Shop-Window Lighting in the Mediterranean Countries: The Use of Sun to Improve Visual Appeal and Reduce Energy Demand

Similar documents
INTEGRATION OF LIGHTING PERFORMANCE INDICATORS INTO A DASHBOARD FOR DAYLIGHTING ASSESSMENTS. Beatriz Piderit 1, Daniela Besser 2

ResearcH JournaL 2011 / VOL

COMPARATIVE EVALUATION OF SIDE-DAYLIGHTING STRATEGIES

New solar shading system based on daylight directing solar glass lamellas

Enhancing visual comfort in classrooms through daylight utilization

DAYLIGHTING SIMULATION AS MEANS FOR CONFIGURING HOSPITAL INTENSIVE CARE UNIT WINDOWS UNDER THE DESERT CLEAR SKIES

Design and retrofitting of a hybrid building in Athens

DYNAMIC DAYLIGHT SIMULATION AND VISUAL COMFORT SURVEY IN MEDITERRANEAN CLIMATE. CASE STUDY IN OFFICE BUILDING.

An assessment tool for selection of appropriate daylight solutions for buildings in tropical and subtropical regions:

Energy Saving Benefits of Daylighting Combined with Horizontal Exterior Overhangs in Hot-and-Humid Regions

DAYLIGHTING PERFORMANCE OF TOPLIGHTING SYSTEMS IN THE HOT AND HUMID CLIMATE OF THAILAND

Utilization of Combined Daylighting Techniques for Enhancement of Natural Lighting Distribution in Clear-Sky Residential Desert Buildings

Daylight has been a primary source of lighting in buildings. Daylighting improve indoor environmental quality and visual comfort. Moreover, it reduces

Solar Shading System Based on Daylight Directing Glass Lamellas

Assessment of shading devices with integrated PV for efficient energy use

EE2E045 A Calculation Method on the Energy Demand of Urban Districts

The Assessment of Advanced Daylighting Systems in Multi-Story Office Buildings Using a Dynamic Method

A STUDY OF DAYLIGHTING TECHNIQUES AND THEIR ENERGY IMPLICATIONS USING A DESIGNER FRIENDLY SIMULATION SOFTWARE

COOLING LOADS AND OCCUPANT COMFORT IN HIGHLY GLAZED BUILDINGS AND THE EFFECTIVE EVALUATION OF WINDOW RETROFITS

Young Cities Research Briefs 07 Architectural Energy Efficiency

Poor distribution & glare

An Experimental Study for the Evaluation of the Environmental Performance by the Application of the Automated Venetian Blind

Bioclimatic Design Approach Integration into Architectural Design: a Library Case Study

Daylight Efficiency Prediction of Courtyard vs. Conventional Building Models Using Simulation Tool under Specific Climate Conditions

AUTOMATION SYSTEM FOR LIGHTING CONTROL: COMPARISON BETWEEN DATA RECORDED AND SIMULATION MODEL

The effect of shading design and control on building cooling demand

Daylight Harvesting in Tropic

PARAMETRIC MODELLING FOR THE EFFICIENT DESIGN OF DAYLIGHT STRATEGIES WITH COM- PLEX GEOMETRIES

Daylighting Design 12 th Annual Building Codes Education Conference March Bozeman, MT Jaya Mukhopadhyay, Co-Director, Integrated Design

5.0 Daylighting Analysis (Breathe Study)

MAKING DAYLIGHTING WORK IN SCHOOLS

Guidelines for Design and Construction of Energy Efficient County Facilities

additional cooling energy consumption. Because the thermal resistance of windows has always been a weak point, even with vacuum glass or low-e glass,

171: An urban office designed for the southern Brazilian climate

Ventilated Illuminating Wall (VIW): Natural ventilation and daylight experimental analysis on a 1:1 prototype scale model

Effect of a Window Shade on Home Energy Use

The lotus flower: biomimicry solutions in the built environment

Energy and Lighting Performance of Buildings in the Neighbourhood Ciudad de los Angeles, Before and After Refurbishing.

SAGEGLASS VARIABLE TINTED GLAZING INPUT SHEET FOR DIAL+ SOFTWARE

Thermal comfort in housing under solar obstruction derived from high building in urban renewal areas.

An enhancement of the daylighting from side-window using two-section venetian blind

Sustainable lighting design in school buildings

Daylighting for Visual Comfort and Energy Conservation in Offices in Sunny Regions

Analysis of Indoor Luminous Environment and Power Generation by Roll Screen and Venetian Blind with PV Modules

A STUDY OF WALL SURFACE TEMPERATURE VARIATIONS FOR HOUSING IN MODERATE CLIMATES

Research Article DevelopmentandPerformanceEvaluationofLightShelvesUsing Width-Adjustable Reflectors

Available online at ScienceDirect. Energy Procedia 78 (2015 ) th International Building Physics Conference, IBPC 2015

INTUITIVE AND OBJECTIVE APPROACHES TO DAYLIGHTING A NEW ENGLAND ELEMENTARY SCHOOL Michael Rosenfeld 1

Iv. Absolute Towers, Ontario, Canada Architect: Yansong Ma

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

The only constant aspect of Technology is,.change! Sustaining Technology! MATERIAL. Sustaining Technology in Glazing

475: DAYLIGHTING DESIGN FOR LOW ENERGY BUILDINGS IN SOUTH ITALY

The Effects of Light Shelf on Climate-based Daylight performance in Tropics- A Case Study

SIMULATION-ASSISTED DAYLIGHT PERFORMANCE ANALYSIS IN A HIGH-RISE OFFICE BUILDING IN SINGAPORE

Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 1

ARCH-MEDES (I) CONSULTANTS PVT. LTD. Green Park Delhi

URBAN MORPHOLOGY AND ENERGY PERFORMANCE: THE DIRECT AND INDIRECT CONTRIBUTION IN MEDITERRANEAN CLIMATE

optimize daylighting Opportunities

HOW CURRENT TRENDS IN THE DESIGN OF FACADES INFLUENCE THE FUNCTIONAL QUALITY OF INTERIOR SPACES

The Double Glass Skin Façade: a sustainable option for the Curtain Wall in Mediterranean Climate Countries?

Parametric Louver Design System Based On Direct Solar Radiation Control Performance

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

GARFIELD COUNTY, COLORADO

ACOUSTIC BEHAVIOR OF ACTIVE GLAZING FAÇADES WITH CIRCULATING WATER CHAMBER

The energy benefits of View Dynamic Glass

SKYLIGHT DESIGN PERFORMANCE EVALUATION METHOD DEVELOPMENT WITH THERMAL AND DAYLIGHT SIMULATION

Experimental study on optic and thermal performance of solar control films

COMPARISION OF FIVE WINDOW SHADE STRATEGIES

IMPACT OF OCCUPANT BEHAVIOUR ON LIGHTING ENERGY USE Heverlee, Belgium Corresponding address:

A Pilot Study for the Determination of the Energy Saving Potential in a Typical School Building by Utilization of Daylighting

User Interactions with Environmental Control Systems in Buildings

Modeling Energy Consumption Effects of Glazing

Investigation of a Solar active glass facade

Veronica Garcia-Hansen Gillian Isoardi Michael Hirning John Bell

CONTROLITE. Intelligent Daylighting System FACADE SKYLIGHT

ENERGY EFFICIENT DESIGN OF SIDE-WINDOW FOR DAYLIGHTING APPLICATION IN THAILAND. S. Chungloo, B. Limmeechokchai and S.

447 - Thermal Performance of Residential Buildings in Lisbon with Large Glazing Areas

DYNAMIC FACADE. BUILDING ENERGY EFFICIENCY REHABILITATION.

ADVANCED FAÇADES AND HVAC SYSTEMS: PRELIMINARY RESULTS OF FULL-SCALE MONITORING

Role of daylight in the existent and future French building regulations

Evaluating the Building Performance of the Center for Promotion of Science in Block 39 in Belgrade, Serbia

AN ADVANCED GLAZING CASE STUDY FROM THE IMAGE PROJECT

International Journal of Advance Engineering and Research Development

Heating, Cooling, Lighting: Sustainable Design Methods for Architects

546: High Altitude Design, Optimising Residential Architecture in the Alborz Mountains, Iran

Climate Analysis. Daylighting uses solar angles, cloud cover/precipitation, and context. Temperature. Humidity. Precipitation. Wind.

Aalborg Universitet. CLIMA proceedings of the 12th REHVA World Congress volume 2 Heiselberg, Per Kvols. Publication date: 2016

Sustainable Urban Block Design through Passive Architecture A tool that uses urban geometry optimization to compute energy savings

Irvine CA MAE ROW ROW ROW. Office Lighting Plan. Page 93

Energy rehabilitation of social housing for rent, as demonstrator in the LIFE New4Old Project

EXTERNAL SHADING DEVICES

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

690: Form Follows the Sun: Hill County SEZ Office Complex

THERMAL MASS CHAPTER 6. Understanding thermal mass. Seasonal effects of thermal mass

consumption. As the first step of calculating indoor energy consumption, this study investigated the net radiation heat gain of building exterior surf

DAYLIGHTING DESIGN IN A LOW ENERGY BUILDING

Comparative Performance of Internal Venetian Blind and Roller Blind with Respects to Indoor Illumination Levels

EVALUATION OF VENTILATION STRATEGIES TO REDUCE OVERHEATING IN A TYPICAL METAL CLAD BUILDING WITH IN- PLANE ROOF-LIGHTS

The Teatinas of Lima: Energy Analysis and Possibilities of Contemporary Use

Transcription:

Athens Journal of Mediterranean Studies July 2015 Shop-Window Lighting in the Mediterranean Countries: The Use of Sun to Improve Visual Appeal and Reduce Energy Demand By Elena Anagnou Helena Coch Isabel Crespo The present study deals with the potential reduction of energy consumption for lighting of shop window displays in the Mediterranean countries. Urban commerce has a very high impact on economics and it is a highly energy-consuming sector. Light has the power of attracting people s attention, which is one of the goals of the trading and selling activity and very high illuminance levels are usually recommended. In the Mediterranean areas, where daytime lasts for many hours, commercial activity takes place mainly under sunshine conditions and shop windows frequently fail to fulfil their main corporative goal, namely the unobstructed observation of the products exhibited. The necessary increase of artificial lighting illuminance levels to accent interior light conditions, due to extremely high-luminance urban surroundings, leads to an important increase of energy consumption. Nevertheless, the results are generally very poor, due to reflections and other kinds of visual problems. The present study evaluates the visual and energetic benefits of an innovative passive design that obstructs solar rays and redirects them into the interior of the shop window scene. A scale model of this new design confirms the visual benefits produced by its use, via the different luminance maps tested. Keywords: display lighting, passive design, saving energy, shop-window. Introduction The image of the Mediterranean cities, where climate favours exterior human activities, is conserably affected by urban commerce and storefronts. Being a fundamental element of the commercial process, a proper visual presentation of shop windows is crucial. Lighting contributes to the creation of a corporate identity, ideally, it assists the production of the image desired by the trader and together with other components of the design it contributes to sales promotion (Rea, 2000). The present study analyzes the visual inconveniences of window displays associated with the Mediterranean climate and how they are or should be dealt with, so that the aesthetic and commercial function of shop windows will not be inhibited. Researcher, Polytechnic University of Catalonia, Spain. Polytechnic University of Catalonia, Spain. Polytechnic University of Catalonia, Spain. 249

Vol. 1, No. 3 Anagnou et al.: Shop-Window Lighting in Mediterranean Countries... In the Mediterranean Cities, the Shopping is Combined with Promenade under the Sun In Mediterranean climates, the temperature favours urban commerce, since duration of daily solar radiation is extensive and solar intensity is prevalent throughout the whole year. For example, in one of the most commercial districts of Barcelona, Eixample, the urban scenery offers optimal conditions regarding the use of the mild climate of Barcelona; at pedestrian level the broad avenues are offered to enjoy the sun and good weather and combine promenade with shopping (see figure 1). Figure 1. In Mediterranean Cities like Barcelona, Urban Fabric and Mild Climate Favour Urban Commerce However, although in the Mediterranean countries shop-window glazing mainly takes place under sunlight, shop-window light scenes are basically designed for their night presentation. This fact has significant inconveniences for the shop-window glazing procedure that derive from the exposure of window displays to varying light conditions in the outside environment; due to the very high level of exterior illuminance, the visual goals of window displays are often impeded. High Energy Consumption yet Poor Visual Outcome The lighting design of window displays is required to ensure visual comfort and good vision of the products exhibited (Anagnou and Coch 2012). In order to do so, adequate illuminance levels and luminance contrasts must be secured. A recommended value for luminance ratio between the illuminated object and its surrounding area is 3:1 (Carillo et al. 2010). Regarding illuminance values, certain studies prove that a higher illuminance level implies that more passers-by are attracted by the shop windows (Carillo et al. 2010). As a result, the consumption of energy for the lighting of window displays is rather high (Freyssinier et al. 2006). In Catalonia, window display 250

Athens Journal of Mediterranean Studies July 2015 lighting constitutes 11.2% of the total energy consumption for the lighting of a typical store (Institut Catalá d Energia, 2008). However, despite the high energy consumption, visual inconveniences insist; during the research discussed in this paper, a study of a representative sample of shop windows of the city of Barcelona has been performed analyzing their visual results. The basic tools of this analysis have been the luminance maps and evaluation, via computer application, of the odds of glare. The study has confirmed and identified the main inconveniences that can impair the visual result and, therefore, the commercial purposes, during daytime hours. Specifically, the most frequent problems are: failure to reach the appropriate contrasts for the projection of exhibits, glare and annoying reflections. Indeed among the analysed stores, the visual presentation of 65% of them failed to reach a contrast of 3:1 between all exhibits and their surroundings, as well as 65% of them failed to avoid annoying reflections (see Figure 2). In addition, the conducted analysis confirms that the commercial storefronts mostly affected by such inconveniences are those receiving direct solar incidence, weather in the actual presentation of the window or in immediately adjacent areas. In order to help face these visual disadvantages resulting from very high levels of exterior illuminance, a remedy often applied is to increase artificial illuminance projected during the day, in contrast to the one projected overnight. However, the intensity of sunlight in the Mediterranean countries is so high that artificial lighting cannot compete with the natural one making it vain for any power to increase during the day, along with the corresponding energy additional charge this practice entails. This study instead evaluates the visual and energetic benefits of an innovative passive design. 251

Vol. 1, No. 3 Anagnou et al.: Shop-Window Lighting in Mediterranean Countries... Figure 2. (a) Graphic Showing Percentage of Commerce Failing to Reach Contrast 3:1 Between All Exhibits and their Surroundings, Plus An Example (B) Graphic Showing Percentage of Commerce with Presence of Annoying Reflections, Plus An Example Methodology The present research evaluates the visual and energetic benefits of a passive design that obstructs solar rays and redirects them into the interior of the shop window scene. In fact, the improvement of the quality of the observation of exhibits during daytime is assessed, along with the possible reduction in energy consumption. Selection of the Case The center of Barcelona, Eixample, has been considered ideal for this study because it is a district with a significant concentration of commercial activity and it has a structure that favours sun-lighting of its wide streets and building facades; in addition, the regulated matrix of its urban fabric facilitates such a study and allows the generalization of results across its surface (see Figure 3). 252

Athens Journal of Mediterranean Studies July 2015 Figure 3. The Regulated Matrix of Eixample District Source: https://www.google.com/maps/preview (subsequently elaborated image) A segment of the Eixample has been modelled in a simulation program that incorporates solar trajectories (Heliodon). After analyzing the data obtained during the study, concerning the time of exposure to solar radiation and the percentage of illuminated surface is observed as expected, that: a) The facades of the ground floor facing south are the most affected. b) The most detrimental period, when higher percentage of the surfaces of the ground floor is exposed to sunlight despite the obstruction of the urban fabric, is summer (see Figure 4). Furthermore, it is the period with the highest average monthly hours of sunshine in Barcelona. Figure 4. a) Design and Emissivity Percentage Isochronous of South Facades. b) Percentage of Illuminated Surface, Evolution throughout the Year 253

Vol. 1, No. 3 Anagnou et al.: Shop-Window Lighting in Mediterranean Countries... Development of the Passive Design Component A typical window display of Barcelona has been selected among the sample observed, referred in introduction, that is about four meters high, one meter wide and facing south. Based on the solar diagram of the city, several design tests have been performed in order that, when a system of reflective surfaces is incorporated in a typical window facing south, it could make the most of the solar incidence during the most unfavourable conditions; the latter being summer solstice, as confirmed with Heliodon. The design that is finally proposed here (see Figure 5), is based on two successive light reflections. Rays that fall upon the first and curved surface will be reflected symmetrically around the axis joining the point of incidence and its centre of curvature (Peoglos et al. 2004); subsequently, they will be cast on the plane surface and will be reflected towards the interior of the scene. Figure 5. (a) Geometry of the Component Proposed (b) Conduction of Natural Light in the Interior of the Scene Development of the Scale Models Two scale models of the window analyzed, the one being independent of and the other one based on the proposed system, have been developed. As in the present study the effect of chromatic contrast is not analyzed, all the components of the scene have been chosen to be of soft and slightly contrasting colours (see Figure 6). 254

Athens Journal of Mediterranean Studies July 2015 Figure 6. Model Based on the System Proposed The dimensions of the models have been adjusted to the artificial lighting projected, giving special care so that both the area of the surfaces and the luminous flux they receive, would be correctly scaled. In each one of the models two LED sources have been placed above two mannequins and 30cm of led stripe above the background of the scene 1. In order to simulate the illuminance of the real window display, after measuring the luminous intensity of both real and model light sources, and applying the basic laws of photometry, the appropriate scale of the model has been defined to dm=0,09dr 2. A potentiometer has also been connected to the led stripe, so that its intensity could be dimmed and, in this manner, possible reduction of energy for vertical illumination could be evaluated. Simulation of the Desired Exterior Light Conditions The study took place in Athens on December 10, during the time of zenith. In order to simulate the summer solstice in Barcelona (72 during the zenith) the table where each model was placed has been rotated through 43 (see Figure 7) equal to the difference of solar altitude on December 10 in Athens (29o during the zenith). Furthermore, in order to obtain an overall assessment of the results for the entire year, a simulation of the equinox and winter solstice in Barcelona (49º and 26º correspondingly during the zenith) were simulated rotating the table through 20º, and -3º correspondingly. 1 A Prolight PM2B 3LxS-SD-3W above each mannequin and a power LED a strip led of 40W type 3528 for vertical illumination. 2 d M = dimensions of the model, d R = dimensions of the real window display 255

Vol. 1, No. 3 Anagnou et al.: Shop-Window Lighting in Mediterranean Countries... Figure 7. Simulation of the Desired Exterior Lighting Conditions by Rotating Through 43 o the Table Where the Model Is Placed Evaluation of Visual Differentiation, Depending On the Existence of the Proposed System The comparison of the visual outcome of the two different models has been realized via the observation of photographs and their equivalent luminance maps, in addition to the observation in situ. The comparison took into account the following visual inconveniences: 1. Annoying reflections. 2. Achievement of 3:1 contrast between products and their surrounding area. 3. Glare. In order to compare the possibility of glare in every situation, the Radiance based tool, called Evalglare, which evaluates that possibility through the daylight glare probability index, DGP (Wienold 2009) has been used in addition to the luminance maps. Results and Discussion The comparison of the visual result of the two scenes, the one independently of and the other one based on the proposed design, has resulted the expected improvement. Via the observation of the photographs and the luminance maps derived from them, the positive effect of the redirection of the sunlight into the scene is appreciated (see Figure 8). 256

Athens Journal of Mediterranean Studies July 2015 Figure 8. (a) Photograph and Luminance Map (b) DGP Index. Comparison of the Two Models, without (left) and with (right) the System Proposed Specifically, regarding the model of the proposed system, the following parameters are observed: 1. The reflections on the glass of the scene are significantly moderated compared to the model without the system. 2. The desired contrast of 3:1 between the products and their surrounding area is achieved, avoiding thought high contrasts dued to solar incidence on them. 3. Less areas of high luminance that can dazzle are generated comparing to the model without the system. The comparison of DGP index for the two cases is indicative. Concerning the rest of the seasons, the design proposed has no negative effect. On the contrary, the effect against the inconveniences of glare and annoying reflexions are positive throughout the year. Following, in order to evaluate the possibility of energy reduction, the power of the background lighting of the scene has been decreased in the case of the design proposed; applying the 1/3 of the illuminance projected before, the result has been again positive (see Figure 9). Even with a drastic reduction of power applied when the proposed design is incorporated, regarding the model of the proposed system, the following parameters are observed: 1. The 3:1 contrast is once again achieved. 2. The generated reflections are significantly lighter. 257

Vol. 1, No. 3 Anagnou et al.: Shop-Window Lighting in Mediterranean Countries... 3. Probability of glare is smaller. All these effects were expected, since solar light intensity that is introduced in the scene is the one increasing significantly the illuminance in it; not artificial lighting. Figure 9. (a) Photograph and Luminance Map (b) DGP index. Comparison of the Two Models, without (left) and with (right) the System Proposed When In Addition Wall Wash Lighting Is Reduced to 1/3 Conclusion This paper results in a passive design proposal that can offer very positive effects on the visual result of shop windows, improving the quality of their observation, thus fulfilling their commercial visual goals during the day and, in addition, reducing energy consumption. In the Mediterranean countries, the inability of artificial lighting to compete with high solar illuminance makes it vain for any power to increase during daytime, along with the corresponding energy charge this practice entails. Instead, the increase of interior illuminance levels of shop windows by using the very illuminance of the sun may improve the visual outcome and reduce energy consumption for the lighting of the window display. The positioning of the proposed design of sunlight redirection, with the dual effect of both obstruction of its incidence and the benefit of its intensity to increase illuminance in the interior of the shop window, has very positive effects on its visual presentation, especially in terms of reducing annoying reflexions and the possibility of glare. Moreover, these effects are valid even 258

Athens Journal of Mediterranean Studies July 2015 when reducing the installed power for the lighting of the background of the scene, thus making possible, in combination with the use of sensors and resistors, further reduction of energy consumption for the lighting of the display window. This new lighting passive system results in a very simple, effective and low cost solution that can be easily applied in existing shopwindows, with considerable visual and environmental benefits when incorporated in the highly energy-consuming display windows. References Anagnou E, Coch H (2012) Escaparates de Barcelona: El impacto del alumbrado comercial exterior a la ciudad [Barcelona windows: The impact of outside commercial lighting to the city]. Luces Cei, Febrero 45: 18-24. Carillo C, Diaz-Dorado E, Cidrás J, Bouza-Pregal A, Falcón P, Fernández A, Álvarez- Sánchez A (2013) Lighting control system based on digital camera for energy saving in shop windows. Energy and Buildings 59: 143 151 Freyssinier JP, Frering D, Taylor J, Narendran N, Rizzo P (2006) Reducing light energy use in retail display windows. Sixth International Conference on Solid State Lighting. San Diego: Proceeding of SPIE. Institut Catalá d Energia (2008) Caracterització del consum energétic en els establiments del sector de pimes de comerç i serveis de Catalunya [Characterization of energy consumption on the premises of the SME sector of trade and services of Catalonia]. Barcelona. Peoglos B, Raptis I, Christodoulides C (2004) Optical Instruments. In B Peoglos, I Raptis, C Christodoulides, Experimental Physics Techniques. Athens: National Technical University of Athens 3: 39-82. Rea M (2000) IESNA Lighting Handbook: Reference & application. 9th Edition. New York: Illumination Engineering Society of North America. Wienold J (2009) Dynamic daylight glare evaluation. IBPSA Conference. Glasgow: Building Simulation: 944-951. 259

Vol. 1, No. 3 Anagnou et al.: Shop-Window Lighting in Mediterranean Countries... 260