Slide 1. Welcome to our Webinar: An Intro to the new Low Level MIP. we will begin shortly

Similar documents
MIP System Field Test for Mid-Low Level TCE

MiHpt Membrane Interface Probe + Hydraulic Profiling Tool

Chlorinated DNAPL Identification using the Membrane Interface Probe (MIP)

MiHpt Membrane Interface Probe + Hydraulic Profiling Tool

Converting Membrane Interface Probe Sensor Results Into Volatile Organic Chemical Non Aqueous Phase Liquid Distribution Information

USE OF HIGH RESOLUTION CHARACTERIZATION DATA TO OPTIMIZE SOURCE AREA REMEDIATION AT AOC 50 AT FORMER BASE FORT DEVENS

Three Case Studies: Using High Resolution Site Characterization. Patrick O Neill Vertex Environmental

Making Better Decisions: Real-Time Data Collection and Interpretation

Use of Direct Push Logging & Sampling to Characterize a Groundwater Recharge Zone

DYNAMIC INVESTIGATIONS - THE TOOL BOX. Short Course NORDROCS, September 18, 2012 Charlotte Riis, NIRAS

ZEBRA ENVIRONMENTAL MIP/EC ZEBRA ENVIRONMENTAL DIRECT SENSING SAMPLING INSTALLATION INJECTIONS

Removal of Perchloroethylene within a Silt Confining Layer Using Hydrogen Release Compound

Case Studies: Overcoming Annoying Contaminant Rebound Using Adsorptive Technologies. RemTech Banff, AB October 11, 2018 Kevin French

Site Profiles - View. General Information. Contaminants: Site Hydrology:

Developing a Site Characterization Plan

EKOS Oct 2010 COMBINING SOIL GAS SAMPLING AND MIP INVESTIGATION TO OPTIMIZE A DNAPL SOURCE ZONE CHARACTERIZATION

Enhanced Anaerobic Bioremediation Using CAP18 as a Polishing Application for CVOC Impacted Groundwater

Use of Membrane Interface Probe and Passive Flux Meters for High Resolution Site Characterization and Measurement of Mass Flux/Discharge

Electrical Conductivity & Hydraulic Profiling. The Combining of Two Subsurface Investigation Methods (With More to Come)

Efficacy of Novaerus NV 1050 System against NO 2 and Formaldehyde Gases

Site Profiles - View. General Information. Contaminants: Site Name and Location: Description: Historical activity that resulted in contamination.

ENVIRONMENTAL CONTAMINATION: Dynamic Sampling for Assessment and Remediation of Volatile Organic Compounds--The Membrane Interface Probe

Subsurface Distribution of ZVI/EHC Slurry Validating Radius of Influence. Josephine Molin, PeroxyChem October

September Prasad Kakarla, PE. In-Situ Oxidative Technologies, Inc. Lawrenceville, NJ

Prefractionator for Reliable Analysis of the Light Ends of Crude Oil and other Petroleum Fractions

System Overview. Valve oven. Restrictor. Valve. Sample in and out

In-Situ Characterization of Soil and Groundwater Contamination with MIP- and ROST-CPT

Vertex Environmental Inc.

Fuel Fluorescence Logging using the Optical Image Profiler (OIP)

In Situ Chemical Oxidation of VOCs and BTEX Plume in Low-Permeability Soils. Amit Haryani, PE, LSRP

Plume Area Treatment Example

WM 03 Conference, February 23-27, 2003, Tucson, AZ IN-SITU CHEMICAL OXIDATION OF CHLORINATED HYDROCARBONS IN THE PRESENCE OF RADIONUCLIDES

APPLICATION NOTE. UOP : Analysis of Trace CO and CO 2 in bulk H 2 and Light Gaseous Hydrocarbons by GC

Wellsite Salt Remediation: Subsoil Salinity Tool vs. Site- Specific Salt Risk Assessment? Erik J. Martin, Ph.D., DABT

SELECTED ARTICLE. Soil Analysis Using Portable VOC Analyzer, MS-200. Yoshihiko ARITA. Land Consultant/ Geological Survey Company.

PILOT PROJECT «ILE DE FRANCE»

Permeable Reactive Barriers for Petroleum Hydrocarbons

FLUTe Liner Technology in Fractured Rock An Evolution in Groundwater Characterization. Mark Higgins East Coast Field Manager Warminster, PA 18974

DoD Environmental Monitoring & Data Quality Workshop

USING TRIAD (AKA PROFESSIONAL JUDGMENT) TO TRACK A COMMINGLED PLUME

Armen Cleaners Indoor Air Quality Investigation. Jon Gulch, OSC U.S. EPA, Region V, ERB

Soil Vapor Migration Through Subsurface Utilities

Lessons from Petroleum Hydrocarbon and Chlorinated Solvent Sites Extensively Monitored for Vapor Intrusion

Design Considerations for Large Diameter Auger Soil Mixing with Steam and Zero- Valent Iron for Remediation of Chlorinated VOCs

Establishing Contact

Improved Management/Remediation of Legacy Contaminated Sites Through High-Resolution Characterization

Topics C-17 BED DOWN AREA C-17 HANGAR DEVELOPMENT PLAN. McGuire Air Force Base Restoration Program Site # SS-24. Interim Remedial Action

MDEQ PROJECT UPDATE (2015 4Q PROGRESS REPORT)

Enhanced Bioremediation Field Experience: Using Observed Half Lives in Design and Prediction

ESI SC-FAST Sample Introduction Solutions for PerkinElmer ICP-OES and ICP-MS Systems

WHITEPAPER. Key Parameter Concepts. Part 1 - Effect of Column Temperature on Bioethanol High Performance Liquid Chromatography

Triad Case Studies from the Navy. Tim Shields and Adrianne Saboya U.S.Navy PWC Environmental Department San Diego, CA

MPCA Site Assessment: Vapor Intrusion Investigation. Remediation Division Superfund Unit 1

Passive Soil Vapor Extraction (PSVE) for VOC Remediation at the Metallurgical Laboratory (MetLab) June 2005 Progress Report

Optimization of Volatile Petroleum Hydrocarbons Analysis by Automated Headspace Using Method Development Tools

Use of Zero-Valent Iron for Groundwater Remediation: Three Case Studies

DETECTORS Dry Electrolytic Conductivity Detector - DELCD. Overview

Fate and Transport of Sodium Chloride, Calcium Sulfate (Gypsum), Sodium Sulfate, and Boron in Soil: Implications for Guideline Development Work

Surfactant Enhanced Extraction to Expedite Remediation of Carbon Tetrachloride Source Zone at an Active Grain Elevator Facility Eric Dulle, PE

Fort George G. Meade. Restoration Advisory Board Meeting March 25, 2010

CASE STUDY OF THE EFFECT OF REVERSE MATRIX DIFFUSION ON REMEDIAL TIME FRAME AT A SUPERFUND SITE

Why Wait? Soil Vapor Sampling Methods and Equilibration Times

Skoog, Holler and Nieman, Principles of Instrumental Analysis, 5th edition, Saunders College Publishing, Fort Worth, TX 1998, Ch 33.

BOS 200 Remediation at a Iowa City Terminal Coralville, Iowa USA

Vertex Environmental Inc.

Site Profiles - View. General Information. Contaminants: Site Hydrology:

Cost-Effective, Accurate Environmental Investigations Using Passive Soil Gas Sampling

Customers need and want the answers Not just the hassles often associated with analytical chemistry!

In Situ, Low Temperature Thermal Remediation of LNAPL with Pesticides and Other Recalcitrant Compounds

COMPARISON OF DIRECT-PUSH ANALYTICAL INSTRUMENTATION

Advanced Reservoir Monitoring

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

In-Situ Chemical Oxidation of TCE in Clay Using Rotating Dual Axis Soil Blending Technology

ATTACHMENT 12: CDISCO Description and Sensitivity to Input Parameters

of Methane, Ethylene, Acetylene and Ethane in Water by Headspace-Gas Chromatography (HS-GC) with

CRT CRT. Carus Remediation Technologies. Simplified Science. Carus Remediation Technologies. Carus Remediation Technologies

Olefin Analyzer Solutions for Polymer Grade Ethylene and Propylene

COST-EFFECTIVE SAMPLING of GROUNDWATER MONITORING WELLS: A Data Review & Well Frequency Evaluation. Maureen Ridley (1) and Don MacQueen (2)

Comparison of EHC, EOS, and Solid Potassium Permanganate Pilot Studies for Reducing Residual TCE Contaminant Mass

SCION GC Series. The Gas Chromatographers Choice for Separations

SCION GC Series. The Gas Chromatographers Choice for Separations

Plume Cut-Off Treatment Example

Prepared by Jean Paré, P. Eng. Chemco Inc.

E N V I R O N M E N T A L I N C O R P O R A T E D

Treating 1,2 Dichloroethane in a Mixed Plume Kent, UK A Remediation Case Study on the Power of ISCO and ENA

Evaluating the Petroleum Vapor Intrusion Pathway

Sub-Slab Sampling and Analysis to Support Assessment of Vapor Intrusion at the Raymark Superfund Site

Detailed discussion of the Petroleum Vapor Database is provided in Davis R.V., 2009, LUSTLine #61 and EPA Jan

Full-Scale Permanganate Remediation of a Solvent DNAPL Source Zone in a Sand Aquifer

Site Profiles - View. General Information. Contaminants: Site Hydrology:

Rethinking Gas Chromatography

SOUTHWEST DIVISION Comparing Air Measurements and Modeling Results at a Residential Site Overlying a TCE Plume October 18, 2004

The Agilent StreamSelect LC/MS Solution: Increasing the Throughput of a Triple Quadrupole Mass Spectrometer

In-situ Remediation Lessons Learned

In Situ Thermal NAPL Remediation at the Northeast Site Pinellas Environmental Restoration Project

Alternative Cleanup Methods for Chlorinated VOCs

Volatile Organic Carbon Contaminated Site Assessment

OPTIMIZATION OF A CHEMICAL OXIDATION TREATMENT TRAIN PROCESS FOR GROUNDWATER REMEDIATION. Gary Cronk, P.E., CHMM

In-Situ Remediation of Chlorinated Solvent Source Zone using ZVI-Clay Treatment Technology

ISOTEC Case Study No. 67 ISCO TREATMENT PROGRAM: IMPACTED GROUNDWATER TREATMENT UTILIZING ACTIVATED SODIUM PERSULFATE

Transcription:

Slide 1 Welcome to our Webinar: An Intro to the new Low Level MIP we will begin shortly 1

Slide 2 An Intro to LL MIP Geoprobe Systems April 2013 2

Slide 3 Low Level MIP Technology Webinar Outline The Low Level MIP concept. Basic Operation of Low Level MIP. Field Data Examples. Question and Answer. 3

Depth (ft) Slide 4 0 5 XSD Log WS19 and Soil Sample Analytical Results WS19 TCE (µg/kg) ND TCE VOC axis (µg/kg) 10 15 20 25 30 100 300 500 µg/kg 2.0E+04 6.0E+04 1.0E+05 1.4E+05 XSD (µv) 8 This is an example of a standard MIP log run in a fine grained soil with overlaid lab analytical data for soil TCE concentrations. The soil concentrations from this location reached to just below 500 g/kg in the soil. In this particular location the standard MIP provided good signal to the TCE concentrations present.

Slide 5 5 This standard MIP-XSD log shows only a very slight response in the 17-22 range of this log while the groundwater samples from this course sand and gravel aquifer show lab results of 1-4mg/L at these depths. We knew we needed to find a way to improve our detector signal especially for areas like this.

Slide 6 6 A closer look at the XSD baseline shows very marginal signal for these concentrations.

Detector Response Slide 7 7000 Butane Response vs. MIP Flow (1999) 6000 5000 4000 3000 2000 1000 0 0 10 20 30 40 50 60 MIP Flow 7 Back in 1999, Geoprobe performed a study on how detector responses varied to MIP trunkline flow rates. It was clear that reducing the trunkline flow would provide an increased detector signal. A major problem that was seen was when trunkline flow rates dropped below 5ml/min the detector signal dropped off rapidly. Also the slower the flow rates in the trunkline the longer it takes to reach the detectors.

Sample Volume (ml) Slide 8 35 30 25 20 15 10 5 0 MIP Sample Volume vs. Flow 40 20 10 0 Flow Rate (ml/min) 8 A main reason for the increased detector signal response with lower flow rates is because the contaminant that diffuses across the membrane is now being carried in increasing lower volumes of gas thus concentrating that contaminant.

Detector Response Slide 9 12000 Butane Response vs. MIP Flow (1999) 10000 8000 6000 4000 2000 0 0 10 20 30 40 50 60 MIP Flow 9 If we look back at the graph of how flow rate affect response levels we can see that if we follow the trend line to a flow of zero our detector response should theoretically continue its upward trend until it reaches a point close to an order of magnitude higher detector response than standard MIP flow rates provide. The question was how can we achieve that without having our response fall off?

Response Slide 10 0 10 20 30 40 50 60 70 Flow Rate The idea developed: let s stop the flow behind the membrane, and then start the flow again to push the sample to the detectors!! We thought we would try to stop the carrier flow behind the membrane (in the trunkline) and then after a period of time restart the flow at a higher rate to bring the sample quickly to the detectors.

Detector Response Slide 11 12000 10000 Butane Response vs. MIP Flow (1999) Stop the flow to allow contaminants to concentrate in a small volume of gas 8000 6000 Bring the contaminants quickly to the detectors with a higher gas flow rate 4000 2000 0 0 10 20 30 40 50 60 MIP Flow 11

Slide 12 Standard and Low Level MIP Response Tests. The first feasibility test was performed by running a comparison of a standard MIP response test using the continuous flow rate of 40ml/min and then stopping the flow and restarting again. The results showed a 10x increase in signal response for the same contaminant concentration and membrane exposure time.

Slide 13 Let s design a flow circuit to do this function and put it in a box! This is the basic flow circuit that contained inside the low level controller box that allows us to start and stop the trunkline flow having no flow at the membrane during sample collection and a high flow rate to bring the sample to the detectors.

Slide 14 LL MIP Equipment MP9000 Only additional piece of equipment needed to operate MIP in low level mode. Add this controller to your existing FI based MIP system package. 14 The low level MIP controller handles all of the low level cycling of the trunkline flow and the valve switching which allows either clean carrier gas or the trunkline carrier gas to enter the sample loop. This is all handled in conjunction with the DI acquisition low level software addition.

Slide 15 LL MIP Setup TL Supply and Return Gas Lines Detector Carrier Gas Supply Carrier Gas out to Detectors FI6000 MP6505 Regulated Output MP9000 LL MIP GC1000 PID, FID, XSD MP9000 LL MIP Controller is inserted into standard FI Based MIP System. 15 When the low level MIP controller is added to the current FI based MIP system the different gas lines of the system are all plumbed through this controller. The supply gas for the trunkline coming from the MIP Controller, both the supply and return trunkline gas lines, a transfer line over to the detectors and a detector gas supply line (this one needs to be created from the gas chromatograph).

Slide 16 LL MIP Basics: When we stop the probe at depth: flow behind the membrane stops, sample concentration builds. Flow is restored and sample swept to transfer loop. Sample hand-off takes place in the transfer loop. Detector flow sweeps the sample from the loop to the detectors. Detectors never receive flow direct from the MIP probe.

Slide 17 LL MIP Operation The multi-port valve allows us to have 2 independent flow paths. Standby mode: the trunkline flow is vented to the atmosphere, while clean carrier gas from the detectors flows thru the transfer loop and back to the detectors. 17 This shows the 2 independent gas flows created by the valve system in the LL control box. Specific timed events entered in the software by the operator will determine how long trunkline flow will be stopped as well as when the valve is switched to send the sample from the trunkline to the sample loop creating the point of the sample hand-off. The most important aspect of this configuration is the constant flow that the detectors see maintains a stable baseline. If the detectors saw all of the carrier gas flow cycling their baselines would be terrible showing massive amounts of noise greatly reducing the improvement of the method.

Slide 18 These logs are 1m apart. The log on the left is a standard MIP log the log on the right is a LL MIP log. Example offset MIP-XSD logs (1m) in fine grained soils show the difference that the stoppage of trunkline flow can make in detector response magnitude. One may suspect there could be some contaminant response on the standard MIP-XSD log on the left but the LL MIP-XSD log on the right leaves no doubt where the contaminant is located.

Slide 19 Response Testing 500ppb TCE Response Test Standard MIP 500ppb TCE standard response tests performed by standard MIP method. 45sec exposure of the standard to the membrane with a constant 40ml/min flow TL carrier gas flow. 19

Slide 20 LL MIP Acquisition Software New control panels for the automated LL MIP cycling which is included in the DI Acquisition software. 20 These are images of the newly added control panel in the DI acquisition software for the automated operation of the LL cycling. The input screen is where the operator enters the cycle specific timed events. The top portion of the input screen determines how frequently to run the LL cycle as the log is advanced. In this case it will begin the LL cycle every 1ft when the probe stops forward advancement for 2sec inside of a 0.4ft window around each ft interval. The lower section of the input panel is how long the operator chooses to collect the sample at the membrane with no trunkline carrier flow, the transfer loop is loaded from the trunkline for 10seconds and after the trunkline flow is restarted the contents of the sample loop will be injected or directed over to the detectors. The output screen where the software is in the LL cycle, what the next sample interval is and what specific flow rates are within the system.

Slide 21 LL MIP Acquisition Software LL MIP Cycle Parameters: Test Standard: 500ppb TCE Detectors: XSD/PID/FID Detector Flow Rate: ~20ml/min TL Flow Rate: TL No Flow: Inject Time: Load Loop Time: ~60ml/min 45sec 51sec 10sec 21 These are the parameters that were used in the next LL MIP response tests. A 500ppb TCE standard was used and the detectors had a 20ml/min constant flow rate. The trunkline flow rate was approximately 60ml/min but was shut off for 45seconds to collect the sample at the membrane. The trunkline carrier gas will be redirected to the transfer loop for 10seconds, the final 10seconds of the inject time which is when the contents of the transfer loop get sent over to the detectors.

Slide 22 22 This is a picture of the completion of an LL MIP response test of 500ppb TCE including the response test screen and LL MIP control panel. The detector peaks seen here show the PID and XSD having very similar responses while the FID, a much less sensitive detector, has only a very slight response at this concentration.

Slide 23 Response Testing 500ppb TCE Response Test LL vs. Standard MIP Comparison of 500ppb TCE standard response tests performed by LL & standard MIP methods. 23 Low level MIP response test shows a 10x increase in the detector response magnitude over the standard MIP method.

Slide 24 LL MIP Response Testing TCE in PPB 0 25 50 100 24 This is a detection limit study done to determine the lower limit of the LL MIP system. Here a blank was run shown at ~125seconds and then TCE in ppb concentrations of 25, 50 and 100. Each of these levels shows the a good response and increases in magnitude proportionally to the previous concentration. Detection limits are determined by signal vs. noise you must have adequate detector signal many times over baseline noise. In this case the baseline noise would be what is seen in our blank however it is possible that we would not see that signal response in clean soil zones. Also just having a LL MIP controller does not mean that an operators system can see <100ppb, that is ultimately still determined by the condition of the detector system and how well maintained the detectors are. The LL controller will improve specific detector system signal by approximately an order of magnitude over whatever that system is capable of detecting by standard MIP.

Barney St. Slide 25 Field Site Examples Where Are We? Salina, Saline Co., KS x Former Gas Station Petroleum release

Slide 26 LL MIP Logs LL MIP log in hydrocarbon plume Graphs L-R: EC, PID, FID, XSD PID & FID signal 10-20 Not much XSD signal Mostly fine grained Lithology some courser grained soils at the bottom 26

Slide 27 LL MIP Logs Logs were run on the edge of a hydrocarbon plume. Overlay of: LL MIP log - red Standard MIP log - black Fine Grain Lithology 27 Here is an overlay of a standard MIP log (black) and a LL MIP log (red) that were performed within 1m of each other. The reproducibility on the EC gives us confidence that these logs were performed in very close proximity. In the next couple of slides we will take a closer look at the comparison of the PID and FID graphs of these two logs.

Slide 28 LL MIP Logs Standard MIP PID vs. LL MIP PID Response Std. MIP LL MIP Std. MIP LL MIP autoscaled synched graph scales 28 These are MIP-PID log graphs from a standard MIP log compared with a LL MIP log performed within 1m of each other on the edge of a hydrocarbon plume. Both sets contain the same two PID graphs, the standard MIP Log on the left and LL on the right are autoscaled to focus on the specific detector baseline. The baseline on the standard run log shows some contaminants from 14-19 the rest of the standard MIP-PID baseline is marginal as far as providing discernible signal over the baseline noise. The graph set on the right are the same PID graphs with the scales set at the same level which is scaled for the LL MIP log. This shows how much more robust the PID detector signal is during the LL MIP operation resulting in much greater signal to noise ratios.

Slide 29 LL MIP Logs Standard MIP FID vs. LL MIP FID Response Improved Signal to Noise Ratio = Greater Confidence Std. MIP LL MIP Std. MIP LL MIP autoscaled synched graph scales 29 These are MIP-FID log graphs from a standard MIP log compared with a LL MIP log performed within 1m of each other on the edge of a hydrocarbon plume. Both sets contain the same two FID graphs, the standard MIP Log on the left and LL on the right are autoscaled to focus on the specific detector baseline. The baseline on the standard run log shows some contaminants from 14-19 the rest of the standard MIP-PID baseline is marginal as far as providing discernible signal over the baseline noise. The graph set on the right are the same PID graphs with the scales set at the same level which is scaled for the LL MIP log. This shows how much more robust the PID detector signal is during the LL MIP operation resulting in much greater signal to noise ratios.

Scanlon Ave Slide 30 Field Site Examples Where Are We? Salina, Saline Co., KS Wall St x Former Military Airfield Site Contaminants Include Primarily: TCE, Carbon Tetrachloride

Slide 31 LL MIP Logs LL MIP Log in mixed hydrocarbon xvoc plume Graphs L-R: EC, PID, FID, XSD Hydrocarbons to 20 xvocs 20-30 Fine grained lithology 31

Slide 32 Standard MIP-XSD Log WS19 with Soil Sample Results 32 This is a standard run MIP-XSD log with overlaid xvoc lab soil results up to 500ug/kg. Good correlation between the XSD responses and the soil lab resutls. This log was performed in 2011 when validating the performance of the combined MiHpt probe.

Slide 33 WS19 Analytical Results from CAS Lab Depth CCL4 Chlrfm TCE Total X-VOC (ft bgs) (µg/kg) (µg/kg) (µg/kg) (µg/kg) 4 28 ND 28 ND 28 ND 28 ND 6 22 ND 22 ND 22 ND 22 ND 8 26 ND 26 ND 26 ND 26 ND 9 24 ND 24 ND 24 ND 24 ND 10 24 ND 24 ND 24 24 11 24 ND 24 ND 28 28 12 24 ND 24 ND 25 25 13 25 ND 25 ND 33 33 14 25 ND 25 ND 31 31 16 26 ND 26 ND 33 33 17 23 ND 23 ND 31 31 18 21 ND 21 ND 21 ND 21 ND 20 30 ND 30 ND 39 39 22 25 ND 25 ND 140 140 24 27 ND 27 ND 30 QC 30 QC 25 26 ND 26 ND 190 190 26 25 19 ND 420 445 26.1 DUP 26 17 ND 450 476 27 30 ND 30 ND 410 410 28 18 ND 18 ND 300 300 29 24 ND 24 ND 230 230 30 23 ND 23 ND 91 91 31 26 ND 26 ND 90 90 33

Slide 34 Replicate standard MIP Logs at the WS19 location EC XSD 34 When looking for comparison data for the LL MIP system we went back in 2012 to the WS19 location and performed a replicate standard run MIP log. These graphs show the EC reproducibility is good especially in the lower half of the log. The XSD also shows very good reproducibility confirming that the XSD was responding similarly as it had at this location the previous year.

Slide 35 Standard MIP LL MIP comparison MIP Logs: Std Log 1 Std Log 2 LLMIP 0-500ug/kg xvoc 35 Standard log 1 was the original WS19 location, standard log 2 was the replicate log the following year and the LL MIP XSD graph performed on the same day as standard log #2 shows the greater magnitude of the LL MIP XSD response. All three logs are scaled equally at the scale needed for the LL XSD graph. All logs have the analytical data overlaid on each XSD graph. The 30ug/kg TCE hits from 10-20 are much clearer to detect over the baseline noise with the LL MIP XSD.

Slide 36 LL MIP Logs Logs on the edge of a XVOC plume Graphs L-R: EC, PID, XSD Overlay of: LL MIP log - red Standard MIP log - black Fine grained lithology 36 These are offset standard MIP and LL MIP logs where the EC shows a high level of reproducibility confirming these logs were performed in the same area of the site.

Slide 37 LL MIP Logs Std. MIP LL MIP Std. MIP LL MIP autoscaled synched graph scales 37 Here again we are showing and standard run MIP log on the left next to a LL MIP log performed within 1m. The data set on the left is a close up view of the XSD baseline which shows marginal signal that is difficult to determine contaminant signal versus baseline noise. We might suspect there is contaminants in the bottom half of the log but it is difficult to be certain. The LL log shows very robust signal over the baseline when we are in the contaminant zone. The graph set on the right has both the standard MIP and LL MIP log scaled to the same value to show the magnitude of improved detector signal.

Slide 38 Alluvial deposits of Smoky Hill River overlying Permian Age shale bedrock Field Site Examples Where Are We? Salina, Saline Co., KS x North St 5 th St PWS15 1,2-DCA Plume 2001 Site Contaminants Include Primarily: 1,2-DCA Carbon Tetrachloride Chloroform PWS11 The study site is located in Salina, KS near the intersection of 5 th and North streets. Previous investigation by KDHE revealed an extensive 1,2-DCA plume along with smaller concentric plumes of carbon tetrachloride & chloroform. The 1,2-DCA has been impacting two local municipal wells. For our test of the HPT-GW sampler we ran a log transect across the plume (red x s). Remediation was started at the site about 3 years before our study and the plume extent appears to be changing.

Slide 39 LL MIP Logs LL MIP Log in Mixed Plume Hydrocarbon XVOC Graphs L-R: EC, HPT, PID, FID, XSD Hydrocarbons to 15 PID-FID XVOCs 35-40 & 50-60 Fairly coarse grain permeable lithology 39

Slide 40 Comparison of LL Std MIP Logs Location N-4 N-5 40 These EC and HPT graphs in these logs show a coarse grain lithology with fairly high permeability. This is an overlay comparison of Standard MIP Log (black) and LL MIP Logs (red) with left to right: EC, HPT PSI & XSD. The EC and HPT PSI display a high level of reproducibility confirming that both sets of the standard MIP and LL MIP comparison locations were performed in the same location of the site.

Slide 41 S LL MIP Logs N1 N2 N3 N4 N4.25 N5 N 41 Here is a cross section of the LL MIP logs run at the site. Most of the contaminants were seen on the north end of the cross section. This is where the groundwater sampling was taken from for lab analytical comparison.

Slide 42 Where are the Contaminants in the Subsurface? Overlay of N5 & N5A LL-MiHpt Logs EC HPT Pressure MIP XSD Detector Water Level ~31ft 32ft 35.5ft 43ft 47.5ft 51ft 55ft 59ft This is an overlay of 2 logs obtained with the recently developed combination MIP & HPT probe operated with the new Low Level detection procedure. The EC log and HPT pressure log are interpreted as discussed above. On the right is a log from the MIP halogen specific detector (XSD). This detector is sensitive to chlorinated VOCs like PCE, TCE, carbon tetrachloride, chloroform and 1,2-DCA. Above 35ft the XSD displays a baseline response, indicating essentially no contamination. However, below 35ft the detector response clearly indicates the presence of chlorinated VOC contamination. We selected preliminary sampling intervals based on the XSD response to get a range of contaminant concentrations. Of course the EC and HPT pressure logs were reviewed as well no groundwater samples between ~37-40ft due to high pressure/low permeability.

Slide 43 The HPT-GWS Log Run at the N5 Location and the Actual Sampled Intervals Corrected HPT Press. 32.0ft 35.5ft 43.0ft 47.55ft 51.0ft 55.5ft 58.45ft This is the HPT-GWS log run at the N5 location about 3ft from the LL-MiHpt log reviewed above. The EC and HPT pressure logs look very much like the LL-MiHpt log data. On the right here is the corrected HPT pressure log. This log is generated by subtracting the atmospheric & hydrostatic pressure (blue wedge, center graph) from the raw hpt pressure log, and shows the actual pressure required to inject water into the formation matrix. (This removes the baseline rise caused by hydrostaic pressure). Indicated here are the depths where we stopped and collected water samples, very close to the proposed depths based on the LL-MiHpt log.

Slide 44 Lab Results 1,2-DCA Carbon Tetrachloride Chloroform + Methylene Chloride The samples for VOCs were sent to Continental Analytical Services lab for analysis. CAS is fully accredited. (www.cas-lab.com)

Slide 45 North The Field Site Where Are We? x N5 North St 5 th St PWS15 1,2-DCA Plume 2001 PWS11 Just a reminder of where we are relative to the groundwater plume. Location N5 is at the north end of the transect. Next we will review the groundwater sample results for each HPT-GWS log location. Then we will look at a cross section of the three MiHpt logs run at the locations, across the plume.

Slide 46 N5 : Plots of Each X-VOC over XSD XSD 1.3 x 10 5 µv 1,2-DCA C-CL4 CH-CL3 0 800 µg/l This is a simple plot of the sample results for the three primary analytes at the site overlaying the MIP-XSD detector response at the N5 location. Notice that 1,2-DCA concentrations are elevated between ~35-45ft while C- CL4 and CH-CL3 concentrations are elevated from about 47-57ft.

Depth (ft) Slide 47 0 N5 : Plots of Each X-VOC over XSD 500 µg/l 1000 µg/l 10 20 30 Duplicates! N5A-XSD 1,2-DCA C-CL4 CH-CL3 Chem = ND Chem Axis 40 50 60 2.00E+04 6.00E+04 1.00E+05 1.40E+05 XSD (µv) This is another plot of the analytical results over the XSD detector response at the N5 location. This view emphasizes the presence of an upper plume of 1,2-DCA and a lower plume of C-CL4 and CH-CL3. Duplicates for each depth interval are plotted here. Only one set of duplicates (51ft) resulted in a significant RPD. Next we ll look at plots of the analytical results for the other two HPT-GWS sample logs.

Slide 48 N425 : Plots of X-VOC over XSD XSD 8 x 10 4 µv 1,2-DCA C-CL4 CH-CL3 Upper Plume Lower Plume 0-600 µg/l 0-900 µg/l 0-600 µg/l While there is only one sample from the lower plume of C-CL4 and CH-CL3 it demonstrates that the contaminants in the upper and lower plume are distinct.

Slide 49 N4 : Plots of X-VOC over XSD XSD 3.5 x 10 4 µv 1,2-DCA C-CL4 CH-CL3 Missed Sample @ 55ft 0-750 µg/l 0-10 µg/l 0-20 µg/l Because of an unexpected clay layer at 55ft (not seen on this log but is visible on the HPT-GW log) we missed getting a hot sample in the lower plume. But the XSD response demonstrates that the lower C-CL4/CH-CL3 plume is present at this south location.

Slide 50 3-Log Cross Section XSD Detector over HPT Pressure Facing West North Upper Plume Lower Plume This is a cross section displaying the HPT pressure log and XSD log for each of the 3 locations investigated. This view is facing west with north to the right. Note how the concentrations in both the upper 1,2-DCA plume and the lower C-CL4 & CH-CL3 plume decrease to the south. Also the upper and lower plumes become more distinct. Also, at the north most log there is a good bit of detector response in the sandy portion of the aquifer. Conversely as you progress south the detector response (and contaminant concentrations) are more focused around the fine grained/high pressure layers in the formation. This suggests residual contaminants are backdiffusing out of the fine grained materials.

Slide 51 Summary LL MIP Enhances detector response 10x over std MIP. Requires the FI based MIP system Successful logging depends upon sample loop timing Prove system operation with RESPONSE TESTING. Define plumes further with better signal to noise ratios Expand your MIP system capability & field time TCE @ 500ppb Std MIP -100sec LL MIP 300sec 51

Slide 52 FAQs Where should I run LL MIP logs? LL MIP should be run on plume edges where the detector signal from standard MIP is marginal and provides unclear resolution of contaminant signal and baseline noise. Also if you have a low concentration (<1ppm) VOC plume that you are concerned about the ability of standard MIP to detect it LL MIP could be your best option. Can I model LL MIP data with standard MIP data? No you will not want to do that. These data sets should be treated as separate sets. Standard MIP used to map main plume areas and source zones and standard MIP to map the low concentrations along plume edges. 52

Slide 53 FAQs How difficult is it to switch methods? If the operator has the LL Controller plumed into his system it if very easy to switch. Two gas lines with one union between them taking less than 2 minutes is what is required to switch between methods. Does LL MIP take longer than Standard MIP to run? Yes it will take a bit longer, you will need to wait for the sample to collect and to have it brought to the surface for the handoff to take place in the transfer loop before advancing to the next depth interval. TL length, TL flow and No flow time settings are the biggest factors in how much added time there will be with this method. 53

Slide 54 FAQs How Low can you see with LL MIP? LL MIP should be able to detect well below 100ppb (we showed good detection of 25ppb TCE in this webinar), however the biggest factor is how well maintained the detectors are that are coupled to the LL MIP controller. Other factors include type of contaminant and soil types. Does it require training to operate LL MIP? Yes there is a 1.5 day training that is required for operators when they first purchase the LL MIP system. This will focus heavily on the operation, how the system works and transfer loop timing. 54

Slide 55 To learn more about the Geoprobe Low Level MIP logging system or the NEW HPT-GWS (groundwater sampler) and other Direct Image tools like MIP, MiHpt, HPT, EC, CPT and PST check out this link: http://geoprobe.com/geoprobe-systems-direct-image-products You may also contact Dan Pipp (pippd@geoprobe.com), Doug Koehler (koehlerd@geoprobe.com), or Wes McCall (mccallw@geoprobe.com) at Geoprobe to learn more about these systems. Phone 1-800-436-7762 55