIED CONDITIONS INDOOR UNOCCUPIED CONDITIONS WATER HEATER TANKLESS HIGH EFFICIENCY FENESTRATION N/A LOAD CALCULATION METHOD(S) ASHRAE STANDARDS / C.E.C. ZONE 14 HVAC SYSTEM SELECTION TYPE BY OWNER ARCHITECT MECHANICAL DESIGNER END X USER SYMBOL ABBREV. HVAC LEGEND DUCT WITH EXTERNAL WRAP DUCT WITH INTERNAL LINER TYPICAL DUCT NO LINER OR WRAP FLEXIBLE DUCT EXTENSION TO RIGID DUCT WHEN SHOWN R/A DUCT, FLEX UNLESS NOTED OTHERWISE S/A DUCT, FLEX, UNLESS NOTED OTHERWISE E/A DUCT, UNLESS NOTED OTHERWISE MANUAL VOLUME DAMPER FIRE DAMPER & SMOKE DAMPER DESCRIPTION DWG.NO. DRAWING LIST M-0 DRAWING INDEX, HVAC LEGEND, HVAC SCHEDULES, GENERAL NOTES, AND DETAILS M-1 HVAC FLOOR PLAN M-2 DEMO & NEW EQUIPMENT ROOF PLANS T24-1 TITLE 24 COMPLIANCE REPORTS T24-2 TITLE 24 COMPLIANCE REPORTS DESCRIPTION 1 TYPICAL ROOF EXHAUST VENT DETAIL NTS CEILING REGISTER (RETURN OR OUTSIDE AIR) CEILING DIFFUSER (SUPPLY) GENERAL NOTES CEILING REGISTER (EXHAUST) CEILING REGISTER W/RA BOOT (SHORT LINE INDICATED BOOT DIRECTION) SUPPLY AIR DUCT SECTION 1. COORDINATE THE WORK OF THIS SECTION WITH THE WORK OF OTHER TRADES AND ALL JOB CONDITIONS. 2. UNLESS NOTED OTHERWISE ALL SYSTEMS, EQUIPMENT, MATERIALS, FABRICATION AND INSTALLATIONS SHALL COMPLY WITH ALL LOCAL, COUNTY, AND STATE CODES. 2 EA. - # 12 WIRES AT OPPOSING CORNERS T-BAR GRID 2 T-BAR REGISTER HANGING DETAIL NTS RETURN OR EXHAUST AIR DUCT SECTION DUCT SMOKE DETECTOR UNIT I.D. / UNIT # XX DETAIL # SHEET # X T LT THERMOSTAT RS AS HVAC EQUIPMENT SCHEDULE REMOTE SENSOR REMOTE AVERAGING SENSOR OUTSIDE AIR SUPPLY AIR RETURN AIR MARK MANUFACTURER MODEL TOTAL CAP. HEAT CAP. INPUT DESIGN CONDITION CFM / " W.C. VOLT / PHASE M.C.A. MAX FUSE SEER / *EER WEIGHT NOTES AC-1 CARRIER 48VL480606TF 48,000 90,000 BTUH 95/80/67 1600 /.9 480 / 3 12.1 15 14.2 / 12 490 1 AC-2 CARRIER 48TCDD24H1M6_6V2G 242,000 220,000 BTUH 95/80/67 8000 / 1.2 480 / 3 43.6 60 ** / 9.8 2072 2, 3 XX X OSA S/A R/A 3. UNLESS NOTED OTHERWISE CONTRACTOR SHALL PROVIDE ALL EQUIPMENT, MATERIALS, LABOR, AND SERVICES AS REQUIRED FOR A COMPLETE INSTALLATION. ANY AND ALL ITEMS NOT SPECIFICALLY NOTED SHALL BE INCLUDED TO MAKE COMPLETE FUNCTIONING SYSTEMS. 4. PROVIDE SEISMIC RESTRAINTS TO ALL DUCT, PIPE AND EQUIPMENT SUPPORTS IN ACCORDANCE WITH "SMACNA" GUIDELINES FOR SEISMIC RESTRAINTS OF MECHANICAL SYSTEMS (2008). 5. EQUIPMENT ANCHORAGE: ALL MECHANICAL EQUIPMENT SHALL BE BRACED OR ANCHORED TO RESIST A HORIZONTAL FORCE ACTING IN ANY DIRECTION USING THE FOLLOWING CRITERIA: FIXED EQUIPMENT ON GRADE 33% OF OPERATING WEIGHT FIXED EQUIPMENT ON STRUCTURE 50% OF OPERATING WEIGHT FOR FLEXIBLY MOUNTED EQUIPMENT, USE 2 TIMES THE ABOVE VALUES. FOR SIMULTANEOUS VERTICAL FORCE, USE 1/3 TIMES THE HORIZONTAL FORCE. WHERE ANCHORAGE DETAILS ARE NOT INDICATED ON THE DRAWINGS, THE FIELD INSTALLATION SHALL BE SUBJECT TO THE APPROVAL OF THE ARCHITECT WHERE ANCHORAGE IS INDICATED ON THE CONTRACT DOCUMENTS, ANCHORAGE SHALL BE AS PER THE CONTRACT DOCUMENTS. 6. PENETRATIONS OF PIPES, CONDUITS, ETC., IN WALLS REQUIRING PROTECTED OPENING SHALL BE FIRE STOPPED. FIRE STOP MATERIAL SHALL BE A TESTED ASSEMBLY APPROVED BY THE STATE FIRE MARSHAL. 7. SEAL ALL DUCT AIR TIGHT WITH WATER BASED UL-181 SEALER. 8. FABRICATE AND INSTALL ALL DUCT WORK PER "SMACNA" DUCT CONSTRUCTION STANDARDS. ALL DUCT WORK UP STREAM OF DAMPERS SHALL BE DESIGNED AT 2" W.G. 9. PROVIDE COMPLETE SYSTEMS AIR BALANCE, SYSTEMS TESTING, AND ENERGY COMPLIANCE REPORTS FOR ALL HVAC SYSTEMS. AIR BALANCE CONTRACTOR TESTING SHALL COMPLY WITH "SMACNA" OR "AABC" STANDARDS. EF-1 BROAN L300 300 /.25 115 / 1 185 WATT 4, 5 EF-2 BROAN L300 300 /.25 115 / 1 185 WATT 4, 5, 6, T VENSTAR T8850 COLOR, TOUCH SCREEN, DIGITAL, PROGRAMMABLE THERMOSTAT AS VENSTAR ACCTSEN 10K REMOTE SENSOR FOR USE AS A SQUARE ROOT AVERAGING CONTROL SYSTEM 7 LT HONEYWELL T4150 LINE VOLTAGE THERMOSTAT FOR USE WITH EXHAUST FANS 10. ALL FABRICATED DUCT WORK SHOWN ON DRAWINGS SHALL BE LINED WITH 2" LINER. LINER SHALL BE SECURED WITH UL-181 APPROVED ADHESIVE AND SPOT WELD PINS. NO ADHESIVE STICKS OR PINCH NAILS WILL BE ALLOWED. 11. ALL EXTERNAL DUCT WRAP SHALL BE FOIL FACED R-4.2, SECURE WITH WIRE AND SEAL ALL SEAMS WITH TAPE. 12. HVAC SYSTEMS CIRCULATING FANS SHALL RUN ON AN CONTINUOUS BASIS DURING ALL OCCUPIED PERIODS. 13. CONTRACTOR SHALL MAINTAIN AND PROVIDE AS BUILT DRAWINGS. DELIVER TO OWNER UPON COMPLETION OF ALL WORK RELATED TO THIS TRADE. 3 NTS HVAC EQUIPMENT NOTES NOTE # NOTE DESCRIPTION 1 REPLACE EXISTING CURB WITH NEW FACTORY CURB / PROVIDE WITH FACTORY AUTOMATIC OUTSIDE AIR HOOD 2 PROVIDE WITH SPRING ISOLATION EARTHQUAKE APPROVED CURB. NEW CURB SHALL REPLACE EXISTING ROOF CURB 3 PROVIDE WITH THE FOLLOWING; 2 STG COOLING / RA + SA SMOKE DETECTORS / CO2 CONTROL / DIFF-TEMP ECONOMIZER / POWER EXHAUST / POWERED CONVENIENCE OUTLET 4 SWITCH INDEPENDENT FROM LIGHTS 5 PROVIDE WITH MODEL # 611CM ROOF VENT CAP (CURB BY FRAMING CONTRACTOR) 6 PROVIDE WITH LINE VOLT THEMOSTAT 7 WIRE SENSORS USING 22/3 SHIELDED CABLE AIR DISTRIBUTION SCHEDULE 14. UNLESS NOTED OTHERWISE ALL FABRICATED DUCT WORK DIMENSIONS AS SHOWN ON DRAWINGS ARE OUTSIDE DIMENSIONS OF SAME, WHETHER THE DUCT WORK IS LINED OR WRAPPED. 15. INITIALLY PROGRAM CONTROLS FOR OWNER AS REQUIRED. 16. ALL FLEXIBLE DUCT, RIGID DUCT WITH WRAP, AND LINER SHALL BE R-4.2 INSULATED TO MEET ENERGY CODE REQUIREMENTS. WORK BY OTHER TRADES: 1. PLUMBER TO PROVIDE: GAS PIPING, CONDENSATE DRAINS, AND FINAL CONNECTIONS FOR SAME. 2. ELECTRICIAN TO PROVIDE: LINE VOLTAGE SUPPLY & DISCONNECTS FOR HVAC EQUIPMENT, FANS, AND FINAL CONNECTION OF SAME. 4 NTS MANUFACTURER DESCRIPTION MODEL NOTES METAL AIRE HARD CEILING CEILING S/A REGISTER 9000-2 WITH OBD (SIZE PER DRAWING) METAL AIRE HARD CEILING R/A REGISTER RH NO OBD (SIZE PER DRAWING) METAL AIRE HARD CEILING RETURN FILTER GRILL RHFG NO OBD (SIZE PER DRAWING) METAL AIRE HARD CEILING EXHAUST REGISTER RH NO OBD (SIZE PER DRAWING) METAL AIRE SIDE WALL S/A REGISTER H4004 WITH OBD (SIZE PER DRAWING) METAL AIRE SIDE WALL R/A REGISTER RH NO OBD (SIZE PER DRAWING) 3. FRAMING CONTRACTOR: PROVIDE CUT OUTS, WALL AND ROOF HEAD OUTS OF OPENINGS, AND PLATFORMS OR STANDS WHERE NOTED. APPLICABLE CODES AND STANDARDS 2013 CALIFORNIA BUILDING CODE (CBC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 2 2013 CALIFORNIA ELECTRICAL CODE (CEC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 3 2013 CALIFORNIA MECHANICAL CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 4 2013 CALIFORNIA PLUMBING CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 5 2013 CALIFORNIA ENERGY CODE CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 6 DESERT AIR DESIGN GROUP 6763 SVL BOX, VICTORVILLE CA. 92395 PHONE: 760 244-6796 CELL: 760 559-0395 2013 CALIFORNIA FIRE CODE (CFC) CALIFORNIA CODE OF REGULATIONS (CCR) TITLE 24, PART 9 "SMACNA" HVAC DUCT CONSTRUCTION STANDARDS / METAL AND FLEXIBLE THIRD EDITION 2005 "SMACNA" SEISMIC RESTRAINT MANUAL FOR MECHANICAL SYSTEMS THIRD EDITION - MARCH, 2008 5 NTS "ASHRAE" DESIGN GUIDELINES

KEY NOTES 1 R/A DUCT MOUNT, CO2 SENSOR. LOCATE IN AN EASILY ACCESSIBLE LOCATION. 2 R/A and S/A PLENUMS SHALL BE LINED WITH 2" LINER. USE LINER ADHESIVE AND WELD PINS TO ATTACH LINER. 3 ALL SPIRO-PIPE AND FITTINGS SHALL BE WRAPPED WITH A MINIMUM OF R-4.2 FOIL FACE WRAP. GENERAL NOTES 1. FOR GENERAL NOTES RELATED TO ITEMS ON THIS SHEET (M-1) SEE GENERAL NOTES ON M-0 22"x22" 350 CFM 22"x22" 350 CFM 22"x22" 350 CFM 5 EA. EXHAUST FANS EF-1 EF-1 EF-2 EF-1 EF-2 12"x12" 320 CFM TYP. 8 EA. 22"x46" 950 CFM AS 175 CFM 175 CFM T 175 CFM 175 CFM AS 220 CFM 220 CFM 135 CFM 135 CFM LT LT 8"x8" 80 CFM EF-1 3 AS 22"x46" 950 CFM 3 12"x12" 250 CFM TYP. 12 EA. AS 250 CFM 22"x46" 950 CFM 22"x46" 950 CFM AS T 185 CFM 185 CFM AS 190 CFM 190 CFM 21"x44" UP TO 25-1/4"x63-1/4" 44"x24" 2 CO 1 21"x48" UP TO 21-1/2"x68-3/4" 205 CFM 205 CFM 200 CFM DESERT AIR DESIGN GROUP 6763 SVL BOX, VICTORVILLE CA. 92395 PHONE: 760 244-6796 CELL: 760 559-0395 HVAC FLOOR PLAN SCALE: 1/8 " = 1'-0" N

KEY NOTES 1 PATCH EXISTING SINGLE PLY ROOF AS REQUIRED TO ACCEPT NEW EQUIPMENT 2 DEMO EXISTING TRANE AC UNIT'S. 1 EA. - MOD# BYC030, WEIGHING 690 lbs. AND 1 EA. - MOD# SAHB200, WEIGHING 2320 lbs. CONFIRM AND JUSTIFY WEIGHTS SHOWN ARE CORRECT. DEMO ALL DUCT WORK CONNECTED TO THESE EXISTING UNITS AS WELL AS ALL EXISTING DUCT WORK LOCATED IN ATTIC. EXISTING EX. FAN TO REMAIN KEY NOTES 3 COORDINATE NEW ELECTRICAL, GAS, AND DRAIN LOCATIONS WITH PLUMBING AND ELECTRICAL CONTRACTORS AS REQUIRED. 4 ROOFING PATCH, NEW FLASHING'S, AND ALTERATIONS OF ROOF SURFACE AS REQUIRED BY OTHERS. 5 NEW FRAMED ROOF EX. FAN CURBS AND ROOF PATCH BY OTHERS. PROVIDE NEW VENT CAP FOR EXHAUST FANS AS NOTED ON EQUIPMENT SCHEDULE. 6 EXISTING EQUIPMENT ENCLOSURE TO REMAIN. ROOF STRUCTURE COORDINATION NOTES REMOVE AND REPLACE WITH NEW 2 EA. - ROOF TOP HVAC UNITS. PROVIDE STRUCTURAL CALCS TO JUSTIFY NEW HVAC UNIT CURB CORNER LOADS ON (E) ROOF FRAMING. CONTRACTOR SHALL PROVIDE NEW CURBS WITH CERTIFIED DRAWINGS AND PRODUCT DATA AS WELL AS AS-BUILT ROOF FRAMING PLAN TO ARCHITECT FOR STRUCTURAL REVIEW AND SUPPORTING CALCULATIONS. SEE DRAWING A-1, DEFERRED APPROVAL NOTE. NO EQUIPMENT SHALL BE ORDERED UNTIL STRUCTURAL JUSTIFICATION IS APPROVED BY ARCHITECT. EXISTING EX. FAN 1 2 EXISTING ROOF HATCH TO REMAIN 3 4 AC-1 5 NEW EXHAUST FAN VENT TYP. 5 EA. 5 EXISTING ROOF HATCH AC-2 1 2 6 3 4 6 DESERT AIR DESIGN GROUP 6763 SVL BOX, VICTORVILLE CA. 92395 PHONE: 760 244-6796 CELL: 760 559-0395 DEMO HVAC ROOF PLAN SCALE: 1/16 " = 1'-0" NEW HVAC EQUIPMENT ROOF PLAN SCALE: 1/16 " = 1'-0" N N