Disaggregating Electric Loads Without Metering Them

Similar documents
Giuseppe Giordano Founder & CEO

MATERIALS AND SUPPLIES INVENTORY

Aotearoa Park Shopping Centre Sample Type 1 Energy Audit

Electric Forward Market Report

Low-Hanging Fruit Simple Steps Toward Energy Effective Building Operations

Driving Efficiency with Interval Meter/Smart Meter Data. Mukesh Khattar, Energy Director, Oracle

E3T Energy. Non-Intrusive Load Monitoring. Emerging Technologies Showcase. Presenters: Krish Gomatom EPRI Chris Holmes EPRI Dave Kresta NEEA

Farm Energy Efficiency June Collin Macpherson - JCM Solutions

Low Cost Building Automation System for Small- and Medium- Sized Commercial Buildings

AEE Technical Roundtable Measurement and Verification. Alec Stevens, PE April 8, 2014

IOT SENSOR INTEGRATION IN SMART BUILDINGS FOR MONITORING & CONTROL

Establishing a Baseline, Energy Audits and Energy Star s Portfolio Manager

PacifiCorp Annual Review of DSM Programs California

AUSTIN AREA SUMMARY REPORT ON BUSINESS February 2018

Energy Data Efficiencies & Inefficiencies. Speaker: Mike Meola

The energy benefits of View Dynamic Glass

PERSONAL DAYS LETTER TO NON-BARGAINING EMPLOYEES February 19, 2018

Managing Energy Use and Cost with Integrated Metering

Allstream Centre Energy Performance Report

Farm Energy IQ. Future. Tom Manning, New Jersey Agricultural Experiment Station

State Agency Energy Savings Program

SCHOOL ENERGY WALK- THROUGH. Andy Robinson, Training and Education, SEDAC

95% U.S. Commercial Properties are less than 5,000 square meters. Vision/Problem Bringing custom energy control to small & medium commercial buildings

NSPM Rate Design Pilot

Managing Transition to Retail Competition. Lim Howe Run Managing Director, GCEO s Office Head, Strategic Investments

Using Renewable Energy in Dairy Production. Brad Heins West Central Research and Outreach Center Morris, MN

OPALCO 2015 IRP Overview. December 2015 Board Meeting

NYSERDA High Performance Development Challenge Energy Monitoring Report Hudson Passive Project

Clean Energy Extension

Marysville School District Resource Conservation Program. John Bingham Marysville S.D. Ray Burton Snohomish Co. P.U.D.

NWC District Energy Campus Energy - RFQ Supporting Documentation. April 25, 2018

Residential Real-Time Pricing: Bringing Home the Potential

California Independent System Operator Corporation. California ISO. Import resource adequacy. Department of Market Monitoring

Portland General Electric Company First Revision of Sheet No P.U.C. Oregon No. E-18 Canceling Original Sheet No. 26-1

WAKE TECHNICAL COMMUNITY COLLEGE SUSTAINABLE ENERGY PLAN. Energy Plan

Project : Power & Fuel consumption - an engineering initiative. VPS Rockland, Dwarka.

Reducing Peak Energy Demand: The Hidden Benefit of Cool Roofs

Peter Randall Solar Kingdom Ltd

Using Renewable Energy in Dairy Production. Brad Heins West Central Research and Outreach Center Morris, MN

2/17/2017. Energy Accounting & Education. Topics (Electricity) Creating Electricity

Matt Gudorf UCI Energy Manager

Smart Thermostats: Paving the Way for Smart EM&V

Surveys Show Insuladd Saves Energy!

Rainwater tank study of new homes

2001 Annual Report on the New York Electricity Markets

BEYOND O&M. Shawn Maurer SEDAC Building Energy Specialist. Smart Energy Design Assistance Center (SEDAC), University of Illinois at Urbana Champaign

18 th National Award Excellence in Energy Management Zonal Office, New Delhi

Automating the Measurement & Verification of Energy Efficiency

A New Type of Hybrid Groundwater Energy System

Department of Transportation Rapid City Region Office 2300 Eglin Street P.O. Box 1970 Rapid City, SD Phone: 605/ FAX: 605/

FORECASTING PV MARKET ADOPTION AND DEMAND IMPACTS

Greening Your Business Energy Efficiency in Buildings

Non-Intrusive Load Monitoring (Nilms) Research Activity End-Use Energy Efficiency & Demand Response

Appendix-A1 IRRADIANCE DATA

Leading Insights into Solar

The Front Lines of Industrial Energy Management

9/13/2011. Mark Hanicits, Director of Facilities and Safety, MetroSouth Medical Center. Terry Malloy P.E., Cxa, Project Manager, Teng & Associates

Procurement Summary Company Y.

Demand Response Programs. Donnie Clary CoServ President/CEO

MONITORING, TARGETING AND REPORTING (MT&R) FUNDAMENTALS AND APPLICATIONS IN THE COP PROGRAM. Robert Greenwald, P.Eng., MBA Prism Engineering g Ltd.

Traffic Department Anchorage: Performance. Value. Results.

YWCA 1503 S. Denver Tulsa, Oklahoma 5/18/2010 Performed By

SMART HVAC & LIGHTING SYSTEMS. Savings From Two Major C&I End Uses

Operation of Swimming Pool Solar Heating at Blackmount School.

Campus Annual Energy Use Report

COMPUTER SIMULATION AND EXPERIMENTAL VALIDATION OF A MODERN HOTEL ON BUILDING ENERGY CONSERVATION

Energy Savings Analysis Generated by a Real Time Energy Management System for Water Distribution

Energy Usage Reduction Program

Utility Bill Data Accounts Payable s Secret Weapon for Managing Costs and Addressing Stakeholder Questions

MoneyBack on your. total bill

Insight Report: Domestic Heat Pumps

Energy from the Earth. Geothermal Two very different methods Tides, waves, currents. Unit 12 Energy from the earth - Slide 1

The Energy and Sustainability Advantage:

Energy Program Update

a comparative study of secondary glycol and direct expansion refrigeration systems

Design Charrette. New York State Energy Research and Development Authority 17 Columbia Circle Albany, NY NYSERDA

Sales Forecast for Rossmann Stores SUBMITTED BY: GROUP A-8

Dynamic Pricing Works in a Hot, Humid Climate

ENERGY AUDIT. 123 Main Street Mississauga, Ontario. January 1, Report To: Mr. John Smith Smith Printing Company.

MACRO CRITICAL: Example Case. Standardizing Documentation of Radiology Critical Test Results The NYU Experience

Leveraging Smart Meter Data & Expanding Services BY ELLEN FRANCONI, PH.D., BEMP, MEMBER ASHRAE; DAVID JUMP, PH.D., P.E.

A Selection Guide for Resource Conservation Managers

The Future of Electricity: A Market with Costs of Zero? Marginal

Going Deep on Plug Loads: Strategies from the Bullitt Center 12 th Annual Energy/Facilities Connections (EFC) Conference 4 May 2016 Leavenworth, WA

Commissioning and Retro Commissioning Programs Title Slide for Energy Efficiency

Where Does It All Go?

METHODOLOGY The process starts with a collection of available information, continued by an audit in loco, it is

Review of PG&E Home Energy Reports Initiative Evaluation. CPUC Energy Division Prepared by DNV KEMA, Inc

Increasing Efficiencies in the Blood Supply Chain by Reducing Hospital Red Cell Wastage. Judith Chapman Blood Stocks Management Scheme, London

Enabling Efficiency in Stores to Improve the Customer Experience. Presented by Andrei Cotunoaei

Building Operator Certification Level I

Potential Impact of Biomass Burning on Urban Air Quality: Case-study of Chiang Mai

Descartes End-to-end Vision for Ecommerce

Ohio. Market Guide. AEP Columbus Southern Power AEP Ohio Power Dayton Power & Light. Residential Customers:

DERCETO : AN ONLINE PUMP SCHEDULE OPTIMISATION SYSTEM

DATE: JANUARY 24, 2018 HERITAGE VALLEY POLICY ADVISORY COMMITTEE (HVTAC) HEATHER MILLER, TRANSIT PLANNER KEY PERFORMANCE INDICATORS (KPI) REPORT

Energy Management in Plastics Processing

Role of Emerging Technologies for Energy Challenges in India

The Future of Electricity: A Market with Costs of Zero? Marginal

Carbon Reduction and Energy Optimization Strategy for one NHS Trust

Transcription:

D2: Metering and Data Information Systems Disaggregating Electric Loads Without Metering Them Sept. 26, 2013 Lindsay Audin, Energywiz Inc. www.energywiz.com

To your energy analysis toolbox, add automated load disaggregation software. Software that automatically differentiates electric loads, without using submeters or data loggers, is now available. Most offerings are focused on home and small business end users, but a few are designed for larger facilities. This is a relatively new (i.e., since 2010) product, with some vendors still in pre-production or beta test phases. Methods/claims/pricing vary, but all offer cloud-based services for Non-Invasive Load Monitoring (NILM). Such software offers a new way to remotely audit and commission energy systems, potentially finding savings more quickly and easily than standard methods. 1

Disaggregating loads may reveal options for energy cost savings. Utility billing data lacks the detail needed to disaggregate. Submetering and/or interval data are much better, but Software that disaggregates loads is now offered by 11 vendors, some since 2010. Most focus on homes & small biz, but a few are geared to more complex commercial and industrial (C&I) loads. 160 140 120 100 80 60 40 20 0 One Year Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec One Day kwh / ¼ hr 2

Perceiving loads across time helps pinpoint ops and equipment issues. Tracking interval data showed JC Penney that an off-hours lighting control system had failed, leaving the store lit all night. To cut peak demand, electric fork lifts found to be charging at 3 PM were placed on a timer/relay to start charging at 10 PM. 3

Disaggregation methods vary based on data, hardware, and software. Most rely on hardware and submetering of each circuit/load, using simple software to aggregate the loads for presentation and analysis. This may be expensive to install and is considered invasive. Newer methods use a mix of sensors, algorithms, and software to remotely differentiate, identify, monitor, and analyze loads. 4

Monthly utility data offers a crude way to pick out 1 or 2 major loads. 160 140 120 100 80 60 40 20 0 Why might usage be higher here? electric A/C Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec 5

Hourly data across a month may reveal scheduling/trending issues. What s going on here? Weekends stand out, but note the high base load, even on Sunday nights. 6

350 300 250 15-minute data across a day/month reveals ops/equipment issues. What s causing this sawtooth shape? cycling A/C compressor 200 150 100 50 0 24 hours Every building load profile is an aggregation of the profiles of various loads occurring simultaneously. 7

350 300 250 200 150 100 50 Apply asset knowledge to manually disaggregate some loads. A/C cmprs. lighting, air handlers, plug loads, elevators, etc. base load (night lighting, TX fans, circ. pumps, etc.) 0 But further separation and profiling of loads has required data loggers and/or submeters. 8

Disaggregation software uses one or more of the following methods: Sense kwh consumption in sub-interval periods (e.g., one minute or less), and IDs them via a load database. ID through database of known usage patterns based on algorithms involving probabilities (e.g., of time of use). Sense differences in AC wave form, and ID against database of known AC wave forms. Sense differences in high frequency (3 khz 100 khz) electric signal noise, and ID against database of noises. One of the above to differentiate loads, but initially ID each differentiated load using human knowledge. 9

Simple loads may be identified by wattage and/or usage patterns. Some call the pattern of a refrigerator a home s heartbeat due to its continuity and regularity. Other loads (e.g., clothes & hair dryers) stand out clearly. Loads may be identified using a database and/or human identification. Algorithms determine run time, kwh/day, and cost. ~1 kw refrigerator/freezer large electric dryer (note kw scale) hair dryer spikes 10

kwh-based systems aimed at the home energy mgt. (HEM) market: Bidgely www.bidgely.com Enetics www.enetics.com Navetas (UK) www.navetas.com Onzo (UK) www.onzo.com PlotWatt www.plotwatt.com Power House Dynamics www.powerhousedynamics.com All read energy data output from smart meter or meter strap-on devices in sub-interval periods (e.g., kwh/sec). Application is limited to homes & small biz (e.g., restaurant, 7-11, storefront retail). 11

HEM software output shows major load use/cost by month, week or day. 12

ID and differentiate complex loads via wave form and/or signal noise. At right, we see AC wave forms for a CFL, a freezer, and a dishwasher. Disagg firms use proprietary wave form databases that grow as they add users. CFL Frzr Dshwr The starting/stopping of a load, or even flicking a switch, may also create a unique noise signal, easily differentiated each time it appears. But both methods may still require human insight and knowledge to initially identify each load. 13

Software vendors using those sub-cycle / signal ID methods: Load IQ www.loadiq.com Verdigris www.verdigristech.com Verlitics www.verlitics.com Wattics (Ireland) www.wattics.com WattSeeker (France) www.wattseeker.com All involve installation of a few CTs hooked up to an on-site data collector that reads in msec or μsec durations. ID is via AC wave patterns or distortions, or signal noise signatures, at startup or after loads are running normally. 14

C&I software outputs show more detail. Services may include load analysis. Here s a week of data. Each color-coded load is separately profiled. The black line is total load. Below are loads across a day, again color coded, but now also aggregated to show contributions to peak demand. Software is sophisticated and more flexible. 15

FAQ How new/proven are these products? How much load is accurately disaggregated? Smallest load that can be dissaggregated? How long/difficult to install and start to use? Can it discriminate among simultaneous start-ups? How about variable loads (e.g., VSD, dimming)? Are any systems compatible with my EMS? How is it priced? What s the cost for a 100,000 SF office building? 16

My Assessment (as of 9/13) The HEM/small biz systems are useful, but so basic in output and methods as to be limited to facilities with perhaps 5-10 loads. Systems focused on C&I loads are in beta (or other) stages with only a few operating sites in the US. European firms may be more established, but offered only minimal (or no) case studies. Bottom line: by mid-to-late 2014, all C&I offerings may be ready for rollout. They show potential, but costs & abilities vary. Question all savings & payback claims. 17

Thank you for your time and attention. Energywiz Inc. greatly appreciates the help provided by these suppliers and organizations in developing this presentation: Load IQ Pecan Street Research Institute PlotWatt Verdigris Technologies 18