BLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM

Similar documents
HYDRAPEL SYSTEM. For Water Repellent Concrete Masonry

DETERMINING THE WATER REPELLANCY AND DEPTH OF PENETRATION OF PENETRATING CONCRETE TREATMENTS

Concrete Masonry Unit Samples 45 & 46

Feasibility of integral water repellent admixtures in low pressure compatible injected fill grouts

PERFORMANCE-RELATED SPECIAL PROVISION FOR HIGH PERFORMANCE CONCRETE MIX DESIGNS FOR CONCRETE SUPERSTRUCTURE (Tollway)

1-2-3MORTAR Modified Portland cement based mortar, to be used to adhere any prefabricated construction elements

Testing of Concrete Blocks

ENGINEERED BRICK MASONRY STANDARDS

By CTS Cement Manufacturing Corp.

SIDER-BASE CONCENTRATE AAC/ MONOSIDERAL AAC THE ULTIMATE OLD-WORLD AERATED CONCRETE-AAC DECORATIVE STUCCO SYSTEM

Conditions of the Contract and Division 1 General Requirements are a part of this section.

B. American Concrete Institute 1. ACI 302, 1R-89 Guide for Concrete Floor and Slab Construction

Inspection and Approval of Asphalt Field Laboratories

OHD L-54 STANDARD METHOD OF TEST FOR MAKING, CURING, AND TESTING CEMENT-TREATED BASE FIELD SAMPLES

Concrete Field Testing Technician Study Guide

1. Payment for concrete sidewalks is on square foot basis. a. Limits for measurement for trench excavation as follows:

SECTION INSTALLATION AND/OR REPLACEMENT OF MASONRY UNITS AND REPOINTING

Tex-239-F, Asphalt Release Agent

Laboratory Manual. Concrete and aggregate. Content

The Admixture Systems business of BASF Corporation previously conducted business as Degussa Admixtures, Inc. and Master Builders, Inc.

New SSPC Moisture Testing Guide and Pinhole Standard. Kenneth A. Trimber KTA-Tator, Inc.

Foundations. Issue. Slab-On-Grade Liquid Water Control (See Figure 2-2) Goals. Guidance

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 03 - CONCRETE

Paragraph Description Page No General Materials Concrete Masonry Work Altitude Valve Vault Cover 25-4

SECTION SPLIT FACE CONCRETE MASONRY UNITS

CATEGORY 500 PAVING HIGH FRICTION SURFACE TREATMENT

SECTION UNIT PAVERS

Copyright 2002 AIA MASTERSPEC 05/02

REFLECTIVE FACE CONCRETE MASONRY UNITS

September 1, 2003 CONCRETE MANUAL SPECIAL TYPES OF CONCRETE

STUDY ON WETTING AND DRYING OF CLAY BRICK HAVING SURFACE COATINGS

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

Tex-424-A, Obtaining and Testing Drilled Cores of Concrete

Tolerances- Section

Standard Test Methods for Wetting and Drying Compacted Soil-Cement Mixtures 1

QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS SECTION 1902 QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS

Tests of Bricks. 1 - Dimension Test. Purpose of test:- Standard specification:- Test specimen:- Notes:

ITEM P-631 REFINED COAL TAR EMULSION WITH ADDITIVES, SLURRY SEAL SURFACE TREATMENT

Concrete Masonry Units

FREEZING AND THAWING TESTS OF COMPACTED SOIL-CEMENT MIXTURE

NTPEP Evaluation of Rapid Set Concrete Patching Materials for Portland Cement Concrete

A. Section includes historic treatment work consisting of rep ointing brick masonry as follows:

State of Nevada Department of Transportation Materials Division METHOD OF TEST FOR DENSITY (UNIT WEIGHT) AND VOLUME OF CONCRETE

QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS SECTION 1902 QUALITY CONTROL PROGRAM FOR PRECAST CONCRETE PRODUCTS

SECTION SELF-ADHERING SHEET FLASHING

TESTING ELASTOMERIC CONCRETE

TEST PROCEDURE SUMMARY

CONCRETE POLISHING SPECIFICATION NEW OR EXISTING CONCRETE

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, EDITION OF 1990

May 1, 2000 LAB MANUAL SPECIFIC GRAVITY & ABSORPTION of COARSE AGGREGATE AASHTO Designation T 85 (Mn/DOT Modified)

Standard Test Method for Foaming Agents for Use in Producing Cellular Concrete Using Preformed Foam 1

METHOD OF TEST FOR EVALUATION OF SUPERPLASTICIZING ADMIXTURES FOR CONCRETE

SECTION GROUND FACE CONCRETE MASONRY UNITS

Section Fluid Applied Waterproofing

Brick Masonry. Best Practices Guide

DIVISION 9 - FINISHES Section Protective Coatings

CONCRETE TILE PAVERS

TESTING SINGLE-COMPONENT POLYURETHANE WATERPROOFING

Vertigo Cladding Board

CONSTRUCTION SPECIFICATION FOR CRACK REPAIR - CONCRETE

ITEM NO SLIPLINING GROUT

Concrete Masonry. Weights and Process. Grades & Types

STUDY GUIDE WACEL CONCRETE/MASONRY STRENGTH TESTING TECHNICIAN

WYOMING DEPARTMENT OF TRANSPORTATION. SUPPLEMENTARY SPECIFICATION FOR STRUCTURAL CONCRETE WITH QUALITY CONTROL and QUALITY ACCEPTANCE

SPECIAL SPECIFICATION 4491 Type CAC Concrete

B. Samples: Submit, for verification purposes, samples of the following:

SPECIAL PROVISION FOR FURNISHING AND PLACING MARSHALL HMA MIXTURE (WITH SAMPLING BEHIND THE PAVER)

Madewell Products Corporation December Industrial Court Alpharetta, GA Office: (770) Fax: (770)

SEALING PAVEMENT CRACKS WITH HIGH MOLECULAR WEIGHT METHACRYLATES

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS

SECTION 213 ENGINEERING FABRICS

SECTION 941 PRECAST REINFORCED CONCRETE BARRIERS

MASTERFLEX 900-FUKO Injection System

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1120 MIXTURE DESIGN FOR CHEMICALLY STABILIZED SOILS. June 13, 2011

Construction Standards PAGE

TESTING APPLICATION STANDARD (TAS) No TEST PROCEDURE FOR WIND AND WIND DRIVEN RAIN RESISTANCE OF DISCONTINUOUS ROOF SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS REPORT HOLDER: PAREX USA, INC.

CRD-C Standard Test Method for Comparing Concretes on the Basis of the Bond Developed with Reinforced Steel

Limerock Bearing Ratio Technician Training Course

MONOBASE AAC/ SIDER-PLAST THE ULTIMATE EXTERIOR HARD COAT STUCCO SYSTEM FOR AUTOCLAVED AERATED CONCRETE

SECTION BRICK MASONRY ASSEMBLIES

TESTING APPLICATION STANDARD (TAS) No STANDARD REQUIREMENTS FOR CONCRETE ROOF TILES

Effective Mortar Specifications. Jamie Farny PCA Market Manager Buildings June 24, 2015

TESTS ON BRICKS a. COMPRESSIVE STRENGTH OF BRICK

Dryshake CSI Format Section 07160

FIRE RESISTANCE OF EXPANDED SHALE, CLAY AND SLATE CONCRETE MASONRY

SECTION EMBEDDED CMU/SPLIT FACE ARCHITECTURAL PRECAST/SITECAST CONCRETE. A. Site Cast or Tilt-Up CMU/Split Face Concrete Panels.

APPENDIX D ANSWERS TO STUDY QUESTIONS/PROBLEMS

Guide Specification for the OSI QUAD Window and Door Flashing System

Application Instructions for Dryvit Backstop NT For Use Beneath Claddings Other Than Dryvit EIFS

CONSTRUCTION SPECIFICATION FOR BRICK GUTTER INDEX TS SCOPE...3 TS REFERENCES...3 TS DEFINITIONS...3

1. Division 09 Section "Rough Carpentry."

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 888 PORTLAND CEMENT CONCRETE PAVEMENT USING QC/QA.

EVERLAST CONCRETE TECHNOLOGIES PROTECTION PRODUCTS SECTION CONCRETE ADDITIVES AND ADMIXTURES

SAMPLE SPECIFICATIONS FOR PREFABRICATED FRP LIFT STATIONS

3.1 General. Type of soil Type and quantity of fibers Length of fibers Moulding pressure Type and quantity of stabilizer

CEMENTITIOUS CRYSTALLIZING WATERPROOFING PART 1 GENERAL

Frequently asked questions about Alcolin PU Sealant & Adhesive

SECTION SURFACE-APPLIED CRYSTALLINE WATERPROOFING AND CONCRETE REPAIR

Transcription:

BLOCKTITE SYSTEM WATER-REPELLENT ADMIXTURE CERTIFICATION PROGRAM Mix Performance Worksheet Testing Procedures/Protocol Test Results, Calculations Certificate of Compliance The Euclid Chemical Company 19218 Redwood Road Cleveland, Ohio 44110 1-800-321-7628 www.euclidchemical.com

Water Repellent Certification Program The Euclid Chemical Company has developed a water repellent certification program for block producers using EUCON BLOCKTITE and/or HYDRAPEL admixtures. After successful evaluation, a producer is authorized to manufacture water repellent-specified concrete masonry units using Euclid Chemical admixtures. Dosage rates are established by mix design and production plant using established ASTM and NCMA-developed test methods. The producer is advised by Euclid Chemical to periodically test water repellent production by spot-checking puddle retention and/or spray-bar performance. Your Euclid Chemical sales representative should be notified when significant changes in materials, mix design, or manufacturing equipment has occurred. Verification can be facilitated by the local salesman or by the masonry market segment manager for Euclid Chemical. Below is an outline of our evaluation procedures. Step 1: It is recommended that mix design data is obtained and reviewed for possible anomalies prior to conducting plant evaluations. Further mix design and/or machine adjustments may be required to achieve desired performance. If a chemically similar, competitive water repellent admixture (from a manufacturer other than Euclid Chemical) is currently being used without incident, substituting it with EUCON BLOCKTITE (at an equal dosage rate), is acceptable providing that comparable performance is observed. Step 2: At least two different dosages (per mix design) will be evaluated by a Euclid Chemical sales or technical specialist to determine optimal loading rate. Physical appearance, block weight, and machine response will be monitored. A set of 6 test block per mix will be marked with spray paint (for mix identification), and cured as normal before isolating for pick-up. All pertinent data will be collected and included in a final report. Step 3: Water repellency can be evaluated on-site (using standardized equipment and procedures) or sent to The Euclid Chemical Company technical center in Cleveland, Ohio. Euclid sales representatives can conduct field re-certification if mix design or process changes have occurred, or when the initial certification period has expired.

Method 1 Water Bead/Puddle Retention Test: This test measures a) the ability to demonstrate surface repellency, and b) the length of time that water beads remain on the surface before evaporating or being absorbed. This simple lab and field test is highly recommended for prequalifying experimental production runs, and for periodic checks on water repellent performance. Method: - Three full-sized masonry units are tested from each test mix submitted. Units shall have no dust or visible moisture on the surface. - Place unit in a container with about 8-10 lbs of dry sand at the bottom. Place the block with face shells directed upward in the container. Level using a torpedo level. - Place 4ml of potable water at 5 discrete locations per block. Observe closely for the first minute and record if water is absorbed during this initial stage. Make additional recordings at 15 minutes, 30 minutes, 1 hour, 2 hours, and 4 hours. Performance criteria established by NCMA are as follows: Time Scale Excellent Good Marginal Poor 4 Hours 15 drops 10-15 drops 5-10 drops 0-5 drops remaining remaining remaining remaining If a marginal rating results, The Euclid Chemical Company will recommend adjustments to the mix design, aggregate blend, and/or dosage rate of EUCON BLOCKTITE or HYDRAPEL before retesting.

Method 2 Water Uptake of Concrete Masonry Units: This is a test that has been modified from ASTM C 1403 Standard Test Method for Rate of Water Absorption of Mortar to accommodate the testing of concrete masonry units. Three full size CMU or three face shell specimens, saw-cut from three full sized units are required per test mix. The purpose of this test is to measure the capillary absorption of the production samples. Method: - Prepare the sample by saw cutting the face shell from CMU keeping the web tabs as short as possible without damaging the back of the face shell. - Measure dimensions (height, width, length) in accordance with ASTM C-140. - Dry the specimens in a ventilated oven at 60ºC for a minimum of 24 hours and until the weight change is not greater than 0.2% over a one-hour period. - Allow test specimens to cool (at room temperature) for a minimum of 2 hours or until ambient temperature is reached. - Begin the testing within 24 hours after reaching temperature equilibrium.

Prepare an immersion container that will minimize evaporation with an airtight seal. - Use specimen supports that do not cover more than ten percent of the surface area and which do not rust, expand or shrink as a result of exposure to water. - Water should be 75º (+/- 15 o ) and filled to 0.12 (+/-.02) inches above the specimen supports when the samples are added. - Record the weight of each specimen as Wo to the nearest 0.01 lb. - Immediately place the specimen into immersion tank with the smooth, machined face in contact with the specimen supports. - Cover the tank to minimize evaporation. Take readings at 15 minutes, then at 1, 2, 4, and 24 hours by removing specimen from immersion tank and blotting the surface with a damp cloth prior to weighing (using the ASTM C 140 method). Do not blot excessively; complete specimen weighing within 1minute. - Record each weight as Wt where T is the time in hours since starting the test. - After weighing, return the specimen to immersion tank. - Adjust water to maintain depth of 0.12 inches above the specimen supports. - Cover immersion tank to minimize evaporation. Determine the total absorption of each specimen. - Immediately after the 24-hour reading, place the specimen in an absorption tank so that it is fully submerged (per ASTM C 140). - Soak for 24 hours and determine immersed weight (Wi) and saturated (Ws) according ASTM C 140, except that when determining Ws the specimen should be blotted with a dampened cloth within 10 seconds of removal from tank, and weighed within 1 minute. Calculations and Report - Qualified (NCMA-certified) laboratory personnel who conduct such tests should also calculate the results. Testing may be conducted locally at an accredited laboratory, or samples can be transported to Euclid Chemical. Mathematical formulas are available from your Euclid Chemical representative. Euclid Chemical will accept up to 60% relative (of total saturation) absorption as being considered water repellent. Mix design and admixture dosage adjustments will be recommended before another attempt for certification is allowed.

Method 3 Spray Bar Test for Concrete Masonry Units: One full sized specimen will be required from each trial mix. This test can be conducted on smooth, polished, ground, split and/or ribbed face shells. The purpose of this test is to determine water penetration resistance (from both active spray and capillary wicking) when exposed to simulated rainfall. Method: - Prior to testing, store units in laboratory air (24+/- 8 C [75+/- 15 F]) with a relative humidity of less than 80% for not less than 48 hours. Units shall have no visible moisture prior to start of testing. Standard test kit: - Container: A suitable size plastic container having sufficient room to place a small pump and to restrict water from splashing outside of it. - Spray Bar: A ½ inch diameter PVC pipe which is 1 inch shorter than the test unit, with a PVC T section in the middle and sealed on both ends and having 1/8 inch diameter holes spaced 1 inch apart. - Connection Pipes: Required quantity of ½ inch diameter pipe and flexible vinyl hose with necessary fittings, such as PVC T section, elbow, and hose clamp to connect the spray bar into the submersible pump. - Pump: A submersible pump having a constant discharge of 2 gallons per minute throughout the testing period of 24 hours. - Bricks or pavers: 2 bricks or pavers for supporting the block assemblage above the surface of the water in the test container. - Aluminum angle & rubber sheet: Required quantity of ½ inch angle and rubber sheets to prevent water splash into the test unit.

Test Assembly: - Place 2 bricks or pavers on edge in the test container so as to support the assemblage above the anticipated water level (3-4 inches) in the container. - Aluminum angle and rubber strip may be glued to the sides and bottom face of the unit to prevent water splashing, cascading down the face and curling around the bottom edge of the unit. - Place spray bar on top of the assemblage so that the spray bar is about 1 inch from face and about 1 inch down from the top of the CMU. Face the holes to the test surface in such a way that water is impacting the face about ½ inch down from spray bar holes, about 1.5 inches from the top edge of the units and having an average angle of incidence of water spray equal to 30 degrees from horizontal. - Fill water in to the container to about 1 inch below the lower edge of the unit. - After putting water into the container, assemble the spray bar connecting in to the submersible pump with the flexible vinyl hose. - Repeat for remaining specimens (each specimen will have its own container.) Test Procedure: - Plug in pump motor and allow the spraying action to wet the face of the assemblage with continual spraying for 24 hours. - Record the dampness on the opposite side of the test face (inside core) of the unit at 15 minutes, 30 minutes, 1 hour, 1.5 hours, 2 hours, 3 hours, 8 hours, and 24 hours. - Record other observations. Reporting: Water penetration via pinholes (vs. capillary wetting) will be documented separately as they do not necessarily reflect the water repellency of a masonry unit. This is only one of three tests that, when combined with the water droplet and water uptake procedures, characterize the overall water repellency of Blocktite and/or Hydrapel-treated CMUs. There are however, limitations to the extent allowable.

RESULTS SUMMARY Date: Producer: Location: Mix ID: Admixture: Dosage: Representative: Water Droplet Test: pass fail Water Uptake Test: pass fail Spray Bar Test: pass fail Technician: Date: Customer Name and Address: Dear Valued Customer: A Water Repellency Evaluation was conducted at your (location) manufacturing facility on (date). Laboratory testing included procedures outlined in Euclid Chemical s Water Repellency Certification Program. NCMAcertified laboratory technicians have performed ASTM C-140 Methods of Sampling and Testing Concrete Masonry Units, The Water Bead Test, Water Uptake of Concrete Masonry Units, and the Spray Bar Test for Concrete Masonry Units. All tests were based on the recommendations of the Water Repellency Task Group as sponsored by the National Concrete Masonry Association. The following report details results of this testing. Based on these results, either a certificate of conformance will be issued or recommendations will be given to assist in achieving desired (passing) water repellent performance. Mix identification and design: ASTM C-140 test results: (Write Results) Conclusions: 1.) Water Bead Test: (Write results) 2.) Water Uptake Test: (Write Results) 3.) Spray Bar Test for Concrete Masonry Units (write Results) 4.) Certification (granted or denied) for Mix ID # XXX