UC Berkeley HVAC Systems

Similar documents
Level II - Whole Building Interval Electric Data with Tenant Plug Load System

Satisfaction and self-estimated performance in relation to indoor environmental parameters and building features

LESSONS LEARNED IN MODELING UNDERFLOOR AIR DISTRIBUTION SYSTEM

Indoor Thermal Environmental Control and Satisfaction: Advanced HVAC systems and occupant satisfaction and comfort

Green California Summit It s Happening Now April 9, 2014 Sacramento, California. Porus Sam Antia

David and Lucile Packard Foundation

UC Berkeley Indoor Environmental Quality (IEQ)

Energy Reduction Strategy Through 2020

Energy Conservation Measure Development Identify, Screen, and Analyze

The correct citation for this paper is:

Matt Gudorf UCI Energy Manager

A METHODOLOGY FOR REDUCING BUILDING ENERGY CONSUMPTION

PROPOSED INCENTIVES TO REDUCE CANADA S CARBON EMISSIONS. July 2017

UC Berkeley Indoor Environmental Quality (IEQ)

University of Minnesota Duluth Civil Engineering Building

Benchmarking EPA Portfolio Manager and Energy Star Certification

Explain key terms, programs, standards ASHRAE 90.1 ENERGY DOE average energy use

Ventilation. Commercial Kitchen. What We Learned From MGM Grand Fire Airtight Buildings Benchmarking Building Energy Use Resetting Setpoints

ENGINEERING UPDATE WHITE PAPER: BUILDING PERFORMANCE METRICS. price-hvac.com. May 2013 Vol. 10

Solara: A Case Study in Zero Net Energy Design for Affordable Housing

Bullitt Center s Energy Performance

Energy Assessment Report Clayville Elementary School DRAFT October George Washington Highway, Clayville, RI DRAFT

Center for the Built Environment UC Berkeley

DISCOVERIES AT NET ZERO. Michael Leckman Diamond Schmitt Architects Chris Piche Integral Group

ASHRAE s LowDown Showdown

ENERGY MANAGEMENT IN SCHOOLS SAVING ENERGY, IMPROVING PERFORMANCE, AND REDUCING COSTS

Building Energy Analysis for a Multi-Family Residential Building (Multi V III VRF Heat-Pump System)

Energy Savings Audit

Phase-Change Wallboard and Mechanical Night Ventilation in Commercial Buildings: Potential for HVAC System Downsizing

Deep Energy Savings in Existing Buildings

PG&E Residential New Construction Program Impact Evaluation

Improving the efficiency, occupant comfort, and financial well-being of campus buildings

Energy Efficiency Analysis for a Multi-Story Research Office Building (LG Multi V Water IV Heat Recovery VRF System)

Chilled Water Thermal Storage System and Demand Response at the University of California at Merced

Building Energy Efficiency Analysis for a High School

PERFORMANCE REPORT. Building Performance Partnership. January 2011 U.S. GREEN BUILDING COUNCIL

The Energy/Comfort Nexus: making buildings work for people and the planet

SIMULATION VERSUS REALITY 4 CASE STUDIES. Anthony Calderone Aurecon, Melbourne, Australia

ENSURING A PRODUCTIVE ENERGY MODELING PROCESS

Emerging Technologies

SURNA Grow Facility: Systems Comparison - IEA

Italcementi Center for Research and Innovation

NBI Getting to Zero National Forum: A Presentation by Clark Brockman, SERA Architects September 17, 2013

EA PREREQUISITE 2: MINIMUM ENERGY PERFORMANCE

Summary Paper on Controls for HVAC

ENERGY EFFICIENT RETROFIT OF A HIGH-RISE MULTIFAMILY BUILDING

Ground-Coupled Heat Pump And Energy Storage

MAP Guidelines and Energy Efficiency and Sustainability Guidelines for MIP Reduction

KCAHE 2011 ANNUAL CONFERENCE LOW ENERGY HEALTHCARE DESIGN

The Impact of VISIONWALL High Performance Windows on the Northern Telecom Building in Ottawa, Ontario

BETA OPTION 1: PERFORMANCE RATING METHOD. Section General Information

UC Berkeley Indoor Environmental Quality (IEQ)

Leluo Zhang 1, Murali Annavaram 1, Kyle Konis 1. Abstract. Introduction

Building Energy Efficiency Analysis for a High School

D DAVID PUBLISHING. Optimizing Thermal Energy Storage Systems in the Hospitality Industry. 1. Introduction

Claire Desser Nicholas Piucci Louis Lubow ESP 167 Energy Policy Joan Ogden June 6, 2016 Energy Engineers: Earth and Physical Sciences Building

Design Standard Sustainability

23-28 = -5. Zero Net Energy Case Study WEST BERKELEY PUBLIC LIBRARY OVERVIEW. Planning & Design Approach. Measured Energy Stats

BUILDING PERFORMANCE MEASUREMENT PROTOCOLS and THEIR APPLICATION ASHRAE Triangle Chapter September 10, 2014 Raleigh, NC

Partner for Change : Energy

WBC Occupant Comfort Survey

2018 ENERGY REPORT. Mark J. Ferguson, P.E. Campus Operations & Plant Manager

EnergyPro Building Energy Analysis. Single-story School Building

Optimizing Indoor Environments for Occupant Satisfaction. Presented by: Kelli Goldstone April 2016

UC Berkeley HVAC Systems

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

ENERGIZE DENVER. a1nnual report2

EnergyPro Building Energy Analysis. Nine-story Office Building

Hello everyone, my name is Tony Cope and I m Head of Office at GPT. I want to welcome all of you here today for the kick off of our Tenant

UC Berkeley HVAC Systems

WHAT S YOUR kbtu/sf/year?

Energy Efficiency in Multi-Tenant Office Buildings

05/14/2012 THE CRIME OF IMPROPER ENERGY MANAGEMENT AGENDA

Analysis and System Design of a Large Chiller Plant for Korea, with or without Thermal Storage

ENERGY STAR Performance Ratings Technical Methodology for Medical Office Building

SUBMITTED TO: Tahoe Truckee USD Donner Pass Road Truckee, CA (530) SUBMITTED BY:

Chapter 4. Analysis of Building Energy Performance

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

The Road to Zero: State Zero Net Energy Buildings. Green California Summit Sacramento, CA April 26, 2017

POWERING. AN ALASKA VILLAGE Making the Shift from Fuel Oil to Clean Electricity

ENERGY AS SERVICES COMPANY ESCO. Jamal E. Alostaz. Projects Engineer Al-Salem Johnson Controls

BOMA s Energy Efficiency Program BEEP Course 4. No- and Low Cost Operational Adjustments to Improve Energy Performance

PHASE-CHANGE FRAME WALLS (PCFWS) FOR PEAK DEMAND REDUCTION, LOAD SHIFTING, ENERGY CONSERVATION, AND COMFORT

Water Bottling Facility

Emerging&Technologies&Summit. October&21st,&2014& &San&Francisco,&CA. Porus&Sam&Antia.

Building Energy Asset Score

CREDIT COMPLIANCE (Please complete the color coded criteria(s) based on the option path selected)

EA PREREQUISITE 2: MINIMUM ENERGY PERFORMANCE Project # SFPUC Administration Office Building

HIGH POINT NEIGHBORHOOD CENTER ENERGY MODELING REPORT CONTENTS. Goals 2. Method 2. Acknowledgements 3. Challenges and Standards 3. equest Results 4-13

UC Berkeley Controls and Information Technology

Colorado Mountain College: Sustainable Design Standards

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

The owner is Oral Roberts University, while management and leasing is handled by Trinity Corporate Real Estate Advisors, LLC.

Continual Benchmarking. Energy Management. Thomas W. Schneider Manager of Energy and Operational Efficiencies North Penn School District

ENERGY ANALYSIS AND ENERGY CONSERVATION OPTION FOR THE WAREHOUSE FACILITY AT THE HUMAN SERVICES CENTER COMPLEX DRAFT REPORT.

Xiaofen Xu, Liang Zhang, Huajing Sha, Ying Ji, Peng Xu. Tongji University, Shanghai, China

Monitoring of Energy Efficiency. Ricky Wong

N/A. ENERGY STAR Data Verification Checklist. Circle Star Plaza. 1. Review of Whole Property Characteristics. Property & Contact Information

IMPACT OF DESIGN, COMMISSIONING, MAINTENANCE AND OPERATIONAL VARIABLES ON THE ENERGY PERFORMANCE OF OFFICE BUILDINGS OVERVIEW

Actual Energy Performance of Small Office and K-12 School Buildings Designed to Meet the 30% ASHRAE Advanced Energy Design Guides

Transcription:

UC Berkeley HVAC Systems Title Case study report: David Brower Center Permalink Authors Bauman, Fred Webster, Tom Dickerhoff, Darryl et al. Publication Date 2011-04-01 Peer reviewed escholarship.org Powered by the California Digital Library University of California

INTERNAL REPORT APRIL 2011 CASE STUDY REPORT: DAVID BROWER CENTER Fred Bauman, Tom Webster, Darryl Dickerhoff, Stefano Schiavon, Dove Feng, and Chandrayee Basu Excerpted from Final Report submitted to California Energy Commission, Public Interest Energy Research Program, 2011

Confidential information not to be made public without permission from the UC Regents. INTERNAL REPORT APRIL 2011 CASE STUDY REPORT: DAVID BROWER CENTER Fred Bauman, Tom Webster, Darryl Dickerhoff, Stefano Schiavon, Dove Feng, and Chandrayee Basu Center for the Built Environment (CBE) University of California, Berkeley Excerpted from two final reports submitted to California Energy Commission, Public Interest Energy Research Program (See references for full citations) BACKGROUND The David Brower Center (DBC) is a 4-story 45,000-ft 2 office building located in downtown Berkeley, California (Figure 1). The building was completed and first occupied in May 2009. It contains lobby and public meeting space on the first floor and open plan office spaces on the 2 nd -4 th floors, which primarily house non-profit environmental activist organizations. Integral Group (formerly Rumsey Engineers) was the mechanical design engineer on the project and, working with the architect (Solomon E.T.C. WRT) and other design specialists, put together a design promoting low energy consumption. The goal of a low energy building was achieved through an integrated design process that combined thermal mass, shading, and insulation into an efficient building envelope, implemented daylighting and efficient lighting control strategies, and used a low energy HVAC system. The primary space conditioning subsystem is hydronic in-slab radiant cooling and heating, which is installed in the exposed ceiling slab of the 2 nd 4 th floors of the building. Due to their larger surface area and high thermal mass, slab integrated radiant systems use relatively warmer chilled water temperatures, making them well-matched with non-compressor-based cooling, such as cooling towers. In addition to the improved efficiency of transporting thermal energy with water vs. air (about 7 times more efficient), the building cooling energy savings are attained through the utilization of a cooling tower, instead of a chiller, to make cooling supply water. CBE selected the Brower Center as a field study site because it represents a good example of a radiant cooling system using a chilled hydronic ceiling slab design. The main goals of this case study are: 1) to assess occupant satisfaction with the building using CBE survey methods; 2) to analyze the energy consumption of this high performing building; and 3) to set up and begin a more detailed evaluation of the controls and operation of the David Brower Center and to identify strategies for improving system performance in terms of energy use and comfort.

Figure 1: David Brower Center, Berkeley, CA OCCUPANT SATISFACTION SURVEY CBE conducted its web-based occupant satisfaction survey at the David Brower Center during the period March 22 April 9, 2010. Although the building was still undergoing commissioning work on the HVAC system at the time, the building owners were interested in obtaining a baseline measure of occupant satisfaction. We anticipate conducting at least one more follow-on survey in the future to track any trends over time in response to improved control and operation of the building. Of the 150 invited occupants, 74 valid responses were received, representing a response rate of nearly 50%, which is a good representative number. Figure 2 presents the average satisfaction ratings for each of the major environmental categories addressed by the survey questions. Results from the recent David Brower Center survey are compared against the large CBE Benchmark database, containing 52,934 individual survey responses collected from over 475 buildings since 1997. The ratings are presented in terms of the 7-point satisfaction scale, ranging from -3 (very dissatisfied) to +3 (very satisfied) with 0 being neutral. Results shown for each category represent the average score for the 2-4 questions that were asked pertaining to that category (see http://www.cbesurvey.org/survey/demos2010/ for a list of typical questions). The results indicate an extremely positive response from the occupants of the Brower Center. With one exception, the ratings from DBC are all significantly higher than the CBE benchmark. For two categories, View and Blinds/Shades, there is no benchmark data because these represent two new question categories that were added for the DBC survey. Page 2 Case Study Report: David Brower Center April 2011

CBE Benchmark (N=52,934) Brower Center (N=74) Figure 2: Average satisfaction ratings by category Brower Center vs. CBE Benchmark. Survey conducted March 22 April 9, 2010. Acoustic quality represents the one category that scored lower (-1.2) than the CBE benchmark (-0.3). The tenant office space in the Brower Center is primarily open plan with many exposed concrete (hard) surfaces, especially the radiant slab ceiling used for cooling and heating. Under these conditions, it is not surprising that occupants expressed dissatisfaction with noise privacy. Figure 3 shows a breakdown of the reported causes collected from survey respondents who expressed dissatisfaction with acoustic quality. The results confirm the expected performance with a large percentage (> 80%) identifying noise and distractions from other people in the neighboring area, as well as a majority (60%) citing echoing of voices and sounds (presumably from the hard building surfaces). The David Brower Center is investigating possible mitigation measures to improve acoustic quality. If interior design improvements are made (such as installation of more sound absorbing surfaces) a future survey and acoustic measurements could be used to quantify the amount of improvement. In conclusion, despite the reported dissatisfaction with acoustic quality in the building, overall, the occupants were very satisfied. Figure 4 shows the overall satisfaction rankings for the two questions about general satisfaction with the building and general satisfaction with the workspace. For the general satisfaction with the building, the mean response (1.78) was greater than 82% of all buildings in the CBE benchmark database. For the general satisfaction with the workspace, the mean response (1.51) was greater than 78% of all buildings in the database. Page 3 Case Study Report: David Brower Center April 2011

Figure 3: Reported causes of dissatisfaction with acoustic quality Figure 4: David Brower Center overall satisfaction rankings Page 4 Case Study Report: David Brower Center April 2011

ENERGY PERFORMANCE ENERGY STAR. The Energy Star program was first developed in the 1990's by the U.S. Environmental Protection Agency in an attempt to reduce energy consumption and greenhouse gas emissions from power plants. The Energy Star program has also developed energy performance rating systems for several commercial and institutional building types and manufacturing facilities. This rating system for buildings was developed using statistical analysis of the Department of Energy s Commercial Building Energy Consumption Survey (CBECS) database comparing certain key building characteristics with source energy use. A building is rated by inputting key independent variables (e.g., gross area, number of occupants) and the monthly energy (and water) use for the past year. After weather normalizing, this data is passed through the EPA regression models to arrive at a percentile ranking relative to the comparison population. These ratings, on a scale from 1 to 100, provide a means of benchmarking the energy efficiency of specific buildings against the energy performance of similar facilities. Table 1 summarizes the Energy Star rating report obtained from the Energy Star Portfolio Manager website [EPA 2010]. The results are based on one year's worth of utility bill data (including PV generation) for the period ending June 30, 2010. The David Brower Center achieved an Energy Star rating of 99, demonstrating exceptional energy performance and well above the threshold of 75 to qualify for an Energy Star Label. The weather normalized site energy utilization intensity (EUI) was 47 kbtu-sf/yr. 1 Performance Metrics Current (Ending 6/30/2010) ENERGY STAR Label Table 1: Energy Star Rating Report for David Brower Center (August 2010) National Average ENERGY STAR Rating 99 75 50 Energy Use Intensity Site ( kbtu /ft 2 ) 47 109 147 Source ( kbtu /ft 2 ) 68 157 212 POWER MONITORING. During the past year, CBE completed an installation of power monitoring equipment that allows a detailed end use breakdown of energy by HVAC system components (e.g., air handlers, cooling tower, water pumps, water source heat pumps), and building loads (e.g., lighting, plug loads, auxiliaries). The power monitoring instrumentation includes power meters installed on all major electrical panels, and by utilizing the power reporting capabilities of the variable frequency drives (vfds) that control each of the HVAC system components, we are also able to record the power usage of each individual component. All metered panels and vfd outputs are being trended through the building management system (BMS). Power data have been collected and analyzed for the month of January 2011. Figure 5 shows average weekday power consumption profiles for the major panels and meters based on all nonholiday weekdays during January. The results show that on average, the BLDG_POWER (which does not include the tenant power) is selling power back to PG&E for a few mid-day hours due to 1 Based on total PV generation, once over-generation is determined, the EUI will be even lower. Page 5 Case Study Report: David Brower Center April 2011

the PV generation. The total building power usage is still positive at all hours because it also includes the two tenant meters (their sum is shown as tenant power ). The non-tenant power profile is shown as the sum of the bi-directional BLDG_POWER meter and the PV generation. Figure 6 presents average weekday power consumption profiles for all sub-metered panels underneath the BLDG_POWER (or BC PG&E Meter) meter. The highest profile (non-tenant power) is identical to that shown in Figure 5. The four sub-panels (VND-1, BC-MMHF1, BC-M, and BC-MHR) all exhibit fairly typical and steady day-time use profiles that never exceed 8.6 kw on any given hour. The sum of these four sub-panels is shown as the dotted blue profile. The difference between the non-tenant power and the total for these four sub-panels is shown as the green profile, which represents a variety of miscellaneous loads. Surprisingly, this miscellaneous profile reaches a maximum value around 20 kw (considerably higher than all individual submeters shown) during the morning hours before gradually decreasing to around zero by late afternoon. We are investigating the possible causes of this use profile. It seems likely to include lighting because the profile increases again in the evening, coinciding with nighttime hours during January. Figure 7 presents average weekday power consumption profiles for all HVAC equipment underneath the BC-MHR meter. With the exception of the AHUs (dashed dark blue line), all pumps and the cooling tower fan show low power usage for all hours of the day (mostly less than 1 kw). During January the cooling tower fan is turned off most of the time. The top two dotted profiles represent a comparison between the power measured at the HVAC panel (BC-MHR) and the sum of all HVAC components. We are investigating the cause of the difference. Figure 5: Average weekday power profiles, main panels, David Brower Center Page 6 Case Study Report: David Brower Center April 2011

Four Sub-Panels, total, and miss Power 50 Non Tenant Power Theatre, Kitchen, Staff, lobby, misc. HVAC sub meter: Pumps, AHUs Exhaust Fans, Garage Lights Sum of 4 sub-panels (not all) Small Heat Pumps vnd1: Lobby, conference room, courtyard, 1st Floor Power [kw] 40 30 20 10 Theatre, Kitchen, Staff, Lobby and "misc." power is the difference between the "Non Tenant Power" and the sum of the four measured sub-panels. 0-10 0 3 6 9 12 15 18 21 24 January 2011, Average Weekday Profile; Time of day [hours] Figure 6: Average weekday power profiles, sub-panels, David Brower Center Figure 7: Average weekday HVAC equipment power profiles, David Brower Center Page 7 Case Study Report: David Brower Center April 2011

NEXT STEPS CBE s field study of the David Brower Center is continuing under funding from CEC/PIER (Contract 500-08-044) and CBE Industry Partners. Although the completion of the power monitoring installation was delayed due to circumstances beyond our control, we now have an excellent sub-metering capability moving forward. CBE will be studying the controls and operation of the David Brower Center and identifying strategies for improving system performance in terms of energy use and comfort. The upcoming work will focus on key elements of the advanced system design of the building, including slab-integrated radiant cooling and heating, and underfloor air distribution. Heating operation will be studied over the next few months before switching to cooling performance during the spring and summer months. REFERENCES Bauman, F., Webster, T., Lee, K.H., Schiavon, S., Dickerhoff, D, Arens, E., Zhang, H., and Moore, T. 2011 (In press). Advanced Design and Commissioning Tools for Energy-Efficient Building Technologies. Final report to California Energy Commission (CEC) Public Interest Energy Research (PIER) Program, Contract 500-06-049. Center for the Built Environment, University of California, Berkeley. Bauman, F., T. Webster, D. Lehrer, E. Arens, H. Zhang, J. Goins, D. Dickerhoff, S. Schiavon, S. Hoffmann, T. Yu, D. Fannon, D. Feng, M. Perepelitza, and K. Zelenay. 2011. Advanced Integrated Systems Tools Development and Performance Testing. Final report to California Energy Commission (CEC) Public Interest Energy Research (PIER) Program, Contract 500-99-013, BOA-99-225-P. Center for the Built Environment, University of California, Berkeley. February. EPA. 2010. Energy Star Portfolio Manager. Environmental Protection Agency <https://www.energystar.gov>. Page 8 Case Study Report: David Brower Center April 2011